2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431 COLLECTION AND PUMPING STATIONS BULLETIN P-624_J JULY 2018 FOR COLLECTION AND TRANSFER OF: MODEL CPS 56 Alternating duplex pumps with starters MODEL CPS 115 with optional suction strainer Collection and Pumping Stations utilize industrial duty corrosion resistant Series, 'EO' and 'EH' vertical pumps. Units are offered in a variety of capacities and all feature bearing-free pumps as standard. They offer the most economical and reliable means of collecting and transferring corrosive or hazardous wastes that need to be held for batch transfer and are not allowed to go down municipal drains. The systems are conveniently packaged to fit under most lab sinks, into photoprocessing systems or alongside production machines. Pump suction extension empties tank to within ½" of the tank bottom. When optional suction strainer is used, the minimum level is 4" above the tank bottom. Collection and Pumping Station can also serve as a re- placement sump to existing leaking or otherwise inadequate sump pit. If installed in an existing pit/tank, it would provide double containment. WASTE TREATMENT ACID NEUTRALIZATION / PLATING RINSE PHOTOGRAPHIC & LABORATORY SOLUTIONS CHEMICAL STORAGE Flows to 120 U. S. GPM or 71 ft. TDH @ 60 Hz (380 l/m or 15m @ 50 Hz) Corrosion resistant CPVC pump and HDPE tank for most acid/waste solutions to 140°F (60°C). (See a chemical resistance chart) Automatic, self-contained units offer unattended operation Compact and ready-to-use simply make connections and plug in; models available to fit under counter tops Maintenance-free vertical pump can run dry seal-less, no bearings, cantilever shaft Duplex systems with high level alarm and electronic alternator Custom systems (Consult Sales Dept.) Self-priming horizontal centrifugal pumps Larger sizes available Filter chamber on pump discharge pH and ORP controllers for pH and redox adjustment

Transcript of COLLECTION AND PUMPING STATIONS · 2018-07-02 · Collection and Pumping Stations utilize...

2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431

COLLECTION AND PUMPING STATIONSBULLETINP-624_J JULY 2018

FOR COLLECTION AND TRANSFER OF:

MODEL CPS 56Alternating duplex pumps with starters

MODEL CPS 115 with optional suction strainer

Collection and Pumping Stations utilize industrial duty corrosion resistant Series, 'EO' and 'EH' vertical pumps. Units are offered in a variety of capacities and all feature bearing-free pumps as standard. They offer the most economical and reliable means of collecting and transferring corrosive or hazardous wastes that need to be held for batch transfer and are not allowed to go down municipal drains. The systems are conveniently packaged to fit under most lab sinks, into photoprocessing systems or alongside production machines. Pump suction extension empties tank to within ½" of the tank bottom. When optional suction strainer is used, the minimum level is 4" above the tank bottom.

Collection and Pumping Station can also serve as a re-placement sump to existing leaking or otherwise inadequate sump pit. If installed in an existing pit/tank, it would provide double containment.

WASTE TREATMENT ACID NEUTRALIZATION / PLATING RINSE

PHOTOGRAPHIC & LABORATORY SOLUTIONSCHEMICAL STORAGE

• Flows to 120 U. S. GPM or 71 ft. TDH @ 60 Hz(380 l/m or 15m @ 50 Hz)

• Corrosion resistant CPVC pump and HDPE tankfor most acid/waste solutions to 140°F (60°C).

(See a chemical resistance chart)

• Automatic, self-contained unitsoffer unattended operation

• Compact and ready-to-usesimply make connections and plug in; models available to fit under counter tops

• Maintenance-free vertical pump can run dryseal-less, no bearings, cantilever shaft

• Duplex systems with high level alarm andelectronic alternator

• Custom systems (Consult Sales Dept.)• Self-priming horizontal centrifugal pumps

• Larger sizes available

• Filter chamber on pump discharge

• pH and ORP controllers for pH and redoxadjustment

COLLECTION AND PUMPING STATIONS2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431

P-624_J Page 2

12.512.518.518.518.524.524.524.530.524.536.530.548.548.5

13.519.516.519.519.525.519.525.519.531.525.531.531.537.5

A

12.512.512.512.518.512.518.518.524.524.524.530.524.536.5

317317317317470317470470622622622775622927

1016131616

21.215.221.215.227.221.227.227.233.2

254406330406406538386538386691538691691843

B C

343495419495495648495648495800648800800952

317317470470470622622622775622927775

12321232

D

in. mm in. in. mm in. mmmm

PUMPOUTLET EMOTOR

HP¾"

1¼"1¼"1½"1½"1½"

MNPT

1/8.3

.751.01.52.0

MAX. TDH

m@ 50 Hz

162236264290290310

mm

5.99.3

10.411.411.412.2

in.

