CM Booster Self-Priming - Kingspan | AustraliaFeatures Self-priming With a suction lift of up to 8...

2
Features Self-priming With a suction lift of up to 8 metres (self-priming up to 4 metres), the CM Booster Self-Priming is ideal for pressurising water from above or below ground water sources. Robust design All wetted parts are made from high quality, corrosion resistant stainless steel to ensure the longest life possible. User-friendly interface The pump features a user-friendly interface with LED indicators displaying power status, pump running, alarm indication and pressure indication (excluding CMB-SP 1-36). Protective features The pump incorporates a range of protective features such as; dry run protection, thermal overload protection, cycling alarm and maximum continuous operation time - 30 mins (excluding CMB-SP 1-36) to protect the pump and ensure a long life. Easy installation The booster unit is a compact and adaptable solution, which makes it suitable for most installations. Simply connect the inlet and outlet and adjust the start pressure to suit individual requirements and you have a fully operational booster unit. Integrated non-return valve Non-return valve for backflow prevention. The Grundfos CM Booster Self-Priming is a compact booster pump designed for domestic and light industrial use. The booster unit consists of a robust multistage centrifugal pump and a generator friendly PM1 or PM2 Pressure Manager. The Pressure Manager allows the pump to start and stop automatically according to demand and protects the pump from dry running. The CM Booster Self-Priming is the perfect solution if you are struggling with insufficient mains pressure, and can also be used with above or below ground water sources. CM Booster Self-Priming Applications - Mains boosting - Household water supply - Boosting from above ground water tanks - Boosting from below ground water sources e.g. below ground tank/dam - Light industrial use

Transcript of CM Booster Self-Priming - Kingspan | AustraliaFeatures Self-priming With a suction lift of up to 8...

Page 1: CM Booster Self-Priming - Kingspan | AustraliaFeatures Self-priming With a suction lift of up to 8 metres (self-priming up to 4 metres), the CM Booster Self-Priming is ideal for pressurising

FeaturesSelf-primingWith a suction lift of up to 8 metres (self-priming up to

4 metres), the CM Booster Self-Priming is ideal for pressurising

water from above or below ground water sources.

Robust designAll wetted parts are made from high quality, corrosion

resistant stainless steel to ensure the longest life possible.

User-friendly interfaceThe pump features a user-friendly interface with LED

indicators displaying power status, pump running, alarm

indication and pressure indication (excluding CMB-SP 1-36).

Protective featuresThe pump incorporates a range of protective features such as;

dry run protection, thermal overload protection, cycling alarm

and maximum continuous operation time - 30 mins (excluding

CMB-SP 1-36) to protect the pump and ensure a long life.

Easy installationThe booster unit is a compact and adaptable solution, which

makes it suitable for most installations. Simply connect the

inlet and outlet and adjust the start pressure to suit individual

requirements and you have a fully operational booster unit.

Integrated non-return valveNon-return valve for backflow prevention.

The Grundfos CM Booster Self-Priming is a compact booster pump designed for domestic and light industrial use. The booster unit consists of a robust multistage centrifugal pump and a generator friendly PM1 or PM2 Pressure Manager. The Pressure Manager allows the pump to start and stop automatically according to demand and protects the pump from dry running. The CM Booster Self-Priming is the perfect solution if you are struggling with insufficient mains pressure, and can also be used with above or below ground water sources.

CM Booster Self-Priming

Applications - Mains boosting- Household water supply- Boosting from above ground water tanks- Boosting from below ground water sources e.g. below ground tank/dam- Light industrial use

Page 2: CM Booster Self-Priming - Kingspan | AustraliaFeatures Self-priming With a suction lift of up to 8 metres (self-priming up to 4 metres), the CM Booster Self-Priming is ideal for pressurising

The

nam

e G

rund

fos,

the

Gru

ndfo

s log

o, a

nd b

e th

ink

inno

vate

are

regi

ster

ed tr

adem

arks

ow

ned

by G

rund

fos H

oldi

ng A

/S o

r Gru

ndfo

s A/S

, Den

mar

k. A

ll rig

hts r

eser

ved

wor

ldw

ide.

