Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S=...

10

Transcript of Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S=...

Page 1: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.
Page 2: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.

Condição de Bragg

sendn hkl2

Page 3: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.
Page 4: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.

FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which the specimen and detector rotate. (William D. Callister, JR. Materials Science and Engineering an Introduction, John Wiley & Sons, Inc.)

Page 5: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.

FIGURE 3.20 Diffraction pattern for polycrystalline -iron. (William D. Callister, JR. Materials Science and Engineering an Introduction, John Wiley & Sons, Inc.)

Page 6: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.

Para o ferro (BCC), calcule (a) o espaçamento inter-planar, e (b) a ângulo de difração para o plano (220). O parâmetro de rede para o Fe é de 0.2866 nm. Considere uma radiação monocromática de comprimento de onda 0.1790 nm e reflexão e de primeira ordem (n=1).

Exercício

Page 7: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.

Absorção de raios-X

Page 8: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.

Microscopia eletrônica de transmissão

Page 9: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.
Page 10: Condição de Bragg FIGURE 3.19 Schematic diagram of an x-ray diffractometer; T= x-ray source, S= specimen, C= detector, and O= the axis around which.