codigo de diagnostico 2121-7

download codigo de diagnostico 2121-7

of 3

Transcript of codigo de diagnostico 2121-7

  • 8/9/2019 codigo de diagnostico 2121-7

    1/3

    Shutdown SIS

    Previous Screen

    Product: TRACK-TYPE TRACTOR

    Model: D8T TRACK-TYPE TRACTOR KPZ

    Configuration: D8T TRACK-TYPE TRACTOR KPZ00001-UP (MACHINE) POWERED BY C15 Engine

    TroubleshootingD8T, D9T, D10T and D11T Track-Type Tractors

    Media Number -RENR8056-08 Publication Date -01/07/2011 Date Updated -19/07/2011

    i03213972

    MID 113 - CID 2121 - FMI 07

    SMCS - 1435-038-FWD

    Conditions Which Generate This Code:

    Página 1 de 3(SEBP3654 - ) - Service Information System

    11/12/2014https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si...

  • 8/9/2019 codigo de diagnostico 2121-7

    2/3

    Illustration 1 g01640476

    Schematic of the Forward Switch

    This diagnostic code is recorded when status of the direction switch is wrong. When the switch is in

    REVERSE, the Normally Open circuit is grounded and the Normally Closed circuit is open. When theswitch is in FORWARD or NEUTRAL, the Normally Open circuit is open and the Normally Closed

    circuit is grounded. A diagnostic code is recorded when the status of the direction switch does notmatch the signal from the position sensor (direction selector). There will be no backup system for the

     position sensor (direction selector) if the sensor fails.

    Test Step 1. CHECK THE DIRECTION SWITCH.

    A. Check the screws that hold the direction switch to the console. Tighten any loose screws.

    Página 2 de 3(SEBP3654 - ) - Service Information System

    11/12/2014https://127.0.0.1:444/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/si...

  • 8/9/2019 codigo de diagnostico 2121-7

    3/3

    B. If the problem persists, loosen the screws on the direction switch and rotate the switch slightly.

    C. Tighten the screws. Change the direction of the machine and then determine if the diagnosticcode is still present.

    D. If the problem still exists, loosen the screws on the direction switch. Rotate the switch in the

    opposite direction slightly.

    E. Tighten the screws. Change the direction of the machine and then determine if the diagnostic

    code is still present.

    F. Determine if the CID 2121 FMI 07 is present.

    Expected Result:

    The CID 2121 FMI 07 diagnostic code is present.

    Results:

    • OK - The CID 2121 FMI 07 diagnostic code is present.

    Repair: The problem has not been corrected. The direction switch may have failed. Replace the

    direction switch. Exit this procedure and perform the diagnostic code procedure again. If the problem persists, the ECM may have failed. Prior to replacing an ECM, always contact your

    dealership for possible consultation with Caterpillar. This consultation may greatly reduce

    repair time. See the Troubleshooting, "Electronic Control Module (ECM) - Replace".

    STOP

    • NOT OK - The CID 2121 FMI 07 diagnostic code is not present.

    Repair: The problem does not exist at this time. The initial problem was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and

    reconnected. Resume normal machine operation.

    STOP

    Copyright 1993 - 2014 Caterpillar Inc.

    All Rights Reserved.

    Private Network For SIS Licensees.

    Thu Dec 11 13:37:41 UTC-0430 2014

    Página 3 de 3(SEBP3654 - ) - Service Information System

    11/12/2014https://127 0 0 1:444/sisweb/sisweb/techdoc/techdoc print page jsp?returnurl=/sisweb/si