Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally...
Transcript of Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally...
![Page 1: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/1.jpg)
![Page 2: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/2.jpg)
Company Profile
Tianjin Geneuo Technology Co., Ltd. specializes in the development, production and sales of industrial
automation products, system integration and engineering service.
Communication solution
-Industry EtherNET Switch
-Fieldbus modules: ProfiNET, EtherNET/IP, EtherCAT, MODBUS TCP/IP I/O modules
Inductive sensors
-Different housing design are available:M5 to M80 and cubic
Optimized connection technology for efficient automation
-M5 to M40 receptacle, pre-moulding cable, field wireable connectivity
-Passive junction box and splitters
-Industrial network connectors for ProfiNET, EtherNET/IP, EtherCAT, MODBUS TCP/IP,Profibus,DeviceN-
ET,CC-link.
LED lighting
- Machine station lighting
- Factory lighting
- Intelligent lighting solutions
Geneuo exceptionally large product portfolio does not only cover all relevant standard solutions but also the
special requirements of individual industries. The products and the total solution have been widely used in
automotive, iron & steel, machine tool, elevator, textile, packaging, rubber machine etc.
![Page 3: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/3.jpg)
ContentsDigital I/O field bus modules
10
14
16
GX_DI8 Compact modules
GX_DO8 Compact modules
17
18
GX_DO16 Compact modules
GX_DI8DO8 Compact modules
Accessories
36Connectors(Power Supply)
Index
Index
42
Analog combined field bus modules
19GX_DI8AI4 combined modules
22GX_DI8AI4-0030 combined modules
21GX_DI8AI4-0020 combined modules
GX_DI16 Compact modules
20GX_DI8AI4-0010 combined modules
23GX_DI8AI4-0090 combined modules
26Connectors(Ethernet)
37
39
Connectors(I/O)
Field wirable connectors
33Connectors(PROFIBUS-DP)
12
GX_DIO16 Configurable compact modules
24GX_DIO8AO4-0009 combined modules
34Connectors(DeviceNet)
![Page 4: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/4.jpg)
GX series compact modules system
02 GSEE TECH
Features
- Protection degree upto IP67- ensuresmost successful application on-site
Fully sealed design- gives excellentvibration resistance feature
Smart and compact housing- makes installation much more easier
-
-
Communication
- Support for multiple open bus protocol
IP67 connector design, safety and reliablility
High integration communicationkernel, high-speed & stability
-
-
![Page 5: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/5.jpg)
03 GSEE TECH
Signal
- Support various kinds of signals, such as: digital & analog signals
Various signal combination function, suitablefor complex signal transmission requirements
Configurable modules for Input/Output and 4...20 mA/0...10 V signals make application much more handily
-
-
Connection
- Perfect connectors product line ensuresvarious connection for modules
Pre-moulding - T type - Field wirable connectors
Various kinds of connectors, fully satify your different requirements
-
-
DI
DO
DIO
AI-I/U
AO-I/U
![Page 6: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/6.jpg)
GX series compact modules system
04 GSEE TECH
The power interface
- Each module include male and female 7/8’’ connectors (1 male 1 female)Each power supply interface including the system power supply and load power supplyPre-moulding/Field wireable connectors
-
-
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
B
D
A
C Station Fieldbus addressing
- No address switch with PROFINET
The I/O interface- Each module has 8 female M12 A-code I/O interface Each M12 interface provide power supply and signal channel Pre-moulding/Field wireable connectors
--
The Fieldbus interface- Ethernet modules, each module has two male D-code M12
connectors interface PROFIBUS-DP, each module has two B-code M12 connectors interface(1 male 1 female)Devicenet,each module has two A-code M12 connectors interface(1 male 1 female)Pre-moulding/Field wireable connectors
-
-
-
7
1
5
AI
4
8
3
DI
2
PI
1
GX 0010
Product series
4 Number of channels4:8:16:
4 channels8 channels16 channels
Communication protocolDP: DN: PI: EN: EI: EC:
2
Signal typesDI:DO:DIO:
3 Special codes0 0 0 0
(DI):0-PNP、1-NPN
(DO):0-0.5A、1-2A
(AI):0-I、1-U、2-PT、3-TC、9-U/I
(AO):0-I、1-U、9-U/I
7
GX series modules type codes
6
4
PROFIBUS-DP DeviceNET PROFINET MODBUS-TCP/IP EtherNET/IP EtherCAT
Digital inputDigital outputDI/DO configured
Signal typesDO:AI:AO:
5Digital outputAnalog inputAnalog output
6 Number of channels
GX series module accessories selection guide
* Other agreement dial the code can be found in the P6 - P8
4:8:16:
4 channels8 channels16 channels
11
4
4
3
3
2
2
![Page 7: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/7.jpg)
05 GSEE TECH
A:Power interface7/8” single-ended pre-cast plug-in(female)
(Used to connected to the module and power supply )
MK5-*M
7/8” double-end pre-cast plug-in
(Used for power supply connection between modules and modules)
MK5 MZ5-*M
-
B:I/O interfaceSingle signal module(DI8、DO8)
M12 3 pin A-code single-ended pre-cast plug-in(1 male)
(Used to connected to the terminal or the scene can be wiring connector)
EZ3-*M/P00
M12 3 pin A code double-end pre-cast plug-in
(Used for the I/O connected to the plug-in type sensor or actuator )
EK3 EZ3-*M/P00
Dual signal module(DI16、DO16、DIO16、DI8DO8)
M12 4 pin A-code single-ended pre-cast plug-in(1 male)
(Used to connected to the terminal or the scene can be wiring connector)
EZ4-*M/P00
M12 4 pin A code double-end pre-cast plug-in
(With the T type for I/O with plug-in sensor or actuator connection)
EK4 EZ4-*M/P00
-
-
D:Fieldbus interface
-
EthernetRJ45/M12 D- code male connectors(Module-Switch/PLC)SRJ45S EIZ4-*M/F**
M12 Pre-moulding D- code connectors(male)(Modules-modules)EIZ4 EIZ4-*M/F**PROFIBUS-DPM12 Pre-moulding Female B-code (Module-PLC/IP20 Slaves)EPK5-*MM12 Pre-moulding B-code(Modules-modules)EPK5 EPZ5-*MDeviceNetM12 Pre-moulding Female A-code(Module-PLC/IP20 Slaves)ENK5-*MM12 Pre-moulding B-code(Modules-modules)ENK5 ENZ5-*M
-
-
-
* Details, refer to P36,Field wirable connector, refer to P39
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
MK5-*M MK5 MZ5-*M
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
* Details, refer to P37,Field wirable connector, refer to P40
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
Single signal module
Dual signal module
-
-
-
EZ3-*M/P00
EK3 EZ3-*M/P00
EZ4-*M/P00
EK4 EZ4-*M/P00
EK3 EZ3-*M/P00
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
PWR
I0
I1
I2
I3 I 7
I 6
I 5
I 4
1
2
3
4 8
7
6
5
BUS
SRJ45S EIZ4-*M/F** EIZ4 EIZ4-*M/F**
EPK5-*M EPK5 EPZ5-*M
ENK5-*M ENK5 ENZ5-*M
-
-
* Details, refer to P26-P35
![Page 8: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/8.jpg)
06 GSEE TECH
Ethernet
Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.
1 2
534
Port2
1
2
5
3
4
EtherNet-IP PORT1/2
012345678
9 012345678
9
x10 x1
012345678
9
IP Address
0 - DHCP / BOOTP
1 ... 254 - IP Address Byte 4
255 - DHCP / BOOTP
x100
Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.
1 2
534
Port2
1
2
5
3
4
PROFINET PORT1/2 GreenRedGreenRedGreenFlashing greenFlashing RedOffQuickly flashinggreenSlowly flashing greenOff
PWR
MS
NS
LINK
LED-Based DiagnosisOKUL failureOKModule failureOKPLC in STOP stateIP address not setNo connection with PLCEthermet link established,communication presentEthermet link established,no communication presentNo link
GreenRedOffGreenGreen, flashingRedRed, flashingOffGreenGreen, flashingRedRed, flashingOffGreenGreen, flickeringYellowYellow, flickering
PWR
MS
NS
LINK
LED-Based DiagnosisOKUL failureNo power or no IP addressOnline, one or more connections established (CIP Class 1 or 3)Online, no connections establishedDuplicate IP address, FATAL errorOne or more connections timed out (CIP Class 1 or 3)No powerControlled by a Scanner in Run stateNot configured, or Scanner in Idle stateMajor fault (EXCEPTION-state, FATAL error etc.)Recoverable fault(s). Module is configured, but stored parameters differ from currently used parameters.No link, no activityLink (100 Mbit/s) establishedActivity (100 Mbit/s)Link (10 Mbit/s) establishedActivity (10 Mbit/s)
PWR
MS
LK1 LK2
NS
I0
I1
I2
I3
I4
I5
I6
I7
I14
I15
I12
I13
I10
I11
I 8
I 9
PWR
MS
LK1 LK2
NS
I0
I1
I2
I3
I4
I5
I6
I7
I14
I15
I12
I13
I10
I11
I 8
I 9
![Page 9: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/9.jpg)
07 GSEE TECH
Ethernet
Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.
