5.1 CONFIGURE DOMAIN HAWK AGENT
Inthisstep, Domain Hawk agent is configured to use EMS server as itstransport and also
to communicatewith Hawk event service.
a) Open the /tra/domain//hawkagent.cfg file in a
text editor
b) Underems_transport property, specifythe EMS server connectiondetailsas,shownbelow.
-ems_transport tcp://:port #!encryptedpassword
c) In order to communicate with Hawk event service, add the ami_rvd_session
that matches with that of Hawk event services ami_rvd_session. (Steps to
configure the Hawk event service with the same parameters is mentioned in a
latersection)
Forexample,-ami_rvd_session 8500 127.0.0.1 tcp:8500
d) Save the changes.
Note: The encrypted password can be generated by running the Hawk utility
program tibhawkpassword locatedin yourhawk/bindirectory:
tibhawkpassword-encrypt password
where password is the current password
5.2 RENAME DEFAULT HAWK AGENT
In this step, Hawk agent that comes with standalone installation is renamed so that the
two Hawk agents (one that comes with standalone Hawk installation and another one
that comes with TIBCO Admindomain)can be distinguishedin the HawkDisplay.
a) Open the /hawk/bin/hawkagent.cfgfile in a text editor
b) Change the agent name as mentionedbelow.
-agent_name _default
c) Underthe ems_transport, specifythe EMS server connectiondetails
-ems_transport tcp://:port #!encryptedpassword
d) Save the changes.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
2/26
Page 1010 of
5.3 MONITOR AND MANAGE EMS SERVER FROM HAWK
To use TIBCO Hawk to manage the TIBCO Enterprise Message Service server, load the
HawkController or HawkListenerclasses provided into the TIBCO Hawk agent. Once the
classes are loaded, methods for managing the EMS server are available in the
TIBCO Hawk display. In this implementation, the HawkController classes have been
loaded.
Installing the classes is different for UNIX and Windowsplatforms. Given below are the
steps for installing the classes in UNIX. Please refer to Hawk documentation for
theprocedure on Windows.
a) Locate the tibjmsadmin.hma file in the TIBCO EMS installation directoryunder the /ems/samples/admin/hawk subdirectory and copy it toTIBCO TRA Hawkpluginsdirectory.
Usually, TIBCO TRA Hawk plugins directory is located in
/tra/domain//plugin
b) Locate tibjmsadmin.jar in the ems/clients/java subdirectory, and copy it intothe TIBCO TRA Hawkpluginsdirectory.
c) Open the /tra/domain//hawkagent.cfg file in a
text editor and specify the -hma_plugin_dir option to include the directory where
yourTIBCO Hawkpluginsare located.
-hma_plugin_dir"/tra/domain//plugin"
Save changes to hawkagent.cfg
d) Navigate to plugins directory and open the tibjmsadmin.hma file in a text
editor
e) Specify the TIBCO Hawkmicroagentclassyou wish to use in the
element. In this implementation,
com.tibco.tibjms.admin.hawk.HawkControllerhas been used.
f) Specify the username and password and serverURL to use to connect to the
TIBCO EMS server in the appropriate elements For example:
-useradmin
-passwordMyPassword
-servertcp://:
-
7/27/2019 Cognizant_configure Domain Hawk Agent
3/26
Page 1111 of
-timeout
-
7/27/2019 Cognizant_configure Domain Hawk Agent
4/26
Page 1212 of
5
You should use specify thepredefined admin useror a user that is a member of
the $admingroup.
Save changes to tibjmsadmin.hma.
Note: To use an encrypted password, specifyencryptedPassword instead of
-password. As the value for -encryptedPassword, supply the output you obtainby
running the Hawk utility program tibhawkpassword located in your hawk/bin
directory:
tibhawkpassword-encrypt password
where password is the current password
5.4 MONITORING EVENT SERVICE FROM HAWK
The TIBCO Hawk Event Service is a process that records TIBCO Hawkalertsand changes
in agent status. When communicationwith an agent is lost,the Event Servicecan invoke
a user-providedscript.Alertsand notificationscan be recorded to log files or a database.
Typically, the TIBCO Hawk Event Service is installed on a minimal number of computers
in the network.
