Controller Kit Installation Manual MIFH1, MRCH1, MCCH1, MOS1
Transcript of Controller Kit Installation Manual MIFH1, MRCH1, MCCH1, MOS1
© 2010 Mitsubishi Electric & Electronics USA, Inc.Suwanee, GA 30024 All Rights Reserved.
The three diamond logo is a registered trademarkof Mitsubishi Electric Corporation
www.mitsubishipro.com
Controller Kit Installation ManualMIFH1, MRCH1, MCCH1, MOS1
69-2426-01
Installation guide for:
• WirelessReceiverandCable(MIFH1)
• RemoteController(MRCH1)
• PortableCentralController(MCCH1)
• OutdoorAirSensor(MOS1)
DISCONNECT POWER BEFORE BEGINNING INSTALLATION. Can cause electrical shock or equipment damage.
Must be installed by a trained, experienced technician. Read these instructionscarefully.Failuretofollowtheseinstructionscandamagetheproductorcause a hazardous condition.
Installation at a glance
This document covers linking and installation procedures for the Mitsubishi Split-Zoning Ductless and Ducted Systems' RedLINK™ control devices and accessories.
Before you begin, you must attach the cable to the CN105 connector on the indoor unit control board, then follow the steps in this document.
Remote controllers are linked to specific indoor units. Each indoor unit must have a dedicated remote controller and wireless receiver.
Wireless receiver
Wireless outdoor
air sensor
Portable central
controller
M32309
Remote controller
Wireless System Installation Guide
69-2426—01 2
M28474
1 Install batteries in wireless devices
Installbatteriesinalldevices.Makesurebatteriesareinsertedproperly(seepolaritymarksonthedevices).
2 Install cable and receiver
M28472A
Remote Controller
Portable Central Controller (optional): Install 3 fresh AA batteries
Outdoor air sensor (optional): Install 2 fresh AA lithium batteries
Install 2 fresh AA batteries
Install quick reference card
1 Before mounting indoor unit, connect cable to the 5-pin CN105 connector on the control board in the indoor unit.
2 Mount indoor unit. Route cable to preferred location of the wireless receiver.
3 Route cable through hole in base of wireless receiver and attach to 5 pin connector on receiver board.
4 Pushtheexcesscablebackthroughtheindoorunit or behind the wireless receiver. Do not cut or modify the cable. Use zip tie connections on back of receiver if needed.
5 Mountwirelessreceivernexttotheindoorunit(seebelow)orinaremotelocation.
Mount in the orientations shown. Do not block vents.
MCR31400
X
X
OR OR
3 69-2426—01
3 Link all devices to wireless network
1 Remove cover from wireless receiver.
2 VerifyPOWERlightissolidgreen.
3 PressandreleasetheCONNECT button.
4 IfCONNECTlightdoesnotflash,anotherreceiver or RedLINK wireless adapter may be in wirelesssetupmode.Exitwirelesssetupattheother device.
M28925
Wireless Setup
Next
M32308
Connect
Back
Wireless Setup
M32307Done
ConnectedWireless Setup
Link remote controller to wireless networkZone name
Presss or t to change the name or location of this zone, then press NEXT.
Example:67=MeetingRoom
See complete zone list on page 8.
PressCONNECT to establish a link to the wireless network.
If E0 or E1 appears, see error codes on page 10.
After a brief pause, the confirmation screen at left should be displayed to verify that the wireless connection has been established.
PressDONE to display the home screen.
POWER LED
Solid Green:Poweredandcommunicationis established.
Slow Flashing Green (1 flash/second): Receiver is powered. Waitapproximately30secondsforcommunication to be established between the wireless receiver and the indoor unit. Check cable connection if flashing does not stop after 30 seconds.
Fast Flashing Green (5 flashes/second): Error in communication between wireless receiver and the indoor unit. Check cable connection.
CONNECT LED
Flashing Green: In wireless setup mode.
Solid Green: RedLINK communication is established.
Yellow:Pleasewait.
Red: RedLINK device is not communicating.
Flashingstatuslighttimesoutafter15minutesofinactivity.PressCONNECT again if necessary.