1 2
534
Port2
1
2
5
3
4
EtherCAT PORT1/2
Address : 0...999
012345678
9 012345678
9
x10 x1
012345678
9
x100
Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.
1 2
534
Port2
1
2
5
3
4
Modbus PORT1/2
012345678
9 012345678
9
x10 x1
012345678
9
IP Address
x100
PWR
MS
NS
LINK
LED-Based Diagnosis
GreenRedOffGreenGreen, flashingRedRed, flashingOffGreenRedRed, flashingAlternating Red/greenOffGreenGreen, flickeringYellowYellow, flickering
PWR
MS
NS
LINK
LED-Based DiagnosisOKUL failureNo IP address or Exception stateAt least one Modbus message receivedWaiting for first Modbus messageIP address conflict detected, FATAL ERRORConnection timeout. No powerNormal operationMajor fault, FATAL ERRORMinor faultFirmware update from file system in progressNo link, no activityLink (100 Mbit/s) establishedActivity (100 Mbit/s)Link (10 Mbit/s) establishedActivity (10 Mbit/s)
GreenRedOffGreenGreen, blinkingGreen, single flashFlickeringRedOffRed, blinkingRed, single flashRed, double flashRedOffFlickeringFlashing greenGreen
OKUL failureINIT (or no power)OPERATIONALPRE-OPERATIONALSAFE-OPERATIONALBOOT(Fatal Event)No errorInvalid configurationUnsolicited state changeApplication watchdog timeoutApplication controller failureNo linkBooting error detectedLink sensed, traffic detectedLink sensed, no traffic detected
MODBUS TCP/IP
MS
LK1 LK2
NS
I0
I1
I2
I3
I4
I5
I6
I7
I14
I15
I12
I13
I10
I11
I 8
I 9
PWR
MS
LK1 LK2
NS
I0
I1
I2
I3
I4
I5
I6
I7
I14
I15
I12
I13
I10
I11
I 8
I 9
![Page 10: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/10.jpg)
08 GSEE TECH
PROFIBUS-DP/DeviceNet
1.Drain2.+V3.-V4.CAN_HIGH5.CAN_LOW
1
2
5
3
41
2
5
3
4
DeviceNet
0 ... 63
012345678
9 012345678
9
x10 x1
012345678
9
DR NA NA Address NA
0 ... 2Baud rateDR
DR
Kbit/s
DR 0 1 2
250125 500Address
1-No used2-Bus-A3-No used4-Bus-B5-Shield
15
42
3
1
5
4 2
3
Bus in(male) Bus out(female)
PROFIBUS-DP
0 ... 99012345678
9 012345678
9
x 10 x 1
ADDRESSAddress
GreenOffOffRedGreenRed
PWR
ERR
BUS
LED-Based DiagnosisOKUS failureOKUL failureOKPLC in STOP state
GreenRedOffGreenGreen, flashingRedRed, flashingAlternating Red/GreenOffGreenGreen, flashing
RedRed, flashingAlternating Red/Green
PWR
MS
NS
LED-Based DiagnosisOKUL failureNot online / No network powerOn-line, one or more connections are establishedOnline, no connections establishedCritical link failure, fatal evenOne or more connections timed-outExecuting self testNot operatingOperating in normal conditionMissing, incorrect or incomplete configuration, device needs commissioning.Unrecoverable Fault(s)Recoverable Fault(s)Executing self tes
PWR
MSNS
I0
I1
I2
I3
I4
I5
I6
I7
I14
I15
I12
I13
I10
I11
I 8
I 9
PWR
ERRBUS
I0
I1
I2
I3
I4
I5
I6
I7
I14
I15
I12
I13
I10
I11
I 8
I 9
Bus in(male) Bus out(female)
![Page 11: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/11.jpg)
09GSEE TECH
![Page 12: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/12.jpg)
10 GSEE TECH
GX_DI8 compact modules
Ordering data
GXDP-DI8 GXDN-DI8
GXPI-DI8 GXEC-DI8 GXEI-DI8 GXEN-DI8
Technical specifications
7/8”; 5-pole; U B max. 9 A, U L max. 9 A24 V DC (18…30.2 V), acc. to EN61131-2< 120 mA
M12, A-coded8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Input M12 x 1
Byte
0
bit0
C1P4
bit1
C2P4
bit2
C3P4
bit4
C5P4
bit3
C4P4
bit5
C6P4
bit7
C8P4
bit6
C7P4
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
8 channel Digital input(PNP)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
One channel per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
Digital input
MODBUS TCP/IP
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
PW
R
I0 I1 I2 I3I7I6I5I4
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
EE
* DeviceNet module Power supply 7/8” 4pins
![Page 13: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/13.jpg)
11 GSEE TECH
GX_DI8-1000 compact modules
Ordering data
GXDP-DI8-1000
GXPI-DI8-1000 GXEC-DI8-1000 GXEI-DI8-1000 GXEN-DI8-1000
Technical specifications
7/8”; 5-pole; UB max. 9 A, UL max. 9 A24 V DC (18…30.2 V), acc. to EN61131-2< 120 mA
M12, A-coded8(for 3-wire sensors or mech. switches,npn)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Input M12 x 1
Byte
0
bit0
C1P4
bit1
C2P4
bit2
C3P4
bit4
C5P4
bit3
C4P4
bit5
C6P4
bit7
C8P4
bit6
C7P4
Digital input
MODBUS TCP/IP
PW
R
I0 I 1 I2 I3I7I6I5I4
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
8 channel Digital input(NPN)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
One channel per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
![Page 14: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/14.jpg)
12 GSEE TECH
GX_DI16 compact modules
Ordering data
GXDP-DI16 GXDN-DI16
PW
R
I0 I8 I1 I9 I2 I 10
I3 I11
I7 I15I6 I14I5 I13I4 I12226
62
6.3
24
39.7
213
GXPI-DI16 GXEC-DI16 GXEI-DI16 GXEN-DI16
Technical specifications
7/8"; 5-pole; U B max. 9 A, UL max. 9 A24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded16(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Input M12 x 1
Byte
0
1
bit0
C1P4
C1P2
bit1
C2P4
C2P2
bit2
C3P4
C3P2
bit4
C5P4
C5P2
bit3
C4P4
C4P2
bit5
C6P4
C6P2
bit7
C8P4
C8P2
bit6
C7P4
C7P2
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Digital input
MODBUS TCP/IP
1 2 3 48765
BU
S
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
16 channel Digital input(PNP)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
Two channels per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
EE
* DeviceNet module Power supply 7/8” 4pins
![Page 15: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/15.jpg)
13 GSEE TECH
GX_DI16-1000 compact modules
Ordering data
GXDP-DI16-1000
GXPI-DI16-1000 GXEC-DI16-1000 GXEI-DI16-1000 GXEN-DI16-1000
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded16(for 3-wire sensors or mech. switches,npn)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Input M12 x 1
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
MODBUS TCP/IP
PW
R
I0 I8 I1 I9 I2 I 10
I3 I11
I7 I15I6 I14I5 I13I4 I12
226
62
6.3
24
39.7
2131 2 3 4
8765
BU
S
Byte
0
1
bit0
C1P4
C1P2
bit1
C2P4
C2P2
bit2
C3P4
C3P2
bit4
C5P4
C5P2
bit3
C4P4
C4P2
bit5
C6P4
C6P2
bit7
C8P4
C8P2
bit6
C7P4
C7P2
Digital input
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
16 channel Digital input(NPN)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
Two channels per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 16: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/16.jpg)
14 GSEE TECH
GX_DO8 compact modules
Ordering data
GXDP-DO8 GXDN-DO8
GXPI-DO8 GXEC-DO8 GXEI-DO8 GXEN-DO8
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded8(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Output M12 x 1
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Byte
0
bit0
C1P4
bit1
C2P4
bit2
C3P4
bit4
C5P4
bit3
C4P4
bit5
C6P4
bit7
C8P4
bit6
C7P4
Digital output
MODBUS TCP/IP
PW
R
O0
O7
O6
O5
226
62
6.3
24
39.7
2131 2 3 4
8765
BU
S
O1
O2
O3
O4
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
8 channel Digital output(0.5A)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
One channel per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
EE
* DeviceNet module Power supply 7/8” 4pins
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 17: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/17.jpg)
15 GSEE TECH
GX_DO8-0100 compact modules
Ordering data
GXDP-DO8-0100
GXPI-DO8-0100 GXEC-DO8-0100 GXEI-DO8-0100 GXEN-DO8-0100
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded8(DC actuators)18…30 VDC 2 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz2A/Ch.(Amax=4*2A)galvanic isolation against the bus
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Output M12 x 1