Inthis step, Hawk event serviceis configured to use EMS server as its transport and also
to communicatewith Hawk agent service.
a) Open the /hawk/bin/hawkevent.cfgfile in a text editor
b) Underthe ems_transport, specifythe EMS server connectiondetails.
-ems_transport tcp://:port #!encryptedpassword
c) Also specify the TIBCO Rendezvous session used by the TIBCO Hawk event
service for AMI communications.
Forexample,
-ami_rvd_session 8500 127.0.0.1 tcp:8500
d) Save the changes.
5.5 RESTART HAWK SERVICES
Save all the above changes and restart the following servicesso that the changes will be
effective.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
5/26
Page 1313 of
a) Hawk agent servicethat comes with standalone installation
b) Domain Hawk agent service
c) Hawk event service
5.6 CONFIGURE HAWK DISPLAY FOR EMS TRANSPORT (ON WINDOWS)
Inthisparticularimplementation,Hawk Display runningon Windows is configured to use
EMS transport.
Open the Hawk Configuration window from menu and configurethe following.
a) Ensure that Hawk Domain name matches with that of domainname mentioned in
the Domain Hawkagentshawkagent.cfg
b) In the Transport tab, select the Primary Transport as EMS and provide the EMS
server connection details. This should be the same EMS server that was
configured in Step5.1
c) Click Ok
-
7/27/2019 Cognizant_configure Domain Hawk Agent
6/26
Page 1414 of
d) Click No on the dialogsthat askfor restartingthe Hawk relatedservices.
Now open the Hawk Display from menu to verify that all the changes are done
successfully.
6. RULEBASES
6.1 PRE-REQUISITES
The many new Hawk rulebases,command procedures, etc. need to be separate from the
core TIBCO and Hawk products. This will allow TIBCO Hawk to be upgraded
independently from the custom components and vice-versa. Given below are the pre-
requisites for the rulebases.
6.1.1 FOLDER STRUCTURE
Create the following folder structure under TIBCO domain root (i.e.
/tra/domain/)
----Accelerator
-flags (Location of .enabledand .running files)
-scripts(Location of custom command procedures)
6.1.2 COMMAND PROCEDURES
The BW and ADB Adapter rulebases use Command Procedures to perform some actions.
To track the status of BW process engine or ADB adapter .enabledand .running files will
be created and deletedin the flagsfolder,using these Command Procedures.
UNIX shell script files namely CreateEmptyFile.sh and RemoveFile.sh will be used
forcreating and deleting the appropriate files. If running on Windows the equivalent
batch scripts need to be prepared. At any point of time, Hawk rulebase will identify the
status of BW process engine or ADB adapter based on the availability of one orboth of
these
files and takes the necessary action.
CreateEmptyFile.sh RemoveFile.sh
Copy the CreateEmptyFile.sh and RemoveFile.sh scripts to tibco_root>/tra / domain/
/Accelerator/scripts folder.
Aftercopying the files, change the permissions of CreateEmptyFile.shand RemoveFile.sh
to 777 so that these can be invokedfrom the rulebases.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
7/26
Page 1515 of
6.1.3 VARIABLES CONFIGURATION FILE
TIBCO Hawk has the capability to use external variables within the Hawk rulebases.
There are some fields that will be used in all rulebases. Some of the fields will be
common, others will not. These include certain directory locations, log file locations,
and several e-mail relatedvalues.
The
/tra/domain//Accelerator/scripts/HawkAC_variables.dat will
hold all of the variables. All of the values will be configured for
each machine/environment in thisfile. Every agent can read only one configuration file.
Standard Variablesto include:
MAIL_SERVER: This is the mail server used for sendingemails.
MAIL_FROM: The email address defined in this variable will be used as fromaddress on any email sent from Hawk
MAIL_CC: Any email recipient defined in this variable will be CCed on any Hawkalertsent.
MAIL_SUBJECT:The prefix used in the subject of email is definedin thisvariable.
MAIL_TO: Any email recipient defined in this variable will be emailed on anyemail sent from Hawk.
DOMAIN_NAME: This shouldbe set to the name of the TIBCO Administrationdomain
CONFIG_ROOT: This is the location of all of the scripts and config files for Hawk.The variablesfile shouldalreadybe set to the correctvalue.
