Confidential Confidential Confidential · 2019-03-23 · 2018, Data Panel, Corp. Confidential...
Transcript of Confidential Confidential Confidential · 2019-03-23 · 2018, Data Panel, Corp. Confidential...
2018, Data Panel, Corp.
Confidential Confidential Confidential
LCD Display Screen and CAN Control
Document Control No. 33026-805 Rev J
15 March 2019
____________________________
This document is the exclusive property of Data Panel Corporation. Any reproduction of this document without permission is prohibited
DOCUMENT REVISION HISTORY
Rev DCN Date Description F E639 08 Nov 18 Update Screens
G E691 27 Dec 18 Add four Warning Screens
H E769 22 Feb 19 Add Input Output Screens
J E798 15 Mar 19 Add Screen 63, Remove Load King
Data Panel Corporation 181 Cheshire Lane, Suite 300
Plymouth, MN 55441 Phone: 952.941.3511
Fax: 952.941.3931
2018, Data Panel, Corp.
REVISION HISTORY
A: 11 February 2014
a. Eng Draft: Copied from 30038-807N. b. Par 2.3 Made status screens CD4 and CD5 only. Removed CD2.
B: 22 April 2014
a. Title Page Updated revision history. b. Par 1.1 Change software revision required. c. Par 2.3 Added Screen 19 for Compartments Open. d. Par 2.3 Added Screen 22 new series INFO for Master Switch.
C: 21 November 2014
a. Title Page Updated revision history and date. b. Par I & II Update warranty and License Disclaimer. c. Par 1.1 Change software revision required. d. Screen 14 Change wording.
D: 12 August 2016
a. Title Page Updated revision history and date. b. Title Page Update address. c. Par 2.0 Switched 2.1 and 2.2. Added summary list.
E: 26 April 2018
a. Title Page Updated revision history and date. b. Par 7 Removed Priority and SA from CD1 to CD7.
F: 08 October 2018
a. Title Page Updated revision history and date. b. Par 2.2 Update screen summary list. c. Par 2.3 Added screen 23. d. Par 2.3 Added screen 24. e. Par 2.3 Added screen 55, 56, 60, and 61. f. Par 2.3 Added screen 62. g. Par 7.2 Update CD1 message.
G: 22 December 2018
a. Title Page Updated revision history and date. b. Par 2.2 Added screen 27 – 30.
H: 22 February 2019
a. Title Page Updated revision history and date. b. Par 2.2 Added Screens 31, 32, 33: Input, Relay, Output Screen c. Par 2.2 Added Screens 80: Load King Logo Screen
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 1
J: 15 March 2019
a. Title Page Updated revision history and date. b. Par 2.2 Removed Screens 31, 32, 33 and 80 c. Par 2.2 Moved Screen 52 to 51 d. Par 2.2 Add Screen 63
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 2
TABLE OF CONTENTS
1.0 OVERVIEW ................................................................................................................................................ 3
1.1 PROJECT SCOPE: SWITCH PANEL ....................................................................................................... 3
2.0 DISPLAY .................................................................................................................................................... 3
2.1 SUPPORTED CHARACTERS ................................................................................................................... 3
2.2 SCREEN SUMMARY ................................................................................................................................. 4
2.3 DISPLAY SCREENS ................................................................................................................................. 6
7.0 APPENDIX A: CAN MESSAGE CONTROL AND OPERATION ........................................................... 28
7.1 CAN CONTROL AND OPERATION MESSAGE SUMMARY TABLE ................................................... 28
7.2 CHARACTER DISPLAY MESSAGE [CD1] CONTROL MESSAGE (PGN 65385) ................................ 29
7.3 CHARACTER DISPLAY MESSAGE [CD2] CONTROL MESSAGE (PGN 65386) ................................ 31
7.4 CHARACTER DISPLAY MESSAGE(S) [CD3] CONTROL MESSAGE (PGN 65387) ........................... 32
7.5 INPUT STATUS MESSAGE [CD4] CONTROL MESSAGE (PGN 65388) ............................................. 33
7.6 OUTPUT STATUS W/ FAULTS MESSAGE [CD5] CONTROL MESSAGE (PGN 65389) .................... 34
7.7 OUTPUT STATUS TBD MESSAGE [CD6] CONTROL MESSAGE (PGN 65390) ................................ 35
7.8 CHARACTER DISPLAY MESSAGE(S) [CD7] CONTROL MESSAGE (PGN 65391) ........................... 36
APPENDIX A SUPPORTED ASCII CODES (1 OF 3) .................................................................................. 37
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 3
1.0 Overview The 33026 is a DPLogic Certified 16 Pos Switch Panel. Using mcdpxTM style switches with a backlit LCD display.
