Page 1: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

COMMERCIAL CEMENT PLASTER 1

DS824

Fiberglass Reinforced Portland Cement Plaster

Applied to Concrete or CMU

Commercial Cement Plaster 1 Installation Details

Page 2: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

TABLE OF CONTENTS

Opening Preparation-Backstop NT/AquaFlashâ System Option

Metal Lath with Backstopâ NTOption

CMU SubstratesConcrete Substrates

DETAIL PAGE

CCP-1 0.0.01CCP-1 0.0.02CCP-1 0.0.03

DRYVIT MAKES NO REPRESENTATION REGARDING CONFORMITY OFITS SUGGESTIONS TO MODEL BUILDING CODES, ENGINEERINGCRITERIA, SPECIFIC APPLICATIONS OR PROJECT LOCATIONS. ALLCOMPONENTS INDICATED IN ILLUSTRATIONS, AS WELL ASOTHERS THAT MAY BE REQUIRED FOR THE INTEGRITY OF THESYSTEM SHALL BE DESIGNED, DETAILED AND ENGINEERED BYREPRESENTATIVES OF THE ARCHITECT, OWNER OR CONTRACTORTO BE IN CONFORMANCE WITH MODEL CODES, ARCHITECTURALAND ENGINEERING REQUIREMENTS PERTAINING TO SPECIFICBUILDING PROJECTS.

DRYVIT MAKES NO WARRANTY, EXPRESSED OR IMPLIED, AS TOTHE ARCHITECTURAL DESIGN, ENGINEERING, OR WORKMANSHIP OFPROJECTS UTILIZING DRYVIT SYSTEMS OR PRODUCTS.

THE LIABILITIES OF DRYVIT SHALL BE AS STATED IN THEDRYVIT STANDARD WARRANTY. CONTACT DRYVIT FOR A FULLAND COMPLETE COPY OF THIS WARRANTY.

NOTE

CCP-1 0.0.05

Commercial Cement Plaster 1™

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Dryvit Systems, Inc. 1969

Issued: 10/2017

CCP-1 0.0.04Masonry Substrate- ReinforcedBase Coat

Page 3: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

CONCRETE SUBSTRATE

CONCRETE SUBSTRATEWITH LATH

Concrete Substrates

CCP-1 0.0.01

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Dryvit Systems, Inc. 1969

Issued: 10/2017

Commercial Cement Plaster 1™NOTE:

1. WHEN SPECIFIED.2. OTHER APPROVED SCRATCH AND BROWN

COATS MAY BE ACCEPTABLE. CONSULTDRYVIT SYSTEMS, INC. FOR SPECIFICS.

AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
AC 100 BONDING AGENT BONDING AGENT (NOTE 1)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
GALVANIZED SELF-FURRING LATH (BY OTHERS)
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASE (NOTE 2)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASE (NOTE 2)
Page 4: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

CCP-1 0.0.02

MASONRY SUBSTRATEWITH LATH

MASONRY SUBSTRATE

CMU Substrates

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Dryvit Systems, Inc. 1969

Issued: 10/2017

Commercial Cement Plaster 1™NOTE:

1. WHEN SPECIFIED.2. OTHER APPROVED SCRATCH AND BROWN

COATS MAY BE ACCEPTABLE. CONSULTDRYVIT SYSTEMS, INC. FOR SPECIFICS.

AutoCAD SHX Text
CMU (BY OTHERS)
AutoCAD SHX Text
GALVANIZED SELF-FURRING LATH (BY OTHERS)
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASE (NOTE 2)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
FLUSH MORTAR JOINT (BY OTHERS)
AutoCAD SHX Text
CMU (BY OTHERS)
AutoCAD SHX Text
AC 100 BONDING AGENT BONDING AGENT (NOTE 1)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
FLUSH MORTAR JOINT (BY OTHERS)
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASE (NOTE 2)
Page 5: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

CCP-1 0.0.03

CONCRETE SUBSTRATEWITH LATH/ BACKSTOP NT

AIR/WATER-RESISTIVE BARRIER

MASONRY SUBSTRATEWITH LATH/BACKSTOP NT

AIR/WATER-RESISTIVE BARRIER

â

Metal Lath with Backstop NT Option

ä

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Dryvit Systems, Inc. 1969

Issued: 10/2017

Commercial Cement Plaster 1™NOTE:

1. SKIM COAT WITH DRYVIT GENESIS REQUIREDOVER ROUGH OR UNEVEN SUBSTRATES.

2. A SLIP SHEET IS REQUIRED WHEN USING DRYVIT BACKSTOP NT.3. OTHER APPROVED SCRATCH AND BROWN

COATS MAY BE ACCEPTABLE. CONSULTDRYVIT SYSTEMS, INC. FOR SPECIFICS.

AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
GALVANIZED SELF-FURRING LATH (BY OTHERS)
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASE (NOTE 3)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
CMU WITH JOINTS STRUCK FLUSH (BY OTHERS) (NOTE 1)
AutoCAD SHX Text
GALVANIZED SELF-FURRING LATH (BY OTHERS)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
DRYVIT BACKSTOPâ NT AIR/WATER- NT AIR/WATER- RESISTIVE BARRIER (WHEN SPECIFIED)
AutoCAD SHX Text
DRYVIT BACKSTOP NT AIR/WATER- NT AIR/WATER- RESISTIVE BARRIER (WHEN SPECIFIED)
AutoCAD SHX Text
#15 FELT, OR EQUAL, SLIP SHEET (BY OTHERS) (NOTE 2)
AutoCAD SHX Text
#15 FELT, OR EQUAL, SLIP SHEET (BY OTHERS) (NOTE 2)
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASEä (NOTE 3)
Page 6: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

MASONRY SUBSTRATE WITH DRYVIT BASE COATAND EMBEDDED REINFORCING MESH

CCP-1 0.0.04

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Dryvit Systems, Inc. 1969

Issued: 10/2017

Commercial Cement Plaster 1™NOTE:

1. WHEN SPECIFIED.2. OTHER APPROVED SCRATCH AND BROWN

COATS MAY BE ACCEPTABLE. CONSULTDRYVIT SYSTEMS, INC. FOR SPECIFICS.

® ™

Masonry Substrate-

Reinforced Base Coat

AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
AC 100 BONDING AGENT BONDING AGENT (NOTE 1)
AutoCAD SHX Text
DRYVIT FINISH
AutoCAD SHX Text
DRYVIT PRIMER
AutoCAD SHX Text
COMMERCIAL CEMENT PLASTER BASE (NOTE 2)
AutoCAD SHX Text
DRYVIT REINFORCING MESH EMBEDDED IN GENESIS® OR GENESIS DM LEVELING COAT OR GENESIS DM LEVELING COATOR GENESIS DM LEVELING COATLEVELING COAT
Page 7: COMMERCIAL CEMENT PLASTER 1 DS824 - Dryvit · commercial cement plaster 1 ™ note: 1.when specified. 2.other approved scratch and brown coats may be acceptable. consult dryvit systems,

CCP-1 0.0.05

INSTALL DIAGONAL STRIPOF DRYVIT AQUAFLASHMESH AND AQUAFLASHAT CORNERS(NOTES 1 AND 3)

APPLY DRYVIT AQUAFLASHSYSTEM (NOTES 1 AND 2)

DRYVIT BACKSTOP NTAIR/WATER-RESISTIVEBARRIER COATING

STEP #1 STEP #2

INSTALL DRYVIT AQUAFLASHSYSTEM AT JAMBS(NOTES 1 AND 2)

STEP #3 STEP #4

INSTALL DRYVITAQUAFLASH SYSTEMAT HEADS(NOTES 1 AND 2)

Opening Preparation-

Backstopâ NT/AquaFlashâ System

©

The architecture, engineering, and design of the project using the

Dryvit products is the responsibility of the project's design

professional. All systems must comply with local building codes and

standards. This detail is for general information and guidance only

and Dryvit specifically disclaims any liability for the use of this detail

and for the architecture, design, engineering or workmanship of any

project. The project design professional determines, in its sole

discretion, whether this detail or a functionally equivalent detail is

best suited for the project. Use of a functionally equivalent detail does

not violate Dryvit's warranty. This detail is subject to change without

notice. Contact Dryvit to ensure you have the most recent version.

Dryvit Systems, Inc. 1969

Issued: 10/2017

Commercial Cement Plaster 1™NOTE:

1. DRYVIT AQUAFLASH SHALL EXTEND TOINTERIOR FACE OF OPENING.

2. INSTALL WINDOW UNIT AND ASSOCIATEDFLASHINGS PER MANUFACTURER'SRECOMMENDATIONS, CODE REQUIREMENTS ANDPROJECT DOCUMENTS.