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
MODBUS TCP/IP
PW
R
O0
O7
O6
O5
226
62
6.3
24
39.7
2131 2 3 4
8765
BU
S
O1
O2
O3
O4
Byte
0
bit0
C1P4
bit1
C2P4
bit2
C3P4
bit4
C5P4
bit3
C4P4
bit5
C6P4
bit7
C8P4
bit6
C7P4
Digital output
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
8 channel Digital output(2A)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
One channel per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 18: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/18.jpg)
16 GSEE TECH
GX_DO16 compact modules
Ordering data
GXDP-DO16 GXDN-DO16
GXPI-DO16 GXEC-DO16 GXEI-DO16 GXEN-DO16
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded16(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Output M12 x 1
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Digital output
MODBUS TCP/IP
PW
R
O0 O8
O1 O9
O2
O 10
O3
O11
O7 O15
O6 O14
O5 O13
O4 O12
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
Byte
0
1
bit0
C1P4
C1P2
bit1
C2P4
C2P2
bit2
C3P4
C3P2
bit4
C5P4
C5P2
bit3
C4P4
C4P2
bit5
C6P4
C6P2
bit7
C8P4
C8P2
bit6
C7P4
C7P2
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
16 channel Digital output(0.5A)
System power supply and load power
supply independently
short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
Two channels per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
EE
* DeviceNet module Power supply 7/8” 4pins
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 19: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/19.jpg)
17 GSEE TECH
GX_DI8DO8 compact modules
Ordering data
GXDP-DI8DO8 GXDN-DI8DO8
GXPI-DI8DO8 GXEC-DI8DO8 GXEI-DI8DO8 GXEN-DI8DO8
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded
8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
8(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionInputNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentOutputNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Input M12 x 1
Byte
DI0
DO0
bit0
C1P4
C5P4
bit1
C1P2
C5P2
bit2
C2P4
C6P4
bit4
C3P4
C7P4
bit3
C2P2
C6P2
bit5
C3P2
C7P2
bit7
C4P2
C8P2
bit6
C4P4
C8P4
Output M12 x 1
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Digital input/output
MODBUS TCP/IP
PW
R
I0 I1 I2 I3 I4 I 5 I6 I7
O6 O7O4 O5O2 O3O0 O1
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
8 channel Digital input(PNP)
8 channel Digital output(0.5A)
System power supply and load power
supply independently
Short circuit、overload、Reverse
polarity protection
Channel-related diagnostics
Two channels per connector
Fibre-glass reinforced PA6 housing
Vibration and shock-resistant
Encapsulated module electronics
Metal connector
Degree of protection IP67
EE
* DeviceNet module Power supply 7/8” 4pins
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 20: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/20.jpg)
18 GSEE TECH
GX_DIO16 Configurable compact modules
Ordering data
GXDP-DIO16
GXPI-DIO16 GXEC-DIO16 GXEI-DIO16 GXEN-DIO16
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 180 mA
M12, A-coded
16(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
16(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionInputNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentOutputNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Input M12 x 1
Byte
0
1
bit0
C1P4
C1P2
bit1
C2P4
C2P2
bit2
C3P4
C3P2
bit4
C5P4
C5P2
bit3
C4P4
C4P2
bit5
C6P4
C6P2
bit7
C8P4
C8P2
bit6
C7P4
C7P2
Digital output
Digital input
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Output M12 x 1
MODBUS TCP/IP
PW
R
IO0
IO8
IO1
IO9
IO2
IO10
IO3
IO11
IO7
IO15
IO6
IO14
IO5
IO13
IO4
IO12
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
Byte
0
1
bit0
C1P4
C1P2
bit1
C2P4
C2P2
bit2
C3P4
C3P2
bit4
C5P4
C5P2
bit3
C4P4
C4P2
bit5
C6P4
C6P2
bit7
C8P4
C8P2
bit6
C7P4
C7P2
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
16 configurable digital channelsInput/output adaptivePNP inputs / outputs 0.5 A System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connectorFibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 21: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/21.jpg)
19 GSEE TECH
GX-DI8AI4 combined modules
Ordering data
GXDP-DI8AI4
GXPI-DI8AI4 GXEC-DI8AI4 GXEI-DI8AI4
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded
8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
4approx. 100Ohm, difference input<200 mA/port0 / 4...20mA12bit (0-4095)/ 16bit(0-32767)approx. 10ms per channel24VDC(18…30.2V)
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput resistanceSensor supplyMeasuring rangesResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Digital input M12 x 1
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Analog input M12 x 1
Pin 1 +24VPin 2 A +Pin 3 0VPin 4 A -3
2
5
1
4
2
1
4
34
1
32
2
4
1
3
Digital input
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
PW
R
I0 I1 I2 I3 I4 I5 I6 I7
A3A2A1A0
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
Add..
Ch.
Byte0
C5(A0)
Byte1 Byte2
C6(A1)
Byte4
C7(A2)
Byte3 Byte5 Byte7Byte6
C8(A3)
Analog input
* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.
8 channel Digital input(PNP)4 channel analog current inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 22: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/22.jpg)
20 GSEE TECH
GX_DI8AI4-0010 combined modules
Ordering data
GXDP-DI8AI4-0010
GXPI-DI8AI4-0010 GXEC-DI8AI4-0010 GXEI-DI8AI4-0010
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded
8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
4< 100 kΩ<120 mA/port-10/0 ... +10 VDC12bit (0-4095)/ 16bit(0-32767)approx. 5ms per channel24VDC(18…30.2V)
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput resistanceSensor supplyMeasuring rangesResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
M12 Digital input
M12 Analog input
Pin 1 +24VPin 2 V +Pin 3 0VPin 4 V -3
2
5
1
4
2
1
4
34
1
32
2
4
1
3
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
PW
R
I0 I1 I2 I3 I4 I5 I6 I7
A3A2A1A0226
62
6.3
24
39.7
2131 2 3 4
8765
BU
S
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Digital input
* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
Add..
Ch.
Byte0
C5(A0)
Byte1 Byte2
C6(A1)
Byte4
C7(A2)
Byte3 Byte5 Byte7Byte6
C8(A3)
Analog input
* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.
8 channel Digital input(PNP)4 channel analog Voltage inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnostics Two channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 23: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/23.jpg)
21 GSEE TECH
GX_DI8AI4-0020 combined modules
Ordering data
GXDP-DI8AI4-0020
GXPI-DI8AI4-0020 GXEC-DI8AI4-0020 GXEI-DI8AI4-0020
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded
8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
4Pt100, Pt200, Pt500, Pt1000, Ni100, Ni10000...100Ω, 0...200Ω, 0...400Ω, 0...1000Ω< 0.2 %0.05 %< 300 ppm/°C of full scale16Bit16 bit signed integerapprox. 20ms per channel
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput type
Basic fault limit at 23 °CRepeatabilityTemperature coeffi cientResolutionMeasured-value displayCycle time Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Digital input M12 x 1
Analog input M12 x 1
3
2
5
1
4
Pin 1 redPin 2 redPin 3 whitePin 4 whitePin 5 n.c.
2
1
4
3
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
PW
R
I0 I1 I2 I3 I4 I 5 I6 I7
A3A2A1A0
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Digital input
* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
Add..
Ch.
Byte0
C5(A0)
Byte1 Byte2
C6(A1)
Byte4
C7(A2)
Byte3 Byte5 Byte7Byte6
C8(A3)
Analog input
* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.
