Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

32
1 ® The information presented in this booklet is intended to reflect the most common diagrams utilised by installers when commissioning a ST Runner system. For assistance with wiring diagrams and programming your ST Runner system, please contact your local agent or Housewatch direct on :- Phone; 1300 472 472 Fax; 1300 672 672 ST RUNNER 4 TO 8 ALARM DIAGRAM AND INSTALLATION MANUAL Version 1.2

Transcript of Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

Page 1: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

1

®

The information presented in this booklet is intended to reflect the most common diagrams

utilised by installers when commissioning a ST Runner system.

For assistance with wiring diagrams and programming your ST Runner system, please contact

your local agent or Housewatch direct on :-

Phone; 1300 472 472

Fax; 1300 672 672

ST RUNNER 4 TO 8 ALARM

DIAGRAM AND INSTALLATION MANUAL

Version 1.2

Page 2: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

2

NOTE

NOTE if NOT using a sensor (PIR) in the

System, a 2.2k RESISTOR MUST be used across

the zones

If not using the 2.2k resistor in the system you

MUST change the programming All wiring diagrams are all with

a 2.2k resistor in them

Page 3: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

3

INDEX

1. Wiring PIR’s ...................................................................... 4-9

2. Double Zone Wiring Diagram.......................................... 10,11

3. Installing Single Channel Receiver.................................. 12

4. Installing Four Channel Receiver.................................... 13

5. Setting Away and Stay modes with 4 Channel Receiver 14

6. Setting Areas A & B with 4 Channel Receiver .............. 15

7. Installing a Smoke Detector ............................................. 16,17

8. Wired Panic Alarm ...........................................................18

9. Installing Panic Alarm ......................................................18

10. Add, Change, Delete User Numbers................................ 19

11. Installing a Smoke Detector .............................................19

12. Setting Zones to Stay Mode .............................................. 20

13. Chime Zones Settings........................................................ 20

14. Entry & Exit Delay Times ................................................ 20

15. Mobile Phone Setup........................................................... 21,28

16. Dialler Reporting Options ................................................ 21,28

17. Monitoring Station Setup.................................................. 28,31

18. Crow Wave 8 Basic Setup Diagram................................. 32

Page 4: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

4

SENSOR WIRING FOR 2 ZONES

INSTALLING 2 ZONES WITH 2.2K RESISTORS

Zone 1

SENSOR WIRING FOR 1 ZONE

INSTALLING 1 ZONE WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

2.2K RESISTORS A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

Zone 2

Page 5: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

5

SENSOR WIRING FOR 4 ZONES

INSTALLING 4 ZONES WITH 2.2K RESISTORS

SENSOR WIRING FOR 3 ZONES

INSTALLING 3 ZONES WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 2

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 3

2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 2

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 3

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 4

Page 6: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

6

SENSOR WIRING FOR 5 ZONES

INSTALLING 5 ZONES WITH 2.2K RESISTORS

Zone 5

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 3

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 4

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

4.7k

8.2k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 2

PROGRAMMING ZONE 5 INTO SYSTEM

• Press Program button then installers number (000000) then Enter.

You are now in programming mode. The program light will be flashing.

• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 5 on)

• Press Program then 125 then enter. Then press 1 then Enter. 3 will flash, press 14 then 14

will flash back then Enter (this changes the resistors).

Page 7: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

7

SENSOR WIRING FOR 6 ZONES

INSTALLING 6 ZONES WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 2

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 3

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 4

4.7k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 5

8.2k

Zone 6

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

8.2k

4.7k

PROGRAMMING ZONE 5 & 6 INTO SYSTEM

• Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 5 on).

• Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 6 on).

• Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

• Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

Page 8: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

8

SENSOR WIRING FOR 7 ZONES

INSTALLING 7 ZONES WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 2

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 3

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 4

4.7k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 5

8.2k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 6

8.2k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 7

8.2k

4.7k 4.7k

PROGRAMMING ZONES 5, 6 & 7 INTO SYSTEM • Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 5 on).

• Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 6 on).

• Press Program then 122 then enter. Then press 7 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 7 on).

• Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

• Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

• Press Program then 125 then enter. Then press 3 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

Page 9: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

9

SENSOR WIRING FOR 8 ZONES

INSTALLING 8 ZONES WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 2

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 3

2.2K RESISTORS

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 4

4.7k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 5

8.2k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 6

8.2k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 7

8.2k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 8

8.2k

4.7k 4.7k

4.7k

PROGRAMMING ZONES 5, 6, 7 & 8 INTO SYSTEM • Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 122 then enter. Then press 5 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 5 on).

