Competence from tradition since 1856 - POHL Fassaden · Competence from tradition since 1856....
Transcript of Competence from tradition since 1856 - POHL Fassaden · Competence from tradition since 1856....
Cover: Eiffel Tower, Paris, France Architect: Agence Moatti-RivièreFacade system: POHL Europanel®
Material: Aluminum
Project: One World Trade Center, New York City, USA Architect: Skidmore, Owings & Merrill LLPFacade system: POHL Europanel®
Material: Stainless steel
02 | POHL EUROPANEL®
POHL EUROPANEL®
THE ELEGANT ONE
When vertically structured surfaces need to convey a serene, organic impression, POHL Europanel® is the panel of choice. Regardless of the material or surface selected, the rounded edges of the wall panels create a clean joint pattern with soft shading.
And POHL Europanel® also offers impressive functionality with many clever details. The highly versatile substructure profi les can be installed in many different ways. They ensure drainage while reliably channeling rainwater at the same time – with no wear-prone seals whatsoever. In addition to making installation fast and easy, special suspension clips also decouple the panels from the subst-ructure, so movement due to thermal expansion and con-traction remains silent. The installation frame system itself can be arranged either in a concealed or visible confi gura-tion. Designers can use this to technically accentuate an area’s visual impact.
POHL Europanel® not only serves as an attractive facade, but also exhibits its decorative and functional effect in inte-rior spaces – in the form of an acoustic wall, for example.
POHL EUROPANEL® | 03
POHL Europanel®
TYPICAL JOINT DETAIL - 3D CAD FILE
--
E U R O P A N E L S Y S T E M
D-01 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
A
L
N
P
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
K
M
B
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
M
L
B
A
P
Drawing Nr.
D-01(3D)
TYPICAL DETAIL | Cross Joint - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
N
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
04 | POHL EUROPANEL®
POHL Europanel®
TYPICAL DETAIL @ SILL - 3D CAD FILE
--
E U R O P A N E L S Y S T E M
D-02 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
A
LN
P
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
DK
M
C
B
Q
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
D
M B
A
Q
L
P
Drawing Nr.
D-02(3D)
TYPICAL DETAIL | Sill - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
N
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
POHL EUROPANEL® | 05
POHL Europanel®
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
--
E U R O P A N E L S Y S T E M
D-03 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
A
LN
P
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
K
C
B
R
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
N
B
TYPICAL DETAIL | Glazing Head - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
A
Date: OKT-2015
Drawing Nr.
D-03(3D)
P L
R
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
06 | POHL EUROPANEL®
POHL Europanel®
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
DETAIL @ GLAZING SILL - 3D CAD FILE
--
E U R O P A N E L S Y S T E M
D-04 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
L
N
P
D
F
K
M
C
R
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
Drawing Nr.
D-04(3D)
TYPICAL DETAIL | Glazing Sill - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
F
L
P
NA
R
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
POHL EUROPANEL® | 07
POHL Europanel®
Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® SystemTYPICAL DETAIL | Glazing Head - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
Date: OKT-2015
Drawing Nr.
D-05(3D)
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-05 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
LN
P
DK
C
B
B
R
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
D
B
N
B
P L
R
A
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
08 | POHL EUROPANEL®
POHL Europanel®
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
Drawing Nr.
D-06(3D)
TYPICAL DETAIL | Glazing Sill - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
DETAIL @ GLAZING SILL - 3D CAD FILE
--
E U R O P A N E L S Y S T E M
D-06 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
L
N
P
D
F
H
K
M
C
R
A
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
NF
H
L
P
N A
R
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
POHL EUROPANEL® | 09
POHL Europanel®
Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® SystemTYPICAL DETAIL | Glazing Jamb - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
Date: OKT-2015
Drawing Nr.
D-07(3D)
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-07 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
N
P
B
R
L
D F
H
K
M
C
B
J
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
N
B
P
L
A
R
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
10 | POHL EUROPANEL®
POHL Europanel®
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
Drawing Nr.
D-08(3D)
TYPICAL DETAIL | Glazing Jamb - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-08 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
N
P
B
R
L
D K
M
C
B
J
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
N
B
L
A
RP
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
POHL EUROPANEL® | 11
POHL Europanel®
Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® SystemTYPICAL DETAIL | Outside Corner - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
Date: OKT-2015
Drawing Nr.
D-09(3D)
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-09 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
NP
B
L
K
C
B
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
K
B
N
B
P
L
A
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
12 | POHL EUROPANEL®
POHL Europanel®
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
Drawing Nr.
D-10(3D)
TYPICAL DETAIL | Inside Corner - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-10 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
N
P
B
L
D
F
H
K
C
B
F
L
B
A
N
P
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
POHL EUROPANEL® | 13
POHL Europanel®
Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® SystemTYPICAL DETAIL | Parapet - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
Date: OKT-2015
Drawing Nr.
