Commercial Permit Application New Building PUC Fee

10
Permit No.______________ PID No.________________ DATE RCVD.___________ 320 Oak Street South - Sauk Centre, MN 56378 Permit Fee $ Surcharge $ Plan Check $ City Fee $ Water Access $ Sewer Access $ PUC Fee $ Please Type or Print Legibly: 1. Site Address________________________________________________ Sauk Centre, MN 56378 2. Owner(s)__________________________________________Daytime Phone_____________________ 3. Owner's Address (if different from above)__________________________________________________ 4. Legal Description of Site: (Please Attach Metes & Bounds Description) Note* If unknown, please refer to property tax statement or ask Zoning Administrator 5. Zoning SETBACKS & LOT COVERAGE VARY IN THE DIFFERENT ZONING DISTRICTS 6. Type of Improvement: 7. Describe in detail work to be done________________________________________________________ ___________________________________________________________________________________ ___________________________________________________________________________________ 8. Building Covering Material(s) If Applicable __________________________________________________ 9. Approximate Start Date_______________________________ 10. Estimated Cost of Project (Including Materials & Labor ): $______________________ 11. Type of Construction: For Office Use Only Additional Information Requested On Reverse Ph: (320) 352-2203 FAX: (320) 352-0121 New Building Build_____ Addition_____ Remodel_____ Roof Only_____ Other_____ On Site_____ Modular_____ Prefabricated_____ Other______________(Explain) Commercial Permit Application Email: [email protected] 1 of 10

Transcript of Commercial Permit Application New Building PUC Fee

Permit No.______________PID No.________________DATE RCVD.___________

320 Oak Street South - Sauk Centre, MN 56378 Permit Fee $

Surcharge $

Plan Check $

City Fee $

Water Access $

Sewer Access $

PUC Fee $

Please Type or Print Legibly:

1. Site Address________________________________________________Sauk Centre, MN 56378

2. Owner(s)__________________________________________Daytime Phone_____________________

3. Owner's Address (if different from above)__________________________________________________

4. Legal Description of Site: (Please Attach Metes & Bounds Description)Note* If unknown, please refer to property tax statement or ask Zoning Administrator

5. Zoning SETBACKS & LOT COVERAGE VARY IN THE DIFFERENT ZONING DISTRICTS

6. Type of Improvement:

7. Describe in detail work to be done________________________________________________________

___________________________________________________________________________________

___________________________________________________________________________________

8. Building Covering Material(s) If Applicable __________________________________________________

9. Approximate Start Date_______________________________

10. Estimated Cost of Project (Including Materials & Labor ): $______________________

11. Type of Construction:

For Office Use Only

Additional Information Requested On Reverse

Ph: (320) 352-2203 FAX: (320) 352-0121

New Building

Build_____ Addition_____ Remodel_____ Roof Only_____ Other_____

On Site_____ Modular_____ Prefabricated_____ Other______________(Explain)

Commercial Permit Application

Email: [email protected]

1 of 10

12. Dimensions of Structure:___________________________

13. Number of Stories of Structure(s)______________________

14. Please Provide the Following: (If Applicable)

General Contractor ________________________________________PH:_______________________

Electrical Contractor _______________________________________PH:_______________________

Plumbing Contractor _______________________________________PH:_______________________

Mason & Concrete Contractor ________________________________PH:______________________

Heating & Venting Contractor ________________________________PH:_____________________

Excavation Contractor_______________________________________PH:_____________________

Sprinkler Contractor_________________________________________PH:_____________________

X Utilities Checklist (To Be Completed and Signed at Public Utilities Office) X Certificate of Survey (by licensend Land Surveyor) X TWO SETS of Construction Plans (Signed By Architect if Applicable)

_____Other___________________________________

AUTHORIZED SIGNATURE OF OWNER OR OWNER'S AGENT ZONING ADMINISTRATOR

This Permit Expires One Year From:_____________________ BUILDING OFFICAL

I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and

Ordinances governing this type of work will be complied with whether specified herein or not. I have identified all property

boundaries, easements, flood zones and/or wetlands existing on the property on my site plan and application.

