Company Profile

Tianjin Geneuo Technology Co., Ltd. specializes in the development, production and sales of industrial

automation products, system integration and engineering service.

Communication solution

-Industry EtherNET Switch

-Fieldbus modules: ProfiNET, EtherNET/IP, EtherCAT, MODBUS TCP/IP I/O modules

Inductive sensors

-Different housing design are available:M5 to M80 and cubic

Optimized connection technology for efficient automation

-M5 to M40 receptacle, pre-moulding cable, field wireable connectivity

-Passive junction box and splitters

-Industrial network connectors for ProfiNET, EtherNET/IP, EtherCAT, MODBUS TCP/IP,Profibus,DeviceN-

ET,CC-link.

LED lighting

- Machine station lighting

- Factory lighting

- Intelligent lighting solutions

Geneuo exceptionally large product portfolio does not only cover all relevant standard solutions but also the

special requirements of individual industries. The products and the total solution have been widely used in

automotive, iron & steel, machine tool, elevator, textile, packaging, rubber machine etc.

Page 3: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

ContentsDigital I/O field bus modules

10

14

16

GX_DI8 Compact modules

GX_DO8 Compact modules

17

18

GX_DO16 Compact modules

GX_DI8DO8 Compact modules

Accessories

36Connectors(Power Supply)

Index

Index

42

Analog combined field bus modules

19GX_DI8AI4 combined modules

22GX_DI8AI4-0030 combined modules

21GX_DI8AI4-0020 combined modules

GX_DI16 Compact modules

20GX_DI8AI4-0010 combined modules

23GX_DI8AI4-0090 combined modules

26Connectors(Ethernet)

37

39

Connectors(I/O)

Field wirable connectors

33Connectors(PROFIBUS-DP)

12

GX_DIO16 Configurable compact modules

24GX_DIO8AO4-0009 combined modules

34Connectors(DeviceNet)

Page 4: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

GX series compact modules system

02 GSEE TECH

Features

- Protection degree upto IP67- ensuresmost successful application on-site

Fully sealed design- gives excellentvibration resistance feature

Smart and compact housing- makes installation much more easier

-

-

Communication

- Support for multiple open bus protocol

IP67 connector design, safety and reliablility

High integration communicationkernel, high-speed & stability

-

-

Page 5: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

03 GSEE TECH

Signal

- Support various kinds of signals, such as: digital & analog signals

Various signal combination function, suitablefor complex signal transmission requirements

Configurable modules for Input/Output and 4...20 mA/0...10 V signals make application much more handily

-

-

Connection

- Perfect connectors product line ensuresvarious connection for modules

Pre-moulding - T type - Field wirable connectors

Various kinds of connectors, fully satify your different requirements

-

-

DI

DO

DIO

AI-I/U

AO-I/U

Page 6: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

GX series compact modules system

04 GSEE TECH

The power interface

- Each module include male and female 7/8’’ connectors (1 male 1 female)Each power supply interface including the system power supply and load power supplyPre-moulding/Field wireable connectors

-

-

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

B

D

A

C Station Fieldbus addressing

- No address switch with PROFINET

The I/O interface- Each module has 8 female M12 A-code I/O interface Each M12 interface provide power supply and signal channel Pre-moulding/Field wireable connectors

--

The Fieldbus interface- Ethernet modules, each module has two male D-code M12

connectors interface PROFIBUS-DP, each module has two B-code M12 connectors interface(1 male 1 female)Devicenet,each module has two A-code M12 connectors interface(1 male 1 female)Pre-moulding/Field wireable connectors

-

-

-

7

1

5

AI

4

8

3

DI

2

PI

1

GX 0010

Product series

4 Number of channels4:8:16:

4 channels8 channels16 channels

Communication protocolDP: DN: PI: EN: EI: EC:

2

Signal typesDI:DO:DIO:

3 Special codes0 0 0 0

(DI):0-PNP、1-NPN

(DO):0-0.5A、1-2A

(AI):0-I、1-U、2-PT、3-TC、9-U/I

(AO):0-I、1-U、9-U/I

7

GX series modules type codes

6

4

PROFIBUS-DP DeviceNET PROFINET MODBUS-TCP/IP EtherNET/IP EtherCAT

Digital inputDigital outputDI/DO configured

Signal typesDO:AI:AO:

5Digital outputAnalog inputAnalog output

6 Number of channels

GX series module accessories selection guide

* Other agreement dial the code can be found in the P6 - P8

4:8:16:

4 channels8 channels16 channels

11

4

4

3

3

2

2

Page 7: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

05 GSEE TECH

A:Power interface7/8” single-ended pre-cast plug-in(female)

(Used to connected to the module and power supply )

MK5-*M

7/8” double-end pre-cast plug-in

(Used for power supply connection between modules and modules)

MK5 MZ5-*M

-

B:I/O interfaceSingle signal module(DI8、DO8)

M12 3 pin A-code single-ended pre-cast plug-in(1 male)

(Used to connected to the terminal or the scene can be wiring connector)

EZ3-*M/P00

M12 3 pin A code double-end pre-cast plug-in

(Used for the I/O connected to the plug-in type sensor or actuator )

EK3 EZ3-*M/P00

Dual signal module(DI16、DO16、DIO16、DI8DO8)

M12 4 pin A-code single-ended pre-cast plug-in(1 male)

(Used to connected to the terminal or the scene can be wiring connector)

EZ4-*M/P00

M12 4 pin A code double-end pre-cast plug-in

(With the T type for I/O with plug-in sensor or actuator connection)

EK4 EZ4-*M/P00

-

-

D:Fieldbus interface

-

EthernetRJ45/M12 D- code male connectors(Module-Switch/PLC)SRJ45S EIZ4-*M/F**

M12 Pre-moulding D- code connectors(male)(Modules-modules)EIZ4 EIZ4-*M/F**PROFIBUS-DPM12 Pre-moulding Female B-code (Module-PLC/IP20 Slaves)EPK5-*MM12 Pre-moulding B-code(Modules-modules)EPK5 EPZ5-*MDeviceNetM12 Pre-moulding Female A-code(Module-PLC/IP20 Slaves)ENK5-*MM12 Pre-moulding B-code(Modules-modules)ENK5 ENZ5-*M

-

-

-

* Details, refer to P36,Field wirable connector, refer to P39

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

MK5-*M MK5 MZ5-*M

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

* Details, refer to P37,Field wirable connector, refer to P40

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

Single signal module

Dual signal module

-

-

-

EZ3-*M/P00

EK3 EZ3-*M/P00

EZ4-*M/P00

EK4 EZ4-*M/P00

EK3 EZ3-*M/P00

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

PWR

I0

I1

I2

I3 I 7

I 6

I 5

I 4

1

2

3

4 8

7

6

5

BUS

SRJ45S EIZ4-*M/F** EIZ4 EIZ4-*M/F**

EPK5-*M EPK5 EPZ5-*M

ENK5-*M ENK5 ENZ5-*M

-

-

* Details, refer to P26-P35

Page 8: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

06 GSEE TECH

Ethernet

Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.

1 2

534

Port2

1

2

5

3

4

EtherNet-IP PORT1/2

012345678

9 012345678

9

x10 x1

012345678

9

IP Address

0 - DHCP / BOOTP

1 ... 254 - IP Address Byte 4

255 - DHCP / BOOTP

x100

Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.

1 2

534

Port2

1

2

5

3

4

PROFINET PORT1/2 GreenRedGreenRedGreenFlashing greenFlashing RedOffQuickly flashinggreenSlowly flashing greenOff

PWR

MS

NS

LINK

LED-Based DiagnosisOKUL failureOKModule failureOKPLC in STOP stateIP address not setNo connection with PLCEthermet link established,communication presentEthermet link established,no communication presentNo link

GreenRedOffGreenGreen, flashingRedRed, flashingOffGreenGreen, flashingRedRed, flashingOffGreenGreen, flickeringYellowYellow, flickering

PWR

MS

NS

LINK

LED-Based DiagnosisOKUL failureNo power or no IP addressOnline, one or more connections established (CIP Class 1 or 3)Online, no connections establishedDuplicate IP address, FATAL errorOne or more connections timed out (CIP Class 1 or 3)No powerControlled by a Scanner in Run stateNot configured, or Scanner in Idle stateMajor fault (EXCEPTION-state, FATAL error etc.)Recoverable fault(s). Module is configured, but stored parameters differ from currently used parameters.No link, no activityLink (100 Mbit/s) establishedActivity (100 Mbit/s)Link (10 Mbit/s) establishedActivity (10 Mbit/s)

PWR

MS

LK1 LK2

NS

I0

I1

I2

I3

I4

I5

I6

I7

I14

I15

I12

I13

I10

I11

I 8

I 9

PWR

MS

LK1 LK2

NS

I0

I1

I2

I3

I4

I5

I6

I7

I14

I15

I12

I13

I10

I11

I 8

I 9

Page 9: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

07 GSEE TECH

Ethernet

Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.

