CodeReferenceCompetitiveComparison ProductSelectionGuide

w a t t s . c o m

Water Tempering Valves

LavSafe™

L111, MMV

1170, L1170

USG-B

Page 2: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

Table of Contents

PAGE

Code Reference Guide

InternationalPlumbingCode(IPC)-TemperingValves................. 2-3

InternationalResidentialCode(IRC)-TemperingValves............. 4-5

UniformPlumbingCode(UPC)-TemperingValves...................... 6-7

Product Selection Guide

forASSE1017,1069&1070...................................................... 8-9

forASSE1070......................................................................... 10-11

forASSE1017......................................................................... 12-13

Page 3: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

2 3

Watts Code Reference Guide

International Plumbing Code (IPC) - Tempering Valves

Application Watts Listed Products IPC - 2003 IPC - 2006 IPC - 2009

State Adoption By Series CT, KS, MO, NY, VT AR, AZ, CO, DC, FL, GA, ID, MI, MS, NC, ND, OH, SC, UT AL, DE, MD, NH, OK, PA, RI, UT, VA, WV

Public Lavatories USG-B, MMV, L111, LavSafe™ No reference to tempering valves or ASSE standards. 416.5 Tempered water for public hand-washing facilities. Tempered water shall be delivered from public hand-washing facilities through an approved water temperature limiting device that conforms to ASSE 1070.

416.5 Tempered water for public hand-washing facilities. Tempered water shall be delivered from public hand-washing facilities. Tempered water shall be delivered through an approved water temperature limiting device that con-forms to ASSE 1070 or CSA B125.

Bathtubs and Whirlpools MMV, L111 No reference to tempering valves or ASSE standards. 424.5 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120°F (49°C) by water temperature limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/shower valve in accordance with section 424.3.

424.5 Bathtub and whirlpool bathtub valves. The hot water supplied to bath-tubs and whirlpool bathtubs shall be limited to a maximum temperature of 120°F (49°C) by water temperature limiting device that conforms to ASSE 1070 or CSA B125.3 , except where such protection is otherwise provided by a com-bination tub/shower valve in accordance with section 424.3.

Shower and Tub-Shower E800SG, E800MSG (WBT) 424.3 Shower valves. Shower and tub-shower combination valves shall be balanced pressure, thermostatic or combination balanced-pressure/thermostatic valves that con-form to the requirements of ASSE 1016 or CSA B125.

424.3 Individual shower valves. Individual shower valves and tub-shower combinations valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016 or CSA B125 and shall be installed at the point-of-use. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be filed adjusted in accordance with the manufacturer's instructions. In-line ther-mostatic valves shall not be utilized for compliance with this section.

424.3 Individual shower valves. Individual shower valves and tub-shower combinations valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016 or CSA B125.1 and shall be installed at the point-of-use. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be filed adjusted in accordance with the manufacturer's instructions. In-line thermostatic valves shall not be utilized for compliance with this section.

Gang Showers MMV, L111 424.3 Shower valves (cont'd). Multiple (gang) showers supplied with a single tempered water supply pipe shall have the water supply for such showers controlled by a master thermostatic mixing valve complying with ASSE 1017. Shower and tub-shower combi-nation valves and master thermostatic mixing valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer's instructions.

424.4 Multiple (gang) showers. Multiple (gang) showers supplied with a single-tempered water supply pipe shall have the water supply for such showers con-trolled by an approved automatic temperature control mixing valves that con-forms to ASSE 1069 or CSA B125, or each shower head shall be individually con-trolled by a balanced-pressure/thermostatic valve that conforms to ASSE 1016 or CSA B125 and is installed at the point-of-use. Such valves shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer's instructions.

424.4 Multiple (gang) showers. Multiple (gang) showers supplied with a sin-gle-tempered water supply pipe shall have the water supply for such showers controlled by an approved automatic temperature control mixing valves that conforms to ASSE 1069 or CSA B125, or each shower head shall be individu-ally controlled by a balanced-pressure/thermostatic valve that conforms to ASSE 1016 or CSA B125 and is installed at the point-of-use. Such valves shall be equipped with a means to limit the maximum setting of the valve to 120°F (49°C), which shall be field adjusted in accordance with the manufacturer's instructions.

