Connect and engage innovation - Vingmed A/S
Transcript of Connect and engage innovation - Vingmed A/S
2
CONNECT Manager
The Heartlink card, linking Perfusion system components together
Rely on GDP Monitor for real time calculation of DO2, VO2 and VCO2 parameters
Quality Scores holds the key to understanding valuable trends in the Perfusion practice
CONNECT Recorder
Electronically link Sorin ATS devices and Connect to integrate all Perfusion data into one case record
Visualize the hemodilution footprint with the dedicated fluid balance chart
Customization brings focus to interventions
2 Connect applications Page 4
4 Connect the missing links Page 6
3 Designed with Goal Directed Perfusion in Mind Page 5
1 Connect operating concept Page 3
5 Post Case Reporting Page 7
6 Statistics - Turning data into information Page 7
Index
3
CONNECT and ENGAGE: Innovative real Time Data Calculation, Trending and Monitoring
The CONNECT electronic charting system allows for collection of all clinical and patient data during cardiopulmonary bypass cases via the Recorder application. During the surgical case, the Recorder application contains valuable trending and monitoring tools allowing the Perfusionist to view real time patient and case date updated every 10 seconds. The Perfusionist may view data in the forms of graphs or charts according to their preference. Also included is information relative to case times, use of safety devices, warning limits and alarms for the heart lung machine, fl uid balance, cardioplegia, gas fl ow, blood gas, coagulation and perfusion formula calculations. The CONNECT system may also be confi gured to collect data electronically from a variety of patient monitors, blood gas devices, ACT meters, and cerebral oximetry devices. The Perfusionist has the ability to manually enter any of the above data as well as add comments and event entries necessary for complete documentation during the case. After the case, the electronic chart is exported
from the Recorder to the Manager application where the Pefusionist may choose to print the record, export via PDF or excel formats and commit the case to the main database. Once commited to the Manager database, the case may be accessed at anytime for printing or export. Cases in the database may also be selected for statistical and inventory analysis and reports.
1 CONNECT operating concept
4
CONNECT Manager:
• Maintains valuable Perfusion data and case records at the fi ngertips of the Perfusion group
• Print a patient record or utilize one of the export options to comply with the hospital patient record needs
• Utilize the included statistics module for clinical queries or inventory report needs
2 CONNECT applications
CONNECT Recorder:
• Bid goodbye to outdated charting systems and welcome CONNECT Recorder for an innovative and intuitive electronic record experience
• Electronically importing hundreds of values from the heart lung machine and other devices in the OR improves the frequency and quantity of data documentation
• Quick and easy manual event entry works together with electronic data capture to ensure a complete picture of the Perfusion case
5
Rely on GDP Monitor for real time calculation of DO2, VO2 and VCO2 parameters
Visualize the hemodilution footprint with the dedicated fl uid balance chart
The embedded Quality Scores feature holds the key to understanding valuable trends in the Perfusion practice
3 Designed with Goal Directed Perfusion in Mind
Events
• Data may be collected electronically or manually entered to achieve calculation results
• A graphical view or data table is available and fully customizable according to viewing preferences
• Assign your choice of parameters for tracking and monitoring Perfusion or patient physiological data points during CPB
• Select the minimum and maximum range that meets the Perfusion groups goals for patient care and practice improvement goals
• For assessment and management of your gain/loss goals, quickly reference the graphical trend of volumes given to and removed from the patient
• Refer to the detailed input/output for a closer look at the volume trend
• Choose which events are displayed for monitoring and trending to help focus on practice and patient improvement goals
• Customize event labels and colors to visually highlight event entries and interventions during the case
6
The Heartlink card, linking Perfusion system components together
4 CONNECT the missing links
Electronically link Sorin ATS devices and Connect to integrate all Perfusion data into one case record
• After ATS processing is complete, quickly and effortlessly export all ATS data into the Perfusion patient record
• Ensure integrity of the ATS data and continuity of one reporting system to help meet your reporting and statistical goals
• Instantaneous transmission of detailed disposable product information to effi ciently document data and support data integrity efforts
• Reach new levels on product traceability through the Heartlink card functionality and inventory report capability embedded within the CONNECT Manger statistics program
7
View the patient record for analysis post case or print a paper copy for inclusion with the patient hospital medical record
Export a PDF copy of the perfusion patient record to a local drive and/or a hospital network drive
The included Statistics package allows database searches based on clinical or product focus
6 Statistics - Turning data into information
• Apply query fi lters and print the results for a one time query interest or save the template for recurring query needs
• Export case data of the query results to PDF or CSV fi les for further reporting and analysis needs or wishes
The embedded reporting program includes multiple modes for flexible report handling
5 Post Case Reporting
0929
5-11
3 -
Bro
chur
e no
t for
US
Contacts:Sorin Group Italia S.r.l.Via Statale 12 Nord, 8641037 Mirandola (MO) ItaliaTel.: +39.0535.29811Fax: [email protected]
Manufacturer:Sorin Group Deutschland GMBHLindbergstrasse 25D-80939 München GermanyTel: +49.(0)89.32301.0Fax: +49.(0)89.32301.555
order guide
Identifi cation code Description Quantity / Box
SORIN CONNECT RECORDER 24-90-30 for S5 1SORIN CONNECT RECORDER 24-90-31 for S3 1SORIN CONNECT MANAGER 24-90-45 1
Additional packages for upgrades from DMS are available, please contact your local Sorin Group Representative for more details.
SPECIFICATIONS:
CONNECT MANAGER
Operating system: Microsoft® Windows® XP service pack 3 / Microsoft® Windows® 7
Random access memory (RAM): 1 GB (recommended)
Screen resolution: 1024 x 768 pixels
Database used: Microsoft® SQL Server 2008 R2 Express (recommended)
Free hard disk space - software: 120 MB / Microsoft® SQL Server 2008 R2
Express database: 12 GB
DATAPAD FOR CONNECT RECORDER
Operating system: Microsoft® Windows® XP Professional
Intel® CoreTM 2 Duo processor
SO-DIMM DDR1-RAM 2 GByte
1x COM Port (COM1), TTL Level
2x PS/2 Ports for Keyboard and Mouse
4x USB 2.0 Ports (EHCI)
1x IEEE 802.3u 100Base-Tx Fast Ethernet compatible Port
WLAN MODULE SPECIFICATIONS
Frequency Range: 2.400 – 2.483 GHz, 5.15 – 5.35 GHz, 5.725 – 5.825 GHz
Modulation Technique: OFDM; DSSS
Operation System Supported: Microsoft® Windows® XP
Security 64-bit, 128-bit, 152-bit WEP Encryption
802.1 Authentication
AES-CCM & TKIP Encryption
Wi-Fi Alliance WECA Compliant
WHQL Microsoft XP Compliant
Media Access Protocol CSMA/CA with ACK architecture 32-bit MAC
Antenna connector 2xSMT Ultra-miniature coaxial connectors