1 2

534

Port2

1

2

5

3

4

EtherCAT PORT1/2

Address : 0...999

012345678

9 012345678

9

x10 x1

012345678

9

x100

Port1 1.TD+2.RD+3.TD-4.RD-5.n.c.

1 2

534

Port2

1

2

5

3

4

Modbus PORT1/2

012345678

9 012345678

9

x10 x1

012345678

9

IP Address

x100

PWR

MS

NS

LINK

LED-Based Diagnosis

GreenRedOffGreenGreen, flashingRedRed, flashingOffGreenRedRed, flashingAlternating Red/greenOffGreenGreen, flickeringYellowYellow, flickering

PWR

MS

NS

LINK

LED-Based DiagnosisOKUL failureNo IP address or Exception stateAt least one Modbus message receivedWaiting for first Modbus messageIP address conflict detected, FATAL ERRORConnection timeout. No powerNormal operationMajor fault, FATAL ERRORMinor faultFirmware update from file system in progressNo link, no activityLink (100 Mbit/s) establishedActivity (100 Mbit/s)Link (10 Mbit/s) establishedActivity (10 Mbit/s)

GreenRedOffGreenGreen, blinkingGreen, single flashFlickeringRedOffRed, blinkingRed, single flashRed, double flashRedOffFlickeringFlashing greenGreen

OKUL failureINIT (or no power)OPERATIONALPRE-OPERATIONALSAFE-OPERATIONALBOOT(Fatal Event)No errorInvalid configurationUnsolicited state changeApplication watchdog timeoutApplication controller failureNo linkBooting error detectedLink sensed, traffic detectedLink sensed, no traffic detected

MODBUS TCP/IP

MS

LK1 LK2

NS

I0

I1

I2

I3

I4

I5

I6

I7

I14

I15

I12

I13

I10

I11

I 8

I 9

PWR

MS

LK1 LK2

NS

I0

I1

I2

I3

I4

I5

I6

I7

I14

I15

I12

I13

I10

I11

I 8

I 9

Page 10: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

08 GSEE TECH

PROFIBUS-DP/DeviceNet

1.Drain2.+V3.-V4.CAN_HIGH5.CAN_LOW

1

2

5

3

41

2

5

3

4

DeviceNet

0 ... 63

012345678

9 012345678

9

x10 x1

012345678

9

DR NA NA Address NA

0 ... 2Baud rateDR

DR

Kbit/s

DR 0 1 2

250125 500Address

1-No used2-Bus-A3-No used4-Bus-B5-Shield

15

42

3

1

5

4 2

3

Bus in(male) Bus out(female)

PROFIBUS-DP

0 ... 99012345678

9 012345678

9

x 10 x 1

ADDRESSAddress

GreenOffOffRedGreenRed

PWR

ERR

BUS

LED-Based DiagnosisOKUS failureOKUL failureOKPLC in STOP state

GreenRedOffGreenGreen, flashingRedRed, flashingAlternating Red/GreenOffGreenGreen, flashing

RedRed, flashingAlternating Red/Green

PWR

MS

NS

LED-Based DiagnosisOKUL failureNot online / No network powerOn-line, one or more connections are establishedOnline, no connections establishedCritical link failure, fatal evenOne or more connections timed-outExecuting self testNot operatingOperating in normal conditionMissing, incorrect or incomplete configuration, device needs commissioning.Unrecoverable Fault(s)Recoverable Fault(s)Executing self tes

PWR

MSNS

I0

I1

I2

I3

I4

I5

I6

I7

I14

I15

I12

I13

I10

I11

I 8

I 9

PWR

ERRBUS

I0

I1

I2

I3

I4

I5

I6

I7

I14

I15

I12

I13

I10

I11

I 8

I 9

Bus in(male) Bus out(female)

Page 11: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

09GSEE TECH

Page 12: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

10 GSEE TECH

GX_DI8 compact modules

Ordering data

GXDP-DI8 GXDN-DI8

GXPI-DI8 GXEC-DI8 GXEI-DI8 GXEN-DI8

Technical specifications

7/8”; 5-pole; U B max. 9 A, U L max. 9 A24 V DC (18…30.2 V), acc. to EN61131-2< 120 mA

M12, A-coded8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Input M12 x 1

Byte

0

bit0

C1P4

bit1

C2P4

bit2

C3P4

bit4

C5P4

bit3

C4P4

bit5

C6P4

bit7

C8P4

bit6

C7P4

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

8 channel Digital input(PNP)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

One channel per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

Digital input

MODBUS TCP/IP

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

PW

R

I0 I1 I2 I3I7I6I5I4

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

EE

* DeviceNet module Power supply 7/8” 4pins

Page 13: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

11 GSEE TECH

GX_DI8-1000 compact modules

Ordering data

GXDP-DI8-1000

GXPI-DI8-1000 GXEC-DI8-1000 GXEI-DI8-1000 GXEN-DI8-1000

Technical specifications

7/8”; 5-pole; UB max. 9 A, UL max. 9 A24 V DC (18…30.2 V), acc. to EN61131-2< 120 mA

M12, A-coded8(for 3-wire sensors or mech. switches,npn)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Input M12 x 1

Byte

0

bit0

C1P4

bit1

C2P4

bit2

C3P4

bit4

C5P4

bit3

C4P4

bit5

C6P4

bit7

C8P4

bit6

C7P4

Digital input

MODBUS TCP/IP

PW

R

I0 I 1 I2 I3I7I6I5I4

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

8 channel Digital input(NPN)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

One channel per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Page 14: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

12 GSEE TECH

GX_DI16 compact modules

Ordering data

GXDP-DI16 GXDN-DI16

PW

R

I0 I8 I1 I9 I2 I 10

I3 I11

I7 I15I6 I14I5 I13I4 I12226

62

6.3

24

39.7

213

GXPI-DI16 GXEC-DI16 GXEI-DI16 GXEN-DI16

Technical specifications

7/8"; 5-pole; U B max. 9 A, UL max. 9 A24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded16(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Input M12 x 1

Byte

0

1

bit0

C1P4

C1P2

bit1

C2P4

C2P2

bit2

C3P4

C3P2

bit4

C5P4

C5P2

bit3

C4P4

C4P2

bit5

C6P4

C6P2

bit7

C8P4

C8P2

bit6

C7P4

C7P2

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Digital input

MODBUS TCP/IP

1 2 3 48765

BU

S

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

16 channel Digital input(PNP)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

Two channels per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

EE

* DeviceNet module Power supply 7/8” 4pins

Page 15: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

13 GSEE TECH

GX_DI16-1000 compact modules

Ordering data

GXDP-DI16-1000

GXPI-DI16-1000 GXEC-DI16-1000 GXEI-DI16-1000 GXEN-DI16-1000

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded16(for 3-wire sensors or mech. switches,npn)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Input M12 x 1

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

MODBUS TCP/IP

PW

R

I0 I8 I1 I9 I2 I 10

I3 I11

I7 I15I6 I14I5 I13I4 I12

226

62

6.3

24

39.7

2131 2 3 4

8765

BU

S

Byte

0

1

bit0

C1P4

C1P2

bit1

C2P4

C2P2

bit2

C3P4

C3P2

bit4

C5P4

C5P2

bit3

C4P4

C4P2

bit5

C6P4

C6P2

bit7

C8P4

C8P2

bit6

C7P4

C7P2

Digital input

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

16 channel Digital input(NPN)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

Two channels per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 16: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

14 GSEE TECH

GX_DO8 compact modules

Ordering data

GXDP-DO8 GXDN-DO8

GXPI-DO8 GXEC-DO8 GXEI-DO8 GXEN-DO8

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded8(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Output M12 x 1

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Byte

0

bit0

C1P4

bit1

C2P4

bit2

C3P4

bit4

C5P4

bit3

C4P4

bit5

C6P4

bit7

C8P4

bit6

C7P4

Digital output

MODBUS TCP/IP

PW

R

O0

O7

O6

O5

226

62

6.3

24

39.7

2131 2 3 4

8765

BU

S

O1

O2

O3

O4

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

8 channel Digital output(0.5A)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

One channel per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

EE

* DeviceNet module Power supply 7/8” 4pins

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 17: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

15 GSEE TECH

GX_DO8-0100 compact modules

Ordering data

GXDP-DO8-0100

GXPI-DO8-0100 GXEC-DO8-0100 GXEI-DO8-0100 GXEN-DO8-0100

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded8(DC actuators)18…30 VDC 2 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz2A/Ch.(Amax=4*2A)galvanic isolation against the bus

