Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L...

5
DESCRIPTION Catalog # Project Comments Prepared by Type Date SPECIFICATION FEATURES PS524013EN 05/20/2019 1 of 5 Corelite ORDERING INFORMATION Sample Number: RZL-NB-50L835-1D-UNV-STD-SWPD1-ILB12-W-SU-28 cover plate (supplied) supports the fixture at the power mount and connects to a 4” octagonal junction box, by others. All other mounts interface to 1/4”-20 studs, by others, protruding from the ceiling. Mounting centers for the first fixture is the length of the fixture less 2-3/8” , all other mounting centers are 4’, 8’ or 12’ on- center. Refer to installation instructions for more details. All sections are continuously wired with snap quick connects for fast installation. Fixtures can be joined via internal joining brackets for rigid, straight continuous runs. Finish Electrostatically applied polyester powder coat paint in white, silver, or black. RAL custom colors are available. Injection molded components are color matched. Construction Compact 3.5”x 6.4” profile with a die- formed 20 gauge cold rolled steel upper channel for strength and rigidity combined with a die-formed aluminum lower housing. Driver accessible from below by removing gear tray assembly. End Caps & Joining Covers End caps and joiner covers are injection molded polycarbonate, mechanically attached with no fasteners. Light Engine LED’s are available in 3000K, 3500K or 4000K with CRI options of either ≥80CRI or ≥90CRI. Lumen output will be affected - please refer to the lumen adjustment factor table. Electrical Long-Life LED system coupled with integral electronic drivers to deliver 3.5" [89 mm] 6.4" [163 mm] 3.5" [89 mm] 6.4" [163 mm] Series Shielding/Optics Lumen Package Nominal per 4’ section CRI / Color Temperature Circuiting Specialty Wiring Input Voltage RZL = RZL Linear LED NL = Frosted Linear Prismatic Lens (100% Down) NB = Micro Baffles / Prismatic Lens (100% Down) WL = Luminous Sides, Frosted Linear Prismatic Lens WB = Luminous Sides, Micro Baffles / Prismatic Lens WF = Metal Baffles with Perf Siderails / Smooth Frosted Lens 30L = 3,000 Lms (750 lms/ft) 40L = 4,000 Lms (1,000 lms/ft) 50L = 5,000 Lms (1,250 lms/ft) 65L = 6,500 Lms (1,625 lms/ft) 80L = 8,000 Lms (2,000 lms/ft) 830 = LED 3000K, 80 CRI 835 = LED 3500K, 80 CRI 840 = LED 4000K, 80 CRI 930 = LED 3000K, 90 CRI 935 = LED 3500K, 90 CRI 940 = LED 4000K, 90 CRI 1 = 1 Circuit D = None E = Emergency Circuit S = Secondary Circuit N = Emergency + Secondary Circuit UNV = Universal (120V-277V) 347 = 347V Nominal lumen values baselined on WB version. Refer to performance table on Page 3 for more detail. Consult factory for custom lumen outputs. Additional lead-time may apply for 930, 935 and 940 configurations. Refers to wiring in cross section. Emergency and Secondary circuit section wiring are configured per 4ft section. Secondary circuit not available with integrated sensor options. Integral 347V driver with STD 0-10V option only. Factory supplied 347V remote transformer for all other driver options. Driver/Dimming Options Integrated Sensor Integral Emergency Finish Mounting Run Length STD = Standard 0-10V (1%-100%) 5LT = Fifth Light DALI (5%-100%) LH = Lutron HiLume 1% EcoSystems L5 = Lutron 5-Series 5% EcoSystems SWPD1 = WaveLinx Wireless Integrated Sensor LWIPD1 = LumaWatt Pro Wireless Integrated Sensor SVPD1 = 0-10V Stand-alone Integrated Sensor ILB12 = 12-watt battery pack, 120V-277V, Iota ILB-SL-CP12 EPC = UL924 Bypass Relay W = White S = Silver B = Black CC = Custom Color SU = Ceiling Surface Mount, Junction Box 4 = 4 ft. 8 = 8 ft. 12 = 12 ft. XX = Specify Row Length Must be used with “STD” driver. Integrated Sensors combined with Emergency Circuit require one UL924 Bypass Relay per emergency section. Refer to Mounting on Page 1 and installation instructions for more details. Standard row configurations over 12’ consist of 8’ and 12’ luminaires. RZL LED Surface Direct / Semi-Direct The RZL is a suspended and surface mount linear direct and semi-direct LED continuous row solution for new and retrofit construction. Designed for larger open ceiling environments, the RZL offers advanced LED technology and optical distributions that deliver high quality soft diffuse illumination while minimizing installation costs with the ability to mount continuously with 4, 8 and 12 foot modular sections. The wide variety of styles and lumen outputs available make it easy to use in a variety of building environments including aisleways, retail, educational facilities, open offices, and low bay applications. cULus – 1598 Damp Location Listed LM79/LM80 Compliant ROHS Compliant DesignLights Consortium® Qualified optimal performance. Standard with 120-277V 0-10V dimming drivers (1% standard). 347V 0-10V drivers are available. Dimming wires come standard but can be capped in the field for standard switched operation. A single power feed drop supplied as standard. Controls Options compatible with Cooper Lighting Solutions' Connected Lighting Systems: • WaveLinx sensor • LumaWatt Pro sensor • Fifth Light DALI driver Refer to the Connected Lighting options page and ordering information for more details. Mounting Surface mount – custom junction box

