112007NOV152007NOV15NEC ConfidentialNEC Confidential
PASOLINK NEO & NEO/cRoadmap & Product Line Up
For Banglalink
-
5/26/2018 Copy of Paso Neo Presentation
2/49
222007NOV152007NOV15NEC ConfidentialNEC Confidential
Equipment Menu (PASOLINK NEO)Equipment Menu (PASOLINK NEO)
Modulation256QAM
128QAM
64QAM
32QAM
16QAM
8PSK
4PSK
0 3.5 7.0 14.0 28.0 40.0 56.0 [MHz]
Adjacent CH Spacing
5E1 10E1 20E1
5E1 10E1 20E1 40E1
100MB/48E1
STM-1
PASOLINK NEO
(Standard version)
-
5/26/2018 Copy of Paso Neo Presentation
3/49
332007NOV152007NOV15NEC ConfidentialNEC Confidential
1.1. EquipmentEquipment MenuMenu
Interface (NEO)
PDH : 5/10/20E1, 4PSK
5/10/20/32/40E1, 16QAM
48E1, 32QAM
1/2E3, 4PSK/16QAM
SDH : STM-1, 128QAM
2xSTM-1, 128QAM/XPIC
Ethernet : 10M/20M/40Mbps, 4PSK
10M/20M/40M/80Mbps, 16QAM
100Mbps, 32QAM
100M/50M or 75M/75Mbps, 128QAM
RF Frequency
NEO : L6/U6/7/8/10.5/11/13/15/18/23/26/28/32/38/52GHz
2x40E1=>80E12x48E1=>96E1
PDH XPIC
-
5/26/2018 Copy of Paso Neo Presentation
4/49442007NOV152007NOV15NEC ConfidentialNEC Confidential
PASOLINK NEO IDU MODULESPASOLINK NEO IDU MODULES
1
2
3
4 5
7
6
PASOLINK NEO IDU RACK AND MODULES
NO.
1
2
3
3
4
4 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Main Slot
4 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Main Slot
4 H2965 [C] LAN / WS INTFC SDH Main Slot (2 Port LAN)
5 H2965 [C] LAN / WS INTFC SDH Main / Sub-Slot (WS/SC LAN)
4 H3021 GbE INTFC SDH Main Slot
5 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Sub-Slot (APS)
5 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Sub-Slot (APS)
5 H2965 [A] LAN / WS INTFC SDH Sub-Slot (WS/SC LAN)
6 H2980 [B] 16E1 E/W 2 Way DXC INTFC PDH With 2 Port LAN
5 H2965 [B] LAN / WS INTFC SDH Sub-Slot (WS)
6
6
6 H3010 E3 INTFC PDH Two E3, up to 8 WS
6 H3020 4P LAN INTFC PDH With E1s
7
CODE NO. MODULE NAME REMARKS
H2931 RACK COMMON
H2940 MODEM COMMON (1+0)
H2940 MODEM COMMON (1+1)
H3040 DC-DC CONV COMMON (1+0) (with EHG ODU)
H2960 [A] STM-1 INTFC Electrical SDH Main Slot
H2980 [A] 16E1 INTFC + 2 Port LAN PDH
H3000 48E1 INTFC PDH
H2950 CTRL COMMON
-
5/26/2018 Copy of Paso Neo Presentation
5/49552007NOV152007NOV15
NEC ConfidentialNEC Confidential
Replaceable Interface Cards
Interface cards
Control CardModem
-
5/26/2018 Copy of Paso Neo Presentation
6/49662007NOV152007NOV15
NEC ConfidentialNEC Confidential
Replaceable Interface Cards
1. 16E1 + 2 Port LAN
5. 1xE3/2xE3 + 2port LAN
2. 48E1
3. 4 Port LAN + 4/8E1
4. 32E1 + 2 Port LAN
6. STM-1(opt)
7. STM-1(elec)
8. 2 Port LAN or WS(E1)/LAN
9. 1 Port GbE
10. 16E1+2 Port LAN with DXC
11. Nodal (expandable)
12. Nodal (expandable: STM-1 termination)
13. VLAN (4port FE+4E1)
14. VLAN (3port FE+1port GbE+1E1)
[NEO Standard]
[VLAN][Standard Nodal]
Just released
2008 1Qust released
-
5/26/2018 Copy of Paso Neo Presentation
7/49772007NOV152007NOV15
NEC ConfidentialNEC Confidential
32E1 & 2PORT LAN INTFC FOR PDH
80/96E1 PDH XPIC SYSTEM
-
5/26/2018 Copy of Paso Neo Presentation
8/49
882007NOV152007NOV15NEC ConfidentialNEC Confidential
32E1 + LAN32E1 + LAN
E1 x 32 Channels (MDR68(68pin) x 2, 75/120 ohm S/W selectable)
10/100BASE-T(X) x 2 Ports (RJ-45 x 2, Auto-Negotiation / Auto-MDI/MDIX)
System : PDH
N/AN/AO
E1 Protection (SNCP)2Way DXCTERMINAL
Transmission Capacity & Modulation
10M 20M 40M 80M 100M 156M
QPSK/16QAM 16QAM 32QAM 128QAM
O O O O O N/A
Mapping Interface Speed
MAIN SC 10M 100M 1000MRMON
O O O O N/A O N/A
VLAN
LAN Specification
.