8 channel Digital input(PNP)4 channel analog RTD inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 24: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/24.jpg)
22 GSEE TECH
GX_DI8AI4-0030 combined modules
Ordering data
GXDP-DI8AI4-0030
GXPI-DI8AI4-0030 GXEC-DI8AI4-0030 GXEI-DI8AI4-0030
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded
8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
4types E / S / J / T / K / B / N / C / R / L< 0.2 %0.05 %<300 ppm/°C16bit16 bit signed integerapprox. 20ms per channel
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput typeBasic fault limit at 23 °CRepeatabilityTemperature coeffi cientResolutionMeasured-value displayConversion time Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Digital input M12 x 1
Analog input M12 x 1
3
2
5
1
4
Pin 1 PT1000Pin 2Pin 3 PT1000Pin 4 TH-Pin 5 n.c.
1
32
4
TH+
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
PW
R
I0 I1 I2 I 3 I4 I5 I6 I7
A3A2A1A0
226
62
6.3
24
39.7
2131 2 3 4
8765
BU
S
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Digital input
* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
Add..
Ch.
Byte0
C5(A0)
Byte1 Byte2
C6(A1)
Byte4
C7(A2)
Byte3 Byte5 Byte7Byte6
C8(A3)
Analog input
* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.
8 channel Digital input(PNP)4 channel analog TC inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 25: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/25.jpg)
23 GSEE TECH
GX_DI8AI4-0090 combined modules
Ordering data
GXDP-DI8AI4-0090
GXPI-DI8AI4-0090 GXEC-DI8AI4-0090 GXEI-DI8AI4-0090
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA
M12, A-coded
8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
4approx. 100Ohm, difference input<200 mA/port0 / 4...20mA(I) 、-10/0 ... +10 VDC(U)12bit (0-4095)/ 16bit(0-32767)approx. 10ms per channel24VDC(18…30.2V)
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog input(I/U)Number of channelsInput resistanceSensor supplyMeasuring rangesResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
Power supply 7/8”
Digital input M12 x 1
Analog input M12 x 1
Pin 1 +24VPin 2 V +Pin 3 0VPin 4 V -3
2
5
1
4
2
1
4
34
1
32
2
4
1
3
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Digital input
* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
Add..
Ch.
Byte0
C5(A0)
Byte1 Byte2
C6(A1)
Byte4
C7(A2)
Byte3 Byte5 Byte7Byte6
C8(A3)
Analog input
* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.
PW
R
I0 I1 I2 I3 I4 I5 I6 I7
A3A2A1A0226
62
6.3
24
39.7
2131 2 3 4
8765
BU
S
8 channel Digital input(PNP)4 channel analog current/Voltage inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 26: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/26.jpg)
GX_DIO8AO4-0009 combined modules
Technical specifications
24 V DC (18…30.2 V), acc. to EN61131-2< 180 mA
M12, A-coded
8 (for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA
8 (DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus
Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionInputNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentOutputNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolation
Input M12 x 1
Output M12 x 1
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Digital input
Byte
0
bit0
C1P4
bit1
C1P2
bit2
C2P4
bit4
C3P4
bit3
C2P2
bit5
C3P2
bit7
C4P2
bit6
C4P4
Digital output
24 GSEE TECH
PW
R
A 3A 2A 1A 0
226
62
6.3
24
39.7
213
1 2 3 48765
BU
S
IO0
IO1
IO2
IO3
IO4
IO5
IO6
IO7
"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.
8 configurable digital channels4 channel analog current/Voltage outputsPNP inputs / outputs 0.5 A System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connectorFibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67
7/8"; 5-pole; U B max. 9 A, UL max. 9 A
![Page 27: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/27.jpg)
Ordering data
GXDP-DIO8AO4-0009
GXPI-DIO8AO4-0009 GXEC-DIO8AO4-0009 GXEI-DIO8AO4-0009
4≥ 500Ohm(I) / ≥ 1 kΩ(U)0 / 4...20mA(I) 、-10/0 ... +10 VDC(U)12Bit(0-4095)/16Bit(0-32767)approx. 10ms per channel24VDC(18…30.2V)
226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 °Caccording to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE
Analog input(I/U)Number of channelsResistanceOutput typeResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals
* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.
Analog output M12 x 1
Pin 1 +24VPin 2 A +Pin 3 0VPin 4 A -3
2
5
1
4
25 GSEE TECH
GX_DIO8AO4-0009 combined modules
Power supply 7/8”
Add..
Ch.
Byte0
C5(A0)
Byte1 Byte2
C6(A1)
Byte4
C7(A2)
Byte3 Byte5 Byte7Byte6
C8(A3)
Analog output
* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.
![Page 28: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/28.jpg)
26 GSEE TECH
Connector(Ethernet/IPTM.ModbusTMTCP) Type NO. ID NO. Pinout
M12 Pre-mouldingRight angleMale
M12 Pre-mouldingRight angleFemale
M12 Pre-mouldingStraightMale
M12 Pre-mouldingStraightFemale
Standard1.WH/OR2.OR3.WH/GN4.N/C5.N/C6.GN7.N/C8.N/CCross1.WH/GN2.GN3.WH/OR4.N/C5.OR6.N/C7.N/C8.N/C
M12 ReceptacleFemale
M12 ReceptacleMale
RJ45 straight
RJ45 right angle Buckle up
RJ45 right angle Buckle down
45678312
EIK4-2M/F41EIK4-5M/F41EIK4-10M/F41
100172101001721110017212
100172151001721610017217
100172201001722110017222
100172251001722610017227
100173951001739610017397
100174001001740110017402
102500401025004110250042
102500501025005110250052
102500601025006110250062
EIZ4-2M/F41EIZ4-5M/F41EIZ4-10M/F41
EILK4-2M/F41EILK4-5M/F41EILK4-10M/F41
EILZ4-2M/F41EILZ4-5M/F41EILZ4-10M/F41
FEIK41-2M/F41FEIK41-5M/F41FEIK41-10M/F41
FEIZ41-2M/F41FEIZ41-5M/F41FEIZ41-10M/F41
RJ45S-2M/F41RJ45S-5M/F41RJ45S-10M/F41
TRJ45S-2M/F41TRJ45S-5M/F41TRJ45S-10M/F41
BRJ45S-2M/F41BRJ45S-5M/F41BRJ45S-10M/F41
Male
Female
1.WH/OR(+tx)2.WH/GN(+rx)3.OR(-tx)4.GN(-rx)
1
4
3
2
4
31
2
*Cross type:RJ45S-*M/F41-CRTRJ45S-*M/F41-CRBRJ45S-*M/F41-CR
Ø15
M12
x148.1
13
Ø15
M12
x1
55.821
Ø15M12x1
32
46
46
39.2
Ø15M12x1
18
M12×1
PG9
21.5
25
M12×1
PG9
20
53.5
41
34
41
34
Accessories
![Page 29: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/29.jpg)
27 GSEE TECH
Connector(PROFINET) Type NO. ID NO. Pinout
M12 Pre-mouldingRight angleMale
M12 Pre-mouldingRight angleFemale
M12 Pre-mouldingStraightMale
M12 Pre-mouldingStraightFemale
M12 ReceptacleFemale
M12 ReceptacleMale
RJ45 right angle Buckle up
RJ45 right angle Buckle down
EIK4-2M/F21EIK4-5M/F21EIK4-10M/F21
100173201001732110017322
100173251001732610017327
100173301001733110017332
100173351001733610017337
100174151001741610017417
100174201001742110017422
102500901025009110250092
102501001025010110250102
102501101025011110250112
EIZ4-2M/F21EIZ4-5M/F21EIZ4-10M/F21
EILK4-2M/F21EILK4-5M/F21EILK4-10M/F21
EILZ4-2M/F21EILZ4-5M/F21EILZ4-10M/F21
FEIK41-2M/F21FEIK41-5M/F21FEIK41-10M/F21
FEIZ41-2M/F21FEIZ41-5M/F21FEIZ41-10M/F21
SRJ45S-2M/F21SRJ45S-5M/F21SRJ45S-10M/F21
TRJ45-2M/F21TRJ45-5M/F21TRJ45-10M/F21
BRJ45-2M/F21BRJ45-5M/F21BRJ45-10M/F21
孔座
针座
1.Yellow(+tx)2.White(+rx)3.Orange(-tx)4.Blue(-rx)
1.YE2.OR3.WH4.N/C5.N/C6.BU7.N/C8.N/C
45678312
4
1
2
4
3
2
RJ45 straight Quick Unlock
Ø15
M12
x148.1
13
Ø15
M12
x1
55.821
Ø15M12x1
32
46
46
39.2
Ø15M12x1
18
M12×1
PG9
21.5
25
M12×1
PG9
20
41
34
41
34
49.8
3
1
Accessories
![Page 30: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/30.jpg)
28 GSEE TECH
Pinout
M12预铸直线孔座
Connector(EtherCAT) Type NO. ID NO.
