Control & Monitoring Systems
Section 5
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Control & Monitoring Systems
Section 5
ControlSystemsareattheheartofthelightingcontrolsystemforanyairfield.TheFederalAvia-tion Administration has set forth standardsdictatinghowfixturesandsignsmaybecontrolledandmonitored.
Crouse-Hindsairfieldcontrol andmonitoringsystemsarede-signedtoprovideprecisioncontrolofairfieldcircuitsandinterfacewithawidearrayofcontrolandmonitoring options.
Lighting Control
Application Icons
5.1
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Section Head
ALCMSAirfield Lighting Control and Monitoring SystemCompliances: FAAAC150/5345-56:L-890 ICAOAnnex14,Vol.1,Para8.3 Transport Canada Aerodrome Standards
ApplicationsTheEatonCrouse-HindsALCMS isETLCertifiedatallfourlevelsofAC150/5345-56.Thisprovidesour Customers with options ranging from abasicsystemwithControlOnlytoacompleteSMGCSsystemforlowvis-ibilityoperation.
TheALCMSisofferedwiththe followingmonitioringoptions:
� ControlOnly � BasicMonitoring � AdvancedMonitoing � SMGCSReady
The ALCMS has the following fail-safeoptions
� Preset State � Last State
Features � ETLCertified � AdvanceddistributedcontrolandmonitoringwithaPCbaseddesigntoprovideanintregratedsolutionforairfieldlightingrequirements.
� Real-timecomprehensivedataoftheairfieldlightingcircuits
� CapableofCATI,II,IIIControl and Monitoring
� SinglelampmonitoringcapabilitywithLogitraclampmonitoringsystem
� RoutingcapabilitywithLogitraclampmonitoringsystem
� Failsafe Design � Flexibleandexpandablesystem
design � Touch-screenControl � Uniquegraphicairfieldlayouts � Softwarethatisdesignedtofit theairportsspecificneeds
� Usersecurityaccess � Definitionandcontroltoolsformain-
tenance, operations, control tower and managment
� Networkredunancyisavailableandisusedforfastreliabledatatransmission
Control & Monitoring Systems
Ordering:ContactEatonCrouse-HindsSalesDepartmenttodiscussourALCMSsystemandrecieve acompletequotationthatmeetstheneedsoftheairportconfiguration.
System Overview:EatonCrouse-HindsprovidesaPC-BasedControlSystemthatisconfigurabletosmall,mediumandlargeairfieldapplicationsthatrequirecontrolandmonitoringofawidearrayofairfield elements.Weworkwithourcustomerstoprovideanauthenticexperiencethatresultsinassimpleorasintricateasystemasdesired.Thesystemisdesignedtoprovidecommandandmonitoringinformationinreal-time,aswellashistoricalinformationonthestatusoftheairfieldlighting. Thecommunicationisaredundantnetworksystemthatusestwohighlyreliableindependent communicationnetworksforfast,reliabledatatransmissions.Thesophisticatedmonitoring capabilitiesindicatewhensystemmonitoredairfieldelementsareoutofcompliance.Thisresults inahighmeantimebetweenfailuresandasystemthatiseasytomaintainandoperate.TheALCMSsystemcancontrolandmonitorstopbars,guardlights,individuallamps,generalelementsandsigns.ThesystemcanalsobedesignedforCATI,IIandIII,offeringroutingcapabilities.
Example of a PC Based Control System
EATON’S CROUSE-HINDS BUSINESS5.2
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
ALCMS ComponentsDigitrac™IntergratedControl&MonitoringTheDigitrac™isadevicethatisintergratedintotheALCMSsystemtocontrolandmonitorCCRs,SelectorSwitchesandGeneralElements(Generators,Windcones,Beacons,RunwayVisualRange{RVR}).
