CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ......

12
CP PUMPEN Magnetkupplungspumpe metallisch sicher robust wirtschaftlich Magnetic drive Pump Metallic safe robust efficient MKP

Transcript of CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ......

Page 1: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

CP

PU

MP

EN

Magnetkupplungspumpe metallischsicherrobustwirtschaftlich

Magnetic drive Pump Metallicsaferobustefficient

MKP

Page 2: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

Herkömmliche Bauweise ohne HeizungConventional design without heating jacket

Herkömmliche Bauweise mit HeizungConventional design with heating jacket

Page 3: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

MKP Inline MKTP Tauchpumpe | Sump pump

MKP Vertikal | Vertical

MKP Monoblock | Close coupled

MKP Konsole | Console

MKP Lagerstuhl beheizt | Bearing frame jacketed

MKP Hochtemperatur | High-temperature

MKP-S Selbstansaugend | Self priming

Page 4: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

60

50

40

30

20

10

0

H[m

]

Q [m3/h]1 10 100

MKP 3000 min -1/50Hz

MKP 1500 min -1/50Hz

MKP-S 3000 min -1/50Hz

MKP 3600 min -1/60Hz

MKP 1800 min -1/60Hz

120

110

100

90

80

70

60

50

40

30

20

10

0

H[m

]

45

40

35

30

25

20

15

10

5

0

H[m

]

180

160

140

120

100

80

60

40

20

0

H[m

]

70

60

50

40

30

20

10

0

H[m

]

Q [m3/h]1 10 100 1000

Q [m3/h]1 10 100 1000

MKP-S 3600 min -1/60Hz

100

90

80

70

60

50

40

30

20

10

0

H[m

]

Q [m3/h]1 10 100

Q [m3/h]1 10 100 1000

Q [m3/h]1 10 100 1000

20-1

5-16

0

40-2

5-16

0

50-3

2-16

0

65-4

0-16

0

80-5

0-16

0

100-

65-1

60

20-1

5-20

0

40-2

5-20

0

50-3

2-20

0

65-4

0-20

0

80-5

0-20

0

100-

65-2

00

125-

80-2

00

50-3

2-25

0

65-4

0-25

0

80-5

0-25

0

20-1

5-16

0

40-2

5-16

0

50-3

2-16

0

65-4

0-16

0

80-5

0-16

0

100-

65-1

60

20-1

5-20

0

40-2

5-20

0

50-3

2-20

0

65-4

0-20

0

80-5

0-20

0

100-

65-2

00

125-

80-2

00

50-3

2-25

0

65-4

0-25

0

80-5

0-25

0

50-3

2-16

0

80-5

0-16

0

50-3

2-16

0

80-5

0-16

0

20-1

5-16

020

-15-

200

40-2

5-20

0

50-3

2-20

0

65-4

0-20

0

80-5

0-20

0

100-

65-2

00

125-

80-2

00

40-2

5-16

0

50-3

2-16

0

65-4

0-16

0

80-5

0-16

0

100-

65-1

60

50-3

2-25

0

65-4

0-25

0

80-5

0-25

0

150-

125-

315

200-

150-

315

150-

125-

315

200-

150-

315

20-1

5-16

0

40-2

5-16

0

50-3

2-16

0

65-4

0-16

0

20-1

5-20

0

40-2

5-20

0

50-3

2-20

0

65-4

0-20

0

80-5

0-20

080

-50-

160

100-

65-1

6010

0-65

-200

125-

80-2

00

50-3

2-25

0

65-4

0-25

0

80-5

0-25

0

Page 5: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

CP Pumpen MKP ohne Heizung

CP Pumpen MKP without heating jacket

1Im Gegensatz zur herkömmlichen Bauweise zentrale Lageranordnung = keinGleitlagerträger erforderlich,hervorragende Laufeigenschaften auch bei Feststoffen oder Leichtsiedern

Contrary to the conventional design - central bearing location = no plain bearingbracket is required, excellent performance even with slurry or solvents

2Gegenüber der herkömmlichen Bauweiseausgezeichnete Spül- und Kühleigenschaftender Lagerung = hohe Betriebssicherheit

Contrary to the conventional design -excellent flush and cooling characteristic ofthe bearing = increased reliability

3Im Gegensatz zur herkömmlichen Bauweisesehr kompakte Bauform, keine Toträume

Contrary to the conventional design - unique compact design, dead-space free

4Gegenüber der herkömmlichen Bauweise wenig Einzelteile = einfach undmontagefreundlich