-
5/26/2018 Copy of Paso Neo Presentation
9/49
992007NOV152007NOV15NEC ConfidentialNEC Confidential
PDH XPIC (CCDP)PDH XPIC (CCDP)
FeaturesFeaturesSuper PDH
80E1/ 16QAM in 28MHz band width
96E1/ 32QAM in 28MHz band width
Good XPIF (Cross Polarize Interference Improvement Factor)
16QAM 15 dB (1dB degradation C/I 25dB
-
5/26/2018 Copy of Paso Neo Presentation
10/49
10102007NOV152007NOV15NEC ConfidentialNEC Confidential
XPIC ConfigurationXPIC Configuration
Two ODUs and Dual polarized Antenna
Vertical
Horizontal Cancel and Control signals
40/48E1
28 MHz
Vertical(11-38GHz Direct Mount Antenna Available.
6-10GHz feeder connect ion between Antenna
and ODU)Horizontal
Two IDUs 40/48E1
-
5/26/2018 Copy of Paso Neo Presentation
11/49
11112007NOV152007NOV15NEC ConfidentialNEC Confidential
80/96E1 PDH XPIC System80/96E1 PDH XPIC System
1+0 IDU40/48E1 ODU
f1
ODU
f1
1+0 IDU40/48E1
V
H
1+0 IDU40/48E1ODU
f1
ODU
f1
1+0 IDU40/48E1
VH
HV
-H
-V
V
H
V
H
Cancellation
XPIC System configuration
TX SIDE RX SIDE
40E1/16QAM or 48E1/32QAM40E1/16QAM or 48E1/32QAM
28MHz
40/48E1
40/48E128MHz
40/48E1
IDU ODU
40/48E1
40/48E1
40/48E1
PDH XPIC S t P tPDH XPIC S t P t
-
5/26/2018 Copy of Paso Neo Presentation
12/49
12122007NOV152007NOV15NEC ConfidentialNEC Confidential
PDH XPIC System ParameterPDH XPIC System Parameter
System parameters are the same as normal equipment
Frequency band 6-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHz
Range(GHz) 5.925-8.5 10.15-11.7 12.75-13.25 14.2-15.35 17.7-19.7 21.2-23.6 24.25-27.0 27.5-29.5 31.8-33.4 37.0-40.0
Tx pow er(dBm)
32QAM 25 21 21 21 19 19 18 18 17 14.5
16QAM 26 21.5 22.5 22.5 22 22 20 18 17 14.5
Receive r thre shold(dBm ) at 10-6 BER
100M/32Q -75.5 -74.5 -74.5 -75.0 -75.0 -75.0 -74.5 -74.5 -73.0 -73.0
80M/16Q -77.0 -76.0 -76.0 -76.5 -76.5 -76.5 -76.0 -76.0 -74.5 -74.5
System Gain(dB) at 10-6 BER
100M/32Q 100.5 95.5 95.5 96.0 94.0 94.0 92.5 92.5 90.0 87.5
80M/16Q 103.0 97.5 98.5 99.0 98.5 98.5 96.0 94.0 91.5 89.0
Regarding QPSK, CCDP can be applied without XPIC.
NEO/
-
5/26/2018 Copy of Paso Neo Presentation
13/49
13132007NOV152007NOV15NEC ConfidentialNEC Confidential
NEO/c
Main FeaturesMain Features
Common platform design (PDH, LAN)
16E1 + 2FE INTFC Card
Bitrate Free10MB/ 20MB/ 40MB (Same Module)
Modulation Selectable
4PSK/ 16QAM
Compact size/ Low power
IDU :1+0/1+1 @ 1U without FAN , ODU : 2 LTR(13G~)
Bandwidth and Modulation Free ODU
Coverage from 5E1 to 16E1 or from 10M to 40Mbps.