Temperature-Actuated Flow Reduction

WHT115 424.5 Temperature-actuated, flow reduction valves for individual fixture fittings. Temperature-actuated, flow reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used alone as a substi-tute for the balanced pressure, thermostatic or combination shower valves required in Section 424.3.

424.7 Temperature-actuated, flow reduction valves for individual fixture fittings. Temperature-actuated, flow reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used alone as a substitute for the balanced pressure, thermostatic or combination shower valves required in Section 424.3.

424.7 Temperature-actuated, flow reduction valves for individual fixture fittings. Temperature-actuated, flow reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used alone as a substitute for the balanced pressure, thermostatic or combi-nation shower valves required in Section 424.3.

Bidet MMV, L111

No reference to tempering valves or ASSE standards. 408.3 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110°F (43°C) by a water tem-perature limiting device conforming to ASSE 1070.

408.3 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110°F (43°C) by a water temperature limiting device conforming to ASSE 1070.

Water Heater 1170, MMV, N170-M3 501.2 Water heater as space heater. Where a combination potable water heating and space heating system requires water for space heating at temperatures higher than 140°F (60°C), a master thermostatic mixing valve complying with ASSE 1017 shall be provided to limit the water supplied to the potable hot water distribution system to a temperature of 140°F (60°C) or less. The potability of the water shall be maintained throughout the system.

501.2 Water heater as space heater. Where a combination potable water heat-ing and space heating system requires water for space heating at temperatures higher than 140°F (60°C), a master thermostatic mixing valve complying with ASSE 1017 shall be provided to limit the water supplied to the potable hot water distribution system to a temperature of 140°F (60°C) or less. The potability of the water shall be maintained throughout the system.

501.2 Water heater as space heater. Where a combination potable water heating and space heating system requires water for space heating at temperatures higher than 140°F (60°C), a master thermostatic mixing valve complying with ASSE 1017 shall be provided to limit the water supplied to the potable hot water distribution system to a temperature of 140°F (60°C) or less. The potability of the water shall be maintained throughout the system.

Tankless Heaters 1170, MMV, N170-M3 501.6 Water temperature control in piping from tankless heaters. The temperature of water from tankless water heaters shall be a maximum of 140°F (60°C) when intended for domestic uses. This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3.

501.6 Water temperature control in piping from tankless heaters. The tempera-ture of water from tankless water heaters shall be a maximum of 140°F (60°C) when intended for domestic use This provision shall not supersede the require-ment for protective shower valves in accordance with Section 424.3.

501.6 Water temperature control in piping from tankless heaters. The tem-perature of water from tankless water heaters shall be a maximum of 140°F (60°C) when intended for domestic use. This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3.

Temperature-Actuated Mixing Valves

1170, MMV, N170-M3

613.1 Temperature-actuated mixing valves. Temperature-actuated mixing valves, which are installed to reduce water temperatures to defined limits, shall comply with ASSE 1017.

613.1 Temperature-actuated mixing valves. Temperature-actuated mixing valves which are installed to reduce water temperatures to defined limits, shall comply with ASSE 1017.

613.1 Temperature-actuated mixing valves. Temperature-actuated mixing valves which are installed to reduce water temperatures to defined limits, shall comply with ASSE 1017.

Hot Water Supply System 1170, MMV, N170-M3 607.1 Where required. In nonresidential occupancies, hot water or tempered water shall be supplied for bathing and washing purposes. Tempered water shall be delivered from accessible hand-washing facilities.

607.1 Where required. In nonresidential occupancies, tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water to a maximum of 110°F (43°C). This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3.

607.1 Where required. In nonresidential occupancies, hot water shall be sup-plied for culinary purposes, cleansing, laundry or building maintenance pur-poses. Tempered water shall be supplied through a water temperature limiting device that conforms to ASSE 1070 and shall limit the tempered water to a maximum of 110°F (43°C). This provision shall not supersede the requirement for protective shower valves in accordance with Section 424.3.

