Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w...
Transcript of Comfort - geoservices.ca · mor-09hdn1-bn10w mor-12hdn1-bn10w moc-18hdn1-mn10w mof-22hdn1-mn10w...
INVERTER
Comfortat it’s best!
DUCTLESS AIR CONDITIONING OR HEAT PUMP SYSTEM
DUCTLESS AIR CONDITIONERS AND HEAT PUMPS
INVERTER
Compact and quiet outdoor unit
• Easy-to-use infra-red remote control unit
• Quiet, three-speed fans
• Louver position memory function
• Auto pivot air sweep
• Reusable, washable filters for quick and easy maintenance
• Anti-cycling protection for compressor
• R410A refrigerant meets industry standards and protects environment
• Digital display on unit ensures optimal operation
• Compact indoor unit of only 26.75 in. for 9,000 Btu/h
• PTC Heat cable prevents ice from accumulating in outdoor unit
Comfort-relatedfeatures:
Remote CONTROL UNIT
The unit can be installed high on the wall, while allowing user to enjoy full remote control. Louvers permit excellent air circulation, even in confined locations.
MODE : Auto – Cool – *Heat Dry – Fan. Cycles through the diffrent modes at each press of the button.
SWING : Adjusts the angle of the louvers to direct the air wheer you want it.
AIR DIRECTION : Sets the direction of blown air
FAN SPEED : Chooses the fan speed in 4 steps; Auto, Low, Medium, High.
TIMER ON : Sets the start time of the AC in increments of 30 minutes.
TIMER OFF : Sets the stop time of the AC in increments of 30 minutes.
TURBO : Allows the fan to operate at high speed to reach the set temperature faster.
LED DISPLAY : Allows to display or not the information in the display window.
SLEEP MODE:Adjusts the temperature and maintains it for 5 hours before shutting down
Mode Selection : Auto – Cool – *Heat
Dry - Fan
Louver direction setting
Louver direction setting
Fan speed selection
Start time selection
Stop time selection
Turbo mode
LED Display mode
Model MS11DContemporary indoor unit
MEMORIZED LOUVER POSITION
OAIR CONDITIONER COOLS UP TO 0 COHEAT PUMP HEATS UP TO -15 C
REFRIGERANT LEAK DETECTION
* Heat Pump Only
- Turbo Mode: This function will heat or cool a room to the desired temperature more rapidly.
- Cold Catalyst Filter: Eliminates VOCs (Volatile Organic Compounds) and other harmful gases as well as odors.
- Bidirectional Ventilation: In cooling mode, the cold air will be blowing horizontally while in heat mode, the warm air will be directed vertically. This technology makes the room temperature more comfortable and consistent.
- PTC Heat Strap: The PTC heat strap prevents the accumulation of snow and ice at the base of the outdoor unit.
- Low Ambient Kit: The air conditioner equipped with the low ambient kit can be used even if the outdoor temperature is as low as -0°C.
- Energy saving Protection: When the outdoor temperature reaches -15°C, the unit will turn off by itself to save energy.
- Sleep Mode: This function enables the air conditioner to automatically increase or reduce the temperature by 1°C every hour for 2 hours and hold steady for the next 5 hours before shutting down.
- Auto-restart: If the unit shuts down unexpectedly due to power outage, it will restart with the previous function setting automatically when the power returns.
- Refrigerant Leakage Detect: Indoor unit will display error code EC and automatically stop when refrigerant leakage is detected to protect compressor from overheating.