• Press Program then 122 then enter. Then press 6 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 6 on).

• Press Program then 122 then enter. Then press 7 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 7 on).

• Press Program then 122 then enter. Then press 8 then Enter. 7 will be lit up then press 1

then Enter (this turns zone 8 on).

• Press Program then 125 then enter. Then press 1 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

• Press Program then 125 then enter. Then press 2 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

• Press Program then 125 then enter. Then press 3 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

• Press Program then 125 then enter. Then press 4 then Enter. 3 will be lit up then press 14

then 14 will flash back then Enter (this changes the resistors).

Page 10: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

10

Blue Wire

Blue Wire White Wire

White Wire

Join Wires

Inside panel

White Wire

Blue Wire Blue Wire White Wire

DOUBLE ZONE WIRING DIAGRAM

JOIN BLUE AND WHITE WIRE INSIDE THE PANEL

INSTALLING ZONES WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 1

4.7k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

Zone 5

8.2k 2.2k

Page 11: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

11

DOUBLE ZONE WIRING DIAGRAM

JOIN BLUE AND WHITE WIRE INSIDE THE PANEL

DIFFERENT SENSOR WIRING AND REED SWITCH WIRING

INSTALLING ZONES WITH 2.2K RESISTORS

tam

per

12 V

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

GN

D

GN

D

12 V

2

1

Zone 1

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

4.7k

Zone 5

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

8.2k 2.2k

12 V

TA

MP

TA

MP

0 V

N/O

CO

M

Zone 1

4.7k

12 V

TA

MP

TA

MP

0 V

N/O

CO

M

Zone 1

4.7k

12 V

TA

MP

TA

MP

0 V

N/O

CO

M

Zone 5

8.2k 2.2k

12 V

TA

MP

TA

MP

0 V

N/O

CO

M

Zone 5

8.2k 2.2k

12 V

TA

MP

TA

MP

0 V

ALA

RM

Zone 5

8.2k

ALA

RM

12 V

TA

MP

TA

MP

0 V

ALA

RM

Zone 1

4.7k

ALA

RM

Zone 5

COM N/C N/O

COM N/C N/O

Zone 1

REED SWITCH WIRING

COM N/C N/O

Zone 1

4.7k

8.2k

2.2k

4.7k

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

8.2k

2.2k

Zone 5

12 VOLT SUPPLY

FROM BOARD

Page 12: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

12

ADDING A TRANSMITTER (75-063) & SINGLE CHANNEL RECEIVER (75-067)

Enter into programming mode

Installer’s code (000000) set by default

• Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 111 then Enter. Then press 1 then Enter.

Press 1 so it lights up. Then Enter.

SETTING STROBE TO FLASH

(This will set the strobe to flash when the alarm is armed / disarmed)

• Press Program then 54 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press Program then 56 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press program then 39 then Enter. Then 2 then Enter. Then time in seconds

(ie 20 = 2 seconds) then Enter.

• Exit Program mode. Press Program then Enter.

SETTINGS FOR SINGLE CHANNEL RECEIVER 75-067

Set for one second

Cut LP 2

Don’t cut LP 1

4.7k resistor

75-067 Single

Channel Receiver

com

N/C

N/O

+ -

tam

per

12 V

Crow Alarm Panel

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

POS

NEG

CLK

DAT

LIN

GN

D

IN

AC

EARTH

GN

D

12 V

2

1

Alarm panel

Tamper switch

Normally closed

2.2k resistor

Already

In system

Page 13: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

13

ADDING A TRANSMITTER (75-063) & 4 CHANNEL RECEIVER (75-064)

Enter into programming mode

Installer’s code (000000) set by default

• Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 111 then Enter. Then press 1 then Enter.

Press 1 so it lights up. Then Enter.

SETTING STROBE TO FLASH

• Press Program then 54 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press Program then 56 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press program then 39 then Enter. Then 2 then Enter. then time in seconds

(ie 20 = 2 seconds) then Enter.

• Exit Program mode. Press Program then Enter.