Wireless System Installation Guide
69-2426—01 4
Link Portable Central Controller to RedLINK™ network (optional)
Link outdoor sensor to RedLINK™ network (optional)
CONNECT
WIRELESS SETUP
M28481
M28483
NOYES
CONNECT MORE?
M28482
1 MakesuretheCONNECTlightonthewireless receiver is flashing.
2 PressCONNECTatthePortableCentralController. There will be a short delay as the PortableCentralControllerseeksasignalfrom the wireless network.
3 Whenthescreendisplays"Connected,"press DONE.
4 PressNOatthenextscreentosaveandexit.(OrpressYES and repeat steps 1-4 to link anotherreceiver.)
1 MakesuretheCONNECTlightonthewireless receiver is flashing.
2 PressandreleasetheCONNECT button on the back of the sensor.
3 Check remote controller to verify that the outdoor sensor is working. After about 15 seconds, the remote controller should display outdoor temperature and humidity.
Presstolinkanother receiver
Presstosaveandexit
If E1 appears, see error codes on page 10.
The linking procedure may time out if there is no keypress within 15 minutes. To begin again, press and holdtheblankspace(orarrow,ifpresent)inthelowerrightcornerofthescreenuntilthedisplaychanges(about3seconds).
Pressandrelease
5 69-2426—01
Exit wireless setup
4 Customize remote controller (installer setup)
PressandreleasetheCONNECTbuttonatthewirelessreceivertoexitwirelesssetup(lightshouldstopflashingandremainsolid).Replacecoveronwirelessreceiver.
Followthestepsbelowtobegininstallersetup.Ateachfunctionscreen,presss or t to change the setting as desired, then press NEXTtoadvancetothenextfunctionscreen.
Seetablesonpages6-8foradescriptionofoptionsforeachfunction.
Presss or t to change setting(seetablesonpages6-8).
PressNEXTtodisplaynextfunction screen.
Note:Thewirelessreceiverwillautomaticallyexitwirelesssetupafter15minutesof inactivity.
Note:Ifinstallingmorethanonereceiver,youmustexitwirelesssetupbeforeinstalling remote controller and additional receiver.
To begin, press and hold the FAN and s buttonsuntilthedisplaychanges."WAIT"will be displayed for up to 40 seconds.
Function
PressDONEtosave&exit.
Setting
M28927BackDone
Next
M28488A
M289871
Fan
Wireless System Installation Guide
69-2426—01 6
Installer setup tables
Setup function Settings & options (factory default in bold)101 Unit automatically
restarts after power outage
1 OFF2 ON3 Not Supported
103 Ventilation Air 1 Not Supported2 IDUdoesnotintakeoutdoorairthroughLOSSNAY3 IDUdoesintakeoutdoorairthroughLOSSNAY
104 Power Voltage 1 230V2 208V3 Not Supported
105 Auto energy-savings operation
1 ON2 OFF3 Not Supported
107 Change Filter Duration 1 100Hours2 2500Hours3 OFF
108 Auto Fan (speed setting) 1 Quiet2 Standard3 HighCeiling
109 No. of Air Outlets (PLA only)
1 4 directions2 3 directions3 2 directions
110 High Performance Filter Installed
1 NO2 YES3 Not Supported
111 Airflow Direction Settings
1 NoVanes(orVane#3forPLA)2 Vane#1Setting(typicallykeptatthedefaultsetting)3 Vane#2Setting(typicallykeptatthedefaultsetting)
115 Indoor Unit Coil Frost Prevention Temperature
1 36°F(2°C)2 37°F(3°C)3 Not Supported
117 Defrost Control 1 Standard2 HighHumidity3 Not Supported
123 Airflow Oscillate Mode 1 Not Available2 Available3 Not Supported
124 Heating Mode Temperature Offset
1 ON2 OFF3 Not Supported
125 Thermal Off Fan Operation (Heat Mode)
1 ExtraLow2 Stop3 SelectableFanSpeed
127 Thermal Off Fan Operation (Cool Mode)
1 SelectableFanSpeed2 Stop3 Not Supported
128 Display System Error 1 ON2 OFF3 Not Supported
DefaultsettingsforSetupfunctions101-128areautomaticallydeterminedbytheHVACequipment.Itmaytakeupto40secondstoentersetup,and30secondstoexitsetup.
