CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338...

12
IMPLASSIC FT3 IMPLASSIC FTP IMPLOGIC ® AT IMPLASSIC FT2 SHORT IMPLOGIC ® GII FOR IMPLANT LINES 2020 TRANSMUCOSAL ABUTMENT SHAPE TISSUE EFFECT

Transcript of CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338...

Page 1: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

IMPLASSIC FT3IMPLASSIC FTPIMPLOGIC® ATIMPLASSIC FT2 SHORTIMPLOGIC® GI I

F O R I M P L A N T L I N E S

2020

T R A N S M U C O S A L A B U T M E N T

SHAPE TISSUE EFFECT

Page 2: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

CONTENT INDEX

TRANSMUCOUS ABUTMENTFEATURES AND BENEFITS

TECHNICAL FEATURES

REFERENCE CODES

3

4

5

OVERVIEW PROSTHETICCOMPONENTS

INSTRUMENTS

RATCHETCLEANING AND MAINTENANCE

6

8

8

PRELIMINARY INDICATIONSFOR SURGICAL INSTRUMENT USE

INSTRUMENTS WARNING and LEGENDS

BIBLIOGRAPHY andSALE CONDITIONS

9

10

11

Page 3: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

It simplifies the prosthetic procedure for the benefit of the

peri-implant tissue, since it moves the implants’engagement

platform from internal to external connection, from the bone level

to the soft tissues level.Not suitable for single

prostheses.

Once positioned, according to the prosthetic emergency, it is no

longer removed, thus guaranteeing the stability of the

surrounding peri-implant tissues.

By acting on the transmucosal abutment with a 30Ncm torque, a perfect intimacy of the abutment-implant interface is ensured. This prevents migration and bacterial colonization on the “pumping effect” action.

It can be prosthesized both with immediate loading, in a variety of secondary components suitable for the planned prosthetic project, and with deferred loading, preserved by a protective cap that leaves the soft tissue undisturbed for an optimal tissue adaptation and a complete implant integration. The external connection platform offers a wide range of prosthetic solutions to better manage the prosthetic needs of each project.

Available for FTP, ImpLassic And ImpLogic® implant connections, in different types of transgingival height.

TRANSMUCOSAL ABUTMENT

New prosthetic component that promotes the conditioning of peri-implant tissues, guaranteeing ample flexibility during the prosthetic phases.

FEATURES AND BENEFITS

3

TRA

NS

MU

CO

US

AB

UTM

ENT

FEA

TURE

S A

ND

BEN

EFIT

S

Page 4: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

TECHNICAL FEATURESTE

CH

NIC

AL

FEA

TURE

S

4

Vertical and horizontal gap reduced to a minimum, thus minimizing the rotation between the components and the inflammatory infiltrate area, one of the major causes of peri-implant bone resorption. A lot of scientific literature produced in the 1990s by Paul Bynon in the United States, considers valid a matching between implant and abutment that does not exceed 4° of rotation.Working with minimum tolerances and making tight checks, Dental Tech manages to obtain a rotation between the parts in question ranging from 0.18 ° to 0.93 °, ensuring excellent stability of the connection and excellent mechanical sealing of the prosthetic screw.

0.18° 0.93°

SEM HV: 20.00 kVSEM MAG: 66 x

WD: 31.21 mmDet: SE DetectorView field: 4.53 mm

VEGA\\TESCAN Dental Tech

1 mm

1 mm

VEGA\\TESCAN Dental Tech

SEM HV: 20.00 kVSEM MAG: 76 x

WD: 27.45 mmDet: SE DetectorView field: 3.95 mm

Hexagonal platformø 4,1 mm standard

Zona A Zona B

Page 5: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

H height mmImpLassic FTP Implant Line

Height (H) mm REF

003335003336003338

2

3,5

4,5

Height (H) mm REF

003350003351

2

3,5

Height (H) mm REF

BTA3710BTA3725

2

3,5

Altezza (H) mm REF

60.9944

*Prosthetic screw included and available as a replacement (REF VBT3700)

*Prosthetic screw included and available as a replacement (REF VBT3700)

*Prosthetic screw included and available as a replacement (REF VBT3700)

H height mmImplassic Ø 3.25 Implant Line

H height mmImplogic® and Implassic Ø 3.75 Implant Lines

H

H

H

REF

VBT3700

HEALING CAP

TRANSMUCOSAL ABUTMENT

PROSTHETIC SCREW

Warning Transmucosal abutments in combination with the prosthetic components must always use the prosthetic screw VBT3700

Ti5

Ti5

Ti5

REFERENCE CODES

5

REFE

REN

CE

CO

DES

Page 6: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

COMPONENTS FOR IMPRESSIONS AND MODELS

IMPLANT ANALOG

REF

HLA4100

PICK-UP IMPRESSION COPING

Ti5

*VHTP5010 *VHTP2128

Ti5

Ti5Included in the package REF HFF2010. With the Transmucosal Abutment it must be replaced with REF VBT3700, also sold individually as a replacement.