1
4
3
2
4
31
2
M12 Pre-mouldingRight angleMale
M12 Pre-mouldingRight angleFemale
M12 Pre-mouldingStraightMale
M12 Pre-mouldingStraightFemale Female
Male
M12 ReceptacleFemale
M12 ReceptacleMale
18
M12×1
PG9
21.5
Ø15
M12
x1
55.821
Ø15
M12
x1
48.113
Ø15M12x1
32
46
46
39.2
Ø15M12x1
25
M12×1
PG9
20
1.Orange/White (+tx)2.Blue/White(+rx)3.Orange(-tx)4.Blue(-rx)
EIK4-2M/F230EIK4-5M/F230EIK4-10M/F230
100162651001626610016267
100162681001626910016270
EIZ4-2M/F230EIZ4-5M/F230EIZ4-10M/F230
100162711001628410016273
100162741001627510016276
100410571004105810041059
100410601004103710041038
EILK4-2M/F230EILK4-5M/F230EILK4-10M/F230
EILZ4-2M/F230EILZ4-5M/F230EILZ4-10M/F230
FEIK41-2M/F230FEIK41-5M/F230FEIK41-10M/F230
FEIZ41-2M/F230FEIZ41-5M/F230FEIZ41-10M/F230
Ø4.8
Ø4.8
Ø4.8
Ø4.8
Ø4.8
Ø4.8
Accessories
![Page 31: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/31.jpg)
29 GSEE TECH
Connector(EtherCAT) Type NO. ID NO. Pinout
RJ45 straight
RJ45 right angle Buckle up
RJ45 right angle Buckle down
45678312
53.5
41
34
41
34
102503741025037510250376
RJ45S-2M/F230RJ45S-5M/F230RJ45S-10M/F230
102503771025037810250379
102503801025038110250382
TRJ45S-2M/F230TRJ45S-5M/F230TRJ45S-10M/F230
BRJ45S-2M/F230BRJ45S-5M/F230BRJ45S-10M/F230
1.OR/WH2.OR3.BU/WH4.N/C5.N/C6.BU7.N/C8.N/C
Ø4.8
Ø4.8
Ø4.8
BuleWhite/BuleOrangeWhite/Orangee
JacketBraid
Foil
Insulation
F230
Suffix code
F23080°C 30Volts
Cable Type NO. Authentication
CS042671-*M
Data parameter JacketCable
parameters20 °C Conductor
resistance/insulatiMaterial、Colour
、Outer diameter
Shield
Foil/BraidUL/CSADESINA CE
4*26AWG
140 PO
PUR Yellow green4.8mm
Ω/km
Accessories
![Page 32: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/32.jpg)
30 GSEE TECH
Pinout
M12预铸直线孔座
Connector(EtherCAT) Type NO. ID NO.
1
4
3
2
4
31
2
M12 Pre-mouldingRight angleMale
M12 Pre-mouldingRight angleFemale
M12 Pre-mouldingStraightMale
M12 Pre-mouldingStraightFemale Female
Male
M12 ReceptacleFemale
M12 ReceptacleMale
18
M12×1
PG9
21.5
Ø15
M12
x1
55.821
Ø15
M12
x1
48.113
Ø15M12x1
32
46
46
39.2
Ø15M12x1
25
M12×1
PG9
20
Ø5.2
Ø5.2
Ø5.2
Ø5.2
Ø5.2
Ø5.2
1.Yellow(+tx)2.White(+rx)3.Orange(-tx)4.Blue(-rx)
EIK4-2M/F211EIK4-5M/F211EIK4-10M/F211
100162771001627810016279
100162801001628110016282
EIZ4-2M/F211EIZ4-5M/F211EIZ4-10M/F211
100162831001628410016285
100162861001628710016288
100410451004104610041047
100410481004104910041050
EILK4-2M/F211EILK4-5M/F211EILK4-10M/F211
EILZ4-2M/F211EILZ4-5M/F211EILZ4-10M/F211
FEIK41-2M/F211FEIK41-5M/F211FEIK41-10M/F211
FEIZ41-2M/F211FEIZ41-5M/F211FEIZ41-10M/F211
Accessories
![Page 33: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/33.jpg)
31 GSEE TECH
Connector(EtherCAT) Type NO. ID NO. Pinout
RJ45 straight
RJ45 right angle Buckle up
RJ45 right angle Buckle down
45678312
53.5
41
34
41
34
102503831025038410250385
RJ45S-2M/F211RJ45S-5M/F211RJ45S-10M/F211
102503861025038710250388
102503891025039010250391
TRJ45S-2M/F211TRJ45S-5M/F211TRJ45S-10M/F211
BRJ45S-2M/F211BRJ45S-5M/F211BRJ45S-10M/F211
1.YE2.OR3.WH4.N/C5.N/C6.BU7.N/C8.N/C
JacketBraid
Foil
Insulation
OrangeYellowBuleWhite
F211
Suffix code
F21180°C 300 Volts
Cable Type NO. Authentication
CS042461-*M
Data parameter JacketCable
parameters20 °CConductor
resistance/insulationMaterial、Colour
、Outer diameter
Shield
Foil/BraidUL/CSADESINA CE
4*24AWG 91 PO
PVC Yellow green 5.4mmΩ/km
Accessories
![Page 34: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/34.jpg)
32 GSEE TECH
Field wirable connector(Ethernet) Type NO. ID NO. Features Pinout
M12 Right angleMale
M12 Right angleFemale
M12 StraightMale
M12 StraightFemale
RJ45 StraightMetal Field wirable
12345678
AWG27-AWG22Cable parametersCable diameter:5.5-9 mm70°C, 125V, 1.5 A10/100Mbps
4A,250V,-40 ~ +85°CMatch with4-pin D-codeM12 pre-moulding/receptacle connector
EK4238-0/9
EZ4238-0/9
ELK4238-0/9
ELZ4238-0/9
RJ45/HM
Female
Male4
3
2
1
4
1
2
3
10091220
10091230
10091221
10091231
10250161
Accessories
![Page 35: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/35.jpg)
100120001001200110012002
100120101001201110012012
100120201001202110012022
100120301001203110012032
100120401001204110012042
100120701001207110012072
Connector(Profibus-DP) Features
M12 Pre-mouldingStraight FemaleB-code, Braid
Type NO.
EPK5-2MEPK5-5MEPK5-10M
ID NO.
1=n.c
2=GN(Bus A)
3=n.c
4=RD(Bus B)
5=n.c
1
2
3
45
Pinout
1=n.c
2=GN(Bus A)
3=n.c
4=RD(Bus B)
5=n.c
48.110.8
15
M12x1
32
15
46
38
M12x1
55.818
15
M12x1
4638
39.2
15M12x1
48.110.8
15
55.818
15
M12x1
M12x1
4638
39.2
15
32
15
4638
M12x1 M12x1
M12 Pre-mouldingRight angle FemaleB-code, Braid
M12 Pre-mouldingStraight MaleB-code, Braid
M12 Pre-mouldingRight angle MaleB-code, Braid
M12 Pre-mouldingFemale/MaleB-code, Braid
M12 Pre-mouldingFemale/MaleB-code, Braid
EPLK5-2MEPLK5-5MEPLK5-10M
EPZ5-2MEPZ5-5MEPZ5-10M
EPLZ5-2MEPLZ5-5MEPLZ5-10M
EPK5 EPZ5-2MEPK5 EPZ5-5MEPK5 EPZ5-10M
EPLK5 EPLZ5-2MEPLK5 EPLZ5-5MEPLK5 EPLZ5-10M
1
2
3
4 5
1
2
3
451=n.c
2=GN(Bus A)
3=n.c
4=RD(Bus B)
5=n.c1
2
3
4 5
58100251Profibus-DP CableTwo core Multi StrandFoil/Braid
CS022280-*M RD
VT
7.6
GN
10091200EK5228-0/9
1
2
3
4 5
1
2
3
4510091210EZ5228-0/9
M12x1
57.4 19.6
M12x1
2062
4A,250V,-40 ~ +85°CMatch with5-pin B-codeM12 pre-moulding/receptacle connectorFemale
4A,250V,-40 ~ +85°CMatch with5-pin B-codeM12 pre-moulding/receptacle connectorMale
10081001
10085000
Profibus-DP Splitter EPK5-2EPZ5-V
Profibus-DPTermination resistors
EPZ5-TR
234.58
25
M12x1
M12x1
3818
M12x1
M12x1
4322.1
14.216.4
12
3
45
2xM12 Male
3
1=5VDC2=Bus-A3=GND4=Bus-B5=Shield1
2
4 5
1xM12 Female
1
2
345
390
390
220
1/4W
1/4W
1/4W
1=5VDC2=Bus-A
3=GND4=Bus-B 5=Shield
1xM12 Male
33 GSEE TECH
Accessories
![Page 36: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/36.jpg)
100130001001300110013002
100130101001301110013012
100130201001302110013022
100130301001303110013032
100130401001304110013042
100130701001307110013072
Connector(Devicenet) Features
M12 Pre-mouldingStraight FemaleA-code, Thin Cable
Type NO.
