Cross Reference RA Part Number: PN-D10560...contacts can be selected. Example: Code 90011 indicates...
Transcript of Cross Reference RA Part Number: PN-D10560...contacts can be selected. Example: Code 90011 indicates...
-
Product Details and Certifications
Cross Reference RA Part Number: PN-D10560Product: 509-BOIDescription: NEMA FULL Voltage Non-Reversing Starter, SIZE 1, 415V 50Hz, Open
Type without Enclosure, with Eutectic Alloy Overload Relay, 3 Power Poles
Representative Photo Only (actual product may vary based on configuration sections)
CONTACTOR DATABulletin Number 509 NEMA Full Voltage Non-Reversing StartersNEMA Size NEMA 1Enclosure Type Open TypeCoil Voltage 415V 50HzPhases 3 PhasesOverload Relay Eutectic Alloy
ASSEMBLYAssembly Modular Kit
CERTIFICATIONS AND APPROVALSNEMA/EEMACULCSAABSUSCGEN/IECCEFor UL Certifications Directory: http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
JLNERIHighlight
JLNERIRed_Pointed_Right
-
NEMA AC Contactors
Bulletin 500 500F
Description Top-wired contactor Feed-through contactor
NEMA Size 00…9 0…5
ContinuousAmpere Rating [A] 9…2250 18…270
Availability
NEMA size 0…4, open typeModular kits and components
NEMA size 00, 5…9, open typeFactory assembled
NEMA size 00…9, enclosedFactory assembled
NEMA size 0…4, open typeModular kits and components
NEMA size 5, open typeFactory assembled
NEMA size 0…5, enclosedFactory assembled
Enclosures(NEMA Type) 1, 3R/4/12, 4/4X, 7, and 9 —
Standards
� NEMA/EEMAC ICS2 (IndustrialControls and Systems)
� UL 508� CSA C22.2, No. 14� ABS 4/5.115� USCG 46 CFR 111.70� IEEE 45
� NEMA/EEMAC ICS2 (IndustrialControls and Systems)
� UL 508� CSA C22.2, No. 14� ABS 4/5.115� USCG 46 CFR 111.70� IEEE 45
Certifications
� UL Listed (File No. E3125; Guide No.NLDX)
� (File No. E10314; Guide No. NPKR)� CSA Certified (LR1234)� CE Marked (Per EN 60947)� American Bureau of Shipping (ABS)
� UL Listed (File No. E3125; Guide No.NLDX)
� (File No. E10314; Guide No. NPKR)� CSA Certified (LR1234)� CE Marked (Per EN 60947)� American Bureau of Shipping (ABS)
Product Selection Page 1-31 Page 1-36
NEMA Starters
Bulletin 505 509 520
Description Reversing starters Non-reversing starters Multi-speed starters
3-Phase 600V, 3-Pole Overload Protection
NEMA Size 00…8 00…9 0…7
ContinuousAmpere Rating 9…1215 A 9…2250 A 18…810 A
Availability All sizesFactory assembled
NEMA size 0…4, open typeModular kits and components
NEMA size 00, 5…9, open typeFactory assembled
NEMA size 00…9, enclosedFactory assembled
All sizesFactory assembled
Enclosure Type 1, 3R/4/12, 4/4X, 7, and 9 1, 3R/4/12, 4/4X, 7, and 9 1, 3R/4/12, 4/4X, 7, and 9
Standards
� NEMA/EEMAC ICS 2(Industrial Controls and Systems)
� UL 508� CSA C22.2, No. 14� ABS 4/5.115� USCG 46 CFR 111.70
� NEMA/EEMAC ICS 2(Industrial Controls and Systems)
� UL 508� CSA C22.2, No. 14� ABS 4/5.115� USCG 46 CFR 111.70
� NEMA/EEMAC ICS(Industrial Controls and Systems)
� UL 508� CSA C22.2, No. 14� ABS 4/5.115
Certifications
� UL Listed (File No. E3125; Guide No. NLDX)� CSA Certified (File LR 1234)� CE Marked (per EN 60947-4-1)� American Bureau of Shipping (ABS)� Hazardous Location: UL Listed (File No. E10314), CSA Certified (File No. LR 11924)
� UL Listed (File No. E3125; Guide No. NLDX)� CSA Certified (File LR 1234)� Hazardous Location: UL Listed (File No.
