Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea...

26
Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311 China Tel: +86-757-26338535 Fax: +86-757-26338232 E-mail: [email protected] Http: //www.midea.com.cn Http: //www.mideaaircon.com (customer service) Midea Air-con (Malaysia) Sdn Bhd Add: Unit 7.01A, 7th Floor, MCB Plaza, 6 Cangkat Raja Chulan, 50200 Kuala Lumpur Tel: +603-27113012 +603-17113013 Fax: +603-27113010 E-mail: [email protected] Http: //www.mideaaircon.com (customer service) Midea Air-con Middle East FZE Add: Jumeirah 3, Street 22, Villa no 22(7), Dubai, U.A.E. Tel: +971-50-3985932 Fax: +971-4-3940859 E-mail: [email protected] Http: //www.mideaaircon.com (customer service) Midea Electric (HK) Ltd. (A Subsidiary of Global Operation Group) Add: 39/F., Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852-23761229 Fax: +852-23761297, +852-23176837 Technical Services Centre Tel: +852-21746728 Fax: +852-21727876 Contact: Mr. Sandy SU E-Mail: [email protected] Midea Air-conditioning Europe Corp Add: Zuelpicher Str. 5, D-40549 Duesseldorf, Germany Tel: +49-211-5637713 Fax: +49-211-5637889 E-mail: [email protected] Http: //www.mideaaircon.de (customer service) Midea Air-conditioning America Corp Add: 10305 N.W.41st Street, Suite 221 Miami, Florida 33178 Tel: +1-305-591-8460 Fax: +1-305-591-8451 E-mail: [email protected] Http: //www.mideaservice.com (customer service)

Transcript of Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea...

Page 1: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Midea Is Your Idea

50Hz2007

GD Midea Air-conditioning Equipment Co., Ltd.

Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311 China

Tel: +86-757-26338535 Fax: +86-757-26338232

E-mail: [email protected]

Http: //www.midea.com.cn

Http: //www.mideaaircon.com (customer service)

Midea Air-con (Malaysia) Sdn Bhd

Add: Unit 7.01A, 7th Floor, MCB Plaza, 6 Cangkat Raja Chulan, 50200 Kuala Lumpur

Tel: +603-27113012 +603-17113013 Fax: +603-27113010

E-mail: [email protected]

Http: //www.mideaaircon.com (customer service)

Midea Air-con Middle East FZE

Add: Jumeirah 3, Street 22, Villa no 22(7), Dubai, U.A.E.

Tel: +971-50-3985932 Fax: +971-4-3940859

E-mail: [email protected]

Http: //www.mideaaircon.com (customer service)

Midea Electric (HK) Ltd. (A Subsidiary of Global Operation Group)

Add: 39/F., Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong

Tel: +852-23761229 Fax: +852-23761297, +852-23176837

Technical Services Centre Tel: +852-21746728 Fax: +852-21727876

Contact: Mr. Sandy SU E-Mail: [email protected]

Midea Air-conditioning Europe Corp

Add: Zuelpicher Str. 5, D-40549 Duesseldorf, Germany

Tel: +49-211-5637713 Fax: +49-211-5637889

E-mail: [email protected]

Http: //www.mideaaircon.de (customer service)

Midea Air-conditioning America Corp

Add: 10305 N.W.41st Street, Suite 221 Miami, Florida 33178

Tel: +1-305-591-8460 Fax: +1-305-591-8451

E-mail: [email protected]

Http: //www.mideaservice.com (customer service)

Page 2: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

1 2

N433

E U R O V E N TCERTIFIED PERFORMANCE

TUV Rheiniand Group Production inspected

L I S T E D

TUV Rheiniand

gepruftesicherheit

NRTL/CISO 14001: 1996

Certificate No.:CC1417

068

CERTIFIEDCOMPANYCERTIFIED

COMPANY

ISO 9001 : 2000Certificate No.: CC 454

068

I N TERN AT IONAL CONFORMI TY C ERT I F ICAT I

ONPR

OGRA

MSAUDI ARABIAN STANDARDS ORGANIZATI O

N

Midea produced its first Air

Conditioner in 1985. Currently

we are the leader of Air

conditioner manufacturing

and export. Midea has been

exporting Air Conditioners for

the last 16 years, and during

this time Midea has cultivated

strong partnerships with

hundreds of overseas

companies.

Midea is dedicated to

continuous improvement. Over

1000 engineers work together

to push the improvement of

AC technology. Every year

over 300 new products are

developed and 100 new

patents are filed. New products

account for 30% of total sales

volume and 35% of gross

profit.

Our vertically integrated

supply chain enables us to

achieve maximum efficiency

in production and product

development.

We p rov ide G loba l

technical training and a

comprehensive online

customer service. All our

customers from over 110

countries and regions

receive top quality service

at all times.

Our goal is to deliver the

highest quality products to

our costumers. Quality is one

of the core competencies of

Midea.

Midea Creates A Better Life

geprufteSicherheit

..

Page 3: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Fresco Tech

The photo is zoomed 3000 times.

Dust electroded

Particles High electric voltage field

Odor Generating plasma

Fresh AirPollutedAir

Electronegative filter

+5KV discharge

Bio Filter consists of a specialized biological enzyme and Eco filter.The Eco filter catches very small airborne dust particles and neurilities bacteria, fungi and microbes.

Bio Filter (Optional)

Biological enzyme eliminates bacteria by dissolving their cell wall thus eliminating the problem of re-pollution seen in traditional air conditioners.

Active Carbon Electrostatic Fiber Filter is made of Active Carbon andElectrostatic Fiber Filter.Active Carbon Filter eliminates certain kinds of odors such as ammonia (NH3) and deactivates harmful chemical gas such as formaldehyde(HCHO).By forming positive positions on the filter surface, Electrostatic Fiber Filter traps small dust particles, smoke and pet fur to prevent allergic reactions.

Active Carbon Electrostatic Fibre Filter (Standard)

Sterilization mechanism of Bio Filter4.Germ Dies1.Germ & Enzyme 2.Cell Wall Dissolved 3.Cell Membrane Burst

Cell

Enzyme

CombineWall

EnzymeDead Cell

Silver Ion Filter (Optional)

The Silver ion can kill bacteria or prevent their activity at very low density by destroying their inner-configuration and absorbing their elements in cells. Meanwhile, the Nano Silver attached on the filter release the Silver ion constantly to eliminate bacteria effectively and continuously.

Anions can take care of your bodyAnions can stimulate the blood circulation system, improve lung function and effectively prevent respiratory passage illnesses (Such as asthma and pneumonia).

Anions Eliminate Dust and Smoke:When air passes through the ionizer brush, Anions are automatically generated by ionization (3400V high static field). The amount of anions can reach as high as 1,000,000/cm3. The anions deactivate the airborne chemical vapors and dust particles.

Ionizer (Optional)

Progress of " Vitamin-C emission" every 6 hours

6hours 12hours 18hours 24hours0.0

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L)

Performance of the emission in case of Continuous running

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L) 0.70

0.65

0.60

0.55

0.50

0.45

0.30

0.30

0.35

1 day 2 days 3 days 4 days 5 days 6 days

NH3 Removal Ratio of Active Carbon Filter

Time(min)

Density of NH3

(mg/m3)NH3 Removal Ratio

(mg/m3)

0

30

60

120

3.17

0.51

0.28

0.22

*

83.91

91.17

93.06

3 4

Silver Ion

VC

VC

VC

VC

VC

VC

VC

VC

VC

VC

DustBacteria

Bio Filter

DustMicrobesFungi

Active Carbon & Dust Filter

HCHO DustNH3

Plasma Dust Collector

Smoke Pollen Dust

Deodorization

Natural

Plasma

100

80

60

40

20

0

(%)

15 30 45 60(Min)

Dust Reduction

Natural

Plasma

100

80

60

40

20

0

(%)

10 20 30(Min)

Dust Removal Ratio of Electrostatic Fibre Filter

7

6

5

4

3

2

1

0

Density(m

g/m

3)

Time(min)0 10 20 30 40 50 60 70 80 90 100

Midea's Fresco Tech brings you clean and refreshing air and fills your room with the soothing scent of nature.

The Vitamin C filter fills the air with vitamin C, which softens the skin and reduces stress. The lifetime of the Vitamin C filter is approximately two years.

Vitamin C Filter (Optional)

The Plasma Dust Collector can generate an ionization zone. The air is converted to plasma as it passes the high voltage ion generator. 95% of the dust, smoke, and pollen particles are attracted to the electrostatic filter.

Plasma Dust collector (Optional)

Vitamin C Filter

VC Vitamin C

Ionizer

AnionsBacteria Dust

Page 4: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Water Air Salt

Aluminum

Golden Coating Layer

5 6

50

150

200

300

%

Amou

nt o

f ger

m

100

250

350

400

Normal evaparatorGolden Bio evaparator

0

Changes Of Germ Amount After 24h Test

6 12 18 24Time

It can efficiently prevent bacteria from breeding and spreading. It helps create a health and comfortable environment.

Golden Bio Evaporator

Midea's Tele Remote Control Technology enables you to control

your A/C at anytime and anywhere by telephone.

Automatic tone instruction makes it simple for the A/C setting

such as the mode setting, temperature setting and fan speed

setting.

Password setting ensures a safe operation.

