Componentes Herramientas · †Los ejemplos son para fines ... Diagrama de espaciamiento IMPORTANTE...
Transcript of Componentes Herramientas · †Los ejemplos son para fines ... Diagrama de espaciamiento IMPORTANTE...
System Components
Tools Required
AnchorRack Support ARXX-XXB-XXXX-MX
3/16” Allen Bit Power Drill Torque Wrench Spacing Sticks OR Measuring Tape Brush
KB Konnect Mid Clamp C02-XXE
Supplemental Documents Required
Fastener Table Spacing Diagram
KB Konnect End Clamp†
C00-01E-XX or CO2-XXE + C01-XXE
Module thk, t = 40mm
or
Modules thk, t ≠ 40mm
⚠ IMPORTANT Only qualified professionals should install solar panels, DC cabling, and any anti-lightning safety devices. While installing the PV system, proper safety equipment should be worn.
Concrete Sealant†
Concrete Fasteners†
†Examples shown. Selection is project-dependent
For Reference Only – Images and diagrams used in this manual are for reference only. Your project will have specific documents and dimensions.
ANCLADO AL TEHO DE LOZA (PARA SISTEMAS CON PERFORA-
Componentes
ARXX-XXB-XXXXMXSoporte AnchorRack
C02-XXEGrapa interior KB Konnect
C00-0-E-XXo CO2-XXE + C01-XXE
Grapa exterior KB Konnect
Sellador para Concreto†
Sujetadores para concreto†
†Los ejemplos son para fines ilustrativos, la selección real depende de cada proyecto.
Módulo thk, t=40 mm Módulos thk, t ≠40 mm
ó
HerramientasLlave Allen de 3/16” Taladro Llave de Torsión (dinamométrica)Varas de Espaciamiento ó Cinta Métrica
Documentos ComplementariosTabla de SujetadoresDiagrama de espaciamiento
IMPORTANTE
Solo profesionales calificados deben instalar paneles solares, cableado, pararrayos y dispositivos asociados.
Utilizar equipo de protección personal adecuado mientras instale el sistema FV.
Brocha
Las imágenes y diagramas utilizados en este manual son solo con fines ilustrativos. Su proyecto tendrá documentos y dimensiones específicos.
Version 1, Oct 2018
KB Racking - México
www.kbracking.com/es • [email protected] • 55.41.17.85.51 Varsovia 36, Col. Juárez, Interior 731,CDMX, 006600, México
Pre-installation Steps AnchorRack Supports must be cut in half for North-most and South-most array rows. See below image for guidance. The Bottom-Half of the Support (#1) will be used for the South-most row of the array. The Top-Half (#2) is used for the North-most row of the array.
Step 1 – Align AnchorRack Supports Place your first AnchorRack Support at the corner of an array. The distance between Supports is project specific, refer to your Spacing Diagram to obtain distances for the N/S and E/W directions. Note: Half-Supports must only be installed on North-most and South-most Rows (see pre-installation step for clarity).
Step 2 – Apply Sealant A caulk gun is recommended for sealant application. Apply a ¼” bead on the bottom face of the Support, 2” from every edge, as shown in the figure. When the support is set in place, a small bleed-out of sealant should be present around the support perimeter.
Step 3 – Install Concrete Fasteners Secure each AnchorRack Support to the roof using concrete fasteners. Use the Fastener Table to determine the number of fasteners required per Support. Follow the fastener manufacturer’s installation instructions to correctly secure the AnchorRack Support to the roof. Apply Sealant on the fastener heads. Use a brush to even out sealant on screws.
Step 4 – Install Modules Begin module installation at array corners. Place module on four AnchorRack Supports. Secure modules to Supports by clicking KB Konnect clamps into the Supports. Completely install clamps by torqueing down. Refer to pre-installation step for clamp locations. Torque to 8.3Nm (6.1 ft-lb). There should be no gaps between KB Konnect clamps and the module frame. Complete installing modules for each row of panels.
Grounding and Bonding Install ETL certified grounding lugs on AnchorRack Supports. Only one grounding lug is required per array. Grounding hardware not provided.
Pasos de PreinstalaciónPara las filas de extremo norte y extremo sur se deben cortar los soportes AnchorRack corresponidentes, como se muestra en la imagen siguiente. La mitad mas corta (#1) se utilizará para la fila de extremo sur del arreglo, mientras que la mitad mas alta (#2) se utiliza para la fila de extremo norte.
Paso 2. Aplicar el SelladorSe recomienda una pistola de calafateo para la aplicación.
Aplique una linea de 1/4” sobre a 2” de cada borde de la cara inferior del soporte, como se muestra en la figura.
Cuando el soporte se coloca en su lugar, un poco de eceso debe de sobresalir alrededor del perimetro del soporte;
Paso 3. Instale los sujetadores para concretoAsegure cada soporte Anchorack a su techo de loza utilizan-do los sujetadores para concreto siguiendo las instrucciones de instalacion de los sujetadores de acuerdo al fabricante. Utilice la Tabla de Sujetadores para determinar el numero de sujetadores por soporte.
Aplique sellador los cabezalesde los sujetadores. Use una brocha para remover el exceso.
Paso 1. Alinear los soportes AnchorRackColoque su primer soporte AnchorRack en una esquina del arreglo. Las distancias Norte-Sur y Este-Oeste entre cada soporte es especifico para cada proyecto, de acuerdo con su con su diagrama de espaciamiento.
Nota: Los soportes cortados solo se instalan en las filas de extremo norte y extremo sur (Ver el paso de preinstalación para mayor claridad.)
Paso 4. Instalar los MódulosInicie la instalación de los paneles en las esquinas del arreglo. Coloque el módulo sobre cuatro soportes AnchorRack. Asegure los paneles al soporte insertando las grapas de sujeción en los soportes hasta escuchar ‘click’. Finalice el aseguramiento del panel apretando hasta el torque necesario. Refiérase al paso de prein-stalación para la posición de las grapas.
Apriete hasta un torque de 8.3 Nm (6.1lb-ft). No debe quedar espaciamiento alguno entre la grapa y el marco del panel.
Continue la instalación de los paneles completando fila por fila.
Instale las terminales de conexión a tierra certificadas en ETL en los soportes AnchorRack. Solamente se requiere una terminal de conexión a tierra por arreglo. El resto de los materiales para conectar a tierra no son proovistos por KBRacking.
Mitad mas corta del Soporte (#1)Fila de exremo Sur
Mitad mas alta del Soporte (#2)Fila de exremo Norte
Espaciem
iento N
orte-Su
r
Espaciemiento Este-Oeste
Grapa exterior con bloque t≠40 mm
Grapa exterior t=40 mm
Grapa interior
Sellador
Cara Inferior