Clipsal C-Bus

144
Innovative control solutions Commercial or residential environments C-Bus Product Overview Catalogue

description

C-Bus information

Transcript of Clipsal C-Bus

Page 1: Clipsal C-Bus

Innovative control solutions Commercial or residential environments

C-BusProduct Overview Catalogue

Page 2: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue2

Clipsal Integrated SystemsOverview

As a company and brand, Clipsal has continuously developed and evolved to meet the needs of commercial and domestic building electrical requirements. Development in building automation products led to the formation of CIS (Clipsal Integrated Systems) in 2000, a business unit specialising in the manufacture of electronic lighting control and building automation products. Since then CIS has grown rapidly, gaining widespread acceptance in major commercial and domestic markets.

Through extensive research and design, CIS developed the C-Bus® Energy and Lighting Management System in 1994, and since then C-Bus has become the cornerstone of the CIS product range. Initially, C-Bus was designed and manufactured for commercial building applications. However, due to increasing worldwide interest, C-Bus was adapted to suit the domestic market with the release of C-Bus DIN Rail Series and associated products.

With the development of C-Bus for domestic application, a new generation of products was born, including the C-Touch™ Touch Screen Controllers, Neo® Wall Switches, and Saturn™ Wall Switches.

CIS continue to set new precedents by expanding the C-Bus range. Introducing products such as the modular Architectural and Professional ranges of high powered dimmers, C-Bus Wireless Technology, Dynamic Labelling Technology (DLT™), C-Bus Multi-Room Audio System and Wiser™ Home Control. Not only is the C-Bus product range extensive, but it also complies with international product certification requirements such as the C-Tick, CE and UL marks. All C-Bus products are developed to be backward compatible to ensure extensions of existing installations are easy, and capable of engaging these future technologies. C-Bus also assists with energy management through the control of lighting and electrical products to only use energy when required.

CIS have also recognised the changing requirements for control systems in commercial buildings, particularly with regards to the need to provide clients with one integrated control solution. CIS have created interface platforms for C-Bus, such the BACnet Gateway, DALI Gateway and OPC Server, to meet this integrated solution need.

CIS is committed to ensuring the end-user gets the most out of every C-Bus system. To assist in meeting this commitment, CIS has created the following C-Bus installer programs.

Established in 1920, Clipsal by Schneider Electric is Australia’s number one brand of electrical products, accessories and solutions for the residential, commercial, industrial, data, home control and energy management markets. Clipsal has evolved and grown from its Adelaide base with great success by supporting the local economy and providing products manufactured at multiple sites across Australia. Clipsal is an electrical industry leader, dedicated to supplying you with the most innovative and sustainable solutions available. As part of Schneider Electric, the global specialist in energy management, Clipsal provides a total electrical solution for any project or application.

Page 3: Clipsal C-Bus

3

APPROVED INSTALLER

C-Bus® Approved Installer Program

C-Bus® Approved Installers have been trained and accredited by Clipsal as specialists in C-Bus technology and its application. This is the first stage in the C-Bus accreditation process and can lead to pointOne or Platium partner status.

From system design through to installation, then on to programming and commissioning, a C-Bus Approved Installer will ensure that your C-Bus system reaches its full potential, delivering the best performance, functionality and, most of all, value for money.

Any building, whether it’s a home or a commercial site, is a big investment. Don’t risk compromising the outcome with just anyone. Insist on a C-Bus Approved Installer and get confidence and peace of mind in knowing that you have the backing of Clipsal, Australia’s number one in electrical building products.

C-Bus® pointOne Program

C-Bus® pointOne is a group of specialist systems integration companies that have the technical knowledge and practical experience on a whole range of complementary technologies to enhance the functionality of your residential premises. The one point of contact, C-Bus pointOne members make residential lighting control and automation applications an easier process. They do this by providing turnkey solutions for the design, project management, installation, integration, programming and support of Clipsal C-Bus, as well as integration with products from third party manufacturers.

