Transcript of Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?
![Page 1: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/1.jpg)
copyright Mestek, Inc. 2006
![Page 2: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/2.jpg)
What’s High VelocityWhat’s High Velocity
Air Conditioning?Air Conditioning?
![Page 3: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/3.jpg)
High Velocity SystemsHigh Velocity Systems• A central, split system… •not a window shaker, or a mini-
split• Unique air handler and duct
system • Uses aspiration and blending not
air change• Roughly half the CFM of
conventional systems•5 ton unit is 1150 CFM•Average 250 CFM/Ton
![Page 4: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/4.jpg)
What is Small Duct High What is Small Duct High Velocity Air Conditioning?Velocity Air Conditioning?
• SDHV indicates a blower & indoor coil combination that:
• Is designed for, and produces, at least 1.2 inches of external static pressure when operated at the certified air volume rate of 220-350 CFM per rated ton of cooling; and…..
• when applied in the field, uses high velocity room outlets generally greater than 1000 fpm which have less than 6.0 square inches of free area.
-- ARI/DOE definition
![Page 5: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/5.jpg)
• Diffusion and throw.
• Air change.
• Duct placement works for heating OR cooling, NOT BOTH.
Conventional ACConventional AC
![Page 6: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/6.jpg)
• Less air volume
• Greater ∆T & ∆P
• Circulates room air
• Condenses more water vapor
Hi-Velocity AspirationHi-Velocity Aspiration
![Page 7: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/7.jpg)
Central ReturnCentral Return
• Air mixing vs. Air change
• Less return air volume
• Cooling by temperature,
not volume
![Page 8: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/8.jpg)
Sensible vs LatentSensible vs Latent• “Dry Bulb”
• Measured with thermometer
• Windows, insulation, solar gain
• “Wet Bulb”
• Measurement with Sling
Psychrometer
• People, cooking, etc.
• Important to comfort
•Infiltration
![Page 9: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/9.jpg)
Sensible/Latent ComfortSensible/Latent Comfort• Temperature and evaporation
• Cold and clammy
• Hot and dry
• High efficiency conventional - thin coil
• Spacepak - 6 row thick coil
• Psychrometric chart graphically explains
![Page 10: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/10.jpg)
PsychrometricPsychrometricChartChart
MorePsychrometrics
![Page 11: Copyright Mestek, Inc. 2006. What’s High Velocity Air Conditioning?](https://reader033.fdocuments.net/reader033/viewer/2022042703/56649e2d5503460f94b1c736/html5/thumbnails/11.jpg)
11 SEER Minimum11 SEER Minimum
• D.O.E. has raised the the minimum efficiency for
Spacepak from 10 to 11
• Space Pak currently has more mix & match
combinations that meet or exceed 11 SEER
requirement than any other high velocity
manufacturer