Cours1 Effet Champ
-
Upload
ayoub-ayay -
Category
Documents
-
view
238 -
download
0
description
Transcript of Cours1 Effet Champ
�Effets sur la santédes champs
électromagnétiques basse fréquence
� Jean-louis Lilien (Ulg)� (with informations obtained from L. Verschaeve(VITO), M. De Ridder (RUG), G. Decat(Vito))
unités
� Volt : voltage unity (V)� Ampere : current intensity unity (A)� Tesla, Gauss : magnetic flux density
(1µT=10 mG)� Rms (root mean square) : used in alternative
values. For sinusoïdal shape, rms value equal peak value divided by 1.41
. µ for micro (x 1/1.000.000), ex : µT
� m for milli (x 1/1000) , ex : mV, mA
� k for kilo (x 1000), ex : kV
� M for Mega (x 1.000.000), ex : MHz
� G for Giga (x 1.000.000.000), ex : GHz
Electromagnetic fields
� What is a field ?
� Electric field E (Volt/mètre)
� Magnetic field H (Ampère/mètre)
� Magnetic flux density B (Teslas)
� B shortly named « magnetic field » and expressed in microteslas (µT)
Notion de champs E et B
Champs électromagnétiquesNON ionisants
Extremely low frequency fields
(ELF) =
NON ionising radiation
� Non ionising = energy level such that it is impossible to ionize molecules (in particular living material).
� Typical non-ionizing radiation :
� Power electricity
� Radio waves, infra-red, visible
Natural fields
� Light : with a splendid sensor of electromagnetic field : the eyes,
� Earth magnetic field (30 à 60 µT, direct), lightning (10 µT à 1 km)
� Earth electric field 100 V/m (10 kV/m during thunderstorm, direct)
Natural fields
� Human being : endogenous fields (electro-cardiogram, encephalogram)
� gamma wave(30 à 100 Hz)
� Waves: alpha, beta, theta, delta (3 à 45 Hz)
� Endogenous electric field : 0.1 V/m
No way to disturb human being below 1 mV/m (1% of endogenous field)
Artificial fields
� deliberate : radio emission, TV, GSM (MHz, GHz)
� Non-deliberate : overhead power lines(50 Hz) , railways catenaries, household apparatuses,…
� Example : magnetic field of 10 µT under a 400 kV and electric field of 5 kV/m at ground level, (50 Hz)
� For these two last cases : unknown human sensors, if any.
Un exemple de mesure en continu
� - trajet en tramway : 13.4 µT
� - machine à café : 0.06 µT
� - portique anti-vol dans un centre
commercial : 18.6 µT
� - moyenne au domicile : 0.1 à 0.2 µT + bruit
de fond
Extreme low frequency (ELF) fields
CEM de très faibles fréquences
(<300 kHz)
� Wertheimer & Leeper (1979) � risque de leucémie chez l’enfant
� Énormément de recherches dans tout les domaines (in vitro, in vivo, épidémiologie, etc.)
� ELF champs électriques, ELF champs magnétiques et champs statiques
ELF: CEM de très faibles fréquences
Très faibles énergiesPas d’effets thermiquesChamp magnétique induit des courants électriques dans lecorps
⇒ dosimetrie:
(µ)T plutôt que V/m
Typical E-field under power lines
(400 kV)
Typical magnetic flux density under
HV power lines (400 kV, 2000 A)
B field in Belgium near linesMagnetic fields in the 70 kV network
0
12
3
4
5
6
7
8
-30 -20 -10 0 10 20 30
Distance to the axis of the line (m)
µT
yearly mean 95% rated (0.9 kA)
Magnetic fields in the 150 kV network
0
2
4
6
8
10
12
-50 -25 0 25 50
Distance to the axis of the line (m)
µT
yearly mean 95% rated (1.1 kA)Magnetic fields in the 380 kV network
0
5
10
15
20
25
30
35
40
-80 -60 -40 -20 0 20 40 60 80
Distance to the axis of the line (m)
µT
yearly mean 95%
rated (2.2 kA) max (calculated)
Allure du champ d’induction magnétique B en microteslas
(cas Tihange-Avernas, 150 kV, 1300 A, deux ternes,
SOUTERRAIN)
0
2
4
6
8
10
12
14
-20 -15 -10 -5 0 5 10 15 20
B-f
ield
(µT
)
Distance to the axis of the cables (m)
A
B
Horizontal disposal
A: 150 kV, 1100 AB :70 kV, 450 A
exemples d'exposition aux ELF
champ électrique (tension > 150 kV)• sous le conducteur 1000 - 6000 V/m• à 30 m de l'axe 100 - 2000 V/m• à 100 m de l'axe 10 - 200 V/m
champ magnétiqueTension 0 m 30 m 100m400 kV 30 µT 12 µT 1 µT225 kV 20 µT 3 µT 0,3 µT90 kV 10 µT 1 µT 0,1 µT
télévision à 1 m 0,1 µTperceuse à 30 cm 3 µTmicroordinateur 0,5 µTcouverture élec. 3,5 µT
Allure du champ d’induction magnétique
B en microteslas (résidentiel)
Residential Magnetic field
0,001 0,01 0,1 1 10
Magnetic f ield (µT)
Rel
ativ
e nu
mbe
r of
R
esid
ence
s
ELF (< 300 kHz)
� Peut-on s’attendre à des effets biologiques?
