Customvac · 2019. 1. 10. · Created Date: 5/29/2015 6:07:49 AM

2
First Choice with Contractors Involved in TDG CV Line of Top Quality Vacuum Equipment Custom Built With Direct Customer Input Hydrovac Unit 822 TC 407/412 CSA B620-09

Transcript of Customvac · 2019. 1. 10. · Created Date: 5/29/2015 6:07:49 AM

Page 1: Customvac · 2019. 1. 10. · Created Date: 5/29/2015 6:07:49 AM

First Choice with Contractors Involved in TDG

CV Line of Top QualityVacuum Equipment

Custom Built With Direct Customer Input

Hydrovac Unit822 TC 407/412 CSA B620-09

Page 2: Customvac · 2019. 1. 10. · Created Date: 5/29/2015 6:07:49 AM

CV Lineof Top Quality

Vacuum Equipment

Custom Built Vacuum EquipmentOnline at custOmvac.cOm

DesiGn: Vessel designed and constructed in full compliance with Transport Canada TC 407/412 and CSA B620-09

Debris compartment:Tank diameter 78” (12’ seam to seam) •78” x 5/16” F & D heads•78” x 5/16” shells•Formed angle front & rear pedestals•Three 4” roll bars•Three external reinforcement rings•Reinforcing pads for all tank attachments•Tank Lock Down Assembly to meet current •B620 Code8” Primary shut-off assembly with 8” flanged outlet•8” isolation valve @ shut-off air actuated•Recessed liquid level indicator D/S•Full opening rear door c/w six pinwheel door locks •6”Brass Suction valve c/w 6” sandpipe, alumi-•num camlock/cap D/S4”Brass Suction valve c/w aluminum camlock •and cap P/S12” Hydraulic flange mounted mudgate with •sliding lock mechanism and 4” Brass valve with aluminum camlock and capAll rear valves heated, and equipped with air/•open- spring/close air actuators & control switchesOperating Temperature -20 deg F to 200 deg F•Vessel hydrotested to 40 PSI•

Blower specifications & allied equipment:Hibon SIAV 822•2650 CFM free air rating•27” Hg Maximum Vacuum@ sea level•8’ Four-Way Diverter valve ( Vacuum to Pres-•sure Mode )8” Double door check valve ( to prevent blower •back spin )Prestage filter assembly c/w 16” filter•One intake silencer, One exhaust silencer•8” cyclone with bottom cleanout door & 2” •heated drain valve

Hydraulic system (linde–closed loop design):8 Bolt PTO for blower•6 Bolt PTO for wash•Hydraulic pump and motor for blower•Hydraulic pump and motor for Triplex pump•

Tandem gear pump for Auxiliary functions•High torque/temp drive coupler with flex insert•Spool type valve control bank for pump and •allied functionsRear control section for door and Dumpgate on •deck D/SJoystick speed control for blower•Torque control for vac pressure •90 gallon oil tank c/w vent, site glass, filters, •temperature gauge, and inspection hatchTwo 12 volt oil coolers•3 stage hydraulic hoist cylinder•

Boom:8” x 270 deg telescopic suction boom•12” knife gate gate valve assembly with shear •sectionAccumulator for knife gate code compliance•8” boom hose with end•One wireless remote controller•One hard wired pendant controller for backup•

Plumbing:8” piping c/w 8” oil & gas loop hose•

Wash system:Cat 3560 Triplex plunger pump rated 20 US-•GPM @ 4000 psi2” Bronze strainer,1” high pressure Baird relief •valve,Three Hydraulic Rewind Reels•100’ x 1/2” pressure hose•100’ x 3/8” temperature rated Steam hose•100’ x 3/8” degreaser hose•

note: Wash Systems Are Winterized for cold weather operation

Wash accessories:One wash gun, wand, nozzle and quick coupler•One steam wand, nozzle and quick coupler•One 6’ Hydro Dig Wand c/w 4’ extension and •Turbo NozzleOne degreaser tank assembly c/w tank, stand, •pump, gun, wand, and nozzle

