Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance...
Transcript of Closed Circuit Fluid Cooler - HTS · Induced draft counterflow design. CTI certified in accordance...
THERMAL PERFORMANCE CERTIFIED BY THE COOLING TECHNOLOGY INSTITUTE
REYMSA´s complete line of Closed Circuit Fluid Coolers are certified by the CTI in accordance with Standard STD-201.
Self contained heat transfer equipment.
Induced draft counterflow design.
CTI certified in accordance with standard STD-201.
Long life construction.
36 different models.
Nominal Capacity: from 80 to 1,035 GPM @ Standard conditions: 95ºF / 85ºF / 78ºF.
Easy access for maintenance.
Easy and economical assembly and installation.
All Non-Corrosive construction materials.
FEATURES:
Leader in “ All-Fiberglass ” Cooling Towers
REYMSA´s success is the result of 35 years of experience in Cooling Towers. We have been putting ideas into action by researching and developing the latest technologies; therefore, we are proud to offer our Closed Circuit Fluid Coolers.
Sound Deflectors.
Access Ladders.
Handrails (Stainless or Galvanized steel).
Vibration Cut off Switches.
Basin Heaters.
Electric Water Level Control.
Non-Skid Catwalk (Stainless or Galvanized steel).
Equalizer Connection for Multiple Tower Installations.
Filtration System: RFS SERIES.
Tower casing construction with flame retardant resin according to the ASTM-E84 Standard.
OPTIONAL EQUIPMENT
Basin Heater SystemElectric Water Level Control
Durable and heavy duty construction.
Gel-coat with UV inhibitors provides superior protection from harsh environments, weather, and aggressive chemical treatment.
Light weight.
Thermally stable composition.
Corrosion resistant.
Minimal maintenance.
BENEFITS
FRP (FIBERGLASS REINFORCED POLYESTER)CASING AND STRUCTURE
REYMSA uses the best fan on the market, using cast
aluminum hubs and adjustable pitch air foil blades
made with glass reinforced polyamide.
Blades material is able to resist high vibration levels.
Ambient operating air temperatures may fluctuate
from - 50ºF to 250ºF.
PAG (GLASS REINFORCED POLYAMIDE)AXIAL FANS
With a superior motor provides the lowest possible
maintenance cost and the most reliable equipment.
Virtually maintenance free: NO belts to adjust and NO
gear boxes to lubricate.
Low speed, NEMA frame, TEFC, Premium Efficiency,
Severe duty, Marine duty, Inverted duty rated fan motors.
All our tower models feature motors that exceed the
Cooling Tower duty motor characteristics.
DIRECT DRIVE SYSTEM
Corrosion resistant Glass ReinforcedPolyamide fan blades
Direct Drive System
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
THERMAL PERFORMANCE CERTIFIED BY THE COOLING TECHNOLOGY INSTITUTE
REYMSA´s complete line of Closed Circuit Fluid Coolers are certified by the CTI in accordance with Standard STD-201.
Self contained heat transfer equipment.
Induced draft counterflow design.
CTI certified in accordance with standard STD-201.
Long life construction.
36 different models.
Nominal Capacity: from 80 to 1,035 GPM @ Standard conditions: 95ºF / 85ºF / 78ºF.
Easy access for maintenance.
Easy and economical assembly and installation.
All Non-Corrosive construction materials.
FEATURES:
Leader in “ All-Fiberglass ” Cooling Towers
REYMSA´s success is the result of 35 years of experience in Cooling Towers. We have been putting ideas into action by researching and developing the latest technologies; therefore, we are proud to offer our Closed Circuit Fluid Coolers.
Sound Deflectors.
Access Ladders.
Handrails (Stainless or Galvanized steel).
Vibration Cut off Switches.
Basin Heaters.
Electric Water Level Control.
Non-Skid Catwalk (Stainless or Galvanized steel).
Equalizer Connection for Multiple Tower Installations.
Filtration System: RFS SERIES.
Tower casing construction with flame retardant resin according to the ASTM-E84 Standard.
OPTIONAL EQUIPMENT
Basin Heater SystemElectric Water Level Control
Durable and heavy duty construction.
Gel-coat with UV inhibitors provides superior protection from harsh environments, weather, and aggressive chemical treatment.
Light weight.
Thermally stable composition.
Corrosion resistant.
Minimal maintenance.
BENEFITS
FRP (FIBERGLASS REINFORCED POLYESTER)CASING AND STRUCTURE
REYMSA uses the best fan on the market, using cast
aluminum hubs and adjustable pitch air foil blades
made with glass reinforced polyamide.