Tele Remote Tech

The Golden hydrophilic condenser can improve the heating efficiency by accelerating the defrosting process. The unique anti-corrosive golden coating on the condenser can withstand the salty air, rain and other corrosive elements.

Golden Anti-corrosive Condenser

Corrosion test results

Golden Tech

235

6890

#

7*

FeaturesEasy-cleaned PanelThe front panel may be easily removed for periodic cleaning.

Flexible Wiring ConnectionTerminal block makes the cable connecting between indoor and outdoor unit much more flexible.

Anti-Rust CabinetMade from electrolytic zinc steel sheet and anti-rust coated components.

Soft-starter KitIt can keep the starting current within the limit of 45 A, which is suitable for some countries such as Australia, and North European countries.

Conventional condenser

Golden condenser

Turbo ModeThis function enables the unit to reach the preset temperature in the shortest time.

Auto-Restart Function when the power is off and then on, The unit automatically restores the previous function setting.

Low Ambient KitThe unit can operate in cooling mode at low ambient temperature conditions.

Oxygen generating mechanismT h e o x y g e n e n r i c h m e n t membrane in the outdoor unit can increase the oxygen density.

Valve Protection Cover It protects the valves and prevents water from dripping.

Two-direction Air Vane TechnologyIn cooling mode, the air vane opens counterclockwise, which directs the air horizontally. It allows for rapid and evenly distributed temperature fall.In heating mode, the air vane opens clockwise, which directs the air toward the floor. It allows for rapid and evenly distributed temperature rise.

Anti-Cold Air Function (Heat Pump Only)When the evaporator temperature is warm enough, the fan begins to operate, preventing any cold blasting.

Multi-Bend Heat ExchangerCompared with conveCompared with conventional models, Midea's airconditioners adopt multi-bend heat exchangers. It help increase the heat-exchange surface so that it improves efficiency.

Self-diagnosis and Auto-protection FunctionThis function can electronically detect the errors and display the diagnosis by a series of flashing LEDs on the indoor unit. Then the unit will automatically switch to protection mode.

Low Noise Air Flow SystemLarge Diameter Cross Flow FanWithout decreasing the flow volume, large diameter cross flow fan can greatly reduce the indoor unit's noise level by lowering the fan speed.

Temp. Compensation (Optional)The ceiling temperature is often higher than the floor temperature. This function can automatically el iminate the temperature difference between them.

Two-speed outdoor fan(applicable to models>24000Btu/h)With 2-speed fan motor, the outdoor unit can operate powerfully at high speed or can be adjusted to quiet and low speed operation at night.

Independent DehumidificationThe unit will alternately operate in cooling mode or fan only mode, w h i c h a s s u r e s s t r o n g dehumidif ication while not lowering room temperature.

Hydrophilic Aluminum FinIn the indoor unit, it improves the cooling efficiency by enabling the unrestricted flow of condensate between the heat exchange fins In the outdoor unit, it improves the heat ing eff ic iency by accelerating the defrosting process.

Fresh AirMidea air conditioner have a pump in the indoor unit, when press the "Fresh Air" button, the pump suck the fresh air from outside, and the indoor polluted air flow out of the room via the air pressure.

Trapeziform Innergroove CopperCompared with the triangular innergroove copper, it allows more adequate refrigerant to go through, improving heat exchange efficiency and lowers power consumption.

Sleep ModeThis function enables the unit to automatically increase (cooling) or decrease (heating) 1oc per hour for the first two hours, then hold steady for the next 5 hours, after that the unit will stop operation. I t can maintain the most comfortable temperature and save energy.

Page 5: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

7 8

HOW TO READ THE MODELS ?

Factory Design Code

Control ModeE Electric ControlR Remote Control

M Mechanical Control

M S H I - 12 H R D N1 - Q D2 F

E Elite

H Alfa

J Dorado

Product SeriesResidentialG Glory

V1 Vertu

V3 Aqua

Midea

Connection TypeI Multi Type

- Single Type

CapacityAir Conditioner: Cooling/Heating Capacity (x1000Btu/h)Dehumidifier : Moisture Removal Volume (L/day)

Function CodeC Cooling Only

H Cooling & Heating

A Cooling & Heating with Auxiliary Electric Heater

E Cooling & Electric Heater

RefrigerantN2 R407C

N3 R134a - R22

Inverter TypeI AC Inverter D DC Inverter- Constant Speed

Fan Speed AdjustmentHIGH / MED / LOW / AUTO

Air Flow Direction Setting

Temperature Setting

(Time Adjustment)

Timer SettingTIMER / CANCEL

Clock Setting

LED Display

Sleep Mode

Turbo

Sliding Cover

On/Off Button

Mode SettingCOOL / HEAT / DRY / FAN / AUTO

Automatic Swing

Lock Pinhole Button

Reset Pinhole Button

Power CodeQRS

Power Supply(V-Hz-Ph)220-240V~, 50Hz, 1Phase

380-420V~, 50Hz, 3Phase

380V~, 50Hz, 3Phase

Applicable to most of Midea's models.

Button design might be slightly different from the actual one depending on individual models.

Unit TypeResidentialS Split Wall-mounted

W Window

P Portable

D Dehumidifier

F Floor-standing

O Outdoor unit

Page 6: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

9 10

Vertu

Alfa P lus

F loor-s tanding

F Window

M1 P ortable

K1 P ortable

K P ortable

F P ortable

Mini P ortable

F Dehumidifier

Dehumidifier

Glory S tar Fami ly

Dorado

E l i te 1713

1541

4619

2127

-31

3339

4243

4445

47

V F loor-s tanding1 8000-28000B tu/h

J F loor-s tanding1 8000-48000B tu/h

S 2 F loor-s tanding24000-48000B tu/h

E F loor-s tanding60000B tu/h

Vita

Hel i t

Aqua

2325

AC I nverter

AC I nverter Mul ti

9'000 12'000 18'000 21'000 24'000 28'0007'000

Multi

S ingle

Page 7: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Midea Air Conditioners

Split

Wall-mounted Type

Midea Is Your Idea

Page 8: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Vertu

13 14

Self-CleaningThis function can be selected by remote controller.

When the "CLEAN" button is pressed, the indoor unit

will automatically clean the evaporator. This function

can restrict the breeding of bacteria in the unit and

keep the air fresh.

Specification:

Low Cool operation Low Heat operation Fan only operation

IonizerThe abundance of anions

present at waterfall, rivulet

and in forest soothes and

refreshes people. Midea air

conditioners have taken

advantage o f Ion izer

Technology to bring the

refreshing air to your home.

MSV1-07CR-QB8F

MSV1-07HR-QB8F

MSV1-09CR-QB8F

MSV1-09HR-QB8F

MSV1-12CR-QB8F

MSV1-12HR-QB8F

MSV1-18CR-QB8F

MSV1-18HR-QB8F

MSV1-21CR-QB6F

MSV1-21HR-QB6F

Cooling Only Cooling & Heating

MSV1-07/09C(H)R-QB8F

MSV1-12C(H)R-QB8F

MSV1-18/21C(H)R-QB6F

Features:Follow Me

Standard Optional

Follow meWith this technology, a temperature sensor is built

in the remote controller. When you stay close to

the remote controller, the unit will automatically

change the operation mode to supply more

comfortable temperature just like the air conditioner

is following you.

Available Colours:

Black(Black Mirror)

Silver Gray(HJ-816)

Dark Red(HJ-826)

Dark Blue(HJ-823)

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

220-240V~,50Hz

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

70002.1

9.8, 2.86

45036/33/30

51

220-240, 50, 17303.2

850x340x285815x580x325

12.5/26

10-14

120/258/292

795x270x165700x535x235

10/24

6.35 (1/4") 9.53 (3/8")

7000/80002.1/2.3

730/7403.2/3.3

10/25

12.5/27

90002.6

9.6, 2.82

55038/55/32

53

9204.2

14-21

9000/100002.6/2.9

3.12

920/9304.2/4.2

10/26

12.5/28

IMSV1-07CR-QB8F IMSV1-07HR-QB8F IMSV1-09CR-QB8F IMSV1-09HR-QB8F

3.09

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

120003.5

9.6, 2.82

65042/39/36

55

220-240, 50, 112405.6

905x355x285910x575x335

13.5/37

18-16

108/220/258

845x286x165780x540x250

10.5/34

6.35 (1/4") 12.7 (1/2")

12000/130003.5/3.8

1240/12105.6/5.5

10.5/35

13.5/38

180005.3

92044/42/39

56

18808.6

950x292x197

16/37

30-40

18000/190005.3/5.6

3.13

1880/18008.6/8.2

16/38

19/41

210006.1

231010.7

970x770x39519/57

66/142/163

845x690x33516/53

21000/230006.1/6.7

2.88

2310/232010.7/10.8

16/55

19/59

94/199/228

IMSV1-12CR-QB8F IMSV1-12HR-QB8F IMSV1-18CR-QB8F IMSV1-18HR-QB8F IMSV1-21CR-QB6F IMSV1-21HR-QB6F

1045x366x310

19/40

9.0, 2.64

102045/43/39

56

34-49

3.11

Page 9: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Cooling Only Cooling & Heating

A Ifa Plus

15 16

Dust electroded

Particles High electric voltage field

Odor Generating plasma

Fresh AirPollutedAir

Electronegative filter

+5KV discharge

MSH-07CR

MSH-07HR

MSH-09CR

MSH-09HR

MSH-12CR

MSH-12HR

MSH-24CR-QB6

MSH-24HR-QB6

MSH-28CR-QB6

MSH-28HR-QB6

MSH-18CR

MSH-18HR

MSH-21CR

MSH-21HR

Vitamin C Filter (Optional)

Vitamin C is one of necessary material for human

being, and it is also good for human skin. Vitamin C

Filter is made of Vitamin C Emission material. When

the air flows through it, the Vitamin C will be taken

everywhere in the room.