FIXING SCREWPROSTHETIC COMPONENTS

Ti5FIXING SCREW

TEMPORARY STRAIGHT ABUTMENT

ANGLED ABUTMENT

Ø Peek

20Ncm Torque adapter REF TW0001

H

REF

HKS41303

ØH

5

STRAIGHT ABUTMENT Ti5

20Ncm Torque adapter REF TW0001

REF

HSA0041

Ø

4.1

REF

HSA41151,5

ØH

5

REF

HSA41303

ØH

5

Ø

Ø

Ø

H

Ti5

H

Ø

H

Ø

15° 25°

REF

HPA1541

HPA4121

HPA3041

HPA4123

41/15°

41/25°

41/15°

41/25°

1,5

1,5

3

3

5

5

5

5

H Ø ML

20Ncm Torque adapter REF TW0001

TEMPORARY ABUTMENT

Peek

REF

HKE4160 HKR0041

E

R

ML

CYLINDER

REF

HPP0060 HPC4100

E

R

ML

Ti5

GOLD ABUTMENT

REF

HGE6010 HRR0410

Au

Pmma

CASTABLE ABUTMENT

REF

HPE4160HPR0041

Pmma

while stocks last

Included in the package REF VHTP5010 and REF VHTP2128 With the Transmucosal abutment, use ONLY the REF VHTP2128 with shorter thread, also sold individually as a replacement.

OVERVIEW PROSTHETIC COMPONENTSO

VER

VIE

W P

ROS

THET

IC C

OM

PON

ENTS

6

REF

HTC4110 Cylindrical

Page 7: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

CAD CAM COMPONENTS

ROTATIONAL BONDING BASE

REF

BSRHEX

Ti5

*HFF2010

BONDING BASE

REF

BSTHEX

Ti5

*HFF2010

DIGITAL ANALOG

Ti5

SCAN ABUTMENT

Ti5

REF

60.992REF

SCANHEAnalog for digital models, specific for applications through the manufacture of models made with 3D printing/prototyping. Thecharacteristic shape with rounded edges, allows easy insertion into the model seat, without interference and friction with the resinous material of the models.The apical screw allows to always obtain a total working stability.This prosthetic component must be used through the Dental Tech Libraries.

*HFF2010

Suitable for digital CAD-CAM technique, for intraoral and laboratory scans.For single screwed and cemented elements.For multiple cemented elements.

It is necessary to match up the smaller portion of the Scan Abutment, which is alwaysoriented on the hexagonal side of the connection, with the side of the external square shape of the analogous digital body.

WARNINGDO NOT orient the ScanAbutment in the unsuitableand aligned secondary position

DIGITAL ANALOGUE - INDICATIONS OF USE

CORRECT POSITIONG

Ti5Included in the package REF HFF2010. With the Transmucosal Abutment it must be replaced with REF VBT3700, also sold individually as a replacement.

FIXING SCREW

OVERVIEW PROSTHETIC COMPONENTS

7

OV

ERV

IEW

PRO

STH

ETIC

CO

MPO

NEN

TS

Digital CAD-CAM and Traditional Bonding technique,For single screwed and cemented elements.For multiple cemented elements.

Digital CAD-CAM and Traditional Bonding technique,For multiple screwed and cemented elements.

Page 8: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

B

DYNAMOMETRIC RATCHET CLEANING AND MAINTENANCE REF CCD070

ISO CONNECTION FOR RATCHET

Lenght (L) mm REF

ISO3707

HEX SCREWDRIVER

INSTRUMENTSIN

STR

UM

ENTS

8

ShortLong

Lenght (L) mm

8,8

14,8

ShortLong

ADAPTOR FOR FASTENING SCREWS

HEX CA DRIVER

(L) mm REF

GMX100GMM250001152

4,5

11,5

18

MicroExtra ShortLong

DYNAMOMETRIC RATCHETREF CCD070

The dynamometric ratchet, after each use, must be disassembled for cleaning. This maintenance operation does not require any tools.Completely unscrew the screw (A), remove the whole pawl (B) and then the flexible dynamometric bar (C). Once disassembled, clean according to the instructions for use and maintenance attached to the device, brush with non-metallic rigid bristles, even in hollow areas with pipe cleaner for a complete removal of biological residues.