Contrary to the conventional design - very few parts = simple and easy to assem-ble and maintain

CP Pumpen MKP mit Heizung

CP Pumpen MKP with heating jacket

5Gegenüber der herkömmlichen BauweiseBeheizung der gesamten Pumpe mittelseines einzigen Heizmantels = niedrigeInstallationskosten

Contrary to the conventional design – single piece heating chamber fully encases the complete pump hydraulics = low installation cost

6Im Gegensatz zur herkömmlichen Bau-weise sehr gute Wärmeverteilung in derPumpe = keine Gefahr von kalten Zonen

Contrary to the conventional design - veryefficient heat distribution within the pump = no risk of cold zones

7Im Gegensatz zur herkömmlichen Bau-weise hohe Wärmeübergangseffizienz,Heizenergie leitet direkt in den Flüssigkeits-raum = kurze Aufheizzeiten

Contrary to the conventional design - highefficient heat transfer. Heat is conducted direct into the pumpliquid = short heat-time

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3

2

1

4

66

5

7

Page 6: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy
Page 7: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

Pump conceptTo satisfy today’s requirements of thechemical industry, chemical processpumps must include the followingfeatures:compact design fewer, simple partseasy maintenanceminimising of hydraulic forces within the pumpdefined flushing capabilityutilisation of standard drivers

Design FeaturesThe CP Pumpen Model MKP incorpo-rates all the above requirements.Together with an extensive range ofoptions it makes an ideal selection forall services where any leakage (corro-sive and dangerous liquids) must beavoided.

BearingsThe compact design combines fewand simple parts. The impeller rota-tes on a static sleeve securely fixedby the locking sleeve. This unique design ensures theimpeller rotates in a hydraulically ba-lanced and stable condition with theaxial thrust compensated by hydrau-lic balance holes in the impeller andthrust runners to compensate atupset conditions, start-up and duringprocess.

Magnetic Coupling - seallessSince the shaft has no connection tothe impeller, all problems associatedwith shaft sealing are eliminated.Drive torque is transmitted throughhigh quality samarium cobalt mag-nets. The pumped fluid is hermetically sea-led by a Hastelloy C-4 or an Eddy-cur-rent free high performance polyme-ric containment shroud. The external flush to the internalpump bearing, together with thematerials selected for this bearingmakes the handling of slurries possi-ble.

Technical Data Construct. according to EN 22858Temp. range: -100˚up to 350˚CCapacity Q up to 600 m3/hHead H up to 110 mPress. rating PN 16/25 barSolids 0.5 mm up to 30%Materials: Stainless steel, Alloy 20,Hastelloy B + C, Monel, Titanium

Construct. according to ANSI B73.1Temp. range: -150˚up to 660˚FCapacity Q up to 420 gpmHead H up to 310 ftPress. rating PN 16/25 barMaterials: Stainless steel, Alloy 20,Hastelloy B + C, Monel, Titanium

----

--

PumpenkonzeptUm die heutigen Anforderungen derchemischen Industrie zu erfüllen,muss eine Chemieprozesspumpe fol-gende Vorteile aufweisen:kompakte BauweiseAufbau aus wenigen, einfachen Einzelteileneinfache Montage- und Demontagemöglichkeitenkeine grossen hydraulischen Kräfteim Pumpeninnerninterne und externe Schmier-möglichkeitenAntriebsmöglichkeiten durch Norm-motoren

KonstruktionsmerkmaleDas CP Pumpen Modell MKP erfülltdiese Spezifikationen und bietet we-sentliche Konstruktions- und Materi-alvorteile. Dies sind die besten Vor-aussetzungen, um korrosive und ge-fährliche Medien zu fördern, an Stel-len wo keine Leckage erlaubt ist.

LagerungDie kompakte Bauweise des Laufra-des ergibt im Betrieb eine Kreiselwir-kung: Es dreht stabil um seine grössteTrägheitsachse. Das Pumpeninnereist durch wenige, robuste Einzelteilegekennzeichnet. Ein einziges Radial-lager dient als Führung und zur Auf-nahme der hydraulischen Kräfte.

Magnetkupplung - DichtungslosDas Fehlen der Wellendurchführunglöst Abdichtungsprobleme - keine Le-ckage. Die Kraftübertragung erfolgtüber eine Samarium-Kobalt-Perma-nent-Magnetkupplung. Das Pumpen-innere wird mit einem Spalttopf ausHastelloy C-4 oder WirbelstromfreienHochleistungskunststoff hermetischabgeschlossen. Genau definierte Schmiermöglich-keiten des Lagers sowie dessen Mate-rialwahl ermöglichen die Förderungfeststoffbeladener Flüssigkeiten.