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Output M12 x 1

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

MODBUS TCP/IP

PW

R

O0

O7

O6

O5

226

62

6.3

24

39.7

2131 2 3 4

8765

BU

S

O1

O2

O3

O4

Byte

0

bit0

C1P4

bit1

C2P4

bit2

C3P4

bit4

C5P4

bit3

C4P4

bit5

C6P4

bit7

C8P4

bit6

C7P4

Digital output

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

8 channel Digital output(2A)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

One channel per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 18: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

16 GSEE TECH

GX_DO16 compact modules

Ordering data

GXDP-DO16 GXDN-DO16

GXPI-DO16 GXEC-DO16 GXEI-DO16 GXEN-DO16

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded16(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Output M12 x 1

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Digital output

MODBUS TCP/IP

PW

R

O0 O8

O1 O9

O2

O 10

O3

O11

O7 O15

O6 O14

O5 O13

O4 O12

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

Byte

0

1

bit0

C1P4

C1P2

bit1

C2P4

C2P2

bit2

C3P4

C3P2

bit4

C5P4

C5P2

bit3

C4P4

C4P2

bit5

C6P4

C6P2

bit7

C8P4

C8P2

bit6

C7P4

C7P2

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

16 channel Digital output(0.5A)

System power supply and load power

supply independently

short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

Two channels per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

EE

* DeviceNet module Power supply 7/8” 4pins

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 19: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

17 GSEE TECH

GX_DI8DO8 compact modules

Ordering data

GXDP-DI8DO8 GXDN-DI8DO8

GXPI-DI8DO8 GXEC-DI8DO8 GXEI-DI8DO8 GXEN-DI8DO8

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded

8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

8(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionInputNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentOutputNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Input M12 x 1

Byte

DI0

DO0

bit0

C1P4

C5P4

bit1

C1P2

C5P2

bit2

C2P4

C6P4

bit4

C3P4

C7P4

bit3

C2P2

C6P2

bit5

C3P2

C7P2

bit7

C4P2

C8P2

bit6

C4P4

C8P4

Output M12 x 1

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Digital input/output

MODBUS TCP/IP

PW

R

I0 I1 I2 I3 I4 I 5 I6 I7

O6 O7O4 O5O2 O3O0 O1

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

8 channel Digital input(PNP)

8 channel Digital output(0.5A)

System power supply and load power

supply independently

Short circuit、overload、Reverse

polarity protection

Channel-related diagnostics

Two channels per connector

Fibre-glass reinforced PA6 housing

Vibration and shock-resistant

Encapsulated module electronics

Metal connector

Degree of protection IP67

EE

* DeviceNet module Power supply 7/8” 4pins

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 20: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

18 GSEE TECH

GX_DIO16 Configurable compact modules

Ordering data

GXDP-DIO16

GXPI-DIO16 GXEC-DIO16 GXEI-DIO16 GXEN-DIO16

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 180 mA

M12, A-coded

16(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

16(DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionInputNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentOutputNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolationBasic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Input M12 x 1

Byte

0

1

bit0

C1P4

C1P2

bit1

C2P4

C2P2

bit2

C3P4

C3P2

bit4

C5P4

C5P2

bit3

C4P4

C4P2

bit5

C6P4

C6P2

bit7

C8P4

C8P2

bit6

C7P4

C7P2

Digital output

Digital input

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Output M12 x 1

MODBUS TCP/IP

PW

R

IO0

IO8

IO1

IO9

IO2

IO10

IO3

IO11

IO7

IO15

IO6

IO14

IO5

IO13

IO4

IO12

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

Byte

0

1

bit0

C1P4

C1P2

bit1

C2P4

C2P2

bit2

C3P4

C3P2

bit4

C5P4

C5P2

bit3

C4P4

C4P2

bit5

C6P4

C6P2

bit7

C8P4

C8P2

bit6

C7P4

C7P2

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

16 configurable digital channelsInput/output adaptivePNP inputs / outputs 0.5 A System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connectorFibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 21: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

19 GSEE TECH

GX-DI8AI4 combined modules

Ordering data

GXDP-DI8AI4

GXPI-DI8AI4 GXEC-DI8AI4 GXEI-DI8AI4

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded

8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

4approx. 100Ohm, difference input<200 mA/port0 / 4...20mA12bit (0-4095)/ 16bit(0-32767)approx. 10ms per channel24VDC(18…30.2V)

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput resistanceSensor supplyMeasuring rangesResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Digital input M12 x 1

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Analog input M12 x 1

Pin 1 +24VPin 2 A +Pin 3 0VPin 4 A -3

2

5

1

4

2

1

4

34

1

32

2

4

1

3

Digital input

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

PW

R

I0 I1 I2 I3 I4 I5 I6 I7

A3A2A1A0

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

Add..

Ch.

Byte0

C5(A0)

Byte1 Byte2

C6(A1)

Byte4

C7(A2)

Byte3 Byte5 Byte7Byte6

C8(A3)

Analog input

* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.

8 channel Digital input(PNP)4 channel analog current inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 22: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

20 GSEE TECH

GX_DI8AI4-0010 combined modules

Ordering data

GXDP-DI8AI4-0010

GXPI-DI8AI4-0010 GXEC-DI8AI4-0010 GXEI-DI8AI4-0010

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded

8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

4< 100 kΩ<120 mA/port-10/0 ... +10 VDC12bit (0-4095)/ 16bit(0-32767)approx. 5ms per channel24VDC(18…30.2V)

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput resistanceSensor supplyMeasuring rangesResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

M12 Digital input

M12 Analog input

Pin 1 +24VPin 2 V +Pin 3 0VPin 4 V -3

2

5

1

4

2

1

4

34

1

32

2

4

1

3

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

PW

R

I0 I1 I2 I3 I4 I5 I6 I7

A3A2A1A0226

62

6.3

24

39.7

2131 2 3 4

8765

BU

S

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Digital input

* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

Add..

Ch.

Byte0

C5(A0)

Byte1 Byte2

C6(A1)

Byte4

C7(A2)

Byte3 Byte5 Byte7Byte6

C8(A3)

Analog input

* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.

8 channel Digital input(PNP)4 channel analog Voltage inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnostics Two channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 23: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

21 GSEE TECH

GX_DI8AI4-0020 combined modules

Ordering data

GXDP-DI8AI4-0020

GXPI-DI8AI4-0020 GXEC-DI8AI4-0020 GXEI-DI8AI4-0020

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded

8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

4Pt100, Pt200, Pt500, Pt1000, Ni100, Ni10000...100Ω, 0...200Ω, 0...400Ω, 0...1000Ω< 0.2 %0.05 %< 300 ppm/°C of full scale16Bit16 bit signed integerapprox. 20ms per channel

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput type

Basic fault limit at 23 °CRepeatabilityTemperature coeffi cientResolutionMeasured-value displayCycle time Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Digital input M12 x 1

Analog input M12 x 1

3

2

5

1

4

Pin 1 redPin 2 redPin 3 whitePin 4 whitePin 5 n.c.

2

1

4

3

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

PW

R

I0 I1 I2 I3 I4 I 5 I6 I7

A3A2A1A0

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Digital input

* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

Add..

Ch.

Byte0

C5(A0)

Byte1 Byte2

C6(A1)

Byte4

C7(A2)

Byte3 Byte5 Byte7Byte6

C8(A3)

Analog input

* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.

8 channel Digital input(PNP)4 channel analog RTD inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 24: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

22 GSEE TECH

GX_DI8AI4-0030 combined modules

Ordering data

GXDP-DI8AI4-0030

GXPI-DI8AI4-0030 GXEC-DI8AI4-0030 GXEI-DI8AI4-0030

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded

8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

4types E / S / J / T / K / B / N / C / R / L< 0.2 %0.05 %<300 ppm/°C16bit16 bit signed integerapprox. 20ms per channel

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog inputNumber of channelsInput typeBasic fault limit at 23 °CRepeatabilityTemperature coeffi cientResolutionMeasured-value displayConversion time Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Digital input M12 x 1

Analog input M12 x 1

3

2

5

1

4

Pin 1 PT1000Pin 2Pin 3 PT1000Pin 4 TH-Pin 5 n.c.

1

32

4

TH+

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

PW

R

I0 I1 I2 I 3 I4 I5 I6 I7

A3A2A1A0

226

62

6.3

24

39.7

2131 2 3 4

8765

BU

S

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Digital input

* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

Add..

Ch.

Byte0

C5(A0)

Byte1 Byte2

C6(A1)

Byte4

C7(A2)

Byte3 Byte5 Byte7Byte6

C8(A3)

Analog input

* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.

