Cryo-Tracker Level Temperature and Mass Gauging Fluid Sensors

download Cryo-Tracker Level Temperature and Mass Gauging Fluid Sensors

of 15

description

cryogenic grinding seminar presentation

Transcript of Cryo-Tracker Level Temperature and Mass Gauging Fluid Sensors

  • Cryo-Tracker Level, Temperature,and Mass Gauging Fluid Sensors

  • Behavior of Sub-cooled Propellants in Room Temp.Fig: Liquid Nitrogen unloaded from a small a Dewar Flask to a bucket in a laboratory.

  • Dewar FlaskFig: A 25 l liquid nitrogen laboratory Dewar flask.Inner wall linings are silvered to reduce heat leakage.

  • Flexible Sensing Probe Probe is made of series of polyimide layers of thickness 0.0254 mm.Rakes made of stainless steel tubing, wire, and phenolic insulators weigh (6.70 g/cm).

  • Internal Structure of Cryo-Tracker Silicon diode sensors incorporated with the probe.Conductor Traces which constitute the rake of the temp- element

  • Installed Cryo-Tracker Probe Cryo-Tracker probe 60 ft. long. 2.5 cm wide. containing 26 silicon diode sensors.Its weight is less than 0.59 kg.

  • Stratification of Sub-cooled Propellants The heat leak causes the propellant to warm and stratify due to natural buoyancy forces.

  • Cryo-Tracker Initially designed for incorporating in the propellant vessels of reusable launch vehicles.

  • Purpose of Cryo-TrackerFor knowing the amount of propellant loaded in.For knowing the liquid & ullage temperature.For knowing liquid level.

  • Mass Gauging MethodThe entire liquid and ullage temperature profile is first obtained.Tank pressure can then be used to calculate a liquid density profile. Liquid density profile is integrated over the known tank volume.

  • Dual-Purpose Probe. Temperature measured using silicon diode sensors. Liquid level detection accuracy is a function of the sensor spacing. For 12 inch sensor spacing, the overall liquid level accuracy is 6 inches.

  • PerformanceConsistent thermal response can be seen between the sensing elements in a dual-element probe when its thermal-cycled in liquid nitrogen.

  • Hot-Fire Test (anomaly condition) The probe is also capable of measuring transient fluid temperature changes.Figure : Tracking the rapid change in liquid oxygen temperature when warm gases injected into the tank mixed the contents.

  • Advantages of Cryo-TrackerOperating CostsAccuracyReliabilitySafetyEfficiencyScalabilityFlexibility

  • Commercial ApplicationsCryogenic storage and transport tanksHome oxygen vessels Medevac helicopter and military field hospital oxygen-generating systemsAutomobiles running on liquid hydrogen or liqufied natural gas