Transcript of Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L...

Page 1: Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L 8078 2020 75 18.7 108 RZL-WF 30L 3045 761 25 6.2 123 40L 4036 1009 35 8.7 116 50L

DESCRIPTION

Catalog #

Project

Comments

Prepared by

Type

Date

SPECIFICATION FEATURES

PS524013EN05/20/2019

1 of 5

Corelite

ORDERING INFORMATION

Sample Number: RZL-NB-50L835-1D-UNV-STD-SWPD1-ILB12-W-SU-28

cover plate (supplied) supports the fixture at the power mount and connects to a 4” octagonal junction box, by others. All other mounts interface to 1/4”-20 studs, by others, protruding from the ceiling. Mounting centers for the first fixture is the length of the fixture less 2-3/8”, all other mounting centers are 4’, 8’ or 12’ on-center. Refer to installation instructions for more details. All sections are continuously wired with snap quick connects for fast installation. Fixtures can be joined via internal joining brackets for rigid, straight continuous runs.

FinishElectrostatically applied polyester powder coat paint in white, silver, or black. RAL custom colors are available. Injection molded components are color matched.

ConstructionCompact 3.5”x 6.4” profile with a die- formed 20 gauge cold rolled steel upper channel for strength and rigidity combined with a die-formed aluminum lower housing. Driver accessible from below by removing gear tray assembly.

End Caps & Joining CoversEnd caps and joiner covers are injection molded polycarbonate, mechanically attached with no fasteners.

Light Engine LED’s are available in 3000K, 3500K or 4000K with CRI options of either ≥80CRI or ≥90CRI. Lumen output will be affected - please refer to the lumen adjustment factor table.

ElectricalLong-Life LED system coupled with integral electronic drivers to deliver

3.5"[89 mm]

6.4" [163 mm]

3.5"[89 mm]

6.4" [163 mm]

Series Shielding/OpticsLumen Package

Nominal per 4’ sectionCRI / Color

TemperatureCircuiting Specialty Wiring Input Voltage

RZL = RZL Linear LED

NL = Frosted Linear Prismatic Lens (100% Down)NB = Micro Baffles / Prismatic Lens (100% Down)WL = Luminous Sides, Frosted Linear Prismatic LensWB = Luminous Sides, Micro Baffles / Prismatic LensWF = Metal Baffles with Perf Siderails / Smooth