C-Bus pointOne members are accredited integration professionals, who have been trained in all aspects of the Clipsal C-Bus system, with some having over 30 years of industry experience.

C-Bus® Platinum Program

The aim of the C-Bus Platinum Program is to link Clipsal clients who have a commercial building project to a network of professionals who are able to successfully deliver a complete C-Bus Control and Management System, including integration to other building services. From design to integration, installation and programming, C-Bus Platinum partners can assist commercial developers, consultants and designers throughout the project delivery process. This ensures a smooth delivery process with the highest quality C-Bus installation for your commercial building.

Page 4: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue4

Clipsal C-Bus Overview

Introduction

The Clipsal C-Bus system is a microprocessor based wiring system to control lighting and other electrical services.

From ON/OFF control of a lighting circuit to analogue type control, such as dimming electronic fluorescent ballasts, C-Bus can control and automate virtually any type of electrical load.

C-Bus information is held within individual C-Bus units rather than one central point. This ensures optimum communications speed and reliability.

To ensure fast and reliable operation, each device has its own in-built microprocessor, which can be individually programmed via ‘point and click’ PC-based software, or via ‘Learn Mode’ which doesn’t require a PC.

While a computer is unnecessary for normal C-Bus operation, C-Bus PC-based control and management software is available and provides additional flexibility to clients requiring this type of control.

Clipsal C-Bus is suitable for a wide range of applications.

Commercial Lighting Control

• Fluorescent lighting control for energy cost savings in high rise buildings.

• Integration with occupancy sensors and daylight level sensors, for energy efficiency.

• High-bay control in warehouses for energy cost saving.

• Integration with BMS to provide a more comprehensive lighting control solution.

Mood Lighting in Restaurants and Retail Outlets

• Flexible and integrated control of lighting and audiovisual equipment in boardrooms. Architectural lighting control for hotel foyers, ballrooms, art galleries and museums.

Standalone Room Control

• Integrated automation via touch screen user interfaces. For conference rooms and home theatres.

• Multiple scene/mood setting.

Residential Home Control

• Home entertainment - Integrated audiovisual, lighting control and other electrical services.

• Security - Integrated security, lighting and other electrical services.

• Comfort – Dimming, scene setting, etc.

• Convenience – Multiple point control, central point control from touch screens, automated time- based control, automated ‘Goodbye’ and ‘Welcome Home’ scenes.

• Energy efficiency – Incorporation of light level sensors, occupancy control, temperature sensors and much more to assist your home to operate more efficiently.

Page 5: Clipsal C-Bus

5

C-Bus Network Design Considerations

• Up to 1000m of C-Bus Cat. 5 UTP cable may be connected to a single C-Bus network

• Up to 100 C-Bus units may be connected to a single C-Bus network

• Where more than 1km and/or 100 standard C-Bus units are required, two or more networks can be created and linked with C-Bus Network Bridge and/or C-Bus Ethernet Interface Units

• Maximum number of networks in one installation is 255 (this limitation does not apply if a C-Bus Ethernet interface is utilised, the system size is then limited to IP addressing only)

• Maximum number of networks connected in series to the local network via Network Bridges is seven (i.e. using six network bridges)

• Each standard C-Bus unit requires 18mA @ 36V d.c. to operate correctly. Some C-Bus units, for example 5500PC, require 32mA. Some C-Bus units, for example L5508DIA, are self-powering and do not sink current from the 36V d.c. C-Bus network

• More than one C-Bus power supply can be connected to a C-Bus network to provide sufficient power to the C-Bus units. The C-Bus power supplies will share the load evenly. Maximum total power supply allowed is 2,000mA (2A)

• Any combination of power supply units is allowed as long as the total power available is 2,000mA or less

• Each C-Bus network requires only one network burden. This network burden is software selectable on C-Bus output units

• Each C-Bus network requires at least one system clock-generating unit (for data synchronisation)

• C-Bus power supply units may be connected to different phases

• Individual relay channels may be connected to different phases

• On L5508D1A and L5504D2A units the mains supply to the units power supply and the mains supply to the output channels must be on the same phase

