Product OverviewKingspan Controlled Environment panels are designed for use

within temperature controlled and hygiene safe environments, such

as food processing, freezers, cold/chill store and clean rooms for

the bio-technology and pharmaceutical industries.

These firesafe, hygienic and fibre free insulated panel systems are

suitable for internal and external walls and ceilings, including

internal ‘box within a box’ applications.

ManufacturePanels are manufactured in a Kingspan owned facility in Sydney,

Australia. Lead times are typically 4-5 weeks for stocked coatings

and colours. Non stocked coatings/colours require extra lead time.

Panel Performance

Panel Properties and Thermal Performance

Core Thickness (mm) 50 75 100 125 150 200

R Value (m2/kW) 2.65 3.9 5.15 6.40 7.65 10.00

Weight kg/m2 0.5/0.5 steel 10.00 11.00 12.10 13.01 14.20 16.30

Internal Surface Finish (NZBC Cl 4.17)

Standard Details Firewall Details

Group 1S Group 1S

External Radiation (NZBC Cl 5.8)

Total Heat Peak Heat >1m from <1m from

THRR PHRR boundary boundary

24 kW/m2 5 mJ/m2 � �

NZBCThe KS1100 CS panel is compliant with the following clauses of

the NZBC, when Kingspan standard details are utilised:

B1 Structure B2 Durability C Fire

E2 External Water H1 Energy Efficiency

Sprinkler Code NZS 4541:2007The Sprinkler Standard NZS 4541:2007 contains levels of sprinkler

protection required for buildings constructed with “Approved” and

“Not Approved” panels - refer to section 212 and Appendix J.

Kingspan PIR panels are classed as “approved” as they have FM

Global approval.

Available LengthsStandard lengths are from 2m to 11.8m.

1100mm cover width

RibKS1100 CS

FlatKS1100 CS

*panel shown is KS1100 CS Rib/Rib

KS1100 CSTechnical Data

3

FirewallVarious tested Firewall solutions are available. All of these solutions

require a specific construction to match the tested performance.

Contact Kingspan with your specific requirements and we will

provide an appropriate solution.

InsuranceKingspan panels have achieved FM Global � FM4880 Class 1 - unlimited height

(the highest classification available)� FM4881 - External Wall System - no height restriction

Acoustic PerformanceFor sound transmission reduction, Kingspan panels typically have a

single figure weighted sound reduction index (SRI) of Rw=24dB.

For New Zealand specific acoustic solutions contact Kingspan

Technical Services.

MaterialsExterior Weather Sheet

Substrate to be 0.50mm thick Z275 Zincform G300S coated steel

to AS1397.� Standard Colour – Antibacterial White - 25 microns thick

� Other colours available on extended lead time and price

Insulation Core

Polyisocyanurate (PIR), with zero Ozone Depletion Potential (Zero

ODP). Available in FM Global insurer approved Firesafe certified

product range.

PIR foam is a thermosetting material. It does not melt, flow or drip

when exposed to fire. It forms a strong char that helps protect the

foam core and prevent flame spread within the panels.

Internal Liner Sheet

Substrate to be 0.50mm thick Z275 Zincform G300S coated steel

to AS1397.� Standard Colour – Antibacterial White - 25 microns thick

� Other colours available on extended lead time and price

Fasteners

All fixings (screws, rivets or bolts) to be either Carbon or stainless

steel.

Flashings

All flashings to be 0.5mm coil coated steel. No aluminium to be

used.

Product Selection AssistanceSales representatives are available nationwide to answer queries on

product options, assist with detailing, spans, colour swatches and

other queries. They can also provide early stage budget estimates

and co-ordinate the provision of project specifications.

Technical AssistanceOur technical team is available to provide specific advice on panel

spans, product specifications, standard and bespoke detailing,

panel optimisation, fire wall options, project specific acoustic

solutions, panel guarantees, thermal condensation risk calculation

along with general building science cladding advice.

Kingspan Technical Services can provide ‘side by side’ assistance

with regard to project detailing, attending design meetings,

providing training and undertaking site visits when required.

GuaranteesKingspan will provide product guarantees on an individual project

basis.

Guarantees are typically up to 10 years in a non marine /

geothermal environment. All guarantees are subject to maintenance

regime. Specialist coatings are available for marine and other more

corrosive areas.

EnvironmentalKingspan has undertaken a Life Cycle assessment of the

KS1100 CS panels, and have published an Environmental Product

Declaration (EPD) on their performance. The result shows that the

Australian made panels are consistent with the Green Guide A+

rating achieved by the UK sourced materials.

BiologicalKingspan panels are normally immune to attack from mould, fungi,

mildew, and vermin. No urea or formaldehyde is used in the

construction, and the panels are not considered deleterious to

health.