Progress of " Vitamin-C emission" every 6 hours

6hours 12hours 18hours 24hours0.0

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L)

Performance of the emission in case of Continuous running

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L) 0.70

0.65

0.60

0.55

0.50

0.45

0.30

0.30

0.35

1 day 2 days 3 days 4 days 5 days 6 days

Standard Optional

MSH-07/09/C(H)R

MSH-12C(H)R

MSH-18/21C(H)R

MSH-24/28C(H)R-QB6

Features:Outdoor Fan

Two-speed

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

The Plasma Dust Collector can generate an ionization

zone. The air is converted to plasma as it passes the

high voltage ion generator. 95% of the dust, smoke,

and pollen particles are attracted to the electrostatic

filter.

Plasma Tech (optional)

220-240V~,50Hz

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMSH-07CR IMSH-07HR IMSH-09CR IMSH-09HR IMSH-12CR IMSH-12HR IMSH-18CR IMSH-18HR

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

70002.1

9.6, 2.82

45034/32/29

51

220-240, 50, 17403.3

830x336x285815x580x325

10/26

10-14

125/268/295

750x250x205700x535x235

8/24

6.35 (1/4") 9.53 (3/8")

7000/80002.1/2.3

740/7603.3/3.4

8/25

10/27

90002.6

9.5, 2.78

50036/33/31

52

9354.2

10/26

14-21

9000/100002.6/2.9

2.99

935/9704.2/4.3

8/26

10/28

120003.5

12905.8

18-26

12000/130003.5/3.8

3.0

1290/12705.8/5.8

10/37

12/40

9.2, 2.71

60037/31/29

52

815x285x215780x540x250

10/36

915x360x290910x575x335

12x39

12.7 (1/2")

105/224/260

180005.3

19408.9

920x292x225

13.5x37

1015x370x295

15.5/40

18000/200005.3/5.8

2.9

1940/20008.9/9.1

13.5/38

15.5/41

9.3, 2.74

85041/38/35

54

30-40

98/207/246

3.0

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

210006.1

9.2, 2.70

95042/39/36

54

220-240, 50, 1226010.4

1015x370x295970x770x395

15.5/56

34-49

72/145/170

920x292x225845x695x335

13.5/52

6.35 (1/4") 12.7 (1/2")

21000/240006.1/7.0

2260/240010.4/11.1

13.5/53

15.5/57

240007.0

9.1, 2.68

108044/41/38

54

260012.0

1080x330x232

17/56

40-56

24000/270007.0/8.0

2.82

2600/284012.0/13.1

17/60

21/64

280008.0

305014.1

21/70

50-68

17/66

28000/300008.0/9.0

2.82

3050/320014.1/14.8

17/67

21/71

62/128/150

IMSH-21CR IMSH-21HR IMSH-24CR-QB6 IMSH-24HR-QB6 IMSH-28CR-QB6 IMSH-28HR-QB6

1165x445x320

21/60

8.6, 2.64

115046/43/40

55

9.53 (3/8") 16.0 (5/8")

2.91

Specification:

Page 10: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

220-240V~,50Hz

Oxygen generator (Optional)

The oxygen enrichment

membrane in the

ou tdoo r un i t can

increase the oxygen

density up to 30%. It

brings the refreshing air

to your home.

Oxygen-Rich Air

OxygenApprox

30%30%

Dust, pollen, bacteria,

etc., are eliminated

Oxygen enrichment membrane(silicon, 0.1um)

Breakup

Dispersal

Emergence

21%21%Approx

Oxygen

17 18

E lite

Dust electroded

Particles High electric voltage field

Odor Generating plasma

Fresh AirPollutedAir

Electronegative filter

+5KV discharge

Cooling Only Cooling & Heating

MSE-07CR

MSE-07HR

MSE-09CR

MSE-09HR

MSE-12CR

MSE-12HR

MSE-24CR

MSE-24HR

MSE-28CR

MSE-28HR

MSE-18CR

MSE-18HR

MSE-21CR

MSE-21HR

MSE-05CR

MSE-05/07/09/C(H)R

MSE-12C(H)R

MSE-18/21C(H)R

MSE-24/28C(H)R

Features:

Standard Optional

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

Ionizer (Optional)

The abundance of anions

present at waterfall, rivulet

and in forest soothes and

refreshes people. Midea air

conditioners have taken

advantage o f Ion izer

Technology to bring the

refreshing air to your home.

The Plasma Dust Collector can generate an ionization

zone. The air is converted to plasma as it passes the

high voltage ion generator. 95% of the dust, smoke,

and pollen particles are attracted to the electrostatic

filter.

Plasma Tech (optional)

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMSE-05CR IMSE-07CR IMSE-07HR IMSE-09CR IMSE-09HR IMSE-12CR IMSE-12HR

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

50001.5

8.9, 2.61

35033/29/26

47

220-240, 50, 15602.56

800x340x270815x580x325

9.5/26

8-12

126/272/298

710x250x195700x535x235

8/23

6.35 (1/4") 9.53 (3/8")

7000/80002.1/2.3

760/7803.5/3.6

8/26

9.5/28

90002.6

9.0, 2.64

45036/33/31

49

10004.6

8/26.5

9.5/29

14-21

9000/100002.6/2.9

2.99

1000/9804.6/4.4

8.5/28.5

9.5/31

120003.5

13005.9

18-26

12000/130003.5/3.8

3.0

1300/12705.9/5.8

11/37

9.2, 2.71

58037/35/33

52

790x265x195780x540x250

9/34

875x375x285910x575x335

11/37

12.7 (1/2")

108/226/266

70002.1

9.2, 2.69

40034/34/29

48

7603.5

10-14

6.35 (1/4") 9.53 (3/8")

8/25.5

9.5x27.5

3.0

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMSE-18CR IMSE-18HR IMSE-21CR IMSE-21HR IMSE-24CR IMSE-24HR IMSE-28CR IMSE-28HR

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

180005.3

9.0, 2.64

80041/39/37

54

220-240, 50, 120009.1

1015x370x295910x575x335

15/40

30-40

100/210/245

920x292x225780x540x250

13/37

6.35 (1/4") 12.7 (1/2")

210006.1

228010.3

21000/250006.1/7.3

2280/252010.3/11.5

17/55

21/59

240007.0

267012.1

1080x330x225

17/56

1165x445x320

21/60

24000/270007.0/8.0

2670/282012.1/12.8

280008.0

325014.8

17/66

21/70

18000/200005.3/5.9

2000/20209.1/9.2

13.5/40

16.5/42.5

9.2, 2.70

44/41/3854

970x770x39521/57

845x695x33517/53

9.53 (3/8") 16.0 (5/8")

34-49

66/142/163

2.919.0, 2.63

1080

40-56

2.81

17/60

21/64

8.6, 2.53

115046/43/40

55

50-68

28000/300008.0/9.0

3250/336014.8/15.2

17/67

21/71

2.62

60/132/142

2.90

Specification:

Page 11: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

220-240V~,50Hz

19 20

Bio Filter (Optional)

Bio Filter consists of a specialized biological enzyme

and Eco filter. The Eco filter catches very small

airborne dust particles and neurilities bacteria, fungi

and microbes.

Dorado

4.Germ Dies

EnzymeDead Cell

3.Cell Membrane Burst

1.Germ & Enzyme

Cell

Enzyme

CombineWall

2.Cell Wall Dissolved

Cooling Only Cooling & Heating

MSJ-07/09C(H)R-QB6

MSJ-12C(H)R-QB6

MSJ-18/21C(H)R-QB6

Features:

Standard Optional

MSJ-07CR-QB6

MSJ-07HR-QB6

MSJ-09CR-QB6

MSJ-09HR-QB6

MSJ-12CR-QB6

MSJ-12HR-QB6

MSJ-18CR-QB6

MSJ-18HR-QB6

MSJ-21CR-QB5

MSJ-21HR-QB5

Vitamin C Filter (Optional)

Vitamin C is one of necessary material for human

being, and it is also good for human skin. Vitamin C

Filter is made of Vitamin C Emission material. When

the air flows through it, the Vitamin C will be taken

everywhere in the room.

Progress of " Vitamin-C emission" every 6 hours

6hours 12hours 18hours 24hours0.0

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L)

Performance of the emission in case of Continuous running

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L) 0.70

0.65

0.60

0.55

0.50

0.45

0.30

0.30

0.35

1 day 2 days 3 days 4 days 5 days 6 days

Silver Ion Filter (Optional)

The Silver ion can kill bacteria or prevent their activity

at very low density by destroying their inner-

configuration and adsorbing their element in cells.

