Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement...

15
Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture

Transcript of Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement...

Page 1: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Conventional Solid Measurement Techniques- Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture

Page 2: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Solution To All the Problems Described in Previous Slide

LOW FREQUENCY 3D ACOUSTICS3D LEVEL SCANNER

Page 3: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Low Frequency and Dust Penetration ChartSignal Attenuation due to Dust/Moisture concentration in air

0

20

40

60

80

100

120

20 40 50 63 100

200

400

630

8001250

2000

3000

4000

6000

8000

10000

15000

20000

frequency(Hz)

Att

enu

atio

n(d

B)

Ultrasonic

Sonic ( 3-4 KHz)

3dB Loss is 50% Loss of Signal Energy

Page 4: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Low Frequency and Dust Penetration• Sound is a pressure wave• Dust particles and Humidity in air

attenuate the wave energy• Attenuation grows sharply over 5 kHz• Low Frequency => Effective Dust

Penetration

Principle Behind Effective Dust penetration : DIFFRACTION around a particle of size less than its wavelength

Page 5: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Beam Angle vs. Frequency

θ - Beam opening angle λ - WavelengthD - Antenna size D

Low Frequency => Wide Beam Angle

Page 6: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Low Frequency => Wide Beam Angle

F = 4.5KHzλ = 7.5cm θ = 60⁰

F = 2.5KHzλ = 13cm θ = 108⁰

F = 10KHzλ = 3.4cm θ = 27⁰

F = 20KHzλ = 1.7cm θ = 13⁰

Page 7: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Low Frequency Acoustics and Self Cleaning AbilityLow Frequency acoustic vibrations prevents sticking of

material to the internal working of the device Ensures long term reliable performance in harsh dusty

conditions

Page 8: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

Low frequency has 4 major advantages

Very low attenuation Easy penetration through dust

Wide angle that covers the whole silo (70-80 degrees)Acoustic vibrations contribute towards the self cleaning

ability

Page 9: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

• 3D Surface mapping requires a 2D array

• 2 Dimensional Array of 3 Antenna

• Estimating per echo:– Distance (R), Azimuth (Ф) and Elevation

(Θ) angles– Convert R, Ф, Θ to Silo X,Y,Z

coordinates

• Final surface reconstruction, based on– Extreme and boundary points – The Material angle of repose– The silo geometry– Acoustics principles

3 Dimensional Surface Reconstruction

Working Principle

Page 10: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

COAL BUNKERS/ FLY ASH / CEMENT/ CLINKER SILOS WARE HOUSES/

OPEN STOCKPILES

FERTILIZER/ CHEMICAL SILOS

Page 11: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

3D Representation of the Device

Page 12: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

3D Representation of the Device

Page 13: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

3D Representation of the Device

Page 14: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.
Page 15: Conventional Solid Measurement Techniques - Narrow Beam Angle -Only Single Point Measurement -Affected By Dust And Moisture.

3D Representation of the Device