4.7k resistor

75-064

4 CHANNEL

RECEIVER

CH 1 CH 2 CH 3 CH 4 12v

Pwr In

CO

M

CO

M

CO

M

CO

M

N/C

N/C

N/C

N/C

N/O

N/O

N/O

N/O

+ –

tam

per

12 V

Crow Alarm Panel

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

POS

NEG

CLK

DAT

LIN

GN

D

IN

AC

EARTH

GN

D

12 V

2

1

Alarm panel

Tamper switch

Normally closed

2.2k resistor

Already

In system

Page 14: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

14

2.2k resistor

Already

In system

AWAY (ARM / DISARM) AND STAY MODE

USING TRANSMITTER & 4 CHANNEL RECEIVER (75-064)

Enter into programming mode

Installer’s code (000000) set by default

• Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 111 then Enter. Then press 1 then Enter.

Press 1 so it lights up. Then Enter.

• Press Program then 111 then Enter. Then press 2 then Enter.

Press 1 so it lights up. Then Enter.

• Press Program then 112 then Enter. Then press 2 then Enter.

Press 1,3 so the lights go off and then press 2,4 so they light up. Then Enter.

SETTING STROBE TO FLASH

• Press Program then 54 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press Program then 56 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press program then 39 then Enter. Then 2 then Enter. then time in sec then Enter

• Exit Program mode. Press Program then Enter.

4.7k resistor

75-064

4 CHANNEL

RECEIVER

CH 1 CH 2 CH 3 CH 4 12v

Pwr In

CO

M

CO

M

CO

M

CO

M

N/C

N/C

N/C

N/C

N/O

N/O

N/O

N/O

+ –

tam

per

12 V

Crow Alarm Panel

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

POS

NEG

CLK

DAT

LIN

GN

D

IN

AC

EARTH

GN

D

12 V

2

1

Alarm panel

Tamper switch

Normally closed

8.2k resistor

Page 15: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

15

AREAS A and B

USING TRANSMITTER & 4 CHANNEL RECEIVER (75-064)

Enter into programming mode

Installer’s code (000000) set by default

• Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 111 then Enter. Then press 1 then Enter.

Press 1 so it lights up. Then Enter.

• Press Program then 111 then Enter. Then press 2 then Enter.

Press 2 so it lights up. Then Enter.

.

SETTING STROBE TO FLASH

• Press Program then 54 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press Program then 56 then Enter. Then press 1 then Enter.

Press 2 so it lights up. Then Enter.

• Press program then 39 then Enter. Then 2 then Enter. then time in sec then Enter

• Exit Program mode. Press Program then Enter.

4.7k resistor

75-064

4 CHANNEL

RECEIVER

CH 1 CH 2 CH 3 CH 4 12v

Pwr In

CO

M

CO

M

CO

M

CO

M

N/C

N/C

N/C

N/C

N/O

N/O

N/O

N/O

+ –

tam

per

12 V

Crow Alarm Panel

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

POS

NEG

CLK

DAT

LIN

GN

D

IN

AC

EARTH

GN

D

12 V

2

1

Alarm panel

Tamper switch

Normally closed

8.2k resistor

2.2k resistor

Already

In system

Page 16: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

16

ADDING SMOKE DETECTOR TO ZONE

Enter into programming mode

Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 122 then Enter.

Select the zone you wish to use, As Normally open. Then Enter.

• 1,6,7 will be lit up. press 6,7,2 No 2 will light up and 6,7 will go out. Then Enter.

• Press Program then 123 then Enter.

Select the same number zone as above. (The zone you made normally open )

Then Enter. Press number 5 then enter.

This will set zone as fire zone.

• Exit Program mode. Press Program then Enter.

2.2k resistor tam

per

Crow Alarm Panel

12 V

O V

Set up for zone 2 When Zones 5 to 8 not used

2.2k resistor

12 V

O V

Set up for zone 4 When Zones 5 to 8 not used

Latching smoke detector

Normally open

Latching smoke detector

Normally open

Address Program 122, location zone 4,select No 2. Enter

Address Program 123, location zone 4,Select No 5. Enter

Diagram 2

Address Program 122, location zone 2,select No 2. Enter

Address Program 123, location zone 2,Select No 5. Enter

tam

per

12 V

Crow Alarm Panel

Diagram 1

GN

D

4

C

2

3

C

1

2

C

1

4

C

3

12 V

GN

D

ZONE 4

ZONE 2

Page 17: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

17

8.2k resistor

tam

per

12 V

Crow Alarm Panel

12 V

O V

Set up for zone 8 When Zones are being doubled

Latching smoke detector

Normally open

Address Program 122, location zone 8,select No’s 1 & 2. Enter

Address Program 123, location zone 8,Select No 5. Enter

Address Program 125, location zone 4,Select No 14. Enter

Diagram 1

GN

D

4

C

2

3

C

1

2.2k resistor

ADDING SMOKE DETECTOR TO ZONE

WHEN USING MORE THAN EIGHT ZONES

Enter into programming mode

Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 122 then Enter. Press 8 then Enter. 7 Will be lit up. Press 7,2,1

numbers 2 and 1 will light up and 7 will go out. Then Enter

Zones1 to 4 need a 4.7 resistor across the contacts.