Meanwhile, the Nano Silver attached on the filter

release the Silver ion constantly to eliminate bacteria

effectively and continuously.Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

70002.1

9.1, 2.68

50034/31/29

50

220-240, 50, 17803.5

840x340x270815x580x325

9.5/27.5

10-14

126/264/298

750x250x190700x535x235

8/25.5

6.35 (1/4") 9.53 (3/8")

7000/80002.1/2.3

780/8003.5/3.6

8/26

9.5/28

90002.6

9.0, 2.64

52037/34/32

50

9804.4

8/26.5

9.5/28.5

14-21

9000/100002.6/2.9

2.88

980/10004.4/4.5

8/27

9.5/29

IMSJ-07CR-QB6 IMSJ-07HR-QB6 IMSJ-09CR-QB6 IMSJ-09HR-QB6

2.88

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

120003.5

9.0, 2.64

55038/35/33

52

220-240, 50, 113205.9

875x375x285910x575x335

11/36

18-26

108/226/266

790x265x200780x540x250

9.5/34

6.35 (1/4") 12.7 (1/2")

180005.3

9.0, 2.64

80042/39/37

56

20009.2

920x292x225

13.5/37

1015x370x295

15/39

30-40

18000/200005.3/5.8

2.81

2000/20609.2/9.4

IMSJ-12CR-QB6 IMSJ-12HR-QB6 IMSJ-18CR-QB6 IMSJ-18HR-QB6 IMSJ-21CR-QB5 IMSJ-21HR-QB5

100/210/245

210006.1

8.6, 2.52

92044/39/37

57

242011.2

845x690x33513.5/53

970x770x39515/57

34-49

66/142/163

21000/230006.1/6.7

2.72

2420/246011.2/11.4

13.5/54

15/58

12000/130003.5/3.8

1320/13505.9/6.1

2.82

Specification:

Page 12: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Cooling Only Cooling & Heating

220-240V~,50Hz

21 22

Aqua

Silver Ion Filter (Optional)

The Silver ion can kill bacteria or prevent their activity

at very low density by destroying their inner-

configuration and adsorbing their element in cells.

Meanwhile, the Nano Silver attached on the filter

release the Silver ion constantly to eliminate bacteria

effectively and continuously.

MSV3-07CR-QB8H

MSV3-07HR-QB8H

MSV3-09CR-QB8H

MSV3-09HR-QB8H

MSV3-12CR-QB8H

MSV3-12HR-QB8H

MSV3-07C(H)R-QB8H

MSV3-09C(H)R-QB8H

MSV3-12C(H)R-QB8H

Features:

Standard Optional

Temp. Compensation (optional)

The ceiling temperature is often higher than the floor

temperature. For example, floor temp. is 21oC, while

ceiling temp may be 25oC. By adopting temp.

compensation function, the temperature difference

can be eliminated. So if you set temp for 21oC, the

air-conditioner may make intell igent temp

compensation, setting the ceiling temp for 25oC, to

ensure the floor temp of 21oC.

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

Fresh AirMidea air conditioner have a pump in the indoor unit,

when press the "Fresh Air" button, the pump suck

the fresh air from outside, and the indoor polluted air

flow out of the room via the air pressure.

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

70002.1

9.7, 2.84

50034/31/29

50

220-240, 50, 17403.3

915x400x320815x580x325

10.5/27.5

10-14

106/220/258

805x270x205700x535x235

9/25.5

6.35 (1/4") 9.53 (3/8")

7000/80002.1/2.3

740/7303.3/3.3

9/26

10.5/28

90002.6

9.6, 2.84

52037/34/32

50

9204.2

9/26.5

10.5/28.5

14-21

9000/100002.6/2.9

3.1

920/9404.2/4.3

9/27

10.5/29

IMSV3-07CR-QB8H IMSV3-07HR-QB8H IMSV3-09CR-QB8H IMSV3-09HR-QB8H IMSV3-12CR-QB8H IMSV3-12HR-QB8H

120003.5

9.5, 2.81

55038/35/33

52

12505.6

970x400x320910x575x335

14/36

18-26

102/206/242

855x285x205780x540x250

12/34

12.7 (1/2")

12000/135003.5/3.9

1250/13005.6/5.8

3.1

12/35

14/37

3.14

Specification:

-2oC

+2oC

Page 13: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

220-240V~,50Hz

23 24

V ita

Cooling Only Cooling & Heating

Vitamin C Filter (Optional)

Vitamin C is one of necessary material for human

being, and it is also good for human skin. Vitamin C

Filter is made of Vitamin C Emission material. When

the air flows through it, the Vitamin C will be taken

everywhere in the room.

Progress of " Vitamin-C emission" every 6 hours

6hours 12hours 18hours 24hours0.0

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L)

Performance of the emission in case of Continuous running

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L) 0.70

0.65

0.60

0.55

0.50

0.45

0.30

0.30

0.35

1 day 2 days 3 days 4 days 5 days 6 days

The Silver ion can kill bacteria or prevent their activity

at very low density by destroying their inner-

configuration and absorbing their elements in cells.

Meanwhile, the Nano Silver attached on the filter

release the Silver ion constantly to eliminate bacteria

effectively and continuously.

Silver Ion Filter (Optional)

CSU-09/12YC(H)BC

CSU-18/21YC(H)AA

CSU-24YC(H)AA

Features:

Standard Optional

CSU-18YCAA

CSU-18YHAA

CSU-21YCAA

CSU-21YHAA

CSU-24YCAA

CSU-24YHAA

CSU-09YCBC

CSU-09YHBC

CSU-12YCBC

CSU-12YHBC

(09-12K) (18-24K)

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling

HeatingOperating Current Cooling

Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWWAA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

220-240,50,1810

3.8

12000/140003.5/4.0

1270

5.9

120003.5

1200

5.6

18-26

11.2, 2.90

500

9000/100002.6/3.0

8709303.94.3

9.8, 2.883.2

90002.6

10.6, 3.1

43037/32/28

52

815x290x203780x540x255

9/35

850x345x300920x615x390

12/39

14-21

90/188/210

6.35(1/4") 9.53(3/8")

ICSU-09YCBC ICSU-09YHBC ICSU-12YCBC ICSU-12YHBC

12.7(1/2")

3.14

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling

HeatingOperating Current Cooling

Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWWAA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

ICSU-18YCAA ICSU-18YHAA ICSU-21YCAA ICSU-21YHAA ICSU-24YCAA ICSU-24YHAA

18000/190005.0/7.3

1900

9

210006

2260

10.7

850x605x29014/47

1010x695x43017/51

34-49

9.1,2.65

70/140/170

21000/220006/6.3

2170

10.3

2.9

24000/250007.0/7.5

2590

11.3

2.9

180005.0

9.2,2.7

70043/38/35

53

220-240,50,11850

8.8

1015x320x190780x540x255

14/40

1050x370x290920x615x390

17/44

28-40

84/186/205

6.35(1/4") 12.7(1/2")

240007.0

2640

12.5

14/53

17/58

40-56

75035/46

58

9.53(3/8") 16.0(5/8")

2.9

Specification:

Page 14: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

220-240V~,50Hz

25 26

Helit

Cooling Only Cooling & Heating

Vitamin C Filter (Optional)

Vitamin C is one of necessary material for human

being, and it is also good for human skin. Vitamin C

Filter is made of Vitamin C Emission material. When

the air flows through it, the Vitamin C will be taken

everywhere in the room.

Progress of " Vitamin-C emission" every 6 hours

6hours 12hours 18hours 24hours0.0

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L)

Performance of the emission in case of Continuous running

Con

cent

ratio

n of

Asc

orbi

c A

cid(

mg/

L) 0.70

0.65

0.60

0.55

0.50

0.45

0.30

0.30

0.35

1 day 2 days 3 days 4 days 5 days 6 days

The Silver ion can kill bacteria or prevent their activity

at very low density by destroying their inner-

configuration and absorbing their elements in cells.

Meanwhile, the Nano Silver attached on the filter

release the Silver ion constantly to eliminate bacteria

effectively and continuously.

Silver Ion Filter (Optional)

CSU-05HCAA

CSU-07/09/12HC(H)AA

CSU-18HC(H)AA

CSU-21/24HC(H)AA

Features:

Standard Optional

CSU-05HCAA CSU-07HCAA

CSU-07HHAA

CSU-09HCAA

CSU-09HHAA

CSU-12HCAA

CSU-12HHAA

CSU-18HCAA

CSU-18HHAA

CSU-21HCAA

CSU-21HHAA

CSU-24HCAA

CSU-24HHAA

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling

HeatingOperating Current Cooling

Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWWAA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

ICSU-05HCAA ICSU-07HCAA ICSU-07HHAA ICSU-09HCAA ICSU-09HHAA

90002.6

870

4.1

9.8,2.88

14-21

9000/100002.6/2.9

9108604.24.0

9.4,2.753.25

7000/75002.0/2.2

6807203.13.2

10.0,2.943.06

220-240,50,1540

2.5

50001.5

9.5, 2.80

42035/32/26

52

740x243x200600x502x232

7/23

785x295x260735x565x370

9/26

8-10

126/270/322

6.35(1/4") 9.53(3/8")

70002.0

670

3.2

10-14

10.2,2.98

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling

HeatingOperating Current Cooling

Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWWAA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

ICSU-12HCAA ICSU-12HHAA ICSU-18HCAA ICSU-18HHAA ICSU-21HCAA ICSU-21HHAA ICSU-24HCAA ICSU-24HHAA

180005.3

1890

8.9

1015x320x190

14/40

1050x370x290

17/44

28-49

65043/38/34

53

84/186/205

18000/190005.3/5.5

1820

8.6

3.03

21000/220006.1/6.5

2250

10.6

2.89

120003.5

9.1, 2.65

50039/34/29

52

220-240, 50, 11320

6.3

740x243x200780x540x255

8/35

785x295x260920x615x390

9/39

18-26

108/220/250

6.35(1/4") 12.7(1/2")

210006.1

2280

10.8

850x605x29014/47

1010x695x43017/51

34-49

9.0, 2.63

70044/39/35

54

70/140/170

24000/260007.0/7.6

2770273013.112.9

8.7, 2.532.78

240007.0

2680

12.7

14/53

17/58

40-56

8.9, 2.61

75046/39/35

56

9.53(3/8") 16.0(5/8")

12000/130003.5/3.9

2.84

1370

6.5

Specification:

Page 15: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Vitamin C Filter (Optional)

Vitamin C is one of necessary material for human

being, and it is also good for human skin. Vitamin C

Filter is made of Vitamin C Emission material. When

the air flows through it, the Vitamin C will be taken

everywhere in the room.