Once the cleaning and disinfection phase has been completed, reassemble the ratchet using the reverse disassembly procedure, making sure to match the pin (D) in the housing dedicated.

Page 9: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

PRELIMINARY INDICATIONSFOR SURGICAL INSTRUMENT USE

9

PREVENTIONBesides correct and continuous long-term maintenance, wear and tear of the instruments can also be prevented and slowed down. In the first place every instrument must only be used for the envisaged and indicated use.The instruments used must be cleaned immediately after the end of surgery. Remove residue and encrustations only with soft brushes and NOT with metal brushes.When envisaged, disassemble the instruments and deeply clean the cavity. The devices must be fully immersed in the most appropriate detergents or disinfectants for the material, and left to rest for a period of time that never exceeds the manufacturer’s instructions.After disinfecting them, rinse thoroughly with water and dry the devices with a clean and dry cloth. Complete with a jet of compressed air.

PACKAGING AND STERILITY• Dental Tech tools are supplied as non sterile in heat -sealed Pouches in containing the leaflet. • Dental Tech tools can be used again and therefore it has to be washed and sterilised prior to their usage.

Dental Tech validated the following cleansing and disinfection method:

MANUAL CLEANING• Just after the use of Dental Tech equipment, place the equipment into a container with a peracetic acid based solution at concentration of 2% (NO GLUTARALDEHYDE OR SODIUM HYPOCHLORITE ), as long as 18 minutes. • After-ward rinse carefully.

MANUAL DISINFECTION• Place the equipment into a container with a peracetic acid based solution at concentration of 4% (NO GLUTARALDEHYDE OR SODIUM HYPOCHLORITE ), as long as 15 minutes.• Rinse generously • Examine the equipment and make sure there are no organic remains. Carefully scrub the outer parts with a non-metal bristled brush.

MANUAL RINSE• Place the equipment into ultrasound bath, and wash it for approx. 18 minute and then rinse carefully.

DRY• Perfectly dry the equipment, seal it individually with material suitable for moist heat sterilisation.

STERILIZATION• Dental Tech validated the following Autoclave moist heat sterilization cycle: 3 minutes - 134 °C

• Since Dental Tech tools are manufactured in different materials, they shall be washed and sterilized one by one.

CHECKAfter the cleaning phases, check that none of the instruments presents signs of corrosion, contamination or damage. Especially use a magnifying lens to check the most concealed areas, the joints and the handles.If any contamination is detected, repeat the cleaning procedure.In case of damage, dispose of the instrument as established by the laws in force for waste management.

PRESERVATIONAfter the sterilisation phase, the instruments must be preserved in the sterilised package in a dry, dust-free place, far from heat sources. The bags must only be opened before use. The storage period of sterilised items must not exceed the period recommended and indicated on the bag.

DISPOSAL PROCEDURESAt the end of its life the medical device must be disposed of according to the methods established by national laws in force for waste management.

PREL

IMIN

ARY

IN

DIC

ATI

ON

S F

OR

INS

TRU

MEN

T U

SE

Warning The use of suitable protection during cleaning and sterilisation of contaminated instruments enhances personal safety during these phases.

Page 10: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

INSTRUMENTS WARNINGS AND LEGENDS

NON-ROTATING INSTRUMENTThe non-rotating instrument is compatible with all Dental Tech implant systems.

INS

TRU

MEN

TS W

ARN

ING

S A

ND

LEG

END

S

10

WARNINGSRESPONSABILITY The use of non-original components, produced by third-parties may compromise the functionality of the implants and their elements, compromising the final result and voiding the guarantee of the manufacturer. The application of the product occurs outside the control of Dental Tech and is the sole responsibility of the end user. We accept no liability for any damage resulting from such activities.INSTRUCTIONS FOR USE These are to be considered solely as recommendations. This information is not sufficient and does not exempt the user from ensuring the adequacy of the product for its intended use through continued training.VALIDITY This nullifies all previous versions. The images, the content and the products illustrated are subject to modification without warning.

Ti5

inox

Au

Polymer

MATERIALS LEGEND

Peek

Plastic

Pmma

PACKAGING SYMBOLS LEGEND

0123

Lot number

Sterilized by gamma rays

Not sterile

Product code

Reusable

Use by

Non-reusable

Attention, consult the supplied documentation

Directive 93/94/CEE conformity mark

Notified body identification

Titanium gr.V ELI for medical use

Surgical Stainless Steel

Gold Alloy

Polymethylmethacrylate

Polyetereeterechetone

BWS® are registered trademarks of DentalTech® S.r.l. Any reproduction or publication is permitted only with the written authorization of DentalTech® S.r.l.