How tHe SQ(e) protectS and reduceS wear

VolTAGE hAndlInG

Increased winding temperature caused by under voltage often reduces the lifespan of the pump. The SQ(E) motor is protected against voltage fluctuations including over and under voltage.

dry runnInG ProTEcTIon

The SQ(E) pump is factory pre-set based on minimum power consumption. Dry-running protection is activated 40 seconds after power is connected to allow priming of the pump. When there is no water in the hydraulics, power consumption is reduced. The SQ(E) stops automatically when below the dry run power limit and restarts automatically within 5 minutes after cut-out.

SQe and cu301conSTAnT PrESSurE oPErATIon

When using a CU301 controller with the SQE pump, water pressure will always remain constant regardless of how much water is being consumed. As more taps are opened, the pump automatically increases its speed, maintaining the chosen pressure at any flow rate.

PowEr lInE communIcATIon

The SQE communicates with the CU301 without the need for additional cables. If there is a failure at the pump, via the power cable, simple diagnostics can take place.

SImPlE ProGrAmmInG

The CU301 has a simple interface with up/down buttons to control the pressure of the pump. Hold both the up and down buttons for 5 seconds and the unit is locked - easy.

SofT STArT

Soft start ensures a low starting current with a smooth and steady acceleration. This offers excellent starting reliability at low voltage, prevents overload of the mains power, reduces water hammer in the pipe and reduces pump wear.

for morE InformATIon conTAcT:

PowEr SuPPly

Low ampere usage makes it possible to connect more appliances to the same fuse group or reduce the size of the power line. Small generators can be used with SQ(E).

Grundfos recommends to use a generator with a capacity 50% higher than rated pump power consumption.

The SQ(E) pump provides several features that simplify your installation and add reliability to the system.

150 180 200

207 V 244 V

Conventional AC Motor

SQ SQ

220 240 260 280 315

Supply voltage [V]

Current

Time

Soft start

Direct online (DOL)

2 sec.protective Feature SQ(e) conventional

ac motor SQe + cu301

Over voltage / under voltage protection ✔ ✖ ✔

Integrated dry running protection ✔ ✖ ✔

Over temperature protection ✔ ✖ ✔

Overload protection ✔ ✖ ✔

Start function with high torque and without starter box ✔ ✖ ✔

Visual fault indication alarm ✖ ✖ ✔

Variable speed control ✖ ✖ ✔

H

Q

Q

PP1P cut-out

H

Q

Q

PP1P cut-out

pertH 63 McDonald Crescent Bassendean, WA, 6054 F: 08 9279 7005

MeLBourne 24 Healey Road Dandenong South, VIC, 3175 F: 03 9706 9533

CLAYTON ENGINEERING P: 1300 798 022 E: [email protected]

BrISBane 26 French Ave Brendale, QLD, 4500 F: 07 3881 2780

The

nam

e G

rund

fos,

the

Gru

ndfo

s log

o, a

nd b

e th

ink

inno

vate

are

regi

ster

ed tr

adem

arks

ow

ned

by G

rund

fos H

oldi

ng A

/S o

r Gru

ndfo

s A/S

, Den

mar

k. A

ll rig

hts r

eser

ved

wor

ldw

ide.

How tHe SQ(e) protectS and reduceS wear

VolTAGE hAndlInG

Increased winding temperature caused by under voltage often reduces the lifespan of the pump. The SQ(E) motor is protected against voltage fluctuations including over and under voltage.

dry runnInG ProTEcTIon

The SQ(E) pump is factory pre-set based on minimum power consumption. Dry-running protection is activated 40 seconds after power is connected to allow priming of the pump. When there is no water in the hydraulics, power consumption is reduced. The SQ(E) stops automatically when below the dry run power limit and restarts automatically within 5 minutes after cut-out.