Frosted Lens

30L = 3,000 Lms (750 lms/ft)40L = 4,000 Lms (1,000 lms/ft)50L = 5,000 Lms (1,250 lms/ft)65L = 6,500 Lms (1,625 lms/ft)80L = 8,000 Lms (2,000 lms/ft)

830 = LED 3000K, 80 CRI835 = LED 3500K, 80 CRI840 = LED 4000K, 80 CRI930 = LED 3000K, 90 CRI935 = LED 3500K, 90 CRI940 = LED 4000K, 90 CRI

1 = 1 Circuit D = None E = Emergency CircuitS = Secondary CircuitN = Emergency +

Secondary Circuit

UNV = Universal (120V-277V)

347 = 347V

Nominal lumen values baselined on WB version. Refer to performance table on Page 3 for more detail. Consult factory for custom lumen outputs.

Additional lead-time may apply for 930, 935 and 940 configurations.

Refers to wiring in cross section.

Emergency and Secondary circuit section wiring are configured per 4ft section. Secondary circuit not available with integrated sensor options.

Integral 347V driver with STD 0-10V option only. Factory supplied 347V remote transformer for all other driver options.

Driver/Dimming Options Integrated Sensor Integral Emergency Finish Mounting Run Length

STD = Standard 0-10V (1%-100%)5LT = Fifth Light DALI (5%-100%)LH = Lutron HiLume 1% EcoSystemsL5 = Lutron 5-Series 5% EcoSystems

SWPD1 = WaveLinx Wireless Integrated Sensor

LWIPD1 = LumaWatt Pro Wireless Integrated Sensor

SVPD1 = 0-10V Stand-alone Integrated Sensor

ILB12 = 12-watt battery pack, 120V-277V, Iota ILB-SL-CP12

EPC = UL924 Bypass Relay

W = WhiteS = SilverB = BlackCC = Custom Color

SU = Ceiling Surface Mount, Junction Box 4 = 4 ft. 8 = 8 ft.12 = 12 ft.XX = Specify Row Length

Must be used with “STD” driver.Integrated Sensors combined with Emergency Circuit require one UL924 Bypass Relay per emergency section.

Refer to Mounting on Page 1 and installation instructions for more details.

Standard row configurations over 12’ consist of 8’ and 12’ luminaires.

RZLLED

SurfaceDirect / Semi-Direct

The RZL is a suspended and surface mount linear direct and semi-direct LED continuous row solution for new and retrofit construction. Designed for larger open ceiling environments, the RZL offers advanced LED technology and optical distributions that deliver high quality soft diffuse illumination while minimizing installation costs with the ability to mount continuously with 4, 8 and 12 foot modular sections. The wide variety of styles and lumen outputs available make it easy to use in a variety of building environments including aisleways, retail, educational facilities, open offices, and low bay applications.

cULus – 1598Damp Location Listed

LM79/LM80 CompliantROHS Compliant

DesignLights Consortium® Qualified

optimal performance. Standard with 120-277V 0-10V dimming drivers (1% standard). 347V 0-10V drivers are available. Dimming wires come standard but can be capped in the field for standard switched operation. A single power feed drop supplied as standard.

ControlsOptions compatible with Cooper Lighting Solutions' Connected Lighting Systems: • WaveLinx sensor • LumaWatt Pro sensor • Fifth Light DALI driver Refer to the Connected Lighting options page and ordering information for more details.

MountingSurface mount – custom junction box

Page 2: Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L 8078 2020 75 18.7 108 RZL-WF 30L 3045 761 25 6.2 123 40L 4036 1009 35 8.7 116 50L

PS524013EN05/20/2019

2 of 5

RZL LINEAR SUSPENDED SPECIFICATION FEATURES CONTINUED

SHIELDING OPTIONS

Fixture Lengths

48" [1219 mm]

96" [2483 mm]

144" [3658 mm]

NL NB WL WB WF

with 0.0625”stagger hole spacing for side visual brightness. Smooth curved frosted acrylic center lens to eliminate direct view of the LEDs from below. Shielding assembly swings down for access to LEDs.