8 channel Digital input(PNP)4 channel analog TC inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 25: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

23 GSEE TECH

GX_DI8AI4-0090 combined modules

Ordering data

GXDP-DI8AI4-0090

GXPI-DI8AI4-0090 GXEC-DI8AI4-0090 GXEI-DI8AI4-0090

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 150 mA

M12, A-coded

8(for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

4approx. 100Ohm, difference input<200 mA/port0 / 4...20mA(I) 、-10/0 ... +10 VDC(U)12bit (0-4095)/ 16bit(0-32767)approx. 10ms per channel24VDC(18…30.2V)

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 according to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionDigital inputNumber of channelsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentAnalog input(I/U)Number of channelsInput resistanceSensor supplyMeasuring rangesResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

Power supply 7/8”

Digital input M12 x 1

Analog input M12 x 1

Pin 1 +24VPin 2 V +Pin 3 0VPin 4 V -3

2

5

1

4

2

1

4

34

1

32

2

4

1

3

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Digital input

* "C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

Add..

Ch.

Byte0

C5(A0)

Byte1 Byte2

C6(A1)

Byte4

C7(A2)

Byte3 Byte5 Byte7Byte6

C8(A3)

Analog input

* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.

PW

R

I0 I1 I2 I3 I4 I5 I6 I7

A3A2A1A0226

62

6.3

24

39.7

2131 2 3 4

8765

BU

S

8 channel Digital input(PNP)4 channel analog current/Voltage inputs System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connector(DI)Fibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 26: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

GX_DIO8AO4-0009 combined modules

Technical specifications

24 V DC (18…30.2 V), acc. to EN61131-2< 180 mA

M12, A-coded

8 (for 3-wire sensors or mech. switches,pnp)18…30 VDC 24 V DC (18…30, 2V), <= 150 mA/port2 mA/4 mA2.5 ms≤ 250 Hz100 mA

8 (DC actuators)18…30 VDC 0.5 A, short-circuit proofresistive, inductive, lamp load1≤ 250 Hz0.7A/Ch.(Amax=8*0.7A)galvanic isolation against the bus

Supply voltageConnectionSupply voltageOperating current I/O-ports ConnectionInputNumber of inputsInput voltageSensor supplySwitching thresholdInput delaySwitching frequencyMax. input currentOutputNumber of outputsOutput voltageOutput current per channelLoad typeSimultaneity factorSwitching frequencyMax. output currentElectrical isolation

Input M12 x 1

Output M12 x 1

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Digital input

Byte

0

bit0

C1P4

bit1

C1P2

bit2

C2P4

bit4

C3P4

bit3

C2P2

bit5

C3P2

bit7

C4P2

bit6

C4P4

Digital output

24 GSEE TECH

PW

R

A 3A 2A 1A 0

226

62

6.3

24

39.7

213

1 2 3 48765

BU

S

IO0

IO1

IO2

IO3

IO4

IO5

IO6

IO7

"C1P4" represents the 4th pin of the 1st M12 interface in the I/O interface.

8 configurable digital channels4 channel analog current/Voltage outputsPNP inputs / outputs 0.5 A System power supply and load power supply independentlyShort circuit、overload、Reverse polarity protectionChannel-related diagnosticsTwo channels per connectorFibre-glass reinforced PA6 housingVibration and shock-resistantEncapsulated module electronicsMetal connectorDegree of protection IP67

7/8"; 5-pole; U B max. 9 A, UL max. 9 A

Page 27: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

Ordering data

GXDP-DIO8AO4-0009

GXPI-DIO8AO4-0009 GXEC-DIO8AO4-0009 GXEI-DIO8AO4-0009

4≥ 500Ohm(I) / ≥ 1 kΩ(U)0 / 4...20mA(I) 、-10/0 ... +10 VDC(U)12Bit(0-4095)/16Bit(0-32767)approx. 10ms per channel24VDC(18…30.2V)

226x62x24mm515gGlass fiber enhanced nylon(PA6)2*∅6.3 mm-25…+70 °C-30 ~+85 °Caccording to EN 60068-2-6according to EN 60068-2-27according to EN 61000-6-2, 6-4IP67CE

Analog input(I/U)Number of channelsResistanceOutput typeResolution/Data(DEC)Conversion timeSensor power supply Basic dataDimensions (H x W x D)WeightHousing materialInstallationOperating temperatureStorage temperatureVibration testedShock testedEMCDegree of protection Approvals

* Ethernet communication interface refer to P6,PROFIBUS-DP/Device Netcommunication interface refer to P8.

Analog output M12 x 1

Pin 1 +24VPin 2 A +Pin 3 0VPin 4 A -3

2

5

1

4

25 GSEE TECH

GX_DIO8AO4-0009 combined modules

Power supply 7/8”

Add..

Ch.

Byte0

C5(A0)

Byte1 Byte2

C6(A1)

Byte4

C7(A2)

Byte3 Byte5 Byte7Byte6

C8(A3)

Analog output

* "C5 (A0)" means that the 5 M12 interface in the I/O interface is AI0.

Page 28: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

26 GSEE TECH

Connector(Ethernet/IPTM.ModbusTMTCP) Type NO. ID NO. Pinout

M12 Pre-mouldingRight angleMale

M12 Pre-mouldingRight angleFemale

M12 Pre-mouldingStraightMale

M12 Pre-mouldingStraightFemale

Standard1.WH/OR2.OR3.WH/GN4.N/C5.N/C6.GN7.N/C8.N/CCross1.WH/GN2.GN3.WH/OR4.N/C5.OR6.N/C7.N/C8.N/C

M12 ReceptacleFemale

M12 ReceptacleMale

RJ45 straight

RJ45 right angle Buckle up

RJ45 right angle Buckle down

45678312

EIK4-2M/F41EIK4-5M/F41EIK4-10M/F41

100172101001721110017212

100172151001721610017217

100172201001722110017222

100172251001722610017227

100173951001739610017397

100174001001740110017402

102500401025004110250042

102500501025005110250052

102500601025006110250062

EIZ4-2M/F41EIZ4-5M/F41EIZ4-10M/F41

EILK4-2M/F41EILK4-5M/F41EILK4-10M/F41

EILZ4-2M/F41EILZ4-5M/F41EILZ4-10M/F41

FEIK41-2M/F41FEIK41-5M/F41FEIK41-10M/F41

FEIZ41-2M/F41FEIZ41-5M/F41FEIZ41-10M/F41

RJ45S-2M/F41RJ45S-5M/F41RJ45S-10M/F41

TRJ45S-2M/F41TRJ45S-5M/F41TRJ45S-10M/F41

BRJ45S-2M/F41BRJ45S-5M/F41BRJ45S-10M/F41

Male

Female

1.WH/OR(+tx)2.WH/GN(+rx)3.OR(-tx)4.GN(-rx)

1

4

3

2

4

31

2

*Cross type:RJ45S-*M/F41-CRTRJ45S-*M/F41-CRBRJ45S-*M/F41-CR

Ø15

M12

x148.1

13

Ø15

M12

x1

55.821

Ø15M12x1

32

46

46

39.2

Ø15M12x1

18

M12×1

PG9

21.5

25

M12×1

PG9

20

53.5

41

34

41

34

Accessories

Page 29: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

27 GSEE TECH

Connector(PROFINET) Type NO. ID NO. Pinout

M12 Pre-mouldingRight angleMale

M12 Pre-mouldingRight angleFemale

M12 Pre-mouldingStraightMale

M12 Pre-mouldingStraightFemale

M12 ReceptacleFemale

M12 ReceptacleMale

RJ45 right angle Buckle up

RJ45 right angle Buckle down

EIK4-2M/F21EIK4-5M/F21EIK4-10M/F21

100173201001732110017322

100173251001732610017327

100173301001733110017332

100173351001733610017337

100174151001741610017417

100174201001742110017422

102500901025009110250092

102501001025010110250102

102501101025011110250112

EIZ4-2M/F21EIZ4-5M/F21EIZ4-10M/F21

EILK4-2M/F21EILK4-5M/F21EILK4-10M/F21

EILZ4-2M/F21EILZ4-5M/F21EILZ4-10M/F21

FEIK41-2M/F21FEIK41-5M/F21FEIK41-10M/F21

FEIZ41-2M/F21FEIZ41-5M/F21FEIZ41-10M/F21

SRJ45S-2M/F21SRJ45S-5M/F21SRJ45S-10M/F21

TRJ45-2M/F21TRJ45-5M/F21TRJ45-10M/F21

BRJ45-2M/F21BRJ45-5M/F21BRJ45-10M/F21

孔座

针座

1.Yellow(+tx)2.White(+rx)3.Orange(-tx)4.Blue(-rx)

1.YE2.OR3.WH4.N/C5.N/C6.BU7.N/C8.N/C

45678312

4

1

2

4

3

2

RJ45 straight Quick Unlock

Ø15

M12

x148.1

13

Ø15

M12

x1

55.821

Ø15M12x1

32

46

46

39.2

Ø15M12x1

18

M12×1

PG9

21.5

25

M12×1

PG9

20

41

34

41

34

49.8

3

1

Accessories

Page 30: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

28 GSEE TECH

Pinout

M12预铸直线孔座

Connector(EtherCAT) Type NO. ID NO.