Eachconstantcurrentregulator(CCR)andeachcontrollableelementhasitsownDigitrac™TheDigitrac™isamicroprocessor-basedmod-ule that includes all communication, command, monitoring, input/outputandfail-safefunctions.Thisdistributedstructuresimplifiesin-stallation,significantlyincreasesreliabilityandeaseofmaintenance.Thecontrollableelementsreceivetheairtrafficcontrollercommandsviathecommunicationsnetwork,executethecommandsandreportbackthestatusofeach controlled element to all control locations.
Thesystemcommunicatesinrealtimeallowingairportpersonneltobeawareofthestatusofthelightsontheairfieldatalltimes.TheDigitrac™alsosendsthestatusreportstotheALCMSwhichstoresthe historical information.
Megatrac™InsulationResistanceMonitoringTheMegatrac™isaunitthatperformsinsulationresistance monitoring(meggerteststhe)seriescircuit,allowingthesystemtoautomaticallyormanuallyrunthethetestandreportthe integrityoftheairfieldlightingcircuit.
TheALCMSsystemisusuallydesignedtocommunicatevia powerlinecarrier,sincepowerlinescanloseinsulationquality andthelinecandegradeovertime,wereccommendhaving theMegatracsysteminstalledinsideorneareachCCRThe Megatrac™unithelpsminimizethepossibilityofcommands beinglostbecausethereistoomuchnoiseonthecircuitby monitoringthecircuitintegrity.Thisallowthecustomertime toprepareandrespondtoanypowerlinecircuitconsistancy problems.MaintenancepersonnelcanaccessthedatathroughttheALCMShistoryandmonitorthelongtermintegrityoftheairfieldcircuit.
Ordering Information
Renewal Parts
Description PartNumber
DigitracInterfacePCBoardforFlatPanelT9002-01-22-00DigitracInterfacePCBoard forRackMount/3UIP66 10056-1710MegatracHighVoltageUnit(HVU)110VAC T9006-93-13-00MegatracHighVoltageUnit(HVU)220VAC T9006-93-14-00MegatracPCBoardforRackMount/3UIP66T9006-91-01-00
Enclosure:1500080=IP663UEnclosure
DigitracOptions: 1= DigitracOnly 2 = Digitrac and Megatrac 3= DigitracandDisplayUnit 4= Digitrac,MegatracandDisplayUnit 5= MegatracOnly
RelayOptions: A=NoRelays B=48VDCRelays C=120VACRelays D=24VDCRelays
InputPower: 110 = 110 VAC 220 = 220 VAC
1 5 0 0 0 8 0 - - -
Enclosure:1500167=RackMountEnclosure
DigitracOptions: 0 = 0 Digitracs 1 = 1 Digitrac 2 = 2 Digitracs 3 = 3 Digitracs
MegaTracOptions: A = 1 Megatrac B=2Megatrac C = 3 Megatrac D = 0 Megatrac
RelayOptions: R0=NoRelays R1=48VDCRelays R2=120VACRelays R3=24VDCRelays
1 5 0 0 1 6 7 - - -
Enclosure: 1500061 = Flat Panel Enclosure with MountingPlateandCover
InputPower: NoDash# =120VAC 1 = 220 VAC
1 5 0 0 0 6 1 -
5.3
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
ALCMS ComponentsLogitrac™LampMonitoringSystemTheLogitracLampMonitoringSystemprovidesadvancedcontrolandmoni-toringofstopbarsandguardlightsaspartofaSurfaceMovementGuidanceandControlSystemplanandfailedlamplocatorcapability. TheLampMonitoringSystem(LMS)interactswiththeALCMStocontrolandmonitoraseriesoflightsoreachindividuallighttosupportindependenton,off,orblinkcontrolateachlamp.AdeviceinstalledateachlampknowastheContinousLogitracDevice(CLD)communicatestoandreceivescommandsfromtheALCMSthroughaContinousLogitrac™Adaptor(CLA)typicallylocatedintheairfieldelectricalvault.TheALCMSthenisabletoreceiveanalertmessagewhenaburntoutlamporsensoractivationoccursandprocessthesystemlampstatusestodetermineairfieldcategorycapability(CATI,II,III).ThefailedlamplocatorprovidestheabilitytoensurethattheairportcanmeetthelowvisabilityrequirementsforCATIIandCATIIIoperations.