ENK5-2MENK5-5MENK5-10M
ID NO.
1=Sheild
2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)
1=Sheild
2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)
1=Sheild
2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)
Pinout
M12 Pre-mouldingRight angle FemaleA-code, Thin Cable
M12 Pre-mouldingStraight MaleA-code, Thin Cable
M12 Pre-mouldingRight angle MaleA-code, Thin Cable
M12 Pre-mouldingFemale/MaleA-code, Thin Cable
M12 Pre-mouldingFemale/MaleA-code, Thin Cable
ENLK5-2MENLK5-5MENLK5-10M
ENZ5-2MENZ5-5MENZ5-10M
ENLZ5-2MENLZ5-5MENLZ5-10M
ENK5 ENZ5-2MENK5 ENZ5-5MENK5 ENZ5-10M
ENLK5 ENLZ5-2MENLK5 ENLZ5-5MENLK5 ENLZ5-10M
48.110.8
15
M12x1
32
15
4638
M12x1
55.818
15
M12x1
4638
39.2
15M12x1
55.818
15
M12x148.110.8
15
M12x1
4638
39.2
15M12x1
32
15
4638
M12x1
1
2
3
45
1
2
3
4 5
1
2
3
45
1
2
3
4 5
1008501010085011
Terminating resistorM12x1 MaleM12x1 Female
ENZ5-TRENK5-TR
28
17.5
31.5
7/8-16UN
7/8-16UNM12x1
7337.4
26
2
1x 7/8"Female
1
345
1=Shield2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)
1x 7/8"Male12
34
5
1xM12Female
1
2
3
45
M12Male
M12Female
1
2
3
4 5
1=Shield2=RD(V+)3=BK(V-)
4=WH(CAN H)5=BU(CAN L)
1201/4W
1201/4W
2
5
1
48.510.8
15
M12x1
M12x1
15
1855.8
DeviceNET T type MNZ5-ENK5-MNK5 10082001
34 GSEE TECH
Accessories
![Page 37: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/37.jpg)
100310001003100110031002
100310101003101110031012
100310201003102110031022
100310301003103110031032
100310401003104110031042
100310701003107110031072
582002515821025158220251
Connector(Devicenet) Features
7/8’’Pre-mouldingStraight FemaleThick Cable
Type NO.
MNK5-2MMNK5-5MMNK5-10M
ID NO. Pinout
7/8’’Pre-mouldingRight angle FemaleThick Cable
7/8’’Pre-mouldingStraight MaleThick Cable
7/8’’Pre-mouldingRight angle MaleThick Cable
7/8’’Pre-mouldingFemale/MaleThick Cable
7/8’’Pre-mouldingFemale/MaleThick Cable
MNLK5-2MMNLK5-5MMNLK5-10M
MNZ5-2MMNZ5-5MMNZ5-10M
MNLZ5-2MMNLZ5-5MMNLZ5-10M
MNK5 MNZ5-2MMNK5 MNZ5-5MMNK5 MNZ5-10M
MNLK5 MNLZ5-2MMNLK5 MNLZ5-5MMNLK5 MNLZ5-10M
CS041580-*MCS041680-*MCS042280-*M
Thick CableMid CableThin Cable
7/8-16UN20.5
17.5
11
65
29
27
7/8-16UN
51.25
4030.55
277/8-16UN
4111
17.5
51.25
43.534
277/8-16UN
4111
17.5
1
2
34
5
1
2
34
5
1=Shield
2=RD(V+)
3=BK(V-)
4=WH(CAN H)
5=BU(CAN L)
1=Shield
2=RD(V+)
3=BK(V-)
4=WH(CAN H)
5=BU(CAN L)
20.5
11 7/8-16UN
2717.5
68.536
7/8-16UN
27
68.536
27
7/8-16UN
65
29
51.25
40
30.55
27
7/8-16UN
41
51.25
43.534
277/8-16UN
41
1
23
4
5
1=Shield
2=RD(V+)
3=BK(V-)
4=WH(CAN H)
5=BU(CAN L)
1
23
4
5
BlueWhiteBlackRed Power
Data
10082000DeviceNET T type MNZ5-2MNK5
1008502010085021
Terminating resistor7/8” Male7/8” Female
MNZ5-TRMNK5-TR
28
17.5
34.8
7/8-16UN
7/8-16UN
37.473
7/8-16UN26
26
7/8-16UN48.5
26
36
7/8-16UN
26
32
44.5
7/8"Male
7/8"Female1
23
45
1=Shield2=RD(V+)3=BK(V-)
4=WH(CAN H)5=BU(CAN L)
1201/4W
1201/4W
1x7/8"Male
1
23
4
5
1
23
45
1=Shield2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)
2x7/8"Female
35 GSEE TECH
Accessories
![Page 38: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/38.jpg)
100330001003300110033002
100330101003301110033012
100330201003302110033022
100330301003303110033032
100330401003304110033042
100330701003307110033072
Connector(Power Supply) Features
7/8’’Pre-mouldingStraight Female
Type NO.
MK5-2MMK5-5MMK5-10M
ID NO. Pinout
7/8’’Pre-mouldingRight angle Female
7/8’’Pre-mouldingStraight Male
7/8’’Pre-mouldingRight angle Male
7/8’’Pre-mouldingFemale/Male
7/8’’Pre-mouldingFemale/Male
MLK5-2MMLK5-5MMLK5-10M
MZ5-2MMZ5-5MMZ5-10M
MLZ5-2MMLZ5-5MMLZ5-10M
MK5 MZ5-2MMK5 MZ5-5MMK5 MZ5-10M
MLK5 MLZ5-2MMLK5 MLZ5-5MMLK5 MLZ5-10M
1
2
34
5
1
2
34
5
1
2
34
5
7/8-16UN15.5
26
2950.5
18
8.71=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)
1=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)
1=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)
51.25
4030.55
418.7
17.5
267/8-16UN
7/8-16UN
26
8.7
3654
15.5
51.25
43.534
418.7
17.5
267/8-16UN
34
5
2
1
1=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)
1=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)
34
5
2
1
34
5
2
1
1
2
34
51=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)3
4
5
2
1
7/8-16UN
26
8.7
3654
15.57/8-16UN15.5
26
2950.5
18
51.25
4030.55
41
267/8-16UN
51.25
43.534
418.7
267/8-16UN
28
17.5
34.8
7/8-16UN
7/8-16UN
7337.4
26
7/8-16UN26
100840007/8”T type power connector 5pins
MZ5-2MK5 2x7/8"Female
1x7/8"Male
1
2
34
51=BK (GND)
2=BU (GND)
3=GNYE (PE)
4=BN (US)
5=WH (UA)3
4
5
2
1
36 GSEE TECH
Accessories
![Page 39: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/39.jpg)
37 GSEE TECH
Accessories
Connector(I/O) Features Type NO. ID NO. Pinout
100110601001106110011062
100110701001107110011072
M12 Pre-mouldingStraight Female3pinsA-code
EZ3-2M/P00EZ3-5M/P00EZ3-10M/P00
M12 Pre-mouldingStraight Female4pinsA-code
EZ4-2M/P00EZ4-5M/P00EZ4-10M/P00
100110901001109110011092
M12 Pre-mouldingRight angle Female3pinsA-code
ELZ3-2M/P00ELZ3-5M/P00ELZ3-10M/P00
3 BU
4 BK
1 BN
5 GY
2 WH
3 BU
4 BK
1 BN
48.818
15
M12x1
35.528.6
32.7
15M12x1
3 BU
4 BK
1 BN
5 GY
2 WH
3 BU
4 BK
1 BN
2 WH
3 BU
4 BK
1 BN
2 WH
3 BU
4 BK
1 BN
100115101001151110011512
M12 Pre-mouldingStraight Female5pinsA-code
EZ5-2M/P00EZ5-5M/P00EZ5-10M/P00
100111001001110110011102
M12 Pre-mouldingRight angle Female4pinsA-code
ELZ4-2M/P00ELZ4-5M/P00ELZ4-10M/P00
100115301001153110011532
M12 Pre-mouldingRight angle Female5pinsA-code
ELZ5-2M/P00ELZ5-5M/P00ELZ5-10M/P00
![Page 40: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/40.jpg)
38 GSEE TECH
Accessories
Connector(I/O) Features Type NO. ID NO. Pinout
100111201001112110011122
100111301001113110011132
100115501001155110011552
