CON-STRUCT PREFABRICATED BRIDGE SYSTEM - Tricon … Double Tub... · sheet index sht description...
Transcript of CON-STRUCT PREFABRICATED BRIDGE SYSTEM - Tricon … Double Tub... · sheet index sht description...
SHEET INDEX
SHT DESCRIPTION (281) 931-9832
TRICON PRECAST LTD.
CHECKED BY:
APPROVED BY:
of
M. VANCE
G.Nelson
G.Nelson
DRAWN BY:
1 1
TITLE SHEET
08/21/08
TRICON PRECAST LTD.HOUSTON, TEXAS
(281) 931-9832
N O T I C E:
THESE DRAWINGS ARE FURNISHED ONLY FOR THE USE OF THIS PROJECT. THE PROPRIETARY INFORMATION
SHOWN HEREIN IS NOT TO BE TRANSMITTED TO ANY OTHER ORGANIZATION
WITHOUT AUTHORIZATION FROM TRICON PRECAST, LTD.
SHEETTRICON JOB NO.: DATE:
CONTRACT NO.:
DATE MARK
REVISIONS
DESCRIPTION
D.O.T. PROJECT NO.:
LOCATION NO.:
CON-STRUCT PREFABRICATED BRIDGE SYSTEM
STANDARD PLANS
1009 44th STREET, SUITE A-2
WYOMING, MI 49509
PH. (616) 261-8630
TEG A Tricon Precast Company
TRICONENGINEERINGGROUP, LTD
1009 44th STREET, SUITE A-2
WYOMING, MI 49509
PH. (616) 261-8630
TEG A Tricon Precast Company
TRICONENGINEERINGGROUP, LTD
15055 HENRY ROAD
HOUSTON, TEXAS 77060
CON-STRUCT PREFABRICATED BRIDGE SYSTEM
STANDARD PLANS
TPL
THE DESIGN CONTAINED IN THESE DRAWINGS IS BASED ON THE TRICON PRECAST, LTD. SPECIFICATIONS
AND THE INFORMATION PROVIDED BY THE OWNER.
TM
STANDARD SPAN SERIES - 35’ THROUGH 60’
TITLE SHEET
CON-STRUCT STANDARDS (35’-60’ SPANS)
CON-STRUCT STANDARD SECTIONS (35’-60’ SPANS)
CON-STRUCT STEEL GIRDER DETIALS (35’-60’ SPANS)
1 of 1
1 of 3
2 of 3
3 of 3
30.000’ thru 60.000’ Spans
PLAN
13.0
00’
13.0
00’
24.0
00’
Road
way
1.0
00’
1.0
00’
13’-0" 13’-0"
TYPICAL TRANSVERSE SECTION
1’-0" 1’-0"
26’-0" Overall
Driving Surface
24’-0" Roadway
8’-8" Nominal 8’-8" Nominal 8’-8" Nominal
Precast Slab
C.L. Structure
7"
Min.
1"Y
"
"X"
SPAN
LENGTH
SECTION DEPTHS
"X" "Y"
FT In In
35
40
50
60
19"
19"
TM
"H"
Haunch
24"
"H"
In
2"
2"
2"
4"
CL deformed
bar anchors
Weld
PLAN
�" Min
�" Max
�(�) 8
Fill with
non-shrink
cementitious
grout
C
2 �
"
Min
to
Top
of Rod
by a Certified
Welder in accordance
with Item 448
1" Dia x 11" smooth
Lateral Connector
Rod (LCR)
SECTION
1" Dia x 11" smooth
Lateral Connector
Rod (LCR)
L Connector
Plate
Connector
Plate (Typ)
Connector
Plate (Typ)
(deformed bar anchors not shown for clarity)
GENERAL NOTES:
TABLE OF VARIABLE VALUES
8.6
67’ Individual Precast
Unit
8.6
67’ Individual Precast
Unit
26.0
00’
Overall
8.6
67’ Individual Precast
Unit
8’-8"
Galvanized Stay-in-Place
Metal Decking
2% Slope 2% Slope
9�"
9�"
14�"
Top and
Botto
m
Top and Bottom
Outside Precast
Deck Fascia
Bent Plate Top Flange (Typ)
Bent Plate Top Flange (Typ)
Deck Joint
Top of Precast Deck Span
ELEVATION
CAST-IN-PLACE CLOSURE POUR
1’ -0" Saw & Seal
(Typ)
C.I.P. Concrete
Closure Pour
#4 bar at 12" Spacing
#4 bar at 12"
Spacing
2"
Min.