(< 300V/m et <50µT)
Effets biologiques (et nuisibles) donc pas impossibles,Cependant les mécanismes proposés sont peu plausiblesà faibles “doses”
HYPOYHESES:Most cited are:the induction of electrical currents within tissuesfree radical reactionsthe effect of transientsThe creation of a resonance condition on the cell’s surface The presence of small magnetic particles (magnetite ) in animal (including) human tissues resulting in direct magnetic field effects
ELF: effets biologiques?
� Oui, en situations extrêmes: stimulation directe du tissu nerveux ou musculaire qui est possible à partir d’un certain seuil.
� Une exposition faible (normale) peut influencer les tissues biologiques dans certains cas précis (conditions expérimentales). Généralement il n’y a pas d’effets nuisible reconnus.
Effets in vitro?
� Surtout champs magnétiques et expositions
élevées.
-Résultats non concluants
-Peut être le type cellulaire et le mode
d’exposition peuvent-ils être importants?
Études in vivo?
� Études à court et long terme
� Initiation, promotion, cancer
� Les études ne semblent pasdémontrer que les ELFssont cancérigènes (ni initiateur,ni promoteur)
Études in vivo?
Reproduction et développement, immunologie, hématologie, neuroendocrinologie, génétique et autres effets
La conclusion générale est que les CEM (ELF) n’ont pas d’effets biologiques décelables dans ces domaines
Etudes chez l’homme?
� Etudes en laboratoire sur volontaires
mélatonine
Rythme cardiaque
Electrophysiologie et études du sommeil
Effets sur le système immunitaire et les hormones & hypersensibilité
Résultats négatifs, controversés, non concluants
0
10
20
30
40
50
60
10 12 14 16 18 20 22 00 02 04 06 08
70
d'après Selmaoui 1996
mélatonine (pg/ml)
taux de mélatonine nocturne chez l'hommeexposition à un champ de 50 Hz ; 10 µT
heure
champtémoin
Etudes chez l’homme?
� Etudes épidémiologiques
Beperkingen van epi-studies: hoogspanningslijnen en kankerEtudes épidémiologiques:
-résultats controversés - résultats positifs controversés -nombre d’individus limité – (statistiques!)-mesures des champs? Quand? Où? Pendant combien de temps?-controverse entre valeurs mesurées et le ‘wire –code’ -influence d’autres facteurs -mécanisme d’action inconnu
cancérogenèse
agents génotoxiques
erreurs de replication de l'ADN
c. normales c. pré- cancéreuses
agents génotoxiqueserreurs de replication de l'ADN
agents épigénétiques
c. cancéreuse
temps...
agents épigénétiques
cancer
Two models for ALL
Step 1 Initiation
� Prenatally, during fetal development a chromosome translocation resulting in a fusion gene TEL + AML 1
� A clinically silent and covert preleukaemic clone
Step 2 Promotion
� In 1 in 100 : a conversion of the preleukaemic clone to a full blown leukemia
� 2 months – 14 years: an additional postnatal event
Causes of ALL
� As ALL is not a single biological entity or disease (wide variety of subtypes: precursors B-cell and T-cell) it seems highly improbable that its aetiology will be attributable to a single causal mechanism.
� The major causes of childhood cancer are unknown.5 – 15 % : familial and genetic factors5 – 10 % : known exogenous factors
� A risk factor is a specific agent statistically associated with a disease.The weight of evidence can be:� established� suggestive� limited
Suggestive risk factors associated with ALL:
� Maternal fetal loss� Mother older than 35 years at pregnancy, father older then 40 years� Birth weight > 4000 gram (RR = 1.26) (high rate of cell
proliferation)� First born
Limited evidence:� Paternal cigarette smoking before conception and maternal
marijuana use before and during pregnancy� Paternal occupational exposure to hydrocarbons, pesticides� Motor vehicle exhaust gases, pesticides� Postnatal chloramphenicol use� Decreased risk with breastfeeding (RR = 0.76)� 50 Hz magnetic fields > 0,4 µT (RR = 2)
Kroll et al 2006
ALL and influenza epidemics (UK)
ODDS ratio
� L' odds ratio (OR) ou " rapport des cotes " est une autre mesure de la force de l'association entre une exposition et la survenue d'un événement.
� Soit Pt la probabilité d'avoir l'événement dans le groupe traité et Pc la probabilité d'avoir l'événement dans le groupe non exposé.L'odds ratio vaut: OR= [Pt x (1-Pc)]÷ [Pc x (1-Pt)].