M12 Pre-mouldingFemale/Male3pinsA-code
EK3 EZ3-2M/P00EK3 EZ3-5M/P00EK3 EZ3-10M/P00
M12 Pre-mouldingFemale/Male4pinsA-code
EK4 EZ4-2M/P00EK4 EZ4-5M/P00EK4 EZ4-10M/P00
100115401001154110011542
M12 Pre-mouldingFemale/Male5pinsA-code
EK5 EZ5-2M/P00EK5 EZ5-5M/P00EK5 EZ5-10M/P00
100111601001116110011162
M12 Pre-mouldingFemale/Male4pinsA-code
ELK4 ELZ4-2M/P00ELK4 ELZ4-5M/P00ELK4 ELZ4-10M/P00
M12 Pre-mouldingFemale/Male5pinsA-code
ELK5 ELZ5-2M/P00ELK5 ELZ5-5M/P00ELK5 ELZ5-10M/P00
2 WH*
3 BU
4 BK
1 BN
2 WH*
3 BU
4 BK
1 BN
2 WH
3 BU
4 BK
1 BN
5 GY
5 GY
2 WH
3 BU
4 BK
1 BN
40.710.8
15
M12x1
48.818
15
M12x1
2 WH*
3 BU
4 BK
1 BN
2 WH*
3 BU
4 BK
1 BN
2 WH
3 BU
4 BK
1 BN
5 GY
5 GY
2 WH
3 BU
4 BK
1 BN
35.528.6
32.7
15M12x1
M12x1
24.9
15
35.5
28.6
100111501001115110011152
M12 Pre-mouldingFemale/Male3pinsA-code
ELK3 ELZ3-2M/P00ELK3 ELZ3-5M/P00ELK3 ELZ3-10M/P00
![Page 41: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/41.jpg)
39 GSEE TECH
Accessories
Features Type NO. ID NO. Pinout
10092101
10092102
MK5211-0/11
Nylon+Glass fiber/BlackCast aluminum coupling nutsPG13.5 cable glandAccepts 10-12 mm cable diameterScrew terminals 85°C,250V,9 A
MK5211-0/13.5
10092121Nylon+Glass fiber/BlackCast aluminum coupling nutsPG11 cable glandAccepts 8-10 mm cable diameterScrew terminals 85°C,250V,9 A
MZ5211-0/11
5pins 7/8’’ Field wirable connector (power supply / DeviceNET )
Nylon+Glass fiber/BlackCast aluminum coupling nutsPG11 cable glandAccepts 8-10 mm cable diameterScrew terminals 85°C,250V,9 A
8527
7/8-16UN
8827
7/8-16UN
1
23
4
5
1
2
3
4
510092122Nylon+Glass fiber/Black
Cast aluminum coupling nutsPG11 cable glandAccepts 10-12 mm cable diameterScrew terminals 85°C,250V,9 A
MZ5211-0/13.5
![Page 42: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/42.jpg)
40 GSEE TECH
Accessories
10091020
10091021EZ4112-0/9
10091022EZ5112-0/7
10091023EZ5112-0/9
Field wireable connector Features Type NO.
EZ4112-0/7
ID NO. Pinout
1
2
3
45
61 19.6
M12x1
10091030
10091031ELZ4112-0/9
10091032ELZ5112-0/7
10091033ELZ5112-0/9
ELZ4112-0/7
1
2
3
4
1
2
3
45
41.9 19.6
M12x1
40
1
2
3
4
PBT, Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A
PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A
PBT, Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A
PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A
PBT, Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A
PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A
PBT,Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A
PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A
![Page 43: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/43.jpg)
41 GSEE TECH
Accessories
10091101
10091111EZ4112-1/11
EK4112-1/11
1
2
3
4
1
2
3
4
Field wireable connector Features
PBT,Black,nickel plated brasscoupling nutAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A
Type NO. ID NO. Pinout
59 19.6
M12x1
63 20
M12x1
PBT, Black, nickel plated brasscoupling nutAccepts 2*(3-5) mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A
101130001011300110113002
EZ4-TH-2M/P00EZ4-TH-5M/P00EZ4-TH-10M/P00
10091800For BL67-2AI-TC, M12 x 1 roundconnector, fi eld wirable, screw-terminal connection,integrated Pt1000 sensor for cold junction point compensation
EZ4112-0/7-TH
61 19.6
M12x13
21
4
1
3
TC
2
4
PT1000
3
21
4
1BN
3BU
TC
2WH
4BK
PT1000
Features Type NO. ID NO. PinoutThe cold junction point compensation
For BL67-2AI-TC, M12 x 1 roundconnector, fi eld wirable, screw-terminal connection,integrated Pt1000 sensor for cold junction point compensation
61 19.6
M12x1
![Page 44: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/44.jpg)
42 GSEE TECH
102501121025011010250111102503911025038210250062102503891025038010250060102503901025038110250061581002515820025158210251582202511001732210016279100162671001721210017320100162771001626510017210100173211001627810016266100172111001733210016285100162731001722210017330100162831001627110017220100173311001628410016284100172211001733710016288100162761001722710017335100162861001627410017225100173361001628710016275100172261001732710016282100162701001721710017325100162801001626810017215100173261001628110016269
027027027031029026031029026031029026033035035035027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028
BRJ45-10M/F21BRJ45-2M/F21BRJ45-5M/F21BRJ45S-10M/F211BRJ45S-10M/F230BRJ45S-10M/F41BRJ45S-2M/F211BRJ45S-2M/F230BRJ45S-2M/F41BRJ45S-5M/F211BRJ45S-5M/F230BRJ45S-5M/F41CS022280-*MCS041580-*MCS041680-*MCS042280-*MEIK4-10M/F21EIK4-10M/F211EIK4-10M/F230EIK4-10M/F41EIK4-2M/F21EIK4-2M/F211EIK4-2M/F230EIK4-2M/F41EIK4-5M/F21EIK4-5M/F211EIK4-5M/F230EIK4-5M/F41EILK4-10M/F21EILK4-10M/F211EILK4-10M/F230EILK4-10M/F41EILK4-2M/F21EILK4-2M/F211EILK4-2M/F230EILK4-2M/F41EILK4-5M/F21EILK4-5M/F211EILK4-5M/F230EILK4-5M/F41EILZ4-10M/F21EILZ4-10M/F211EILZ4-10M/F230EILZ4-10M/F41EILZ4-2M/F21EILZ4-2M/F211EILZ4-2M/F230EILZ4-2M/F41EILZ4-5M/F21EILZ4-5M/F211EILZ4-5M/F230EILZ4-5M/F41EIZ4-10M/F21EIZ4-10M/F211EIZ4-10M/F230EIZ4-10M/F41EIZ4-2M/F21EIZ4-2M/F211EIZ4-2M/F230EIZ4-2M/F41EIZ4-5M/F21EIZ4-5M/F211EIZ4-5M/F230
100172161001112210011120100111211001113210011130100111311009110110091220100115421001154010011541100912001001115210011150100111511001116210011160100111611009122110011552100115501001155110011092100110901001109110011102100910301009103110091231100111001001110110011532100910321009103310011530100115311001304210013040100130411001300210013000100130011008501110013072100130701001307110013012100130101001301110013032100130301001303110013022100130201001302110085010100120421001204010012041100120021008100110012000