FLAG_ROOT: This is the location of the Hawkenableflags. The variables fileshouldalreadybe set to the correctvalue.
TRA_ROOT: This is the root location of the TIBCO domain.The variablesfile shouldalreadybe set to the correctvalue.
Note: Apart from above variables, rulebase specific variables also can be
added. Please keep in mind that if any changes are done in the
HawkAC_variables.dat, Domain Hawk agent serviceneed to be restarted to make the
changes effective. The recommendation would be to add the variables for all
rulebases at once, to avoid restartingthe Hawk agent service for several times.
The HawkAC_variable.dat file need to be placed in the / tra/domain/
/Accelerator/scriptsdirectory
HawkAC_variable.da
t
-
7/27/2019 Cognizant_configure Domain Hawk Agent
8/26
Page 1616 of
The TRA hawkagent.cfg configuration file must be modified to include the variables
file. The variables line must be uncommented, and the name and location of
the variablesfile appended to theparameter.
-variables
/tra/domain//Accelerator/scripts/HawkAC_variable.dat
Save the changes.
RestartDomain Hawk agent service.
6.2 RULEBASE: BUSINESSWORKS PROCESS ENGINE
This section will discuss on the Hawk Rulebase to monitor and manage the
TIBCO BusinessWorks Process engines.
The naming convention followed for this kind of rulebase is BWEngine-
Deployment- Component.hrb. Here Deployment is the Enterprise Archive name and
Component is theprocess archivename in the BWproject.
6.2.1 REQUIREMENTS
If the engine is started or stopped from the TIBCO Administrator, then Hawk
rulebase should not start the engine. If the engine is stopped abruptly due to
some reason, then the rulebaseshouldattempt to start the engine for once.
Ateach step, appropriatealertsand/oremailsshouldbe sent from the rulebase.
6.2.2 IMPLEMENTATION DETAILS
Given below are the implementation details for CISCommon BW process engine. The
rulebasename is "BWEngine-CISCommon-CISCommonProcesses.hrb"
BWEngine-CISComm
on-CISCommonProces
Given below is the sequence diagram which describes the high level implementation of
thisrulebase.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
9/26
Page 1717 of
FIGURE 2 BW PROCESS ENGINE RULEBASE FLOW
-
7/27/2019 Cognizant_configure Domain Hawk Agent
10/26
Page 1818 of
The rules include:
Check for the .running file: This rule will test to see the CISCommon-
CISCommonProcesses.running file exists in flags directory. If the file exists,
then the no_error post condition is set. Ifthe file does not exist,then the error
post condition is set. The rule will checkfor the .runningfile every 2 seconds. This
post condition is used later in the rulebase to help Hawk determine if the
BW Process Engine has successfullystartedpreviously.
Check for the .enabled file: This rule will test to see the CISCommon-
CISCommonProcesses.enabled file exists in flags directory. If the file exists,then the enabled post condition is set. If the file does not exist, then the
disabledpost condition is set. The rule will check for the .enabled file every 5
seconds. This post condition is used later in the rulebase to decide whetherthe
rulebaseneed to take some action or not
This rule checks to see if the BW Process Engine is running, also using the
TRA.getComponentStatus Hawk microagent. This test is performed every six
seconds. This rule has several steps depending on if the service is running. The
rulewill:
-
7/27/2019 Cognizant_configure Domain Hawk Agent
11/26
Page 1919 of
o Check to see if the BW Process Engine has a state of INITIALIZING. If it
does, the BW Process Engine isbeing started via the TIBCO Administrator.