Hot Water system:Hotshot 980,000 BTU/hr heater c/w relief •valves temperature gauge; Honeywell control ,Diagnostic panel

2000 Watt Pure Sign Inverter•Wet Steam kit plumbed with high pressure ball valves•Safety Feature: a 340 deg. Auto Shut-Off on •Heater SystemNew style 18 GPM solid brass Flow Switch with •no bypass lineAll plumbing stainless steel•

Wash cabinet:Milron Aluminum Crossover cabinet c/w Large •doors D/S , P/SSmall access door in large door P/S for hose •accessHeaters, LED Lights, and Auto Vent•

Water compartment (4 cubes-880 imp Gal):20” top mounted Manway•Stainless steel liquid level indicator assembly P/S•2” heated fill, breather and suction•2” heated drain valve air actuated, Switch •control at operator station2” heated hard pipe supply direct connection •through cabinet to triplex2” heated Vac/water changeover valve air •actuated

vibrator:

Global hydraulic vibrator assembly mounted •on bottom of tank with reinforcement pads, heavy duty mounting channel and pressure relief valve.

Pressure Relief:One 3” x 30 PSIG pressure relief vent•One 2” PRV in lower suction pipe•2” vacuum breakers installed on exhaust silencer•

Gauges:Gauge assembly with tank vacuum/pressure •gauge, hydraulic pressure gauges. Blower temperature gauge remote mounted •on D/S.

Frame, Deck and Bumper:Full length subframe c/w 1/8” checker plate •hose tray/fender assemblyc/w heavy duty outrigger supports,1-1/4” tube •handrails, close in plate.Code rear bumper with light boxes and rear •

tire skirtSubframe supports decking, rear hoist hinges & •front hoist cradle

cabinets:

One steel 72” three door deck box•Two rear skirt fitting boxes•

electrical system:Waterproof main circuit control box self con-•tained power supplySealed wire harness c/w waterproof junction •boxesL.E.D. lamps (Clearance, park, signal)•Sealed L.E.D. reverse lamps•Four L.E.D. style work lights•L.E.D. WORK LIGHTS on the Boom Frame•Electrical system shut-down at key•Sealed rear skirt lamp modules•Stop and turn L.E.D sealed lamp modules on •top ring of door.Back up alarm•Truck cab and deck mount blower switches•

additional equipment:Catwalk & ladder on upper suction pipe driver’s •side.PTO Hour meter installed in truck cab•Chain hanger, slide out style•Mudflaps•50’ground cable (wind up style)•Ground studs mounted off rear peds D/S & P/S•30# fire extinguisher/Brkt/Cover•Boom hose holders P/S•Two 6” x 5’ aluminum dig tubes with Band •Clamp ends one with rubber tipOne 8” x 6” x 4’ aluminum adapter•

Paint:The entire tank and body of vacuum system •shall be sandblasted, primed and painted with Endura paintWater Tank Lined With Devoe 233 •

Other items:Operators manual issued with completed unit•Unit includes (NSM) National Safety Mark•One year Manufacturer Ltd warranty•

HYDROVAC 822 TC 407/412 and CSA B620-09

installation:Complete system installed on Customer Supplied Tri-Drive chassis. Any relocation of truck parts or frame alterations will be charge for with cost added to final price

NOTE: TRUCK CHASSIS SUPPLIED WITH LONG SLEEPERS AND REAR BUMPERS MAY REDUCE VACUUM TANK LENGTH / VOLUME IN ORDER MEET LEGAL BUMPER TO BUMPER OVERALL LENGTH OF 41 FEET

Custom Vac Services Ltd reserves the right to engineer and manufacture it’s products in accordance with it’s warranty and design policies. For more information please contact

custom vac services ltd. 904 29 ave nisku, aB. t9e 1B7tel: (780) 955-9344 Fax: (780) 955-9343