1.1 Project Scope: Switch Panel This document establishes the design requirements for the graphical portion of the LCD display. The display module is used in the 29036 and 33026 switch panel.
2.0 Display
a. The display shall be a monochrome dot matrix LCD Display. b. The display shall have a dot format of 128 x 64. c. The display is LED backlit. The LED color shall be White. d. The display is Transflective style. e. The display shall have an operating temperature of -20C to +70C.
2.1 Supported characters CD3 supports a subset of the ASCII character set. ASCII Characters 0 to 9 are replaced by ASCII Characters 48 - 57. Example: Sending a “1” will draw “1” verses sending “49” to draw “1”. This is intended to simplify displaying numeric values ASCII Characters 32 to 95 are supported. This allows uppercase A – Z, numeric values 0-9 and several special characters. Digital Output Status Bit Pairs shall follow the format below for all message response.
Digital Output Status Bit Pairs 00 = OFF / FALSE 01 = ON / TRUE
10 = FAULT 11 = NOT USED
See Appendix B for a complete listing.
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 4
2.2 Screen Summary
a. The default screen displayed will be 255 until the message CD1 is received. b. If the LC1 message times out, Screen 252 will be displayed. c. If the CD1 message times out, Screen 253 will be displayed.
Screen Index 0 – CLEAR SCREEN Screen Index 1 – VER.REV SCREEN Screen Index 2 – HOURS 1 PTO / ENG Screen Index 3 – INPUT 1 - 12 Screen Index 4 – INPUT 13 - 24 Screen Index 5 – OUTPUT 1 - 12 Screen Index 6 – OUTPUT 13 - 24 Screen Index 7 – WARNING 1 BOOM STOW Screen Index 8 – WARNING 2 OUTRIGGERS Screen Index 9 – HOURS 2 BOOM Screen Index 10 – WARNING 3 RADIO STOW Screen Index 11 – HOURS 3 PTO Screen Index 12 – WARNING 4 COMMAND POST Screen Index 13 – WARNING 5 NODE TEMP Screen Index 14 – WARNING 6 OUTPUT FAULT Screen Index 15 – WARNING 7 BATTERY VOLTAGE < 11.7 VDC Screen Index 16 – WARNING 8 CAB DOORS Screen Index 17 – WARNING 9 CS COMPARTMENT Screen Index 18 – WARNING 10 SS COMPARTMENT Screen Index 19 – WARNING 11 COMPARTMENTS Screen Index 20 – OUTPUT 3 RELAY K1 – K12 Screen Index 21 – OUTPUT 4 RELAY K13 – K14 Screen Index 22 – INFO SCREEN 1 MASTER SWITCH Screen Index 23 – HOURS 4 CRANE / COMPRESSOR Screen Index 27 – WARNING 12 EMERGENCY STOP Screen Index 28 – WARNING 13 BATTERY VOLTAGE < 11.0 VDC Screen Index 29 – WARNING 14 HIGH OPERATING PRESSURE Screen Index 30 – WARNING 15 A2B SWITCH Screen Index 50 – PSI 1 AUX / PROPELLANT Screen Index 51 – PSI 2 (Spanish) Screen Index 54 – Analog Inputs Screen Index 55 – Analog A and Analog B Screen Index 60 – Frequency and Duty Cycle Screen Index 61 – Count and Set Point Screen Index 62 – Climate Control and Volt Meter FSP and RSP Screen Index 63 – Flow Rate GPM
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 5
Screen Index 80 – DP LOGO SCREEN Screen Index 250 – DIAGNOSTICS 0 SELF TEST RUN Screen Index 251 – DIAGNOSTICS 1 SELF TEST OK Screen Index 252 – DIAGNOSTICS 2 NO LC1 MESSAGE Screen Index 253 – DIAGNOSTICS 3 NO CD1 MESSAGE Screen Index 254 – FAULT SYSTEM Screen Index 255 – TEST PATTERN
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 6
2.3 Display Screens Screens are displayed by writing the screen index to CD1, b0. Screen Index 0 – CLEAR SCREEN
Screen Index 1 – VER.REV SCREEN