E10314), CSA Certified (File No. LR 11924)
ProductSelection Page 1-39 Page 1-46 Page 1-53
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Product Overview
1-29
Bulletin 300, 305, 309, 500, 500F, 505, 509, 520
NEMA AC Contactors and Starters
Bulletin 300, 305, 309
Features
� Modular line of NEMAcontactors & starters
� Space saving design� Electronic & conventional coils� DIN Rail mountable� Common accessories� Guarded terminals
NEMA Size 0…5
DIN RailMountable �
CertificationscULus Listed (File No. E41850,
Guide No. NLDX, NLDX7)CE Marked (per EN60947-4-1)
ProductSelection Page 1-60
NEMA Compact AC Contactors andStarters
www.ab.com/catalogs Preferred availability cat. nos. are bbold.
Publication A117-CA001A-EN-P
jlneriHighlight
jlneriRed_Pointed_Down
-
Bulletin 509
NEMA Non-Reversing Starters
Bulletin 509 Open Type Full Voltage Starter� Feed-through construction� Starter can be field wired for single- or three-phase applications
NEMA sizes 0…4� Available as components or as a modular kit for faster delivery� Product selection can be done via two options:
− Ordering a complete kit− Ordering individual components
� Starter includes a 120V AC coil and (1) N.O. auxiliary contact, asstandard
NEMA sizes 00, 5…9� Available as factory assembled
NEMA sizes 00…9 (Enclosed)� Available as factory assembled
Bulletin 509, Size 1with Eutectic Alloy
Overload RelayOpen Type without Enclosure
Table of Contents
Product Selection ...... 1-46Modifications............... 1-106Accessories.................. 1-111Specifications.............. 1-126ApproximateDimensions................... 1-133Heater ElementSelection ....................... 1-167
Standards ComplianceNEMA/EEMAC ICS 2UL 508CSA C22.2 No.14ABS 4/5.115 — American Bureau of ShippingUCSG 46 CFR 111.70EN/IEC 60947-4-1CE Marked
CertificationsCSA Certified (LR1234)UL Listed (File No. E3125, Guide No. NLDX)Hazardous Location: UL Listed (File No. E10314), CSA Certified (LR11924)
Catalog Number ExplanationExample Cat. No.
eEutectic Overload Relay
Code Description
blank Eutectic Alloy
E1 Plus Solid-State Overload Relay
Code NEMASizeFull Load Current
Adjustment Range [A]
3-Phase
A2C 0,1 0.2…1.0
A2E 0,1 1.0…5.0
A2F 0,1 3.2…16
A2G 0,1,2 5.4…27
A2J 1,2,3 9…45
A2L 3 18…90
A2M 4 30…150
A2N 5 60…300
A2R 6 120…600
A2T 7 256…810
A2U 8 384…1215
A2V 9 800…2250
1-Phase
S2E 0,1 1.0…5.0
S2F 0,1 3.2…16
S2G 0,1,2 5.4…27
S2J 1,2,3 9…45
S2L 3 18…90
aBulletin No.