The undersigned further agrees the City and its' adminstrative staff relied on the accurateness of this application, plans and specifications

relative to this project and holds the city of Sauk Centre,

and its employees harmless from all liability arising from the granting of this permit.

Required Forms & Items to Return with Application:

Your application will be deferred until all checked items above are provided.

2 of 10

Utilities Checklist

NOTE: This form must be presented to the Sauk Centre Public Utility Commission Office (101 Main St. S.) signed by a member of their staff and returned to the Planning & Zoning office before a building permit will be issued.

Will buifding require electrical heat?

Are you Installing an electric hot water heater?

Adding electric central air conditioning?

Do you require new electric service or or a change in service box location?

Date: ----------

Are there any changes to your present water service planned or a new line hook-up?

Are there any changes to your present sanitary sewer service planned or a new hookup?

If a disturbance to the street adjacent to the structure is needed for utility services, have you applied for a street opening permit from the City Hall?

Do you wish to know more about load management of electrical service?

YES

Will you be Installing a lawn sprinkler system? ___ _

Name:

Address:

NO NIA

Legal Description: _______________________________ _

General Contractor: Electrician: ---------- -------------------

Plumber: Excavator: _________________ _

REMINDERS: 1. There shall be Installed in all new buildings a remote reading water meter adjacent to the electric meter.

The owner must install a half inch (1/2) PVC conduit from the water meter location to the electric meter socketpanel on the outside of the building. Conduit shall be placed within six (6) inches alongside the conduit of theelectric meter socket panel and a minimum of two (2) feet above grade.

2. There will be NO removal of dirt in the public road right-of-way or the public easement.There are many different utility services located In the R-0-W and easements, therefore,the elevation and coverage cannot be changed.

3. Customers with new sewer & water hookups to the sanitary sewer & water mains shall pay both sewer andwater access charges (SAC & WAC). The WAC charge is $. ____ for a (1) inch service line or smallerThe SAC charge Is $. ____ for upto and including a (4) inch service line. Services over these sizes will be addressed on an individual basis. This charge Is to be paid along with the building pennit fee at City Hall.

Public Utilities Signature

Property Owner/Applicant Signature

Date

Date

Initial______

Initial______

Initial______

3 of 10

Erosion Control Requirements Landscaping and Grading

It is the intent of the City of Sauk Centre to satisfy the appropriate water quality requirements of the Clean Water Act and the Environmental Protection Agency’s (EPA) Storm Water Phase II of the National Pollutant Discharge Elimination System (NPDES) storm water program.

Provisions shall be made to the maximum extent practical for construction related activities to assure:

• Public streets remain clean• The water quality of our water bodies and wetlands is protected and enhanced• Discharge of sediments and pollutant runoff into storm drains is reduced or eliminated• Surrounding properties will be minimally affected by erosion and runoff

Construction activities which include: clearing, grading or excavating land shall provide for effective control of erosion, sediments and all other pollutants. The property owners or construction site operators shall be responsible for the installation and monitoring of erosion and sediment controls and best management practices (BPM’s). Such controls will be monitored through the building permit inspection process.

At minimum, the following BPM’s shall be implemented:

• Silt fencing around areas of disturbed soilSilt fencing shall be placed around the outer edge of all areas in accordance withthe details shown on the back. On typical residential lots, the placement shall bewithin 3' of the lot line. The City will determine those areas that require siltfence based on the site plan submitted, but the city reserves the right to requireadditional silt fence at any time as determined necessary. A sample of erosioncontrol requirements is on the reverse side illustrating the details for installationof silt fencing.

• Stabilized construction entrancesUsing soil to bridge the curb line or cross the street is PROHIBITED. Plywoodor wood planking may be used or curb cuts or driveway aprons may becompleted for entrance.

• Temporary rock construction entrancesTemporary rock entrances shall be placed at all access points to a constructionsite. The installation of more than one access point shall be reviewed andapproved by the City. The rock entrances shall be a minimum of 12 feet in widthand 20 feet long and shall be placed in accordance with the details shown on theback.