-
5/26/2018 Copy of Paso Neo Presentation
14/49
14142007NOV152007NOV15NEC ConfidentialNEC Confidential
1+0 Equipment Configuration1+0 Equipment Configuration
ODU(13G-38G)
CTRL
1U
IDU Dim. :482x44x190mm
vs PASO V4 : 76%
vs NEO standard : 84%
IDU E1 Interface
ALM INTFC (Opt ion)
DC -48VSC/ALM
Fuse (same as V4/PASO+)
LCT
1+0 @ 1U
Bitrate free (5E1 16E1)
Modulation free (4PSK, 16QAM)
ODU(7G/8G)
1+1 Equipment Configuration1+1 Equipment Configuration
-
5/26/2018 Copy of Paso Neo Presentation
15/49
15152007NOV152007NOV15NEC ConfidentialNEC Confidential
1+1 Equipment Configuration1+1 Equipment Configuration
INTFC Card 16E1 INTFC only
MD UNIT (for NEO/c)CTRL Card (for NEO/c)
1U
ODU / Hybrid
IDU
IDU Dim.482x44x230mm1+0 exp / 1+1 @ 1U
Bitrate free (5E1 16E1)
Modulation free (4PSK, 16QAM)
same as NEO standard
vs PASO V4 : 92%
NEO/c IDU MenuNEO/c IDU Menu
-
5/26/2018 Copy of Paso Neo Presentation
16/49
16162007NOV152007NOV15NEC ConfidentialNEC Confidential
NEO/c IDU MenuNEO/c IDU Menu
Type System
Config.
Capacity Modulation LAN Form
1-1 1+0 5xE1 Fix 4PSK Fix N/A
1-2 1+0 5/10/16 xE1
Selectable
4PSK Fix N/A
1-3 1+0 5/10/16 xE1
Selectable
4PSK/16QAM
Selectable
N/A
2-1 1+1
/1+0 exp.
5/10/16 xE1
Selectable
4PSK Fix Up to
40MB
2-2 1+1
/1+0 exp.
5/10/16 xE1
Selectable
4PSK/16QAM
Selectable
Up to
40MB
*1) e/w Alarm Interface Option
*1)
*1)
*1)
ODU Menu (Comparison with V4/Mx)ODU Menu (Comparison with V4/Mx)
-
5/26/2018 Copy of Paso Neo Presentation
17/49
17172007NOV152007NOV15NEC ConfidentialNEC Confidential
ODU Menu (Comparison with V4/Mx)ODU Menu (Comparison with V4/Mx)
o:released -:N/A
Current Menu L6 U6 7 8 10 10.5 11 13 15 18 23 26 28 32 38 52
- - - - - - -
- - - - - - - -
New Menu
- - - - - - - -NEO/c
Mx
NEO standard
V4
7G/8G 13G -- 38G
SUB Band :same as V4 ODU
Application of NEO standard/compactApplication of NEO standard/compact
-
5/26/2018 Copy of Paso Neo Presentation
18/49
18182007NOV152007NOV15NEC ConfidentialNEC Confidential
Application of NEO standard/compactApplication of NEO standard/compact
NEO/cNEO/c
NEO standardNEO standard5E1-16E1
4PSK/16QAM
5E1-48E1 / STM-1 (XPIC)
4PSK-128QAM
Fixed Upgrade
with LAN NEO standardODU
1+1,1+0 exp.
NEO compact
For future upgrade
without LAN
NEO standard IDU
1+1,1+0 exp.
1+0 fixed
NEO compact
-
5/26/2018 Copy of Paso Neo Presentation
19/49
19192007NOV152007NOV15NEC ConfidentialNEC Confidential
NECs Nodal Radio
IDU Type 2Way Fixed Type 2Way Expandable Type 6Way Box Type
Max. Air Capacity 80Mbps (40E1) 100Mbps (48E1) 100Mbps (48E1)
155Mbps (STM-1)
310Mbps (2xSTM-1)
Interface E1 16ch 16ch / unit 32ch / card
STM-1 (opt)
STM-4 (opt)
LAN
Cooling Natural Forced (FAN) Forced (FAN)
N.A 1ch / unit 1 ~ 4ch / card
N.A N.A 1ch / card
No. of branching 2-Way / Rack 2-Way / IDU(max.8-way / 4IDU)
6-Wa y /Rack(max. 12-Way / 2Rack)
2xFE
N/A
1U
N.A 4FE + 1GbE
Redundant system of DXC N/A Available
Unit Size 1U x 4 + Fan unit 6U ~ 8U
12-Way
8-Way (Max.)