BulletinNo. Description
509 Top-wired contactor
509DC Top-wired contactor (DCvoltage)
bNEMA Size
Code Description
T 00
A 0
B 1
C 2
D 3
E 4
F 5
G 6
H 7
J 8
K 9
cNEMA Enclosure Type
Code Type
A Type 1
C Type 4X (stainless steel)
H Type 3R, 7 & 9 bolted
J Type 3R/4/12
O No enclosure
dNominal Coil Voltage
Code Voltage Frequency
A 220V240V50 Hz60 Hz
B 440V480V50 Hz60 Hz
C 550V600V50 Hz60 Hz
D 110V120V50 Hz60 Hz
F 277V 60 Hz
H 200…208V 60 Hz
I 415V 50 Hz
J 24V 50/60 Hz
N 380V 50 Hz
VL 24V DC ⎯
VG 125…250VDC ⎯
fFactory Installed
Modifications/Options
For detailed information, seeModifications on page 1-106.
orOptions
Code Description
9(1) N.O. Auxiliary Contact
for use on EutecticOverload Relay
9A(1) N.C. Auxiliary Contact
for use on EutecticOverload Relay
17 Surge Suppressor for 120or 240V AC Coil
90 (1) N.O. Auxiliary Contactfor use on Contactor�
91 (1) N.C. Auxiliary Contactfor use on Contactor�
� Up to (6) combinations of auxiliarycontacts can be selected.Example: Code 90011 indicates(2) N.O. and (2) N.C. contacts.
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. See page1-167 for heater element selection tables.
Note: All enclosed non-combination starters are supplied with external reset as standard, except forstarters with E3 overload relay.
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Product Overview/Cat. No. Explanation
1-45
509 – B O D – A2E – 17a b c d e f
www.ab.com/catalogs Preferred availability cat. nos. are bbold.
Publication A117-CA001A-EN-P
jlneriText Box
jlneriText Box
jlneriRed_Pointed_Right
jlneriHighlight
jlneriHighlight
jlneriHighlight
jlneriRed_Pointed_Right
jlneriRed_Pointed_Right
jlneriRed_Pointed_Right
JLNERIText Box
JLNERITypewritten TextI
JLNERIHighlight
JLNERIRed_Pointed_Right
JLNERIHighlight
JLNERIRed_Pointed_Right
-
Bulletin 509
NEMA Non-Reversing Starters
Product Selection of NEMA sizes 0…4 by Modular Kits
Base ContactorIncludes a 120V AC coil and (1) N.O. auxiliary contactor as standard.Heater Elements — Starters with eutectic alloy overload relay require 3 heater elements. See page 1-167 for heater element selection tables.
NEMASize
ContinuousAmpere Rating
[A]
Maximum Horsepower RatingFull Load Current Must Not Exceed “Continuous Ampere Rating”
1-Phase Motor Voltage 3-Phase Motor Voltage3 Power Poles � 600V AC
Maximum � 60 Hz
115V 230V 200V 230V50 Hz
380…415V 460…575V Cat. No.
00 9 1/3 1 1.5 1.5 2 2 ♣0 18 1 2 3 3 5 5 509-AO⊗-✪
1 27 2 3 7.5 7.5 10 10 509-BO⊗-✪
2 45 3 7.5 10 15 25 25 509-CO⊗-✪
3 90 7.5 15 25 30 50 50 509-DO⊗-✪
4 135 — — 40 50 75 100 509-EO⊗-✪5 270 — — 75 100 150 200 ♣6 540 — — 150 200 300 400 ♣7 810 — — — 300 600 600 ♣8 1215 — — — 450 900 900 ♣9 2250 — — — 800 1600 1600 ♣
♣ See page 1-48 for NEMA size 00, 5…9 open type starters and NEMA size 00…9 enclosed starters.
⊗ Coil Voltage CodeThe cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 509-BO⊗-✪becomes Cat. No. 509-BOD-✪.
[V] 24 110 120 125 208 220 240 250 277 380 415 440 480 550 600
AC, 50 Hz J D — — — A — — — N I B — C —
AC, 60 Hz J — D — H — A — F — — — B — C
DC� VL — — VG — — — VG — — — — — — —
� DC voltage code is only available for NEMA sizes 0…3. When ordering a DC voltage code (VL or VG), add "DC" to the catalog number. Example: Cat. No.509DC-BOVL.
