Commercial Air Conditioners 2016 - MIDEA...
Transcript of Commercial Air Conditioners 2016 - MIDEA...
-
1604-1R1603
Commercial Air Conditioners 2016
R410A 50Hz
Rooftop Package
iOS Version Android Version
Midea CAC After-service Application
iOS Version
Midea CAC News Application
Commercial Air Conditioner DivisionMidea GroupAdd.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China
Postal code: 528311
Tel: +86-757-26338346 Fax: +86-757-22390205
cac.midea.com global.midea.com
Note: The data in this book may be changed without notice for further improvement on
quality and performance.
-
There are three production bases: Shunde, Chongqing and Hefei.
MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU.
MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled Screw/Scroll Chillers,
and AHU/FCU.
MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters.
Midea CACMidea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation
and air conditioning solutions. Midea CAC has continued with the tradition of innovation upon which it was founded, and
emerged as a global leader in the HVAC industry. A strong drive for advancement has created a groundbreaking R&D
department that has placed Midea CAC at the forefront of a competitive field. Through these independent efforts and joint
cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide.
2015 JV with Carrier in China in chiller field, BOSCH in VRF production and Siix in smart control
2014 Launched the rooftop package ClimaCreator globally
2010 Built the 3rd manufacturing base in Hefei
2008 Launched the rooftop package ClimaMaster globally
2007 Won the first Midea centrifugal chiller project overseas
2006 Launched the first VSD centrifugal chiller
2004 Acquired MGRE entered the chiller industry
2001 Partnered with Copeland to develop the digital scroll VRF system
2000 Developed the first inverter VRF With Toshiba
1999 Entered the CAC field
Midea Company Introduction
Midea CAC Introduction
-
There are three production bases: Shunde, Chongqing and Hefei.
MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU.
MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled Screw/Scroll Chillers,
and AHU/FCU.
MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters.
Midea CACMidea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation
and air conditioning solutions. Midea CAC has continued with the tradition of innovation upon which it was founded, and
emerged as a global leader in the HVAC industry. A strong drive for advancement has created a groundbreaking R&D
department that has placed Midea CAC at the forefront of a competitive field. Through these independent efforts and joint
cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide.
2015 JV with Carrier in China in chiller field, BOSCH in VRF production and Siix in smart control
2014 Launched the rooftop package ClimaCreator globally
2010 Built the 3rd manufacturing base in Hefei
2008 Launched the rooftop package ClimaMaster globally
2007 Won the first Midea centrifugal chiller project overseas
2006 Launched the first VSD centrifugal chiller
2004 Acquired MGRE entered the chiller industry
2001 Partnered with Copeland to develop the digital scroll VRF system
2000 Developed the first inverter VRF With Toshiba
1999 Entered the CAC field
Midea Company Introduction
Midea CAC Introduction
-
03 04
Intr
oduc
tion
Introduction
Midea rooftop package air conditioners are designed and manufactured to off the all-in-one solutions for large halls, ware-
houses or other appliations.
Midea rooftop package air conditioner are totally two series: ClimaCreator series and ClimaMaster series.
380~415V 3Ph~ 50Hz
T1
T1
Tropical (T3)
380~415V 3Ph~ 50Hz
Heat pump
Heat pump
Cooling only
7.5RT~25RT
Tropical (T3) Cooling only 4RT~30RT
3RT~5RT
Heat pump 6.2RT~30RT
Cooling only+EHK 6.2RT~30RT
5RT~30RT
R410A
ClimaCreator series
R410A
ClimaMaster series
Power supply Application Function Cooling capactity rangeSeries
Notes: 1. Product’s cooling capacity as per specification.
Golden Dragen Mart1,320RTBarka, Oman
Traki Store560RTValencia, Venezuela
Contents
22 ClimaMaster Series
41 Controllers
10 ClimaCreator Series
05 General Features
10 Product lineups
11 Specifications16 Dimensions
22 Product lineups
23 Specifications
33 Dimensions
-
03 04
Intr
oduc
tion
Introduction
Midea rooftop package air conditioners are designed and manufactured to off the all-in-one solutions for large halls, ware-
houses or other appliations.
Midea rooftop package air conditioner are totally two series: ClimaCreator series and ClimaMaster series.
380~415V 3Ph~ 50Hz
T1
T1
Tropical (T3)
380~415V 3Ph~ 50Hz
Heat pump
Heat pump
Cooling only
7.5RT~25RT
Tropical (T3) Cooling only 4RT~30RT
3RT~5RT
Heat pump 6.2RT~30RT
Cooling only+EHK 6.2RT~30RT
5RT~30RT
R410A
ClimaCreator series
R410A
ClimaMaster series
Power supply Application Function Cooling capactity rangeSeries
Notes: 1. Product’s cooling capacity as per specification.
Golden Dragen Mart1,320RTBarka, Oman
Traki Store560RTValencia, Venezuela
Contents
22 ClimaMaster Series
41 Controllers
10 ClimaCreator Series
05 General Features
10 Product lineups
11 Specifications16 Dimensions
22 Product lineups
23 Specifications
33 Dimensions
-
05 06
General Features
Gen
eral
Fea
ture
s
Gen
eral
Fea
ture
s
Removable access door on the electric box. It is easy to
move the cover of the electric box.
Only connect the wires of power supply, and no need
to connect any signal wires.
Convenient for wires connection
Easy to installation
Reserved external drainage port, quickly and accurately
connect the rubber drainage pipe.
Easily connect the drainage pipe
Famous brand compressor: Copeland, Hitachi, Danfoss,
etc. More reliable.
No complex internal suction and discharge valves for
quieter operation and higher reliability.
Compact, light-weight design, and fewer moving parts
design.
Reliable scroll compressor
The rooftop package air conditioners with special anti-corrosion treatment are suitable for seaside areas or the areas
exposed to acidic substances.
Customized anti-corrosion treatment
Multi-measurement to ensure units operate normally
and reliably:
System current protection, High/low pressure switch
protection, Temperature sensor on/off protection, etc.
Three-phase protector can be customized.
Multi-protection design
Temperature sensorHP/LP switch
Special anti-corrosion treatment of heat exchanger
provides 5 to 6 times greater resistance against acid
rain and salt corrosion.
All PCB parts in the unit are coated with double-side
moisture proof paint. The outer side of electric box
metal cover is spray-painted.
All screws are anti-rust.
Casings of the unit and motors are anti-rust.
Convenient for unit selection
Wide cooling capacity range, from 36000Btu/h to 360000Btu/h.
Wide cooling capacity range
Compact design.
Flanges of air flow inlet and outlet as standard.
It is suitable for installation in rooftop and ground.
Design �exibility
Pre-painted exterior cabinet panels pass 1000 hours Salt Spray Test for durability.
Weather-resistant construction with capped steams and sloped top panels.
G90 galvanized heavy gauge plate conforming to ASTM-A-653.
Durable construction
Outstanding reliability
ClimaMaster series ClimaCreator series
-
05 06
General Features
Gen
eral
Fea
ture
s
Gen
eral
Fea
ture
s
Removable access door on the electric box. It is easy to
move the cover of the electric box.
Only connect the wires of power supply, and no need
to connect any signal wires.
Convenient for wires connection
Easy to installation
Reserved external drainage port, quickly and accurately
connect the rubber drainage pipe.
Easily connect the drainage pipe
Famous brand compressor: Copeland, Hitachi, Danfoss,
etc. More reliable.
No complex internal suction and discharge valves for
quieter operation and higher reliability.
Compact, light-weight design, and fewer moving parts
design.
Reliable scroll compressor
The rooftop package air conditioners with special anti-corrosion treatment are suitable for seaside areas or the areas
exposed to acidic substances.