Zones 5 to 8 need a 8.2k resistor across the contacts.

As per Diagram 1

• Press Program then 123 then Enter. Press 8 then Enter. Press 5 so it lights up then Enter.

This will set zone as fire zone.

• Press Program then 125 then enter. Then press 4 then Enter. 3 will flash then press 14 then

14 will flash back then Enter.

• Exit Program mode. Press Program then Enter.

ZONE 8

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

4.7k

Page 18: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

18

4.7k resistor

ADDING PANIC BUTTON TO ZONE

Enter into programming mode

Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

• Press Program then 122 then Enter.

Select the zone you wish to use, As Normally open. Then Enter.

• Numbers 1,6,7 will be lit up. Press 6,7,2 number 2 will light up and 6,7 will go out.

Then Enter. Zones1 to 8 need a 2.2k resistor across the contacts.

• Press Program then 123 then Enter.

Select the same number zone as above. Then Enter

Press 3 then Enter. This will set zone as 24 hour zone.

• Exit Program mode. Press Program then Enter.

As per Diagram 1

Set up for zone 4

Set up for zone 8 When Zones 4 is being used

as a zone

2.2k resistor

Panic Button

Normally

open

8.2k resistor

Panic Button

Normally

open

Address Program 122, location zone 4

select No 2 & 6 & 7 . 2 will light up 7 &

6 will go out then Enter.

Address Program 123, location zone 4

Select No 3 then Enter

tam

per

12 V

Crow Alarm Panel

Diagram 1

GN

D

4

O V

2

3

O V

1

tam

per

12 V

Crow Alarm Panel

Diagram 2

GN

D

4

O V

2

3

O V

1

Address Program 122, location zone 8

select No1 & 2 then Enter

Address Program 123, location zone 8

Select No 3 then Enter

Address Program 125, location zone

4,select No 14. Enter

Zone 8

ZONE 4

A B

C

D E F

12 V

TAMP TAMP

0 V

ALARM

ALARM

Zone 4

2.2k resistor

Page 19: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

19

PIN NUMBER CHANGING

ADD / CHANGE / DELETE USER NUMBERS

There is a Maximum 100 Users

Enter into programming mode

Installer’s code (000000) set by default • Press Program button then installers number (000000) then Enter.

You are now in programming mode. Program light will be flashing.

User 1

• Press Program then 1 then Enter, Then 1 then Enter. Then user number

(1 to 6 Digits in Length) then Enter. ( 123 is default )

User 1 is Master Code which can be used to change Codes, Clock, and Phone No’s

User 2

Press Program then 1 then Enter. Then 2 then Enter. Then user number

(1 to 6 Digits) then Enter.

User 3

Press Program then 1 then Enter. Then 3 then Enter. Then user number

(1 to 6 Digits) then Enter.

Users 4 to 100 can be added by following the steps above

CHANGE INSTALLERS NUMBER

Press Program then 25 then Enter. Then 1 then Enter.

Enter installer number (3 to 6 digits in Length) then Enter. (000000) default.

Delete User Number (LED KEYPAD)

Press Program then the user number location you want to delete (2 to 100) then Enter, then By-

pass then Enter.

Delete User Number (LCD KEYPAD)

Press Program then 1 Then Enter. Then the user number location you want to delete (2 to 100)

then Enter, then Control then 0 then Enter.

Defaulting System

Press Program then 200 then Enter. Then 10 then Enter.

Defaulting System numbers

Press Program then 200 then Enter. Then 9 then Enter. ( pin numbers & phone numbers)

ADDRESS USER No NUMBER

USER 1 1 1 123

USER 2 1 2

USER 3 1 3

USER 4 1 4

USER 5 1 5

USER 6 1 6

USER 7 1 7

USER 8 1 8

USER 9 1 9

User codes can be between

1 and 6 digits in length

Default

Page 20: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

20

SETTING THE CLOCK

Press Program then 26 then Enter then 1 then Enter then the time (24 hour time)

then Enter.