FiberLogitrac™DeviceIftheairportisusingFiberopticcablinginadditiontopowerlinecarrierthananoptionistheFiberLogitracDevice(FLD).TheFLDcommunicatesviafiberopticlinestoprovideafasterandmoreefficientwayofcontrollingandmonitoringindiviuallamps.WiththeFLDyoucanavoidelectromagneticinterferencefieldissues due to low insulation resistance on the series circuit. The FLD does not re-quireaCLAtocommunicatetotheALCMSsystem.TheFLDhasadatacommu-nicationfasterthan1MbpsensuringafasterresponsetimethatwithastandardsystemTheFLDinstalledateachlampenablesthecontrolandmonitoringofoneortwoleadlampfixtureswhenconnectedbetweenthefixtureandisola-tiontransformer(L830/L831).TheFLDisafullyencapsulateddevicethatisIP68rated to protect against the elements and other damage. The FLD can support fixturesupto400Weach.
Ordering Information
CLD and FLD Configurations
Description PartNumber Description PartNumber
ContinuousLogitracDevice(CLD),2XLAMP,ON/OFF T6540-03-01-00ContinuousLogitracDevice(CLD),2XLAMP,OFF/OFF T6540-03-02-00ContinuousLogitracDevice(CLD),2XLAMP,OFF/OFF,400W T6540-03-03-00ContinuousLogitracDevice(CLD),2XLAMP, ON/OFF,ElevatedRunwayGuardLight T6540-03-04-00ContinuousLogitracDevice(CLD),2XLAMP,ON/ON T6540-03-05-00ContinuousLogitracDevice(CLD),400WSIGNUNIT T6540-03-06-00ContinuousLogitracDevice(CLD),2XLAMP,ON/OFF,400W T6540-03-07-00ContinuousLogitracDevice(CLD),2XLAMP, ON/OFF,InsetRunwayGuardLight T6540-03-08-00ContinuousLogitracDevice(CLD),2XLAMP,ON/ON,LED T6540-03-11-00ContinuousLogitracDevice(CLD),2XLAMP,ON/OFF,LED T6540-03-12-00ContinuousLogitracDevice(CLD),2XLAMP,OFF/OFF,LED T6540-03-13-00ContinuousLogitracDevice(CLD)Programmer T6527-50-01-00FiberOpticLogitracDevice(FLD),2XLAMP,ON/ON T6600-00-01-00FiberOpticLogitracDevice(FLD),2XLAMP,ON/OFF T6600-00-02-00FiberOpticLogitracDevice(FLD),2XLAMP,OFF/OFF T6600-00-03-00
Enclosure: 1500190 = RackMountEnclosure
LogitracOptions: 0 = 0 Logitrac Adapter 1 = 1 Logitrac Adapter 2 = 2 Logitrac Adapter
InputPower: A = 120V B=230V
1 5 0 0 1 9 0 - -
FiberOpticLogitracDevice(FLD), 2XLAMP,ON/ON,50WMAXPERLAMP,LED T6600-00-04-00FiberOpticLogitracDevice(FLD), 2XLAMP,ON/ON,50WMAXPERLAMP,LED T6600-00-05-00FiberOpticLogitracDevice(FLD), 2XLAMP,OFF/OFF,50WMAXPERLAMP,LED T6600-00-06-00FiberOpticLogitracDevice(FLD), 2XLAMP,ON/ON400WMAXPERLAMP T6600-00-07-00FiberOpticLogitracDevice(FLD), 2XLAMP,ON/OFF400WMAXPERLAMP T6600-00-08-00FiberOpticLogitracDevice(FLD), 2XLAMP,OFF/OFF400WMAXPERLAMP T6600-00-09-00FiberOpticLogitracDevice(FLD)Programmer T6600-50-01-00FiberCableforconnectiontoFLD 1500051
Logitrac Device layout examples:
EATON’S CROUSE-HINDS BUSINESS5.4
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
ALCMS ComponentsIndustrialGradeComputersAsperFAAAC150/5345-56allofthecomputersusedinall locationsoftheALCMSsystemareindustrialgradecomputers designed for industrial applications. These computers are much more reliableandhaveagreaterprocessingpowerthannormalcomputer.Itisimportanttohaveareliableindustiralcomputertoensurethattherearenounexpectedandpotentiallydangerousinterruptionstothelightsontheairfield.ThecomputersuseIntel™coreprocessors,havethecapacityforadditionalRAMuseWindowsoperatingsystemwithALCMSsoftwareanddatabase.Allcomputersalsoincludekeyboardandmouse.Mobilecomputerunitsarealsoavailabletocontrolandmonitorthesystemwhile outontheairfield.