RCPMCP
MODEMMODEM
MODEMMODEM
MODEMMODEM
C ONV C ON V
APAP
APAP
C ONV C ON V
C ONV CO NV
P-INF
AUX/SV
DXCDXC
P-INF
FAN
FAN
RCPMCP
MODEMMODEM
MODEMMODEM
MODEMMODEM
C ONV C ON V
APAPAPAP
C ONV C ON V
CO NV CO NV
P-INF
AUX/SV
DXCDXC
P-INF
FAN
FAN
RCPMCP
MODEMMODEM
MODEMMODEM
MODEMMODEM
C ONV C ON V
APAP
APAP
C ONV C ON V
CO NV CO NV
P-INF
AUX/SV
DXCDXC
P-INF
FAN
FAN6-Way2-Way
2Way Expandable Type2Way Fixed Type 6Way Box Type
2 W NODAL PDH CROSS CONNECT
-
5/26/2018 Copy of Paso Neo Presentation
20/49
20202007NOV152007NOV15NEC ConfidentialNEC Confidential
2 Way NODAL - PDH CROSS CONNECT
Max. 80Mbps(40E1)
Air Capacity
16E1+LAN
2x8E1(D-Sub)
Dir-A
A) Term DXC
D/I for A
DXC
Dir-A
A) Term DXC
D/I for A
DXC
DXC
Dir-A
B) 2way-StarDir-B
D/I for AD/I for B
Dir-A >= Dir-BDXCDXC
Dir-A
B) 2way-StarDir-B
D/I for AD/I for B
Dir-A >= Dir-BDXC
Dir-A
C) 2way-tree
Dir-B
D/I for A
Rep
Dir-A > Dir-BDXC
Dir-A
C) 2way-tree
Dir-B
D/I for A
Rep
Dir-A > Dir-BDXC
Dir-A
D) 2way-Rep
Dir-BRep
Dir-A = Dir-B
D/I = 0
Dir-A
D) 2way-Rep
Dir-BRep
Dir-A = Dir-B
D/I = 0
2 WAY -TREETERMINAL - DXC
2 WAY -STAR 2 WAY -REPEATER
EQUIPMENT SETUPEQUIPMENT SETUP PDH XC INTFCPDH XC INTFC
-
5/26/2018 Copy of Paso Neo Presentation
21/49
21212007NOV152007NOV15NEC ConfidentialNEC Confidential
EQUIPMENT SETUPEQUIPMENT SETUP PDH XC INTFCPDH XC INTFC
Dir -ADir -BRep
DXC
Dir -ADir -BRep
DXC
Dir -A
D/I for A
DXC
Dir -A
D/I for A
DXC
TERMINAL
REPEATER
TERMINAL REPEATER
User Interface PDH E1 with LAN PDH E1 with LAN
Redundancysetting
(1+0) (Term) 2-way PDH
INTFC Main 16E1 2-Way/XC PKG(E/W LAN) 16E1 2-Way/XC PKG(E/W LAN)
Modulation QPSK 16 QAM QPSK QPSK 16QAM 16QAM
10 10 10 10 10 10
80 80 80
TRANSMISSION
CAPACITY
20 20 20 20 20 20
40 40 40 40 40 40
DIR-A DIR-B DIR-A DIR-B
1. Select PDH E1 with LAN as User Interface
2. For Redundancy Setting
Select (1+0) TERM for Terminal Configuration
Select (2-WAY PDH for Repeater Configuration
3. Interface Main: 16E1 2-Way/XC PKG (E/W LAN)
4. Interface Main: 16E1 2-Way/XC PKG (E/W LAN)
5. Select the Modulation scheme. For repeater select
for DIR-A & DIR-B
6. Select the Transmission Capacity. For repeaterselect for DIR-A & DIR-B (Depends on the selected
Modulation scheme
PROVISIONINGPROVISIONING XC SETTING (TERMINAL)XC SETTING (TERMINAL)
-
5/26/2018 Copy of Paso Neo Presentation
22/49
22222007NOV152007NOV15NEC ConfidentialNEC Confidential
PROVISIONINGPROVISIONING XC SETTING (TERMINAL)XC SETTING (TERMINAL)
Dir -A
Tributary LB
DXC
Dir -A
DXC
D/I for A
Select XC Function Enabled to Map the DIR-A and Tributary
Channels as required.