Customized anti-corrosion treatment
Multi-measurement to ensure units operate normally
and reliably:
System current protection, High/low pressure switch
protection, Temperature sensor on/off protection, etc.
Three-phase protector can be customized.
Multi-protection design
Temperature sensorHP/LP switch
Special anti-corrosion treatment of heat exchanger
provides 5 to 6 times greater resistance against acid
rain and salt corrosion.
All PCB parts in the unit are coated with double-side
moisture proof paint. The outer side of electric box
metal cover is spray-painted.
All screws are anti-rust.
Casings of the unit and motors are anti-rust.
Convenient for unit selection
Wide cooling capacity range, from 36000Btu/h to 360000Btu/h.
Wide cooling capacity range
Compact design.
Flanges of air flow inlet and outlet as standard.
It is suitable for installation in rooftop and ground.
Design �exibility
Pre-painted exterior cabinet panels pass 1000 hours Salt Spray Test for durability.
Weather-resistant construction with capped steams and sloped top panels.
G90 galvanized heavy gauge plate conforming to ASTM-A-653.
Durable construction
Outstanding reliability
ClimaMaster series ClimaCreator series
-
07 08
Multi-accessories
EHK (Electric Heater Kits) √
√
√ √
√
√
√
√
√
√
√
√
√
√
√
√
Filter
Three-phase protector
Network interface module
Anti-corrosion fin
Drainage pipe
Snap ring
Outlet drainage
Description
Standard accessories Optional accessories
ClimaCreator series ClimaMaster series
Standard accessories Optional accessories
The unit provides external pressure gauge ports for convenient and fast checking
system pressure without removing the panel.
External pressure gauge ports
Removable the access doors on the filter, fan motor, and electric box sections.
Provide convenient access to system components for mainenance and service.
Easy access doors design
Press the ‘Check’ button, the LED display in PCB board of the unit will dislay the normal checking code.
If the unit is in running with abnormal operation, the LED display will show the error code.
System self-diagnostic
Washable �lter
Easy to maintenance
Electric box
Access panel for electric box
Flexible choise of accessories
CCM30
Max.64
MD-NIM01 MD-NIM01 MD-NIM01 MD-NIM01
Centralized control function can be achieved through the centralized controller as optional. MD-NIM01 should be
connected between rooftop package units and centralized controller.
Controllers
Wired controller as standard.
Besides standard wired controller, others can be chosen too.
KJR-12B/dP(T)-E
Other brand thermostat can be matched as optional solution.
Non-programmable thermostat
SW3: set to 1SW3
Gen
eral
Fea
ture
s
Gen
eral
Fea
ture
s
-
07 08
Multi-accessories
EHK (Electric Heater Kits) √
√
√ √
√
√
√
√
√
√
√
√
√
√
√
√
Filter
Three-phase protector
Network interface module
Anti-corrosion fin
Drainage pipe
Snap ring
Outlet drainage
Description
Standard accessories Optional accessories
ClimaCreator series ClimaMaster series
Standard accessories Optional accessories
The unit provides external pressure gauge ports for convenient and fast checking
system pressure without removing the panel.
External pressure gauge ports
Removable the access doors on the filter, fan motor, and electric box sections.
Provide convenient access to system components for mainenance and service.
Easy access doors design
Press the ‘Check’ button, the LED display in PCB board of the unit will dislay the normal checking code.
If the unit is in running with abnormal operation, the LED display will show the error code.
System self-diagnostic
Washable �lter
Easy to maintenance
Electric box
Access panel for electric box
Flexible choise of accessories
CCM30
Max.64
MD-NIM01 MD-NIM01 MD-NIM01 MD-NIM01
Centralized control function can be achieved through the centralized controller as optional. MD-NIM01 should be
connected between rooftop package units and centralized controller.
Controllers
Wired controller as standard.
Besides standard wired controller, others can be chosen too.
KJR-12B/dP(T)-E
Other brand thermostat can be matched as optional solution.
Non-programmable thermostat
SW3: set to 1SW3
Gen
eral
Fea
ture
s
Gen
eral
Fea
ture
s
-
09 10
Mechanical speci�cation
Product lineups
ClimaCreator Series
Through changing the working pitch diameter of the pulley
mounted on driver shaft, in turn the revolutions per minute of the
driven shaft will increase or decrease to change air volume.
Adjustable pulley
Three thickness filter: 0.5inch, 1inch and 2inch;
Two kinds of filter materials: Metal or Nylon + Metal frame.
EHK (Electric Heater Kits) and control box can be customized.
Air intake �lter & EHK as optional
T1
Applications
Tropical (T3)
Applications
Nominal ton* 4 5 6.2 7.5 8.5 10 12.5 17.515 20 25 30
Notes:
1. * Nominal ton only for reference.
2. means cooling type product; means heat pump type product.
3. Cooling or heating capacity as per specifications.
Gen
eral
Fea
ture
s
Clim
aCre
ator
Ser
ies
GeneralThe units are convertible airflow. All units are factory assembled, internally wired, fully charged refrigerant and 100% run tested to check cooling and heating operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit is colored and numbered for simplified identification. The unit is provided with an integral weather resistant control panel.
CasingUnit casing is constructed of Zinc coated, heavy gauge, galvanized steel. Exterior surfaces are cleaned, G90 galvanized heavy gauge plate conforming to ASTMA 653, followed by baked on electrostatic polyester dry powder coat paint on all external panels, completely weatherized for outdoor installation and propely reinforced and brazed. Salt Spray Test for steel sheet under 1000 hours, specially treated can be up to 2000 hours and even more. Cabinet contruction allows for all maintenance. Service panels are removed easily and reinstalled by removing bolts. All panels and top covers indoor side of the unit are insulated with 16mm, foam-faced, closed-cell insulation. The unit has provisions for forklift and crane lifting, with forklift capabilities on four sides of the unit.
CompressorsAll units have direct-drive, hermetic, scroll type compressors with centrifugal type oil pump. Motor is suction gas-cooled and has a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads are provided with the scroll compressors.Compressors used in Rooftop Package unit are hermetically sealed reciprocating type. They are equipped with a crankcase heater as standard.The compressors, incorporating a built-in muffler, are mounted on spring within a heavy gauge steel housing to give a low noise level.The unit contains the best compressor technology available to achieve the highest possible performance. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applicaitons.
ControlsThe unit is completely factory-wired with necessary controls and terminal block for power wiring. The unit provides an external location for mounting a fused disconnect device.Microprocessor controls provide for all 24V control functions. The precision control makes all heating, cooling, or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures.The control maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized micro-processor provides a higher level of machine protection.
CoilsInternally finned, copper tubes mechanically bonded to a configured hydrophilic aluminum fin is standard. Coils are leak tested under 3100KPa (450 psig) at the factory to ensure the pressure integrity.
Electronic thermostatsGeneral information: A dedicated electronic thermostat is supplied with unit controls as standard. It controls one or two stage cooling applications. The thermostat normally displays room temperature and mode of operation. It also allows to select continuous fan operation, or has the fan on intermittent operation with the equipment. Finally, it displays the status of unit, thus providing maximum information for the user.
-
09 10
Mechanical speci�cation
Product lineups
ClimaCreator Series
Through changing the working pitch diameter of the pulley
mounted on driver shaft, in turn the revolutions per minute of the
driven shaft will increase or decrease to change air volume.
Adjustable pulley
Three thickness filter: 0.5inch, 1inch and 2inch;
Two kinds of filter materials: Metal or Nylon + Metal frame.
EHK (Electric Heater Kits) and control box can be customized.
Air intake �lter & EHK as optional
T1
Applications
Tropical (T3)
Applications
Nominal ton* 4 5 6.2 7.5 8.5 10 12.5 17.515 20 25 30
Notes:
1. * Nominal ton only for reference.
2. means cooling type product; means heat pump type product.