1

4

3

2

4

31

2

M12 Pre-mouldingRight angleMale

M12 Pre-mouldingRight angleFemale

M12 Pre-mouldingStraightMale

M12 Pre-mouldingStraightFemale Female

Male

M12 ReceptacleFemale

M12 ReceptacleMale

18

M12×1

PG9

21.5

Ø15

M12

x1

55.821

Ø15

M12

x1

48.113

Ø15M12x1

32

46

46

39.2

Ø15M12x1

25

M12×1

PG9

20

1.Orange/White (+tx)2.Blue/White(+rx)3.Orange(-tx)4.Blue(-rx)

EIK4-2M/F230EIK4-5M/F230EIK4-10M/F230

100162651001626610016267

100162681001626910016270

EIZ4-2M/F230EIZ4-5M/F230EIZ4-10M/F230

100162711001628410016273

100162741001627510016276

100410571004105810041059

100410601004103710041038

EILK4-2M/F230EILK4-5M/F230EILK4-10M/F230

EILZ4-2M/F230EILZ4-5M/F230EILZ4-10M/F230

FEIK41-2M/F230FEIK41-5M/F230FEIK41-10M/F230

FEIZ41-2M/F230FEIZ41-5M/F230FEIZ41-10M/F230

Ø4.8

Ø4.8

Ø4.8

Ø4.8

Ø4.8

Ø4.8

Accessories

Page 31: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

29 GSEE TECH

Connector(EtherCAT) Type NO. ID NO. Pinout

RJ45 straight

RJ45 right angle Buckle up

RJ45 right angle Buckle down

45678312

53.5

41

34

41

34

102503741025037510250376

RJ45S-2M/F230RJ45S-5M/F230RJ45S-10M/F230

102503771025037810250379

102503801025038110250382

TRJ45S-2M/F230TRJ45S-5M/F230TRJ45S-10M/F230

BRJ45S-2M/F230BRJ45S-5M/F230BRJ45S-10M/F230

1.OR/WH2.OR3.BU/WH4.N/C5.N/C6.BU7.N/C8.N/C

Ø4.8

Ø4.8

Ø4.8

BuleWhite/BuleOrangeWhite/Orangee

JacketBraid

Foil

Insulation

F230

Suffix code

F23080°C 30Volts

Cable Type NO. Authentication

CS042671-*M

Data parameter JacketCable

parameters20 °C Conductor

resistance/insulatiMaterial、Colour

、Outer diameter

Shield

Foil/BraidUL/CSADESINA CE

4*26AWG

140 PO

PUR Yellow green4.8mm

Ω/km

Accessories

Page 32: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

30 GSEE TECH

Pinout

M12预铸直线孔座

Connector(EtherCAT) Type NO. ID NO.

1

4

3

2

4

31

2

M12 Pre-mouldingRight angleMale

M12 Pre-mouldingRight angleFemale

M12 Pre-mouldingStraightMale

M12 Pre-mouldingStraightFemale Female

Male

M12 ReceptacleFemale

M12 ReceptacleMale

18

M12×1

PG9

21.5

Ø15

M12

x1

55.821

Ø15

M12

x1

48.113

Ø15M12x1

32

46

46

39.2

Ø15M12x1

25

M12×1

PG9

20

Ø5.2

Ø5.2

Ø5.2

Ø5.2

Ø5.2

Ø5.2

1.Yellow(+tx)2.White(+rx)3.Orange(-tx)4.Blue(-rx)

EIK4-2M/F211EIK4-5M/F211EIK4-10M/F211

100162771001627810016279

100162801001628110016282

EIZ4-2M/F211EIZ4-5M/F211EIZ4-10M/F211

100162831001628410016285

100162861001628710016288

100410451004104610041047

100410481004104910041050

EILK4-2M/F211EILK4-5M/F211EILK4-10M/F211

EILZ4-2M/F211EILZ4-5M/F211EILZ4-10M/F211

FEIK41-2M/F211FEIK41-5M/F211FEIK41-10M/F211

FEIZ41-2M/F211FEIZ41-5M/F211FEIZ41-10M/F211

Accessories

Page 33: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

31 GSEE TECH

Connector(EtherCAT) Type NO. ID NO. Pinout

RJ45 straight

RJ45 right angle Buckle up

RJ45 right angle Buckle down

45678312

53.5

41

34

41

34

102503831025038410250385

RJ45S-2M/F211RJ45S-5M/F211RJ45S-10M/F211

102503861025038710250388

102503891025039010250391

TRJ45S-2M/F211TRJ45S-5M/F211TRJ45S-10M/F211

BRJ45S-2M/F211BRJ45S-5M/F211BRJ45S-10M/F211

1.YE2.OR3.WH4.N/C5.N/C6.BU7.N/C8.N/C

JacketBraid

Foil

Insulation

OrangeYellowBuleWhite

F211

Suffix code

F21180°C 300 Volts

Cable Type NO. Authentication

CS042461-*M

Data parameter JacketCable

parameters20 °CConductor

resistance/insulationMaterial、Colour

、Outer diameter

Shield

Foil/BraidUL/CSADESINA CE

4*24AWG 91 PO

PVC Yellow green 5.4mmΩ/km

Accessories

Page 34: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

32 GSEE TECH

Field wirable connector(Ethernet) Type NO. ID NO. Features Pinout

M12 Right angleMale

M12 Right angleFemale

M12 StraightMale

M12 StraightFemale

RJ45 StraightMetal Field wirable

12345678

AWG27-AWG22Cable parametersCable diameter:5.5-9 mm70°C, 125V, 1.5 A10/100Mbps

4A,250V,-40 ~ +85°CMatch with4-pin D-codeM12 pre-moulding/receptacle connector

EK4238-0/9

EZ4238-0/9

ELK4238-0/9

ELZ4238-0/9

RJ45/HM

Female

Male4

3

2

1

4

1

2

3

10091220

10091230

10091221

10091231

10250161

Accessories

Page 35: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

100120001001200110012002

100120101001201110012012

100120201001202110012022

100120301001203110012032

100120401001204110012042

100120701001207110012072

Connector(Profibus-DP) Features

M12 Pre-mouldingStraight FemaleB-code, Braid

Type NO.

EPK5-2MEPK5-5MEPK5-10M

ID NO.

1=n.c

2=GN(Bus A)

3=n.c

4=RD(Bus B)

5=n.c

1

2

3

45

Pinout

1=n.c

2=GN(Bus A)

3=n.c

4=RD(Bus B)

5=n.c

48.110.8

15

M12x1

32

15

46

38

M12x1

55.818

15

M12x1

4638

39.2

15M12x1

48.110.8

15

55.818

15

M12x1

M12x1

4638

39.2

15

32

15

4638

M12x1 M12x1

M12 Pre-mouldingRight angle FemaleB-code, Braid

M12 Pre-mouldingStraight MaleB-code, Braid

M12 Pre-mouldingRight angle MaleB-code, Braid

M12 Pre-mouldingFemale/MaleB-code, Braid

M12 Pre-mouldingFemale/MaleB-code, Braid

EPLK5-2MEPLK5-5MEPLK5-10M

EPZ5-2MEPZ5-5MEPZ5-10M

EPLZ5-2MEPLZ5-5MEPLZ5-10M

EPK5 EPZ5-2MEPK5 EPZ5-5MEPK5 EPZ5-10M

EPLK5 EPLZ5-2MEPLK5 EPLZ5-5MEPLK5 EPLZ5-10M

1

2

3

4 5

1

2

3

451=n.c

2=GN(Bus A)

3=n.c

4=RD(Bus B)

5=n.c1

2

3

4 5

58100251Profibus-DP CableTwo core Multi StrandFoil/Braid

CS022280-*M RD

VT

7.6

GN

10091200EK5228-0/9

1

2

3

4 5

1

2

3

4510091210EZ5228-0/9

M12x1

57.4 19.6

M12x1

2062

4A,250V,-40 ~ +85°CMatch with5-pin B-codeM12 pre-moulding/receptacle connectorFemale

4A,250V,-40 ~ +85°CMatch with5-pin B-codeM12 pre-moulding/receptacle connectorMale

10081001

10085000

Profibus-DP Splitter EPK5-2EPZ5-V

Profibus-DPTermination resistors

EPZ5-TR

234.58

25

M12x1

M12x1

3818

M12x1

M12x1

4322.1

14.216.4

12

3

45

2xM12 Male

3

1=5VDC2=Bus-A3=GND4=Bus-B5=Shield1

2

4 5

1xM12 Female

1

2

345

390

390

220

1/4W

1/4W

1/4W

1=5VDC2=Bus-A

3=GND4=Bus-B 5=Shield

1xM12 Male

33 GSEE TECH

Accessories

Page 36: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

100130001001300110013002

100130101001301110013012

100130201001302110013022

100130301001303110013032

100130401001304110013042

100130701001307110013072

Connector(Devicenet) Features

M12 Pre-mouldingStraight FemaleA-code, Thin Cable

Type NO.