7 69-2426—01
Installer setup tables
Setup function Settings & options (factory default in bold)134 Central Controller
(AG-150 or similar) Present
0 Not Installed 1 Installed
136 Residential/Commercial 1 Commercial0 Residential
138 Permanent Hold Lock (Non-programmable)
0 OFF (Programmable)1 ON(Non-programmable)
139 Fahrenheit/Celsius Display
0 Fahrenheit1 Celsius
140 Commercial Override Duration
3 3 Hours0 OFF1–12 1–12Hours
142 System Type 0 Heat & Cool (Heat Pump)1 CoolOnly
144 System Changeover 1 System Changeover (Auto, Heat, Off, Cool)0 ManualChangeover(Heat,Off,Cool)2 SystemChangeoverOnly(AutoOnly)3 System Changeover Single Setpoint - only with AG-150 or
similar(Auto,Heat,Off,Cool)145 System Changeover
Deadband Value3 3 °F (2 °C)2–8 2–8°F(1.5–4.5°C)
146 Drying Mode 0 OFF1 ON
148 Schedule Format 0 5-21 5-1-1
150 Optimal Start 1 ON0 OFF
152 Scheduled Off 0 Not Shown * See page 9 for feature information1 Shown
154 Power Off Timer ("Sleep Timer")
0 Not Shown1 Resumeoperationatnextscheduledperiod2 PermanentlyOffuntiluserchangesSystemmode
160 Full Lockout 0 No1 Yes
162 Lockout On/Off 0 No1 Yes
164 Lockout System Mode (Heat, Cool, Auto, Drying)
0 No1 Yes
165 Lockout Fan Mode 0 No1 Yes
166 Lockout Setpoint 0 No1 Yes
168 Lockout Set Clock/Day/Schedule
0 No1 Yes
170 Max Heat Setpoint 90 90 °F (32 °C) * Subject to40–89 40to89°F(4.5to31.5°C) HVAC Equipment
172 Min Cool Setpoint 50 50 °F (10 °C) * Subject to51–99 51to99°F(10.5to37°C) HVAC Equipment
173 Sensing Location 1 Sense at Remote Controller0 Sense at Indoor Unit
174 Indoor Temperature Display Offset
0 0 °F (0 °C)-3to3°F(-1.5to1.5°C)
Wireless System Installation Guide
69-2426—01 8
Installer setup tables
Setup function Settings & options (factory default in bold)176 Outdoor Temperature
Display Offset0 0 °F (0 °C)
-5to5°F(-2.5to2.5°C)178 Outdoor Humidity
Display Offset3 0%0 -15%1 -10%2 -5%4 5%5 10%6 15%
192 Zone Name 52 THERMOSTAT 34 MASTER BED1 BASEMENT 35 MEDIAROOM2 BATHROOM 36 MUSICROOM3 BATHROOM1 37 NURSERY4 BATHROOM2 38 OFFICE5 BATHROOM3 39 OFFICE16 BEDROOM 40 OFFICE27 BEDROOM1 41 PANTRY8 BEDROOM2 42 PLAYROOM9 BEDROOM3 43 POOLROOM10 BEDROOM4 44 PORCH11 BOATHOUSE 45 RECROOM12 BONUSROOM 46 SEWINGROOM13 COMPUTERROOM 47 SPA14 DEN 48 STORAGEROOM15 DININGROOM 49 STUDIO16 EXERCISEROOM 50 SUNROOM17 FAMILYROOM 51 THEATER18 FIREPLACE 52 THERMOSTAT19 FOYER 53 UPPERLEVEL20 GAMEROOM 54 UTILITYROOM21 GARAGE 55 WALKINCLOSET22 GREATROOM 56 WINECELLAR23 GUESTROOM 57 WORKSHOP24 GYM Commercial Names25 KID’SROOM 64 CONFERENCERM26 KITCHEN 65 DRESSINGROOM27 KITCHEN1 66 MACHINEROOM28 KITCHEN2 67 MEETINGROOM29 LAUNDRYROOM 68 OPENAREA130 LIBRARY 69 OPENAREA231 LIVINGROOM 70 SERVER 132 LOWERLEVEL 71 SERVER 233 MASTERBATH 72 STOCKROOM
194 Wireless Setup 1 Remote controller is connected to wireless system0 Disconnect Remote controller from wireless system
198 Reset Schedule to Factory Defaults
0 No1 Yes
199 Reset Installer Setup to Factory Defaults
0 No1 Yes
9 69-2426—01
Special functions
Installer test
Followtheprocedurebelowtotestforproperoperation.
