COMPRESSOR DIGITAL DEHUMIDIFIERelectriq.co.uk/wp-content/uploads/2017/11/CD10L-CD... · 5. Top...
Transcript of COMPRESSOR DIGITAL DEHUMIDIFIERelectriq.co.uk/wp-content/uploads/2017/11/CD10L-CD... · 5. Top...
COMPRESSOR DIGITAL DEHUMIDIFIER
CD10L – 10 litres per day
CD20L – 20 litres per day
USER MANUAL
Thank you for choosing ElectriQ
Please read this user manual before using this innovative Dehumidifier
and keep it safe for future reference
Visit our page www.electrIQ.co.uk for our entire range of Intelligent Electricals
1
Contents
Safety Instructions ………………..……………….. 2
Installation ………………..……………….. 4
Parts ………………..……………….. 5
Control Panel ………………..……………….. 6
Quick reference guide ………………..……………….. 7
Positioning ………………..……………….. 10
Water Drainage ……………………………….. 11
Care and Maintenance ………………..……………….. 11
Troubleshooting ………………..……………….. 13
Technical Data ………………..……………….. 14
2
SAFETY INSTRUCTIONS
Important
• Carefully read the instructions before operating the unit
• This appliance is for indoor use only and intended for use in a domestic environment only.
Any other use is not recommended by the manufacturer and may cause fire, electrical shocks
or other injury to user or property.
• Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
• Installation must be in accordance with regulations of the country where the unit is used.
• If you are in any doubt about the suitability of your electrical supply have it checked and, if
necessary, modified by a qualified electrician.
• This dehumidifier has been tested and is safe to use. However, as with any electrical
appliances - use it with care.
• Disconnect the power plug from socket before dismantling, assembling or cleaning.
• Avoid touching any moving parts of the appliance.
• Never insert fingers, pencils or any other objects though the guard
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities. It is also not intended for use by those with a lack of
experience and knowledge, unless they have been given supervision or instruction concerning
the use of the appliance by a person responsible for their safety.
• Do not leave children unsupervised with this appliance.
• Do not clean the unit by spraying it or immersing it in water.
• Never connect the unit to an electrical outlet using an extension cord. If a power outlet is
not available, one should be installed by a qualified electrician.
• Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the
power cord is not stretched or exposed to sharp object/edges.
• A damaged power supply cord should be replaced by the manufacturer or a qualified
electrician in order to avoid a hazard.
• Any service other than regular cleaning or filter replacement should be performed by an
authorized service representative. Failure to comply could result in a voided warranty.
• Do not use the appliance for any other purposes than its intended use.
• Do not tilt the unit while in use. The unit is design to work only in vertical position.
• This dehumidifier must always be stored and transported upright, otherwise irreparable
damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours
before starting the unit.
• Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off.
This prevents damage to the compressor.
• Never use the mains plug as a switch to start and turn off the dehumidifier. Use the provided
ON/OFF switch located on the control panel.
• Always place the unit on a dry and stable surface.
• The appliance should not be installed in laundry or wet rooms where the humidity is higher
than 85% RH
• Do not dry laundry above the unit to prevent water entering the dehumidifier. Place the
laundry at least 1 meter away from your dehumidifier.
• Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
3
• Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its
internals and increases the risks of operating it.
• Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in
the vicinity of this dehumidifier or any other appliance.
• This dehumidifier must not be used in spaces where there is a high concentration of gases,
solvent or other volatile organic compounds; in very dusty environments; in any domestic,
commercial or industrial environment where air composition is flammable.
Energy Saving and Unit Safety Protection Tips
• Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow
troubleshoot procedure if the self-opening louvers do not open on power on.
• For maximum performance the minimum distance from a wall or objects should be 20 cm
• Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should
only need cleaning once every three weeks (approximately).
Since the filters remove airborne particles, more frequent cleaning maybe necessary,
depending on the air quality. Vacuum both mesh and optional carbon filters and wash the
mesh filters with hot soapy water and dry them before placing them back in the unit.