3. Cooling or heating capacity as per specifications.
Gen
eral
Fea
ture
s
Clim
aCre
ator
Ser
ies
GeneralThe units are convertible airflow. All units are factory assembled, internally wired, fully charged refrigerant and 100% run tested to check cooling and heating operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit is colored and numbered for simplified identification. The unit is provided with an integral weather resistant control panel.
CasingUnit casing is constructed of Zinc coated, heavy gauge, galvanized steel. Exterior surfaces are cleaned, G90 galvanized heavy gauge plate conforming to ASTMA 653, followed by baked on electrostatic polyester dry powder coat paint on all external panels, completely weatherized for outdoor installation and propely reinforced and brazed. Salt Spray Test for steel sheet under 1000 hours, specially treated can be up to 2000 hours and even more. Cabinet contruction allows for all maintenance. Service panels are removed easily and reinstalled by removing bolts. All panels and top covers indoor side of the unit are insulated with 16mm, foam-faced, closed-cell insulation. The unit has provisions for forklift and crane lifting, with forklift capabilities on four sides of the unit.
CompressorsAll units have direct-drive, hermetic, scroll type compressors with centrifugal type oil pump. Motor is suction gas-cooled and has a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads are provided with the scroll compressors.Compressors used in Rooftop Package unit are hermetically sealed reciprocating type. They are equipped with a crankcase heater as standard.The compressors, incorporating a built-in muffler, are mounted on spring within a heavy gauge steel housing to give a low noise level.The unit contains the best compressor technology available to achieve the highest possible performance. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applicaitons.
ControlsThe unit is completely factory-wired with necessary controls and terminal block for power wiring. The unit provides an external location for mounting a fused disconnect device.Microprocessor controls provide for all 24V control functions. The precision control makes all heating, cooling, or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures.The control maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized micro-processor provides a higher level of machine protection.
CoilsInternally finned, copper tubes mechanically bonded to a configured hydrophilic aluminum fin is standard. Coils are leak tested under 3100KPa (450 psig) at the factory to ensure the pressure integrity.
Electronic thermostatsGeneral information: A dedicated electronic thermostat is supplied with unit controls as standard. It controls one or two stage cooling applications. The thermostat normally displays room temperature and mode of operation. It also allows to select continuous fan operation, or has the fan on intermittent operation with the equipment. Finally, it displays the status of unit, thus providing maximum information for the user.
-
11 12
T1 application, 380-415V 3Ph~ 50Hz
Speci�cations Speci�cations
6.2RT & 7.5RT 8.5RT & 10RT 12.5RT
T1 application, 380-415V 3Ph~ 50Hz
15RT 17.5RT & 20RT 25RT & 30RT
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Heating capacity test condition (2):
Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Heating capacity test condition (2):
Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
Nominal ton*
Cooling
Heating
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
Cooling
Heating
DimensionNet (W×H×D)
Weight
Ambienttemperature
Wired controller
Net / Gross
Packing (W×H×D)
CapacityBtu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input
EER
Capacity
Input
COP
Type \ Quantity
Brand
75,000
22.0
6.6
11.4
89,000
26.0
7.5
11.9
2,800
Default: 80; 0~250
18.3
Scroll / 1
Copeland
Centrifugal / Direct
Axial / Direct
KJR-25B
8,600
MRC-062HWN1-R(C)
1,475×840×1,130
1,495×870×1,150
229/234
10°C~46°C
6.2
89,000
26.0
7.9
11.3
103,000
30.0
8.9
11.6
2,830
Default: 80; 0~250
24.8
Scroll / 1
Danfoss
Axial / Direct
KJR-25B
Centrifugal / Direct
12,000
MRC-075HWN1-R(C)
1,475×840×1,130
1,495×870×1,150
325/335
10°C~46°C
7.5
103,000
30.0
9.3
11.1
120,000
35.0
10.6
11.3
3,500
Default: 80; 0~200
26.5
Scroll / 2
Hitachi
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
13,600
MRC-085HWN1-R(C)
1,483×1,138×1,231
1,500×1,255×1,155
340/350
10°C~46°C
8.5
120,000
35.0
10.7
11.2
137,000
40.0
11.9
11.5
4,100
Default: 90; 0~250
28.8
Scroll / 2
Hitachi
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
16,000
MRC-100HWN1-R(C)
1,483×1,138×1,231
1,500×1,255×1,155
343/354
10°C~46°C
10
150,000
44.0
13.3
11.3
154,000
45.0
13.2
11.7
5,500
Default: 110; 0~275
38.2
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller (Optional) No No Yes Yes Yes
Centrifugal / Belt
19,700
MRC-125HWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
451/471
10°C~46°C
-9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C
12.5
-9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C
Nominal ton*
Cooling
Heating
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Wired controller
Net / Gross
Packing (W×H×D)
CapacityBtu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input
EER
Capacity
Input
COP
Type \ Quantity
Brand
180,000
53.0
16.7
10.8
191,000
56.0
17.2
11.1
7,000
Default: 110; 0~325
46.1
Scroll / 2
Copeland
Centrifugal / Belt
Axial / Direct
KJR-12B/dP(T)-E
25.0
MRC-150HWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
492/512
10°C~46°C
15
208,000
61.0
19.1
10.9
218,000
64.0
19.5
11.2
7,600
Default: 110; 0~250
55.4
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
27.0
MRC-175HWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
615/645
10°C~46°C
17.5
240,000
70.0
22.6
10.6
260,000
75.0
23.6
11.0
8,800
Default: 120; 0~375
63.2
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
32.5
MRC-200HWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
690/720
10°C~46°C
20
300,000
88.0
28.9
10.4
330,000
97.0
30.3
10.9
10,000
Default: 130; 0~350
74.3
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
38.5
MRC-250HWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
940/970
10°C~46°C
25
335,000
98.0
32.8
10.2
380,000
111.5
36.5
10.4
11,200
Default: 270; 25~400
81.7
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller (Optional) Yes Yes Yes Yes Yes
Centrifugal / Belt
49.5
MRC-300HWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
955/985
10°C~46°C
30
Ambienttemperature
Cooling
Heating
-
11 12
T1 application, 380-415V 3Ph~ 50Hz
Speci�cations Speci�cations
6.2RT & 7.5RT 8.5RT & 10RT 12.5RT
T1 application, 380-415V 3Ph~ 50Hz
15RT 17.5RT & 20RT 25RT & 30RT
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Heating capacity test condition (2):
Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Heating capacity test condition (2):
Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
Nominal ton*
Cooling
Heating
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
Cooling
Heating
DimensionNet (W×H×D)
Weight
Ambienttemperature
Wired controller
Net / Gross
Packing (W×H×D)
CapacityBtu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input
EER
Capacity
Input
COP
Type \ Quantity
Brand
75,000
22.0
6.6
11.4
89,000
26.0
7.5
11.9
2,800
Default: 80; 0~250
18.3
Scroll / 1
Copeland
Centrifugal / Direct
Axial / Direct
KJR-25B
8,600
MRC-062HWN1-R(C)
1,475×840×1,130
1,495×870×1,150
229/234
10°C~46°C
6.2
89,000
26.0
7.9
11.3
103,000
30.0
8.9
11.6
2,830
Default: 80; 0~250
24.8
Scroll / 1
Danfoss
Axial / Direct
KJR-25B
Centrifugal / Direct
12,000
MRC-075HWN1-R(C)
1,475×840×1,130
1,495×870×1,150
325/335
10°C~46°C
7.5
103,000
30.0
9.3
11.1
120,000
35.0
10.6
11.3
3,500
Default: 80; 0~200
26.5
Scroll / 2
Hitachi
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
13,600
MRC-085HWN1-R(C)
1,483×1,138×1,231
1,500×1,255×1,155
340/350
10°C~46°C
8.5
120,000
35.0
10.7
11.2
137,000
40.0
11.9
11.5
4,100
Default: 90; 0~250
28.8
Scroll / 2
Hitachi
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
16,000
MRC-100HWN1-R(C)
1,483×1,138×1,231
1,500×1,255×1,155
343/354
10°C~46°C
10
150,000
44.0
13.3
11.3
154,000
45.0
13.2
11.7
5,500
Default: 110; 0~275
38.2
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller (Optional) No No Yes Yes Yes
Centrifugal / Belt
19,700
MRC-125HWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
451/471
10°C~46°C
-9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C
12.5
-9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C -9°C~24°C
Nominal ton*
Cooling
Heating
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Wired controller
Net / Gross
Packing (W×H×D)
CapacityBtu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input
EER
Capacity
Input
COP
Type \ Quantity
Brand
180,000
53.0
16.7
10.8
191,000
56.0
17.2
11.1
7,000
Default: 110; 0~325
46.1
Scroll / 2
Copeland
Centrifugal / Belt
Axial / Direct
KJR-12B/dP(T)-E
25.0
MRC-150HWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
492/512
10°C~46°C
15
208,000
61.0
19.1
10.9
218,000
64.0
19.5
11.2
7,600
Default: 110; 0~250
55.4
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
27.0
MRC-175HWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
615/645
10°C~46°C
17.5
240,000
70.0
22.6
10.6
260,000
75.0
23.6
11.0
8,800
Default: 120; 0~375
63.2
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
32.5
MRC-200HWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
690/720
10°C~46°C
20
300,000
88.0
28.9
10.4
330,000
97.0
30.3
10.9
10,000
Default: 130; 0~350
74.3
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
38.5
MRC-250HWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
940/970
10°C~46°C
25
335,000
98.0
32.8
10.2
380,000
111.5
36.5
10.4
11,200
Default: 270; 25~400
81.7
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller (Optional) Yes Yes Yes Yes Yes
Centrifugal / Belt
49.5
MRC-300HWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
955/985
10°C~46°C
30
Ambienttemperature
Cooling
Heating
-
13 14
Tropical (T3) application, 380-415V 3Ph~ 50Hz
Speci�cations
6.2RT & 7.5RT 8.5RT
Speci�cationsTropical (T3) application, 380-415V 3Ph~ 50Hz
8.5RT & 10RT 12.5RT
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Nominal ton*
Cooling
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type \ Quantity
Brand
48,000
12.4
Scroll / 1
Copeland
Centrifugal / Direct
Axial / Direct
KJR-12B/dP(T)-E
6.2
MRCT-48CWN1-R(C)
1,310×840×900
1,340X865X935
167/170
10°C~52°C
4
58,000
15.5
Scroll / 1
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Direct
7.4
MRCT-60CWN1-R(C)
1,310×840×900
1,340X865X935
180/183
10°C~52°C
5
75,000
22.0
6.6
11.4
61,400
18.0
7.8
7.9
2,800
Default: 80; 0~250
19.3
Scroll / 1
Copeland
Axial / Direct
KJR-25B
Centrifugal / Direct
9.0
MRCT-062CWN1-R(C)
1,475×840×1,130
1,495×870×1,150
223/228
10°C~52°C
6.2
89,000
26.0
7.9
11.3
69,600
20.4
9.0
7.8
2,830
Default: 80; 0~250
14.1
4.1
11.7
39,000
11.4
4.8
8.1
1,750
Default: 75; 0~200
17.0
5.0
11.6
47,900
14.0
5.9
8.1
2,000
Default: 75; 0~200
27.2
Scroll / 1
Danfoss
Axial / Direct
KJR-25B
Centralized controller (Optional) Yes Yes No No
Centrifugal / Direct
13.6
MRCT-075CWN1-R(C)
1,475×840×1,130
1,495×870×1,150
231/236
10°C~52°C`
7.5
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Nominal ton*
Cooling
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type \ Quantity
Brand
102,000
30.0
9.2
11.1
80,700
23.7
10.3
7.9
3,500
Default: 80; 0~200
29.2
Scroll / 2
Hitachi
Centrifugal / Belt
Axial / Direct
KJR-12B/dP(T)-E
14.8
MRCT-085CWN1-R(C)
1,483×1,231×1,138
1,500×1,255×1,155
331/342
10°C~52°C
8.5
102,000
30.0
9.2
11.1
80,700
23.7
10.3
7.9
3,500
Default: 80; 0~200
29.2
Scroll / 1
Copeland
Axial / Direct
KJR-23B
Centrifugal / Belt
14.8
MRCT-085WN1-R(D)
1,483×1,231×1,138
1,500×1,255×1,155
302/313
10°C~52°C
8.5
120,000
35.0
10.7
11.2
100,200
29.4
12.6
8.0
4,100
Default: 90; 0~250
34.1
Scroll / 2
Hitachi
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
18.0
MRCT-100CWN1-R(C)
1,483×1,231×1,138
1,500×1,255×1,155
335/346
10°C~52°C
10
120,000
35.0
10.7
11.2
100,200
29.4
12.6
8.0
4,100
Default: 90; 0~250
34.1
Scroll / 1
Copeland
Axial / Direct
KJR-23B
Centrifugal / Belt
18.0
MRCT-100CWN1-R(D)
1,483×1,231×1,138
1,500×1,255×1,155
323/335
10°C~52°C
10
150,000
44.0
13.3
11.3
125,400
36.8
16.1
7.8
5,500
Default: 110; 0~275
41.2
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller (Optional) Yes No Yes No Yes
Centrifugal / Belt
21.0
MRCT-125CWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
433/453
10°C~52°C
12.5
4RT & 5RT
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
13 14
Tropical (T3) application, 380-415V 3Ph~ 50Hz
Speci�cations
6.2RT & 7.5RT 8.5RT
Speci�cationsTropical (T3) application, 380-415V 3Ph~ 50Hz
8.5RT & 10RT 12.5RT
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Nominal ton*
Cooling
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type \ Quantity
Brand
48,000
12.4
Scroll / 1
Copeland
Centrifugal / Direct
Axial / Direct
KJR-12B/dP(T)-E
6.2
MRCT-48CWN1-R(C)
1,310×840×900
1,340X865X935
167/170
10°C~52°C
4
58,000
15.5
Scroll / 1
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Direct
7.4
MRCT-60CWN1-R(C)
1,310×840×900
1,340X865X935
180/183
10°C~52°C
5
75,000
22.0
6.6
11.4
61,400
18.0
7.8
7.9
2,800
Default: 80; 0~250
19.3
Scroll / 1
Copeland
Axial / Direct
KJR-25B
Centrifugal / Direct
9.0
MRCT-062CWN1-R(C)
1,475×840×1,130
1,495×870×1,150
223/228
10°C~52°C
6.2
89,000
26.0
7.9
11.3
69,600
20.4
9.0
7.8
2,830
Default: 80; 0~250
14.1
4.1
11.7
39,000
11.4
4.8
8.1