Technische Daten Konstruktion nach EN 22858Temperaturbereich -100˚bis 350˚CVolumenstrom Q bis 600 m3/hFörderhöhe H bis 110 mNenndruck PN 16/25 barFeststoffe 0.5 mm bis 30%Werkstoffe: Edelstahl, Uranus,Hastelloy B + C, Monel, Titan

Konstruktion nach ANSI B73.1Temperaturbereich -150˚bis 660˚FVolumenstrom Q bis 420 gpmFörderhöhe H bis 310 ftNenndruck PN 16/25 barWerkstoffe: Edelstahl, Uranus,Hastelloy B + C, Monel, Titan

--

-

-

-

-

Page 8: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy
Page 9: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

1

6

2

7 8

3

Dichtungslose Chemieprozesspumpe MKPSealless chemical process pump MKP

Page 10: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

OptionenPumpengehäuse mit Heizmantel,Heizung mit GewindeanschlüssenPumpengehäuse mit Heizmantel,Heizung mit FlanschanschlüssenGehäuse mit Entleerungs-flanschanschlussThermoelement am SpalttopfSpalttopf mit WirbelbrecherWirbelstromfreier SpalttopfMessumformer/Klemmenplattefür ThermoelementGehäuse –VerschleissringSSIC (Siliziumkarbid) GleitlagerSSIC-Graphit GleitlagerWOC (Wolframkarbid) GleitlagerDiamantbeschichtung (ADLC)FuturaSafe® LagerungKühleinsatz LagerstuhlStellfüsse für Grundplatte

Gehäuse gebohrt nach ANSI 150 # R.F./300 # R.F.PT 100 TemperatursondeMotorbelastungswächterExterner Spülanschluss im Magnetbereich und/oder der GleitlagerDoppelspalttopf für Vakuum-überwachung

1

2

3

4567

89

1011

-

---

-

OptionsFully jacketed casing and magneticarea with threaded connectionFully jacketed casing and magneticarea with flanged connectionCasing with flanged drainShroud temperature monitoringwithwithout transmitterShroud with vortex breakerEddy-current free shroudTransmitter/Connector pad forthermoelectric elementCasing wear ringSSIC (Silicon carbide) bearingSSIC-Graphite bearingTC (Tungsten carbide) bearingDiamond coating (ADLC)FuturaSafe® bearingBearing frame coolerBaseplate stilts

Casing drilled according toANSI 150 # R.F./300 # R.F.PT 100 temperature sensorMotor load monitoringExternal flush connections on ma-gnetic and/or on the bearing areaDouble shroud for vacuum monitoring

1

2

34

567

89

1011

-

---

-

4

11109

5 11

Page 11: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

ALagerstuhlausführungBearing frame execution

BBeheizte AusführungPump with heating jacket

1PumpengehäusePump casing

2LaufradImpeller

3Innenliegender MagnetrotorInboard magnet rotor (driven)

4Aussenliegender MagnetrotorOutboard magnet rotor (driving)

5Interne Lagerschmierung oderexterner SpülanschlussInternal bearing flushing or external flushing connection

6Laufradbefestigung mittels einereinzigen SpannhülseImpeller connection with onlyone locking sleeve

7SSIC Lagerung (Standard)SSIC bearing (standard)WOC-WolframkarbidTC-TungstencarbideFuturaSafe®

8Spalttopf-hermetisch dichtShroud-sealless

9Spalttopf-Temperatur-überwachungShroud-temperature monitoring

1

2

76

5

AB

3

4

8

9

1

2

4

5

7

6

8

9

Page 12: CP PUMPEN · PDF file125-80-200 50-32-250 65-40-250 80-50-250. CP Pumpen MKP ohne Heizung ... pumps must include the following features: compact design fewer, simple parts easy

Han

ns

Sch

mid

Gra

fikD

esig

nB

aden

ww

w.s

chm

idg

rafi

kdes

ign

.ch

CP

_02

D|E

05|1

0

CP Pumpen AGIm Brühl4800 ZofingenSwitzerland

Tel. +41 (0)62 746 85 85Fax +41 (0)62 746 85 [email protected]

CP Pumpen GmbHPfälzer Ring 8-1068766 HockenheimGermany

Tel. +49 (0)62 05 20 41 0Fax +49 (0)62 05 20 41 [email protected]