026038038038038038038041032038038038033038038038038038038032038038038037037037037040040032037037037040040037037034034034034034034034034034034034034034034034034034034034034033033033033033033
EIZ4-5M/F41EK3 EZ3-10M/P00EK3 EZ3-2M/P00EK3 EZ3-5M/P00EK4 EZ4-10M/P00EK4 EZ4-2M/P00EK4 EZ4-5M/P00EK4112-1/11EK4238-0/9EK5 EZ5-10M/P00EK5 EZ5-2M/P00EK5 EZ5-5M/P00EK5228-0/9ELK3 ELZ3-10M/P00ELK3 ELZ3-2M/P00ELK3 ELZ3-5M/P00ELK4 ELZ4-10M/P00ELK4 ELZ4-2M/P00ELK4 ELZ4-5M/P00ELK4238-0/9ELK5 ELZ5-10M/P00ELK5 ELZ5-2M/P00ELK5 ELZ5-5M/P00ELZ3-10M/P00ELZ3-2M/P00ELZ3-5M/P00ELZ4-10M/P00ELZ4112-0/7ELZ4112-0/9ELZ4238-0/9ELZ4-2M/P00ELZ4-5M/P00ELZ5-10M/P00ELZ5112-0/7ELZ5112-0/9ELZ5-2M/P00ELZ5-5M/P00ENK5 ENZ5-10MENK5 ENZ5-2MENK5 ENZ5-5MENK5-10MENK5-2MENK5-5MENK5-TRENLK5 ENLZ5-10MENLK5 ENLZ5-2MENLK5 ENLZ5-5MENLK5-10MENLK5-2MENLK5-5MENLZ5-10MENLZ5-2MENLZ5-5MENZ5-10MENZ5-2MENZ5-5MENZ5-TREPK5 EPZ5-10MEPK5 EPZ5-2MEPK5 EPZ5-5MEPK5-10MEPK5-2EPZ5-VEPK5-2M
Index
Type NO. ID NO. Page number Type NO. ID NO. Page number
![Page 45: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/45.jpg)
43 GSEE TECH
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
033033033033033033033033033033033033033033037037037037040041040041032037037041041041037040040033037037027030028026027030028026027030028026027030028026027030028026027030028026012010017016014
EPK5-5MEPLK5 EPLZ5-10MEPLK5 EPLZ5-2MEPLK5 EPLZ5-5MEPLK5-10MEPLK5-2MEPLK5-5MEPLZ5-10MEPLZ5-2MEPLZ5-5MEPZ5-10MEPZ5-2MEPZ5-5MEPZ5-TREZ3-10M/P00EZ3-2M/P00EZ3-5M/P00EZ4-10M/P00EZ4112-0/7EZ4112-0/7-THEZ4112-0/9EZ4112-1/11EZ4238-0/9EZ4-2M/P00EZ4-5M/P00EZ4-TH-10M/P00EZ4-TH-2M/P00EZ4-TH-5M/P00EZ5-10M/P00EZ5112-0/7EZ5112-0/9EZ5228-0/9EZ5-2M/P00EZ5-5M/P00FEIK41-10M/F21FEIK41-10M/F211FEIK41-10M/F230FEIK41-10M/F41FEIK41-2M/F21FEIK41-2M/F211FEIK41-2M/F230FEIK41-2M/F41FEIK41-5M/F21FEIK41-5M/F211FEIK41-5M/F230FEIK41-5M/F41FEIZ41-10M/F21FEIZ41-10M/F211FEIZ41-10M/F230FEIZ41-10M/F41FEIZ41-2M/F21FEIZ41-2M/F211FEIZ41-2M/F230FEIZ41-2M/F41FEIZ41-5M/F21FEIZ41-5M/F211FEIZ41-5M/F230FEIZ41-5M/F41GXDN-DI16GXDN-DI8GXDN-DI8DO8GXDN-DO16GXDN-DO8
A2060001A2060048A2060036A2060040A2060008A2060081A2060069A2060073A2060077A2060002A2060062A2060088A2060004A2060003A2060006A2060045A2060031A2060037A2060041A2060066A2060082A2060070A2060074A2060078A2060034A2060063A2060086A2060058A2060051A2060054A2060046A2060029A2060038A2060042A2060067A2060083A2060071A2060075A2060079A2060032A2060064A2060087A2060059A2060052A2060055A2060047A2060030A2060039A2060043A2060061A2060065A2060060A2060053A2060056A2060016A2060049A2060020A2060044A2060068A2060084A2060072A2060076A2060080
012013010011019023020021022017018024016014015012013010011019023020021022017018024016014015012013010011019023020021022017018024016014015012013010011017018016014015012013010011019023020021022
GXDP-DI16GXDP-DI16-1000GXDP-DI8GXDP-DI8-1000GXDP-DI8AI4GXDP-DI8AI4-0090GXDP-DI8AI4-0010GXDP-DI8AI4-0020GXDP-DI8AI4-0030GXDP-DI8DO8GXDP-DIO16GXDP-DIO8AO4-0009GXDP-DO16GXDP-DO8GXDP-DO8-0100GXEC-DI16GXEC-DI16-1000GXEC-DI8GXEC-DI8-1000GXEC-DI8AI4GXEC-DI8AI4-0090 GXEC-DI8AI4-0010GXEC-DI8AI4-0020GXEC-DI8AI4-0030GXEC-DI8DO8GXEC-DIO16GXEC-DIO8AO4-0009GXEC-DO16GXEC-DO8GXEC-DO8-0100GXEI-DI16GXEI-DI16-1000GXEI-DI8GXEI-DI8-1000GXEI-DI8AI4GXEI-DI8AI4-0090GXEI-DI8AI4-0010GXEI-DI8AI4-0020GXEI-DI8AI4-0030GXEI-DI8DO8GXEI-DIO16GXEI-DIO8AO4-0009GXEI-DO16GXEI-DO8GXEI-DO8-0100GXEN-DI16GXEN-DI16-1000GXEN-DI8GXEN-DI8-1000GXEN-DI8DO8GXEN-DIO16GXEN-DO16GXEN-DO8GXEN-DO8-0100GXPI-DI16GXPI-DI16-1000GXPI-DI8GXPI-DI8-1000GXPI-DI8AI4GXPI-DI8AI4-0090GXPI-DI8AI4-0010GXPI-DI8AI4-0020GXPI-DI8AI4-0030
Index
Type NO. ID NO. Page number Type NO. ID NO. Page number
![Page 46: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/46.jpg)
44 GSEE TECH
Index
Type NO. ID NO. Page number Type NO. ID NO. Page number A2060022A2060025A2060085A2060023A2060017A2060057100330421003304010033041100330021009210110092102100330001003300110033072100330701003307110033012100330101003301110033032100330301003303110031042100310401003104110031002100310001003100110085021100310721003107010031071100310121003101010031011100310321003103010031031100310221003102010082000100310211008200110085020100330221009212110092122100330201008400010033021100912991025038510250376102500421025038310250374102500401025038410250375102500411025009210250090
017018024016014015036036036036039039036036036036036036036036036036036035035035035035035035035035035035035035035035035035035035035034035036039039036036036032031029026031029026031029026031029
GXPI-DI8DO8GXPI-DIO16GXPI-DIO8AO4-0009GXPI-DO16GXPI-DO8GXPI-DO8-0100MK5 MZ5-10MMK5 MZ5-2MMK5 MZ5-5MMK5-10MMK5211-0/11MK5211-0/13.5MK5-2MMK5-5MMLK5 MLZ5-10MMLK5 MLZ5-2MMLK5 MLZ5-5MMLK5-10MMLK5-2MMLK5-5MMLZ5-10MMLZ5-2MMLZ5-5MMNK5 MNZ5-10MMNK5 MNZ5-2MMNK5 MNZ5-5MMNK5-10MMNK5-2MMNK5-5MMNK5-TRMNLK5 MNLZ5-10MMNLK5 MNLZ5-2MMNLK5 MNLZ5-5MMNLK5-10MMNLK5-2MMNLK5-5MMNLZ5-10MMNLZ5-2MMNLZ5-5MMNZ5-10MMNZ5-2MMNZ5-2MNK5MNZ5-5MMNZ5-ENK5-MNK5MNZ5-TRMZ5-10MMZ5211-0/11MZ5211-0/13.5MZ5-2MMZ5-2MK5MZ5-5MRJ45/HMRJ45S-10M/F211RJ45S-10M/F230RJ45S-10M/F41RJ45S-2M/F211RJ45S-2M/F230RJ45S-2M/F41RJ45S-5M/F211RJ45S-5M/F230RJ45S-5M/F41SRJ45S-10M/F21SRJ45S-2M/F21
102500921025009010250091102501021025010010250101102503881025037910250052102503861025037710250050102503871025037810250051
027027027027027027031029026031029026031029026
SRJ45S-10M/F21SRJ45S-2M/F21SRJ45S-5M/F21TRJ45-10M/F21TRJ45-2M/F21TRJ45-5M/F21TRJ45S-10M/F211TRJ45S-10M/F230TRJ45S-10M/F41TRJ45S-2M/F211TRJ45S-2M/F230TRJ45S-2M/F41TRJ45S-5M/F211TRJ45S-5M/F230TRJ45S-5M/F41
![Page 47: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but](https://reader036.fdocuments.net/reader036/viewer/2022081402/5f10a0b37e708231d44a0a09/html5/thumbnails/47.jpg)