Consiglio Nazionale delle Ricerche 3 rd COPS and GOP workshop 10-11 April 2006 Consiglio Nazionale...
-
Upload
carissa-sax -
Category
Documents
-
view
217 -
download
0
Transcript of Consiglio Nazionale delle Ricerche 3 rd COPS and GOP workshop 10-11 April 2006 Consiglio Nazionale...
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Consiglio Nazionale delle Ricerche
Istituto di Metodologie per l’Analisi Ambientale
CNR-IMAATito Scalo (Potenza) Italy
Aldo Amodeo
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
•Gelsomina Pappalardo•Aldo Amodeo•Antonella Boselli•Lucia Mona•Marco Pandolfi•Giuseppe D’Amico•Carmela Cornacchia
•PhD students•Fabio Madonna
CNR-IMAA lidar group
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
IMAA ground based facility for Earth ObservationIMAA ground based facility for Earth Observation
Aerosol lidarAerosol lidarWater vapour Raman lidarWater vapour Raman lidarMobile DIAL systemMobile DIAL systemMicrowave radiometer 12 channelsMicrowave radiometer 12 channelsRadiosounding (P,T, RH, ORadiosounding (P,T, RH, O33 and wind) RS92 Vaisala and wind) RS92 Vaisala
CIMEL sunphotometerCIMEL sunphotometerCEILOMETER (VAISALA CT25K)CEILOMETER (VAISALA CT25K)
NextNextMobile Aerosol Raman lidarMobile Aerosol Raman lidarMobile Water Vapor Raman lidarMobile Water Vapor Raman lidar
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
IMAA ground based facility for Earth ObservationIMAA ground based facility for Earth Observation
Aerosol lidarAerosol lidarWater vapour Raman lidarWater vapour Raman lidarMobile DIAL systemMobile DIAL systemMicrowave radiometer 12 channelsMicrowave radiometer 12 channelsRadiosounding (P,T, RH, ORadiosounding (P,T, RH, O33 and wind) RS92 Vaisala and wind) RS92 Vaisala
CIMEL sunphotometerCIMEL sunphotometerCEILOMETER (VAISALA CT25K)CEILOMETER (VAISALA CT25K)
NextNextMobile Aerosol Raman lidarMobile Aerosol Raman lidarMobile Water Vapor Raman lidarMobile Water Vapor Raman lidar
Possible involvmentin COPS
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
MW RADIOMETER TP-WVP 3000BRIGHTNESS TEMPERATURE(12 channels, 5 in K-Band 22.2÷30 GHz and 7 in V-Band 51.3÷58.8 GHz)
Zenith acquisition
Acquisition time5 minutes
PRODUCTS
Temperature profileVertical resolution:0÷1 Km, 100m / 1÷10 Km, 250mAccuracy: 0.5 K
Water vapor and RH profilesVertical resolution:0÷1 Km, 100m / 1÷10 Km, 250m
Liquid water profileVertical resolution:0÷1 Km, 100m / 1÷10 Km, 250m
Ground parameterspressure, temperature, RH
Integrated quantitieswater vapor, liquid water
Other parameterscloud base (IRT)
MW RADIOMETER TP-WVP 3000BRIGHTNESS TEMPERATURE(12 channels, 5 in K-Band 22.2÷30 GHz and 7 in V-Band 51.3÷58.8 GHz)
Zenith acquisition
Acquisition time5 minutes
PRODUCTS
Temperature profileVertical resolution:0÷1 Km, 100m / 1÷10 Km, 250mAccuracy: 0.5 K
Water vapor and RH profilesVertical resolution:0÷1 Km, 100m / 1÷10 Km, 250m
Liquid water profileVertical resolution:0÷1 Km, 100m / 1÷10 Km, 250m
Ground parameterspressure, temperature, RH
Integrated quantitieswater vapor, liquid water
Other parameterscloud base (IRT)
MICROWAVE RADIOMETER(Radiometrics mod. TP-WVP 3000)
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
MICROWAVE RADIOMETER MEASUREMENTS
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
IMAA CNR lidar and MW radiometerWater vapor column content
18.51 20.31 22.11 23.51 1.31 3.110.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
9 September 2004CNR-IMAA Tito Scalo
4.2117.12
Wat
er v
apou
r co
lum
nar
cont
ent
(cm
)
Time (UT)
Radiometer Lidar
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Relative humidity obtained from CNR-IMAA MW radiometer
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Comparison between Integrated Precipitable Water vaporobtained from CNR-IMAA MW radiometer and Radiosounding system
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
0
1
2
3
4
5
6
-1 0 1 2 3 4 5 6 7 8 9 10
Lidar 00:30-00:40 UT Sonde start 00:35 UT Radiometer 00:30-00:40 UT
QH
eigh
t a.