UninterruptiblePowerSuppliesItisrecommendthatallcomputercabinetshaveaUPSplaced inside.TheUPSdeliverscontinuous,high-qualityACpowertothe computerequipmentwithoutabreakwhenswitchingtoagenerator. Itprotectstheequipmentfromvirtuallyallpowerdisturbancesdue toblackouts,brownouts,surgesornoiseinterference.TheUPSis capableofsupplyingfullloadpowerforatleast15minutesafter lossofmaininputpower.ThestandardUPSsizesofferedare750VA, 1000VAand2000VAdependingontheamountofequipmentisbeing protectedbytheUPS.
Touchscreen MonitorsTouchscreenstationsaremostcommonlyinstalledinlinewiththetowerdisplaytoallowtheairtrafficcontrollerstoeasilycontroltheairfieldlights.Multiplesizescanbeinstalledinmultiplelocations.EachtouchscreencanshowthewholeALCMSsystemorjustaparticularlocationoftheairfieldorareaoftheALCMSsystem.ThetouchscreensusedaspartoftheALCMSsystemaresunlightreadabletouchscreensmakingthemidealforuseinindustrialaviationapplications,theyalsodonothavefilmsoractivelayerssothesetouchscreensprovideahighclarityimageofthescreen.Touch-screensareavailableinmultiplesizesandcanbemountingintoasurfaceor freestanding.
LCD MonitorsStandardLCDscreensareusuallyinstalledinsideeachcomputercabinet.The computers in the Vault, Operation or the Maintenace Centers are there toenablethestafftomonitor,maintainandpullreportsoftheALCMSsys-tem.Thesemonitorsalsocancomeinvarioussizesaspertheusersrequest.
Nema12RatedComputerEnclosureComputersubsystemishousedinaNema12ratedindustrial enclosure.Thisenclousureprovidesadegreeofprotectionfromdust,dirt,fibersandthewatersuchasdrippingwaterandlightsplashing.Theseenclosurescanbeorderedinvariousconfigurationsaccordingtotheequipmenthousedinside.