Blades material is able to resist high vibration levels.
Ambient operating air temperatures may fluctuate
from - 50ºF to 250ºF.
PAG (GLASS REINFORCED POLYAMIDE)AXIAL FANS
With a superior motor provides the lowest possible
maintenance cost and the most reliable equipment.
Virtually maintenance free: NO belts to adjust and NO
gear boxes to lubricate.
Low speed, NEMA frame, TEFC, Premium Efficiency,
Severe duty, Marine duty, Inverted duty rated fan motors.
All our tower models feature motors that exceed the
Cooling Tower duty motor characteristics.
DIRECT DRIVE SYSTEM
Corrosion resistant Glass ReinforcedPolyamide fan blades
Direct Drive System
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
BENEFITS
Direct-drive, with axial, sickle shaped type, adjustable-pitch fan blades.
Fabricated of corrosion resistant glass reinforced polyamide.
Operation temperature range : -50°F to 250°F.
Low noise emission.
High performance at lower speeds.
High strength due to its large cord.
The vertical inline recirculating pump is designed for optimum performance, easy installation and simplified maintenance.
The close-coupled design results in improved alignment and increased seal life. No isolation pads required.
OPTIONAL LOW NOISE FAN
RECIRCULATING PUMP
Recirculating Pump
Low Noise Fan
Copper is easy to work with, and has excellent thermal conductivity, corrosion resistance and durability.
Stainless steel casing.
Wide diagonal spacing for easy cleaning.
Type L copper.
Designed to block direct sunlight to the water, to minimize algae growth, reduce splash out and noise.
Fabricated from rigid, corrugated UV protected Polyvinyl Chloride (PVC); is easy removable to provide access for cleaning. Resistant to rot, fungi, bacteria and organic/inorganic acids and alkalis.
Meets CTI STD-136.
Flame spread rating is less than 20 according to ASTM E84, and self-extinguishing in less than 5 seconds according to ASTM D635.
COPPER COILS
AIR INLET LOUVERS
Durable, corrosion resistant copper coils.
Air Inlet Louvers
Manufactured of Polyvinyl Chloride (PVC); resistant to rot,
fungi, bacteria and organic/inorganic acids and alkalis
commonly found in cooling towers.
Meets CTI STD-136.
Fill media modules flame spread rating is less than 20
conforming to ASTM E84, and self-extinguishing in less
than 5 seconds conforming to ASTM D635.
Every tower is assembled and tested at the factory prior to shipment.
REYMSA has a deep commitment with customer satisfaction to build long term relationships.
FILM FILL MEDIA
Direct Drive System
Film Fill Media
All interior distribution piping is fabricated using standard PVC.
Water is evenly distributed over the fill media by removable ABS spray nozzles.
HOT WATER DISTRIBUTION SYSTEM
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
BENEFITS
BENEFITS
Direct-drive, with axial, sickle shaped type, adjustable-pitch fan blades.
Fabricated of corrosion resistant glass reinforced polyamide.
Operation temperature range : -50°F to 250°F.
Low noise emission.
High performance at lower speeds.
High strength due to its large cord.
The vertical inline recirculating pump is designed for optimum performance, easy installation and simplified maintenance.
The close-coupled design results in improved alignment and increased seal life. No isolation pads required.
OPTIONAL LOW NOISE FAN
RECIRCULATING PUMP
Recirculating Pump
Low Noise Fan
Copper is easy to work with, and has excellent thermal conductivity, corrosion resistance and durability.
Stainless steel casing.
Wide diagonal spacing for easy cleaning.
Type L copper.
Designed to block direct sunlight to the water, to minimize algae growth, reduce splash out and noise.
Fabricated from rigid, corrugated UV protected Polyvinyl Chloride (PVC); is easy removable to provide access for cleaning. Resistant to rot, fungi, bacteria and organic/inorganic acids and alkalis.
Meets CTI STD-136.
Flame spread rating is less than 20 according to ASTM E84, and self-extinguishing in less than 5 seconds according to ASTM D635.
COPPER COILS
AIR INLET LOUVERS
Durable, corrosion resistant copper coils.
Air Inlet Louvers
Manufactured of Polyvinyl Chloride (PVC); resistant to rot,
fungi, bacteria and organic/inorganic acids and alkalis
commonly found in cooling towers.
Meets CTI STD-136.