I have read, understand and agree to the above requirements.

Signed: Date:

4 of 10

iF ,! ii

HEAV

Y DU

TY S

ILT

FENC

E IF

PON

D OR

W

ETLA

ND IS

PRE

SENT

PO

NDIN

G AR

EA

-l' SI

LT F

ENCE

AT L

OT

FRON

T AN

D BA

CK

HEAV

Y DU

TY S

ILT

FENC

E AL

ONG

BACK

OF

CURB

,-

--

--

--

--

--

--

-7

I /

BIOR

OLL

INST

ALLE

D IN

I

SWAL

E BO

TTOM

(TYP)

0

1.

INST

ALL

SILT

FEN

CE P

ER D

ETAI

L ER

O-2,

ALO

NG B

ACK

AND

SIDE

PRO

PERTY

LIN

ES.

2. IN

STAL

L HE

AVY

DUTY

SIL

T FE

NCE

PER

DETAI

L ER

O-3,

ALO

NG B

ACK

OF C

URB.

3.

IN

STAL

L BI

OROL

LS A

LONG

SID

E OF

LO

T AS

AN

ALTE

RNAT

IVE

WHE

N SW

ALED

TO

DRAI

N TO

FRO

NT A

ND/O

R BA

CK O

F LO

T, S

EE D

ETAI

L ER

O-6.

4.

IF T

HERE

IS A

WET

LAND

OR

POND

ING

AREA

ADJ

ACEN

T TO

LOT

, HEA

VY D

UTY S

ILT

FENC

E SH

ALL

BE IN

STAL

LED

ALON

G TH

AT S

IDE

OF L

OT.

5.

CREAT

E ON

E TE

MPO

RARY

CON

STRU

CTION

ENT

RANC

E PE

R LO

T, S

EE D

ETAI

L ER

O-5.

6. IN

STAL

L IN

LET

PROT

ECTI

ON O

N ST

ORM

STR

UCTUR

ES S

USCE

PTIBL

E TO

RUN

OFF

FROM

LO

T, S

EE D

ETAI

L ER

O-4,

AS

DETER

MIN

ED B

Y CI

TY.

()s

tante

c E

RO

SIO

N C

ON

TR

OL F

OR

LO

T G

RA

DIN

G

SA

UK

CE

NT

RE

, M

INN

ES

OT

A

CURB

AND

GU

TTER

(TYP)

LAST REV

ISIO

N:

MAR

CH 2

016

PLA

TE

NO

.

ER

O-1

J'l l,

h

�;

r I J

STEE

L FE

NCE

POST

(T-P

OST)

, M

INIM

UM 5

' LON

G, 6

' M

AXIM

UM S

PAO

NG.

STEE

L PO

STS:

POST

NOT

CHES

TO

FAC

E AW

AY

FROM

FAB

RIC.

DIRE

CTION

OF

SURF

ACE

FLOW

STEE

L PO

STS:

ATTAC

H FA

BRIC

TO

POSTS

W

ITH

MIN

IMUM

3 Z

IP TI

ES

(50

LB. T

ENSI

LE)

PER

POST

IN

TOP

8" O

F FA

BRIC

.

MON

OFIL

AMEN

T GE

OTEXTT

LE

FABR

IC P

ER M

NDOT

TAB

LE

3886

-1 (M

ACHI

NE S

LICE

D).

MAC

HINE

SLI

CE

/, .. .,. '"'"

'''""" ""

'

. . . · • .• ·• .·

· .. • · · . _J �

:::��::,,,,

NOTE

: TH

E M

ACHI

NE S

LICE

D M

ETHO

D (T

HIS

DETA

IL) I

S TH

E ST

ANDA

RD SI

LT

FENC

E IN

STAL

LATI

ON M

ETHO

D. H

EAVY

DUTY

(ERO

-3) S

ILT

FENC

E IN

STAL

LATI

ON M

ETHO

DS S

HOUL

D BE

USE

D W

HERE

DIR

ECTED

IN E

RO-1

.