Ordering Information
1 5 0 0 4 6 7 - - - - -
Enclosure:1500467=IndustrialGrade Computer
ComputerType: A=RackMount4U B=Desktop
HardwareConfiguration: 1 = Standard 2 = Enhanced
OperatingSystem: A=None C=Windows7,32Bit D=Windows7,64Bit
LonworksOptions: 0=None 1=1PCICard 2=2PCICard 3 = 1 External Ethernet to Echelon Module 4 = 2 External Ethernet to Echelon Module
AdditionalRam: A=None B=4GB
Raided: 0=No 1=Yes
Component Parts
Description PartNumber Description PartNumber
MobileLaptopUnit 1500156UPS,2000VA,120VAC 10056-2191UPS,1000VA,120VAC 10056-2190UPS,750VA,120VAC 10056-189521”LCDTouchscreenMonitor 10056-314019”LCDPanelMountTouchscreenMonitor 10056-254419”BezelforPanelMount TouchscreenMonitor 10056-254517”LCDPanelMountTouchscreenMonitor 10056-305417”BezelforPanelMount TouchscreenMonitor 10056-3055
17”LCDTouchscreenMonitorwithstand10056-227119”LCDMonitor 10056-233717”LCDMonitor 10056-2479Nema12-ComputerEnclosure38U 10056-2532Nema12-ComputerEnclosureSides38U 10056-2549ComputerEnclosureShelf 10056-495Computer Enclosure 12” Deep Shelf 32551ComputerEnclosureKeyboardand MouseDrawer 10056-1437
-
5.5
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
PRO Command ALCMSPLC Based Control and Monitoring SystemCompliances: FAAAC150/5345-56:L-890 ICAOAnnex14,Vol.1 ICAOAerodromeDesignManuel,Part5 Transport Canada Aerodrome Standards
ApplicationsThe PRO command ALCMS isofferedwiththefollowing monitioringoptions:
� ControlOnly
� BasicMonitoring
� AdvancedMonitoing
The ALCMS has the following fail-safeoptions
� Preset State
� Last State
Features � Flexibleandexpandable systemdesign
� Touchscreen Control
� Customgraphicsthatreflect airportlayoutanduserneeds
� Real-timemonitoringof systemwitheventalarms
� EventRecordingforsystem andcircuitanalysis
� Intuitiveuserinterfaceallows foroperatingsystemwithease
� Abilitytoinputusersandlockscreen/transfercontrolwhennecessary
� Fullsystemredundancyavailable
� Fail Safe Feature of Last state orPre-setstateavailable
� Vaultconfigurationscreenfor CCR and circuit changes
� CCRconfigurationscreen
� Photo-cellcontrolisavailable
� Compactsystemdesignallows formoreroominthevault
� Easytoinstallwithstraightforwardsystemlayoutandfewwiringrequire-ments
� Off-the-selfreliableEaton PLC hardware
Control & Monitoring Systems
System Overview:EatonCrouse-Hindsprovidesanairfieldmonitoringandcontrolsystem(ALCMS)usinga EatonProgrammableLogicController(PLC).Thissystemwasdesignedwiththesmallto mediumairfieldorGAAirportinmind.ThePLC-ALCMSisdesignedtoprovidecontroland monitoringofconstantcurrentregulatorsandgeneralairfieldelements.EatonCrouse-Hinds workswithcustomerstoprovideaneaseofdoingbusinessthatresultsinareliableandlong lastingsystemfortheairport.
System Layout Example:
EATON’S CROUSE-HINDS BUSINESS5.6
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Failsafe Options:TypeA-Preset-Uponafailsafecondition, the ALCMS controlled deviceswillswitchtoapre-definedstate(ONtoapre-definedbright-nesslevel,orOFF).
TypeB-LastState-Uponafailsafecondition, the ALCMS controlled devicesmustremainonatthesamebrightnesslevelpriortofailsafecondition.Thefailsafedevicemustmaintain last state (latched) condi-tion.
Control Options:TypeA–ControlOnly.-Thistypeofmonitoringprovidesabasicsystemleveldiagnosticandalarmreport-ing.Thismonitoringleveldoesnotprovidemonitoringorfeedbackforthecontrolledelementsofthesystem(i.e. Constant Current Regulators). The minimumTypeAmonitoringdesigncriteriaisasfollows:Toindicatea“computermalfunction”,“communica-tionlinkwarnings”,“failsafe”,ora“vaultcontrolinterfaceequipmentfailure”.OptionalMonitoring:Toindicatealossofsystemcommercialpowerand/orUPSwarningsandalarms
TypeB–BasicMonitoring.- Thistypeofmonitoringincreasessystemoperationalawarenessandprovidesbasicmonitoringforthecontrolledelements.Thislevelofmonitoringistypicallyrequiredatair-portscapableofoperatinginVFRorCategoryIconditions.TheminimumTypeBmonitoringdesigncriteriaisasfollows:AllmonitoringrequirementsoftheTypeAwiththeadditionoffeedbackthatacontrolledelementisonoroff.Optionalmonitoring:Toindicatealossofsystemcommercialpower,thatthesystemisoperatingongeneratorpowerand/orUPS warnings and alarms.