Quick visual safety guide on where or when not to use your dehumidifier
4
Installation
Remove any water from the water tank before starting the unit. In order to save energy, do
not open windows or doors while the unit is running. Place the unit on a hard / flat surface.
On first use run the unit continuously for 24 hrs.
To reduce noise levels:
Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit
is running.
CD10L & CD20L dehumidifiers use compressor technology to extract water from the
environment. The compressor dehumidifiers are ideal for normal domestic or office
environment which are heated during the winter months with temperatures above
12-15⁰C. For applications where temperature is lower than 18⁰C or we recommend our
range of desiccant dehumidifiers.
CD10L & CD20L are easy to move around on castors and will extract unwanted humidity,
with setting in increments of 5% from 30-90% RH insuring your room is not dried too
much and power is not wasted.
Features
1. Easy to use controls
2. Lightweight, portable design.
3. Great for up to 3 bed (CD10L) and 5 bed (CD20L) houses
4. Cost effective way to combat mould, condensation and damp
5. Top directional dry air outlet for efficient operation and laundry mode
6. Dries laundry more efficiently than a tumble dryer
7. Designed to complement any modern space
8. Easy to carry handle
9. Castors for improved mobility (CD20L only)
10. Intelligent CPU controlled digital humidistat with 30-90% RH and room humidity display
11. Quiet fan operation ensures the right balance between low noise operation and maximum
dehumidification
12. 24 hours start / stop timer
13. Tank operation or permanent drainage option
14. Tank full alarm & auto-stop function
5
PARTS
CD10L
CD20L
1. Front Case 2. Dry Air Outlet 3. Handle
4. Control Panel 5. Air Inlet/ Filter housing 6. Back case
7. Water Tank 8. Wheels / Feet 9. Power supply cord
6
CONTROL PANEL
CD10L
LED Indicators
1. Water Full – Red
2. Compressor on – Green
3. Defrost – Green
4. Timer – Orange
Buttons
A. Power on/ off
B. Down (Humidity Settings)
C. Up (Humidity Settings)
D. Timer
7
CD20L
LED Indicators
1. Power indicator – Green
2. Timer – Orange
3. Water tank full – Red
4. Fan speed low – Green
5. Fan speed high – Green
6. Laundry mode - Green
POWER
Turn on/off the appliance
Timer
When the unit is on standby, press the timer button to set the delay until it turns on. When the
unit is on, press the timer button to set the delay until it turns off. Press the timer button to
select the delay time you require in hours cycling from 0 to 24 hrs.
Up & Down
HUMIDISTAT
Press to up/down arrows to select the desired humidity in the room. 50-55% is the
recommended setting for normal domestic settings.
The humidistat range can be selected from 30-90% RH with continuos mode option (CO)
Laundry Mode
Press this button to activate laundry mode. Laundry mode will run the dehumidifier constantly
and with the highest fan setting to quickly dry your washing.
FAN SPEED (CD20L only)
Sets fans speed to Low or High
8
Humidity Level & Timer 2 digit display
The led indicator performs the following functions: 1. When the unit is plugged in, it will indicate
the room humidity level 2. When the humidity level is selected, it will indicate the set humidity
3. When the start / stop timer is programmed will show the set timer
Notes: When humidity level is outside the normal operational parameters will show
LO/HI. If ambient humidity is lower than 35%, it will show “LO” If ambient humidity
is higher than 95%, it will show “HI”. Also the display will show the error codes.
Quick Reference Guide
Power Key Press to turn the dehumidifier on and off.
Timer: select timer settings key to adjust the timer (1-24 hrs, start/ stopping timer). In
power on mode the set number will represent the number of hours the unit will run for before
turning off. This will remain unaffected if unit goes in to defrost mode or the tank is emptied then
reinserted. In standby mode the set number represents the period in hours after which the unit
will start. To cancel start / stop mode press the timer key again until is set to 0.
Press Up or Down Settings Key when the unit is displaying the current relative
humidity to select the desired humidity level. Humidity level can be set within a range of 30% RH
(Relative Humidity) to 90% RH in 5% increments.