1,750
Default: 75; 0~200
17.0
5.0
11.6
47,900
14.0
5.9
8.1
2,000
Default: 75; 0~200
27.2
Scroll / 1
Danfoss
Axial / Direct
KJR-25B
Centralized controller (Optional) Yes Yes No No
Centrifugal / Direct
13.6
MRCT-075CWN1-R(C)
1,475×840×1,130
1,495×870×1,150
231/236
10°C~52°C`
7.5
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Nominal ton*
Cooling
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type \ Quantity
Brand
102,000
30.0
9.2
11.1
80,700
23.7
10.3
7.9
3,500
Default: 80; 0~200
29.2
Scroll / 2
Hitachi
Centrifugal / Belt
Axial / Direct
KJR-12B/dP(T)-E
14.8
MRCT-085CWN1-R(C)
1,483×1,231×1,138
1,500×1,255×1,155
331/342
10°C~52°C
8.5
102,000
30.0
9.2
11.1
80,700
23.7
10.3
7.9
3,500
Default: 80; 0~200
29.2
Scroll / 1
Copeland
Axial / Direct
KJR-23B
Centrifugal / Belt
14.8
MRCT-085WN1-R(D)
1,483×1,231×1,138
1,500×1,255×1,155
302/313
10°C~52°C
8.5
120,000
35.0
10.7
11.2
100,200
29.4
12.6
8.0
4,100
Default: 90; 0~250
34.1
Scroll / 2
Hitachi
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
18.0
MRCT-100CWN1-R(C)
1,483×1,231×1,138
1,500×1,255×1,155
335/346
10°C~52°C
10
120,000
35.0
10.7
11.2
100,200
29.4
12.6
8.0
4,100
Default: 90; 0~250
34.1
Scroll / 1
Copeland
Axial / Direct
KJR-23B
Centrifugal / Belt
18.0
MRCT-100CWN1-R(D)
1,483×1,231×1,138
1,500×1,255×1,155
323/335
10°C~52°C
10
150,000
44.0
13.3
11.3
125,400
36.8
16.1
7.8
5,500
Default: 110; 0~275
41.2
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller (Optional) Yes No Yes No Yes
Centrifugal / Belt
21.0
MRCT-125CWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
433/453
10°C~52°C
12.5
4RT & 5RT
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
15 16
DimensionsClimaCreator seriesTropical (T3) application: MRCT-48CWN1-R(C), MRCT-60CWN1-R(C)(Units: mm)
Speci�cationsTropical (T3) application, 380-415V 3Ph~ 50Hz
15RT 17.5RT & 20RT 25RT & 30RT
Maintain ori�ce for air supply motor
Hole for bottom installation8-15x25
887 1294
840
60273
5181310
63
42169
647900
736776
211
238
478
211
855
900
39612651310
518
60
100 314
280 280
180
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Nominal ton*
Cooling
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (T1)Btu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input (T1)
EER (T1)
Capacity (T2)
Input (T2)
EER (T2)
Type \ Quantity
Brand
180,000
53.0
16.7
10.8
146,000
42.8
18.7
7.8
7,000
Default: 110; 0~325
48.0
Scroll / 2
Copeland
Centrifugal / Belt
Axial / Direct
KJR-12B/dP(T)-E
25.0
MRCT-150CWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
470/490
10°C~52°C
15
208,000
61.0
19.1
10.9
181,100
53.1
22.6
8.0
7,600
Default: 110; 0~250
55.0
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
26.5
MRCT-175CWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
590/620
10°C~52°C
17.5
240,000
70.0
22.6
10.6
199,200
58.4
25.1
7.9
8,800
Default: 120; 0~375
66.9
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
33.0
MRCT-200CWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
670/700
10°C~52°C
20
300,000
87.0
28.0
10.7
251,700
73.8
32.0
7.9
10,000
Default: 110; 0~350
77.4
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
40.5
MRCT-250CWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
895/925
10°C~52°C
25
360,000
105.0
34.3
10.5
336,300
98.6
41.8
8.0
12,000
Default: 270; 0~400
94.1
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes Yes Yes
Centrifugal / Belt
49.5
MRCT-300CWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
910/940
10°C~52°C
30
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
15 16
DimensionsClimaCreator seriesTropical (T3) application: MRCT-48CWN1-R(C), MRCT-60CWN1-R(C)(Units: mm)
Speci�cationsTropical (T3) application, 380-415V 3Ph~ 50Hz
15RT 17.5RT & 20RT 25RT & 30RT
Maintain ori�ce for air supply motor
Hole for bottom installation8-15x25
887 129484
0
60273
5181310
63
42169
647900
736776
211
238
478
211
855
900
39612651310
518
60
100 314
280 280
180
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Units are suitable for operation to ±20% of nominal CFM;
3. Specifications are subject to change without prior notice for product improvement.
* Nominal ton only for reference.
Cooling or heating capacity as per specifications.
Nominal ton*
Cooling
Model
Air flow Indoor side
ESP
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (T1)Btu/h
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
mm
mm
kg
kW
kW
A
Input (T1)
EER (T1)
Capacity (T2)
Input (T2)
EER (T2)
Type \ Quantity
Brand
180,000
53.0
16.7
10.8
146,000
42.8
18.7
7.8
7,000
Default: 110; 0~325
48.0
Scroll / 2
Copeland
Centrifugal / Belt
Axial / Direct
KJR-12B/dP(T)-E
25.0
MRCT-150CWN1-R(C)
1,965×1,230×1,130
1,995×1,255×1,160
470/490
10°C~52°C
15
208,000
61.0
19.1
10.9
181,100
53.1
22.6
8.0
7,600
Default: 110; 0~250
55.0
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
26.5
MRCT-175CWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
590/620
10°C~52°C
17.5
240,000
70.0
22.6
10.6
199,200
58.4
25.1
7.9
8,800
Default: 120; 0~375
66.9
Scroll / 2
Copeland
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
33.0
MRCT-200CWN1-R(C)
1,670×1,247×2,192
1,695×1,284×2,212
670/700
10°C~52°C
20
300,000
87.0
28.0
10.7
251,700
73.8
32.0
7.9
10,000
Default: 110; 0~350
77.4
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centrifugal / Belt
40.5
MRCT-250CWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
895/925
10°C~52°C
25
360,000
105.0
34.3
10.5
336,300
98.6
41.8
8.0
12,000
Default: 270; 0~400
94.1
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes Yes Yes
Centrifugal / Belt
49.5
MRCT-300CWN1-R(C)
2,320×1,245×2,220
2,330×1,275×2,230
910/940
10°C~52°C
30
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
17 18
ClimaCreator series T1 application: MRC-062HWN1-D(C), MRC-075HWN1-R(C)Tropical (T3) application: MRCT-062CWN1-R(C), MRCT-075CWN1-R(C)(Units: mm)
Condenser fan
Maintain ori�ce for air supply motor
Hole for bottom installation8-15x20
1459111
5
840
6063
280
6681475
42189
8571130
60
306
102
1016966
1430668 404
231
1085
668
1130
1475
370327
328
294
310
285
370
327
310
328
294
285
ClimaCreator seriesT1 application: MRC-085HWN1-R(C), MRC-100HWN1-R(C)Tropical (T3) application: MRCT-085CWN1-R(C), MRCT-085CWN1-R(D), MRCT-100CWN1-R(C), MRCT-100CWN1-D(C)(Units: mm)
Condenser fan
Maintain ori�ce for air supply motor
1462
1117
1222
123
123388
700
105
105
284
560
39242
3
338 36
9
165
580 60
4
952
982
1130
820
655
105
180
559
1090
180
1130
655
952982
581
369
339
423392
123265265 70014351475
Hole for bottom installation10-15x20
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
17 18
ClimaCreator series T1 application: MRC-062HWN1-D(C), MRC-075HWN1-R(C)Tropical (T3) application: MRCT-062CWN1-R(C), MRCT-075CWN1-R(C)(Units: mm)
Condenser fan
Maintain ori�ce for air supply motor