The rule will run the CreateEmptyFile.sh script with
appropriate parameters such that CISCommon-
CISCommonProcesses.enabled file is created and there by enabledpost
conditionis set.
o Check to see if the BW Process Engine has a state of RUNNING. Ifit does,
the BW Process Engine has successfully started. The rule will send an
informational notification and email that it is running, and run the
CreateEmptyFile.sh script with appropriate parameters such thatCISCommon-CISCommonProcesses.running file is created and there by
no_errorpost conditionis set.
o Check to see if the BW Process Engine has a state of STOPPING and
enabled post condition exists. This signifies that BW Process Engine
isbeing stopped via TIBCO Administrator. The rule will run
the RemoveFile.sh script with appropriate parameters to remove the
CISCommon-CISCommonProcesses.enabled file to ensure that disabled
post condition is set. This will prevent Hawk from attemptingto restart the
BW Process Engine.
o Check to see if the BW Process Engine has a state of STOPPED. Thissignifies that BW Process Engine is no longer running. It couldbe stopped
via TIBCO Administrator or due to some error. The rule will run the
RemoveFile.sh script with appropriate parameters to remove the
CISCommon-CISCommonProcesses.running file to ensure that error
post conditionis set.
o Check to see if the BW Process Engine has a state of STOPPED and
enabledpost condition is set. This signifies that BW Process Engine got
-
7/27/2019 Cognizant_configure Domain Hawk Agent
12/26
Page 2020 of
terminated abruptly due to some error. The rule will send a low alert
stating the BW Process Engine is not running, and will attempt to start the
engine. The rule will also run RemoveFile.sh script with appropriate
parameters to remove the CISCommon-CISCommonProcesses.running
file to ensure that error post condition is set. After90 seconds, ifthe BW
process is not started, a highalert will be sent stating that the BW Process
Engine is still down. The BW Process Engine will be disabledto prevent the
rule from attempting to start it again. The rule will also run
the RemoveFile.sh script with appropriate parameters to remove the
CISCommon-CISCommonProcesses.enabled file to ensure that disabled
post condition is set, preventing Hawk from attempting to restart the BW
Process Engine.
o Check to see if the BW Process Engine has a state of STOPPED and
disabled post condition is set. The rule will send a low alert that the
Hawkrulebase will not attempt to start the BW Process Engine.
6.2.3 LOAD THE RULEBASE
Before sending the rulebase (from the rulebase editor) to the selected machine,please
keep in mindthe following items.
This rulebaseneed to be appliedonly afterverifying that a BW Process Enginehas been started successfullyonce in TIBCO Administrator.
Apply the rulebase only when the BW process engine is down. After applyingthe rulebasestart the BW Process Engine from TIBCO Administrator.
Before redeploying a new Enterprise Archive for a BW process engine that isbeing monitoredby this rulebase,please STOP the BW Process engine manually
in TIBCO Administratorand ensure that it is not running. Ifthe BWprocess engine
is not stopped before redeployment, the engine will get killed and the rulebase
will try to start the engineagain.
6.2.4 MIGRATION ACROSS ENVIRONMENTS
Since this rulebase depends on the variables defined in HawkAC_variables.dat,
please ensure that the values for these variables are correctly defined as perthe
respectiveenvironmentconfiguration.
Same rulebase can be moved from one environment to another environment
withoutany changes.
6.2.5 TEMPLATE RULEBASE
Given below is the template rulebase that has been implemented with the requirements
mentionedin section6.2.1
-
7/27/2019 Cognizant_configure Domain Hawk Agent
13/26
Page 2020 of
BWEngine-Deployme
ntName-ComponentIn
Following changes have to be done,prior to using thisrulebase for a BW Process Engine.
DeploymentName need to be replaced with the EAR name defined in the BW
Project
ComponentInstanceNameneed to be replacedwith Process Archivename defined
under the EAR.
AuthorName need to be replacedwith the author of the rulebase HostName(IPAddress) need to be replacedwith a correspondingvalue
DateTime need to be replacedwith the current date time BWEngineDesc needs to be replaced with appropriate description of the BW
Process Engine.
Finally, the rulebase file name need to be changed with actual values ofDeploymentNameand ComponentInstanceName
6.3 RULEBASE: FILE ADAPTER
This section will discuss on the HawkRulebase to monitor and manage the TIBCO File
Adapter.
The naming convention followed for this kind of rulebase is FileAdapter-
Deployment- Component.hrb. Here Deployment is the Enterprise Archive name and
Componentis the File Adapterarchivename in the BWproject.
6.3.1 REQUIREMENTS
If the File Adapter is started or stopped from the TIBCO Administrator, then the
Hawk rulebase should send alerts and email notifications. If the File adapter
is stopped abruptly due to some reason, then also the rulebase should send
alerts and emails.