When the humidity is lower by 2% than the set humidity the unit will stop the compressor and
work for 3 minutes in fan only. When humidity is higher by 2% than selected humidity the
compressor will start working after a 3 minutes delay. There is humidity measurement tolerance.
Laundry Mode:
For CD20L press to automatically set the dehumidifier in laundry mode. Fan is set to
high on laundry mode
For CD10L set the humidity to CO to operate continuously with maximum water extraction until
the tank is full. Alternatively you can set the humidity level to 35%-40%RH. <40% is very dry and
the unit will work until water tank is full as 35%RH is hardly achievable in UK domestic
environment. Do not place clothes directly over any of the dehumidifier vents. Make sure that
there is nothing blocking the hot air exhaust air flow and for best results place the laundry within
1.5 meters of the dehumidifier.
Note that if permanent drainage pipe is fitted the unit will not stop operation. Humidity set to
achieve room humidity of around 35% is good for quick drying boost on initial run or emergencies,
laundry mode. Not recommended for long normal operation in domestic/ office environment.
For allowing more moisture in the air, press the humidity control key and set to a higher percent
value (e.g. 60-70%).
Humidity set to 50-55% RH; recommended setting, great for domestic operation and dry storage
Humidity set to 60% RH; great for personal comfort and applications where 50% RH is considered
too dry
Humidity set to 70% RH; ideal for unoccupied properties or where economical run is needed
without the need to go drier than 70% RH
9
Other features and Indicators
Tank Full Light
Red light will be on and the unit will beep when the tank is ready to be emptied, or when the
tank is removed or not replaced in the proper position. The water level control switch shuts off
the dehumidifier when the tank is full, or when the tank is removed or not replaced in the proper
position. Empty and replace to resume operation.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in
to defrost mode
When the unit is running in a room with temperature between 5oC and 12oC, it enters the defrost
mode about once every 30 minutes.
When the unit is running in a room with temperature between 12⁰C and 20⁰C, it enters the
defrost mode about once every 45 minutes.
Normal operation will resume after defrost mode.
Humidistat control and fan/ compressor operation
When the selected humidity is 2% lower than the user selected humidistat setting; the
dehumidifier’s compressor will be shut off automatically but the fan will still move to ensure air is
not stale in the room. The unit will use only a minimal amount of energy in fan mode.
When the humidity is equal or higher than user selected humidity the compressor will restart
once the 3 minutes delay compressor protection expires.
Power
After the unit has stopped, it is not recommended to resume operation for at least 10 minutes.
This is to protect the compressor. Operation can resume after this period lapses. When the unit is
restarted there is a 3 minutes delay before compressor will start.
Lightweight Portable Design
The dehumidifier is built to be compact and lightweight.
Your CD10L/CD20L dehumidifier is an advanced micro-CPU controlled device able of
self-diagnostics. The LED display may also show the error and protections codes.
10
Positioning the dehumidifier
A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please
ensure circulation of air in not restricted
around the unit.
Allow at least 20 cm space around the unit.
This dehumidifier is designed only for indoor
residential / small office applications and any
commercial or industrial use will invalidate the
warranty.
Use in an enclosed area for maximum
efficiency. Close all doors, windows to create an
effective operating environment. Do not use outdoors.
Your electriQ dehumidifier will begin to protect your space from the harmful effects of excessive
moisture as soon as it is turned on. Excess moisture is dispersed throughout your home. For this
reason, the dehumidifier should be positioned in a central and clear location so that it can draw this
moist air towards it from all over the home. A warm hallway or landing is an excellent position for
your dehumidifier. If possible, leave interior doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier
there and moving it to a more central location at a later date. For the most effective use, run your
dehumidifier with external doors and windows kept closed. Please note the unit should not be placed
directly against a radiator or other heat source.
When positioning your electriQ dehumidifier, ensure that it is placed clear of any obstacle that may
limit the air movement. Place the dehumidifier on a flat dry surface.
Note: Do not force castors to move over carpet or uneven surfaces, nor move the unit with water in
the tank as it may tip over and spill water.