@ CO

MPA

CTIO

N:

AFTER

"SL

ICIN

G" I

N TH

E FA

BRIC

AND

BE

FO

RE

INS

TALL

ATIO

N OF

STE

EL P

OSTS,

DRIV

E IN

STAL

LATI

ON E

QUI

PMEN

T OV

ER T

HE "

SLIC

E" W

HILE

FAB

RIC

IS L

AYIN

G ON

THE

GROU

ND.

THE

N I

NSTA

LL T

HE P

OSTS

AND

PUL

L UP

FAB

RIC

TO A

TTAC

H AT

A U

NIFO

RM H

EIGH

T.

() S

tant

ec

MA

CH

INE

SLIC

ED

SIL

T F

EN

CE

SA

UK

CE

NT

RE

, M

INN

ES

OTA

LAST REV

ISIO

N:

MAR

CH 2

016

PLA

TE

NO

.

ER

O-2

5 of 10

6 of 10

7 of 10

A Certificate of Survey by a MN Registered Land Surveyor is required with all applications for new construction. The survey should include at minimum:

* Legal description of the property and site address* Lot dimensions* North Point and Graphic Scale* All adjacent streets, alleys, easements, utilities (water, sewer and electric) and overhead power lines* Footprint of ALL structures with ALL setbacks and dimensions noted* Elevation of all lot corners, the building pad, side front and rear yard lines, elevations at all low

openings or all lookout/walkouts, garage slab elevation, top of footing elevation, lowest floorelevation, top of block elevation and curb elevation

* Drainage arrows showing how the lot is to drain* Percent of driveway slope and width of curb cut at the street (calculate slope at center of driveway)* Distance to reference points from lot corner along lot line to verify building placement

Additionally, the Building Official requires TWO sets of Construction Plans drawn to scale. An approved set of plans will be returned to you; the second set will be filed with the City. The following items must be included on all construction plans (as applicable):

* Floor plan of basement and each floor above* Fire protection between building and any attached structure* Foundation drainage* Names and addresses of: General Contractor, Plumber, Mechanical, Electrician

* Cross Section detailing foundation, footings, wall roof, steps, deck (as applicable)

The following standards apply for C-2 zoning district:

Site Requirements: Minimum Lot Area - 12,000 (all uses) Minimum Lot Width - 80' Maximum Lot Coverage - 50% Structure Requirements:

Maximum Height - 50' Setback Requirements: Front Setback - 25' Rear Setback - 20' Side Setback - 15' Side Street Corner Setback - 25' Corner lots at street intersections shall maintain front yard setbacks on each street side

Commercial New Construction Building Permit Request Requirements

Please contact the Planning/Zoning Office with questions at (320) 352-2203.

8 of 10

X 12

54.1

4

CE

RTI

FIC

ATE

�F

S �R

VE

Y \

1256

.69

\ \

h M

AN

HOLE

12

55.7

5 12

562

5 /({'

®

\

X

X 12

55 8

8 X

/

-X

1256

.61

. X l

1257

.22

12

55.9

1 '--

'--2-5

6. CI

CI------.

/

/

--

--

1257

. 00-

--

-I

1257

.90

\

[ '\

S88

° 53'1

3"W

--------/

\

� -'!-

--

--

--

463.

52

__

--

--

-1 2

5a_ 0

0 �

12

57.5

4 \

\ %

\

_1,.,

12

55.6

3 12

55.9

9 __

-'--

---------

. --

J.-_--

_�8_.

7_ 2 ;r-. J_

. _

. -

---

. _ x...-

...,"/

\ · 9-

/

<55

.........:.;.

·--=

·�.

-. -

•,,...... __:x

-= -

X -

-_.____

-,,;u

'-"

\

-Do�

125

5.02

• .