Hole for bottom installation8-15x20
1459111
5
840
6063
280
6681475
42189
8571130
60
306
102
1016966
1430668 404
231
1085
668
1130
1475
370327
328
294
310
285
370
327
310
328
294
285
ClimaCreator seriesT1 application: MRC-085HWN1-R(C), MRC-100HWN1-R(C)Tropical (T3) application: MRCT-085CWN1-R(C), MRCT-085CWN1-R(D), MRCT-100CWN1-R(C), MRCT-100CWN1-D(C)(Units: mm)
Condenser fan
Maintain ori�ce for air supply motor
1462
1117
1222
123
123388
700
105
105
284
560
39242
3
338 36
9
165
580 60
4
952
982
1130
820
655
105
180
559
1090
180
1130
655
952982
581
369
339
423392
123265265 70014351475
Hole for bottom installation10-15x20
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
19 20
ClimaCreator seriesT1 application: MRC-125HWN1-R(C), MRC-150HWN1-R(C)Tropical (T3) application: MRCT-125CWN1-R(C), MRCT-150CWN1-R(C)(Units: mm)
Hole for bottom installation 12-15x20
74506 801 506
232
232
665
74
972
467
555
335
67 165
67165666
75
75508
800
508
Condenser fan
Maintain ori�ce for air supply motor
1130
1965
1227
1115 1953
ClimaCreator seriesT1 application: MRC-175HWN1-R(C), MRC-200HWN1-RTropical (T3) application: MRCT-175CWN1-R(C), MRCT-200CWN1-R(C)(Units: mm)
Condenser fan
Compressor panel
Hole for bottom installation14-15×20
8×Φ4
.2
14×Φ4.2
Horizontal supply opening
Horizontal return opening
Maintain ori�ce for air supply motor
21711654
1247
2192125
125800
125
695
8001670 125434
Control panel
2192
569
804
569
125
1670800 310 12520
2014
512
438 394 394 394
404 315 403 578
102 512 512 512
32.5
641
2520
230
020
232
731
108
297
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
19 20
ClimaCreator seriesT1 application: MRC-125HWN1-R(C), MRC-150HWN1-R(C)Tropical (T3) application: MRCT-125CWN1-R(C), MRCT-150CWN1-R(C)(Units: mm)
Hole for bottom installation 12-15x20
74506 801 506
232
232
665
74
972
467
555
335
67 165
67165666
75
75508
800
508
Condenser fan
Maintain ori�ce for air supply motor
1130
1965
1227
1115 1953
ClimaCreator seriesT1 application: MRC-175HWN1-R(C), MRC-200HWN1-RTropical (T3) application: MRCT-175CWN1-R(C), MRCT-200CWN1-R(C)(Units: mm)
Condenser fan
Compressor panel
Hole for bottom installation14-15×20
8×Φ4
.2
14×Φ4.2
Horizontal supply opening
Horizontal return opening
Maintain ori�ce for air supply motor
21711654
1247
2192125
125800
125
695
8001670 125434
Control panel
2192
569
804
569
125
1670800 310 12520
2014
512
438 394 394 394
404 315 403 578
102 512 512 512
32.5
641
2520
230
020
232
731
108
297
Clim
aCre
ator
Ser
ies
Clim
aCre
ator
Ser
ies
-
21 22
ClimaCreator seriesT1 application: MRC-250HWN1-R(C), MRC-300HWN1-R(C)Tropical (T3) application: MRCT-250CWN1-R(C), MRCT-300CWN1-R(C)(Units: mm)
Hole for wiresDrain connection hole
Maintain ori�ce for air supply motor
Condenser fan
Horizontal supply opening
Horizontal return opening
Hole for bottom installation
16-15×20
2220900
1245
9002320
130 130650 450900
130130
500500
900
490300
450 450 4501960
450
450
320
300
360
640 2
5025
0
Product lineups
ClimaMaster Series
Notes:
1. * Nominal ton only for reference.
2. means cooling type product; means cooling type product with EHK; means heat pump type product.
3. Cooling or heating capacity as per specifications.
T3Applications
T1Applications
Nominal ton* 543 6.2 7.5 10 15 17.5 20 3012.58.5
Clim
aCre
ator
Ser
ies
Clim
aMas
ter S
erie
s
-
21 22
ClimaCreator seriesT1 application: MRC-250HWN1-R(C), MRC-300HWN1-R(C)Tropical (T3) application: MRCT-250CWN1-R(C), MRCT-300CWN1-R(C)(Units: mm)
Hole for wiresDrain connection hole
Maintain ori�ce for air supply motor
Condenser fan
Horizontal supply opening
Horizontal return opening
Hole for bottom installation
16-15×20
2220900
1245
9002320
130 130650 450900
130130
500500
900
490300
450 450 4501960
450
450
320
300
360
640 2
5025
0
Product lineups
ClimaMaster Series
Notes:
1. * Nominal ton only for reference.
2. means cooling type product; means cooling type product with EHK; means heat pump type product.
3. Cooling or heating capacity as per specifications.
T3Applications
T1Applications
Nominal ton* 543 6.2 7.5 10 15 17.5 20 3012.58.5
Clim
aCre
ator
Ser
ies
Clim
aMas
ter S
erie
s
-
23 24
Speci�cationsT1 application, heat pump, 380~415V 3Ph~ 50Hz
Model
ESP
Nominal ton*
Cooling
Heating
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Centralized controller
Net / Gross
Packing (W×H×D)
Side-discharge Side-discharge Side-discharge
36,000 48,000 58,000
10.55 14.07 17.29
3.05 4.79 5.64
11.8 10.0 10.3
37,500 51,500 62,500
10.99 15.09 18.32
3.00 4.56 5.21
12.5 11.3 12.0
1,500 1,858 2,045
50 50 50
4.25 6.05 7.05
6.4 8.8 10.9
Scroll / 1 Scroll / 1 Scroll / 1
Copeland Copeland Copeland
Centrifugal / Direct
Axial / Direct Axial / Direct Axial / Direct
- - -
Centrifugal / Direct Centrifugal / Direct
MRC-36HWN1-R MRC-48HWN1-R MRC-60HWN1-R
Type
Btu/h
kW
Btu/h.W
CFM
Pa
1,116×830×744
No No No
1,116×830×744 1,116×830×744
1,152×855×765 1,152×855×765 1,152×855×765
139/142 146/149 159/162
21°C~43°C 21°C~43°C 21°C~43°C
mm
mm
kg
kW
Btu/h
kW
Btu/h.W
kW
kW
A
Capacity
Input
EER
Capacity
Input
COP
Type / Quantity
Brand
3 4 5
Notes:
1. Cooling capacity test condition:
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Heating capacity test condition:
Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 20°C DB / 15°C WB;
3. Specifications are subject to change without prior notice for product improvement.
4. * Nominal ton only for reference.
5. Cooling or heating capacity as per specifications.
Tropical (T3) application, cooling only, 380~415V 3Ph~ 50Hz
5RT 8.5RT6.2RT & 7.5RT
Model
ESP
Nominal ton*
Cooling
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h 59,000
Two-way air out-in Two-way air out-in
89,000
Type
17.0 26.0
5.6 9.2
10.5 9.7
51,200 74,500
15.0 21.8
6.7 9.9
7.6 7.5
1,800 3,000
50 60
18.0 25.6
Scroll / 1 Scroll / 1
Copeland Danfoss
Centrifugal / Direct
Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centrifugal / Belt
8.1 12.0
MRBT-60CWN1-R MRBT-075CWN1-R
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
1,920×840×1,068 1,630×1,068×1,065
1,955×870×1,085 1,700×1,110×1,155
230/234 315/335
18°C~52°C 18°C~52°C
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type / Quantity
Brand
5
75,000
Two-way air out-in
22.0
7.7
9.7
62,700
18.4
8.6
7.3
2,600
60
20.1
Scroll / 1
Danfoss
Centrifugal / Direct
Axial / Direct
KJR-12B/dP(T)-E
10.4
MRBT-062CWN1-R
1,630×1,068×1,065
1,700×1,110×1,155
315/335
18°C~52°C
6.2 7.5
Two-way air out-in
103,000
30.0
10.4
9.8
85,600
25.1
11.4
7.5
3,600
75
26.3
Scroll / 1
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes YesYes Yes
Centrifugal / Belt
13.6
MRBT-085CWN1-R
2,165×1,002×1,335
2,220×1,040×1,415
445/458
18°C~52°C
8.5
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Specifications are subject to change without prior notice for product improvement.