Clr
Cover
�" Diameter Shear Connectors - See Sheet 3 for Spacing (Typ both flanges)
45 21" 4"
55 26" 4"
1
Center Diaphragm
(If Required)1’ -6"
Backwall
1’ -6"
Backwall
Galvanized Bent Plate Girder
Galvanized Bent Plate Girder
9�"
14�"
16�" 28�"
CHECKED BY:
APPROVED BY:
of
DRAWN BY:
CHECKED BY:
APPROVED BY:
DRAWN BY:
TRICON PRECAST, LTD.
N O T I C E:
THE DESIGN CONTAINED IN THESE DRAWINGS IS BASED ON THE TRICON PRECAST, LTD. SPECIFICATIONS
AND THE INFORMATION PROVIDED BY THE OWNER.
THESE DRAWINGS ARE FURNISHED ONLY FOR THE USE OF THIS PROJECT. THE PROPRIETARY INFORMATION
SHOWN HEREIN IS NOT TO BE TRANSMITTED TO ANY OTHER ORGANIZATION
WITHOUT AUTHORIZATION FROM TRICON PRECAST, LTD.
SHEETTRICON JOB NO.: DATE:
CONTRACT NO.:
DATE MARK
REVISIONS
DESCRIPTION
PROJECT NO.:
TRICON PRECAST LTD.
1009 44th STREET, SUITE A-2
WYOMING, MI 49509
PH. (616) 261-8630
TEG A Tricon Precast Company
TRICONENGINEERINGGROUP, LTD
15055 HENRY ROADHOUSTON, TEXAS, 77060
(281) 931-9832
SPANS 35’ THRU 60’
1TPL
08-21-08
CON-STRUCT PREFABRICATED BRIDGE SYSTEM
Fill shear keys in deck slab, full diaphragm and partial diaphragm
with packaged non-metallic, non-shrink cementitious grout that is
certified by the manufacturer to meet the requirements of ASTM
C 1107, free of chlorides, and capable of a compressive strength
of 5,000 psi after 24 hours of curing at anticipated temperatures.
Surface preparation, mixing and consistency of grout, placing, and
curing grout must follow the manufacturer’s recommendations.
Curing compounds are not allowed.
Methods of transverse load transfer include, but are not limited to:
- cast-in-place closure pour of no less than 10" in depth
- transverselypost-tensioned concreteintermediate diaphragm
- welded lateral connector
Transverse connections detals shall be provided with fabrication shop
drawings submittal.
For grouted keyway longitudinal joints, if no other method of transverse
load trasfer is provided, transverse post-tensioning shall be required. The
compressive stress due to transverse post-tensioning shall not be less than
150 psi through the deck keyway.
Prior to post-tensioing, grout between deck and diaphragm elements must
attain a minimum compressive strengh of 3000 psi.
WELDED LATERAL CONNECTOR DETAIL
Non-Shrink
Cementitious
Grout
2"
3"
1"�"
7"
Min.
(transverse post-tensioning required)
GROUTED KEYWAY
3
HAUNCH
1-6"
8’-8"
2’-2"
Precast
Slab
"Y"
EXTERIOR BEAM
"A" "A""B" "B"
Top of Precast
Deck
Bottom of Galvanized
Steel Beam
"X"
Steel Bea
m
"Y"
SPAN
LENGTH
SECTION DEPTHS
"A" "B"
FT In In
35
40
50
60
8’-8"
2’-2"
Precast
Slab
"Y"
INTERIOR BEAM
"A" "A""B" "B"
Haunch
"H"
In
Haunch
"H"
"H"
"Y"
In
2"
2"
2"
4"
GENERAL NOTES:
1’-3"
TABLE OF VARIABLE VALUES
TYPICAL SECTIONS
"H"+
7"
Deck
+
Haunch
19"
19"
24"28"
7"
Min.
2% 2%
8’-8"
BACKWALL AND FULL CENTER DIAPHRAGM CROSS SECTION
Top of Precast
Deck2%2%
7"
Min.