The abundance of anions present at waterfall, rivulet

and in forest soothes and refreshes people. Midea

air conditioners have taken

advan tage o f Ion ize r

Technology to bring the

refreshing air to your home.

220-240V~,380V~,50Hz

Ionizer (Optional)

27

Cooling Only Cooling & Heating

28

Glory FamilyF

AM

ILY

MSG-05/07/09/C(H)R

MSG-12C(H)R

MSG-18/21C(H)R

MSG-24/30C(H)R

MSG-36C(H)R

Features:

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

20'/40'/40'HQ

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

IMSG-05CR IMSG-07CR IMSG-07HR IMSG-09CR IMSG-09HR IMSG-12CR IMSG-12HR IMSG-18CR IMSG-18HR IMSG-21CR IMSG-21HR

2.95

12000/130003.5/3.8

1230/12905.7/6.0

10/39

120003.5

9.8, 2.87

55041/38/34

52

12305.7

910x575x33510/37

113/238/280

18-26

9000/100002.6/2.9

2.99

960/9804.5/4.6

10/33

90002.6

9.4, 2.75

45037/34/31

50

9604.5

10/32

14-21

7000/76002.1/2.2

760/7603.6/3.6

10/31

70002.1

9.2, 2.70

380

7603.6

10/30

10-14

50001.5

9.0, 2.62

30032/30/28

49

220-240,50,1 560 2.6

830x336x280815x580x325

9.5/29

8-12

9.4, 2.75

75041/38/35

53

180005.3

19209.0

1020x380x328

16.5/41

30-40

2.96

18000/200005.3/5.9

1920/19809.0/9.2

16.5/42

8.5/36780x540x250

8.5/348.5/308.5/298.5/288.5/27

750x250x196700x535x235 8.0/26

906x286x245

13.5/38 13.5/39

103/205/234

Electrical Parts

12.7(1/2")6.35(1/4")9.53(3/8")

126/260/290

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

9.1, 2.68

80043/39/36

54

210006.2

230010.5

34-49

2.87

21000/235006.2/6.9

2300/240010.5/11.0

16.5/60

845x695x33513.5/52 13.5/55

66/142/163

970x770x39516.5/57

Capacity

2.93

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

20'/40'/40'HQ

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

IMSG-24CR IMSG-24HR IMSG-30CR IMSG-30HR IMSG-36CR IMSG-36HR IMSG-30CR IMSG-30HR IMSG-36CR IMSG-36HR

28000/300008.2/8.8

3200/310015.0/14.5

280008.2

320015.0

50-68

24000/270007.0/7.9

2750/275012.5/12.5

240007.0

220-240,50,1275012.5

40-56

35000/3800010.3/11.1

4120/410018.6/18.5

17/6917/6717/60

1080x330x232845x695x335

17/58 18/82

9.53(3/8")16.0(5/8")

60/127/142

Capacity

Performance

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

EERCOPAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Outdoor

280008.2

380,50,330005.3

28000/320008.2/9.4

3000/30005.3/5.3

1080x330x232845x695x335

17/67 17/69

50-68

60/127/142

3500010.3

41206.5

35000/3800010.3/11.1

4120/41006.5/6.4

1250x325x240895x860x330

18/80 18/82

60-78

44/96/106

3500010.3

412018.6

1250x325x240895x860x330

18/80

60-78

44/96/106

22/7422/7222/65

1165x445x320970x770x395

22/63 24/87

1165x445x320970x770x395

22/72 22/74

1345x430x3351045x930x395

24/85 24/87

1345x430x3351045x930x395

24/85

Electrical Parts

2.848.8, 2.56

115047/44/41

58

8.7, 2.55

105043/40/37

56

2.729.3, 2.74

115047/44/41

58

3.138.5, 2.49

135049/46/42

59

2.728.5, 2.49

135049/46/42

59

2.88

Net Dimension & Weight

Specification:

Glory Single

Single

MSG-05CR MSG-07CRMSG-07HR

MSG-09CRMSG-09HR

MSG-12CRMSG-12HR

MSG-18CRMSG-18HR

MSG-21CRMSG-21HR

MSG-24CRMSG-24HR

MSG-30CRMSG-30HR

MSG-36CRMSG-36HR

Multi

MS2GI-21CR MS3GI-27CRMS2GI-18CR

AC Inverter

MSG-21HRIMSG-12HRIMSG-09HRI MSG-24HRI

AC Inverter Multi

MS2G-18HRI

Standard Optional

Page 16: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Model

Btu/hkW

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWWAA

Set

m2

IMSG-09HRI IMSG-12HRI IMSG-21HRI IMSG-24HRI

12000(3070~12300)3.5(0.9~3.6)

15000(3070~17060)4.4(0.9~5.0)

8.7, 2.552.46600

38/34/2853

1380(310~1710)1790(300~2380)

7.4(1.6~8.8)10.5(1.6~12.3)

815x280x205

11/40

915x360x275

14/43

20-30

108/226/266

9000(2730~10600)2.6(0.8~3.1)

12000(2730~14000)3.5(0.8~4.1)

8.3, 2.442.66500

36/32/2650

220-240,50, 11080(270~1470)1350(270~1800)6.0(1.45~7.6)7.2(1.45~9.3)

750x250x196760x590x285

8.5/36

830x336x280890x655x360

11/39

18-24

113/238/274

6.35(1/4") 9.53(3/8")

21000(9500~25000)6.2(2.8~7.3)

28000(12000~30000)8.2(3.5~8.8)

8.6, 2.512.931150

45/42/3955

2450(1250~3100)2800(1600~3450)12.0(6.4~15.5)14.0(7.7~17.3)

1080x330x232845x695x335

17/60

1165x445x320970x770x395

22/65

34-49

60/127/142

9.53(3/8") 16.0(5/8")

Voltage,Frequency,PhasePower Input Cooling

HeatingOperating Current Cooling

Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

20'/40'/40'HQ

Cooling

Heating

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

24000(10000~27000)7.0(2.9~7.9)

30000(13000~33000)8.8(3.8~9.7)

2700(1300~3350)3030(1700~3800)13.2(6.6~16.7)15.1(8.2~18.7)

40-56

8.9, 2.612.90

29 30

Cooling & Heating

Specification:

Outdoor unit

Cooling Only

Indoor unit

MSGI-09CR

MSG-12CR

Features:

MSG-09HRI

MSG-12HRI

MSG-21/24HRI

Features:

Model IMSGI-09CR IMSGI-12CRCapacity Cooling/HeatingAir Flow High/Medium/LowDimension (WxHxD)Packing (WxHxD)Net/Gross WeightIndoor noise level (Hi/Mi/Lo)Liquid side/Gas side

Btu/hm3/hmmmm

kgdB(A)

mm 6.35/ 9.53

9000/10000550

750x250x196830x336x280

8.5/1037/34/31

12000/13000580

41/38/346.35/ 12.7

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

IM2OA-18CR IM2OA-21CR IM3OA-27CRModel

Cooling/Heating Btu/hkW

V~,Hz,PhWA

Capacity

Electrical Data

PerformanceBtu/W.h, W/W

mmmm

kgm3/h

dB(A)

EERDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level

9000+120002.6+3.5

890+13004.4+6.1

9.3

74/80

9000x22.6x2

220-240, 50, 1890x23.9x2

6500x2+90001.9x2+2.6

1190+7905.2+3.3

10.1895x655x3451050x720x470

73/79200055

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

mm(inch)mm(inch)

Piping ConnectionLiquid SideGas Side

6.35(1/4")x2 9.53(3/8")x2

6.35(1/4") / 6.35(1/4") 9.53(3/8") / 12.7(1/2")

6.35(1/4")x3 9.53(3/8")x3

11.1

12.7(1/2")

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

Specification:

Glory Multi Glory AC Inverter

Standard Optional

Standard Optional

Page 17: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

31

Specification:

Indoor unit

Model IMSGI-09HRICapacity Cooling/HeatingAir Flow HighDimension (WxHxD)Packing (WxHxD)Net/Gross WeightIndoor noise level (Hi/Mi/Lo)Liquid side/Gas side

Btu/hm3/h

mmmm

kgdB(A)

mm 6.35/ 9.53

9000/10000500

750x250x188830x336x280

8.5/1035/32/29

Floor-standing

Cooling & Heating

MSGI-09HRI

Features:

Outdoor unit

Model

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

IMS2G-18HRI

Voltage,Frequency,PhasePower Input Cooling

HeatingOperating Current Cooling

Heating

EERCOPNet Dimension WxHxDPacking Dimension WxHxDNet/Gross WeightOutdoor air flowOutdoor noise level