Fill media modules flame spread rating is less than 20
conforming to ASTM E84, and self-extinguishing in less
than 5 seconds conforming to ASTM D635.
Every tower is assembled and tested at the factory prior to shipment.
REYMSA has a deep commitment with customer satisfaction to build long term relationships.
FILM FILL MEDIA
Direct Drive System
Film Fill Media
All interior distribution piping is fabricated using standard PVC.
Water is evenly distributed over the fill media by removable ABS spray nozzles.
HOT WATER DISTRIBUTION SYSTEM
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
BENEFITS
REYMSA COOLING TOWERS, INC.
PRINCIPLE OF OPERATION
Hot recirculating water is distributed over the fill media through spray nozzles.
Tower Fans draw ambient air into the tower, making contact with water through the fill.
Heat Transfer takes place between the water and the air using latent and sensible cooling.
Water is distributed externally over the copper tube heat exchanger using gravity nozzles.
Process Fluid circulates internally through the copper tube heat exchanger.
Heat transfer occurs between the outside exposed water and the contained process fluid. Protecting the integrity of the process fluid.
1.-
2.-
3.-
4.-
5.-
6.-
REYMSA COOLING TOWERS, INC.
CONSTRUCTION DETAILS (FRONT OF THE TOWER)
Fan Section
Drift Eliminator
Spray Nozzle Manifold
Body Section
Cellular Fill
Air Inlet Louvers
Basin Section
Water distribution System
Process Fluid Inlet
Process Fluid Outlet
Copper Coil
Recirculating Pump
7.
8.
9.
10.
11.
12.
1.
2.
3.
4.
5.
6.
Water
REYMSA COOLING TOWERS, INC.
PRINCIPLE OF OPERATION
Hot recirculating water is distributed over the fill media through spray nozzles.
Tower Fans draw ambient air into the tower, making contact with water through the fill.
Heat Transfer takes place between the water and the air using latent and sensible cooling.
Water is distributed externally over the copper tube heat exchanger using gravity nozzles.
Process Fluid circulates internally through the copper tube heat exchanger.
Heat transfer occurs between the outside exposed water and the contained process fluid. Protecting the integrity of the process fluid.
1.-
2.-
3.-
4.-
5.-
6.-
REYMSA COOLING TOWERS, INC.
CONSTRUCTION DETAILS (FRONT OF THE TOWER)
Fan Section
Drift Eliminator
Spray Nozzle Manifold
Body Section
Cellular Fill
Air Inlet Louvers
Basin Section
Water distribution System
Process Fluid Inlet
Process Fluid Outlet
Copper Coil
Recirculating Pump
7.
8.
9.
10.
11.
12.
1.
2.
3.
4.
5.
6.
Water
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
GPM CAPACITY TABLE
CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)
CONSTRUCTION DETAILS (BACK OF THE TOWER)
Drain
Purge
Water Make up
Overflow
Access Doors
13.
14.
15.
16.
17.
CAPACITY TABLE
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
GPM CAPACITY TABLE
CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)
CONSTRUCTION DETAILS (BACK OF THE TOWER)
Drain
Purge
Water Make up
Overflow
Access Doors
13.
14.
15.
16.
17.
CAPACITY TABLE
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
ENGINEERING DATA & DIMENSIONS
CLOSED CIRCUIT FLUID COOLER (HFC-SERIES)
COIL PRESSURE DROP
CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)
* A Nominal TON is defined as 3 GPM of water cooled from 95°F to 85°F with a 78°F entering wet bulb.
ENGINEERING DATA & DIMENSIONSCOIL PRESSURE DROP
w
H
L
L L
w
H
L
w
L
H
L
A B
C
A A A A A
REYMSA COOLING TOWERS, INC. REYMSA COOLING TOWERS, INC.
ENGINEERING DATA & DIMENSIONS
CLOSED CIRCUIT FLUID COOLER (HFC-SERIES)
COIL PRESSURE DROP
CLOSED CIRCUIT FLUID COOLER(HFC-SERIES)
* A Nominal TON is defined as 3 GPM of water cooled from 95°F to 85°F with a 78°F entering wet bulb.
ENGINEERING DATA & DIMENSIONSCOIL PRESSURE DROP
w
H
L
L L
w
H
L
w
L
H
L
A B
C
A A A A A
REYMSA COOLING TOWERS, INC.
Toll Free Number 1-866-445-2043
1641 World Trade Center, Millennium Industrial Park Laredo, Tx. 78045
Phone (210) 579-4837 Fax (210) 745-1513
[email protected] www.reymsa.com