6.3.2 IMPLEMENTATION DETAILS
Given below are the implementation details for a Payment File Adapter. The rulebase
name is "FileAdapter-Finance-FinancePaymentFileAdapter.hrb"
-
7/27/2019 Cognizant_configure Domain Hawk Agent
14/26
Page 2121 of
FileAdapter-Finance-
FinancePaymentFileA
The rulewill:
Check for the existence of the Payment File Adaptermicroagent. Ifthe numberof
microagents becomes zero, sends a high alert along with an email
mentioning that Payment File Adapter is down. If the number of the
microagents becomes one, a notification and email will be sent saying that
Payment File Adapter is up and running.The rule will check the microagentcount
for every 5 seconds.
6.3.3 LOAD THE RULEBASE
This rulebasecan be sent to the machineat anypoint of time. Basedon the current state
of the File Adapter,an alertand email willbe sent.
6.3.4 MIGRATION ACROSS ENVIRONMENTS
Since this rulebase depends on the variables defined in HawkAC_variables.dat,
please ensure that the values for these variables are correctly defined as perthe
respectiveenvironmentconfiguration.
Same rulebase can be moved from one environment to another environment
withoutany changes.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
15/26
Page 2222 of
6.3.5 TEMPLATE RULEBASE
Given below is the template rulebase that has been implemented with the requirements
mentionedin section6.3.1
FileAdapter-Deploym
entName-Component
Following changes have to be done,prior to using thisrulebase for a FileAdapter.
DeploymentName need to be replaced with the EAR name defined in the BW
Project
ComponentI
nstanceName need to be replaced with FileA
dapterA
rchive namedefinedunder the EAR.
AuthorName need to be replacedwith the author of the rulebase HostName(IPAddress) need to be replacedwith a correspondingvalue DateTime need to be replacedwith the current date time FileAdpaterMicroagentNameproperty needs to be defined with appropriate value
in the HawkAC_variables.dat file. In general as there will be more than one file
adapter in the properties file, it is recommended to add a prefix to thisproperty
name.
FileAdapterDesc needs to be replaced with appropriate description of the file
adapter.
Finally, the rulebase file name need to be changed with actual values ofDeploymentNameand ComponentInstanceName
6.4 RULEBASE: ADB ADAPTER
This section will discuss on the HawkRulebase to monitor and manage the TIBCO ADB
Adapter.
The naming convention followed for this kind of rulebase is ADBAdapter-Deployment-
Component.hrb. HereDeploymentis the Enterprise Archive name and Component is the
ADB Adapterarchivename in the BWproject.
6.4.1 REQUIREMENTS
-
7/27/2019 Cognizant_configure Domain Hawk Agent
16/26
Page 2323 of
Ifthe ADB Adapter is started or stopped from the TIBCO Administrator, then Hawk
rulebase shouldnot start the adapter. Ifthe ADB Adapter is stopped abruptlydue
to some reason, then the rulebaseshouldattempt to start the adapterfor once.
Ateach step, appropriatealertsand/oremailsshouldbe sent from the rulebase.
6.4.2 IMPLEMENTATION DETAILS
The implementation details for a LIMS ADB Adapter are similar to that of BW Process
Engine defined in section 6.2.2. The rulebase name is "ADBAdapter-WaterQuality-
LIMS.hrb"
ADBAdapter-WaterQ
uality-LIMS.hrb
6.4.3 LOAD THE RULEBASE
Loadingrulesare same as that of BW Process Engine definedin section6.2.3
6.4.4 MIGRATION ACROSS ENVIRONMENTS
Migrationrulesare same as that of BW Process Engine definedin section 6.2.4
6.4.5 TEMPLATE RULEBASE
Given below is the template rulebase that has been implemented with the requirements
mentionedin section6.4.1
ADBAdapter-Deploy
mentName-Componen
Following changes have to be done,prior to using thisrulebase for an ADB adapter.
DeploymentName need to be replaced with the EAR name defined in the BW
Project
ComponentInstanceName need to be replaced with ADB Adapter Archive namedefinedunder the EAR.