Page 4: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

4 5

Watts Code Reference Guide

International Residential Code (IRC) - Tempering Valves

Application Watts Listed Products IRC - 2003 IRC - 2006 IRC - 2009

State Adoption By Series CT, HI, IN, KS, MA, NY, VT AK, AR, DC, FL, GA, HI, ID, KY, LA, MI, MN, MS, MT, ND, NJ, NV, OH, OR, SC, WY CA, IA, MD, ME, NH, OK, PA, RI, TN, UT, VA, WA, WV

Bathtubs and Whirlpools MMV, L111 P2713 Bathtubs and P2720 Whirlpool Tubs (tempering not addressed) P2713.3 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120°F (49°C) by a water temperature-limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/shower valve in accordance with Section P2708.3.

P2713.3 Bathtub and whirlpool bathtub valves. The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120°F (49°C) by a water temperature-limiting device that conforms to ASSE 1070, except where such protection is otherwise provided by a combination tub/shower valve in accordance with Section P2708.3.

Shower and Tub-Shower E800SG, E800MSG (WBT) P2708.3 Shower control valves. Shower and tub/shower combination valves shall be equipped with control valves of the pressure balance, thermostatic mixing or combina-tion pressure balance/thermostatic mixing valve types with a high limit stop in accor-dance with ASSE 1016 or CSA B125. The high limit stop shall be set to limit water tem-perature to a maximum of 120°F (49°C).

P2708.3 Shower control valves. Shower and tub/shower combination valves shall be equipped with control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with a high limit stop in accordance with ASSE 1016 or CSA B125. The high limit stop shall be set to limit water temperature to a maximum of 120°F (49°C). In-line thermostatic valves shall not be used for compliance with this section.

P2708.3 Shower control valves. Shower and tub/shower combination valves shall be equipped with control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with a high limit stop in accordance with ASSE 1016 or CSA B125. The high limit stop shall be set to limit water temperature to a maximum of 120°F (49°C). In-line thermostatic valves shall not be used for compliance with this section.

Bidet MMV, L111 P2721 Bidet Installations (tempering not addressed) P2721.2 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110°F (43°C) by a water temperature-limiting device that conforms to ASSE 1070.

P2721.2 Bidet water temperature. The discharge water temperature from a bidet fitting shall be limited to a maximum temperature of 110°F (43°C) by a water temperature-limiting device that conforms to ASSE 1070.

Water Heater 1170, MMV, N170-M3 P2802.2 Temperature control. Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140°F (60°C), a master ther-mostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of 140°F (60°C) or less for domestic uses. P2802.3 Scald Protection. Where a combination water heater-space heating system requires water for space heating at temperatures exceeding 140°F (60°C), a means such as a mixing valve shall be installed to temper water for domestic uses.

P2802.2 Temperature control. Where a combination water heater-space heat-ing system requires water for space heating at temperatures exceeding 140°F (60°C), a master thermostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of 140°F (60°C) or less for domes-tic uses.

P2802.2 Temperature control. Where a combination water heater-space heat-ing system requires water for space heating at temperatures exceeding 140°F (60°C), a master thermostatic mixing valve complying with ASSE 1017 shall be installed to temper the water to a temperature of 140°F (60°C) or less for domestic uses.

Page 5: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

6 7

Watts Code Reference Guide

Uniform Plumbing Code (UPC) - Tempering Valves

Application Watts Listed Products UPC - 2003 UPC - 2006 UPC - 2009

State Adoption By Series AK, ID, NV, SD CA, HI, MT, NM, OR, Houston, Topeka IA, WA, St. Louis (CA, ID, MT to adopt 2009)

Public Lavatories USG-B, MMV, L111, LavSafe™ 414.1 Limitation of Hot Water Temperature for Public Lavatories. Hot water deliv-ered for public-use lavatories shall be limited to a maximum temperature of 120°F (49°C). The water heater thermostat shall not be considered a control for meeting this provision.

413.1 Limitation of Hot Water Temperature for Public Lavatories. Hot water delivered for public-use lavatories shall be limited to a maximum temperature of 120°F (49°C). The water heater thermostat shall not be considered a control for meeting this provision.