• The isolation between the mains supply circuitry and the 36V d.c. C-Bus circuitry is greater than 3.75kV. This is achieved using double wound transformers and opto isolators. This means the C-Bus wiring, connections and circuitry can be considered extra low voltage

• C-Bus Cat. 5 UTP cable has mains rated sheathing, which means the C-Bus cable can be taken inside electrical distribution boards, provided segregation requirements of local wiring standards are met

• The following are control methods that provide a number of options when either manual or override control of electrical loads connected to a C-Bus network is required:

Manual toggle of output channels using the manual override buttons on output units

Remote ON/OFF override of a C-Bus network using standard 30 mechanism switches

Auto remote ON override of a C-Bus network using the C-Bus Network Monitor (5500NMA)

• All C-Bus output units consist of electronic components that may be damaged by surges, short circuits and over-voltages. All equipment should have over-current protection relevant to installed equipment and cable size, and surge protection fitted.

Page 6: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue6 Clipsal C-Bus Product Overview Catalogue6

Page 8 C-Bus Input Units Wall Switches, General Input Units, Passive Infrared Motion Detectors, Infrared Receivers, Remote Controls, Touch Screen Controllers

Page 46 C-Bus Output Units Architectural Dimmers, Professional Dimmers, DIN Rail Dimmers, Infrared Output Units, DIN Rail Relay Units, Standard Relay Units

Page 70 C-Bus System Units and Accessories Wiser Home Controller, Power Supply, Network Bridge, Network Interface, Gateways

Page 82 C-Bus Software Commissioning Tools, User Interfaces, Gateways and Drivers

Page 88 C-Bus Multi-Room Audio Matrix Switcher, Zone Amplifiers, Speakers

Page 98 C-Bus Wireless Wall Switches, Plug Adaptors, Remote Controls, Wireless Gateway

Page 120 C-Bus HomeSafe Security Interface

Page 122 C-Bus Typical Schematics

Contents

Page 7: Clipsal C-Bus

77

Wall Switches Occupancy Sensors

Environment Sensors

Touch Screen Controllers

General Input Units

Handheld IR Remotes

C-Bus HomeSafe Security Interface

Matrix Switcher Amplifiers Speakers

Commissioning Tools

Graphical User Interfaces

Gateways and Drivers

Network Support DevicesControllers Gateways

Professional Dimmers

DIN Rail Dimmers

DIN Rail Relays

Extra Low Voltage Relay

Infrared Transmitters

Wall Switches Plug Adaptors GatewaysHandheld Remotes

Page 8: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue8

C-Bus Enhanced Dynamic Labelling Technology (eDLT) Wall Switch

• Quick and easy installation

• Plug-in C-Bus fly lead

• Magnetic attachment to a custom mounting plate installed to standard mounting hardware (with 84mm centres)

• Can be secured to mounting plate with screws

• Proximity sensing for wake up and control functions (max. 5cm)

• 5 buttons with tri-colour LED indicators

• Backlit colour LCD screen

• 2.8” WQVGA TFT screen supports selected number of background and foreground colours

• Coloured LED indicators or backgrounds can provide status feedback for C-Bus events such as power monitoring or security system state

• Up to 4 pages with control of up to 16 devices

• 5-button single-page option

• Dual-action buttons provide intuitive control with left/right rocking action

• Use 1 dual-action button for easy UP/DOWN control of: o lighting levels o audio volume, bass and treble levels o motorised blinds, shutters, curtains, etc.

• Use 1 dual-action button for easy LEFT/RIGHT control of: o ceiling sweep fans o scene cycling o page navigation o C-Bus Multi-Room Audio source selection and radio station selection.

C-Bus Input UnitsWall Switches

• Native support for C-Bus Audio and C-Bus Measurement Applications: o enhanced performance with C-Bus Multi-Room Audio o display temperature from C-Bus Digital Temperature Sensor o display power usage and other text-based information.