Press Program then 26 then Enter then 2 then Enter. Then the day

1=Sun, 2=Mon, 3=Tue, 4=Wed, 5=Thu, 6=Fri, 7=Sat, then Enter.

Press Program then 26 then Enter then 3 then Enter. Then the date (day / month / year)

DD/MM/YY

ENTRY & EXIT DELAY TIMES

Zone 1 is Set to entry and exit ( Default setting 20 seconds entry / 60 seconds exit.)

Change Entry Times ( Zone 1)

Press program then 144 then Enter. Then 1 then Enter. Then the time in seconds

(0-9999) then Enter.

Change Entry Times ( Zone 2)

Press program then 144 then Enter. Then 2 then Enter. Then the time in seconds

(0-9999) then Enter.

Change Entry Times ( Zone 3)

Press program then 144 then Enter. Then 3 then Enter. Then the time in seconds

(0-9999) then Enter.

To change any other zone entry time, follow steps above

Zones 2 to 8 Are Set To 0 Seconds for instance.

Change Exit Times Press Program then 60 then Enter. then 1 then Enter then the time in seconds

(0-255) then Enter.

Default Set for 60 Seconds

EXTRA SETTINGS

Setting Zones For Stay Mode

(1 to 4 are on by default)

Press Program then 122 then Enter. Then Press the zones you want in stay mode

(4 To 8) then Enter. Then press number 6 so it lights up then press Enter.

Setting Zones To Chime Zone (Disarmed) Press Program then 123 then Enter, Then press the zones to be chime zones then Enter.

Then press 7 so it lights up then Enter.

Wired Panic Alarm

Press Program then 122 then Enter. Then press the zone number you are using for this

type of alarm then Enter 1,6,7 will be light up press 6,7,2 number will light up 6,7 will

go out then Enter.

Press Program then 123 then Enter. Then press the zone number you are using for this

alarm then Enter press 3 then Enter. (this will set for 24 hour zone).

Exit programming mode. Press Program then Enter.

Page 21: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

21

MOBILE PHONE SETUP

Turn Dialler On

Press Program then 175 then Enter, Then press 1 then Enter. numbers 2,6,7, should be lit up,

Press 7 so it goes out. Press 1 so it lights up Then press Enter (Turns on dialler).

Press Program then 175 then Enter, Then press 5 then Enter. 168 will flash.

Press 0 then Enter.

( NOTE : The settings below will allow the alarm to call your mobile once and if not answered to move on to next

stored number )

FIRST PHONE NUMBER

Entering Phone Numbers

First Number

Press Program then 181 then Enter. Then Enter 1 Then Enter. Then press Phone Number (Up

to 16 Digits) then Enter.

Press Program then 182 then Enter. Then press 1 then Enter. 1will flash on .Then press 2 then

Enter.

Press Program then 183 then Enter. Then press 1 then Enter. 1,2,4 will be light up Then press ,4

then Enter.(1,2, will light up and 4, will go out)

Press Program then 184 then Enter. Then press 1 then Enter, 3 will flash . Press 1

and then press Enter

Press Program then 186 then Enter. Then press 1 then Enter,

1 = Report Mains Fail (Turn Off)

2 = Report Low Battery (Turn Off)

3 = Report Radio battery low (Turn Off)

4 = Report Line Failure (Turn Off)

5 = Report System Tamper (Leave On)

6 = Report keypad Tamper (Turn Off)

7 = Report Zone Tamper (Turn Off)

8 = Report Radio Tamper (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 187 then Enter. Then press 1 then Enter,

1 = Report Duress Alarm (Turn Off)

2 = Report Radio Alarm (Turn Off)

3 = Report Sensor Watch (Turn Off)

4 = Report Panic Alarm (Turn Off)

5 = Report Fire Alarm (Leave On)

6 = Report Medical Alarm (Turn Off)

7 = Report Pendant Alarm (Turn Off)

8 = Report Zone Bypasses (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

Page 22: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

22

FIRST PHONE NUMBER

CONTINUED

Press Program then 188 then Enter. Then 1 then Enter

1 = Report Arm/Disarm (Turn Off)

2 = Report Stay mode arm (Turn Off)

3 = Report Disarm activation (Turn Off)

4 = Report Stay activation (Turn Off)

5 = Report Stay mode (Turn Off)

6 = Report Program mode (Leave Off)

7 = Report 24 hours (Leave On)

8 = Report restores (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 189 then Enter. Then press 1 then Enter,

1 = Report latchkey (Leave Off)

2 = Report delinquent (Leave Off)

3 = Report tests (Turn Off)

4 = Report fuse failure (Turn Off)

5 = Report output fail (Turn Off)

6 = Report time change (Leave Off)

7 = Report keypad trouble (Leave Off)

8 = Report Zone rf jamming (Leave Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

MOBILE PHONE SETUP

Page 23: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

23

SECOND PHONE NUMBER

Entering Phone Numbers

Second Number

Press Program then 181 then Enter. Then Enter 2 Then Enter. Then press Phone Number (Up

to 16 Digits) then Enter.