Note: The base contactor includes a 120V AC coil as standard. For all other voltages, a second coil will be included in the modular kit forfield swap out.
✪ Overload Relay CodeUse to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete,select an overload relay code from the table below to complete the cat. no. Example: Cat. No. 509-BOD-✪ becomes Cat. No. 509-BOD-A2E.
Full Load CurrentRange [A]
NEMA Size (3-Phase) NEMA Size (1-Phase)
0 1 2 3 4 0 1 2 3
0.2…1.0 A2C A2C — — — — — — —
1.0…5.0 A2E A2E — — — S2E S2E — —
3.2…16 A2F A2F — — — S2F S2F — —
5.4…27 A2G A2G A2G — — S2G S2G S2G —
9…45 — A2J A2J A2J — — S2J S2J S2J
18…90 — — — A2L — — — — S2L
30…150 — — — — A2M — — — —
Options for Modular Kit
Code Description
9 (1) N.O. Auxiliary Contact for use on Eutectic Overload Relay
9A (1) N.C. Auxiliary Contact for use on Eutectic Overload Relay
17 Surge Suppressor for 120 or 240V AC Coil
90 (1) N.O. Auxiliary Contact for use on Contactor�
91 (1) N.C. Auxiliary Contact for use on Contactor�
� Up to (6) combinations of auxiliary contacts can be selected.Example: Code 90011 indicates (2) N.O. and (2) N.C. contacts.
Example: Cat. No. 509-BOD-A2F-17-901 includes a NEMA size 1, 3-pole, contactor with a 120V AC coil, surge suppressor, and (2) auxiliarycontacts, (1) N.O. and (1) N.C.
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Product Selection — Modular Kit
1-46www.ab.com/catalogs Preferred availability cat. nos. are bbold.
Publication A117-CA001A-EN-P
jlneriHighlight
jlneriHighlight
jlneriRed_Pointed_Left
JLNERIHighlight
JLNERIHighlight
JLNERIHighlight
JLNERIRed_Pointed_Right
-
Knowledgebase technotes can be found at http://support.rockwellautomation.com/
Operating Coils
Coil Repair Part Number Catalog Number Suffix Code
AC Volts Hz Size 0-1 Size 2 Size 3 Size 4 Size 5 (Series L)
J 24 60 CB013 CC013 CD013 NA Not Available K 24 50 CB407 CC407 CD407 NA AF407D 115-120 60Hz, 110V 50Hz CB236 CC236 CD236 CE236 AF236 S 110-115 50 CB322 CC322 CD322 CE322 AF322H 200-208 60 CB249 CC249 CD249 CE249 AF249P 220-230 50 CB339 CC339 CD339 CE339 AF339A 230-240 60 CB254 CC254 CD254 CE254 AF254T 230-240 50 CB342 CC342 CD342 CE342 AF342F 277 60 CB260 CC260 CD260 CE260 AF260N 380 50 CB354 CC354 CD354 CE354 AF354
KN 380-400 50 CB390 CC390 CD390 CE390 AF390I 415 50 CB357 CC357 CD357 CE357 AF357Q 440-460 50 CB360 CC360 CD360 CE360 AF360B 460-480 60 CB273 CC273 CD273 CE273 AF273M 500 50 CB364 CC364 CD364 CE364 AF364C 575-600 60 CB278 CC278 CD278 CE278 AF278
Size 5 Overload Relay Assembly with Current Transformers – Repair Part Number 42452-800-01
Components from Part Number 42452-800-01 Part Number Nylon Spacer Insulator 42450-031-01 Overload Relay 592-BOV16 Overload Relay Mounting Plate (not labeled) 42450-028-02 Lug 42450-804-01Nylon Standoff (qty 3 req’d) 42450-029-01 Current Transformer Module 42450-032-01 Current Transformer Module Mounting Plate (not labeled) 42450-009-02 Current Transformer (300 to 5A ratio) qty 3 req’d X-241563