413.1 Limitation of Hot Water Temperature for Public Lavatories. Hot water delivered for public-use lavatories shall be limited to a maximum temperature of 120°F (49°C) by a device that conforms to ASSE 1070 or CSAB125.3. The water heater thermostat shall not be considered a control for meeting this provision.

Bathtubs and Whirlpools MMV, L111 415.0 Whirlpool Bathtubs (tempering not addressed). 421.0 Limitation of Hot Water in Bathtubs. The maximum hot water temperature discharging from the bathtub filler shall be 120°F (49°C).

414.5 Limitations of Hot Water in Bathtubs and Whirlpool Bathtubs. The maxi-mum hot water temperature discharging from the bathtub and whirlpool bath-tub filler shall be limited to 120°F (49°C). The water heater thermostat shall not be considered a control for meeting this provision.

414.5 Limitations of Hot Water in Bathtubs and Whirlpool Bathtubs. The maxi-mum hot water temperature discharging from the bathtub and whirlpool bathtub filler shall be limited to 120°F (49°C) by a device that conforms to ASSE 1070 or CSA B125.3. The water heater thermostat shall not be considered a control for meeting this provision.

Shower and Tub-Shower E800SG, E800MSG (WBT) 420.0 Shower and Tub-Shower Combinations Showers and tub-shower com-binations in all buildings shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance / thermostatic mixing valve type that provide scald and thermal shock protection. These valves shall conform to ASSE 1016.

418.0 Shower and Tub-Shower Combination Control Valves. Showers and tub-shower combinations in all buildings shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance / thermostatic mixing valve type that provide scald and thermal shock protection. These valves shall conform to ASSE 1016.

418.0 Shower and Tub-Shower Combination Control Valves. Showers and tub-shower combinations in all buildings shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance / thermostatic mixing valve type that provide scald and thermal shock protection. These valves shall conform to ASSE 1016.

Gang Showers MMV, L111 420.0 (cont'd) ...Gang showers, when supplied with a single temperature-controlled water supply pipe, may be controlled by a master thermostatic mixing valve in lieu of individually controlled pressure balance, thermostatic, or combi-nation pressure balance/thermostatic mixing valves. Handle position stops shall be provided on such valves and shall be adjusted per the manufacturer's instruc-tions to deliver a maximum mixed water setting of 120°F (49°C). The water heater thermostat shall not be considered a suitable control for meeting this provision.

418.0 (cont'd) ...Gang showers, when supplied with a single temperature-con-trolled water supply pipe, may be controlled by a master thermostatic mixing valve in lieu of individually controlled pressure balance, thermostatic, or com-bination pressure balance/thermostatic mixing valves. Handle position stops shall be provided on such valves and shall be adjusted per the manufacturer's instructions to deliver a maximum mixed water setting of 120°F (49°C). The water heater thermostat shall not be considered a suitable control for meeting this provision.

418.0 (cont'd) ...Gang showers, when supplied with a single temperature-con-trolled water supply pipe, shall be controlled by a mixing valve that conforms to ASSE 1069. Handle position stops shall be provided on such valves and shall be adjusted per the manufacturer's instructions to deliver a maximum mixed water setting of 120°F (49°C). The water heater thermostat shall not be considered a suitable control for meeting this provision.

Bidet MMV, L111 417.0 Bidets (tempering not addressed) 416.0 (tempering not addressed). 416.3 Limitation of Water Temperature in Bidets. The maximum hot water tem-perature discharging from a bidet shall be limited to 110°F (43°C) by a device that conforms to ASSE 1070 or CSA B125.3.The water heater thermostat shall not be considered a suitable control for meeting this provision.

Water Heater 1170, MMV, N170-M3

505.4 Temperature-Limiting Devices. A water heater installation or hot water storage vessel installation shall be provided with over-temperature protection by means of an approved, listed device installed in accordance with the terms of its listing and the manufacturer's instructions.

505.5 Temperature-Limiting Devices. A water heater installation or hot water storage vessel installation shall be provided with over-temperature protection by means of an approved, listed device installed in accordance with the terms of its listing and the manufacturers instructions.

505.5 Temperature-Limiting Devices. A water heater installation or hot water storage vessel installation shall be provided with over-temperature protection by means of an approved, listed device installed in accordance with the terms of its listing and the manufacturers instructions.