AuthorName need to be replacedwith the author of the rulebase HostName(IPAddress) need to be replacedwith a correspondingvalue DateTime need to be replacedwith the current date time
-
7/27/2019 Cognizant_configure Domain Hawk Agent
17/26
Page 2424 of
ADBAdapterDesc needs to be replaced with appropriate description of the ADBadapter.
Finally, the rulebase file name need to be changed with actual values ofDeploymentNameand ComponentInstanceName
6.5 RULEBASE: EMS SERVER
This section will discuss on the HawkRulebase to monitor and manage the TIBCO EMS
server.
The namingconventionfollowed for thisrulebaseis EMSServer-Status.hrb.
6.5.1 REQUIREMENTS
Ifthe EMS server is not running, rulebase should send an alert and email and try
starting the EMS server. If the EMS server could not be started successfully then
an appropriatealertand email shouldbe sent.
Ifthe EMS server is up and running,a notificationand email shouldbe sent.
6.5.2 IMPLEMENTATION DETAILS
Given below are the implementation details for an EMS server. The rulebase name is
"EMSServer-Status.hrb"
EMSServer-Status.hr
b
For every 10 seconds, the rule will check whether the EMS server is running or not.
If the EMS server is not running, a low alert and email will be sent and rulebase
will attempt to start the EMS server. If the EMS server is brought back successfully
then notification and email will be sent. Ifthe EMS server couldnot be brought back, an
alert and email willbe sent.
6.5.3 LOAD THE RULEBASE
This rulebasecan be sent to the machineat anypoint of time. Basedon the current state
of the EMS server, alert and email will be sent. In case the EMS server is not running,
rulebase will attempt to start it.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
18/26
Page 2525 of
6.5.4 MIGRATION ACROSS ENVIRONMENTS
Since this rulebase depends on the variables defined in HawkAC_variables.dat,
please ensure that the values for these variables are correctly defined as perthe
respectiveenvironmentconfiguration.
Same rulebase can be moved from one environment to another environment
withoutany changes.
6.6 RULEBASE: EMS QUEUESThis section will discuss on the HawkRulebase to monitor and manage the TIBCO EMS
queues.
The naming convention followed for this rulebase is EMSQueueTopic-Deployment.hrb.
HereDeploymentis the EnterpriseArchivename.
6.6.1 REQUIREMENTS
For a queue, if the pending message count exceeds the limit (even though the
corresponding BW Process Engine is up and running) an alert and email should be
sent. Here the limit is defined based on the message load and the monitoring
interval.
At any point of time, if the pending message count exceeded the limit an alert
and email shouldbe sent. This check need to be repeated for every subsequent
one hour and up to 12 hrs.
6.6.2 IMPLEMENTATION DETAILS
Given below are the implementation details for an EMS queue in Contact project. The
rulebasename is "EMSQueueTopic-Contact.hrb"
EMSQueueTopic-Con
tact.hrb
The rulewill:
-
7/27/2019 Cognizant_configure Domain Hawk Agent
19/26
Page 2626 of
Check for the .enabled file: This rule will test to see the Contact-
ContactProcess.enabled file exists in flags directory. If the file exists, then the
enabledpost condition is set. If the file does not exist, then the not_enabled
post conditionis set. The rule will checkfor the .enabledfile every 5 seconds. This
post condition is used later in the rulebase to decide whether the rulebase need
to take some action or not.
Check for the .running file: This rule will test to see the Contact-
ContactProcess.running file exists in flags directory. If the file exists, then
runningpost condition is set. If the file does not exist, then the not_running
post condition is set. The rule will checkfor the .runningfile every 4 seconds. This
post conditionis used laterin the rulebase.
Get the pending message count: This rulegets the queueproperties for every 60
seconds. Itverifieswhether thepending message count is greater than 1 and BW
Process Engine is running (both enabled and running post conditions exist). Ifthis
condition is satisfiedthen an alertand email willbe sent statingthat there are
n
pending messages in the queue. Once the condition is satisfied then for every
subsequent one hour (and up to 12 hrs) this checkwill be performed and if the
conditionexistsat that instance of timean alertand email willbe sent.
