cv of AM
-
Upload
gulfam-shahzad -
Category
Documents
-
view
323 -
download
0
Transcript of cv of AM
-
8/12/2019 cv of AM
1/3
OBJECTIVE
To join a dynamic and progressive organization offering ample opportunities for diversified experience, and seeking
a position which will allow for continued professional growth, offering an environment in which advancement is
based on strength of individual contributions to the realization of organizational goals.PERSONAL I NFORMATI ON
AHSAN MAJEEDFathers Name: ABDUL MAJEED
Date of Birth: 26-06-1978
Domicile BWP (Punjab)
Nationality: PakistaniMarital Status MarriedReligion: Islam
CNIC No: 31203-7410249-9Permanente Address: Ward#10, ST#7 Ghareeb Mohalla Hasil pur.Contact No: 0346-4116542
ACADEM IC RECORDS
Degree/Certificate Years Division Board/University
Matriculation 1994 1st B.I.S.E, BWP
B-Class Boiler Engineering 2007 --------- Poonch House Punjab Lhr
A-Class Boiler Engineering ---------- continue Poonch House Punjab Lhr
D.A.E
(Mechanical Technology)2008--- continue P.B.T.E Lahore
LATEST EXPERIENCE
Engro foods supply chain (Pvt) Ltd.
Utilities Operations (Compressor, RO, CT), Boiler, DGs, ETP, Fir Fighting system and Steam Turbine. Training is continuing of ST and DGs.
I joined EFSL on 2010 and I have been the part of the Commissioning and erection Team. And still I am working there. I givefeedback for the modification of the system to make it good and reliable.
COMMISSIONING
Boiler:During Pre-Commissioning I performed the tests with my team of{(Trial runningof motors on solo run and on loadbased on Vibration and Temperature parameters, Positive Pressure test of Gas path, Negative Pressure test of Gas path, Dryout (backing of refractory), Boil out, Steam test, Flush out of Economizer, Boiler, Deaerator, Condensate tank, Treated
Water tank and related Parts, Loop testing of electronic circuit, PLC, And Inter Locking)} and Design review of Highpressure steam Boiler.
RO: During Pre-Commissioning I performed the tests with my team of {Whole the was flushed out. MM, Bag Filter,Cortege Filter and RO Vessels, Loop Test, Trial running, Adjusting of Parameters Chemical treatment, and product QualityTests.}.
DGs:During Pre-Commissioning I performed the tests with my team of{Flushing of Piping loop,
Steam Turbine: During Pre-Commissioning I performed the tests with my team of {Steam blowing of piping loop,Flushing of Oil circuit, Over speed Tripping test, Flushing of Condenser line loop, Loop testing (Electrical, Electronic,Hydraulic and PLC system), Interlocking and safety tests, Vibration, Displacement and Temperature parameters test, Load
test via Load Banker.}
-
8/12/2019 cv of AM
2/3
Compressor: During Pre-Commissioning I performed the tests with my team of {Air blowing of all loops of compressedair system, Air blowing of Air Dryer system, Loop testing (Electrical, Electronic and PLC system), Interlocking and safetytests and Load test}.
These all mentioned test were Performed on OQ and IQ bases which were analyses by the Laboratories also.
ETP;
PROFESSIONAL EXPERIENCE(OCL THERMAL POWER HOUSE I PPS)
The 2ndBiggestproducer of sodium carbonate&Bicarbonate in Pakistan, Having Capacity of 450MT/day Plant has following Areas, Absorptions,Carbonation, Calcination, Distillation, Compression, Kiln, and Water Treatment Plant & Utilities Area Here I Was working as a Shift Engineer Utilities.
My Areas of Responsibilities
Boilers High pressure & low Pressure (FBC-CFBC-and Grate type Coal fired)
Steam Turbines (5MW back pressure Extraction type, 3MW back pressure type)
Water Treat Plants (DM, Sodium Zeolite, Hot lime and Waste treat ment Plant)
Field Area of Whole UTY
Exhaust Gasses treatment (Desulfurization)
Responsibilities as a shift engineer
Preventive Predictive maintenance of boilers, Water treatment plant & other related Areas. Emergency Handling Regarding to any rotary Equipments, Plant Shut Down, Normal and Emergency any Type of Trouble
Shooting Observing Operation Conditions such as vibration bearing temperature lab analysis reports and other operational parameter. Excellent organizational skills with an attention to detail. I analyze problem and situations and construct logical, practical and
consistent solution. Co-ordinate with discipline managers and engineers /operator to ensure that all equipment meet the required safety specification and
standard. Sound understanding of preventive/maintenance, techniques and practices. Emergency Shutdown/Startup of power house, Boiler etc. Operational Experience water treatment Plant RO, DM, Hot lime, Sodium Zeolite etc.
My Skills
Excellent organizational skills with an attention to detail. I analyze problem and situations and construct logical,practical and consistent solution.
Co-ordinate with discipline managers and engineers /operator to ensure that all equipment meet the required safetyspecification and standard.
Sound understanding of preventive/maintenance, techniques and practices. Emergency Shutdown/Startup of power house, Boiler etc.
Operational Experience water treatment Plant RO, DM, Hot lime, Sodium Zeolite etc.
Total experience 13 years approximately.
COMPUTER SKILS
Basic Knowledge of Computer.
-
8/12/2019 cv of AM
3/3
REFERENCE
SKILLS
TRAININGS
Rescue training, CPR etc. from Rescue team1122.
Different Firefighting Sessions and Emergency Handling from EFSL safety department & from Rescue Team. Control awareness Sessions on behavior base.
Dozen sessions on Work permits, Safety procedures and team work. Training of HSE. PLC/DCS trainings.