To set all DIR-A channels to
Tributary, one-to-one click
this button
Click and select DIR-A to assign
the radio channels to Tributary
Channels
Click and select Tributary to
assign the Tributary channels to
radio Channels
Click and select for each radio
channel the mapping Tributary or
space (No Assignment)
Click and select the Tributary
Channel number to be assigned
to the radio channel
Click the CH MAP
button to see theconnection graphically
Mapping displayMapping display
-
5/26/2018 Copy of Paso Neo Presentation
23/49
23232007NOV152007NOV15NEC ConfidentialNEC Confidential
Mapping displayMapping display
Assign the channel mapping.
Indicate the mapping
CH MAP : Graphical display of thechannel mapping
LAN ASSIGNMENT NOT SHOWN HERE
Indicate the mapping for each type of channel
Dir-A, DIR-B and Tributary
PROVISIONINGPROVISIONING XC SETTING (REPEATER)XC SETTING (REPEATER)
-
5/26/2018 Copy of Paso Neo Presentation
24/49
24242007NOV152007NOV15NEC ConfidentialNEC Confidential
PROVISIONINGPROVISIONING XC SETTING (REPEATER)XC SETTING (REPEATER)
Show the connection between the radio channels and
the tributary channels
Dir -ADir -BRep
DXC
Dir -ADir -BRep
DXC
Click this button to set all DIR-A channels to Tributary
Channels
Click this button to set all DIR-A channels to DIR-B
Channels (No drop & Insert)
22 Way Expandable Type (4x2Way Expandable Type (4x2 Way)Way)
-
5/26/2018 Copy of Paso Neo Presentation
25/49
25252007NOV152007NOV15NEC ConfidentialNEC Confidential
22--Way Expandable Type (4x2Way Expandable Type (4x2--Way)Way)
Digital Cross Connect function Max. 8-Way Configuration using 4 IDUs
Max. 48E1 (100Mbps) Air Capacity
Air Compatibility with STD PDH menu STM-1 Termination
FAN Unit is necessary
FAN UNIT
Structure ofStructure of 6 Way Box6 Way Box Nodal Radio EquipmentNodal Radio Equipment
-
5/26/2018 Copy of Paso Neo Presentation
26/49
26262007NOV152007NOV15NEC ConfidentialNEC Confidential
yy q pq p
AP (Interface Card)
MODEM
CS(DXC)
OAM&P
RA (Radio Access Card)
AUX
P_INF (Power Supply Card)
F
A
N
AUX : Auxiliary interface Card
OAM&P : Operation, Administration,
Maintenance and Provisioning
Interface Card lineInterface Card line--upup
-
5/26/2018 Copy of Paso Neo Presentation
27/49
27272007NOV152007NOV15NEC ConfidentialNEC Confidential
Interface Card lineInterface Card line upup
Interface Card line-up is as follows.Card Function
32xE1 Interface 32x E1, (2x MDR 68pin)
STM-4 (OPT) Interface 1x STM-4 (SFP)
PDH Fast Ethernet Interface 6x FE (for PDH Radio)
SDH Fast Ethernet Interface 6x FE (for SDH Radio)
SDH Giga-bit Ethernet Interface 2x GbE (for SDH Radio)
STM-1 (OPT/ELE) Interface 4x STM-1 (SFP)
Combination of Interface CardCombination of Interface Card
-
5/26/2018 Copy of Paso Neo Presentation
28/49
28282007NOV152007NOV15NEC ConfidentialNEC Confidential
Combination of Interface CardCombination of Interface Card
Different interface cards are mountable in a same box.
Interface Card
(32E1 INTFC)
(FE INTFC)
(STM-1 ELE)
(STM-1 OPT)
FAIL
PWR
1000BASEPORT1
ACT2ACT1
LINK2LINK1
PORT1P ORT4 P ORT3 P ORT2OUT IN
1000BASEPORT2
OUT IN
FAIL
PWR
PORT1PORT6 PORT5 PORT4 PORT3 PORT2
FAIL
PWR
ONLINEOUT IN
STM-1CH4
1
4 2
3
OUT IN
STM-1CH3
OUT IN
STM-1/4CH2
OUT IN
STM-1/4 CH1
FAIL
PWR
2M IN/ OUT-A 2M IN/OUT-B
FAIL
PWR
ONLINEOUT IN
STM-1CH4
1
4 2
3
OUT IN
STM-1CH3
OUT IN
STM-1/4 CH2
OUT IN
STM-1/4CH1
(GbE INTFC) (STM-4)
FAIL
PWR
ONLINEOUT IN
STM-1CH4
1
4 2
3
OUT IN
STM-1CH3
OUT IN
STM-1/4CH2
OUT IN
STM-1/4 CH1
Five interface card slots
Upgradeable
Scalable
Low initial cost
Network Application (1)Network Application (1)
-
5/26/2018 Copy of Paso Neo Presentation
29/49
29292007NOV152007NOV15NEC ConfidentialNEC Confidential
4x STM-1
NxE1 NxE1
NxE1
NxE1
NxE1
NxE1NxE1NxE1
XPIC
4x STM-1
NEO Nodal
N-way solution for high density site
NEO Standard
NxE1
NxE1
NxE1
NxE1
NxE1
NxE1
NxE1
NxE1
BSC
NEO Standard
Network Application (1)Network Application (1)
- NEO Nodal and NEO Standard can be connected by air.- Different frequencies, capacities, and modulation types are supported in the same box.