{data group 1} [CD1] PGN 65385 control byte #2 {data group 2} Controlled local by node: 33026-560-vvrr
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 7
Screen Index 2 – HOURS 1
{data group 1} [CD7] PGN 65391 5 characters 16 Bit #1 [CD7] PGN 65391 1 character decimal #1 {data group 2} [CD7] PGN 65391 5 characters 16 Bit #2 [CD7] PGN 65391 1 character decimal #2 Screen Index 3 – INPUT 1
{bp 1 – bp 12} [CD4] PGN 65388 00: OFF 01: ON
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 8
Screen Index 4 – INPUT 2
{bp 13 – bp 24} [CD4] PGN 65388 00: OFF 01: ON Screen Index 5 – OUTPUT 1
{bp 1 – bp 12} [CD5] PGN 65389 00: OFF 01: ON 10: FAULT
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 9
Screen Index 6 – OUTPUT 2
{bp 13 – bp 24} [CD5] PGN 65389 00: OFF 01: ON 10: FAULT Screen Index 7 – WARNING 1
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 10
Screen Index 8 – WARNING 2
Screen Index 9 – HOURS 2
{data group 1} PGN 65391 5 characters 16 Bit #1 PGN 65391 1 character decimal #1
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 11
Screen Index 10 – WARNING 3
Screen Index 11 – HOURS 3
{data group 1} PGN 65391 5 characters 16 Bit #1 PGN 65391 1 character decimal #1
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 12
Screen Index 12 – WARNING 4
Screen Index 13 – WARNING 5
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 13
Screen Index 14 – WARNING 6
Screen Index 15 – WARNING 7
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 14
Screen Index 16 – WARNING 8
Screen Index 17 – WARNING 9
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 15
Screen Index 18 – WARNING 10
Screen Index 19 – WARNING 11
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 16
Screen Index 20 – OUTPUT 3
{bp 1 – bp 12} [CD6] PGN 65390 00: OFF 01: ON Screen Index 21 – OUTPUT 4
{bp 13 – bp 24} [CD6] PGN 65390 00: OFF 01: ON
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 17
Screen Index 22 – INFO SCREEN 1
Screen Index 23 – HOURS 4
AIR COMP HRS:
CRANE HRS: 12345.6
12345.6
{data group 1}
{data group 2}
{data group 1} [CD7] PGN 65391 5 characters 16 Bit #1 [CD7] PGN 65391 1 character decimal #1 {data group 2} [CD7] PGN 65391 5 characters 16 Bit #2 [CD7] PGN 65391 1 character decimal #2
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 18
Screen Index 27 – WARNING 12
EMERGENCY STOP
WARNING
Screen Index 28 – WARNING 13
BATTERY VOLTAGE < 11.0 VDC
WARNING
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 19
Screen Index 29 – WARNING 14
HIGH OPERATINGPRESSURE
WARNING
Screen Index 30 – WARNING 15
A2B SWITCH
WARNING
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 20
Screen Index 50 – PSI 1
{data group 1} [CD7] PGN 65391 5 characters 16 Bit #1 [CD7] PGN 65391 1 character decimal #1 {data group 2} [CD7] PGN 65391 5 characters 16 Bit #2 [CD7] PGN 65391 1 character decimal #2 Screen Index 51 – PSI 2 (Spanish)
{data group 1} [CD7] PGN 65391 5 characters 16 Bit #1 [CD7] PGN 65391 1 character decimal #1 {data group 2} [CD7] PGN 65391 5 characters 16 Bit #2 [CD7] PGN 65391 1 character decimal #2
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 21
Screen Index 54 – Analog Inputs
{data group 1} [CD2] PGN 65386 (10 Bit Value) Vdc / Bit = {data group 2} [CD2] PGN 65386 (10 Bit Value) Vdc / Bit = {data group 3} [CD2] PGN 65386 (10 Bit Value) Vdc / Bit = {data group 4} [CD2] PGN 65386 (10 Bit Value) Vdc / Bit = Screen Index 55 – Analog A and Analog B