3.97.28.9

10.915.014.0

CPS7CPS11CPS14CPS18CPS25CPS30CPS37CPS44CPS56CPS75CPS90CPS115CPS150CPS270

MODELTANKINLET

NPT1½"1½"1½"1½"1½"2"2"2"2"2"2"2"2"2"

U.S. gallons

L x W x HInches

TANK SIZE

2742536895114140166212284341435568

1021

12x12x1212x12x1812x18x1512x18x1818x18x1812x24x2418x24x1818x24x2424x30x1824x24x3024x36x2430x30x3024x48x3036x48x36

Liters

711141825303744567590115150270

2037507492

120

l/m@ 50 Hz

PUMPMODEL& FLOWCURVE

U.S. GPM@ 60 Hz

MAX. FLOW

EO2EO1EO3EO4EO5EH2

63120150240300380

Ft.@ 60 Hz

183442527165

Optional HL alarm

Pump On

Pump Off

D

1½" 1½"

Inlet

A

3"

1½"

8 ft.line cord

InletFNPT

C

1½" B

Pump & motorOutletMNPT E

DIMENSIONS & SPECIFICATIONS

COLLECTION AND PUMPING STATIONS2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431

P-624_J Page 3

Motors for EO4 pumps and smaller (1.0 HP) are single phase and are supplied with 8 ft. line cord with molded plug. Motors for EO5 pumps and larger are three phase. Level controls are state-of-the-art electronic conduc-tivity type with 316SS probes or float sensors for non-conductive solutions. The level control relay is mounted in a watertight (IP54) PVC enclosure which includes on/off switch with indicating light.

Pumps are constructed of CPVC, mounted on athick PVC tank cover (½", ¾" or 1", depending on model). PVC cover plate is bolted down to the tank with 304SS bolts. Pumps are independently mounted to the CPS cover via their own mounting plate. This allows for "drop in" service or replacement. Tanks are molded rigid HDPE, eliminating leakage. Tank is provided with 1½" or 2" NPT inlet fitting installed near top of side. Motors are chemical duty, TEFC and are rated continuous duty at either 50 Hz or 60 Hz.

CPS7–CPS11–CPS14–CPS18–CPS25–CPS30–CPS37–CPS44– CPS56–CPS75–CPS90–CPS115–CPS150–CPS270–

TO ORDER, use Price Code Number

EO2EO1EO3EO4

TANK PUMPHP

115V, 1φ1/8.3

.751.0

EO5EH2

HP230V, 3φ1.52.0

DESCRIPTION

SimplexDuplex - Non Alternating

Duplex Alternating

-S

-D

-A

CONFIGURATION

ConductivityFloat sensors

CF

DESCRIPTION

LEVEL CONTROL

Consult Sales Dept. for custom systems:Special tank materials and sizes, special connections,pump selections and additional add-on equipment not listed as optional.

GENERAL PRODUCT NOTES:1. CPS7 will use EO2 pump only.2. CPS11 will use EO2, EO1, and EO3 pumps only.3. 'EO5' and 'EH2' pumps available on sizes CPS56 and larger.4. Duplex configurations available on sizes CPS25 and larger.5. All 3-phase pumps and single phase pumps greater than 1.0 HP

require motor starters. (See optional equipment.)

Select tank size, pump, configuration and level control from the tables below. Combine selections to form the Model and Price Code Numbers. See optional equipment below.

EXAMPLE: TANK + PUMP + CONFIGURATION + LEVEL CONTROL = MODEL & PRICE CODE NO.CPS25- + EO1 + -D + C = CPS25-EO1-DC

MODEL & PRICE

CODE NO.

MODEL & PRICE

CODE NO.

MODEL & PRICE

CODE NO.

MODEL & PRICE

CODE NO.

MODEL & PRICE

CODE NO.

COLLECTION AND PUMPING STATIONS2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431

OPTIONAL

Select accessories individually to complete yourchemical collection, treatment or transfer system.

CUSTOMCHEMICALPUMPSTATION

Basketstrainer

solenoidvalve

PvC tank Cover

Controllers

level Control,float oreleCtronProBeaCtuated

HdPe tank

sumP PumPwitHsuCtionextension

P-624_J Page 4

CUSTOMIZED COLLECTION & PUMPING STATION

with filterchamber on

pump discharge

Specifications subject to change without notice. Registered trademark: Noryl - General ElectricF.O.B. Northbrook, Illinois

DISTRIBUTED BY

O-HV230

O-MS1S

O-MS3S

PRICE CODE NO.

39-1007C39-1002C39-2002C45-0162O-1378

O-1486

Suction strainer EO2 pump

EO1 & EO3 pumps EO4 & EO5 pumps

EH2 pumpHigh level alarm relay (For customer supplied sonic or visual device) Audible alarm (80 decibels) installed

DESCRIPTION PRICE CODE NO.

230 volt, single phase (in place of 115V standard)

Magnetic starter with H-O-A selector switch in watertight (IP54) PVC enclosure

- single phase (specify voltage)- 3 phase (specify voltage, will

change CPS to 3 phase motor)(1 starter req'd for each pump)

DESCRIPTION