Controlled KS1100 CS Environments Data Sheet · the bio-technology and pharmaceutical industries....
Transcript of Controlled KS1100 CS Environments Data Sheet · the bio-technology and pharmaceutical industries....
I n s u l a t e d Pa n e l s
Controlled Environments
KS1100 CSData Sheet
Controlled Environment Panels
KS1100 CSTechnical Data
2
Product OverviewKingspan Controlled Environment panels are designed for use
within temperature controlled and hygiene safe environments, such
as food processing, freezers, cold/chill store and clean rooms for
the bio-technology and pharmaceutical industries.
These firesafe, hygienic and fibre free insulated panel systems are
suitable for internal and external walls and ceilings, including
internal ‘box within a box’ applications.
ManufacturePanels are manufactured in a Kingspan owned facility in Sydney,
Australia. Lead times are typically 4-5 weeks for stocked coatings
and colours. Non stocked coatings/colours require extra lead time.
Panel Performance
Panel Properties and Thermal Performance
Core Thickness (mm) 50 75 100 125 150 200
R Value (m2/kW) 2.65 3.9 5.15 6.40 7.65 10.00
Weight kg/m2 0.5/0.5 steel 10.00 11.00 12.10 13.01 14.20 16.30
Internal Surface Finish (NZBC Cl 4.17)
Standard Details Firewall Details
Group 1S Group 1S
External Radiation (NZBC Cl 5.8)
Total Heat Peak Heat >1m from <1m from
THRR PHRR boundary boundary
24 kW/m2 5 mJ/m2 � �
NZBCThe KS1100 CS panel is compliant with the following clauses of
the NZBC, when Kingspan standard details are utilised:
B1 Structure B2 Durability C Fire
E2 External Water H1 Energy Efficiency
Sprinkler Code NZS 4541:2007The Sprinkler Standard NZS 4541:2007 contains levels of sprinkler
protection required for buildings constructed with “Approved” and
“Not Approved” panels - refer to section 212 and Appendix J.
Kingspan PIR panels are classed as “approved” as they have FM
Global approval.
Available LengthsStandard lengths are from 2m to 11.8m.
1100mm cover width
RibKS1100 CS
FlatKS1100 CS
*panel shown is KS1100 CS Rib/Rib
KS1100 CSTechnical Data
3
FirewallVarious tested Firewall solutions are available. All of these solutions
require a specific construction to match the tested performance.
Contact Kingspan with your specific requirements and we will
provide an appropriate solution.
InsuranceKingspan panels have achieved FM Global � FM4880 Class 1 - unlimited height
(the highest classification available)� FM4881 - External Wall System - no height restriction
Acoustic PerformanceFor sound transmission reduction, Kingspan panels typically have a
single figure weighted sound reduction index (SRI) of Rw=24dB.
For New Zealand specific acoustic solutions contact Kingspan
Technical Services.
MaterialsExterior Weather Sheet
Substrate to be 0.50mm thick Z275 Zincform G300S coated steel
to AS1397.� Standard Colour – Antibacterial White - 25 microns thick
� Other colours available on extended lead time and price
Insulation Core
Polyisocyanurate (PIR), with zero Ozone Depletion Potential (Zero
ODP). Available in FM Global insurer approved Firesafe certified
product range.
PIR foam is a thermosetting material. It does not melt, flow or drip
when exposed to fire. It forms a strong char that helps protect the
foam core and prevent flame spread within the panels.
Internal Liner Sheet
Substrate to be 0.50mm thick Z275 Zincform G300S coated steel
to AS1397.� Standard Colour – Antibacterial White - 25 microns thick
� Other colours available on extended lead time and price
Fasteners
All fixings (screws, rivets or bolts) to be either Carbon or stainless
steel.
Flashings
All flashings to be 0.5mm coil coated steel. No aluminium to be
used.
Product Selection AssistanceSales representatives are available nationwide to answer queries on
product options, assist with detailing, spans, colour swatches and
other queries. They can also provide early stage budget estimates
and co-ordinate the provision of project specifications.
Technical AssistanceOur technical team is available to provide specific advice on panel
spans, product specifications, standard and bespoke detailing,
panel optimisation, fire wall options, project specific acoustic
solutions, panel guarantees, thermal condensation risk calculation
along with general building science cladding advice.
Kingspan Technical Services can provide ‘side by side’ assistance
with regard to project detailing, attending design meetings,
providing training and undertaking site visits when required.
GuaranteesKingspan will provide product guarantees on an individual project
basis.
Guarantees are typically up to 10 years in a non marine /
geothermal environment. All guarantees are subject to maintenance
regime. Specialist coatings are available for marine and other more
corrosive areas.
EnvironmentalKingspan has undertaken a Life Cycle assessment of the
KS1100 CS panels, and have published an Environmental Product
Declaration (EPD) on their performance. The result shows that the
Australian made panels are consistent with the Green Guide A+
rating achieved by the UK sourced materials.
BiologicalKingspan panels are normally immune to attack from mould, fungi,
mildew, and vermin. No urea or formaldehyde is used in the
construction, and the panels are not considered deleterious to
health.