ANALOG B:
ANALOG A:
65535
{data group 2}65535
{data group 1}
{data group 1} [CD7] PGN 65391 Byte 1 and Byte 2 {data group 2} [CD7] PGN 65391 Byte 4 and Byte 5
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 22
Screen Index 60 – Frequency and Duty Cycle
DUTY CYCLE:
FREQUENCY: 65535
65535
{data group 1}
{data group 2}
{data group 1} [CD7] PGN 65391 Byte 1 and Byte 2 {data group 2} [CD7] PGN 65391 Byte 4 and Byte 5 Screen Index 61 – Count and Set Point
SET POINT:
COUNT: 65535
65535
{data group 1}
{data group 2}
{data group 1} [CD7] PGN 65391 Byte 1 and Byte 2 {data group 2} [CD7] PGN 65391 Byte 4 and Byte 5
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 23
Screen Index 62 – Front Switch Panel
SHORELINE:
BATTERY: 14.5
ON
{data group 1}
{data group 2}
{data group 1} [CD1] PGN 65385 Byte 4 {data group 2} [CD1] PGN 65385 Byte 3, Bit Pair 3 Displayed when Address offset = 0 Screen Index 62 – Rear Switch Panel
FAN:
TEMPERATURE: 72 F
AUTO
{data group 1}
{data group 3}
PSI: 5000
{data group 2}
{data group 1} [CD1] PGN 65385 Byte 5 {data group 2} [CD1] PGN 65385 Byte 6 and Byte 7 {data group 3} [CD1] PGN 65385 Byte 3, Nibble 1 Displayed when Address offset = 1
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 24
Screen Index 63 – Flow Rate GPM
1 2 3 4
GPM/LPM
{data group 2}
{data group 1}
{data group 1} [CD1] PGN 65385 Byte 3 and Byte 4 {data group 2} [CD1] PGN 65385 Byte 6 bit pair 1 Screen Index 80 – LOGO SCREEN
Data Panel
SYSTEM: vv.rr VV.RR
{data group 2}{data group 1}
{data group 1} PGN 65385 control byte #2 {data group 2} Controlled local by node: 33026-560-vvrr
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 25
Screen Index 250 – DIAGNOSTICS 0
Screen Index 251 – DIAGNOSTICS 1
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 26
Screen Index 252 – DIAGNOSTICS 2
Screen Index 253 – DIAGNOSTICS 3
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 27
Screen Index 254 – FAULT
{data group 2} PGN 65391 5 characters 16 Bit #2 Screen Index 255 – TEST PATTERN
Note: Diagnostic information shown above may change.
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 28
7.0 Appendix A: CAN Message Control and Operation 7.1 CAN Control and Operation Message Summary Table
Description Function PGN SA
Character Display Message [CD1] Screen Mode 65385 (0xFF69) n/a
Character Display Message [CD2] Screen Data 65386 (0xFF6A) n/a
Character Display Message [CD3] Characters 65387 (0xFF6B) n/a
Character Display Message [CD4] Input Status 65388 (0xFF6C) n/a
Character Display Message [CD5] Output Status 65389 (0xFF6D) n/a
Character Display Message [CD6] Relay Status 65390 (0xFF6E) n/a
Character Display Message [CD7] Hours 65391 (0xFF6F) n/a
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 29
7.2 Character Display Message [CD1] Control Message (PGN 65385)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 105 0x69
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65385 8 7 6 5 4 3 2 1
Byte 1 7 6 5 4 3 2 1 0 Control Byte 1 Control Bit Pair 1
Byte 2 7 6 5 4 3 2 1 0 Control Byte 2 Control Bit Pair 2
Byte 3 7 6 5 4 3 2 1 0 Control Byte 3 Control Bit Pair 3
Byte 4 4 4 4 4 3 2 1 0 Control Byte 4 Control Bit Pair 4
Byte 5 4 4 4 4 3 2 1 0 Control Byte 5 Control Bit Pair 5
Byte 6 d4 d4 d3 d3 d2 d2 d1 d1 Control Bit Pair 6