ENK5-2MENK5-5MENK5-10M

ID NO.

1=Sheild

2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)

1=Sheild

2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)

1=Sheild

2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)

Pinout

M12 Pre-mouldingRight angle FemaleA-code, Thin Cable

M12 Pre-mouldingStraight MaleA-code, Thin Cable

M12 Pre-mouldingRight angle MaleA-code, Thin Cable

M12 Pre-mouldingFemale/MaleA-code, Thin Cable

M12 Pre-mouldingFemale/MaleA-code, Thin Cable

ENLK5-2MENLK5-5MENLK5-10M

ENZ5-2MENZ5-5MENZ5-10M

ENLZ5-2MENLZ5-5MENLZ5-10M

ENK5 ENZ5-2MENK5 ENZ5-5MENK5 ENZ5-10M

ENLK5 ENLZ5-2MENLK5 ENLZ5-5MENLK5 ENLZ5-10M

48.110.8

15

M12x1

32

15

4638

M12x1

55.818

15

M12x1

4638

39.2

15M12x1

55.818

15

M12x148.110.8

15

M12x1

4638

39.2

15M12x1

32

15

4638

M12x1

1

2

3

45

1

2

3

4 5

1

2

3

45

1

2

3

4 5

1008501010085011

Terminating resistorM12x1 MaleM12x1 Female

ENZ5-TRENK5-TR

28

17.5

31.5

7/8-16UN

7/8-16UNM12x1

7337.4

26

2

1x 7/8"Female

1

345

1=Shield2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)

1x 7/8"Male12

34

5

1xM12Female

1

2

3

45

M12Male

M12Female

1

2

3

4 5

1=Shield2=RD(V+)3=BK(V-)

4=WH(CAN H)5=BU(CAN L)

1201/4W

1201/4W

2

5

1

48.510.8

15

M12x1

M12x1

15

1855.8

DeviceNET T type MNZ5-ENK5-MNK5 10082001

34 GSEE TECH

Accessories

Page 37: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

100310001003100110031002

100310101003101110031012

100310201003102110031022

100310301003103110031032

100310401003104110031042

100310701003107110031072

582002515821025158220251

Connector(Devicenet) Features

7/8’’Pre-mouldingStraight FemaleThick Cable

Type NO.

MNK5-2MMNK5-5MMNK5-10M

ID NO. Pinout

7/8’’Pre-mouldingRight angle FemaleThick Cable

7/8’’Pre-mouldingStraight MaleThick Cable

7/8’’Pre-mouldingRight angle MaleThick Cable

7/8’’Pre-mouldingFemale/MaleThick Cable

7/8’’Pre-mouldingFemale/MaleThick Cable

MNLK5-2MMNLK5-5MMNLK5-10M

MNZ5-2MMNZ5-5MMNZ5-10M

MNLZ5-2MMNLZ5-5MMNLZ5-10M

MNK5 MNZ5-2MMNK5 MNZ5-5MMNK5 MNZ5-10M

MNLK5 MNLZ5-2MMNLK5 MNLZ5-5MMNLK5 MNLZ5-10M

CS041580-*MCS041680-*MCS042280-*M

Thick CableMid CableThin Cable

7/8-16UN20.5

17.5

11

65

29

27

7/8-16UN

51.25

4030.55

277/8-16UN

4111

17.5

51.25

43.534

277/8-16UN

4111

17.5

1

2

34

5

1

2

34

5

1=Shield

2=RD(V+)

3=BK(V-)

4=WH(CAN H)

5=BU(CAN L)

1=Shield

2=RD(V+)

3=BK(V-)

4=WH(CAN H)

5=BU(CAN L)

20.5

11 7/8-16UN

2717.5

68.536

7/8-16UN

27

68.536

27

7/8-16UN

65

29

51.25

40

30.55

27

7/8-16UN

41

51.25

43.534

277/8-16UN

41

1

23

4

5

1=Shield

2=RD(V+)

3=BK(V-)

4=WH(CAN H)

5=BU(CAN L)

1

23

4

5

BlueWhiteBlackRed Power

Data

10082000DeviceNET T type MNZ5-2MNK5

1008502010085021

Terminating resistor7/8” Male7/8” Female

MNZ5-TRMNK5-TR

28

17.5

34.8

7/8-16UN

7/8-16UN

37.473

7/8-16UN26

26

7/8-16UN48.5

26

36

7/8-16UN

26

32

44.5

7/8"Male

7/8"Female1

23

45

1=Shield2=RD(V+)3=BK(V-)

4=WH(CAN H)5=BU(CAN L)

1201/4W

1201/4W

1x7/8"Male

1

23

4

5

1

23

45

1=Shield2=RD(V+)3=BK(V-)4=WH(CAN H)5=BU(CAN L)

2x7/8"Female

35 GSEE TECH

Accessories

Page 38: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

100330001003300110033002

100330101003301110033012

100330201003302110033022

100330301003303110033032

100330401003304110033042

100330701003307110033072

Connector(Power Supply) Features

7/8’’Pre-mouldingStraight Female

Type NO.

MK5-2MMK5-5MMK5-10M

ID NO. Pinout

7/8’’Pre-mouldingRight angle Female

7/8’’Pre-mouldingStraight Male

7/8’’Pre-mouldingRight angle Male

7/8’’Pre-mouldingFemale/Male

7/8’’Pre-mouldingFemale/Male

MLK5-2MMLK5-5MMLK5-10M

MZ5-2MMZ5-5MMZ5-10M

MLZ5-2MMLZ5-5MMLZ5-10M

MK5 MZ5-2MMK5 MZ5-5MMK5 MZ5-10M

MLK5 MLZ5-2MMLK5 MLZ5-5MMLK5 MLZ5-10M

1

2

34

5

1

2

34

5

1

2

34

5

7/8-16UN15.5

26

2950.5

18

8.71=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)

1=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)

1=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)

51.25

4030.55

418.7

17.5

267/8-16UN

7/8-16UN

26

8.7

3654

15.5

51.25

43.534

418.7

17.5

267/8-16UN

34

5

2

1

1=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)

1=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)

34

5

2

1

34

5

2

1

1

2

34

51=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)3

4

5

2

1

7/8-16UN

26

8.7

3654

15.57/8-16UN15.5

26

2950.5

18

51.25

4030.55

41

267/8-16UN

51.25

43.534

418.7

267/8-16UN

28

17.5

34.8

7/8-16UN

7/8-16UN

7337.4

26

7/8-16UN26

100840007/8”T type power connector 5pins

MZ5-2MK5 2x7/8"Female

1x7/8"Male

1

2

34

51=BK (GND)

2=BU (GND)

3=GNYE (PE)

4=BN (US)