M28488A
To begin, press and hold the s and t buttons untilthedisplaychanges(about3seconds).
Presss or t to check system status
PressNEXT to advancetonexttest
PressDONE to terminate system test
M32306
Next
BackDone
System test number System status
System test System status
02 Wireless test 0 Off1 Testradiosignal(afterabriefpause,screendisplays5-10toshow
signalstrength;5orhigherrecommended)
50 Cool/Heat test 0 Off1 Cool2 Heat
70 Configuration Data 1 (remotecontroller)
71 Softwarerevisionnumber(majorrevisions)72 Softwarerevisionnumber(minorrevisions)73 Configurationidentificationcode(major)74 Configurationidentificationcode(minor)75 Productionconfigurationdatecode(week)76 Productionconfigurationdatecode(year)
80 Configuration Data 2 (remotecontroller)
81 Softwarerevisionnumber(majorrevisions)82 Softwarerevisionnumber(minorrevisions)83 Softwarerevisionnumber(buildrevisions)
90 Configuration Data 1 (wirelessreceiver)
91 Softwarerevisionnumber(majorrevisions)92 Softwarerevisionnumber(minorrevisions)93 Softwarerevisionnumber(buildrevisions)
95 Configuration Data 2 (wirelessreceiver)
95 Softwarerevisionnumber(majorrevisions)96 Softwarerevisionnumber(minorrevisions)97 Softwarerevisionnumber(buildrevisions)
Commercial Override (SetupFunction140):Allowsanemployeeduringanunoccupiedperiodto temporarily activate an occupied temperature. Each press of HOLDextendstheoccupiedtemperatureout1hour(orasinstalled).
Optimal Start (SetupFunction150):Allowstheremotecontrollerto“learn”howlongtheequipment will take to reach programmed temperature settings, so the temperature is reached at the scheduled time.
Scheduled Off (SetupFunction152):Allowstheusertoscheduleaperiodwherethesplit-zoningsystemiscompletelyoffandresumesoperationatthenextscheduledperiod.
Power Off Timer (SetupFunction154):Allowsusertoscheduleindoorunitcompletelyoffforoneinstance: FollowScheduleOption:indoorunitwillresumeoperationatthenextscheduledperiod. PermanentlyOffOption:indoorunitwillremainoffindefinitelyuntiltheuserchangesthesystemmode.
Wireless System Installation Guide
69-2426—01 10
Outdoor sensor (optional)
5 Mount remote controller & outdoor sensor1 Separate the wallplate from the remote controller.
2 Mount the wallplate using the included screws and anchors 5 feet from the floor on an interior wall. If the remote controller is configured to sense indoor temperature, mount in the same room as the indoor unit.
Drill3/16"holesfordrywall. Drill7/32"holesforplaster.
3 Snap the remote controller to the wallplate on the wall.
M28491
M28492
Mountthesensoronaverticalexteriorwall,atleast6inchesbelowanyoverhang. Choose a location protected from direct sunlight.
Placesensorsecurelyin bracket, facing
away from wall.
RedLINK™ error codes
E0 27 Verify device temperature is within operating range. If within range for at least 30 minutes and problem persists, replace Remote Controller.
E0 91 Communication was established between wireless receiver and the indoor unit, but communication has been lost for 10 minutes. Check cable connection. Try replacing the cable.
E1 29 Attempting to connect incompatible wireless devices.
E1 34 Low signal strength. Move wireless device to a different location and try again.
E1 38 Make sure Connect light on wireless receiver is flashing and you are 2+ feet away from wireless receiver.
E1 54 Indoor unit does not support wireless receiver.
Forfulllistoferrorcodes,pleaserefertoyourequipment'stechnicalservicemanual.