Press Program then 182 then Enter. Then press 2 then Enter. 1 will flash on .Then press 2 then

Enter.

Press Program then 183 then Enter. Then press 2 then Enter. 1,2,4 will be lit up Then press 4

then Enter. (1,2, will light up and 4, will go out).

Press Program then 184 then Enter. Then press 2 then Enter, 3 will flash . Press 1

and then press Enter.

Press Program then 186 then Enter. Then press 2 then Enter.

1 = Report Mains Fail (Turn Off)

2 = Report Low Battery (Turn Off)

3 = Report Radio battery low (Turn Off)

4 = Report Line Failure (Turn Off)

5 = Report System Tamper (Leave On)

6 = Report keypad Tamper (Turn Off)

7 = Report Zone Tamper (Turn Off)

8 = Report Radio Tamper (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 187 then Enter. Then press 2 then Enter,

1 = Report Duress Alarm (Turn Off)

2 = Report Radio Alarm (Turn Off)

3 = Report Sensor Watch (Turn Off)

4 = Report Panic Alarm (Turn Off)

5 = Report Fire Alarm (Leave On)

6 = Report Medical Alarm (Turn Off)

7 = Report Pendant Alarm (Turn Off)

8 = Report Zone Bypasses (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

MOBILE PHONE SETUP MOBILE PHONE SETUP

Page 24: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

24

SECOND PHONE NUMBER

CONTINUED

Press Program then 188 then Enter. Then 2 then Enter

1 = Report Arm/Disarm (Turn Off)

2 = Report Stay mode arm (Turn Off)

3 = Report Disarm activation (Turn Off)

4 = Report Stay activation (Turn Off)

5 = Report Stay mode (Turn Off)

6 = Report Program mode (Leave Off)

7 = Report 24 hours (Leave On)

8 = Report restores (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 189 then Enter. Then press 2 then Enter.

1 = Report latchkey (Leave Off)

2 = Report delinquent (Leave Off)

3 = Report tests (Turn Off)

4 = Report fuse failure (Turn Off)

5 = Report output fail (Turn Off)

6 = Report time change (Leave Off)

7 = Report keypad trouble (Leave Off)

8 = Report Zone jamming (Leave Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

MOBILE PHONE SETUP

Page 25: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

25

THIRD PHONE NUMBER

Entering Phone Numbers

Third Number

Press Program then 181 then Enter. Then Enter 3 Then Enter. Then press Phone Number (Up

to 16 Digits) then Enter.

Press Program then 182 then Enter. Then press 3 then Enter. 1will flash on .Then press 2 then

Enter.

Press Program then 183 then Enter. Then press 3 then Enter. 1,2,4 will be lit up Then press 4

then Enter. (1,2, will light up and 4, will go out).

Press Program then 184 then Enter. Then press 3 then Enter, 3 will flash . Press 1

and then press Enter.

Press Program then 186 then Enter. Then press 3 then Enter,

1 = Report Mains Fail (Turn Off)

2 = Report Low Battery (Turn Off)

3 = Report Radio battery low (Turn Off)

4 = Report Line Failure (Turn Off)

5 = Report System Tamper (Leave On)

6 = Report keypad Tamper (Turn Off)

7 = Report Zone Tamper (Turn Off)

8 = Report Radio Tamper (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 187 then Enter. Then press 3 then Enter,

1 = Report Duress Alarm (Turn Off)

2 = Report Radio Alarm (Turn Off)

3 = Report Sensor Watch (Turn Off)

4 = Report Panic Alarm (Turn Off)

5 = Report Fire Alarm (Leave On)

6 = Report Medical Alarm (Turn Off)

7 = Report Pendant Alarm (Turn Off)

8 = Report Zone Bypasses (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

MOBILE PHONE SETUP

Page 26: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

26

THIRD PHONE NUMBER

CONTINUED

Press Program then 188 then Enter. Then 3 then Enter

1 = Report Arm/Disarm (Turn Off)