Byte 7 d8 d8 d7 d7 d6 d6 d5 d5 Control Bit Pair 7
Byte 8 7 6 5 4 3 2 1 0 Control Bit Pair 8
Control Byte 1: Screen Selection Control Byte 2 – Byte 8: Defined by screen function. See specific screen
Screen 1: Byte 2 User defined version and revision. Screen 80: Byte 2 User defined version and revision. Screen 62:
PGN 65385 8 7 6 5 4 3 2 1 Byte 1 7 6 5 4 3 2 1 0 Screen Mode
Byte 2 7 6 5 4 3 2 1 0 Ver, Rev
Byte 3 d4 d4 d3 d3 3 2 1 0 Fan
Byte 4 7 6 5 4 3 2 1 0 Shore Power
Byte 5 7 6 5 4 4 3 2 1 Spare
Byte 6 7 6 5 4 3 2 1 0 Voltage
Byte 7 15 14 13 12 11 10 9 8 Temperature
Byte 8 1 1 1 1 1 1 1 1 PSI
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 30
Screen 63:
PGN 65385 8 7 6 5 4 3 2 1 Byte 1 7 6 5 4 3 2 1 0 Screen Mode
Byte 2 7 6 5 4 3 2 1 0 Ver, Rev
Byte 3 7 6 5 4 4 3 2 1 Gauge #4
Byte 4 15 14 13 12 11 10 9 8 GPM or LPM
Byte 5 1 1 1 1 1 1 1 1
Byte 6 d24 d24 d23 d23 d22 d22 d21 d21
Byte 7 1 1 1 1 1 1 1 1
Byte 8 1 1 1 1 1 1 1 1 Byte 3 : Gauge #4 Word Data Range [0 : 9999] [d21] : 0x00b – GPM 0x01b – LPM
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 31
7.3 Character Display Message [CD2] Control Message (PGN 65386)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 106 0x6A
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65386 8 7 6 5 4 3 2 1
Byte 1 7 6 5 4 3 2 1 0 Gauge #1 10 Bit Control Bit #5
Byte 2 d3 d3 d2 d2 d1 d1 9 8 Gauge #2 10 Bit Control Bit #6
Byte 3 7 6 5 4 3 2 1 0 Gauge #3 10 Bit Control Bit #7
Byte 4 d6 d6 d5 d5 d4 d4 9 8 Gauge #4 16 Bit Control Bit #8
Byte 5 7 6 5 4 3 2 1 0 Control Bit #1 Control Bit #9
Byte 6 d9 d9 d8 d8 d7 d7 9 8 Control Bit #2
Byte 7 7 6 5 4 3 2 1 0 Control Bit #3
Byte 8 15 14 13 12 11 10 9 8 Control Bit #4
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 32
7.4 Character Display Message(s) [CD3] Control Message (PGN 65387)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 107 0x6B
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65387 8 7 6 5 4 3 2 1
Byte 1 7 6 5 4 3 2 1 0 Character 1
Byte 2 7 6 5 4 3 2 1 0 Character 2
Byte 3 7 6 5 4 3 2 1 0 Character 3
Byte 4 7 6 5 4 3 2 1 0 Character 4
Byte 5 7 6 5 4 3 2 1 0 Character 5
Byte 6 7 6 5 4 3 2 1 0 Character 6
Byte 7 7 6 5 4 3 2 1 0 Character 7
Byte 8 7 6 5 4 3 2 1 0 Character 8
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 33
7.5 Input Status Message [CD4] Control Message (PGN 65388)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 108 0x6C
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65388 8 7 6 5 4 3 2 1
Byte 1 d4 d4 d3 d3 d2 d2 d1 d1
Byte 2 d8 d8 d7 d7 d6 d6 d5 d5
Byte 3 d12 d12 d11 d11 d10 d10 d9 d9
Byte 4 d16 d16 d15 d15 d14 d14 d13 d13
Byte 5 d20 d20 d19 d19 d18 d18 d17 d17
Byte 6 d24 d24 d23 d23 d22 d22 d21 d21
Byte 7 d28 d28 d27 d27 d26 d26 d25 d25
Byte 8 ka ka d31 d31 d30 d30 d29 d29
Input 1 Input 9 Input 17 Input 25
Input 2 Input 10 Input 18 Input 26
Input 3 Input 11 Input 19 Input 27
Input 4 Input 12 Input 20 Input 28
Input 5 Input 13 Input 21 Input 29
Input 6 Input 14 Input 22 Input 30
Input 7 Input 15 Input 23 Input 31
Input 8 Input 16 Input 24 n/a
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 34
7.6 Output Status w/ Faults Message [CD5] Control Message (PGN 65389)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 109 0x6D
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65389 8 7 6 5 4 3 2 1
Byte 1 d4 d4 d3 d3 d2 d2 d1 d1