� L'odds-ratio est une approximation acceptable du risque relatif lorsque la probabilité de survenue de l'événement est faible (Pt<10%). (le cas des ELF)
méta-analyse leucémies de l ’enfantAhlbom 2000 Br J Cancer – ODDS ratio
< 0,2 µµµµT 0,2 - < 0,4 µµµµT ≥ 0,4 µµµµT
Mesures 1,05 1,14 1,835 études [0,86 - 1,28] [0,85 - 1,53] [1,08 - 3,11]
Calcul 1,58 0,79 2,134 études [0,77 - 3,25] [0,27 - 2,28] [0,93 - 4,88]
Total 1,08 1,10 2,009 études [0,89 - 1,31] [0,83 - 1,47] [1,28 - 3,14]
Exposed children in Belgium (Decat)
> 0.2 µT : 5.7 %> 0.3 µT : 2.7 % RR = 1.7 Greenland> 0.4 µT : 1.3 % RR = 2.0 Ahlbom
If epidemiologic observation would be correct, that would mean an increase of about 1.5 case of ALL leukaemia in Belgium per year.
Typical incidence being about 4 to 5 case/100.000 or 500 cases per year � two of them being potentially induced by ELF
Modelling EMF in living
environment
Measurements of EMF in dynamic environment
Leucémie chez l’enfant
> 0.4 µT IARC
Pas d’autres effetscancer chez l’adulteautres effets chez l’adulteautres effets chez l’enfantpas d’effets des champs statiques(sauf très hautes intensités)
exposition > 0,4 µT
- en Angleterre 0,4 % population
- dans 20 % des cas en raison de lignes HT
IARC classification into 4 groups:
Group 1: The agent (mixture) is carcinogenic to humans. The exposure circumstance entails exposures that are carcinogenic to humans.
Group 2 (two classifications):
Group 2A: The agent (mixture) is probably carcinogenic to humans. The exposure circumstance entails exposures that are probably carcinogenic to humans.
Group 2B: The agent (mixture) is possibly carcinogenic to humans. The exposure circumstance entails exposures that are possibly carcinogenic to humans.
Group 3: The agent (mixture, or exposure circumstance) is unclassifiable as to carcinogenicity in humans.
Group 4: The agent (mixture, exposure circumstance) is probably not carcinogenic to humans.
Agents classified by IARC (834)
� IARC classification
Carcinogenic to humans (75)
(usually based on strong evidence of carcinogenicity in humans)
Probable carcinogenic to humans (59)
(usually based on strong evidence of carcinogenicity in animals)
Possible carcinogenic to humans (225)
(usually based on evidence in humans which is considered credible but for which other explanations could not be ruled out)
� Examples of agents
AsbestosAlcoholic beverages
BenzeneMustard gas
Solar radiationTobacco
X-rays, gamma rays, …
CreosotesDiesel engine exhaust
FormaldehydePCB
Coffee
ELF magnetic fieldsGazoline exhaust
Glass woolPickled vegetables
styrene
Childhood leukemia
in Flanders 1997 - 2001
38 cases/ year (mean over 5 years)75 % : ALL (Europe : 75 – 80 %)Age-standardised incidence rate: 29,8/1.000.000
children < 15 years(Europe: 27,9 – 46,5)
Cumulative risk to develop leukemia before the age of 15 is about 0.05 % (1/2.000)
5 year-survival:84,8 % boys88,1 % girls
Incidence
� High rates in North-West Europe, North America and Oceania
� Lower rates in Asia and Africa� Sharp incidence peak of ALL during childhood has
only been observed in the UK and USA since the 1930’s
� The age peak is absent in many developing or underdeveloped countries, suggesting a leukemogenic contribution from factors associated with industrialisation
� Yearly increase of incidence (0.7 – 1.4 %); now plateau of incidence curve is reached
Health policy must be science based� A single study can form the basis
of an hypothesis, but does not provide the basis for hazard identification.
� Confirmation of the results of any study are needed through replication and/or supportive studies.
� The resulting body of evidence forms the basis for science-based judgments by defining exposure levels for
� adverse health effects and � no observable adverse
effects.
CONCLUSIONS
� Manque de résultats clairs et sans équivoques� Généralement les données sont insuffisantes pour
conclure que les CEM-ELF sont nuisibles. Des effets biologiques ont néanmoins été observés.
� Il existe un lien entre une exposition aux CEM-ELF et la leucémie chez l’enfant (>0.3-0.4µT)
� Les études épidémiologiques ne peuvent s’expliquer par les résultats d’expériences en laboratoire.
� Etudes de répétition nécessaires.
http://www.mcw.edu/gcrc/cop/cell-phone-health-FAQ/toc.html
http://www.icnirp.de/
http://health.fgov.be/CSH_HGR/
http://www.iegmp.org.uk/IEGMPtext.htm
http://www.rsc.ca/english/Rfreport.pdf
http://www.sante.gouv.fr/htm/dossiers/telephon_mobil/index.htm
http://www.who.int
http://www.bbemg.ulg.ac.be/
http://www.greenfacts.org/power-lines/index.htm
http://www.nrpb.org/index.htm