Lifting Anchor Recessed
Below Top of Deck (Fill
Recess with Non-Shrink
Cementitiuos Grout)
#4 bar #4 bar #4 bar #4 bar
#4 bar (TYP)
#4 bar
#4 bar
#4 bar
2"
Min.
Clr
Cover
1�
" Min.
Clr
Cover
2"
Min.
Clr
Cover
1�
" Min.
Clr
Cover
3"2"
#5 bar
"H"+
7"
Min.
55 11" 4" 26"28"
45 4" 21"
Min.
CHECKED BY:
APPROVED BY:
of
DRAWN BY:
CHECKED BY:
APPROVED BY:
DRAWN BY:
TPL
TRICON PRECAST, LTD.
08-21-08
N O T I C E:
THE DESIGN CONTAINED IN THESE DRAWINGS IS BASED ON THE TRICON PRECAST, LTD. SPECIFICATIONS
AND THE INFORMATION PROVIDED BY THE OWNER.
THESE DRAWINGS ARE FURNISHED ONLY FOR THE USE OF THIS PROJECT. THE PROPRIETARY INFORMATION
SHOWN HEREIN IS NOT TO BE TRANSMITTED TO ANY OTHER ORGANIZATION
WITHOUT AUTHORIZATION FROM TRICON PRECAST, LTD.
SHEETTRICON JOB NO.: DATE:
CONTRACT NO.:
DATE MARK
REVISIONS
DESCRIPTION
PROJECT NO.:
TRICON PRECAST LTD.
1009 44th STREET, SUITE A-2
WYOMING, MI 49509
PH. (616) 261-8630
TEG A Tricon Precast Company
TRICONENGINEERINGGROUP, LTD
15055 HENRY ROADHOUSTON, TEXAS, 77060
(281) 931-9832
SPANS 35’ THRU 60’
CON-STRUCT PREFABRICATED BRIDGE SYSTEM
TM
Galvanized Bent
Plate Girder
(Typ)
Stay-in-Place
Decking (Typ)
Stay-in-Place
Decking (Typ)
Galvanized Bent
Plate Girder
(Typ)
Anchor Bolts as Required
(See Railing Standrards)
9"(If Required)
Post-Tensioning
System (If Required)
Grout keyway between
diaphragms (If Required)
TotalWeight
Tons
19
21
25
28
32
36
25�"
25�"
25�"
35
11"
13�"
13�"
13�"
4" 28�"
Duct for Post-Tensioning
System (If Required)
32
BACKWALL SECTION
Designed according to AASHTO LRFD Specifications,
HL-93 live load.
Concrete strength ~ f’c = 6,000 psi.
All reinforcing shall be Grade 60.
Bar laps, where required, shall be as follows:
Uncoated ~ #4 = 1’-5"
~ #5 = 1’-9"
Epoxy coated ~ #4 = 2’-1"
~ #5 = 2’-7"
See railing details and standards for rail anchorage.
See bearing standards for bearing details and dimensions.
Multi-span units, with the slab continuous over
Interior Bents, may be formed with the details on this
standard.
Payment for packaged non-metallic, non-shrink
cementitious grout, for worked performed, materials
furnished and curing time, is considered subsidiary
to other bid items.
Lifting the prefabricated bridge units shall be by equal
loads to each pair of lifting devices. The lifting device
recess shall be grouted with non-shrink cementitious
grout after units are erected.
If post-tensioing is required:
Post-Tensioning System shall include post-tensioning
duct, high-strengh steel strand, anchorage, anchorage zone
reinforcement and steel bearing plates.
Post-Tensioning strand shall be 0.6" diameter, 270 ksi steel
that meets the requirements of ASTM A722.
Payment for furnishing the Post-Tensioning System is included
with the Con-Struct Prefabricated Superstructure System.
After tensioning, the post-tensioning duct shall be pressure
grouted with cementitious grout.