Water Drainage
When the water tank is full, the unit will stop automatically. When this happens the tank full red
light will show on the control panel.
Note: Only empty the water tank when is full or before moving or storing the unit.
There are two ways to dispense collected water.
1. Use the tank.
When the tank is full, the unit will automatically
stop running, the unit will beep and the tank full
indicator light will flash. Slowly pull out the tank
using both hands. Grip tank securely, and carefully
pull out. Carry the tank by its handle, discard the
water and reinsert the tanks into the dehumidifier.
The tank must be in place and securely seated for
the dehumidifier to operate again. The
dehumidifier will re-start when the tank is
restored in its correct position.
11
NOTES:
When you remove the bucket, do not touch sensors or any parts which are situated
behind tank. Doing so may damage the product. Be sure to push the
tank gently all the way into the unit. Banging the bucket against
anything or failing to push it in securely into place may cause the
unit not to operate.
Do not remove any parts from the water tank or tank enclosure. The
water full sensor will no longer be able to detect the water level
correctly and water may leak from the water tank.
2. Continuous draining
Water can be automatically plumbed in or drained into a sink, a larger recipient or through
the wall into an outside drain by attaching a pipe to the unit (10 mm internal diameter) (not
included). Insert the pipe into the drain outlet at the back of the unit as shown here.
Make sure the connection between pipe and the drain outlet is tight and does not leak. Then
direct the pipe to a suitable drainage point. This unit uses gravity fall to dispose water hence
the drain should be lower than the unit water outlet. Put the tank back. Be sure to run the
water pipe downward and let the water to flow out smoothly. Do not kink or bend the pipe.
NOTE: When the continuous drain feature is not being used, remove the drain hose from
the outlet and place back the rubber bung.
The permanent drain can be used in conjunction with water pump (e.g. when draining a
cellar) to lift the water upwards.
Care and Maintenance
Always shut off the unit and unplug from the mains before cleaning or performing any
maintenance. When it is not in use for long periods it is advisable to remove the plug from
the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as
they may cause irreversible damage to the unit.
12
1. Clean the Grille and Case
Use water and a mild detergent to clean the washable antibacterial mesh filters. Do not use bleach or
abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and
can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get
soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a
soft damp cloth or kitchen towel.
Remove the ABS frame and pull out the filters from the frame. Hoover gently the optional carbon
once every 2-3 weeks approximately.
If the mesh filter is dirty hoover it, if it is heavily soiled wash it with warm soapy water and dry
thoroughly before reinserting it in the unit.
When filter cleaning is finished and filters are dry placed them back into the filter frame and
reassemble the unit.
NOTE: Never run the unit without the mesh filter frame being assembled back.
2. Clean the water tank
Every few weeks, clean the tank to prevent growth of mould, mildew and bacteria. Partially fill the
tank with clean water and add a little mild detergent. Swish it around and than empty the tank and
rinse. NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying the tank must be
reinserted securely into dehumidifier in order to restart operation.
13
End of Season Maintenance::::
1. Empty and clean the water tank.
2. Clean the unit and the filters as per cleaning procedure above.
3. Coil the power cord at the back of the unit
4. Cover the unit and keep it in a dry place.
Frequently Asked Questions
Why doesn’t the dehumidifier seem to extract much water if the temperature is low?
This is a compressor dehumidifier which works best in temperatures above 15⁰C. If the temperature is
low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want
to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our
desiccant range.
Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To rectify: empty the tank and carefully place the tank back in
the unit. Also the unit may be running in dehumidifying mode with a low room temperature. Please
check if the room temperature is lower than 5⁰C. If so, the unit will stop working while in
dehumidifying mode. (unit may be defrosting).
The ambient operating range is between 5⁰C and 35⁰C with a relative humidity ranging from 30% to
80%. For maximum efficiency use the unit between 15⁰C and 32⁰C.
Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the
humidity.
During the cold cycle there should be cold air coming out of the unit
During the hot cycle hot dry air should be coming out of the outlet grill.