Liquid SideGas Side

Cooling

Heating

Btu/hkW

Btu/hkW

Btu/W.h, W/WW/Wmmmm

kgm3/hdB(A)

mm(inch)mm(inch)

V~,Hz,PhWWAA

Capacity

Electrical Parts

Performance

Piping Connection 6.35(1/4")x2 9.53(3/8")x2

Glory AC Inverter Multi

Standard Optional

845x695x335970x770x395

59/65200013

8.6, 2.532.55

9500(3400~11000)2.8(1.0~3.22)

12600(5100~14300)3.7(1.49~4.19)

220-240, 50, 1 1100(350~1340)1450(630~1910)

5.5(1.8~6.9)6.9(3.3~9.9)

Single Double9000(2700~9500)x22.6(0.79~2.78)x2

11000(3400~12300)x23.2(1.0~3.6)x2

8.2, 2.402.71

2200(570~2350)2400(700~2670)11.5(3.0~12.2)12.5(3.6~13.8)

Page 18: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

F loor-standing

33 34

MFV-18C(H)R

MFV-21C(H)R

MFV-24C(H)R

MFV-28C(H)R

Features:

MFS2-24C(H)R

MFS2-24AR

MFS2-48C(A)R

Features:

V Floor-standingMFV-18CR

MFV-18HR

MFV-21CR

MFV-21HR

MFV-24CR

MFV-24HR

MFV-28CR

MFV-28HR

J Floor-standingMFJ-18CR-QB6

MFJ-18HR-QB6

MFJ-21CR-QB6

MFJ-21HR-QB6

MFJ-24CR-QB6

MFJ-24AR-QB6

MFJ-24CR-RB6

MFJ-24AR-RB6

MFJ-48CR-RB4

MFJ-48AR-RB4

S2 Floor-standingMFS2-24CR

MFS2-24HR MFS2-24AR

MFS2-48CR

MFS2-48AR

E Floor-standingMFE-60CE

MFE-60AE

MFJ-18C(H)R-QB6

MFJ-21C(H)R-QB6

MFJ-24C(A)R-QB6

MFJ-48C(A)R-RB4

Features:

MFE-60CE

MFE-60AE

Features:

Standard Optional

220-240V~,380-420V~,50Hz

Standard Optional

Standard Optional

Standard Optional

Page 19: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Cooling Only Cooling & Heating

35 36

F loor-standing

Cooling Only Cooling & Heating

220-240V~,380-420V~,50Hz

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMFV-18CR IMFV-18HR IMFV-21CR IMFV-21HR IMFV-24CR IMFV-24HR

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

180005.1

10.7, 3.15

88041/36

56

220-240, 50, 116207.5

620x1870x433970x770x395

49/57

30-40

32/74/83

500x1750x300845x695x335

36/52

6.35 (1/4") 12.7 (1/2")

18000/200005.1/5.8

39/53

52/58

210006.1

10.8, 3.16

92043/39

57

19308.8

36/53

49/58

34-49

21000/230006.1/6.7

3.5

1930/19208.8/8.8

39/54

52/59

240007.2

10.3, 3.01

95044/38

58

240011.1

1045x915x39550/67

40-56

28/62/68

895x860x33037/59

9.53 (3/8") 16.0 (5/8")

24000/280007.2/8.2

3.48

2400/235011.1/10.9

40/59

53/67

3.54

1620/16407.5/7.6

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMFV-28CR IMFV-28HR IMFV-28CR IMFV-28HR

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

280008.2

9.51, 2.79

110046/40

58

220-240, 50, 1294013.5

620x1870x4331045X915X395

51/71

50-68

28/62/68

500x1750x300895x860x330

38/63

9.53 (3/8") 16.0 (5/8")

28000/300008.2/8.8

3.23

2940/273013.5/12.6

41/70

53/78

280008.2

380, 50, 329404.7

38/63

51/71

28000/300008.2/8.8

3.23

2940/27304.7/4.4

41/70

53/78

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

180005.1

8.9, 2.6

88044/38

56

220-240, 50, 119608.5

580x1780x400970x770x395

46/41

24-37

35/74/84

480x1680x290845x695x335

33/38

6.35 (1/4") 12.7 (1/2")

18000/195005.1/5.7

1960/19008.5/8.3

33/39

46/42

210006.1

95046/40

58

235010.2

500x1700x290845x695x335

38/52

600x1800x423970x770x395

51/57

29-45

21000/225006.1/6.6

3.0

2350/220010.2/9.6

39/55

52/60

240007.1

110048/42

60

273011.9

51/71

34-53

38/63

24000/270007.1/7.9

3.0

2730/263011.9/11.4

38/65

51/73

9.53 (3/8") 16.0 (5/8")

35/74/84

IMFJ-18CR-QB6 IMFJ-18HR-QB6 IMFJ-21CR-QB6 IMFJ-21HR -QB6 IMFJ-24CR-QB6 IMFJ-24AR-QB6

3.0

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

240007.1

8.9, 2.6

110048/42

60

380-420, 50, 327304.5

600x1800x423970x770x395

51/71

34-53

35/74/84

500x1700x290845x695x335

38/63

9.53 (3/8") 16.0 (5/8")

24000/270007.1/7.9

2730/26304.5/4.4

38/69

51/77

4800014.0

8.2, 2.4

180054/48

62

58309.4

540x1825x425990x1250x340

56/92

660x1945x5581020x1377x435

69/100

68-96

48000/4900014.0/14.4

2.5

5830/57609.4/9.4

56/104

69/112

12.7 (1/2") 19.0 (3/4")

22/46/56

IMFJ-24CR -RB6 IMFJ-24AR-RB6 IMFJ-48CR-RB4 IMFJ-48AR-RB4

3.0

Specification_J Floor-standingSpecification_V Floor-standing

Page 20: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Cooling Only Cooling & Heating

37

F loor-standing Window

Portable

Dehumidifier

220-240V~,380V~,50Hz

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMFS2-24CR IMFS2-24CR IMFS2-24HR IMFS2-24AR IMFS2-24AR IMFS2-48CR IMFS2-48AR

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

240007.0

9.1, 2.65

100045/42/39

52

220-240, 50, 1265012.3

585x1805x380965x772x395

57/67

40-56

43/87/97

500x1665x273845x695x335

46/43

9.53 (3/8") 16.0 (5/8")

24000/280007.0/8.2

3.10

220-240, 50, 12650/265012.3/12.3

46/66

57/70

380, 50, 3

4.8

24000/28000+72007.0/8.2+2.1

2650/2650+210012.3/12.3+10.0

46/69

57/74

24000/28000+85007.0/8.2+2.5

380, 50, 32650/2650+2500

4.8/4.8+4.4

4800014.1

9.4, 2.75

200048/45/42

55

51008.6

665x1915x4751120x1090x435

71/105

80-120

25/48/50

540x1775x379990x960x360

56/90

12.7 (1/2") 19.0 (3/4")

48000/52000+1200014.1/15.2+3.5

2.99

5100/5100+35008.6/8.6+5.8

57/92

72/107

12.7 (1/2") 19.0 (3/4")

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'/40'HQ

Model

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

EERCOPAir Flow Volume IndoorNoise Level Indoor (Hi/Med/Lo)

Outdoor

Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor

Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor

Liquid SideGas Side

Cooling/Heating

IMFE-60CE IMFE-60AE

Btu/hkW

Btu/W.h, W/WW/Wm3/hdB(A)dB(A)

mmmm

kg

mmmm

kg

mm(inch)mm(inch)

V~,Hz,PhWA

Set

m2

Capacity

Electrical Parts

Performance

Net Dimension & Weight

Packing Dimension & Gross Weight

Piping Connection

Applicable Area

Stuffing Quantity

6000017.6

9.4, 2.75

220053/50/47

63

380, 50, 3630011.0

100-130

600x1900x358940x1245x360

65/114

60000/60500+1450017.6/17.7+4.2

6300/6300+420011.0/11.0+7.3

65/116

75/131

685x1985x4501020x1370x435

75/129

21/45/50

2.81

Specification_S2 Floor-standing

Specification_E Floor-standing

Page 21: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

F Window 220-240V~,50Hz

Cooling Only Cooling & Heating

Unique QuietDesign

Easy RemovedPanel

Fresh Air Switch Sliding Chassis Two DrainageMethods

Features:

MWF-05CM

MWF-07CM

MWF-09CM

MWF-12CM

MWF-16CM

MWF-18CM

MWF-21CM

MWF-24CM

MWF-28CM

MWF-07CR

MWF-09CR

MWF-12CR

MWF-16CR

MWF-18CR

MWF-21CR

MWF-24CR

MWF-28CR

MWF-07HR

MWF-09HR

MWF-12HR

MWF-16HR

MWF-18HR

MWF-21HR

MWF-24HR

MWF-07HM

MWF-09HM

MWF-12HM

MWF-16HM

MWF-18HM

MWF-21HM

MWF-24HM

20'/40'HQ

Model

Power SupplyPower Input CoolingOperating Current Cooling

Cooling Btu/hkW

Btu/W.hW/Wm3/hdB(A)

mmkg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Weight

Applicable Area

Stuffing Quantity

50001.5

220-240, 50, 15002.2

8-12

120003.5

18-26

132/342

600x380x56043

Capacity

IMWF-05CM IMWF-07CM IMWF-09CM IMWF-12CM IMWF-16CM IMWF-18CM IMWF-21CM IMWF-24CM IMWF-28CM

445x320x40026

EER

Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDNet Weight

mmkg

Packing Dimension & Gross Weight685x430x620

47500x380x455

28Packing Dimension WxHxDGross Weight

330/840

9.62.8253051

12405.6

160004.7

23-30

84/220

660x430x68753.5

746x515x81558

16407.5

210006.2

35-50

58

63

235010.8

92.6475056

IMWF-07CR IMWF-09CR IMWF-12CR IMWF-16CR IMWF-18CR IMWF-21CR IMWF-24CR IMWF-28CR

90002.6

9.52.7840047

9404.2

14-20

35

39

70002.1

10.12.9635046

6903.2

11-16

450x346x53531.5

495x435x58035

220/572

9.72.8670054

240007.0

40-56

290013.5

8.3 2.4382059

280008.2

50-68

340015.3

8.22.4195061

770x495x91577

102.9325043

72/192

80

88

20'/40'HQ

Model

Power SupplyPower Input CoolingOperating Current Cooling

Cooling Btu/hkW

Btu/W.hW/Wm3/hdB(A)

mmkg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Weight

Applicable Area

Stuffing Quantity

7000/70002.1/2.1

9.3, 2.723.0235046

220-240, 50, 1750/6803.2/2.9

11-16

12000/120003.5/3.5

18-26

132/342

600x380x56043

CapacityIMWF-07HR IMWF-09HR IMWF-12HR IMWF-16HR IMWF-18HR IMWF-21HR IMWF-24HRIMWF-07HM IMWF-09HM IMWF-12HM IMWF-16HM IMWF-18HM IMWF-21HM IMWF-24HM

450x346x53531.5

EERCOPAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDNet Weight

mmkg

Packing Dimension & Gross Weight685x430x620

47495x435x580

35Packing Dimension WxHxDGross Weight

220/572

9.6, 2.822.98 53051

1240/11705.6/5.3

18000/180005.3/5.3

30-40

1880/17408.5/7.9

16000/160004.7/4.7

23-30

660x430x68753.5

746x515x81558

84/220

1640/15407.5/7.0

9.7, 2.86 3.0670054

9000/90002.6/2.6

9.5, 2.78

40047

940/8604.2/3.9

54

59

21000/210006.2/6.2

35-50

2350/220010.8/10.1

58

63

24000/240007.0/7.0

40-56

2900/280013.5/12.9

72/192

35660x430x770

68

39770x495x915

77

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

39 40

Bio Filter(Optional)

Slinger-UpSystem

180005.3

30-40

9.62.81730

18808.7

660x430x77068

9.6, 2.813.0573055

9.0, 2.642.8275056

8.3, 2.432.5392059

14-20

(Optional)

Page 22: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Cooling Only Cooling & Electric HeaterCooling Only Cooling & Electric Heater

Features:

M1 Portable K1 Portable

Features:

PTC HeaterFlexible ExhaustThrough the

Wall or Window

Flexible Exhaust Hose

AdjustableWindow Slider Kit

Ionizer(Optional)

LCD Display(Optional)

ShowerCooling System

Exterior WaterInput System

PTC HeaterLED Display Flexible ExhaustThrough the Wall

or Window

FlexibleExhaust Hose

ShowerCooling System

AdjustableWindow Slider Kit

Ionizer(Optional)

MPM1-09CR-QB6 MPM1-09ER-QB6

MPM1-10CR-QB6 MPM1-10ER-QB6

MPM1-12CR-QB4 MPM1-12ER-QB4

MPM1-14CR-QB4 MPM1-14ER-QB4

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'HQ

Model

Power SupplyPower Input Cooling/HeaterOperating Current Cooling/Heater

EERMoisture RemovalAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDNet Weight

Cooling/Heater Btu/hkW

Btu/W.h,W/WL/h

m3/hdB(A)

mmkg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Net Weight

Applicable Area

Stuffing Quantity

CapacityIMPM1-09CR-QB6 IMPM1-09ER-QB6 IMPM1-10CR-QB6 IMPM1-10ER-QB6 IMPM1-12CR-QB4 IMPM1-12ER-QB4 IMPM1-14CR-QB4 IMPM1-14ER-QB4

90002.6

220-240, 50, 19804.4

480x840x36534

14-21

88/270

9.0, 2.641.7460

50/48/46

IMPM1-09CE-QB6 IMPM1-09EE-QB6 IMPM1-10CE-QB6 IMPM1-10EE-QB6 IMPM1-12CE-QB4 IMPM1-12EE-QB4 IMPM1-14CE-QB4 IMPM1-14EE-QB4

Packing Dimension WxHxDGross Weight

mmkg

Packing Dimension & Gross Weight670x890x435

42

9000/61002.6/1.8

120003.5

14206.5

18-26

8.4, 2.461.9500

53/51/48

12000/61003.5/1.8

980/18004.4/8.2

1420/18006.5/8.2

34.5

16-24

8.9, 2.611.8480

51/49/46

43

100002.9

11205.1

10000/61002.9/1.8

1120/18005.1/8.2

38

45

140004.1

16907.7

20-28

8.3, 2.422.0520

54/52/49

38

46

14000/61004.1/1.8

1690/18007.7/8.2

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'HQ

Model

Power SupplyPower Input Cooling/HeaterOperating Current Cooling/Heater

EERMoisture RemovalWater Tank VolumeAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDNet Weight

Cooling/Heater Btu/hkW

Btu/W.h,W/WL/h

Lm3/hdB(A)

mmkg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Net Weight

Applicable Area

Stuffing Quantity

CapacityIMPK1-09CR-QB4 IMPK1-09ER-QB4 IMPK1-10CR-QB4 IMPK1-10ER-QB4 IMPK1-12CR-QB4 IMPK1-12ER-QB4 IMPK1-14CR-QB4 IMPK1-14ER-QB4

90002.6

220-240, 50, 110804.9

460x840x32533

14-21

90/290

8.9, 2.411.63.5460

52/50/47

IMPK1-09CE-QB4 IMPK1-09EE-QB4 IMPK1-10CE-QB4 IMPK1-10EE-QB4 IMPK1-12CE-QB4 IMPK1-12EE-QB4 IMPK1-14CE-QB4 IMPK1-14EE-QB4

Packing Dimension WxHxDGross Weight

mmkg

Packing Dimension & Gross Weight695x870x412

41

9000/61002.6/1.8

120003.5

14306.5

18-26

8.4, 2.451.8

50053/51/48

12000/61003.5/1.8

1080/18004.9/8.2

1430/18006.5/8.2

16-24

8.3, 2.441.7

480

100002.9

11905.4

10000/61002.9/1.8

1190/18005.4/8.2

460x840x37238

695x870x47446

140004.1

16807.7

20-28

8.3, 2.431.9

520

14000/61004.1/1.8

1680/18007.7/8.2

80/250

220-240V~,50Hz 220-240V~,50Hz

Vitamin C Filter(Optional)

Bio Filter(Optional)

Vitamin C Filter(Optional)

Bio Filter(Optional)

Remote Control

Electronic Control

41 42

Silver Ion(Optional)

Silver Ion(Optional)

MPK1-09CR-QB4 MPK1-09ER-QB4

MPK1-10CR-QB4 MPK1-10ER-QB4

MPK1-12CR-QB4 MPK1-12ER-QB4

MPK1-14CR-QB4 MPK1-14ER-QB4

MPK1-09CE-QB4 MPK1-09EE-QB4

MPK1-10CE-QB4 MPK1-10EE-QB4

MPK1-12CE-QB4 MPK1-12EE-QB4

MPK1-14CE-QB4 MPK1-14EE-QB4

MPM1-09CE-QB6 MPM1-09EE-QB6

MPM1-10CE-QB6 MPM1-10EE-QB6

MPM1-12CE-QB4 MPM1-12EE-QB4

MPM1-14CE-QB4 MPM1-14EE-QB4

Remote Control

Electronic Control

Page 23: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Cooling Only Cooling & Electric Heater

Features:

220-240V~,50HzK Portable F Portable

Cooling Only Cooling & Electric Heater

Features:

PTC HeaterFlexibleExhaust Hose

AdjustableWindow Slider Kit

LED Display Flexible ExhaustThrough the Wall

or Window

220-240V~,50Hz

R407C

43 44

Ionizer(Optional)

PTC HeaterFlexibleExhaust Hose

AdjustableWindow Slider Kit

Flexible ExhaustThrough the Wall

or Window

LED DisplayShowerCooling System

MPK-09CR MPK-09ER

MPK-10CR MPK-10ER

MPK-12CR-QB4 MPK-12ER-QB4

MPK-14CR-QB4 MPK-14ER-QB4

MPK-09CE MPK-09EE

MPK-10CE MPK-10EE

MPK-12CE-QB4 MPK-12EE-QB4

MPK-14CE-QB4 MPK-14EE-QB4

Silver Ion(Optional)

Water PumpUp To 4m High

MPF-09CRN2 MPF-09ERN2

MPF-10CRN2 MPF-10ERN2

MPF-12CRN2 MPF-12ERN2

MPF-14CRN2 MPF-14ERN2

MPF-09CEN2 MPF-09EEN2

MPF-10CEN2 MPF-10EEN2

MPF-12CEN2 MPF-12EEN2

MPF-14CEN2 MPF-14EEN2

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'HQ

Model

Power SupplyPower Input Cooling/HeaterOperating Current Cooling/Heater

EERMoisture RemovalWater Tank VolumeAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDNet Weight