TypeC–AdvancedMonitoring- This typeofmonitoringexpandsthemoni-toringcapabilitiesforthecontrolledelementsnotprovided intheTypeBmonitoring.Thislevelofmonitoringistypicallyrequired atairportscapableofoperating inCategoryIIandCategoryIII conditions.TheminimumTypeCmonitoring design criteria is as follows:AllmonitoringrequirementsoftheTypeAandTypeBwiththeaddition or CCR monitoring,burntoutlamp monitoring, lamps out threshold warning and alarm,RMS output cur-rentandRMSoutputvoltagemonitor-ing.Optionalmonitoring: Toindicatealossofsystem commercialpower,thatthesystemisoperating on generator power and/or UPSwarningsandalarms.
Ordering Information
Cetification:890G1=L-890, PLCALCMSGen1
FailsafeOptions: A=Pre-Set B=Last-State(Latching)
ControlOptions: A=ControlOnly B=BasicMonitoring C=AdvancedMonitoring
Potential Transformers*NumberofPTsNeeded:CCR≥20kW,6.6ACCR≥20kW,20ACCR<20kW,6.6ACCR<20kW,20A
AirportCode:
ProjectNumber:
*IfyouhaveaCrouse-HindsCCRyoumayalreadyhavethePTinstalledinsidetheregulator
8 9 0 - - - - - - - -
Control & Monitoring Systems
System Configuration Explanations:
5.7
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
HMI (Human Machine Interface) Touchscreen and Enclosure Ordering:
- - P H 1 - - -
TouchscreenType: PH1=HMIandPLCTouchscreenGen1
ScreenSize: A = 12” Touchscreen B =15”Touchscreen C = 21” Touchscreen*
MountingOptions: 0=FlushMount(Noenclosure)withseparate 24”x24”Cabinet,Nema12RatingforWallMount 1=FlushMount(Noenclosure) 2=WallMount/DeskMount(NotNema12Rated) 3=24”x24”CabinetwithNema12Rating,WallMountOnly*
CommunicationSwitchOptions: 0=None(Notneedediflocatedinsame location as a PLC enclosure) 1 = One Communication Line 2 = Two Communication Lines
CommunicationSwitchTypes: A=Multi-mode5portswitch(Reccommendedfor distancesbetweenlocationsoflessthan13,000feet) B=Multi-mode8portswitch(Reccommendedfor distancesbetweenlocationsoflessthan13,000feet andmorethanoneTouchscreen/Monitorisinthevault)) C=Single-mode5portswitch(Reccommendedfor distancesbetweenlocationsofgreaterthan13,000feet) D=Single-mode8portswitch(Reccommendedfor distancesbetweenlocationsofgreaterthan13,000 feetandmorethanoneTouchscreen/Monitorisinthevault)
PowerSupplyOptions**:0=None 1=PowerSupply 2=UninterruptiblePowerSupply3=PowerSupply&UniterruptiblePowerSupply
* If21”touchscreenischosenitcannotbeusedwithmountingoption3 ** Theseoptionscanonlybechosenwithmountingoption3
Control & Monitoring Systems
PRO Command PLC Enclosures:The PRO Command ALCMS systemwillbecomprisedof differentlocationseachwith there own control areas and enclosurecabinetstoensurecontrol/monitoringaccessandcapabilitiesfromall desired airport locations. The following are the ordering and part numberexplainationsthatwill beusedtocustomizethesystem to the airports needs. Please contract a Crouse-HindsSalesorCustomerServiceRepresentativeforhelp with ordering.