D-11(3D)
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-11 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
N
L
D
F
K
M
C
B
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
A
P
C
N
B
P
AL
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
14 | POHL EUROPANEL®
POHL Europanel®
Date: OKT-2015Headquarter | Robert-Bosch-Str. 6 | 50769 Cologne | Germany Phone: +49 221 70911-0
POHL Europanel® System
Drawing Nr.
D-12(3D)
TYPICAL DETAIL | Parapet - 3D CAD FILE
Copyright Christian Pohl GmbH. This drawings and the ideas incorporated therewith are our property. Use and copy only with our permission.
Windows and door details are shown only for reference and not usable as construction details.
ISOMETRIC VIEWEuropanel® Support System
ISOMETRIC VIEWEuropanel® Cladding System
--
E U R O P A N E L S Y S T E M
D-12 (3D) -
-1 ISOMETRIC VIEW @ EUROPANEL SUPPORT SYSTEM
-2 ISOMETRIC VIEW @ EUROPANEL CLADDING SYSTEM
A
N
L
D
K
M
C
B
LEGEND :
A
B
C
D
E
F
G
H
J
K
L
M
P
Q
R
S
T
N
A
P
S
B
S
N
P
LA
REFA B C D E F G H J K L MNPQRST
LegendPOHL Rainscreen PanelPOHL Rainscreen TrackPOHL Rainscreen Bracket Sized to Suit ProjectSubgirt Channel Sized to Suit ProjectPOHL Return PinPOHL Clip (Isolator)ø 4.8 mm x 13 mm PH Screw (Typical)M6 x 16 mm Bolt w/ Nut (Typical)ø 6.3 mm x 25 mm HWH Drill-fl ex Screw – Typicalø 6.3 mm x 25 mm HWH Drill-fl ex Screw (Sealed) – TypicalInsulation Per Project RequirementsAir & Water MembraneExternal SheetingMetal Stud Framing Minium 16 gaugeConcreteGlazing System by OthersPOHL Aluminum Buttstrap Profi leAluminum Angle Trim
POHL EUROPANEL® | 15
POHL Europanel®
FACADE CLADDINGPRELIMINARY REMARKS
In our tenders we offer for production, delivery and/or as-sembly of the POHL facade cladding panel systems with the required carrier tracks.
We are credited to EN 1090-1, 1090-2 and 1090-3. Our products are supplied with the required CE marks. If a specific execution class for welded structures is required by the client, this information is to be provided to us in the request for tender.
The request for pricing should include all necessary drawi-ngs and details so that we can determine the scope of work and provide our according pricing and tender.
Revisions of drawings and details will require the pricing to be revised accordingly.
The customer is required to check the offer to be in line with his request for pricing.
The facade design complies with building material class A1 (non-combustable).
SHEET-METAL CASSETTE FACADE
SYSTEM DESCRIPTION
Back-ventilated rainscreen facade system made from ben-ded metal sheets with hook & pin fixings.
The standard panels are bended with a Z-shape return at the top, U-shape return at the bottom and L-shape returns at the sides. The corners are typically not welded.
The panels have a pre-installed hook in pin (POHL Return Pin) which will engage into the vertical drainage and carrier channel tracks on site.
The track system is typically made from aluminum to ensure the long term durability of the cladding system.
The POHL Macrolon clips in the hook-in slots enable a tight engagement of the panels to the carrier tracks but still allow for full thermal expansions and avoid any unwanted noises.
All fixings and screws must be made of stainless steel. The screws and fixings are typically not part of the POHL cladding package and is provided by the installer.
CONSTRUCTION MATERIAL:
POHL Europanel® Headquarter Christian Pohl GmbH
Robert-Bosch-Str. 6 50769 Cologne Germany
16 | POHL EUROPANEL®
Project: Cathedral of Christ the Light, Oakland, USAArchitect: Kendall Heaton AssociatesFacade system: POHL Europanel®
Material: Aluminum
POHL EUROPANEL® | 17
ARCHITECTURAL HIGHLIGHTS –
WORLDWIDE
Tra
nspo
rtatio
n Hub, N
ew York
Skylabs, Heidelberg
Whi
te C
olla
r Fac
tory
, Lon
don
ARCHITECTURAL HIGHLIGHTS –
WORLDWIDE
26 | POHL EUROPANEL®
Amazon Block 19, Seattle
Thomas M
ore Square, London
Santa Monica Parking Garage, Santa Monica
DFB Museum, Dortmund
Winspear Opera House, Dallas
Spaceport America, New M
exico
Gesundheitshaus, Essen
School of Art and Art History, Iowa City
Flurpark, Zurich
POHL EUROPANEL® | 27
Pohl Inc. of America
6161 West Double Eagle CircleWest Valley City, UT 84118USA
Phone: +1 801 988-1305Fax: +1 801 988-1310
HeadquarterChristian Pohl GmbH
Robert-Bosch-Str. 650769 CologneGermany
Phone: +49 221 70911-0Fax: +49 221 70891-23
-Group of Companies
Copyright © 12/2016 Christian Pohl GmbH. ® Registered trademark. Contents subject to correction or change based on technical developments. All rights reserved. Revised/printed 12/2016.