-/

B

UIL

DIN

G S

ET-

BA

CK

,,,-__

_...,2

57_ 95

::

--

--

x�

-

--

--;,7

_--

'\-

� �

_r--

-x

1255

.18\

/

/

/ --c:

--

-""'

1259

.48:::J:

A,'o

5<-

<s 0

· c

� ........ �..

\'I,,�

.

/

_____

I (

I

�o�

_---l

-----

---:--

--:---

-1 --:.

x"o

· 12

59_5

5·0 �

\

�12

59.8

1

\ �

/

____ ----

I / I

12

61.0

@])

· \

'----

\)}

-\

X 12

56.4

8

/

/ -

1257

.62

\

1259

.30

'A.

\.

·6

QC\

x \

I x

x

· y

\.

\

,,.,,,,--'\

'2-5 .

/ �

-78

BU

ILD

ING

-�

<,

-

\_

_ /

x

1256

.18

/ �

I

,,•,,,,

,,..__

S

ET-

BA

CK

'l,,'or;::,

�r;::,

R

\

/ /

/

\ 12

59.7

7 /

' \

x

9o

----

\

\

/

\ 12

60.�

. /

MAN

HOLE

'--.__

I

/

§

/

/

:�,-a;;-

�=

,,,...._,....

;::;..;.;;;;;;;.

.,.i...;;."c

; /

.Ji',,;i Ji..

':'6'•·:\.'1

�"-12

61.6

'0/

1262

.�

'--.__

�-

I

/

x1'2

/>$39'7'

0 �

>�

.• v,,,

.,,,,,.

,n7

.. . · ...

.. ,.,.,.

. .,,,""

-''

( ,,,,,

"--

y

II

��

��

��

��

/

"--

,

"'-.

_ __,,

\-_.-

1�57

.21

/ x

12

i8.

7J

=.1.,

, ... ,,,

�,,.

x 12

64.4

4, C

o,v.

.......__

----.

§

1258

.34

\ ,,,

',CT

,,C..-�

/

q

C

-_

x

\

!fr.

/x

1265

.6l

!i>s

1257

.20 \

:::i

\

----

---'

/

I

I ----.

'----/ X

1258

.04

I

\

1259

.40

1259

.55

,,,--

-_

-_.-

1262

.99

\/

---

\

/

/ ---

1261

82

----

----X

1262

.43

/ _../

. \

/

12

60.9

9 /

x

. (

/ \

\

J 12

59.9

7 x;

\

\ /

X "'

"'

/L--,

\

I X

1258

.44

1258

.75"'-.

"'-.

\

-........--,

"'-.

"'-.

\ \

\ �

"'-.

"'-.

\

\ \

\�

"'-. "'-.

\

\ )

-�"'-.

"'-.

\

o1

t5!

""-\

4.62

Ac.

± x

1262

.31

" '-G>

a'?9

��

"'

(201

,313

Sq.F

t.±)

/ /

'-...

0

·&

-�

\

\ \

/

'-..,

u))?'.

(S)

X 12

58.3

1 X

1 /

--.....

��

\V

o x

1258

.05

/

1259

.59

I I

/x

1259

.87

"-�

'f-

/

/

X 12

65.9

5 "'

·/

I I

I I

I"..

"'

_

-\-

�1 2 s9

_00

..__

__

/

\ I

I 1

1263

. �6

"' /

'--I

I12

62.7

6 I

Imp

erv

iou

s A

rea

Ca

lcu

lati

on

"' \

/

"--.. I

X

I I

"'

/

"'-)1

1259

.9�

I I

/ :.--

---12

60 oo

--

<1--1--,

"' "'-.

/

--

----\

. X

1260

.40

/ /

/ /

/ ----

.x 12

60.6

0 I I

I

I /

/

X 12

60.6

8

\

;I

I I

/ /

I d,

I I

I I

NI�

oo

.

""' ""'

0

LO

O

C"l

o

0

0

0

0

O

lo

·o

oo

o_,;.

\

I /

(Cl

..:

c\i

c,j

xr-J

1

� re

re re

re

1264

.63

g?,

· 1

\

Prop

osed

Bui

ldin

g 4,

800

S.F.

