1 | VARİAN ONCOLOGY SYSTEMS
VARIANONCOLOGYSYSTEMS
TrueBeam™Machine Performance Check - Automatic Quality Assurance Tools TrueBeamTM 2.0 ImprovementsRapidPlanTM
Luis Carvalho
Product ManagerDelivery Systems
Nov 21, 2013Antalya
2 | VARİAN ONCOLOGY SYSTEMS
Disclaimer
• Employed by Varian Medical Systems
3 | VARİAN ONCOLOGY SYSTEMS
4 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™ - Radically Different
5 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™ - Radically Different
Field Size: 40*40 cm2
Center leafs (20 cm): 5 mmOuter leafs: 10 mm
Field Size: 40*22 cm2
Center leafs (8 cm): 2.5 mmOuter leafs: 5 mm
TrueBeam™ TrueBeam™ STx
6 | VARİAN ONCOLOGY SYSTEMS
TrueBeam - Worldwide Clinical Operation
ClinicalUse
>600 installations >850 orders
Registrations / Clearances: US FDA, CE Mark/ MDD, Russia Gost, Saudi Arabia SFDA, China SFDA, Japan Shonin, Australia & New Zealand, Thailand, Korea, India, …
7 | VARİAN ONCOLOGY SYSTEMS
CustomerFavorites
Ease of UseConfidence for SRS/SBRTand Gating• Accuracy• ImagingSpeed• Reduction in Tx time in SBRT
cases by 2.5 to 3X• High Intensity Mode• Automation
TrueBeam in Clinical Use
10 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Heart of TrueBeam—The Maestro™ Control System
11 | VARİAN ONCOLOGY SYSTEMS
Accelerator/Accelerator Solenoid
Bend Magnet
Carousel
Collimator & MLC
Shielding
Energy Switch
Target
Stand / Gantry
12 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
High Intensity - Flattening Filter Free (FFF) Mode
Higher dose rates, lower scatter and out of field leakage are possible by removing the flattening filter
Gains for IMRT, RapidArcor small field SRS
Available in clinical mode for 6 MV 1400 MU/min10 MV 2400 MU/min
13 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Treatment Console
14 | VARİAN ONCOLOGY SYSTEMS
Console Pendant Couch
Common User Interface
15 | VARİAN ONCOLOGY SYSTEMS
Safety
• Touch guards• Capacitive collision detection• Machine motion model• Zone rules• Live view• Standardized user interface• Pre-treatment dry-run• LaserGuard II
TrueBeam Highlights
16 | VARİAN ONCOLOGY SYSTEMS
ISOCal Goal – Align ISOcenters
Source: University Hospital Zürich, Hrbacek, Lang
17 | VARİAN ONCOLOGY SYSTEMS
ISOCal Phantom
• Aligning kV imaging ISOC toMV treatment ISOC
18 | VARİAN ONCOLOGY SYSTEMS
ISOCal Results
Source: University Hospital Zürich, Hrbacek, Lang
21 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Innovative Treatment Techniques
GatedRapidArc
• Next evolutionary step• Compensates for tumor
motion• Expands application of
RapidArc treatments tomoving tumors
• Enables faster treatmentsof tumors that move with respiration
24 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Intelligent
SmartConnect
25 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Intelligent
RemoteMachineDiagnosis
• Service can proactively and remotely analyze machine status
• Quick access to experts• Faster diagnosis and resolution
27 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Innovative
DeveloperMode
• New method of collaboration• Partnership for developing new
innovations• Protected non-clinical
environment
29 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Exotic Trajectories
Red Journal - paper from MSKCC New York in Press
Dynamic trajectory-based algorithm integrates optimized couch and collimator trajectories into RapidArc/VMAT
30 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™
Exotic Trajectories
39 | VARİAN ONCOLOGY SYSTEMS
TrueBeam 2.0
40 | VARİAN ONCOLOGY SYSTEMS
EnhancedIGRT
• New 2D / 3D algorithm(6DoF)
• Ad-hoc imaging(DRR on the fly)
• Additional triggers forintra-fraction imaging
• 4D CBCT
• CBCT Stitching
Selected features
64 | VARİAN ONCOLOGY SYSTEMS
On-Demand Imaging
• Deploy kV imaging system any time during treatment
• Instant DRR creation
• Match and Shift
TrueBeam 2.0 – New Features
67 | VARİAN ONCOLOGY SYSTEMS
Several mechanisms to trigger kV image acquisition:
Time“every 10 seconds”
Gantry angle “every 10 degrees”
Monitor Units“every 50 MU”
200 201
Respiration“every breath”
Triggered Image acquisition
68 | VARİAN ONCOLOGY SYSTEMS
Triggered Imaging
• Project onto real-time triggered kV
• Outline of 3D structures from treatment planning
• Circular outline when treating with markers
Advanced IGRT and Motion Package
69 | VARİAN ONCOLOGY SYSTEMS
Advanced IGRT and Motion Package
70 | VARİAN ONCOLOGY SYSTEMS
New “Vivid” Display filter
CE Mark & Intl. Registrations Pending – Not for Sale in all Markets
71 | VARİAN ONCOLOGY SYSTEMS
43x43cm MV Detector
active area30X40cm2
active area43X43cm2
74 | VARİAN ONCOLOGY SYSTEMS
4D CBCT
Basic 4D Advanced 4D
Images courtesy of Free University of Amsterdam, W. Verbakel
75 | VARİAN ONCOLOGY SYSTEMS
Advanced IGRT & Motion PackageAdvanced Reconstructor - Multiscan CBCT
77 | VARİAN ONCOLOGY SYSTEMS
PerfectPitch™ Couch
78 | VARİAN ONCOLOGY SYSTEMS
PerfectPitch™ Couch
• Increased treatment precision for challenging indications• Robotic beam alignment with 6 degrees of freedom • Smooth Isocentric rotation
79 | VARİAN ONCOLOGY SYSTEMS
• Increased treatment precision for challenging indications• Robotic beam alignment with 6 degrees of freedom • Smooth Isocentric rotation
• Fully integrated• Sub-millimeter Accuracy• Robust Design – supports up to 200 kg
PerfectPitch™ Couch
90 | VARİAN ONCOLOGY SYSTEMS
Upcoming Options
TrackingCouch / MLC
• Non-Clinical(Developer mode)
• Couch or MLC compensation
• Periodic with model
• Non-periodic with Calypso(Real-Time Feedback)
92 | VARİAN ONCOLOGY SYSTEMS
TrueBeam™ 2.0Dynamic Couch Tracking - Reactive
93 | VARİAN ONCOLOGY SYSTEMS
Machine Performance Check
94 | VARİAN ONCOLOGY SYSTEMS
What is MPC?
