CRYOCOOLER MEMBRANE TECHNOLOGY - Fabrum Solutions

1
Reliquefaction Module Cryocooler LN2 Tank capacity Input Power Weight Dimensions (m) L x W x H Liquefaction rate (from N2 @ 300 K) LGU 350 PTC1000-1 500 liters 27 kW 2100 kg 3.5 x 1.8 x 3.0 15 liters/hour LGU 700 PTC1000-2 1000 liters 55 kW 4000 kg 4.0 x 2.5 x 3.0 30 liters/hour LGU 1000 PTC1000-3 1500 liters 85 kW 6000 kg 4.5 x 3.0 x 3.0 45 liters/hour Crycooler Power @ 77 K No Load Temperature Input Power Weight Dimensions (m) L x W x H PTC90 120 W 40 K 3.1 kW 120 kg 0.7 x 0.4 x 0.6 Power @ 110 K 180 W PTC330 480 W 45 K 12 kW 800 kg 1.9 x 0.8 x 1.7 860 W PTC1000 1450 W 43 K 25 kW 1300 kg 1.8 x 1.2 x 2.2 2500 W STC1500 > 3000 W 40 K 40 kW 2100 kg 2.0 x 1.6 x 1.5 > 7000 W AFCryo is a joint venture established in 2017 between Absolut System and Fabrum Solutions A RANGE OF LIQUEFACTION CAPABILITY OFF-THE-SHELF FROM: 20 LITERS/DAY up to 1000 LITERS/DAY A RANGE OF COOLING POWER OFF-THE-SHELF FROM: 100W@80K up to 3000W@80K *from NZ @ 300K, 1bar CRYOCOOLER MEMBRANE TECHNOLOGY MORE THAN 10KW @ 110K UNDER DEVELOPMENT PTC330 PTC1000 STC1500

Transcript of CRYOCOOLER MEMBRANE TECHNOLOGY - Fabrum Solutions

Page 1: CRYOCOOLER MEMBRANE TECHNOLOGY - Fabrum Solutions

Reliquefaction Module

Cryocooler

LN2 Tank capacity

Input Power

Weight

Dimensions (m) L x W x H

Liquefaction rate(from N2 @ 300 K)

LGU 350

PTC1000-1

500 liters

27 kW

2100 kg

3.5 x 1.8 x 3.0

15 liters/hour

LGU 700

PTC1000-2

1000 liters

55 kW

4000 kg

4.0 x 2.5 x 3.0

30 liters/hour

LGU 1000

PTC1000-3

1500 liters

85 kW

6000 kg

4.5 x 3.0 x 3.0

45 liters/hour

Crycooler

Power @ 77 K

No Load Temperature

Input Power

Weight

Dimensions (m) L x W x H

PTC90

120 W

40 K

3.1 kW

120 kg

0.7 x 0.4 x 0.6

Power @ 110 K 180 W

PTC330

480 W

45 K

12 kW

800 kg

1.9 x 0.8 x 1.7

860 W

PTC1000

1450 W

43 K

25 kW

1300 kg

1.8 x 1.2 x 2.2

2500 W

STC1500

> 3000 W

40 K

40 kW

2100 kg

2.0 x 1.6 x 1.5

> 7000 W

AFCryo is a joint venture established in 2017 betweenAbsolut System and Fabrum Solutions

A RANGE OF LIQUEFACTION CAPABILITY OFF-THE-SHELF FROM:20 LITERS/DAY up to 1000 LITERS/DAY

A RANGE OF COOLING POWER OFF-THE-SHELF FROM:100W@80K up to 3000W@80K

*from NZ @ 300K, 1bar

CRYOCOOLER MEMBRANE TECHNOLOGY

MORE THAN10KW @ 110K

UNDERDEVELOPMENTP

TC

330

PT

C10

00

STC

150