2 = Report Stay mode arm (Turn Off)

3 = Report Disarm activation (Turn Off)

4 = Report Stay activation (Turn Off)

5 = Report Stay mode (Turn Off)

6 = Report Program mode (Leave Off)

7 = Report 24 hours (Leave On)

8 = Report restores (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 189 then Enter. Then press 3 then Enter,

1 = Report latchkey (Leave Off)

2 = Report delinquent (Leave Off)

3 = Report tests (Turn Off)

4 = Report fuse failure (Turn Off)

5 = Report output fail (Turn Off)

6 = Report time change (Leave Off)

7 = Report keypad trouble (Leave Off)

8 = Report Zone jamming (Leave Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

MOBILE PHONE SETUP

Page 27: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

27

FOURTH PHONE NUMBER

Entering Phone Numbers

Fourth Number

Press Program then 181 then Enter. Then Enter 4 Then Enter. Then press Phone Number (Up

to 16 Digits) then Enter.

Press Program then 182 then Enter. Then press 4 then Enter. 1will flash on .Then press 2 then

Enter.

Press Program then 183 then Enter. Then press 4 then Enter. 1,2,4 will be lit up Then press 4

then Enter. (1,2, will light up and 4, will go out).

Press Program then 184 then Enter. Then press 4 then Enter, 3 will flash . Press 1

and then press Enter.

Press Program then 186 then Enter. Then press 4 then Enter.

1 = Report Mains Fail (Turn Off)

2 = Report Low Battery (Turn Off)

3 = Report Radio battery low (Turn Off)

4 = Report Line Failure (Turn Off)

5 = Report System Tamper (Leave On)

6 = Report keypad Tamper (Turn Off)

7 = Report Zone Tamper (Turn Off)

8 = Report Radio Tamper (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 187 then Enter. Then press 4 then Enter.

1 = Report Duress Alarm (Turn Off)

2 = Report Radio Alarm (Turn Off)

3 = Report Sensor Watch (Turn Off)

4 = Report Panic Alarm (Turn Off)

5 = Report Fire Alarm (Leave On)

6 = Report Medical Alarm (Turn Off)

7 = Report Pendant Alarm (Turn Off)

8 = Report Zone Bypasses (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

MOBILE PHONE SETUP

Page 28: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

28

FOURTH PHONE NUMBER

CONTINUED

Press Program then 188 then Enter. Then 4 then Enter

1 = Report Arm/Disarm (Turn Off)

2 = Report Stay mode arm (Turn Off)

3 = Report Disarm activation (Turn Off)

4 = Report Stay activation (Turn Off)

5 = Report Stay mode (Turn Off)

6 = Report Program mode (Leave Off)

7 = Report 24 hours (Leave On)

8 = Report restores (Turn Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Note: You Can Not Turn Off The Alarm Activity Reporting.

Press Program then 189 then Enter. Then press 4 then Enter,

1 = Report latchkey (Leave Off)

2 = Report delinquent (Leave Off)

3 = Report tests (Turn Off)

4 = Report fuse failure (Turn Off)

5 = Report output fail (Turn Off)

6 = Report time change (Leave Off)

7 = Report keypad trouble (Leave Off)

8 = Report Zone rf jamming (Leave Off)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter

MOBILE PHONE SETUP

Page 29: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

29

MONITORING STATION SET UP

Press Program then 175 then Enter, Then press 1 then Enter. Numbers 2,6,7, are lit up.

Press 1 so it lights up. Then press Enter (Turns on dialler).

Test call time of the day: Press Program then 175 then Enter, Then press 4 then Enter.

Enter the time of the day to send the call in 24 hour time HH.MM

(0430 the time is set by default).

Test call day times: Press Program then 175 then Enter, Then press 5 then Enter. 1,6,8 will flash .

Press 24 (every24 hours it will send a test call) Then Enter.

(168 set by default: once a week)

Monitoring account code: Press Program then 62 then Enter. Then press 1 then Enter.

Then Enter the account number then Enter. (Account number from the monitoring company).

Entering Phone Numbers

Primary Number

Press Program then 181 then Enter. Then Enter 1 Then Enter. Then press Phone Number

(Up to 16 Digits) then Enter.

Press Program then 184 then Enter. Then press 1 then Enter, Number 3 will flash . Then Press 6

then press Enter.

Check with monitoring company on what they want on

Press Program then 186 then Enter. Then 1 then Enter.