EATON’S CROUSE-HINDS BUSINESS5.8
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
General Elements Enclosure Ordering:
TouchscreenType:PGE1=PLCGeneralElementEnclosureGen1ScreenSize: A =None B =12”Touchscreen C = 15” TouchscreenNumberofGeneralElementInputs:InsertQtyabove(Note:Ifgreaterthan16 inputs are needed constact supplier)NumberofGeneralElementstobeControlled:InsertQtyabove
NumberofRVR(RunwayVisualRange)tobeControlled:InsertQtyaboveFailsafeOptions: A =Pre-Set B =Last-State(Latching)Redundancy: 0=None 1 = Redundant CommunicationCommunicationSwitchTypes: A=Multi-mode5portswitch(Reccommendedfor distancesbetweenlocationsoflessthan13,000feet) B=Multi-mode8portswitch(Reccommendedfor distancesbetweenlocationsoflessthan13,000feet andmorethanoneTouchscreen/Monitorisinthevault)) C=Single-mode5portswitch(Reccommendedfor distancesbetweenlocationsofgreaterthan13,000feet) D=Single-mode8portswitch(Reccommendedfor distancesbetweenlocationsofgreaterthan13,000 feetandmorethanoneTouchscreen/Monitorisinthevault)PowerSupplyOptions: 1=PowerSupply 2=UninterruptiblePowerSupply 3=UninterruptiblePowerSupplyandPowerSupplyRedundancy
Control & Monitoring Systems
PRO Command PLC Enclosures:The PRO Command ALCMS systemwillbecomprisedof differentlocationseachwith there own control areas and enclosurecabinetstoensurecontrol/monitoringaccessandcapabilitiesfromall desired airport locations. The following are the ordering and part numberexplainationsthatwill beusedtocustomizethesystem to the airports needs. Please contract a Crouse-HindsSalesorCustomerServiceRepresentativeforhelp with ordering.
P G E 1 - - -- - - - -
*TouchscreenisoptionalonPGE1Enclosure
5.9
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Vault Enclosure Ordering:
TouchscreenType: PV1 = PLC VaultEnclosureGen1ScreenSize: A =8.4”Touchscreen&PLC B =5.7”Touchscreen&PLCNumberofCCRs*:InsertQtyabove
Numberof3orLessBrightnessStepCCRswithoutCircuitSelectorSwitches: InsertQtyaboveTotalNumberofGeneralElement andSelectorSwitchPoleInputs**:InsertQtyabove(Upto32Inputs)NumberofGeneralElementstobeControlled**:InsertQtyabove(Upto8elements)Enclosure: A=24”x24”Nema12Enclosure B=36”x36”Nema12Enclosure(Requiredforunitswith>8CCRs)FeedbackType: 0=None 1=On/Off 2 = Current/Voltage MeasurementFailsafeOptions: A=Pre-Set B=Last-State(Latching)Redundancy: 0=None 1 = Redundant PLC 2 = Redundant Communication 3 = Redundant PLC and CommunicationCommunicationSwitchTypes: A=Multi-mode5portswitch(Recommendedfor distancesbetweenlocationsoflessthan13,000feet) B=Multi-mode8portswitch(Recommendedfor distancesbetweenlocationsoflessthan13,000feet andmorethanoneTouchscreen/Monitorisinthevault)) C=Single-mode5portswitch(Recommendedfor distancesbetweenlocationsofgreaterthan13,000feet) D=Single-mode8portswitch(Recommendedfor distancesbetweenlocationsofgreaterthan13,000 feetandmorethanoneTouchscreen/Monitorisinthevault)PowerSupplyOptions: 1=PowerSupply 2=UninterruptiblePowerSupply 3=UninterruptiblePowerSupplyandPowerSupplyRedundancy
* IftotalnumberofCCRaregreaterthan24,contactthesupplierformoreoptions. ** Ifqtyisoversuggestedamountthenacustomconfigurationisneeded,contact the supplier for more options.
- - -- - - - -
Control & Monitoring Systems
P V 1 - - -
EATON’S CROUSE-HINDS BUSINESS5.10
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se
Vault Enclosure Outline Examples of Touchscreen Graphic Layouts
5.11
www.crouse-hinds.com/airportlighting Home Office: United States – +1 860-683-4300International Offices: Canada • China • Dubai • Mexico • Brazil
CHS Controls AB Tel +46 42 38 61 00, Fax +46 42 38 61 29 [email protected] www.chscontrols.se