STUD DETAIL
�"
1�"
�"
3"
1�"
R
1
4
103^
BENT PLATE ELEVATION
BENT PLATE SECTION
CAMBER ELEVATION
BENT PLATE PLAN3"
Top
Flange
1’ -0" 1’ -0"
2"
2"
"Z"
"Z"
Ca
mber
"A"
Out ot
Out
Top
Flanges
Width
Botto
m
Flange
at
Center Span
"A"
"W"
Ca
mber
TABLE OF VARIALBLE VALUES
SPAN
LENGTH
SECTION DEPTHS
"A" "W"
FT In In
35
40
50
60
"W"
Precast Concrete
Deck Haunch
Top Flange
"X"
In
10"
"Z"
In
15"
Location Deflection
C BrgL 0.0
0.1 Span 0.31 x "Z"
0.2 Span 0.59 x "Z"
0.3 Span 0.81 x "Z"
0.4 Span 0.95 x "Z"
C SpanL "Z"
TABLE OF
DEFLECTIONS 3
DEAD LOAD DEFLECTION DIAGRAM
See Table forIntermediate Deflections
3�"
A
13.50
13.50
22.50
In 2
10"
�" Diamter Holes for
Reinforcement
(Typ Both Ends and Center)1’-3"
2"
1’-3"
2"
9"
�"X
"
9"
�"X
"
10" 9�"
9�"
14�"
"H"+
2"
"Span" - 1’
"X"
1" Diameter Weep Holes
(Typ Both Ends )1’ -9"
3"
(Typ)
FABRICATION NOTES:
�" x (H+2") Long Shear Connectors Spaced at 12"
1�"
R
(Typ.)
(Typ.)
45 10" 13.50
55 10" 18.00
28"
28"
25�"
25�"
25�"
35
14�"
16�"
9�"
CHECKED BY:
APPROVED BY:
of
DRAWN BY:
CHECKED BY:
APPROVED BY:
DRAWN BY:
TPL
TRICON PRECAST, LTD.
08-21-08
N O T I C E:
THE DESIGN CONTAINED IN THESE DRAWINGS IS BASED ON THE TRICON PRECAST, LTD. SPECIFICATIONS
AND THE INFORMATION PROVIDED BY THE OWNER.
THESE DRAWINGS ARE FURNISHED ONLY FOR THE USE OF THIS PROJECT. THE PROPRIETARY INFORMATION
SHOWN HEREIN IS NOT TO BE TRANSMITTED TO ANY OTHER ORGANIZATION
WITHOUT AUTHORIZATION FROM TRICON PRECAST, LTD.
SHEETTRICON JOB NO.: DATE:
CONTRACT NO.:
DATE MARK
REVISIONS
DESCRIPTION
PROJECT NO.:
TRICON PRECAST LTD.
1009 44th STREET, SUITE A-2
WYOMING, MI 49509
PH. (616) 261-8630
TEG A Tricon Precast Company
TRICONENGINEERINGGROUP, LTD
15055 HENRY ROADHOUSTON, TEXAS, 77060
(281) 931-9832
CON-STRUCT PREFABRICATED BRIDGE SYSTEM
3
GALVANIZED STEEL GIRDER DETAILS
3
TM
18.00
STEEL SECTION
PROPERTIES
Wt./ft
#/ft
46
46
46
62
62
77
2�"
2�"
3"
2�"
3�"
"Span" - 1’-0"
2�" Diameter
Hole for Post-
Tensioning Duct
(If Required)
Use galvanized ASTM A709, Grades 36, 50 or 50W, for all
steel. Steel shall be hot-dipped galvanized according to
ASTM A123.
Shear developers shall be �" diameter studs and meet the
tolerances specified in AWS D1.5, Section 7.4.5.
Shear delveloper spacing is based on an ADT of 10,000 vehicles
per lane with 2% Truck Traffic. Spacing will be varied based on
site specific traffic data.
All dimensions in Beam Elevation are measured horizontally.
"Z" is an approximate value, based on theoretical camber,
dead load deflection and constant grade (i.e. no vertical curve).
Beam bottom flanges and webs are classified as tension
components and are subject to impact testing requirements.
One optional shop splice is permissible for beam lengths
in excess of 50’. Do not locate the optional splice within
0.20L of either side of the centerline of span where L is
the span length between centers of bearing. Optional shop
splices must be made by full penetration groove welds.
Beams are cambered for total dead load deflection plus
long term creep effects.
Produce camber using pressure, or a combination
of heat and pressure.
Beams shall be supported at 10’ minimum intervals during
the casting of the concrete deck.