Lumen MaintenanceProjected lumen maintenance based on TM-21 standards is L85 > 60,000 hours at 25°C ambient conditions.

Emergency OptionsOptional 120V-277V integral emergency battery pack is 12W maximum, 90 minute output, and powers a 4-foot section. Test switch/indicator button located on the endcap or joiner cover. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 12 = 1200 lumens). The combination of integrated sensor and emergency circuit options require an EPC UL924 bypass relay that disables sensor control of emergency sections when normal power is lost.

Integrated Sensing and Control SystemsIntegrated options must be used in conjunction with

the associated system and may not be compatible with other options or accessories. Please consult WaveLinx and LumaWatt Pro system pages for additional details and compatibility. Consult Marketplace Options - Lutron system pages for additional details and compatibility. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com.

Weight4.0 - 4.5 lbs per foot.

ComplianceModules are UL recognized components and indoor luminaires are cULus listed for 25°C ambient environments, damp location listed, and RoHS compliant. LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium® Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details.

WarrantyFive year warranty.

LengthsAvailable in 4-ft, 8-ft, and 12-ft sections. All sections are modular eliminating the need for starter, joiner and end sections. Standard row configurations over 12-ft consist of 8-ft and 12-ft luminaires unless otherwise specified.

ShieldingNL: Solid aluminum sides with frosted linear prismatic lay-in flat acrylic lens, 0.125” thick. No uplight.

NB: Solid aluminum sides with high transmission 0.125” thick clear linear prismatic lay-in flat acrylic lens with white micro baffle inlay to minimize visual glare. No uplight.

WB: Snap-on three-sided high transmission 0.125” thick clear linear prismatic acrylic lens with white micro baffle inlay to minimize visual glare.

WL: Snap-on three-sided frosted linear prismatic acrylic lens, 0.125 inches thick.

WF: Die-formed aluminum baffle assembly (4” blade spacing). Perforated siderail sections are 23% open

Page 3: Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L 8078 2020 75 18.7 108 RZL-WF 30L 3045 761 25 6.2 123 40L 4036 1009 35 8.7 116 50L

PS524013EN05/20/2019

3 of 5

RZL LINEAR SUSPENDED

ENERGY AND PERFORMANCE DATA LUMEN ADJUSTMENT FACTORS

LUMEN MAINTENANCE

SENSOR INTEGRATION JOINING

Integrated sensors are located in the joint of 8’ and 12’ units and in the endcap of 4’ units for individual and continuous runs. Each unit can be individually controllable or grouped together with the integrated sensors.

Fixtures are seamlessly connected together with an internal joining sleeve that provides rigidity and durability for long product runs. Simply attach the joining sleeve on one side, slide the next fixture over the joining sleeve and mechanical fasten with two screws on each side. Decorative cover plate snaps over joint to conceal all hardware.

3.5"[89 mm]

6.4" [163 mm]

OTHER VIEWS

RZL-WF Cross Section

Ambient Temperature

TM-21 Lumen Maintenance

(60,000 hours)

Theoretical L70

(Hours)

25°C >85% 131,000

RZL LED Performance (3500K/80CRI)