14
Troubleshooting
Issue Cause Solution
Hot or cold air
being
produced
Normal Operation When the unit is in dehumidifying mode it absorbs humid air from room and
freezes it to reduce the humidity.
During the cold cycle there should be cold air coming out of the unit
During the defrost cycle hot dry air should be coming out of the outlet grill.
Unit does not
operate
Is the plug properly inserted
in the socket?
Insert the plug into the socket and turn the switch on.
Does the tank full indicator is
red?
Tank full, float displaced or tank not properly inserted. Empty tank, check float
and make sure tank is properly inserted in unit.
Front louvres
do not open
Louvre motor is blocked Check if anything is blocking the louvre
Try to move gently the louvres up and down while the unit if off
If the above fails return the unit to service centre
Dehumidifier
does not
extract water
Is the unit set to a humidity
level lower than the one in
the room?
Set the humidity level on the humidistat bellow current humidity reading.
Is the temperature too low
for water extraction to be
efficient?
Increase temperature in the room or reposition the unit.
Is any intake grill or
discharge blocked? Is the
unit too close to walls.
Remove obstructions and restart the unit.
Ensure a distance of at least 20 [cm between the unit & walls
Airflow seems
weak
Is filter dirty or clogged? Please service the filters regularly as per user manual.
Unit is noisy
during
operation
Is the unit on uneven
surface?
Please place on flat horizontal surface.
Is filter clogged? Please service the filters regularly as per user manual.
E1 Temperature sensor error Use the unit within the prescribed temperature range. Unplug the unit, rest
and plug it back in. If error repeats, call for service centre.
Defrost light
on and unit
stops regularly
Unit is defrosting Allow the unit to automatically defrost. The protection will clear after the unit
self defrosts. Increase temperature in the room if this repeats too often
Tank full red
light
Water tank full notification Tank is full or is not in the right position-- Empty the tank and replace in the
right position.
Any other malfunctions will need to be reported to ElectrIQ service centre. Do not attempt unauthorised repairs as these may
invalidate the warranty.
15
Technical data
Model CD10L CD20L
Voltage 220-240V~50Hz 220-240V~50Hz
Dehumidifying capacity 10 L / day
(at 30⁰ C / 80%RH)
20 L / day
(at 30⁰ C / 80%RH)
Fan Speeds 1 2
Power Consumption 240 W 380 W
Rated Current 1.2 Amps 2 Amps
Tank Capacity 2 litres 5 litres
Humidity settings range 30%~90% 30%~90%
Refrigerant R134a, 65 grams R134a, 250 grams
Airflow m3/h 150 150 / 200 (Low/ High)
High / Low Pressure 2.6 / 1.0 MPa 2.6 / 1.0 MPa
Max noise level dB(A) ≤42 ≤47
Power cord length 1.8 meters 1.8 meters
Dimensions mm
(WxDxH)
276x185x480 276x235x500
Weight kgs (net/ gross) 9.5 / 10.2 13.6 / 14.5
All information provided is for reference only. Products specifications may change
due to continuous product development.
Disposal: Do not dispose this product as unsorted waste. Collection of such waste must be handled
separately as special treatment is necessary.
Recycling facilities are now available for all customers at which you can deposit your old
electrical products. Customers will be able to take any old electrical equipment to participating
sites run by their local councils. Please remember that this equipment will be further handled
during the recycling process, so please be considerate when depositing your equipment. Please
contact the local council for details of your local household waste recycling centres.
16
ElectrIQ UK SUPPORT
www.ElectrIQ.co.uk/support
Please, for your own convenience, make these simple checks before calling the service line.
1. Has the unit been standing upright for at least 2 hours?
2. Is the unit plugged into the mains?
3. Is the fuse OK?
4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
5. Check if the water tank is full. Is the tank correctly inserted back into the unit?
6. Was the troubleshooting guide followed?
If the unit still fails to operate call: 0871 620 1057 or complete the online form
Office hours: 9AM - 5PM Monday to Friday
www.ElectrIQ.co.uk
Unit 2, The Nursery
Berristow Lane
South Normanton
Derbyshire, DE55 2FX