Quality and DurabilityKS1100 CS panels are manufactured to ISO 9001 standards from

the highest quality materials, using state of the art production

equipment to rigorous quality control standards, ensuring long term

reliability and service life.

Delivery & PackingStandard Packing

Protective film is applied to the external face.

Kingspan panels are stacked horizontally.

The number of panels in each pack depends on panel thickness.

Delivery

All deliveries (unless indicated otherwise) are by road transport to

project site by flat bed truck for off loading by crane or fork hoist.

Off loading is the responsibility of the installer.

Handling guidelines are available from Kingspan Technical Services.

Frequency (Hz) 125 250 500 1000 2000 4000 Rw

SRI (dB) 17 21 26 26 26 42 24

4

KS1100 CSSpan Tables

Internal Wall &Ceilings

KS1100 CS Span Tables - Internal Wall and Ceiling

Panel TemperatureThickness R Value Weight Delta Range (1) Internal Walls (2) Trafficable Ceilings (3)mm (m2k/w) (kg/m2) (ºC) Ambient (m) Freezer (m) Ambient (m) Freezer (m)50 2.65 10.00 25 6.29 N/A 3.01 N/A

75 3.90 11.00 40 8.27 N/A 4.69 N/A

100 5.15 12.10 50 10.04 7.68 6.19 8.64

125 6.40 13.01 60 11.67 9.11 7.56 10.40

150 7.65 14.20 75 11.80* 10.46 8.81 11.72

200 10.00 16.30 100 11.80* 11.80* 10.65 11.80*

(1) Based on heat flow of 10W/m2/hr - as per following table.(2) Internal wall spans based on 0.30 kpa load. Deflection limit L/100(3) Ceilings based on either 1.4kN or 0.25 kpa loads. Deflection limit L/200 short term or L/100 long term.(4) Ambient = 0ºC to 0ºC and Freezer = -25ºC to 20ºC.

Notes:� Values have been calculated in accordance with AS/NZS1170.0 and also take into account the method described in EN 14509:2006 titled ‘Self-supporting

double skin metal face insulating panels (Light coloured). Factory made products - Specifications’, taking imposed loads and temperature into account.� The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services.� The allowable steelwork tolerance between bearing panels of adjacent supports is +/- 5mm or L/600.� * Max panel length is 11.80m� Load span tables for the panel specifications not shown are available from Kingspan Technical Services.

Heat Transmission

D = (λ x Δt)/Q

D = Panel thickness (m)

λ = 0.020 W/mK, thermal conductivity of the panel

Δt = Difference between internal and external temperatures

Q = 10 W/m2 design heat flow for refrigeration

Heat Flow (w/m2)Panel Thickness in mm

50 75 100 125 150 20025 10.00 6.67 5.00 4.00 3.33 2.5030 12.00 8.00 6.00 4.80 4.00 3.0035 14.00 9.33 7.00 5.60 4.67 3.5040 16.00 10.67 8.00 6.40 5.33 4.0045 12.00 9.00 7.20 6.00 4.5050 13.33 10.00 8.00 6.67 5.0055 14.67 11.00 8.80 7.33 5.5060 12.00 9.60 8.00 6.0065 13.00 10.40 8.67 6.5070 14.00 11.20 9.33 7.0075 12.00 10.00 7.5080 12.80 10.67 8.0085 13.60 11.33 8.5090 12.00 9.0095 12.67 9.50

100 13.33 10.00

Tem

per

atur

e D

iffer

ence

(ºC

)

Panel External Temperature ºC Internal Temperature ºCThickness (mm) 30 20 10 0 -10 -20 -30 -40 -50 -60 -705075

100125150200

Operating Ranges

5

KS1100 CSSpan Tables

External WallChiller (0ºC Internal)

Single Span Condition

Panel Load Span L in metresThickness Type 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5mm Uniformly distributed loads kN/m2

Ultimate Limit State (ULS)

50 Pressure 2.07Suction 2.05

75 Pressure 3.16 2.32 1.78 1.40Suction 3.05 2.24 1.71 1.35

100 Pressure 4.25 3.12 2.39 1.89 1.53 1.27 1.06Suction 4.02 2.95 2.26 1.79 1.45 1.20 1.01

125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35 1.15 0.99 0.87Suction 5.03 3.69 2.83 2.23 1.81 1.50 1.26 1.07 0.92 0.80

150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06 0.93 0.82Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.49 1.27 1.10 0.96 0.84 0.74

200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98

Serviceability Limit State (SLS)

50 Pressure 1.58Suction 0.88

75 Pressure 3.14 2.24 1.63 1.22Suction 2.50 1.70 1.14 0.68

100 Pressure 4.25 3.12 2.39 1.86 1.53 1.27 1.06Suction 4.02 2.95 2.26 1.58 1.17 0.83 0.55

125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35 1.15 0.99Suction 5.03 3.69 2.83 2.23 1.81 1.46 1.13 0.89 0.65