Temperature Actuated Mixing Valves 1170, MMV, N170-M3 Table 14-1 Referenced Standards. ASSE 1017-1998 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced.

Hot Water Supply System 1170, MMV, N170-M3 Table 14-1 Referenced Standards. ASSE 1017-1998 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced. Table 14-1 Referenced Standards. ASSE 1017-2003 referenced.

Page 6: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

8 9

Product Selection Guide

Honeywell Zurn/Wilkins Conbraco/Apollo Reliance/Cash Acme Symmons Caleffi Leonard

Point-of-Use/Sourcefor ASSE 1017, 1069 & 1070

MMV AM-1 1070 ZW1070 34B - MVB Heatguard 160 Aqualine 5213 270, 370

ASSE Standard Listing 1017, 1069, 1070 1017, 1070 1070 1017, 1070 1069, 1070 1017, 1070 1070 1017, 1070

GPM @ 45 psid 1⁄2" 13 10 10 17 9 14 13 11

3⁄4" 13 10 10 17 10 14 13 12

1" 13 10 10 17 11 not available 13 not available

Minimum Stated Flow 0.5 gpm 0.5 gpm 0.5 gpm 1.0 gpm 1.0 gpm 0.5 gpm 1.0 gpm 0.5 gpm

Outlet Temperature Range 80 - 120°F 70 - 120°F 95 - 115°F 80 - 120°F 95 - 115°F 60 - 140°F 85 - 120°F not stated

Cold Water Inlet Temperature 39 - 85°F not stated 40 - 75°F 39 - 85°F 40 - 80°F 39 - 80°F 39 - 85°F not stated

Hot Water Inlet Temperature max. 200°F max. 212°F 120 - 195°F 120 - 180°F max. 195°F 120 - 180°F 120 - 185°F max. 200°F

Maximum Working Pressure 150 psi 150 psi 145 psi 150 psi 145 psi 150 psi 140 psi 125 psi

Approach Temperature (outlet maximum within ___°F of inlet HW supply)

5°F 3°F not stated 5°F not stated 10°F 9°F 5°F

Lockable Temperature Setting Yes Yes Yes Yes Yes Yes Yes

Standard Unions Order Separate Yes Yes Order Separate Yes Yes No

Standard Checks Order Separate Yes Yes Order Separate Yes Yes Yes

Lead Free* No Yes Yes No No Yes Yes

Standard Filters No No Yes Order Separate Yes No No

Connection Type Threaded Yes Yes Yes Yes Yes Yes Yes - MIPS

Sweat Yes Yes Yes Yes Yes Yes Yes

CPVC Yes Yes Yes Yes No NO No

PEX Yes Yes Yes Yes Yes No No

Quick Connect No No No Yes No No No

Competitive Data Taken From Manufacturer Sales Literature BAA/ARRA Compliant 22-Sep-10

*Thewettedsurfaceofthisproductcontactedbyconsumablewatercontainslessthanonequarterofonepercent(0.25%)ofleadbyweight.

Page 7: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

10 11

Product Selection Guide

Honeywell Zurn/Wilkins Conbraco/Apollo Reliance/Cash Acme Symmons Leonard

Point-of-Usefor ASSE 1070

USG-B LavSafe™ UMV ZW3870T 34D - MVD Heatguard 145 5-210-CK 170

ASSE Standard Listing 1070 1070 1070 1070 1070 1070 1017, 1070 1070

GPM @ 45 psid 2.5 gpm 2.2 gpm 3.0 gpm 3.0 gpm 3.5 gpm 4.5 gpm 5.0 gpm 4.5 gpm

Minimum Stated Flow 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm

Outlet Temperature Range 80 - 120°F 60 - 120°F 80 - 120°F 95 - 115°F 85 - 120°F 95 - 115°F 105 - 120°F not stated

Cold Water Inlet Temperature 39 - 80°F 39 - 80°F not stated 40 - 75°F not stated 39 - 80°F 39 - 80°F not stated

