Coanda Power Systems - Elgin Equipment Group
-
Upload
cooklegacytraining -
Category
Business
-
view
357 -
download
5
Transcript of Coanda Power Systems - Elgin Equipment Group
EEG Water
Coanda Power Systems
The World Needs Power
Coanda Power Systems are a tool to help reach this need
To pump water
To run small industry
To charge my phone
To watch my team
To connect to the world
Power needs to be clean
Power needs to be cost effective
Power needs to simply work
Small Hydro Made Simple
Aggregate Mean Cost of Micro, Mini & Small Hydro for Low Head & High Head Sites
$1-$4 MM/Installed MW*
Lower construction cost through innovative equipment tuned to segment & region.
*Estimate from US Energy Association & European Small Hydro Association
Equipment & Other
Construction & Civil
Elgin Gear Reduces Civil
Cost
Diversion & ScreeningDesander
Turbine
Plant Controls
Switchgear
Monitoring & Controls
Regulation Chamber
Penstock
Intake Structure
Generator
Tailrace
Transmission & Distribution
Power House
Power Distribution Equipment
Small Hydro
Made Simple
head
𝑃 = 𝑄𝐻𝐾𝐺Where:Q=flowH=headK=efficiencyG=gravity
Diversion & ScreeningDesander
Turbine
Plant Controls
Switchgear
Regulation Chamber
Penstock
Intake Structure
Generator
Tailrace
Transmission & Distribution
Power House
Power Distribution Equipment
Small Hydro
Made Simple
head
Simplify the intake with Coanda Intake design
Simplify the intake with Innovative Turbines
Simplify the intake with unitized or modular construction
Micro & Mini (<1MW) Small (1-10 or 25 MW)
Low
Hea
dH
igh
Hea
d
Correct turbine and supporting gear optimized for the low head space.
Contract manufacturing for small hydro turbines
Modular equipment to simplify installation & commissioning
Innovative equipment to lower civil capex
Small Hydro
Coanda Power Systems
• Simple to Permit
• Simple to Design
• Simple to Install
• Simple to Operate
Coanda Power Systems make small hydro development SIMPLE…
Coanda Power Proposition
Simplify the intake with Coanda Intake design
Simplify the intake with Innovative Turbines
Simplify the intake with unitized or modular construction
Cost Item Typical Savings
Desilting structure Cap-Ex 10%
Desilting structure excess flow 5%
Coanda operating cost 5%
Lower civil work 5-15%
Lower mitigation cost 10%
Lower maintenance Varies
Lower civil work for site preparation
10%
Lower field labor time 10%
Simplified installation 5%
Hydro Intake Structures
Coanda Screens• Inclined screens that use overflowing water to stay clean• Dramatically simplify the development of small hydro plants
Gates• Water control devices• Part of almost every intake system• Developing design for manufacture at Tabor
Modular Intakes• Coanda Screens• Collection Chamber• Transition Box• Controls• Bypass Gates
Hydro Powerhouse Equipment
CPS Micro turbines• Coanda Power Systems use small micro-turbine
generators. • Turbine, generator, valves, and controls are
provided in a shipping container.
Contract Manufacturing & Partnership for Small Hydro Turbines.
Hydro Switchgear Equipment
Switchgear Components• Each hydroelectric project requires a switchyard.• For micro & mini hydro projects, this is small power factor correction, relaying, and protection.• For large projects (>25 MW), a mod-power substation is ideal.
Turnkey Small Hydro
• An estimated 1,443 GW of hydro capacity will be added globally in the coming decade. The goal of Coanda Power Systems is to simplify the development of these sites.
• Simple to Permit — Coanda Power Systems allow clean water to fall through while fish and debris pass over. Thus, a properly designed system can easily create power without harming the environment.
• Our world class experience in the design of intake structures, controls, and switchgear allows us to provide the major equipment for a small hydro plant as an engineered product.