Cloud Object Storage | Store & Retrieve Data …CHS-85 19 3/4 14 1/2 33 3/8 16 7/8 3 5/8 CHS-110...
Transcript of Cloud Object Storage | Store & Retrieve Data …CHS-85 19 3/4 14 1/2 33 3/8 16 7/8 3 5/8 CHS-110...
• Cascading up to 8 units• Stainless steel down-fired fire tube design• Eight models from 85,000 to 399,000 BTU/Hr• Full modulation up to 10:1 turndown• Advanced Honeywell Sola Boiler
Controller with backlit screen display• Low NOx operation• Venting to 150'• 2" venting option on two models• PVC, CPVC, Polypropylene or Stainless
Steel venting
Condensing High Efficiency Stainless SteelSeries Gas Boiler
Make the right move.When it comes to heating your home, it’s important to choose a de-pendable boiler that will give you optimum fuel savings. The CHSboiler offers eight different sized models to match the heating require-ments of the home. These boilers are modulating, condensing, stain-less steel, wall mount boilers. With sizes ranging from85,000-399,000 Btu/hr inputs and modulation up to 10:1 turndownmaximizes your fuel savings. They offer installation flexibility with op-tions such as topor bottom supplyand return con-nections, top orbottom gas con-nections, ventruns of up to 150ftand five vent ter-mination options.
EfficiencyEngineered to thehighest of standards, the CHS Stainless Steel Fire Tube design HeatExchanger can deliver up to 99% Thermal Efficiency, low-nox emis-sions and a fully modulating burner. It is the clear choice whenchoosing a boiler in today’s “Go Green” focused market.
DependableThe new CHS Boiler is yet another example of Slant/Fin’s goal ofproviding the very best heat exchanger designs and CondensingHigh Efficiency Boiler options to the industry. The CHS series boileris manufactured to the highest industry standards. The ASME certi-fied fire-tube exchanger is constructed of stainless steel for bettercorrosion resistance. Each boiler is factory tested three ways to besure of top performance. The CHS Boiler, combined with Slant/Fin’sindustry leading Customer/ Technical Service departments, resultsin a sure fire winning choice.
*
* 5 year parts and laborwarranty excludes- 300-399 models
Look for ourHydronic Explorer appon iTunes, Google Play and atwww.hydronicexplorer.com
(Works on iPad, iPhone & Android devices)
www.slantfin.com
Cascades up to 8 units
®
BOILERS & BASEBOARD
We Build Trust and Comfort
Since 1949
The ControlThe Slant/Fin CHSboiler has an advancedHoneywell control thatprovides easy navigationand offers completeauto-diagnostics. All theinformation needed toset up, monitor boilerfunctions and service iseasy to access. Theeasy to use control al-lows for multiple circula-tors and temperaturezones and has an inte-grated cascade featureto join multiple boilers.
Boiler Features• Easy to install and maintain• Down-fired, Fire Tube stainless steel boiler• Stainless steel internal water connections• Certified internal low water cutoff with test button• Fully-modulating combustion system• Condensate pump electrical receptacle• Built-in gas drip leg• Wall-mount configuration with optional floor stand• Improved venting orientation with flue test port• On/off power service switch, built in• High-quality metallic clear coat finish• High-energy external spark generator for
reliable ignition• ASME certified boiler• Certified ANSI Z21.13• 15-year limited warranty
Control Features• Accurate control with Honeywell Sola Boiler
Control with backlit screen displaying system info with easy step by step programming
• Outdoor reset system water temperatureimproves efficiency and heating comfort
• Built in lead lag multiple boiler cascade control handles up to 8 CHS boilers. 4.2 – 10 mA boiler external boiler management input
• Can control three separate temperature setpoints• Controls up to three circulators
a. DHW Circulatorb. Boiler Circulatorc. System Circulator
• Modbus capability is built in• Built in boiler diagnostics• Built in DHW and space heating control• Shut down based on outdoor temperature• Alarm contacts• Freeze protection
Down-fired Fire TubeThe CHS heat exchangeris ASME certified, burneris down-fired. The tubeshave a dimpled design tooptimize heat transfer,which increases energy ef-ficiency. The Fire Tubesprovide generous spacefor flue gas to pass, andsignificantly reduce theneed for cleaning due tothe vertical configurationand self-cleaning operationwhen in condensing mode.
FlexibilityThe design of the CHSoffers more flexibility thanany other boiler on themarket, with vent runs upto 150', five vent termina-tion options, 2" optionalventing on some modelsand plumbing and gasconnections at either topor bottom.
User InterfaceProvides easy naviga-tion to all of the con-troller’s parameters andsetpoints. The backlitscreen continuously dis-plays system informa-tion to ensure safe andefficient operation.
®
C US
©Slant/Fin Corp. 2016 • Printed in the U.S.A. 816 • Publication No. CHS-10
SLANT/FIN CORPORATION, Greenvale, N.Y. 11548Phone: (516) 484-2600 • FAX: (516) 484-0933www.slantfin.com
**Max length of 150' for 3" venting only, 100' for 2" vent † Gross output * CHS399 & CHS340 efficiency is Thermal Efficiency • Reducer required
"D""E"
"C"
FRONT
"A"
"B"
TOP
MODEL “A” “B” “C” “D” “E”CHS-85
19 3/4 14 1/2 33 3/8 16 7/8 3 5/8CHS-110CHS-154
19 3/4 18 1/2 33 3/8 16 3/4 3CHS-175CHS-200CHS-250CHS-340
25 20 36 3/8 22 1/2 3 7/8CHS-399
SeriesBoiler
Boiler Dimensions
Boiler Ratings
Model
C.S.A.Max Input
NG/LP(MBH)
C.S.A.Min Input
NG/LP(MBH)
D.O.E.Capacity
(MBH)
NetAHRI(MBH)
A.F.U.E.%
VentDiameter(Inches)
MaxVent
LengthNG/LP (Ft)
Approx.Water
Content(Gal.)
Supply &Return
Piping MaleNPT (Inches)
GasConnectionMale NPT(Inches)
CHS-85CHS-110CHS-154CHS-175CHS-200CHS-250CHS-340CHS-399
85/88108/113
154175200250340399
17/17.621.6/22.6
15.4313131
39.939.9
7899141163185230324380†
6886122141160199282330
95.095.095.095.095.095.095.4*95.4*
2• or 32• or 3
333344
150**150**100100100100100100
3.23.24.94.94.94.96.46.4
11
1 1/41 1/41 1/41 1/41 1/21 1/2
1/21/21/21/21/21/23/43/4