5=WH (UA)3

4

5

2

1

36 GSEE TECH

Accessories

Page 39: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

37 GSEE TECH

Accessories

Connector(I/O) Features Type NO. ID NO. Pinout

100110601001106110011062

100110701001107110011072

M12 Pre-mouldingStraight Female3pinsA-code

EZ3-2M/P00EZ3-5M/P00EZ3-10M/P00

M12 Pre-mouldingStraight Female4pinsA-code

EZ4-2M/P00EZ4-5M/P00EZ4-10M/P00

100110901001109110011092

M12 Pre-mouldingRight angle Female3pinsA-code

ELZ3-2M/P00ELZ3-5M/P00ELZ3-10M/P00

3 BU

4 BK

1 BN

5 GY

2 WH

3 BU

4 BK

1 BN

48.818

15

M12x1

35.528.6

32.7

15M12x1

3 BU

4 BK

1 BN

5 GY

2 WH

3 BU

4 BK

1 BN

2 WH

3 BU

4 BK

1 BN

2 WH

3 BU

4 BK

1 BN

100115101001151110011512

M12 Pre-mouldingStraight Female5pinsA-code

EZ5-2M/P00EZ5-5M/P00EZ5-10M/P00

100111001001110110011102

M12 Pre-mouldingRight angle Female4pinsA-code

ELZ4-2M/P00ELZ4-5M/P00ELZ4-10M/P00

100115301001153110011532

M12 Pre-mouldingRight angle Female5pinsA-code

ELZ5-2M/P00ELZ5-5M/P00ELZ5-10M/P00

Page 40: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

38 GSEE TECH

Accessories

Connector(I/O) Features Type NO. ID NO. Pinout

100111201001112110011122

100111301001113110011132

100115501001155110011552

M12 Pre-mouldingFemale/Male3pinsA-code

EK3 EZ3-2M/P00EK3 EZ3-5M/P00EK3 EZ3-10M/P00

M12 Pre-mouldingFemale/Male4pinsA-code

EK4 EZ4-2M/P00EK4 EZ4-5M/P00EK4 EZ4-10M/P00

100115401001154110011542

M12 Pre-mouldingFemale/Male5pinsA-code

EK5 EZ5-2M/P00EK5 EZ5-5M/P00EK5 EZ5-10M/P00

100111601001116110011162

M12 Pre-mouldingFemale/Male4pinsA-code

ELK4 ELZ4-2M/P00ELK4 ELZ4-5M/P00ELK4 ELZ4-10M/P00

M12 Pre-mouldingFemale/Male5pinsA-code

ELK5 ELZ5-2M/P00ELK5 ELZ5-5M/P00ELK5 ELZ5-10M/P00

2 WH*

3 BU

4 BK

1 BN

2 WH*

3 BU

4 BK

1 BN

2 WH

3 BU

4 BK

1 BN

5 GY

5 GY

2 WH

3 BU

4 BK

1 BN

40.710.8

15

M12x1

48.818

15

M12x1

2 WH*

3 BU

4 BK

1 BN

2 WH*

3 BU

4 BK

1 BN

2 WH

3 BU

4 BK

1 BN

5 GY

5 GY

2 WH

3 BU

4 BK

1 BN

35.528.6

32.7

15M12x1

M12x1

24.9

15

35.5

28.6

100111501001115110011152

M12 Pre-mouldingFemale/Male3pinsA-code

ELK3 ELZ3-2M/P00ELK3 ELZ3-5M/P00ELK3 ELZ3-10M/P00

Page 41: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

39 GSEE TECH

Accessories

Features Type NO. ID NO. Pinout

10092101

10092102

MK5211-0/11

Nylon+Glass fiber/BlackCast aluminum coupling nutsPG13.5 cable glandAccepts 10-12 mm cable diameterScrew terminals 85°C,250V,9 A

MK5211-0/13.5

10092121Nylon+Glass fiber/BlackCast aluminum coupling nutsPG11 cable glandAccepts 8-10 mm cable diameterScrew terminals 85°C,250V,9 A

MZ5211-0/11

5pins 7/8’’ Field wirable connector (power supply / DeviceNET )

Nylon+Glass fiber/BlackCast aluminum coupling nutsPG11 cable glandAccepts 8-10 mm cable diameterScrew terminals 85°C,250V,9 A

8527

7/8-16UN

8827

7/8-16UN

1

23

4

5

1

2

3

4

510092122Nylon+Glass fiber/Black

Cast aluminum coupling nutsPG11 cable glandAccepts 10-12 mm cable diameterScrew terminals 85°C,250V,9 A

MZ5211-0/13.5

Page 42: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

40 GSEE TECH

Accessories

10091020

10091021EZ4112-0/9

10091022EZ5112-0/7

10091023EZ5112-0/9

Field wireable connector Features Type NO.

EZ4112-0/7

ID NO. Pinout

1

2

3

45

61 19.6

M12x1

10091030

10091031ELZ4112-0/9

10091032ELZ5112-0/7

10091033ELZ5112-0/9

ELZ4112-0/7

1

2

3

4

1

2

3

45

41.9 19.6

M12x1

40

1

2

3

4

PBT, Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A

PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A

PBT, Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A

PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A

PBT, Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A

PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A

PBT,Black, nickel plated brasscoupling nutPG 7 cable glandAccepts 4-6 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A

PBT, Black, nickel plated brasscoupling nutPG 9 cable glandAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 125 V, 4 A

Page 43: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

41 GSEE TECH

Accessories

10091101

10091111EZ4112-1/11

EK4112-1/11

1

2

3

4

1

2

3

4

Field wireable connector Features

PBT,Black,nickel plated brasscoupling nutAccepts 6-8 mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A

Type NO. ID NO. Pinout

59 19.6

M12x1

63 20

M12x1

PBT, Black, nickel plated brasscoupling nutAccepts 2*(3-5) mm cable diameterAccepts 0.75 mm² Max.Screw terminals85°C, 250 V, 4 A

101130001011300110113002

EZ4-TH-2M/P00EZ4-TH-5M/P00EZ4-TH-10M/P00

10091800For BL67-2AI-TC, M12 x 1 roundconnector, fi eld wirable, screw-terminal connection,integrated Pt1000 sensor for cold junction point compensation

EZ4112-0/7-TH

61 19.6

M12x13

21

4

1

3

TC

2

4

PT1000

3

21

4

1BN

3BU

TC

2WH

4BK

PT1000

Features Type NO. ID NO. PinoutThe cold junction point compensation

For BL67-2AI-TC, M12 x 1 roundconnector, fi eld wirable, screw-terminal connection,integrated Pt1000 sensor for cold junction point compensation

61 19.6

M12x1

Page 44: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

42 GSEE TECH

102501121025011010250111102503911025038210250062102503891025038010250060102503901025038110250061581002515820025158210251582202511001732210016279100162671001721210017320100162771001626510017210100173211001627810016266100172111001733210016285100162731001722210017330100162831001627110017220100173311001628410016284100172211001733710016288100162761001722710017335100162861001627410017225100173361001628710016275100172261001732710016282100162701001721710017325100162801001626810017215100173261001628110016269

027027027031029026031029026031029026033035035035027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028026027030028

BRJ45-10M/F21BRJ45-2M/F21BRJ45-5M/F21BRJ45S-10M/F211BRJ45S-10M/F230BRJ45S-10M/F41BRJ45S-2M/F211BRJ45S-2M/F230BRJ45S-2M/F41BRJ45S-5M/F211BRJ45S-5M/F230BRJ45S-5M/F41CS022280-*MCS041580-*MCS041680-*MCS042280-*MEIK4-10M/F21EIK4-10M/F211EIK4-10M/F230EIK4-10M/F41EIK4-2M/F21EIK4-2M/F211EIK4-2M/F230EIK4-2M/F41EIK4-5M/F21EIK4-5M/F211EIK4-5M/F230EIK4-5M/F41EILK4-10M/F21EILK4-10M/F211EILK4-10M/F230EILK4-10M/F41EILK4-2M/F21EILK4-2M/F211EILK4-2M/F230EILK4-2M/F41EILK4-5M/F21EILK4-5M/F211EILK4-5M/F230EILK4-5M/F41EILZ4-10M/F21EILZ4-10M/F211EILZ4-10M/F230EILZ4-10M/F41EILZ4-2M/F21EILZ4-2M/F211EILZ4-2M/F230EILZ4-2M/F41EILZ4-5M/F21EILZ4-5M/F211EILZ4-5M/F230EILZ4-5M/F41EIZ4-10M/F21EIZ4-10M/F211EIZ4-10M/F230EIZ4-10M/F41EIZ4-2M/F21EIZ4-2M/F211EIZ4-2M/F230EIZ4-2M/F41EIZ4-5M/F21EIZ4-5M/F211EIZ4-5M/F230

100172161001112210011120100111211001113210011130100111311009110110091220100115421001154010011541100912001001115210011150100111511001116210011160100111611009122110011552100115501001155110011092100110901001109110011102100910301009103110091231100111001001110110011532100910321009103310011530100115311001304210013040100130411001300210013000100130011008501110013072100130701001307110013012100130101001301110013032100130301001303110013022100130201001302110085010100120421001204010012041100120021008100110012000

026038038038038038038041032038038038033038038038038038038032038038038037037037037040040032037037037040040037037034034034034034034034034034034034034034034034034034034034034033033033033033033