Network Application (2)Network Application (2)
-
5/26/2018 Copy of Paso Neo Presentation
30/49
30302007NOV152007NOV15NEC ConfidentialNEC Confidential
STM-4
NxE1
NxE1
NxE1
NxE1
STM-1STM-1
NEO Nodal
N-Way solution for high capacity site
NEO Standard
NxE1
STM-1
NxE1
NxE1
NxE1
STM-1
STM-4
(optical cable)
BSC
Network Application (2)Network Application (2)
NEO Standard
- Planned Support for STM-4 Interface.
- Connection to the core network (BSC, etc.) by Radio, Optical or Ethernet.
Nodal Radio Road Map MenuNodal Radio Road Map Menu
-
5/26/2018 Copy of Paso Neo Presentation
31/49
31312007NOV152007NOV15NEC ConfidentialNEC Confidential
Nodal Radio Road Map Menup
Currently AvailableCurrently Available
2 Way Fixed Type2 Way Fixed Type
2 Way Expandable Type (8 Way)2 Way Expandable Type (8 Way)
ReleaseRelease--11 1Q 20081Q 2008
6-Way Radio
Baseband Interface : STM-1 (OPT/ELE), 32E1
Air Capacity : STM-1, 5-48E1 (Bitrate free)DXC Function (Capacity : 1008x1008E1)
1+0, 1+1 Hot Standby
ReleaseRelease
--22
Under schedulingUnder scheduling
Baseband Interface : FE(SDH), FE(PDH)
CS & RA Module Redundancy
AUX Interface
1+1 Twin Path
-
5/26/2018 Copy of Paso Neo Presentation
32/49
32322007NOV152007NOV15NEC ConfidentialNEC Confidential
PASOLINK NEOPASOLINK NEO
LANLAN (Ethernet)(Ethernet) FunctionFunction SummarySummary
LANLAN (Ethernet)(Ethernet) FunctionFunction SummarySummary
-
5/26/2018 Copy of Paso Neo Presentation
33/49
33332007NOV152007NOV15NEC ConfidentialNEC Confidential
Interface Card 16E1+2LAN INTFC 4LAN +8E1 INTFC E3+2LAN INTFCLAN/WSINTFC
2Way DXC (16E1+2LAN)
System PDH(10~80MB) PDH(80MB) PDH(40~80MB) SDH(156MB) PDH(10~80MB)
10Base-T
100Base-TX
2 (RJ-45)
~80Mbps
N.A
~256Kbps
1548 bytes
1024, 5min
512Kbit
RMON Supported Supported Supported Supported Supported Supported
SDH(156MB)
Address Table / Aging 1024, 5min 1024, 5min 1024, 5min 1024, 5min N.A
Frame Buffer 512Kbit 512Kbit 512Kbit 512Kbit 336Kbit
10Base-T
100Base-TX
2 (RJ-45)
Main N.A
WS N.A N.A ~16Mbps 2Mbps N.A
SC ~256Kbps N.A ~256Kbps ~256Kbps N.A
1548 bytes
GbEINTFC
Interface10Base-T
100Base-TX
10Base-T
100Base-TX
10Base-T
100Base-TX
1000Base-T
1000Base-SX
1000Base-LX
1 (SFP/RJ-45)
150Mbps
9600 bytes
Number of LAN Port 2 (RJ-45) 4 (RJ-45) 2 (RJ-45)
~80Mbps ~100Mbps 150Mbps
Maximum Frame Length 1548 bytes 1548 bytes 1548 bytes
MaximumThroughput
*
*2*2 *2*2 *2
N.A: Not Available*1 1000BASE-LX/SX and 1000BASE-T are exclusive use. (It is not possible to use at the same time.)