EACH DIRECT AIR
MINI-SPLIT HEAT PUMP SYSTEM COMES WITH THESE STANDARD FEATURES:
5yearson compressoron compressoron compressor 5years
on partson partson parts
- Easy installation
- Attractive
- Only 3” wall
opening integrates
seamlessly
into existing decor
- Ideal for condos
5yearson compressoron compressoron compressor 5years
on partson partson parts
5yearson laboron laboron labor
Limited
Warranty
Comfort like you like it
Limited
Warranty
SPECIFICATIONS AIR CONDITIONERS
Model
Cooling Capacity (Btu/h)
SEER
Humidity Removal (L/h)
Air Flow H-M-L (CFM)
Noise H-M-L (Db)
Width (mm/in)
Height (mm/in)
Depth (mm/in)
Weight (Kg/lb)
Outdoor Unit
Voltage
Breaker Amp
Noise (Db)
Width (mm/in)
Height (mm/in)
Depth (mm/in)
Weight (Kg/lbs)
MS11D-09CRDN1-BN10W MS11D-12CRDN1-BN10W MS11D-18CRDN1-MN10W MS11D-22CRDN1-MN10W
2 250 / 9 900 2 600 / 13 200 5 300 / 20 000 6 500 / 24 200
15,0 15,0 15,0 15,0
1,0 1,2 1,8 2,4
282/247/188 341/294/ 236 441/388/282 736/677/559
39/35/28 39/35/29 42/39/31 47/45/39
680 / 26,75 770 / 30,31 905 / 35,63 1030 / 40,55
255 / 10,04 255 / 10,4 275 / 10,83 315 / 12,40
178 / 7,01 188 / 7,40 198 / 7,8 218 / 8,58
7 / 15,4 7,5 / 16,5 9 / 19,8 12 / 26,4
MOR-09CDN1-BN10W MOR-12CDN1-BN10W MOC-18CDN1-MN10W MOF-22CDN1-MN10W
115V/1Ph/60HZ 115V/1Ph/60HZ 208-230V/1Ph/60HZ 208-230V/1Ph/60HZ
20A 20A 15A 20A
54 55 59 59
660 / 26 660 / 26 760 / 29,92 845 / 33,27
540 / 21,3 540 / 21,3 590 / 23,23 700 / 27,56
265 / 10,4 265 / 10,4 285 / 11,22 320 / 12,6
27 / 59,4 28 / 61,6 35 / 77 45 / 99
SPECIFICATIONS HEAT PUMPS
Model
Cooling Capacity Min/Max (Btu/h)
Heating Capacity Min/Max (Btu/h)
SEER
EER
HSPF Region 4
HSPF Region 5 Canada
Humidity Removal (L/h)
Indoor Unit
Air Flow H-M-L (CFM)
Noise H-M-L (Db)
Width(mm/in)
Height(mm/in)
Depth(mm/in)
Weight (Kg/lbs)
Outdoor Unit Model
Voltage
Breaker Amp
Noise (Db)
Width(mm/in)
Height(mm/in)
Depth(mm/in)
Weight (Kg/lbs)
MS11D-09HRDN1-BN10W MS11D-12HRDN1-BN10W MS11D-18HRDN1-MN10W MS11D-22HRDN1-MN10W
2 250 / 9 900 2 600 / 13 200 5 300 / 20 000 6 500 / 24 200
2 300 / 11 000 2 800 / 13 000 5 500 / 23 000 6 500 / 26 000
15,0 15,0 15,0 15,0
9,0 9,0 9,0 9,0
8,2 8,2 8,2 8,2
7,2 7,2 7,2 7,2
1,0 1,2 1,8 2,5
295 / 242 / 212 354 / 313 / 236 443 / 389 / 283 738 / 679 / 561
38/31/29 39/35/31 42/39/31 49/45/39
680 / 26.75 770 / 30.3 905 / 35.6 1 030 / 40.55
255 / 10.0 255 / 10.0 275 / 10.8 315 / 12.4
178 / 7.0 188 / 7.4 198 / 7.8 218 / 8.6
7 / 15 7,5 / 16,5 9 / 20 12 / 26,5
MOR-09HDN1-BN10W MOR-12HDN1-BN10W MOC-18HDN1-MN10W MOF-22HDN1-MN10W
115V 1Ph/60HZ 115V 1Ph/60HZ 208-230V 1Ph/60HZ 208-230V 1Ph/60HZ
15 15 20 25
56 57 59 60
660 / 26 660 / 26 760 / 30.0 845 / 33.25
540 / 21.25 540 / 21.25 590 / 23.25 700 / 27.55
265 / 10.4 265 / 10.4 285 / 11.25 320 / 12.6
27 / 59 30 / 66 37,5 / 83 47 / 103
Retailer
Directairhvac.com
To find your nearest Direct Air dealer, please contact the Powrmatic branch of your area.
Montréal9500, boul. Ray-LawsonAnjou, Qc, H1J 1L1Tel.: 514.493.6400Fax: [email protected]
Québec385, FortinVille-Vanier, Qc, G1M 1B2Tel.: 418.683.2708Fax: [email protected]
Ottawa162, Elm StreetOttawa, On, K1R 6N5Tel.: 613.230.7160Fax: [email protected]
Toronto111; Staffern DriveConcord, On, L4K 2R2Tel.: 905.660.0033Fax: [email protected]
London1064, Hargrieve RoadLondon, On, N6E 1P5Tel.: 519.675.1491Fax: [email protected]
Halifax100, Wright Ave.Dartmouth, NS, B3B 1L2Tel.: 902.454.8684Fax: 902:[email protected]
326ANG-0314
WARRANTYWARRANTYWARRANTY
LIMITEDLIMITEDLIMITED
THE MS11D SERIES OF AIR CONDITIONERS
have a 5 year limited warranty on the compressor and 5 years on parts
THE MS11D SERIES OF HEAT PUMPS
have a 5 year limited warranty on the compressor, 5 years on parts and 5 years on labour
DIRECTAIRHVAC.COM