SQe and cu301conSTAnT PrESSurE oPErATIon

When using a CU301 controller with the SQE pump, water pressure will always remain constant regardless of how much water is being consumed. As more taps are opened, the pump automatically increases its speed, maintaining the chosen pressure at any flow rate.

PowEr lInE communIcATIon

The SQE communicates with the CU301 without the need for additional cables. If there is a failure at the pump, via the power cable, simple diagnostics can take place.

SImPlE ProGrAmmInG

The CU301 has a simple interface with up/down buttons to control the pressure of the pump. Hold both the up and down buttons for 5 seconds and the unit is locked - easy.

SofT STArT

Soft start ensures a low starting current with a smooth and steady acceleration. This offers excellent starting reliability at low voltage, prevents overload of the mains power, reduces water hammer in the pipe and reduces pump wear.

for morE InformATIon conTAcT:

PowEr SuPPly

Low ampere usage makes it possible to connect more appliances to the same fuse group or reduce the size of the power line. Small generators can be used with SQ(E).

Grundfos recommends to use a generator with a capacity 50% higher than rated pump power consumption.

The SQ(E) pump provides several features that simplify your installation and add reliability to the system.

150 180 200

207 V 244 V

Conventional AC Motor

SQ SQ

220 240 260 280 315

Supply voltage [V]

Current

Time

Soft start

Direct online (DOL)

2 sec.protective Feature SQ(e) conventional

ac motor SQe + cu301

Over voltage / under voltage protection ✔ ✖ ✔

Integrated dry running protection ✔ ✖ ✔

Over temperature protection ✔ ✖ ✔

Overload protection ✔ ✖ ✔

Start function with high torque and without starter box ✔ ✖ ✔

Visual fault indication alarm ✖ ✖ ✔

Variable speed control ✖ ✖ ✔

H

Q

Q

PP1P cut-out

H

Q

Q

PP1P cut-out

pertH 63 McDonald Crescent Bassendean, WA, 6054 F: 08 9279 7005

MeLBourne 24 Healey Road Dandenong South, VIC, 3175 F: 03 9706 9533

CLAYTON ENGINEERING P: 1300 798 022 E: [email protected]

BrISBane 26 French Ave Brendale, QLD, 4500 F: 07 3881 2780

DimensionsPerformance

CM Booster Self-Priming

Operating ConditionsSystem pressureMax. 10 bar

Liquid temperature0 °C to 60 °C

Ambient temperatureMax. 55 °C

Relative air humidityMax. 95 %

Technical DataMains voltage1 x 240 V, 50 Hz

Enclosure classIP55

Insulation classF

Sound pressure level55 dB

Start/stop frequencyMax. 100 per hour

Approvals and markingsASNZ4020, CE

ModelPower (kW)

Connections Dimensions (mm) Weight (kg)Outlet Inlet A B C

CMB-SP 3-37 0.5 1” M 1” F 377 317 75 14.1

CMB-SP 3-47 0.5 1” M 1” F 413 317 75 14.4

CMB-SP 5-47 0.9 1” M 1” F 453 317 75 16.9

A

B

C

Old models Suitable replacement models

CH-PC CM Booster CM Booster Self-Priming

CH2-50 PC CMB 3-4 CMB-SP 3-37

CH2-60 PC CMB 3-5 CMB-SP 3-47

CH4-50 PC CMB 5-5 CMB-SP 5-47

Please Note: Conversion at 250 kPa

0.0 0.4 0.8 1.2 1.6 Q [l/s]

0.0 20 40 60 80 100 Q [l/min]

0.0 1 2 3 4 5 6 Q [m3/h]

0

10

20

30

40

50

H [m]

7

CMB-SP 5-47

CMB-SP 3-37

CMB-SP 3-47

Fonts Converted to Outlines

Kingspan Environmental Pty LtdHEAD OFFICE8 Bessemer Street, Blacktown NSW 2148P: 1300 736 562 • F: 1300 736 582E: [email protected] 62 108 491 881

NEW SOUTH WALESVICTORIAQUEENSLAND