*2 When VLAN is enabled, maximum frame length is limited to 1522 bytes.
When VLAN is disabled, ISL transparency transmitting is supported.
Transmission modeTransmission mode (PDH)(PDH)
-
5/26/2018 Copy of Paso Neo Presentation
34/49
34342007NOV152007NOV15NEC ConfidentialNEC Confidential
1. Separated mode
Each Port is completely
independent.
2. Shared mode
All Port are transmitted by
using the same band.
3. Shared mode + Switching Function
PORT 1
PORT 2
PORT 1
PORT 2
A A
B
A B
B
BA
B
A
ST -1 ST -2
Signals can pass between
local ports too.
Transmission modeTransmission mode (SDH)(SDH)
-
5/26/2018 Copy of Paso Neo Presentation
35/49
35352007NOV152007NOV15NEC ConfidentialNEC Confidential
1. 2Port LAN
A : B
a. 75M : 75M
b. 100M : 50M
c. 100M : disable
d. Best Effort
PORT1
PORT2
PORT1
PORT2
A A
B
A
B
ST- 1 ST- 2
150Mbps B
Each Port is completely
independent.
2. GbE LAN
GbE INTFC supports only
one port.
Application exampleApplication example (4port LAN)(4port LAN)
-
5/26/2018 Copy of Paso Neo Presentation
36/49
36362007NOV152007NOV15NEC ConfidentialNEC Confidential
pp ppp p ( p )( p )
Guaranteed bandwidth service
(P1-4 Separated mode)
4 ports are completely separated and guaranteed
maximum throughput for each port.
Data distribution service 1: 4 asymmetrical network, like as connecting datacenter and terminals.(P1-4 Shared mode)
Adaptive Modulation Radio
-
5/26/2018 Copy of Paso Neo Presentation
37/49
37372007NOV152007NOV15NEC ConfidentialNEC Confidential
Two types of AMR (Hit type and Hitless type) are under development.
Even hit type, the interruption time is small (
-
5/26/2018 Copy of Paso Neo Presentation
38/49
38382007NOV152007NOV15NEC ConfidentialNEC Confidential
28MHz
QPSK
20E1
(40Mbps)
Normal conditionCritical condition
28MHz
32QAM
48E1
(100Mbps)
28MHz
16QAM
40E1
(80Mbps)
or
Modulation scheme and Traffic capacity are automatically selected in accordance with the pathcondition.
or LAN
or LAN
Example
IDU Standard
Additional capacity in clear sky conditionby using high density modulation(16QAM/32QAM) in the same channel bandwidth.
Dynamic Modulation Radio
-
5/26/2018 Copy of Paso Neo Presentation
39/49
39392007NOV152007NOV15NEC ConfidentialNEC Confidential
Dynamic Modulation Radio (DMR)
There is interruption when switching
Interruption time : 400msec (NECs specification)
300msec (typical value)
- Dynamic Modulation Radio with 48E1 Interface
Supported Modulation Schemes
-
5/26/2018 Copy of Paso Neo Presentation
40/49
40402007NOV152007NOV15NEC ConfidentialNEC Confidential
Sunny conditionRainy condition
bandwidth
Menu 1: 7MHz
10E1 / 16QAM5E1 / QPSK
Menu 2: 14MHz
20E1 / 16QAM10E1 / QPSK
Menu 3: 28MHz
40E1 / 16QAM20E1 / QPSK
Menu 4: 28MHz
48E1 / 32QAM20E1 / QPSK
SwitchSwitch--over process Exampleover process Example
-
5/26/2018 Copy of Paso Neo Presentation
41/49
41412007NOV152007NOV15NEC ConfidentialNEC Confidential
(48E1/32QAM(48E1/32QAM 20E1/QPSK20E1/QPSK, 28MHz band, 28MHz band))
Switch from
32QAM to QPSK
Switch from
QPSK to 32QAM
32QAM QPSK 32QAM
-73dBm
(48E1/32Q
BER=10-9)
-65dBm
-85dBm
(20E1/QPSK
BER=10-3)
RSL
-76.5dBm
(48E1/32Q
BER=10-3)
Tx power difference(5 dB)
Outage Area(48E1/32QAM)
-70dBm
-60dBm
48E1 20E1 48E1
Operation threshold
Outage Area(20E1/QPSK)
Recovery threshold
-
5/26/2018 Copy of Paso Neo Presentation
42/49
42422007NOV152007NOV15NEC ConfidentialNEC Confidential
Development item
to be made in/after 2008
Traffic ShapingVLAN CARD
-
5/26/2018 Copy of Paso Neo Presentation
43/49
43432007NOV152007NOV15NEC ConfidentialNEC Confidential
QoS Support (802.1p COS)
Data with h igh priority is transmitted
IDU
GbEe.g. STM-1/155Mbps
Queuing
Switch/Router
VL2VL3VL1VL1
VL2
VL3
VLAN with high priority is s tored in
high priority queue buffer.