Series/ Distribution

Lumen Package

Delivered Lumens Wattage Efficacy LPW4FT Per FT 4FT Per FT

RZL-NL

30L 3111 778 25 6.2 126

40L 4123 1031 35 8.7 119

50L 5219 1305 41 10.2 128

65L 6807 1702 57 14.1 120

80L 8359 2090 75 18.7 112

RZL-NB

30L 2871 718 25 6.2 116

40L 3805 951 35 8.7 110

50L 4816 1204 41 10.2 118

65L 6282 1571 57 14.1 111

80L 7714 1929 75 18.7 103

RZL-WL

30L 3286 822 25 6.2 133

40L 4355 1089 35 8.7 125

50L 5512 1378 41 10.2 135

65L 7190 1798 57 14.1 127

80L 8829 2207 75 18.7 118

RZL-WB

30L 3007 752 25 6.2 121

40L 3985 996 35 8.7 115

50L 5043 1261 41 10.2 123

65L 6579 1645 57 14.1 116

80L 8078 2020 75 18.7 108

RZL-WF

30L 3045 761 25 6.2 123

40L 4036 1009 35 8.7 116

50L 5108 1277 41 10.2 125

65L 6662 1666 57 14.1 118

80L 8181 2045 75 18.7 109

Example Calculation:RZL-NB / 40L / 3500K / 80 CRILumen Output selected = 951 lms/ft

3500K / 90 CRI DesiredLumen Adjustment Factor = 0.861

Adjusted Lumen Output = 951 lms/ft x 0.861 = 819 lms/ft

CCT 80 CRI 90 CRI

3000K 0.967 0.830

3500K 1.000 0.861

4000K 1.024 0.883

COLOR DATA (3500K)

80CRI

TM-30-15Rf 82.6

Rg 94.9

CRI/CIERa 83.6

R9 25.0

Page 4: Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L 8078 2020 75 18.7 108 RZL-WF 30L 3045 761 25 6.2 123 40L 4036 1009 35 8.7 116 50L

PS524013EN05/20/2019

4 of 5

RZL LINEAR SUSPENDED PHOTOMETRICS

Zone Lumens%

FixtureVertical Angle 0º 45º 90º

0º-30º 1472 30.6 45º 7526 8726 10263

0º-90º 4816 100 55º 6254 7798 8721

90º-130º 0 0.0 65º 4817 5897 7430

90º-180º 0 0.0 75º 3563 4514 6243

0º-180º 4816 100 85º 1569 2511 3458

Zone Lumens%

FixtureVertical Angle 0º 45º 90º

0º-30º 1517 29.1 45º 8933 9191 9347

0º-90º 5219 100 55º 7942 8323 8563

90º-130º 0 0 65º 6761 7301 7712

90º-180º 0 0 75º 5467 6138 6701

0º-180º 5219 100 85º 3977 4816 52390º

90º90º

ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M2)FILE NAME: RZL-NL-50L835-UNV-4.IES

CCT: (LD4) LED 3500K

LUMENS: 5219 Lm

WATTS: 40.9 W

EFFICACY: 128 Lm/W

TEST NO.: P189015

165°

135°

105°491

981

1472

1963

120°

150°

180°

0

491

981

1472

19630°

30°

60°

90°

15°

45°

75°

0º 90º

90º

ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M2)FILE NAME: RZL-NB-50L835-UNV-4.IES

CCT: (LD4) LED 3500K

LUMENS: 4816 Lm

WATTS: 40.9 W

EFFICACY: 118 Lm/W

TEST NO.: P189000

165°

135°

105°485

970

1455

1940

120°

150°

180°

0

485

970

1455

19400°

30°

60°

90°

15°

45°

75°

0º 90º

90º

ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M2)FILE NAME: RZL-WL-50L835-UNV-4.IES

CCT: (LD4) LED 3500K

LUMENS: 5512 Lm

WATTS: 40.9 W

EFFICACY: 135 Lm/W

TEST NO.: P189045

165°

135°

105°452

904

1357

1809

120°

150°

180°

0

452

904

1357

18090°

30°

60°

90°

15°

45°

75°

0º 90º

90º

ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M2)FILE NAME: RZL-WB-50L835-UNV-4.IES