6.6.3 LOAD THE RULEBASE
This rulebase can be sent to the machine at anypoint of time. It will check the current
state of the queue, and accordinglyan alertand email willbe sent.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
20/26
Page 2727 of
6.6.4 MIGRATION ACROSS ENVIRONMENTS
Since this rulebase depends on the variables defined in HawkAC_variables.dat,
please ensure that the values for these variables are correctly defined as per
the respectiveenvironmentconfiguration.
Same rulebasecan be moved from one environment to anotherenvironment without
any changes.
6.6.5 TEMPLATE RULEBASE
Given below is the template rulebase that has been implemented with the requirements
mentionedin section6.6.1
EMSQueueTopic-Depl
oymentName(Q).hrb
Following changes have to be done, prior to using this rulebase for monitoring an EMS
queue.
DeploymentName need to be replaced with the EAR name defined in the
corresponding BW Project
ComponentInstanceNameneed to be replacedwith Process Archivename defined
under the EAR.
AuthorName need to be replacedwith the author of the rulebase HostName(IPAddress) need to be replacedwith a correspondingvalue DateTime need to be replacedwith the current date time QueueNameproperty needs to be defined with appropriate value of queue name
in the HawkAC_variables.dat file. In general as there will be more than one
queue in the properties file, it is recommended to add a prefix to thisproperty
name.
ProcessNameproperty needs to be defined with appropriate value of BW process
name in the HawkAC_variables.dat file. In general as there will be more than
one process name in the properties file, it is recommended to add a prefix to this
property name.
ProjectNameproperty needs to be defined with appropriate value of BW project
name in the HawkAC_variables.dat file. In general as there will be more than
one project name in the properties file, it is recommended to add aprefix to this
property name.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
21/26
Page 2828 of
MaxPendingMessages is the maximum number of messages in the queue and if
the messages exceed this limit an alert and email will be sent. This needs to be
replacedwith appropriatenumber based on the requirement.
Finally, the rulebase file name need to be changed with actual value ofDeploymentName
6.7 RULEBASE: EMS DURABLE TOPICS
This section will discuss on the HawkRulebase to monitor and manage the TIBCO EMS
durabletopics.
The naming convention followed for this rulebase is EMSQueueTopic-Deployment.hrb.
HereDeploymentis the EnterpriseArchivename.
6.7.1 REQUIREMENTS
For a durable topic, ifthependingmessage count exceeds the limit (even though
the corresponding BW Process Engine is up and running) an alert and email
should be sent. Here the limit is defined based on the message load and the
monitoring interval.
At any point of time, if the pending message count exceeded the limit an alert
and email shouldbe sent. This check need to be repeated for every subsequent
one hour and up to 12 hrs.
Also if the durable count for this topic does not match with the expected durable
count, an alert and email shouldbe sent. This check need to be repeated forevery subsequent one hour and up to 12 hrs.
6.7.2 IMPLEMENTATION DETAILS
Given below are the implementationdetails for an EMS durabletopic in WAAproject.The
rulebasename is "EMSQueueTopic-WAA.hrb"
EMSQueueTopic-WA
A.hrb
The rulewill:
-
7/27/2019 Cognizant_configure Domain Hawk Agent
22/26
Page 2929 of
Check for the .enabled file: This rule will test to see the WAA-WAA.enabled file
exists in flags directory. If the file exists, then the enabledpost condition is
set. If the file does not exist, then the not_enabledpost condition is set. The
rule will check for the .enabled file every 5 seconds. This post condition is used
later in the rulebase to decide whether the rulebase need to take some action ornot.
Check for the .running file: This rule will test to see the WAA-WAA.running file
exists in flags directory. Ifthe file exists, then runningpost condition is set. If
the file does not exist, then the not_runningpost condition is set. The rule will
checkfor the .runningfile every 4 seconds. This post condition is used later in the
rulebase.