s.l.
(km
)
Water vapour mixing ratio (g/kg)
0
1
2
3
4
5
6
7
8
9
10
0.01 0.1 1 10
QH
eigh
t a.
s.l.
(km
)
Water vapour mixing ratio (g/kg)
0
1
2
3
4
5
6
7
8
9
10
200 220 240 260 280 300
Sonde 00:35 UT Radiometer 00:30-00:40 UT
Hei
ght
a.s.
l. (k
m)
Temperature (K)
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70 80 90 100
Radiometer 00:30-00:40 UT Lidar + radiometer 00:30-00:40 UT Lidar + sonde 00:30-00:40 UT Sonde 00:35 UT
Hei
ght
a.s.
l. (k
m)
Relative Humidity (%)
CNR-IMAA Tito Scalo 10 September 2004
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Data typology from MW Radiometer
Level 0: raw data and all configuration, calibration and measurements parameters to reprocess the data.
Level 1: sky brightness temperature and surface meteorological parameters.
Level 2: temperature, water vapour and liquid water profiles and surface meteorological parameters.
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Other lidar instrumentation available at IMAA
Two operational lidars:
Aerosol lidar: detected wavelengths (nm) : 355, 532, 1064, 386, 607, depolarization ratio at 532
backscatter at 355, 532, and 1064 nmextinction at 355 and 532 nmdepolarization ratio at 532 nm
Water vapour lidar: detected wavelengths (nm): 355, 386, 407backscatter at 355 nmextinction at 355 nmwater vapour mixing ratio
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Aerosol lidarBackscatterRange: 500-30000 m in night-time conditions 500-10000 m in daytime
conditionsResolution: 60 m and 10 min in night-time conditions,
ExtinctionRange: 500-7000 m in night-time conditions 500-3000 m in daytime conditionsResolution: 150 m in 500-7000 m and 10 min in night-time conditions
150 m in 500-3000 m and 30 min in daytime conditions
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Water vapour lidar
Range: 90-12000 m in night-time conditions90-4000 m in daytime conditions
Resolution: 15 m up to 6000 m and 150 m above in night-time conditions,10 min time integration
15 m in daytime conditions30 min time integration
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Water vapour Raman lidar
Aerosol Raman lidar
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Future instrumentation to be used in COPS
By the middle of 2007, two mobile lidars will be available:
Mobile Raman detected wavelengths (nm) : 355, 532, 1064, 386, 607, Aerosol lidar: depolarization ratio at 532
backscatter at 355, 532, and 1064 nmextinction at 355 and 532 nmdepolarization ratio at 532 nm
Mobile Water detected wavelengths (nm): 355, 386, 407Vapour Raman lidar: backscatter at 355 nm
extinction at 355 nmwater vapour mixing ratio
ConsiglioNazionaledelle Ricerche 3rd COPS and GOP workshop 10-11 April 2006
Data typology provided
Mobile Raman Aerosol lidarLevel 0: range corrected signal, not calibrated depol. Ratio, cloud thickness;
Level 1: aerosol extinction and backscatter, optical depth, calibrated depol ratio,cloud optical depth;
Level 2: aerosol microphysical properties;
Mobile Water Vapour Raman lidarLevel 0: water vapour mixing ratio not calibrated;
Level 1: water vapour mixing ratio corrected for overlap function, extinction and temperature;
Level 2: water vapour mixing ratio calibrated;