Quality and DurabilityKS1100 CS panels are manufactured to ISO 9001 standards from
the highest quality materials, using state of the art production
equipment to rigorous quality control standards, ensuring long term
reliability and service life.
Delivery & PackingStandard Packing
Protective film is applied to the external face.
Kingspan panels are stacked horizontally.
The number of panels in each pack depends on panel thickness.
Delivery
All deliveries (unless indicated otherwise) are by road transport to
project site by flat bed truck for off loading by crane or fork hoist.
Off loading is the responsibility of the installer.
Handling guidelines are available from Kingspan Technical Services.
Frequency (Hz) 125 250 500 1000 2000 4000 Rw
SRI (dB) 17 21 26 26 26 42 24
4
KS1100 CSSpan Tables
Internal Wall &Ceilings
KS1100 CS Span Tables - Internal Wall and Ceiling
Panel TemperatureThickness R Value Weight Delta Range (1) Internal Walls (2) Trafficable Ceilings (3)mm (m2k/w) (kg/m2) (ºC) Ambient (m) Freezer (m) Ambient (m) Freezer (m)50 2.65 10.00 25 6.29 N/A 3.01 N/A
75 3.90 11.00 40 8.27 N/A 4.69 N/A
100 5.15 12.10 50 10.04 7.68 6.19 8.64
125 6.40 13.01 60 11.67 9.11 7.56 10.40
150 7.65 14.20 75 11.80* 10.46 8.81 11.72
200 10.00 16.30 100 11.80* 11.80* 10.65 11.80*
(1) Based on heat flow of 10W/m2/hr - as per following table.(2) Internal wall spans based on 0.30 kpa load. Deflection limit L/100(3) Ceilings based on either 1.4kN or 0.25 kpa loads. Deflection limit L/200 short term or L/100 long term.(4) Ambient = 0ºC to 0ºC and Freezer = -25ºC to 20ºC.
Notes:� Values have been calculated in accordance with AS/NZS1170.0 and also take into account the method described in EN 14509:2006 titled ‘Self-supporting
double skin metal face insulating panels (Light coloured). Factory made products - Specifications’, taking imposed loads and temperature into account.� The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services.� The allowable steelwork tolerance between bearing panels of adjacent supports is +/- 5mm or L/600.� * Max panel length is 11.80m� Load span tables for the panel specifications not shown are available from Kingspan Technical Services.
Heat Transmission
D = (λ x Δt)/Q
D = Panel thickness (m)
λ = 0.020 W/mK, thermal conductivity of the panel
Δt = Difference between internal and external temperatures
Q = 10 W/m2 design heat flow for refrigeration
Heat Flow (w/m2)Panel Thickness in mm
50 75 100 125 150 20025 10.00 6.67 5.00 4.00 3.33 2.5030 12.00 8.00 6.00 4.80 4.00 3.0035 14.00 9.33 7.00 5.60 4.67 3.5040 16.00 10.67 8.00 6.40 5.33 4.0045 12.00 9.00 7.20 6.00 4.5050 13.33 10.00 8.00 6.67 5.0055 14.67 11.00 8.80 7.33 5.5060 12.00 9.60 8.00 6.0065 13.00 10.40 8.67 6.5070 14.00 11.20 9.33 7.0075 12.00 10.00 7.5080 12.80 10.67 8.0085 13.60 11.33 8.5090 12.00 9.0095 12.67 9.50
100 13.33 10.00
Tem
per
atur
e D
iffer
ence
(ºC
)
Panel External Temperature ºC Internal Temperature ºCThickness (mm) 30 20 10 0 -10 -20 -30 -40 -50 -60 -705075
100125150200
Operating Ranges
5
KS1100 CSSpan Tables
External WallChiller (0ºC Internal)
Single Span Condition
Panel Load Span L in metresThickness Type 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5mm Uniformly distributed loads kN/m2
Ultimate Limit State (ULS)
50 Pressure 2.07Suction 2.05
75 Pressure 3.16 2.32 1.78 1.40Suction 3.05 2.24 1.71 1.35
100 Pressure 4.25 3.12 2.39 1.89 1.53 1.27 1.06Suction 4.02 2.95 2.26 1.79 1.45 1.20 1.01
125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35 1.15 0.99 0.87Suction 5.03 3.69 2.83 2.23 1.81 1.50 1.26 1.07 0.92 0.80
150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06 0.93 0.82Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.49 1.27 1.10 0.96 0.84 0.74
200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98
Serviceability Limit State (SLS)
50 Pressure 1.58Suction 0.88
75 Pressure 3.14 2.24 1.63 1.22Suction 2.50 1.70 1.14 0.68
100 Pressure 4.25 3.12 2.39 1.86 1.53 1.27 1.06Suction 4.02 2.95 2.26 1.58 1.17 0.83 0.55
125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35 1.15 0.99Suction 5.03 3.69 2.83 2.23 1.81 1.46 1.13 0.89 0.65
150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06 0.93 0.82Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.49 1.27 1.10 0.88 0.70 0.53
200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98
Double Span Condition
Panel Load Span L in metresThickness Type 3.0 3.5 4.0 4.5 5.0 5.5 5.9mm Uniformly distributed loads kN/m2