11 69-2426—01
Replacing system components
Note:OnlyuseMitsubishiElectriccomponentsorotherdesignatedcomponentsforinstallation.Failuretocomplymaydamagetheproductorcauseahazardouscondition.
Remote Controller
To replace a remote controller, install batteries and follow the procedures on page 3tolinkittothewirelessnetwork.Ifnecessary,modifysettingsasneeded(seetablesonpages6–8).
Portable Central Controller & outdoor sensor
ToreplaceaPortableCentralControlleroroutdoorairsensor,installbatteriesandfollow the procedures on page 4 to link it to the wireless network.
Wireless receiver
After installing a new wireless receiver, you must re-set the remote controller and PortableCentralControllertocommunicatewiththenewequipment,asdescribedbelow.
Removing all wireless devices:1 Pressandhold the CONNECT button on the wireless receiver for 10 seconds.
2 To reconnect, see procedure on page 3.
Attheremotecontroller:
1 Pressandhold the FAN and s buttons for 3 seconds until display changes. "WAIT"willbedisplayedforupto17seconds.
2 PressNEXTuntilFunction194isdisplayed(wirelesssetup).
3 PressttochangeFunction194settingto0(disconnectfromoldwirelessreceiver).
4 Followtheproceduresonpage3tolinktonewwirelessreceiver.
AtthePortableCentralController:1 Pressandholdtheblankspace(orarrowif
present)inthelowerrightcornerofthescreenuntilthedisplaychanges(about3seconds).
2 PressREMOVE, then YES to disconnect from old wireless receiver.
3 Followtheprocedureonpage4tolinktonewwireless receiver.
© 2010 Mitsubishi Electric & Electronics USA, Inc.Suwanee, GA 30024 All Rights Reserved.The three diamond logo is a registered trademarkof Mitsubishi Electric Corporation69-2426—01M.S.11-10PrintedinU.S.A.
Regulatory informationFCC Compliance Statement (Part 15.19) (USA only) ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
1 This device may not cause harmful interference, and2 This device must accept any interference received, including interference that may cause undesired operation.
FCC Warning (Part 15.21) (USA only) Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperate the equipment.
FCC Interference Statement (Part 15.105 (b)) (USA only) ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorientorrelocatethereceivingantenna.• Increasetheseparationbetweentheequipmentandreceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Wireless receiver, remote controller and outdoor sensor TocomplywithFCCandIndustryCanadaRFexposurelimitsforgeneralpopulation/uncontrolledexposure,theantenna(s)usedfor these transmitters must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-locatedoroperatinginconjunctionwithanyotherantennaortransmitter.
Portable Central Controller ThisportabletransmitterwithitsantennacomplieswithFCCandIndustryCanadaRFexposurelimitsforgeneralpopulation/uncontrolledexposure.Thisdevicemustnotbeco-locatedoroperatinginconjunctionwithanyotherantennaortransmitter.
Section 7.1.5 of RSS-GEN Operationissubjecttothefollowingtwoconditions:
1 this device may not cause interference, and2 this device must accept any interference, including interference that may cause undesired operation of the device.
Specifications & replacement partsOperating Ambient Temperature
Remote Controller:32to120°F(0to48.9°C)Portable Central Controller:32to120°F(0to
48.9°C)Wireless receiver:-40to165°F(-40to73.9°C)Outdoor air sensor:-40to140°F(-40to60°C)
Operating Relative HumidityRemote Controller:5%to90%(non-
condensing)Portable Central Controller:5%to90%(non-
condensing)Wireless receiver:5%to95%(non-condensing)Outdoor air sensor:0%to100%(condensing)
Physical Dimensions(height,width,depth)Remote Controller:3-9/16x5-13/16x1-1/2
inches(91x147x38mm)Wireless receiver:6-7/16x3-1/4x1-5/16
inches(164x82.5x34mm)Outdoor air sensor:5x3-1/2x1-11/16inches
(127x89x43mm)Portable Central Controller:6-1/4x3-1/8x
1-5/8inches(158.2x79.9x42mm)
Item Part Number
PortableCentralController MCCH1
Outdoorairsensor MOS1
RemoteController MRCH1
ReceiverandCable MIFH1
Cable MRC1
Accessories & Replacement Parts