\

I ....

,.....

....

....

Cl

a>

I\

/ / x

I

1 /

0

·o12

61.1

8 I

; o

\

X 12

67.1

2

Gra

vel s

urfac

es

18,4

74 S

.F.

Tota

l Im

perv

ious

23

,274

S.F

. To

tal L

ot A

rea

/201

,313

S.F

. 11

.6%

Impe

rvio

us

/ "-"

X

"'

�\

I I I

I /

; \ ·

\ /

\ /

j f

\ /

\

)

x 12

67.4

0

I \

I I

I I

/12

65.7

7 .

J g

1259

.75

"'

--

MA

NHO

LE

1�8.

17

X 12

69.2

2

X 12

68.8

8

1=60

��

0

0

( )

60

120

SC

AL

E I

N F

EE

T

INP

LAC

E IR

ON

MO

NU

ME

NT

1/2"

IRO

N R

EB

AR

WIT

H P

LAS

TIC

C

AP

STA

MP

ED

"R

LS 4

2620

" &

"RLS

453

35"

RE

CO

RD

DA

TA

DIR

EC

TIO

N O

F D

RA

INA

GE

--

-UE

--

-U

ND

ER

GR

OU

ND

ELE

C. L

INE

I her

eby

certi

fy th

at th

is s

urve

y, p

lan

or re

port

was

pr

epar

ed b

y m

e or

und

er m

y di

rect

sup

ervi

sion

and

th

at I

am a

dul

y R

egis

tere

d La

nd S

urve

yor u

nder

th

e la

ws

of th

e St

ate

of M

inne

sota

.

Brad

M. N

yber

g Da

te

Mar

ch 2

2nd,

201

8 Li

cens

e N

o. 4

2620

SEC

. 21

T 13

4 N

R 3

6 W

"'

I\

I

I \

\ I

X

!�

DA

TE

: 3

/22

/20

18

DR

AW

N B

Y:

TM

H

CH

EC

KE

D:

BM

N

JO

B N

O.

96

95

Lega

l Des

crip

tion:

Lo

t 1, B

lock

1, S

AUK

CENT

RE

IND

UST

RIA

L PA

RK

"' "' \

I

\ I

I �

\

\ I

· T

_',.!

I

I I

I12

638:

r r

; I

I D

AV

E E

KE

\

\ \x

1261

.15

\

\ ·

\ [

/ x

RE

QU

ESTE

D B

Y:

·\

\\

\ I

I ;

J 15

1k

67.6

9...,.. _

__

__

__

__

__

__

__

__

__

__

__

__

__

...,.

Prop

erty

Add

ress

: 41

4 Li

ncol

n Lo

op

Sauk

Cen

tre, M

N 5

6378

X

1259

.43

X 12

59.5

0

'l,, ��

__

\

__

_ \_

�U

I LOIN

!3�

-�A

f!S.+. -

----\·

11

tJ N

yb

er

g

509

22N

DAV

E.E

AS

T,S

UIT

E1

01

\ \

2155_

12

� 1

2�6.

3 JI

=='

__

__

..,._._

__

__

AL

EXA

ND

RIA,

�IN

NE

SOTA

563

08

---

-;

1260

.37

N8 9

° 5 7'5

8"E

/

1265

.20

/

--

--

I � .....

, S

UR

VEVIN

r.!!! P

H. (

320)

762-

4111

FA

X_(3

20)7

62-4

112

..... �

.a

w

ww

.nyb

ergs

urve

ymg.

com

EXAMPLE

EXAM

PLE

9 of 10

Commercial Structure

North Property Line 100’

East Property Line 200 feet

25 feet m

inimum

25 feet Minimum Setback

(street corner)

15 feet Minimum Setback

20 feet M

inimum

Setback

North

South Property Line 100’

West Property Line 200 feet

(Owner’s Name) Site Plan

Lot 1 Block 1 Original Townsite

Scale 1” = 20’

10’ wide Utility easement

Example Site Plan C-2

Center Line of Street

10 of 10