Byte 2 d8 d8 d7 d7 d6 d6 d5 d5
Byte 3 d12 d12 d11 d11 d10 d10 d9 d9
Byte 4 d16 d16 d15 d15 d14 d14 d13 d13
Byte 5 d20 d20 d19 d19 d18 d18 d17 d17
Byte 6 d24 d24 d23 d23 d22 d22 d21 d21
Byte 7 d28 d28 d27 d27 d26 d26 d25 d25
Byte 8 d16 d16 d15 d15 d30 d30 d29 d29
Output 1 Output 9 Output 17 Output 25
Output 2 Output 10 Output 18 Output 26
Output 3 Output 11 Output 19 Output 27
Output 4 Output 12 Output 20 Output 28
Output 5 Output 13 Output 21 Output 29
Output 6 Output 14 Output 22 Output 30
Output 7 Output 15 Output 23 Output 31
Output 8 Output 16 Output 24 Output 32
Digital Control / Status Bit Pairs
00 = OFF
01 = ON
10 = FAULT
11 = NOT USED
Unused Bytes = 0xFF
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 35
7.7 Output Status TBD Message [CD6] Control Message (PGN 65390)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 110 0x6E
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65390 8 7 6 5 4 3 2 1
Byte 1 d4 d4 d3 d3 d2 d2 d1 d1
Byte 2 d8 d8 d7 d7 d6 d6 d5 d5
Byte 3 d12 d12 d11 d11 d10 d10 d9 d9
Byte 4 d16 d16 d15 d15 d14 d14 d13 d13
Byte 5 d20 d20 d19 d19 d18 d18 d17 d17
Byte 6 d24 d24 d23 d23 d22 d22 d21 d21
Byte 7 d28 d28 d27 d27 d26 d26 d25 d25
Byte 8 d16 d16 d15 d15 d30 d30 d29 d29
Output 1 Output 9 Output 17 Output 25
Output 2 Output 10 Output 18 Output 26
Output 3 Output 11 Output 19 Output 27
Output 4 Output 12 Output 20 Output 28
Output 5 Output 13 Output 21 Output 29
Output 6 Output 14 Output 22 Output 30
Output 7 Output 15 Output 23 Output 31
Output 8 Output 16 Output 24 Output 32
Digital Control / Status Bit Pairs
00 = OFF
01 = ON
10 = NOT USED
11 = NOT USED
Unused Bytes = 0xFF
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 36
7.8 Character Display Message(s) [CD7] Control Message (PGN 65391)
PGN Dec Hex
Data Length 8 8
Data Page 0 0
PDU Format 255 0xFF
PDU Specific 111 0x6F
Transmission Repetition 200 mSec
Message Timeout 600 mSec
PGN 65391 8 7 6 5 4 3 2 1 Display Control Msg #7
Byte 1 7 6 5 4 3 2 1 0 16 Bit Hours 1
Byte 2 15 14 13 12 11 10 9 8 "." Decimal 1
Byte 3 7 6 5 4 3 2 1 0 16 Bit Hours 2
Byte 4 7 6 5 4 3 2 1 0 "." Decimal 1
Byte 5 15 14 13 12 11 10 9 8
Byte 6 7 6 5 4 3 2 1 0
Byte 7 1 1 1 1 1 1 1 1
Byte 8 1 1 1 1 1 1 1 1
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 37
Appendix A Supported ASCII Codes (1 of 3)
*Not standard ASCII Code
Code Character Description *0 0 Zero *1 1 One *2 2 Two *3 3 Three *4 4 Four *5 5 Five *6 6 Six *7 7 Seven *8 8 Eight *9 9 Nine *10 A A *11 B B *12 C C *13 D D *14 E E *15 F F
32 Space Space 33 ! Exclamation 34 " Quote 35 # Number 36 $ Dollar 37 % Percent Sign 38 & Ampersand 39 ’ Apostrophe 40 ( Open Parenthesis 41 ) Close Parenthesis 42 * Asterisk 43 + Plus 44 , Comma 45 - Minus 46 . Period 47 / Forward Slash 48 0 Zero 49 1 One 50 2 Two 51 3 Three 52 4 Four 53 5 Five 54 6 Six 55 7 Seven 56 8 Eight 57 9 Nine
33026-805J Display Spec.docx
2018, Data Panel, Corp. Printed: 3/22/2019 38
58 : Colon 59 ; Semi Colon 60 < Less Then 61 = Equal 62 > Greater Then 63 ? Question 64 @ At 65 A A 66 B B 67 C C 68 D D 69 E E 70 F F 71 G G 72 H H 73 I I 74 J J 75 K K 76 L L 77 M M 78 N N 79 O O 80 P P 81 Q Q 82 R R 83 S S 84 T T 85 U U 86 V V 87 W W 88 X X 89 Y Y 90 Z Z 91 [ Open Square Bracket 92 \ Backslash 93 ] Close Square Bracket 94 ^ Caret 95 _ Underscore 96 _ Check Box OFF 97 _ Check Box ON *255 Space Space