Hot Water Inlet Temperature 120 - 180°F 120 - 180°F max. 180°F 120 - 195°F max. 210°F max. 195°F 120 - 180°F max. 212°F

Maximum Working Pressure 150 psi 125 psi 150 psi 145 psi 125 psi 145 psi 125 psi 125 psi

Approach Temperature (outlet maximum within ___°F of inlet HW supply)

5°F 5°F 15°F not stated not stated not stated 10°F 5°F

Lead Free* No Yes Yes No No Yes

WaterSense n/a n/a n/a n/a n/a n/a n/a

Lockable Temperature Setting Yes Yes Yes Yes Yes Yes

Integrated 4-port Configuration w/Internal Cold Water Bypass

n/a No - Add on No No No No No - 4th optional

Standard Checks Yes Yes Yes Yes Yes Yes

Standard Filters No No No No Yes No - 4th optional

Connection Type 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression 3/8" Compression

Competitive Data Taken From Manufacturer Sales Literature BAA/ARRA Compliant BAA/ARRA Compliant 22-Sep-10

*Thewettedsurfaceofthisproductcontactedbyconsumablewatercontainslessthanonequarterofonepercent(0.25%)ofleadbyweight.

Page 8: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

12 13

Product Selection Guide

Honeywell Zurn/Wilkins Conbraco/Apollo Reliance/Cash Acme Symmons Caleffi Leonard

Point-of-Sourcefor ASSE 1017

1170, L1170 AM-1 ZW1017 34A - MVA 110-D 110-HX 115-D 115-H 5-120, 5-130, 5-140 Aqualine 521 270, 370

ASSE Standard Listing 1017 1017 1017 1017 1017 1017 1017, 1070 1017 1017, 1070

GPM @ 45 psid 1⁄2" 23 8 18 23 17 17 not available not available not stated 14 20 11

3⁄4" 23 12 18 23 18 18 28 28 not stated 14 20 12

1" 23 16 18 23 19 19 32 32 not stated not available 20 not available

Minimum Stated Flow 0.5 gpm 0.5 gpm 0.5 gpm 0.5 gpm 1.0 gpm 1.0 gpm 2.5 gpm 2.5 gpm not stated 0.5 gpm not stated 0.5 gpm

Outlet Temp. Range

Standard 90 - 160°F 100 - 145°F 80 - 165°F 130 - 180°F 95 - 120°F 95 - 176°F 95 - 120°F 95 - 140°F 85 - 160°F 60 - 140°F 85 - 150°F not stated

Low 60 - 120°F 60 - 100°F 95 - 131°F 85 - 140°F not stated

Cold Water Inlet Temperature 39 - 85°F not stated 40 - 75°F 39 - 80°F 39 - 80°F 39 - 80°F 40 - 80°F 40 - 80°F 40 - 80°F 39 - 85°F not stated max. 200°F

Hot Water Inlet Temperature max. 200°F max. 212°F 120 - 195°F max. 210°F max. 195°F 120 - 180°F 120 - 180°F max. 200°F 125 psi

Maximum Working Pressure 150 psi 150 psi 145 psi 150 psi 145 psi 125 psi 150 psi 200 psi 5°F

Approach Temperature (outlet maximum within ___°F of inlet HW supply)

5°F not stated not stated not stated not stated 10°F 10°F 27°F Yes

Lead Free* No Yes Yes No No No Yes Yes

Lockable Temperature Setting Yes Yes Yes Yes Yes Yes Yes No

Standard Unions Order Separate Yes Yes Order Separate No Yes Yes Yes

Standard Checks Order Separate Yes Yes Order Separate No Yes Yes No

Standard Filters No No Yes Order Separate No Yes No Yes - MIPS

Connection Type Threaded Yes Yes Yes Yes* Yes* Yes Yes Yes Yes Yes Yes

Sweat Yes Yes Yes Yes Yes Yes Yes No Yes Yes No

CPVC Yes Yes Yes Yes* Yes* Yes Yes No No No No

PEX Yes Yes Yes Yes Yes Yes Yes No Yes No No

Quick Connect No No No Yes* Yes* Yes Yes No No No No

Competitive Data Taken From Manufacturer Sales Literature BAA/ARRA Compliant *only available in 1/2 & 3/4 22-Sep-10

*Thewettedsurfaceofthisproductcontactedbyconsumablewatercontainslessthanonequarterofonepercent(0.25%)ofleadbyweight.