150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06 0.93 0.82Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.49 1.27 1.10 0.88 0.70 0.53

200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98

Double Span Condition

Panel Load Span L in metresThickness Type 3.0 3.5 4.0 4.5 5.0 5.5 5.9mm Uniformly distributed loads kN/m2

Ultimate Limit State (ULS)

50 Pressure 2.07 1.52Suction 2.05 1.51

75 Pressure 3.16 2.32 1.78 1.40Suction 3.05 2.24 1.71 1.35

100 Pressure 4.25 3.12 2.39 1.89 1.53Suction 4.02 2.95 2.26 1.79 1.45

125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61Suction 5.03 3.69 2.83 2.23 1.81 1.50

150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97Suction 5.97 4.39 3.36 2.66 2.15 1.78

200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97

Serviceability Limit State (SLS)

50 Pressure 1.58 1.12Suction 0.88 0.75

75 Pressure 2.64 1.77 1.27 0.96Suction 2.57 1.43 0.87 0.56

100 Pressure 3.74 2.46 1.73 1.29 1.00Suction 3.55 2.35 1.40 0.89 0.59

125 Pressure 3.87 3.17 2.21 1.63 1.25 0.99Suction 3.50 2.99 2.04 1.28 0.84 0.57

150 Pressure 3.88 3.29 2.69 1.96 1.49 1.17Suction 3.46 2.94 2.55 1.55 0.99 0.65

200 Pressure 4.22 3.56 3.09 2.60 1.95 1.52 1.21Suction 3.71 3.14 2.74 2.13 1.28 0.78 0.48

Maxim

um leng

th for

containerisatio

n is 11.8m(2 x 5.9m

= 11.8m

)

Maxim

um leng

th for

containerisatio

n is 11.8m(2 x 5.9m

= 11.8m

)

For span parameters, refer to notes at the bottom of page 6.

L

L L

KS1100 CSSpan Tables

External WallFreezer (-25ºC Internal)

6

Notes:� Values have been calculated in accordance with AS/NZS 1170.0 and also take into account the methods described in EN 14509:2006 titled ‘Self-supporting

double skin metal face insulating panels (Light coloured) – Factory made products – Specifications’, taking imposed loads and temperature into account.� The serviceability limit state is defined by local buckling, bending or crushing failure at an intermediate support or the exceedance of a specified deflection limit.� A deflection limit of L/100 was used.� The table is for an internal temperature of 0ºC for chiller and -25ºC for freezer.� The actual wind suction load resisted by the panel is dependant on the number of fasteners used and the support width as well as the fastener material. This

table is based on a support width of 60mm.� The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services.� The allowable steelwork tolerance between bearing panels of adjacent supports is +/- 5mm or L/600.� Load span tables for the panel specifications not shown are available from Kingspan Technical Services.

Single Span Condition

Panel Load Span L in metresThickness Type 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5mm Uniformly distributed loads kN/m2

Ultimate Limit State (ULS)

100 Pressure 4.25 3.12 2.39 1.89 1.53Suction 4.02 2.95 2.26 1.79 1.45

125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35 1.15 0.99 0.87Suction 5.03 3.69 2.83 2.23 1.81 1.50 1.26 1.07 0.92 0.80

150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06 0.93 0.82Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.49 1.27 1.10 0.96 0.84 0.74

200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98

Serviceability Limit State (SLS)

100 Pressure 4.25 3.12 2.39 1.86 1.53Suction 3.83 2.66 1.86 1.13 0.65

125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35Suction 5.03 3.69 2.83 2.20 1.63 1.09 0.71

150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.45 1.03 0.72 0.49

200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98

L

7

Case Studies

Lion Brewery, Auckland� New build � Wall: KS1100 CS � Ceiling: KS1100 CS

Fonterra Coldstore, Whareroa� New build � Wall: KS1100 CS � Ceiling: KS1100 CS

French Bakery, Christchurch � New build � Wall: KS1100 CS � Ceiling: KS1100 CS

Coles Distribution, Victoria, Australia� New build � Wall: KS1100 CS � Ceiling: KS1100 CS

Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Ltd and its subsidiary companies do not accept responsibility for errors or for informationthat is found to be misleading. Suggestions for, or descriptions of, the end use or application of products or methods of working are for information only and Kingspan Ltd and itssubsidiaries accept no liability in respect thereof.

I n s u l a t e d Pa n e l s 03/2017

New Zealand: Kingspan Ltd 97 Montreal Street, Christchurch, New Zealand Freephone (0800) 12 12 80 t: +64 (03) 260 5530 f: +64 (03) 260 5539 e: [email protected] www.kingspanpanels.co.nz