This rule checks for the pending message count and the durable count for this
topic.This test is performed every 30 seconds. The rulewill:
-
7/27/2019 Cognizant_configure Domain Hawk Agent
23/26
Page 3030 of
o Get the durable count: This test verifies whether the durable count is
equal to 2 or not. Ifthe durable count is not equal to 2, an alert and email
will be sent. Once the condition is satisfied then for every subsequent one
hour (and up to 12 hrs) this checkwill be performed and if the condition
existsat that instance of timean alertand email willbe sent.
o Get the pending message count: This test verifies whether the pending
message count is greater than 5 and the BW Process Engine is running
(both enabled and running post conditions exist). If this condition is
satisfied then an alert and email will be sent stating that there are
npending messages in the queue. Once the condition is satisfied then
for every subsequent one hour (and up to 12 hrs) this check will be
performed and if the condition exists at that instance of time an alert
and email willbe sent.
6.7.3 LOAD THE RUL
EBA
SE
This rulebase can be sent to the machine at anypoint of time. It will check the current
state of the topic,and accordinglyan alertand email willbe sent.
6.7.4 MIGRATION ACROSS ENVIRONMENTS
-
7/27/2019 Cognizant_configure Domain Hawk Agent
24/26
Page 3131 of
Since this rulebase depends on the variables defined in HawkAC_variables.dat,
please ensure that the values for these variables are correctly defined as per
the respectiveenvironmentconfiguration.
Same rulebasecan be moved from one environment to anotherenvironment without
any changes.
6.7.5 TEMPLATE RULEBASE
Given below is the template rulebase that has been implemented with the requirements
mentionedin section6.7.1
EMSQueueTopic-Depl
oymentName(T).hrb
Following changes have to be done, prior to using this rulebase for monitoring an EMSdurabletopic.
DeploymentName need to be replaced with the EAR name defined in the
corresponding BW Project
ComponentInstanceNameneed to be replacedwith Process Archivename defined
under the EAR.
AuthorName need to be replacedwith the author of the rulebase HostName(IPAddress) need to be replacedwith a correspondingvalue DateTime need to be replacedwith the current date time TopicNameproperty needs to be defined with appropriate value of topic name in
the HawkAC_variables.dat file. Ingeneral as there will be more than one queue
in the propertiesfile, it is recommended to add aprefix to thisproperty name.
ProcessNameproperty needs to be defined with appropriate value of BW process
name in the HawkAC_variables.dat file. In general as there will be more than
one process name in the properties file, it is recommended to add a prefix to this
property name.
P
rojectNameproperty needs to be defined with appropriate value of BW projectname in the HawkAC_variables.dat file. In general as there will be more than
one project name in the properties file, it is recommended to add aprefix to this
property name.
DurSubCount is the durable subscriber count for this topic. If the durable count
doesnt match with this number then an alert and email will be sent. This needs
to be replacedwith appropriatenumber based on the requirement.
-
7/27/2019 Cognizant_configure Domain Hawk Agent
25/26
Page 3232 of
MaxPendingMessages is the maximum number of messages in the queue and if
the messages exceed this limit an alert and email will be sent. This needs to be
replacedwith appropriatenumber based on the requirement.
Finally, the rulebasefile name need to be changed with actualDeploymentName
6.8 RULEBASE: CLIENT CONNECTIONS TO THE EMS SERVER
This section will discuss on the HawkRulebase to monitor the unauthorized client
connectionsestablishedto TIBCO EMS server.
The naming convention followed for this rulebase is EMSServer-
UnauthorizedConnections.hrb.
6.8.1 REQUIREMENTS
This rulebaseshouldmonitorthe connectionsestablishedto the EMS server and if
a connection has been established from a unknown machine (that is not part of
the allowablemachines),an alertand email shouldbe sent.
The list of allowable machines shouldbe prepared in advance as this list should
be includedin the rulebase.
Note: This rulebase will not prevent the connection from an unauthorized
machine to the EMS server, but will generate alert and email when
such connectionis established.
6.8.2 IMPLEMENTATION DETAILS
Given below are the implementation details for monitoring the unauthorized client
connections to EMS server. The rulebase name is "EMSServer-
UnauthorizedConnections.hrb"
EMSServer-Unauthor
izedConnections.hrb
The rule will get the list of EMS server connections for every 60 seconds and verifies the
host name of the machines that are connected. If there is at least one machine that is
not in the list of allowablemachines,then an alertand email willbe sent.
6.8.3 LOAD THE RULEBASE
-
7/27/2019 Cognizant_configure Domain Hawk Agent
26/26