EIZ4-5M/F41EK3 EZ3-10M/P00EK3 EZ3-2M/P00EK3 EZ3-5M/P00EK4 EZ4-10M/P00EK4 EZ4-2M/P00EK4 EZ4-5M/P00EK4112-1/11EK4238-0/9EK5 EZ5-10M/P00EK5 EZ5-2M/P00EK5 EZ5-5M/P00EK5228-0/9ELK3 ELZ3-10M/P00ELK3 ELZ3-2M/P00ELK3 ELZ3-5M/P00ELK4 ELZ4-10M/P00ELK4 ELZ4-2M/P00ELK4 ELZ4-5M/P00ELK4238-0/9ELK5 ELZ5-10M/P00ELK5 ELZ5-2M/P00ELK5 ELZ5-5M/P00ELZ3-10M/P00ELZ3-2M/P00ELZ3-5M/P00ELZ4-10M/P00ELZ4112-0/7ELZ4112-0/9ELZ4238-0/9ELZ4-2M/P00ELZ4-5M/P00ELZ5-10M/P00ELZ5112-0/7ELZ5112-0/9ELZ5-2M/P00ELZ5-5M/P00ENK5 ENZ5-10MENK5 ENZ5-2MENK5 ENZ5-5MENK5-10MENK5-2MENK5-5MENK5-TRENLK5 ENLZ5-10MENLK5 ENLZ5-2MENLK5 ENLZ5-5MENLK5-10MENLK5-2MENLK5-5MENLZ5-10MENLZ5-2MENLZ5-5MENZ5-10MENZ5-2MENZ5-5MENZ5-TREPK5 EPZ5-10MEPK5 EPZ5-2MEPK5 EPZ5-5MEPK5-10MEPK5-2EPZ5-VEPK5-2M

Index

Type NO. ID NO. Page number Type NO. ID NO. Page number

Page 45: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

43 GSEE TECH

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

033033033033033033033033033033033033033033037037037037040041040041032037037041041041037040040033037037027030028026027030028026027030028026027030028026027030028026027030028026012010017016014

EPK5-5MEPLK5 EPLZ5-10MEPLK5 EPLZ5-2MEPLK5 EPLZ5-5MEPLK5-10MEPLK5-2MEPLK5-5MEPLZ5-10MEPLZ5-2MEPLZ5-5MEPZ5-10MEPZ5-2MEPZ5-5MEPZ5-TREZ3-10M/P00EZ3-2M/P00EZ3-5M/P00EZ4-10M/P00EZ4112-0/7EZ4112-0/7-THEZ4112-0/9EZ4112-1/11EZ4238-0/9EZ4-2M/P00EZ4-5M/P00EZ4-TH-10M/P00EZ4-TH-2M/P00EZ4-TH-5M/P00EZ5-10M/P00EZ5112-0/7EZ5112-0/9EZ5228-0/9EZ5-2M/P00EZ5-5M/P00FEIK41-10M/F21FEIK41-10M/F211FEIK41-10M/F230FEIK41-10M/F41FEIK41-2M/F21FEIK41-2M/F211FEIK41-2M/F230FEIK41-2M/F41FEIK41-5M/F21FEIK41-5M/F211FEIK41-5M/F230FEIK41-5M/F41FEIZ41-10M/F21FEIZ41-10M/F211FEIZ41-10M/F230FEIZ41-10M/F41FEIZ41-2M/F21FEIZ41-2M/F211FEIZ41-2M/F230FEIZ41-2M/F41FEIZ41-5M/F21FEIZ41-5M/F211FEIZ41-5M/F230FEIZ41-5M/F41GXDN-DI16GXDN-DI8GXDN-DI8DO8GXDN-DO16GXDN-DO8

A2060001A2060048A2060036A2060040A2060008A2060081A2060069A2060073A2060077A2060002A2060062A2060088A2060004A2060003A2060006A2060045A2060031A2060037A2060041A2060066A2060082A2060070A2060074A2060078A2060034A2060063A2060086A2060058A2060051A2060054A2060046A2060029A2060038A2060042A2060067A2060083A2060071A2060075A2060079A2060032A2060064A2060087A2060059A2060052A2060055A2060047A2060030A2060039A2060043A2060061A2060065A2060060A2060053A2060056A2060016A2060049A2060020A2060044A2060068A2060084A2060072A2060076A2060080

012013010011019023020021022017018024016014015012013010011019023020021022017018024016014015012013010011019023020021022017018024016014015012013010011017018016014015012013010011019023020021022

GXDP-DI16GXDP-DI16-1000GXDP-DI8GXDP-DI8-1000GXDP-DI8AI4GXDP-DI8AI4-0090GXDP-DI8AI4-0010GXDP-DI8AI4-0020GXDP-DI8AI4-0030GXDP-DI8DO8GXDP-DIO16GXDP-DIO8AO4-0009GXDP-DO16GXDP-DO8GXDP-DO8-0100GXEC-DI16GXEC-DI16-1000GXEC-DI8GXEC-DI8-1000GXEC-DI8AI4GXEC-DI8AI4-0090 GXEC-DI8AI4-0010GXEC-DI8AI4-0020GXEC-DI8AI4-0030GXEC-DI8DO8GXEC-DIO16GXEC-DIO8AO4-0009GXEC-DO16GXEC-DO8GXEC-DO8-0100GXEI-DI16GXEI-DI16-1000GXEI-DI8GXEI-DI8-1000GXEI-DI8AI4GXEI-DI8AI4-0090GXEI-DI8AI4-0010GXEI-DI8AI4-0020GXEI-DI8AI4-0030GXEI-DI8DO8GXEI-DIO16GXEI-DIO8AO4-0009GXEI-DO16GXEI-DO8GXEI-DO8-0100GXEN-DI16GXEN-DI16-1000GXEN-DI8GXEN-DI8-1000GXEN-DI8DO8GXEN-DIO16GXEN-DO16GXEN-DO8GXEN-DO8-0100GXPI-DI16GXPI-DI16-1000GXPI-DI8GXPI-DI8-1000GXPI-DI8AI4GXPI-DI8AI4-0090GXPI-DI8AI4-0010GXPI-DI8AI4-0020GXPI-DI8AI4-0030

Index

Type NO. ID NO. Page number Type NO. ID NO. Page number

Page 46: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but

44 GSEE TECH

Index

Type NO. ID NO. Page number Type NO. ID NO. Page number A2060022A2060025A2060085A2060023A2060017A2060057100330421003304010033041100330021009210110092102100330001003300110033072100330701003307110033012100330101003301110033032100330301003303110031042100310401003104110031002100310001003100110085021100310721003107010031071100310121003101010031011100310321003103010031031100310221003102010082000100310211008200110085020100330221009212110092122100330201008400010033021100912991025038510250376102500421025038310250374102500401025038410250375102500411025009210250090

017018024016014015036036036036039039036036036036036036036036036036036035035035035035035035035035035035035035035035035035035035035034035036039039036036036032031029026031029026031029026031029

GXPI-DI8DO8GXPI-DIO16GXPI-DIO8AO4-0009GXPI-DO16GXPI-DO8GXPI-DO8-0100MK5 MZ5-10MMK5 MZ5-2MMK5 MZ5-5MMK5-10MMK5211-0/11MK5211-0/13.5MK5-2MMK5-5MMLK5 MLZ5-10MMLK5 MLZ5-2MMLK5 MLZ5-5MMLK5-10MMLK5-2MMLK5-5MMLZ5-10MMLZ5-2MMLZ5-5MMNK5 MNZ5-10MMNK5 MNZ5-2MMNK5 MNZ5-5MMNK5-10MMNK5-2MMNK5-5MMNK5-TRMNLK5 MNLZ5-10MMNLK5 MNLZ5-2MMNLK5 MNLZ5-5MMNLK5-10MMNLK5-2MMNLK5-5MMNLZ5-10MMNLZ5-2MMNLZ5-5MMNZ5-10MMNZ5-2MMNZ5-2MNK5MNZ5-5MMNZ5-ENK5-MNK5MNZ5-TRMZ5-10MMZ5211-0/11MZ5211-0/13.5MZ5-2MMZ5-2MK5MZ5-5MRJ45/HMRJ45S-10M/F211RJ45S-10M/F230RJ45S-10M/F41RJ45S-2M/F211RJ45S-2M/F230RJ45S-2M/F41RJ45S-5M/F211RJ45S-5M/F230RJ45S-5M/F41SRJ45S-10M/F21SRJ45S-2M/F21

102500921025009010250091102501021025010010250101102503881025037910250052102503861025037710250050102503871025037810250051

027027027027027027031029026031029026031029026

SRJ45S-10M/F21SRJ45S-2M/F21SRJ45S-5M/F21TRJ45-10M/F21TRJ45-2M/F21TRJ45-5M/F21TRJ45S-10M/F211TRJ45S-10M/F230TRJ45S-10M/F41TRJ45S-2M/F211TRJ45S-2M/F230TRJ45S-2M/F41TRJ45S-5M/F211TRJ45S-5M/F230TRJ45S-5M/F41

Page 47: Company Profile - gsee-tech.com › ... › Download › ...2016-15201926176.pdfGeneuo exceptionally large product portfolio does not only cover all relevant standard solutions but