Ultimate Limit State (ULS)
50 Pressure 2.07 1.52Suction 2.05 1.51
75 Pressure 3.16 2.32 1.78 1.40Suction 3.05 2.24 1.71 1.35
100 Pressure 4.25 3.12 2.39 1.89 1.53Suction 4.02 2.95 2.26 1.79 1.45
125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61Suction 5.03 3.69 2.83 2.23 1.81 1.50
150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97Suction 5.97 4.39 3.36 2.66 2.15 1.78
200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97
Serviceability Limit State (SLS)
50 Pressure 1.58 1.12Suction 0.88 0.75
75 Pressure 2.64 1.77 1.27 0.96Suction 2.57 1.43 0.87 0.56
100 Pressure 3.74 2.46 1.73 1.29 1.00Suction 3.55 2.35 1.40 0.89 0.59
125 Pressure 3.87 3.17 2.21 1.63 1.25 0.99Suction 3.50 2.99 2.04 1.28 0.84 0.57
150 Pressure 3.88 3.29 2.69 1.96 1.49 1.17Suction 3.46 2.94 2.55 1.55 0.99 0.65
200 Pressure 4.22 3.56 3.09 2.60 1.95 1.52 1.21Suction 3.71 3.14 2.74 2.13 1.28 0.78 0.48
Maxim
um leng
th for
containerisatio
n is 11.8m(2 x 5.9m
= 11.8m
)
Maxim
um leng
th for
containerisatio
n is 11.8m(2 x 5.9m
= 11.8m
)
For span parameters, refer to notes at the bottom of page 6.
L
L L
KS1100 CSSpan Tables
External WallFreezer (-25ºC Internal)
6
Notes:� Values have been calculated in accordance with AS/NZS 1170.0 and also take into account the methods described in EN 14509:2006 titled ‘Self-supporting
double skin metal face insulating panels (Light coloured) – Factory made products – Specifications’, taking imposed loads and temperature into account.� The serviceability limit state is defined by local buckling, bending or crushing failure at an intermediate support or the exceedance of a specified deflection limit.� A deflection limit of L/100 was used.� The table is for an internal temperature of 0ºC for chiller and -25ºC for freezer.� The actual wind suction load resisted by the panel is dependant on the number of fasteners used and the support width as well as the fastener material. This
table is based on a support width of 60mm.� The fastener calculation should be carried out in accordance with the appropriate standards. For further advice please contact Kingspan Technical Services.� The allowable steelwork tolerance between bearing panels of adjacent supports is +/- 5mm or L/600.� Load span tables for the panel specifications not shown are available from Kingspan Technical Services.
Single Span Condition
Panel Load Span L in metresThickness Type 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5mm Uniformly distributed loads kN/m2
Ultimate Limit State (ULS)
100 Pressure 4.25 3.12 2.39 1.89 1.53Suction 4.02 2.95 2.26 1.79 1.45
125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35 1.15 0.99 0.87Suction 5.03 3.69 2.83 2.23 1.81 1.50 1.26 1.07 0.92 0.80
150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06 0.93 0.82Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.49 1.27 1.10 0.96 0.84 0.74
200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98
Serviceability Limit State (SLS)
100 Pressure 4.25 3.12 2.39 1.86 1.53Suction 3.83 2.66 1.86 1.13 0.65
125 Pressure 5.41 3.98 3.05 2.41 1.95 1.61 1.35Suction 5.03 3.69 2.83 2.20 1.63 1.09 0.71
150 Pressure 6.23 4.86 3.72 2.94 2.38 1.97 1.65 1.41 1.21 1.06Suction 5.97 4.39 3.36 2.66 2.15 1.78 1.45 1.03 0.72 0.49
200 Pressure 6.80 5.83 5.09 4.02 3.26 2.69 2.26 1.93 1.66 1.45 1.27 1.13Suction 6.80 5.80 4.44 3.51 2.84 2.35 1.97 1.68 1.45 1.26 1.11 0.98
L
7
Case Studies
Lion Brewery, Auckland� New build � Wall: KS1100 CS � Ceiling: KS1100 CS
Fonterra Coldstore, Whareroa� New build � Wall: KS1100 CS � Ceiling: KS1100 CS
French Bakery, Christchurch � New build � Wall: KS1100 CS � Ceiling: KS1100 CS
Coles Distribution, Victoria, Australia� New build � Wall: KS1100 CS � Ceiling: KS1100 CS
Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Ltd and its subsidiary companies do not accept responsibility for errors or for informationthat is found to be misleading. Suggestions for, or descriptions of, the end use or application of products or methods of working are for information only and Kingspan Ltd and itssubsidiaries accept no liability in respect thereof.
I n s u l a t e d Pa n e l s 03/2017
New Zealand: Kingspan Ltd 97 Montreal Street, Christchurch, New Zealand Freephone (0800) 12 12 80 t: +64 (03) 260 5530 f: +64 (03) 260 5539 e: [email protected] www.kingspanpanels.co.nz
For the product offering in other markets please contact your local sales representative or visit www.kingspanpanels.com