CCT: (LD4) LED 3500K

LUMENS: 5043 Lm

WATTS: 40.9 W

EFFICACY: 123 Lm/W

TEST NO.: P189030

165°

135°

105°431

862

1293

1723

120°

150°

180°

0

431

862

1293

17230°

30°

60°

90°

15°

45°

75°

Zone Lumens%

FixtureVertical Angle 0º 45º 90º

0º-30º 1382 25.1 45º 7766 6908 6758

0º-90º 4933 89.5 55º 6784 5931 5916

90º-130º 445 8.1 65º 5694 4906 5234

90º-180º 579 10.5 75º 4530 4016 4798

0º-180º 5512 100 85º 2976 3283 4641

Zone Lumens%

FixtureVertical Angle 0º 45º 90º

0º-30º 1287 25.5 45º 6289 5995 6401

0º-90º 4427 87.8 55 5293 5077 5593

90º-130º 474 9.4 65º 4402 4244 5017

90º-180º 616 12.2 75º 3522 3621 4647

0º-180º 5043 100 85º 2519 3251 466912% UP / 88% DOWN

0º 90º

90º

ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M2)FILE NAME: RZL-WF-50L835-UNV-4.IES

CCT: (LD4) LED 3500K

LUMENS: 5108 Lm

WATTS: 40.9 W

EFFICACY: 125 Lm/W

TEST NO.: P189060

165°

135°

105°500

1000

1501

2001

120°

150°

180°

0

500

1000

1501

20010°

30°

60°

90°

15°

45°

75°

Zone Lumens%

FixtureVertical Angle 0º 45º 90º

0º-30º 1513 29.6 45º 8407 9107 10013

0º-90º 5108 100 55 7538 8385 9279

90º-130º 0 0 65º 6524 7239 7347

90º-180º 0 0 75º 5026 5203 4353

0º-180º 5108 100 85º 3362 3470 3887100% DOWN

10% UP / 90% DOWN

100% DOWN

100% DOWN

Page 5: Corelite RZL Surface LED - Cooper Lighting...50L 5043 1261 41 10.2 123 65L 6579 1645 57 14.1 116 80L 8078 2020 75 18.7 108 RZL-WF 30L 3045 761 25 6.2 123 40L 4036 1009 35 8.7 116 50L

PS524013EN05/20/2019

5 of 5

RZL LINEAR SUSPENDED SVPD1 INTEGRATED SENSOR

The RZL with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The RZL delivers superior lighting with integrated PIR occupancy sensing and daylighting controls.

Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the RZL delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied.

The integral daylight sensors reduce the need for special daylight zone planning. The luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.

Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.

The RZL with Integrated Sensors is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.

Coverage

Optional RemoteControls

ISHH-01 Programming Remote ISHH-02 Personal Control Remote

CL

Top View Side View

4m[12 ft.]

4m[12 ft.]

0m[0 ft.]

Coverage

Major Motion

3.3m[10 ft.]

0m[0 ft.]

0m[0 ft.]

4m[12 ft.]

4m[12 ft.]

Recommended Mounting Height 8–12 ft.

100

0

Lig

ht

Leve

l (DO)Daylight Level

(DO)Daylight Level

Timeout Value

(ES)Energy SaverLight Level

OccupiedUnoccupiedOccupiedUnoccupied

Energy SavingsOpportunities

(DU)Unoccupied Level

Target light level default: 500 lux at 8 ft.

Programming Remote

ISHH-01

To Set Output

1. Raise, Lower or Press Min.

50, 75, Max.

2. To save press SET

3. Select Occ or Un Occ

Raise/Lower

TimeOut5

10

15

20

HI

LO

ES

SET

Occ

50

MIN

UnOcc

MAX

75

Personal Remote

ISHH-02

Raise/Lower

SCENEMAX

75

50

MIN

UnOcc

ES

OccTo Select Scenes

Press the SCENE button.

The lighting will adjust to

stored light levels..

How it works:

• When a user enters under an integral sensor, the luminaire controlled by that sensor turns ON to the daylight level (default 500 lux).

• Lighting will remain at the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).

• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level (defaultmatches occupied daylight level). This adjustable light level is often set to half of the occupied daylight level.

• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.