Page 11: CPTP2020-0-webENG · H height mm ImpLassic FTP Implant Line Height (H) mm REF 003335 003336 003338 2 3,5 4,5 Height (H) mm REF 003350 003351 2 3,5 Height (H) mm REF BTA3710 BTA3725

BIBLIOGRAPHY and SALE CONDITIONS

BIBLIOGRAPHY

Abrahamsson I, Zitzmann NU, Berglundh T, WennerbergA, Lindhe J. Bone and soft tissue integration to titaniumimplants with different surface topography: an experimentalstudy in the dog. Int.J.Oral Maxillofac Implants 2001;16(3):323-32.

Abrahamsson I, Zitzmann NU, Berglundh T, Linder E.,Wennerberg A, Lindhe J. The mucosal attachment totitanium implants with different surface characteristics: anexperimental study in dogs. J Clin Periodontal 2002; 29(5):448-55.

The Role of Surface TopographyHerman, J Perio 1997;68:1117-1130.

Micro-threads eliminate bone lossdue to crestal disuseatrophy Hansson, Clin Oral Imp Res,1999.

Topografia della neoformazione ossea perimplantare: studiosperimentale G Petrone, G. Iezzi, M. Piattelli, A. Scarano Dipartimento di scienze Odontostomatologiche,Università “ G. D’Annunzio” Chieti- Pescara.

Surface Chemistry Effects of topographic Modificationof Titanium Dental Implant Surfaces:1. Surface AnalisisM. Morra, dr. chem / C. Cassinelli, dr. Biol / G.Bruzzone, MDA. Capri, MD / G. Di Santi, MD / R. Giardino, MD / M. Fini, MD.Int. JOMI 2003; 18:40-45

Surface Chemistry Effects of topographic Modificationof Titanium Dental Implant Surfaces:2. In Vitro ExperimentsM. Morra, dr. chem / C. Cassinelli, dr. Biol / G. Bruzzone, MDA. Capri, MD / G. Di Santi, MD / R. Giardino, MD / M. Fini, MD.Int. JOMI 2003; 18:46-52

Valutazione della precisione della connessione tra moncone ed impiantoBenedicenti S.* / Balboni C.** / Maspero F. * / Benedicenti A.*Quintessence International 3/4 bis 2001

Adesione cellulare epiteliale su superfici di titanio sabbiate e acidificate: studio in vitroI. Vozza / A. Scarano* / S. Rossi / M. QuarantaSupplemento n.1 a Doctor OS anno XIV n.1 gennaio 2003

Valutazione istologica della risposta ossea a una nuova superficie implantare sabbiata e mordenzata: uno studio sperimentale sul coniglio Antonio Scarano / Giovanna Iezzi* / Alessandro Quaranta** / Adriano Piattelli*Implantologia orale numero 2 marzo 2007

Dentista moderno ottobre 2011Progettazione e realizzazione di una superficie implataredalla decontaminazione all’osteointegrazioneChiara Giamberini / Angelo Tagliabue / Dino Azzalin/ Giorgio Santarelli

Int J Periodontics Restorative Dent. 2006 Feb; 26(1): 9-17Platform switching: a new concept in implant dentistry forcontrolling postrestorative crestal bone levels.Lazzara RJ / Porter SS.

IVela-Nebot X, et al.Benefits of an implant platform modification technique toreduce crestal bone resorption.Implant Dent 2006;15:313–320

SALE CONDITIONS

With the placing of an order, the present Conditions of Sale are considered to be accepted by the Customer.

The Company reserves the right to modify the Pricelist at any time, and without prior warning.

The goods travel at the risk of the Customer, even if delivered postage free.

Payment must occur according to the agreed terms and method. In the event of non-fulfilment, the Company reserves the right to vary the conditions of payment for the new supplier or to suspend them and to resort to any other precautionary and executive measures for a total recovery of the sum owed.

The delivery terms have an indicative value. The Company reserves the right to make partial deliveries.

Each claim for defect or damage must be communicated in writing within 8 days of receiving the goods. Any returns must be previously authorized by the Company.

For everything not expressly stated in the General Terms of Sale the provisions of Italian law shall apply. All disputes fall under the jurisdiction of the Court of Monza.

Via G. Di Vittorio, 10/12 20826 Misinto (MB), Italy

Tel. + 39 02 967.20.218Fax + 39 02 967.21.269

[email protected]