1 = Report Mains Failure (Leave On)

2 = Report Low battery (Leave On)

3 = Report Wireless Battery (Leave On)

4 = Report Line Failure (Leave On)

5 = Report System Tamper (Leave On)

6 = Report Key pad Tam (Leave On)

7 = Report Zone Tamper (Leave On)

8 = Report Radio Tamper (Leave On)

Press Program then 187 then Enter. Then 1 then Enter.

1 = Report Duress Alarm (Leave On)

2 = Report Radio (Leave On)

3 = Report Sensor watch (Leave On)

4 = Report panic (Leave On)

5 = Report Fire (Leave On)

6 = Report Medical (Leave On)

7 = Report Radio Panic (Leave On)

8 = Zone bypasses (Leave On)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Page 30: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

30

MONITORING STATION SET UP CONTINUED

Press Program then 188 then Enter. Then 1 then Enter

1 = Report Open / Close (Turn Off)

2 = Report Stay Open / Close (Turn Off)

3 = Report Open after Alarm (Turn Off)

4 = Report Stay Open after Alarm (Turn Off)

5 = Report Alarm in Stay (Turn Off)

6 = Report Access programming (Leave Off)

7 = Report 24 hr alarm (leave On)

8 = Report Restores (Leave On)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Press Program then 189 then Enter.

1 = Report latch (Turn Off)

2 = Report Delinquent (Turn Off)

3 = Report Tests (Leave On)

4 = Report Fuse Failure (Leave On)

5 = Report output fails (Leave On)

Check With Your Monitoring Station What They Need On.

Refer to Page 41-42 of the Technician’s Handbook

Exit Programming Mode

Press Program then Enter.

Page 31: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

31

BACK UP NUMBER

Press Program then 181 then Enter. Then Enter 2 Then Enter. Then press Phone Number

(Up to 16 Digits) then Enter.

Press Program then 184 then Enter. Then press 2 then Enter, Number 3 will flash . Then Press 6

then press Enter

Enter the same as the primary number

Press Program then 186 then Enter. Then 1 then Enter.

1 = Report Mains Failure (Leave On)

2 = Report Low battery (Leave On)

3 = Report Wireless Battery (Leave On)

4 = Report Line Failure (Leave On)

5 = Report System Tamper (Leave On)

6 = Report Key pad Tam (Leave On)

7 = Report Zone Tamper (Leave On)

8 = Report Radio Tamper (Leave On)

Press Program then 187 then Enter. Then 1 then Enter.

1 = Report Duress Alarm (Leave On)

2 = Report Radio (Leave On)

3 = Report Sensor watch (Leave On)

4 = Report panic (Leave On)

5 = Report Fire (Leave On)

6 = Report Medical (Leave On)

7 = Report Radio Panic (Leave On)

8 = Zone bypasses (Leave On)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Press Program then 188 then Enter. Then 1 then Enter

1 = Report Open / Close (Turn Off)

2 = Report Stay Open / Close (Turn Off)

3 = Report Open after Alarm (Turn Off)

4 = Report Stay Open after Alarm (Turn Off)

5 = Report Alarm in Stay (Turn Off)

6 = Report Access programming (Leave Off)

7 = Report 24 hr alarm (leave On)

8 = Report Restores (Leave On)

Press the numbers that you want Off so the lights are Out.

The lights that are On are the only reports that you will get. Then press Enter.

Press Program then 189 then Enter.

1 = Report latch (Turn Off)

2 = Report Delinquent (Turn Off)

3 = Report Tests (Leave On)

4 = Report Fuse Failure (Leave On)

5 = Report output fails (Leave On)

Check With Your Monitoring Station What They Need On.

Refer to Page 41-42 of the Technician’s handbook.

Exit Programming Mode

Press Program then Enter.

Page 32: Crow ST Runner 4-8 Zones Quick Setup Diagrams V1.2

32

Siren

Red to Output 1

Strobe

White To Output

2

Power

Brown To 12 volt

2.2 K RESISTOR

PIR No 1 Indoor Siren

Black to

Output 1

In Door Siren

Red to

12 Volt

tam

per

12 V

Crow Runner Alarm Panel

4 &

8

C

C

GN

D

3 &

7

2 &

6

1 &

5

12 V

POS

NEG

CLK

DAT

LIN

GN

D

IN

AC

EARTH

16 VOLT

Power Supply

Key Pad

Runner

GN

D

12 V

2

1

A B C D E F

12 V

TA

MP

TA

MP

0 V

ALA

RM

ALA

RM

4.7k 2.2k