Page 9: Code Reference Competitive Comparison - Watts Watermedia.wattswater.com/F-ProdSelectionGuide.pdf · Code Reference Competitive Comparison Product Selection Guide w a t t s . c o m

Telephone E-mail

Headquarters: Watts Regulator Company 815 Chestnut St., North Andover, MA 01845-6098 U.S.A. 978 688-1811 [email protected]

Edwards, Platt & Deely, Inc. 277 Royal Ave., Hawthorne, NJ 07506 973 427-2898 [email protected] Edwards, Platt & Deely, Inc. 368 Wyandanch Ave., North Babylon, NY 11703 631 253-0600 [email protected] Vernon Bitzer Associates, Inc. 980 Thomas Drive, Warminster, PA 18974 215 443-7500 [email protected] W. P. Haney Company, Inc. 51 Norfolk Ave., South Easton, MA 02375 508 238-2030 [email protected]

Disney McLane & Associates 428 McGregor Ave., Cincinnati, OH 45206 800 542-1682 [email protected] J. B. O’Connor Company, Inc. P.O. Box 12927, Pittsburgh, PA 15241 724 745-5300 [email protected] RMI 2533 Mechanicsville Tpk., Richmond, VA 23223 804 643-7355 [email protected] The Joyce Agency, Inc. 8442 Alban Rd., Springfield, VA 22150 703 866-3111 [email protected] WMS Sales, Inc. (Main office) 9580 County Rd., Clarence Center, NY 14032 716 741-9575 [email protected]

Billingsley & Associates, Inc. 2728 Crestview Ave., Kenner, LA 70062-4829 504 602-8100 [email protected] Billingsley & Associates, Inc. 478 Cheyenne Lane, Madison, MS 39110 601 856-7565 [email protected] Francisco J. Ortiz & Co., Inc. Charlyn Industrial Pk., Road 190 KM1.9 - Lot #8, Carolina, Puerto Rico 00983 787 769-0085 [email protected] Mid-America Marketing, Inc. 203 Industrial Drive, Birmingham, AL 35211 205 879-3469 [email protected] Mid-America Marketing, Inc. 2611 Grandview Avenue, Nashville, TN 37211 615 259-9944 [email protected] Mid-America Marketing, Inc. 5466 Old Hwy. 78, Memphis, TN 38118 901 795-0045 [email protected] Smith & Stevenson Co., Inc. 4935 Chastain Ave., Charlotte, NC 28217 704 525-3388 [email protected] Harry Warren, Inc. 1400 North Orange Blossom Trail, Orlando, FL 32804 407 841-9237 [email protected] Watts Georgia 2861-B Bankers Industrial Drive, Atlanta, GA 30360 770 209-3310 [email protected]

Dave Watson Associates 1325 West Beecher, Adrian, MI 49221 517 263-8988 [email protected] Mid-Continent Marketing Services Ltd. 1275 Lakeside Drive, Romeoville, IL 60446 630 953-1211 [email protected] Soderholm & Associates, Inc. 7150 143rd Ave. N.W., Anoka, MN 55303 763 427-9635 [email protected] Stickler & Associates 203 S. Curtis Road, Milwaukee, WI 53214 414 771-0400 [email protected]

Hugh M. Cunningham, Inc. 13755 Benchmark, Dallas, TX 75234 972 888-3808 [email protected] Sandia Group, Inc. 3167 San Mateo #308, Albuquerque, NM 87110 800 339-0191 [email protected] Mack McClain & Associates, Inc. 4407 Meramec Bottom, Suite G, St. Louis, MO 63129 314 894-8188 p045 @watts.com Mack McClain & Associates, Inc. 1450 NE 69th Place, Ste. 56 Ankeny, IA 50021 515 288-0184 [email protected] Mack McClain & Associates, Inc. 15090 West 116th St., Olathe, KS 66062 913 339-6677 [email protected] OK! Sales, Inc. 214 NE 12th. St., Ste A, Moore, OK 73160 405 794-5200 [email protected]