3. * Nominal ton only for reference.
4. Cooling or heating capacity as per specifications.
Clim
aMas
ter S
erie
s
Clim
aMas
ter S
erie
s
-
23 24
Speci�cationsT1 application, heat pump, 380~415V 3Ph~ 50Hz
Model
ESP
Nominal ton*
Cooling
Heating
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Centralized controller
Net / Gross
Packing (W×H×D)
Side-discharge Side-discharge Side-discharge
36,000 48,000 58,000
10.55 14.07 17.29
3.05 4.79 5.64
11.8 10.0 10.3
37,500 51,500 62,500
10.99 15.09 18.32
3.00 4.56 5.21
12.5 11.3 12.0
1,500 1,858 2,045
50 50 50
4.25 6.05 7.05
6.4 8.8 10.9
Scroll / 1 Scroll / 1 Scroll / 1
Copeland Copeland Copeland
Centrifugal / Direct
Axial / Direct Axial / Direct Axial / Direct
- - -
Centrifugal / Direct Centrifugal / Direct
MRC-36HWN1-R MRC-48HWN1-R MRC-60HWN1-R
Type
Btu/h
kW
Btu/h.W
CFM
Pa
1,116×830×744
No No No
1,116×830×744 1,116×830×744
1,152×855×765 1,152×855×765 1,152×855×765
139/142 146/149 159/162
21°C~43°C 21°C~43°C 21°C~43°C
mm
mm
kg
kW
Btu/h
kW
Btu/h.W
kW
kW
A
Capacity
Input
EER
Capacity
Input
COP
Type / Quantity
Brand
3 4 5
Notes:
1. Cooling capacity test condition:
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Heating capacity test condition:
Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 20°C DB / 15°C WB;
3. Specifications are subject to change without prior notice for product improvement.
4. * Nominal ton only for reference.
5. Cooling or heating capacity as per specifications.
Tropical (T3) application, cooling only, 380~415V 3Ph~ 50Hz
5RT 8.5RT6.2RT & 7.5RT
Model
ESP
Nominal ton*
Cooling
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h 59,000
Two-way air out-in Two-way air out-in
89,000
Type
17.0 26.0
5.6 9.2
10.5 9.7
51,200 74,500
15.0 21.8
6.7 9.9
7.6 7.5
1,800 3,000
50 60
18.0 25.6
Scroll / 1 Scroll / 1
Copeland Danfoss
Centrifugal / Direct
Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centrifugal / Belt
8.1 12.0
MRBT-60CWN1-R MRBT-075CWN1-R
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
1,920×840×1,068 1,630×1,068×1,065
1,955×870×1,085 1,700×1,110×1,155
230/234 315/335
18°C~52°C 18°C~52°C
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type / Quantity
Brand
5
75,000
Two-way air out-in
22.0
7.7
9.7
62,700
18.4
8.6
7.3
2,600
60
20.1
Scroll / 1
Danfoss
Centrifugal / Direct
Axial / Direct
KJR-12B/dP(T)-E
10.4
MRBT-062CWN1-R
1,630×1,068×1,065
1,700×1,110×1,155
315/335
18°C~52°C
6.2 7.5
Two-way air out-in
103,000
30.0
10.4
9.8
85,600
25.1
11.4
7.5
3,600
75
26.3
Scroll / 1
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes YesYes Yes
Centrifugal / Belt
13.6
MRBT-085CWN1-R
2,165×1,002×1,335
2,220×1,040×1,415
445/458
18°C~52°C
8.5
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Specifications are subject to change without prior notice for product improvement.
3. * Nominal ton only for reference.
4. Cooling or heating capacity as per specifications.
Clim
aMas
ter S
erie
s
Clim
aMas
ter S
erie
s
-
25 26
Tropical (T3) application, cooling only, 380~415V 3Ph~ 50Hz
10RT 15RT12.5RT
Model
ESP
Nominal ton*
Cooling
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h 120,000
Two-way air out-in Two-way air out-in
150,000
Type
35.0 43.0
11.8 15.3
10.2 9.8
100,000 125,600
29.3 34.2
13.1 16.8
7.6 7.5
3,800 5,600
75 90
30.0 41.6
Scroll / 1 Scroll / 2
Danfoss Copeland
Centrifugal / Direct
Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centrifugal / Belt
16.0 20.0
MRBT-100CWN1-R MRBT-125CWN1-R
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
2,165×1,002×1,335 2,229×1,245×1,400
2,220×1,040×1,415 2,265×1,280×1,455
445/458 520/535
18°C~52°C 18°C~52°C
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type / Quantity
Brand
10 12.5
Two-way air out-in
180,000
53.0
18.0
10.0
159,600
46.7
21.3
7.5
6,600
90
53.0
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes
Centrifugal / Belt
27.0
MRBT-150CWN1-R
2,229×1,245×1,825
2,236×1,280×1,855
710/730
18°C~52°C
15
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Specifications are subject to change without prior notice for product improvement.
3. * Nominal ton only for reference.
4. Cooling or heating capacity as per specifications.
Tropical (T3) application, cooling only, 380~415V 3Ph~ 50Hz
17.5RT 30RT20RT
Model
ESP
Nominal ton*
Cooling
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h 210,000
Two-way air out-in Two-way air out-in
240,000
Type
60.0 70.0
20.0 23.6
10.5 10.2
180,600 213,000
52.9 62.4
23.5 27.7
7.7 7.7
7,300 8,400
90 100
57.8 66.0
Scroll / 2 Scroll / 2
Danfoss Danfoss
Centrifugal / Direct
Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centrifugal / Belt
29.0 36.0
MRBT-175CWN1-R MRBT-200CWN1-R
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
2,229×1,245×1,825 2,753×1,245×2,157
2,236×1,280×1,855 2,760×1,280×2,175
730/750 925/940
18°C~52°C 18°C~52°C
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type / Quantity
Brand
17.5 20
Side-discharge
358,300
105.0
35.8
10.0
328,600
96.0
43.8
7.5
13,400
250
92.0
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes Yes Customized
Centrifugal / Belt
49.0
MRCT-300CWN1-R
2,753×1,674×2,157
2,755×1,690×2,180
1,110/1,130
18°C~52°C
30
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Specifications are subject to change without prior notice for product improvement.
3. * Nominal ton only for reference.
4. Cooling or heating capacity as per specifications.
Clim
aMas
ter S
erie
s
Clim
aMas
ter S
erie
s
-
25 26
Tropical (T3) application, cooling only, 380~415V 3Ph~ 50Hz
10RT 15RT12.5RT
Model
ESP
Nominal ton*
Cooling
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h 120,000
Two-way air out-in Two-way air out-in
150,000
Type
35.0 43.0
11.8 15.3
10.2 9.8
100,000 125,600
29.3 34.2
13.1 16.8
7.6 7.5
3,800 5,600
75 90
30.0 41.6
Scroll / 1 Scroll / 2
Danfoss Copeland
Centrifugal / Direct
Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centrifugal / Belt
16.0 20.0
MRBT-100CWN1-R MRBT-125CWN1-R
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
2,165×1,002×1,335 2,229×1,245×1,400
2,220×1,040×1,415 2,265×1,280×1,455
445/458 520/535
18°C~52°C 18°C~52°C
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type / Quantity
Brand
10 12.5
Two-way air out-in
180,000
53.0
18.0
10.0
159,600
46.7
21.3
7.5
6,600
90
53.0
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes
Centrifugal / Belt
27.0
MRBT-150CWN1-R
2,229×1,245×1,825
2,236×1,280×1,855
710/730
18°C~52°C
15
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Specifications are subject to change without prior notice for product improvement.
