Transcript of Coal Testing and Analysis Methods
Methods
of
Coal Testing and Analysis
( Series-1)
Wide Publishing ( A Division of Wide Educational Products and Services)
7/1/1,Samar Sarani
( At Radio Galley,on DumDum Road ,Near Dumdum Chiria More )
Kolkata-700002.INDIA
Phone: +913325468733, Fax: +913325468733
Mobile No:+91 9339682179/ +91 9007744212
website:http://www.widepublishing.com
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Combustion Quality of Coal and Lignite
Determination of Hard Groove
Index of Coal• Procedure:
• Take coal sample and pass it through 4.75 mm mesh
• Air dry it for 24 to 48 hours in well ventilated place
• After drying grind & Sieve it in 1.18 mm (ASTM16) and 6000micron (ASTM30 ) sieves
• At least 50% of the original sample should pass through 1.18mm sieve
• Take 50+ 0.1 grams of the sample of -1.183mm + 600micron size (passed through 1.18mm sieve and retained on 600micron sieve) in HGI instruments sample bowl
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Guidance for Solving Environmental Challenges of Mining, Construction,
Processing and Oil and Gas Fields Projects.
Determination of Hard Groove
Index of Coal
• Keep the 8 ball rollers of 25.400+0.003 mm dia on the sample and fix the sample bowl to the instrument
• Switch on the instrument
• The instrument will be stopped after 60+ 1 revolutions (in 3 Minutes)
• Remove the bowl from the instrument and sieve the sample through the 75 micron (IS 8) sieve
• Keep it in desiccators for 15 minutes
• Weigh the sample and its weight in M
• HGI is calculated by the formulae HGI = 13 + 6.93 × M
Land Acquisition and Strategic Corporate Social Responsibility
Management - Manual For Resource Intensive Core Industries
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Where ‘M’ is the mass of the sample passed through 75 microns sieve after grinding and measuring in
balance ( fig)
PROJECT ENVIRONMENTAL CLEARANCE ENGINEERING AND
MANAGEMENT ASPECTS For Fuel & Non – Fuel Minerals Producing
And User Industries
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
To determine the GROSS CALORIFIC VALUE OF coal samples using Auto
Coal Analyser
• To assess the heating value of Coal in terms of GCV to know the worth use of coal
• Procedure:
• Start the instrument and bring it to analyze mode
• Open the oxygen gas cylinder and see that the outward pressure should be 450 psi
• Calibrate the instrument with Benzoic acid pellet
• Accurately weighs 1 gram of Coal sample into crucible
• Prepare the combustion vessel as explained in the calibration procedure
• Draw 2 ltrs. Water in to the pipette from the pipette tank
• Release the water in to the bucket from the pipette by turning the stopper
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Regulatory and Community Requirements of Industrial Project Clearance
Mining, Oil & Gas, Steel, Aluminum, Cement Industries and Other Core
Sectors
• Transfer the bucket into the bucket well ,
place the prepared combustion vessel in
the
• bucket and connect the fuse leads to the
combustion vessel
• Enter the sample weight and id code and
press start button
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Rehabilitation and Resettlement Issues of People Affected in Project Land
Acquisition- Administrative, Social and Regulatory Mechanisms-
• Pre fire of 3 minutes and post fire 5 minutes time takes place automatically and GCV value will be displayed on the screen after 8 minutes
• Remove the combustion vessel from the bucket and expel the gases in it
• Clean and keep ready for next analysis
• Take out the bucket and transfer water back to reservoir
• Allow the analyzer to equilibrate
• Press menu and press (2) and select results
• Press menu and press (8) to enter the corrections of fuse wire, Moisture %, Ash %, nitrogen and sulphur values
• After entering the values for all the samples press menu and press (6) to get the print out of GCV values of all the samples
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
STRATEGIC MANAGEMENT OF ALLIANCE,MERGER AND
ACQUISITIONS
Precautions to be taken
• Fasten the wire tightly under the sleeves
• Adjust the pressure of the oxygen cylinder to fill the bomb vessel slowly
• Care should be taken while the crucible with sample to avoid spillage of the sample
• Expel the gas slowly while diffusing the bomb vessel after analysis
• Repeat the analysis if any un burnt sample is found in the crucible after analysis
• Maintain correct water level in the pipette tank
• Calibration of the instrument should be done regularly to avoid errors
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Trade and Market for Minerals, Metals, Oil and Gas - Dynamics and
Determinants
Calibration procedure of GCV analyzer
• Weigh accurately one benzoic acid pellet in a crucible
• Place the crucible with in sample holder of combustion vessel and fix both ends of 10cms fuse wire in the both sleeves and arrange the wire in such a way that it is just above the sample
• Place the sample holder in the combustion vessel and close the lid tightly
• Fill the bomb with oxygen to a pressure of 450 psi (Automatically cut off)
• Fill the pipette of 2 liters capacity attached to the instrument with water from the tank
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Combustion Quality of Coal and Lignite
• Draw water from pipette in to the bucket
• Transfer bucket in to the well and place prepared combustion vessel in the bucket and connect the fuse leads enter the sample weigh and id-code and press start button
• Pre fire and post fire takes place and GCV value will be displayed at the end of 8min
• Remove the combustion vessel from the bucket and expel the gases , clean and keep ready for the sample analysis
• Press menu and press (3) to select the current GCV value of the benzoic acid
• Press menu and press (4) to calculate calibration enter the standard GCV value 6318 and press yes
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Guidance for Solving Environmental Challenges of Mining, Construction,
Processing and Oil and Gas Fields Projects.
An Auto Coal Analyzer
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
Land Acquisition and Strategic Corporate Social Responsibility
Management - Manual For Resource Intensive Core Industries
Thank You
Wide Educational Products and Services. 7/1/1, Samar Sarani (At Radio Galley on Dumdum Road, Near Dumdum Chiriamore) Kolkata – 700002,
West Bengal, India. Phone : (033)25468733 / Fax : (033) 25468733 Mobile : 09339682179 / 09007744212. Email : [email protected].
PROJECT ENVIRONMENTAL CLEARANCE ENGINEERING AND
MANAGEMENT ASPECTS For Fuel & Non – Fuel Minerals Producing
And User Industries