www.scfingenieria.com
COAL COMBUSTION BASELINE
TESTING
www.scfingenieria.com
www.scfingenieria.com
MEASURING PRIMARY AIR FLOW 1
EQUIPMENT
We use state of the art Dirty Air Pitot with a hand held recorder that averages readings providing very accurate measurement.
PROCEDURE
If the ports are not installed, we provide the installation using 1½”, full port valves. These ports can be used for air flow as well as Coal flow measurements.
Balancing air flows to all burners in a Coal Fired Boiler is the best way to improve combustion with minimum investment.
www.scfingenieria.com
MEASURING COAL FLOW 2
Is the Manufacturer of the PFS-A-SL AUTOMATIC PULVERIZED FUEL SAMPLER. This PLC controlled testing assures isokinetic flow testing with in-site weighing and automatic coal flow calculation .
A two man team is used to obtain the coal samples. One supervises the probe, while the other enters data on the PLC and runs the test.
M&W ASKETEKNIK
With a multiple nozzle sampler and a computer controlled electric actuator we provide testing according to ISO-9931.
www.scfingenieria.com
VERIFYING SECONDARY AIR FLOWS 3
PROCEDURE
This highly accurate anemometer provides velocity readings with an accuracy of ± 3 % which allows for very clear determination of flow variations around the burner secondary air register. By graphing the velocities at 24 points it becomes clear where disturbances are present.
EXPERIENCE
We have provided burner secondary air flow measurements, finding flow distortions caused by uneven air distribution within the air box.
EQUIPMENT
TYPICAL COAL BURNER
Secondary Air
VELOCITY PROFILE
Anemometer
www.scfingenieria.com
GATHERING EMISSIONS 4
We design manufacture and install the necessary test ports to get a complete traverse grid across the duct. This multiple point sampling allows for a very precise measurement of the emissions generated by each burner.
RESULTS
The graph to the left represents the variations of NOx across a duct with a nine point sampling grid. It is very evident that one point sampling would NOT have being representative of the NOx levels present in most of the duct.
EQUIPMENT
We use the Testo 350-S which allows simultaneous in-site monitory of NOx, CO, O2 and CO2 .
NOx [PPM] - 100% LOAD
622
759755
698
760
801
716
751
758
600
620
640
660
680
700
720
740
760
780
800
820
1 2 3
NO
x [
PP
M]
Sampling points
LEVEL A
LEVEL B
LEVEL C
www.scfingenieria.com
CONTACTS USA Miguel Gonzalez, (312) - 965 63 14
Email: [email protected] Jaime Gonzalez, (305) - 359 59 63
Email: [email protected]
CONTACTS COLOMBIA Jaime Gonzalez (+57) 310 688 41 36
OUR MISION
To provide efficiency improvement solutions to Coal Fired Power Plants in Central and South America, incorporating well proven
Sate of the Art technologies.
PRODUCTS
Coal burner upgrades to reduce NOx. Classifier upgrades to improve fineness. Venturi flowmeter to measure primary air. New classifiers with state of the art technology. Emissions monitoring equipment. Continue furnace video monitoring. Infrared FEGT monitoring.
SERVICES
Combustion baseline testing. Primary air flow measurement for CFD Modeling of Burners and OFA. Coal pipes flow measurement for classifier upgrades and wind box flow balancing. Sampling gas emissions in coal fire power plants. Seminars in Spanish, on all the products and services offered by SCF.
5