3. * Nominal ton only for reference.
4. Cooling or heating capacity as per specifications.
Tropical (T3) application, cooling only, 380~415V 3Ph~ 50Hz
17.5RT 30RT20RT
Model
ESP
Nominal ton*
Cooling
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Capacity (1)Btu/h 210,000
Two-way air out-in Two-way air out-in
240,000
Type
60.0 70.0
20.0 23.6
10.5 10.2
180,600 213,000
52.9 62.4
23.5 27.7
7.7 7.7
7,300 8,400
90 100
57.8 66.0
Scroll / 2 Scroll / 2
Danfoss Danfoss
Centrifugal / Direct
Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centrifugal / Belt
29.0 36.0
MRBT-175CWN1-R MRBT-200CWN1-R
kW
Btu/h.W
kW
Btu/h
kW
Btu/h.W
CFM
Pa
2,229×1,245×1,825 2,753×1,245×2,157
2,236×1,280×1,855 2,760×1,280×2,175
730/750 925/940
18°C~52°C 18°C~52°C
mm
mm
kg
kW
kW
A
Input (1)
EER (1)
Capacity (2)
Input (2)
EER (2)
Type / Quantity
Brand
17.5 20
Side-discharge
358,300
105.0
35.8
10.0
328,600
96.0
43.8
7.5
13,400
250
92.0
Scroll / 2
Danfoss
Axial / Direct
KJR-12B/dP(T)-E
Centralized controller Yes Yes Customized
Centrifugal / Belt
49.0
MRCT-300CWN1-R
2,753×1,674×2,157
2,755×1,690×2,180
1,110/1,130
18°C~52°C
30
Notes:
1. Cooling capacity test condition (1):
Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2):
Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Specifications are subject to change without prior notice for product improvement.
3. * Nominal ton only for reference.
4. Cooling or heating capacity as per specifications.
Clim
aMas
ter S
erie
s
Clim
aMas
ter S
erie
s
-
27 28
Tropical (T3) application, heat pump, 380~415V 3Ph~ 50Hz
Model
ESP
Nominal ton*
Heating
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Two-way air out-in Two-way air out-in Two-way air out-in
75,000 89,000 103,000
22.0 26.0 30.0
7.7 9.2 10.4
9.7 9.7 9.8
89,000 102,000 120,000
26.0 30.0 35.0
7.6 8.8 10.1
11.7 11.6 11.8
2,600 3,000 3,600
60 60 75
10.4 12.0 13.6
21.0 25.6 27.5
Scroll / 1 Scroll / 1 Scroll / 1
Danfoss Danfoss Danfoss
Centrifugal / Belt
Axial / Direct Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes
Centrifugal / Belt Centrifugal / Belt
MRBT-062HWN1-R MRBT-075HWN1-R MRBT-085HWN1-R
Type
Btu/h
kW
Btu/h.W
CFM
Pa
1,630×1,068×1,065 1,630×1,068×1,065 2,165×1,002×1,335
1,700×1,110×1,155 1,700×1,110×1,155 2,220×1,040×1,415
320/340 320/340 450/463
-5°C~52°C -5°C~52°C -5°C~52°C
mm
mm
kg
kW
Btu/h
kW
Btu/h.W
kW
kW
A
Capacity (1)
Input (1)
EER (1)Cooling
62,700 74,500 85,600
18.4 21.8 25.1
8.6 9.9 11.4
7.3 7.5 7.5
Btu/h
kW
Btu/h.W
kW
Capacity (2)
Input (2)
EER (2)
Capacity
Input
COP
Type / Quantity
Brand
6.2 7.5 8.5
Notes:
1. Cooling capacity test condition (1): Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2): Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Heating capacity test condition: Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 20°C DB / 15°C WB;
3. Specifications are subject to change without prior notice for product improvement.
4. * Nominal ton only for reference.
5. Cooling or heating capacity as per specifications.
6.2RT & 7.5RT 8.5RT
Tropical (T3) application, heat pump, 380~415V 3Ph~ 50Hz
Model
ESP
Nominal ton*
Heating
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Two-way air out-in Two-way air out-in Two-way air out-in
120,000 150,000 180,000
35.0 43.0 53.0
11.8 15.3 18.6
10.2 9.8 9.7
126,000 167,000 191,000
37.0 49.0 56.0
10.9 14.2 17.5
11.6 11.8 10.9
3,800 5,600 6,600
75 90 90
16.0 21.0 27.0
31.0 41.8 54.7
Scroll / 1 Scroll / 2 Scroll / 2
Danfoss Copeland Danfoss
Centrifugal / Belt
Axial / Direct Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes
Centrifugal / Belt Centrifugal / Belt
MRBT-100HWN1-R MRBT-125HWN1-R MRBT-150HWN1-R
Type
Btu/h
kW
Btu/h.W
CFM
Pa
2,165×1,002×1,335 2,230×1,245×1,400 2,229×1,245×1,825
2,220×1,040×1,415 2,265×1,280×1,455 2,236×1,280×1,855
450/463 550/565 730/750
-5°C~52°C -5°C~52°C -5°C~52°C
mm
mm
kg
kW
Btu/h
kW
Btu/h.W
kW
kW
A
Capacity (1)
Input (1)
EER (1)Cooling
100,000 125,600 159,600
29.3 34.2 46.7
13.1 16.8 21.3
7.6 7.5 7.5
Btu/h
kW
Btu/h.W
kW
Capacity (2)
Input (2)
EER (2)
Capacity
Input
COP
Type / Quantity
Brand
10 12.5 15
Notes:
1. Cooling capacity test condition (1): Outdoor ambient temperature: 35°C, indoor temperature 26.7°C DB / 19.4°C WB;
Cooling capacity test condition (2): Outdoor ambient temperature: 46.1°C, indoor temperature 26.7°C DB / 19.4°C WB;
2. Heating capacity test condition: Outdoor ambient temperature: 7°C DB / 6°C WB, indoor temperature 20°C DB / 15°C WB;
3. Specifications are subject to change without prior notice for product improvement.
4. * Nominal ton only for reference.
5. Cooling or heating capacity as per specifications.
10RT 15RT12.5RT
Clim
aMas
ter S
erie
s
Clim
aMas
ter S
erie
s
-
27 28
Tropical (T3) application, heat pump, 380~415V 3Ph~ 50Hz
Model
ESP
Nominal ton*
Heating
Air flow Indoor side
Max. power input
Max. current
Compressor
Indoor fan Type / Drive type
Outdoor fan Type / Drive type
DimensionNet (W×H×D)
Weight
Ambient temperature
Wired controller
Net / Gross
Packing (W×H×D)
Two-way air out-in Two-way air out-in Two-way air out-in
75,000 89,000 103,000
22.0 26.0 30.0
7.7 9.2 10.4
9.7 9.7 9.8
89,000 102,000 120,000
26.0 30.0 35.0
7.6 8.8 10.1
11.7 11.6 11.8
2,600 3,000 3,600
60 60 75
10.4 12.0 13.6
21.0 25.6 27.5
Scroll / 1 Scroll / 1 Scroll / 1
Danfoss Danfoss Danfoss
Centrifugal / Belt
Axial / Direct Axial / Direct Axial / Direct
KJR-12B/dP(T)-E KJR-12B/dP(T)-E KJR-12B/dP(T)-E
Centralized controller Yes Yes Yes
Centrifugal / Belt Centrifugal / Belt
MRBT-062HWN1-R MRBT-075HWN1-R MRBT-085HWN1-R
Type
Btu/h
kW
Btu/h.W
CFM
Pa
1,630×1,068×1,065 1,630×1,068×1,065 2,165×1,002×1,335
1,700×1,110×1,155 1,700×1,110×1,155 2,