An application to verify that geometry and beam performance of the TrueBeamTM
accelerator are operating within system specifications.
Automated checks which can be performed on a daily basis using kV and MV imaging systems as the primary measurement devices.
95 | VARİAN ONCOLOGY SYSTEMS
What is MPC?
IsoCal Phantom + Holder
kV / MV imaging systems
+MPC application running on treatment console
+
96 | VARİAN ONCOLOGY SYSTEMS
Beam Constancy Check(against reference MV image)
Beam output change
Beam uniformity change
Beam center shift
What does MPC test?Geometry Check Size of treatment isocenter
Coincidence of treatment and imaging isocenter
Positioning accuracy of MV and kV imaging systems
Accuracy of collimator and gantry rotation angle
Positioning accuracy of jaws and MLC leafs
Couch positioning accuracy (up to 6 DoF)
97 | VARİAN ONCOLOGY SYSTEMS
MPC Workflow
98 | VARİAN ONCOLOGY SYSTEMS
MPC Review Workspace
Available on treatment console and on separate workstation (MPC in offline mode)
Detailed analysis of recent and previous MPC results (including acquired images)
Simple trend analysis
Generation of test reports
Export of test results to CSV files
99 | VARİAN ONCOLOGY SYSTEMS
100 | VARİAN ONCOLOGY SYSTEMS
101 | VARİAN ONCOLOGY SYSTEMS
102 | VARİAN ONCOLOGY SYSTEMS
Future Steps
Automation of Quality Assurance Procedures Interface for automated QA scripting
Automated shoot & measure sequences
Enabling customized analysis using e.g. Matlab based on exported MPC data
103 | VARİAN ONCOLOGY SYSTEMS
RapidPlan™
104 | VARİAN ONCOLOGY SYSTEMS
Clinical Process
Contouring Treatment Planning
Plan Approval
Physics & QA
Treatment Delivery
• Each step in the treatment process has variability & inefficiencies associated with it
SmartSeg ? ? QA tools (MPC)
Delivery accuracy
(RapidArc)
• Varian provides technology to reduce variability at each step of the process
CE Mark & Intl. Registrations Pending – Not for Sale in all Markets
105 | VARİAN ONCOLOGY SYSTEMS
Reference case match
Auto contour
Auto planAuto Evaluation
Add to Knowledge
Base
New patient
Contours morphed from Expert Case
Local Knowledge Base
Evaluate against prior experience
IMRT Dose distribution derived from prior
experience
TargetCord
Parotid
Patient Case
Reference CaseShare cases with colleagues.
Improve quality of care globally.
Introducing RapidPlan™
107 | VARİAN ONCOLOGY SYSTEMS
Knowledge-Based Planning
-0,2
0
0,2
0,4
0,6
0,8
1
0 10 20 30 40 50 60
Measurements
Dev
iatio
n fro
m M
ean Implementation of a
knowledge based approach
CE Mark & Intl. Registrations Pending – Not for Sale in all Markets
Source: Washington University
108 | VARİAN ONCOLOGY SYSTEMS
Knowledge-Based Planning
New IMRT users
• Increase quality• Provide good
starting point• Confidence
Experienced IMRT users
• Reduce variability
• Normalize clinician skills & experience
Busy clinics
• Increase efficiency
Clinical trials
• Easier to participate
• Greater consistency
CE Mark & Intl. Registrations Pending – Not for Sale in all Markets
109 | VARİAN ONCOLOGY SYSTEMS
Knowledge-Based Planning
What RapidArc™ did for Treatment Delivery;
KBP will do for Treatment Planning
Start with your best plan
Quality Consistency Efficiency
CE Mark & Intl. Registrations Pending – Not for Sale in all Markets
110 | VARİAN ONCOLOGY SYSTEMS
Knowledge-Based Planning
CE Mark & Intl. Registrations Pending – Not for Sale in all Markets
111 | VARİAN ONCOLOGY SYSTEMS