Cooling/Heater Btu/hkW

Btu/W.h,W/WL/h

Lm3/hdB(A)

mmkg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Net Weight

Applicable Area

Stuffing Quantity

CapacityIMPK-09CR IMPK-09ER IMPK-10CR IMPK-10ER IMPK-12CR-QB4 IMPK-12ER-QB4 IMPK-14CR-QB4 IMPK-14ER-QB4

90002.6

220-240, 50, 110804.9

460x840x32533

14-21

90/290

8.9, 2.411.63.5420

52/50/47

IMPK-09CE IMPK-09EE IMPK-10CE IMPK-10EE IMPK-12CE-QB4 IMPK-12EE-QB4 IMPK-14CE-QB4 IMPK-14EE-QB4

Packing Dimension WxHxDGross Weight

mmkg

Packing Dimension & Gross Weight695x870x412

41

9000/61002.6/1.8

120003.5

14306.5

18-26

8.4, 2.451.8

48053/51/48

12000/61003.5/1.8

1080/18004.9/8.2

1430/18006.5/8.2

16-24

8.3, 2.441.7

440

100002.9

11905.4

10000/61002.9/1.8

1190/18005.4/8.2

460x840x37238

695x870x47446

140004.1

16807.7

20-28

8.3, 2.431.9

500

14000/61004.1/1.8

1680/18007.7/8.2

80/250

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'HQ

Model

Power SupplyPower Input Cooling/HeaterOperating Current Cooling/Heater

EERMoisture RemovalWater Tank VolumeAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDNet Weight

Cooling/Heater Btu/hkW

Btu/W.h,W/WL/h

Lm3/hdB(A)

mmkg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Net Weight

Applicable Area

Stuffing Quantity

CapacityIMPF-09CRN2 IMPF-09ERN2 IMPF-10CRN2 IMPF-10ERN2 IMPF-12CRN2 IMPF-12ERN2 IMPF-14CRN2 IMPF-14ERN2

90002.6

220-240, 50, 110804.9

480x840x40034

14-21

80/263

8.9, 2.411.63

42051/49/46

IMPF-09CEN2 IMPF-09EEN2 IMPF-10CEN2 IMPF-10EEN2 IMPF-12CEN2 IMPF-12EEN2 IMPF-14CEN2 IMPF-14EEN2

Packing Dimension WxHxDGross Weight

mmkg

Packing Dimension & Gross Weight655x875x445

42

9000/61002.6/1.8

120003.5

13006.0

18-26

9.0, 2.631.8

48053/51/48

12000/61003.5/1.8

1080/18004.9/8.2

1330/18006.0/8.2

16-24

9.1, 2.661.7

440

100002.9

11004.9

10000/61002.9/1.8

1100/18004.9/8.2

140004.1

15507.0

20-28

1.9

500

37

45

14000/61004.1/1.8

1550/18007.0/8.2

35

43

36.5

44

Silver Ion(Optional)

Electronic Control

Remote Control Remote Control

Electronic Control

Bio Filter(Optional)

Vitamin C Filter(Optional)

Page 24: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Features:Cooling Only

Mini Portable F Dehumidifier220-240V~,50Hz

Features:

Flexible ExhaustThrough the Wall

or Window

Adjustable Window Slider Kit

FlexibleExhaust Hose

LED Display

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20'/40'HQ

Model

Power SupplyPower Input Cooling/HeaterOperating Current Cooling/Heater

EEREnergy RateMoisture RemovalWater Tank VolumeAir Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)

Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight

Cooling/Heater Btu/hkW

Btu/W.hW/W

L/hL

m3/hdB(A)

mmmm

kg

V~,Hz,PhWA

Set

m2

Electrical Data

Performance

Net Dimension & Weight

Applicable Area

Stuffing Quantity

CapacityIMPM-07CR-QB6

70002.1

220-240, 50, 18003.5

450x737x340675x790x395

28/34

10-14

142/299

9.12.670.93

28051/48/45

MDF-09DMN3 MDF-09DEN3 MDF-12DMN3 MDF-12DEN3ModelMoisture Removal 30OC,RH80%Power SuplyPower Input 30OC,RH80%Operating Current 30OC,RH80%Air Flow VolumeWater Tank VolumeNoise LevelNet Dimension WxHxDPacking Dimension WxHxDNet/Gross WenghtApplicable AreaStuffing Quantity 20'/40'HQ

L/dayV~,Hz,Ph

WA

m3/hL

dB(A)mmmmKgm2

Set

9220-240, 50, 1

2101.11002.740

315x505x235380x610x315

13/169-15

440/905

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

12

2401.2120

41

12-20

220-240V~,50Hz

Vitamin C Filter(Optional)

Bio Filter(Optional)

Bio Filter(Optional)

Vitamin C Filter(Optional)

Easy-removablefilter

ConvenientHandle

HumiditySensor

RemovableBucket

Powerful Dehumidification

MDF-09DEN3

MDF-12DEN3

Electronic Control

MDF-09DMN3

MDF-12DMN3

Mechanical ControlR134a

45 46

IMPM-07CE-QB6

Silver Ion(Optional)

Silver Ion(Optional)

MPM-07CR-QB6

MPM-07CE-QB6

Remote Control

Electronic Control

Page 25: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Free Joint Multi

Features:

Dehumidifier

RemovableDust Filter

Semi-HiddenCaster

ConvenientHandle

Humidity SensorTransparent Water Level Indication

Remove WaterTank Up to 4 Litre

Powerful Dehumidification

MDB-14DMN3 MDB-14DEN3 MDB-20DMN3 MDB-20DEN3ModelMoisture Removal 30OC,RH80%Power SuplyPower Input 30OC,RH80%Operating Current 30OC,RH80%Air Flow VolumeWater Tank VolumeNoise LevelNet Dimension WxHxDPacking Dimension WxHxDNet/Gross WenghtApplicable AreaStuffing Quantity 20'/40'HQ

L/dayV~,Hz,Ph

WA

m3/hL

dB(A)mmmmKgm2

Set

14220-240,50,1

3001.8130443

320x620x280385x660x350

20/2212-24

288/808

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

20

4002.0150

44

18-30

220-240V~,50Hz

MDB-14DMN3

MDB-20DMN3

Mechanical Control

MDB-14DEN3

MDB-20DEN3

Electronic Control

R134a

47

Silver Ion(Optional)

Page 26: Cover Midea R22 - Klimauredjaji.com 2007.pdf · Midea Is Your Idea 50Hz 2007 GD Midea Air-conditioning Equipment Co., Ltd. Add: Midea Industrial City, Shunde, Foshan, Guangdong 528311

Indoor unit

220-240V~,50Hz

6.35/ 9.53 6.35/ 9.53

Cooling/Heating

Model

Dimension (WxHxD) BodyPanel

Packing (WxHxD) BodyPanel

Net/Gross Weight BodyPanel

Air flow volumeIndoor noise levelLiquid side/Gas side

CapacityBtu/h

mmmmmmmm

kgkg

m3/hdB(A)

mm

9000/10000

750x250x188

830x336x280

8.5/10.5

52030

12000/13000

815x280x195

915x360x275

10.5/13.5

56031

9000/11000Performance

955x210x385

1114x277x469

15/19

55034

6.35/ 12.7

12000/15000 12000/15000

68058035

9000/11000

580x254x580650x30x650750x340x750715x115x715

21/303/5600

6.35/ 12.7 6.35/ 9.53 6.35/ 12.7

Multi Star

Outdoor unit

Cooling & Heating

M2OA-18HR

M2OA-21HR

M3OA-27HR

M3OA-30HR

2-Compressor Dual Split TypeTwo constant-speed compressors independently

drive two indoor units.

Outdoor Unit Indoor Units

COMP

A

COMP

B B

A

IMSGI-09HR IMSGI-12HR IMST2I-09HR IMST2I-12HR IMSQ4I-09HR IMSQ4I-12HR

Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.

Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating

IM2OA-18HR IM2OA-21HR IM3OA-27HR IM3OA-30HRModel

Cooling/Heating Btu/hkW

V~,Hz,PhWA

Capacity

Electrical Data

PerformanceBtu/W.h, W/W

W/Wmmmm

kgm3/hdB(A)

EERCOPDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level

9000+12000/10000+130002.6+3.5/2.9+3.8

920+1220/900+11505.0+6.0/5.0+6.0

9.81, 2.853.27

79/83

9000x2/10000x22.6x2/2.9x2

220-240, 50, 1920x2/900x24.5x2/4.5x2

9000x3/10000x32.6x3/2.9x3

1750+1000/1700+10008.6+5.4/8.4+5.4

9.82, 2.843.22

860x830x330983x915x425

90/94290058

9000x2+12000/10000x2+130002.6x2+3.5/2.9x2+3.8

1850+1200/1800+11509.0+6.2/8.9+5.9

9.78, 2.833.22

895x655x3451050x720x470

73/77200055

9.84, 2.853.25

2-Compressor Triple Split TypeOne constant-speed compressor drives one indoor

unit,while another constant-speed compressor

drives two indoor units.

COMP

B

COMP

A

A1

B

A2

49

Outdoor Unit Indoor Units