Delco Sales, Inc. 1930 Raymer Ave., Fullerton, CA 92833 714 888-2444 [email protected] Delco Sales, Inc. 111 Sand Island Access Rd., Unit I-4, Honolulu, HI 96819 808 842-7900 [email protected] Fanning & Associates, Inc. 6765 Franklin St., Denver, CO 80229-7111 303 289-4191 [email protected] Hollabaugh Brothers & Associates 6915 South 194th St., Kent, WA 98032 253 867-5040 [email protected] Hollabaugh Brothers & Associates 3028 S.E. 17th Ave., Portland, OR 97202 503 238-0313 [email protected] P I R Sales, Inc. 3050 North San Marcos Place, Chandler, AZ 85225 480 892-6000 [email protected] REPCOR 2455 Mercantile Drive, Ste.100, Rancho Cordova, CA 95742 916 386-2233 [email protected] R. E. Fitzpatrick Sales, Inc. 4109 West Nike Dr. (8250 South), West Jordan, UT 84088 801 282-0700 [email protected]

Watts Water Technologies (Canada) Inc. 5435 North Service Road, Burlington, Ontario L7L 5H7 905 332-4090 [email protected] Con-Cur West Marketing, Inc. 71B Clipper Street, Coquitlam, British Columbia V3K 6X2 604 540-5088 [email protected] D.C. Sales Ltd. #13-6130 4th St. S.E., Calgary, Alberta T2H 2B6 403 253-6808 [email protected] D.C. Sales Ltd. 16726 111 Ave, Edmonton, Alberta T5M 2S6 780 496-9495 [email protected] GTA Sales Team. Greater Toronto Area 888 208-8927 [email protected] Hydro-Mechanical Sales, Ltd. 3700 Joseph Howe Drive, Suite 1, Halifax, Nova Scotia B3L 4H7 902 443-2274 [email protected] Hydro-Mechanical Sales, Ltd. P.O. Box 1445 (Mailing), 297 Collishaw St., Suite 7 (shipping) Moncton, New Brunswick E1C 9R2 506 859-1107 [email protected] J.D.S. Sales Ltd. 4 Lancaster Street, St. John’s, Newfoundland A1A 5P7 709 579-5771 [email protected] Les Ent. Roland Lajoie 6221 Marivaux, St-Leonard, QC H1P 3H6 514 328-6645 [email protected] Les Ent. Roland Lajoie 23 du Buisson, Pont Rouge, QC G3H 1X9 418 873-2500 [email protected] Mar-Win Agencies, Ltd. 1333 Clifton St., Winnipeg, Manitoba R3E 2V1 204 775-8194 [email protected] Northern Mechanical Sales P.O. Box 280 (mailing) 163 Pine St. (shipping), Garson, Ontario P3L 1S6 705 693-2715 [email protected] Palser Enterprises, Ltd. P.O. Box 28136 (mailing), 1885 Blue Heron Dr., #4, London, Ontario N6H 5L9 519 471-9382 [email protected] RAM Mechanical Marketing Inc. 905 Winnipeg Street, Regina, Saskatchewan S4R 1J1 306 525-1986 [email protected] RAM Mechanical Marketing Inc. 510 Ave M South, Saskatoon, Saskatchewan S7M 2K9 306 244-6622 [email protected] Walmar Mechanical Sales 24 Gurdwara Rd., Nepean, Ontario K2E 8B5 613 225-9774 [email protected]

EXPORTHdqtrs.: Watts Regulator Co. 815 Chestnut St., North Andover, MA 01845-6098 U.S.A. 978 688-1811 [email protected]

E-mailTelephone

For Technical Assistance Call Your Authorized Watts Representative.C

anad

aS

out

h C

entr

al

1116

No

rth

Eas

tM

id

Atl

anti

cS

out

h E

ast

No

rth

Cen

tral

Wes

tern

F-ProdSelectionGuide 1038 © 2011 Watts

USA: No. Andover, MA • Tel. (978) 688-1811 • Fax: (978) 794-1848 • www.watts.comCanada: Burlington, ON • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

A Watts Water Technologies Company