Cse & WTe 350 - Aermec
Transcript of Cse & WTe 350 - Aermec
Cse & WTe 350FlaT bed uniT1 or 2 roW oF Fans
air cooLed condensed Unit | drY cooLer Unit
AIR CONDENSER AND lIquID COOlERSwITH AxIAl fANS• Configuration: 1 exchangers• 1 or 2 circuits• 1 or 2 fans row• Wide range of capacity• 60 models available as condenser• 60 models available as dry coolers• Fan diameter: 350 mm• Number of fans: from 1 to 6• Vertical or horizontal installation
CONSTRuCTION CHARACTERISTICSThey are realized with technologies and material which guarantee strength against atmospheric agents.High efficiency finned block heat exchangers realized with copper tubes and alluminium fins. New generation axial fans with 350 mm diameter both available version AC and EC chosen for minimizing the energy consumption. Standard unit are supplied with cabled fans and electrical box with clamps.
AVAIlAblE fANSBM°: 4-poles 1-phaseSM°: 6-poles 1-phaseCMB: fan motor 1-phase EC high power CMS: fan motor 1-phase EC low noise level
ACCESSORIESCSE and WTE unit could be equipped with main switch, switchboard, cut phase fan speed regulator or EC controller and temperature sensor, pressure sensor or 0-10V signal.Anti-vibration device are also available for reducing machine’s vibrations.
Models
Model
Main switch
Switchboard
Phase cut regulatori
Controller ec
Probe Piedini
Anti-vibration
device
CSE-WTE BM° p p p p p
CSE-WTE SM° p p p p p
CSE-WTE CMB p p p p p p
CSE-WTE CMS p p p p p p
Cse condenser and WTe dry cooler’s serie meet equipment’s power requirements.They are available from 1 up to 6 fans both version aC and eC.
CApACITYIn air condenser unit power range with refrigerant R134a is from 1.1 up to 17.5 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)
In air condenseer unit power range with refrigerant R410A is from 1.4 up to 20.4 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)
In dry cooler unit power range with ethylene glycol 30% is from 1.1 up to 16.1 tons (ambient air temperature +77°F, inlet liquid temperature +104°F outlet liquid temperature +95°F according to EN 1048)
TeChniCal draWinG
Quota a
- CSE/WTE° 301(3/4)
- CSE/WTE° 302(3/4)
- CSE/WTE° 303(3/4)
- CSE/WTE° 304(3/4)
- CSE/WTE° 306(3/4)
Quota a
12.1
3 in
22
mm
22.0
5 in
43.7
1 in
0 10 20 30 40 50 60 70
CMS
CMB
SM°
BM°
kW (T.air 25°C - T.cond 40°C)
CSE 350 R134a
0 10 20 30 40 50 60 70 80
CMS
CMB
SM°
BM°
kW (T.air 25°C - T.cond 40°C)
CSE 350 R410A
0 10 20 30 40 50 60
CMS
CMB
SM°
BM°
kW (T.air 25°C - T.liq 40/35°C)
WTE 350
24.01 in (single row of fans)
45.67 (single row of fans)
67.32 (single row of fans)
45.67 (double row of fans)
67.32 (double row of fans)
AERMECAddress: 1608 Bonhill Road. Mississauga, Ontario, CA L5T 1C7Website: www.aermec.usEmail: [email protected]: 1-800-567-2221US: 1-888-567-2227