VL1VL1
.
.
VLAN
tagging
Vo IP
Data-P2
Data-P1
IDU
VL1
VL2
VL3Priority
high
Low VL4
VLAN
tagging
Vo IP
Data-P2
Data-P1
* COS : Class of Service* TOS : Type of Service
Tag-based VLANVLAN CARD
-
5/26/2018 Copy of Paso Neo Presentation
44/49
44442007NOV152007NOV15NEC ConfidentialNEC Confidential
- Tag-based VLAN (802.1Q VLAN)The connection between each clients can be set-up by using VLAN ID.
Connection Example
High Capacity RadioNEO Enhanced
-
5/26/2018 Copy of Paso Neo Presentation
45/49
45452007NOV152007NOV15NEC ConfidentialNEC Confidential
IDUXPIC ODU
STM-2/128QAM
(310MB)
ODUIDUXPIC
28MHz
STM-1
56MHz
STM-2310MB
56MHz28MHz
STM-1
STM-1
V
H
STM-2310MBSTM-2
310MB
STM-1 2xSTM-1/XPIC STM-2 / Carrier 2xSTM-2 / XPIC
STM-2/128QAM
(310MB)
IDU ODUSTM-1
STM-1
STM-1
STM-1
STM-1
STM-1
One Box (IDU)
STM-2/128QAM(310MB)
NEO Enhanced
-
5/26/2018 Copy of Paso Neo Presentation
46/49
46462007NOV152007NOV15NEC ConfidentialNEC Confidential
IDUXPIC
STM-1ODU
STM-2/128QAM(310MB)
ODU
IDUXPICSTM-1 ODU
STM-1/128QAM
XPIC
IDU ODUSTM-1
V
H
IDUXPIC
STM-1
STM-1
STM-1
IDU
replacementonly
IDU
replacement
only
Same ODU
for V and H
Same ODU
for V and H
STM-1/128QAM
STM-2/128QAM(310MB)
2xSTM-1/XPIC 2xSTM-1/Carrier/XPIC
One Box (IDU)
V
H
High Capacity RadioNEO Enhanced
-
5/26/2018 Copy of Paso Neo Presentation
47/49
47472007NOV152007NOV15NEC ConfidentialNEC Confidential
IDUXPIC ODU
STM-2/128QAM
(310MB)
ODUIDUXPIC
56MHz
STM-2310MB
56MHz
STM-2310MBSTM-2
310MB
STM-2 / Carrier
STM-2/128QAM
(310MB)
IDU ODU
2xSTM-2 /XPIC
GbE
GbE
GbE
GbE over STM-4One Box (IDU)
V
H
STM-2/128QAM
(310MB)
High Capacity RadioNEO Enhanced
-
5/26/2018 Copy of Paso Neo Presentation
48/49
48482007NOV152007NOV15NEC ConfidentialNEC Confidential
IDUXPIC ODU
STM-2/128QAM(310MB)
ODUIDUXPIC
56MHz
STM-2310MBSTM-2
310MB
2xSTM-2 / XPIC / STM-4 Interface
STM-4
One Box (IDU)
V
H
STM-2/128QAM(310MB)
Available 2007
Products Road Map
2008
-
5/26/2018 Copy of Paso Neo Presentation
49/49
49492007NOV152007NOV15NEC ConfidentialNEC Confidential
Available 2007 2008 2009
High Capacity
IP Transport
Nodal Radio
Dynamic
Modulation
Radio
16E1+2LAN(80MB)
48E1, 4por t LAN1E3/2E3
STM-1(opt/elec), STM-1(2LAN)
WS/LAN, APS, XPIC
GbE
16E1+2LAN DXC (2Way Repeater)
Standard
Functionality
2xSTM-1/XPIC
80/96E1
/XPIC 2xSTM-2
/XPIC
2Way Repeater
FE, GbE
VLAN/QoS
(4FE, 3FE+GbE)
32E1+2LAN
(100MB)
2/3/4x2Way 4xSTM-1
/XPIC
STM-4 Interface
GbE(620MB)6Way/2x6Way
48E1/DXC
63E1PDH SNCP
Dynamic
Modulation
(hit-type