• Range includes both Saturn and Neo fascia styles: o Saturn glass and metal fascias o Saturn style with either Black or White grid

• Room Courtesy Panel option utilising custom-made button caps

• Comprehensive “Tools” page allows a user to: o edit button labels o edit timer durations o change time and date settings o modify LED indicator on/off colours o modify screen background and foreground colours.

• Supports extended character sets for many languages

• Field upgradeable firmware

• C-Bus Toolkit programming enhancements

o WYSIWYG (what you see is what you get) interface o Intelligent algorithm improves programming time

• Fly lead and mounting plate are supplied with the eDLT and are also available separately

Page 9: Clipsal C-Bus

9

eDLT - Neo Series

Neo White (5055EDL-WE)

Neo Black (5055EDL-BK)

Neo Battleship Grey/Brushed Aluminium (5055EDL-GB)

AVAILABLE COLOURS

eDLT - Saturn Series

Saturn Pure White (5085EDLx-PW)

Saturn Ocean Mist (5085EDLx-OM)

Saturn Espresso Black (5085EDLx-EB)

Saturn Cream* (5085EDLx-CM)

Saturn Mid-Brown (5085EDLx-BR)

Saturn Stainless Steel (5085EDLx-SS)

Saturn Horizon Black (5085EDLx-HB) Note: ‘x’ denotes Black (B) or White (W) grid. ‘*’ denotes a product that is made to order.

C-Bus Input UnitsWall Switches

5085EDLB-HBWall Switch, 5-Button, eDLT

Pictured: Horizon Black

5000MPMounting Plate to suit eDLT Wall Switch

5085EDLW-PWWall Switch, 5-Button, eDLT

Pictured: Pure White

5085EDLB-EBWall Switch, 5-Button, eDLT

Pictured: Espresso Black

5085EDLB-SSWall Switch, 5-Button, eDLT

Pictured: Stainless Steel

5000CBFPlug-in C-Bus Fly Lead Terminal

5085EDLB-OMWall Switch, 5-Button, eDLT

Pictured: Ocean Mist

Page 10: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue10

AVAILABLE COLOURS

DLT - Neo Series

Neo White (5055DL-WE)

Neo Battleship Grey/Brushed Aluminium

(5055DL-GB)

C-Bus Dynamic Labelling Technology (DLT) Wall Switches

• Available in Saturn and Neo styles

• Saturn units feature an impact resistant glass fascia available in Pure White, White, Black, Cream and Mid-Brown

• Saturn unit available with Stainless Steel fascia

• Neo units available in grey with Brushed Aluminium-look inner surround

• Units incorporate 8 buttons for C-Bus Group/Scene control over 2 pages (4 buttons per page)

• Page/Scroll button

• Each button can be programmed with ON/OFF toggle, dimmer, timer, scene control and custom functions

• LCD labelling for each button

• Text, sliders and bitmaps can be defined and downloaded to the unit via a C-Bus network.

• Dimmable blue LED on each button

• Night light on all buttons or just the bottom button

• 64 x 128 pixel LCD screen

• Dimmable white LED backlighting for the LCD

• Ignore first button press option

• Fall back to page 1 option

• Real-time clock display

• Programmed via C-Bus Toolkit software

• Draws 22mA from the C-Bus network

• C-Bus Learn Enabled

C-Bus Input UnitsWall Switches

Neo Series

5055DL-WEWall Switch, 5-Button, DLT

Pictured: White

5055DL-GBWall Switch, 5-Button, DLT

Pictured: Battleship Grey/Brushed Aluminium

Page 11: Clipsal C-Bus

11

AVAILABLE COLOURS

DLT - Saturn Series

Saturn White (5085DL-GF)

Saturn Pure White (5085DL-PW)

Saturn Mid-Brown (5085DL-780)

Saturn Black (5085DL-680)

Saturn Stainless Steel (5085DL-J80)

Saturn Cream (5085DL-380)

Saturn Horizon Black (5085DL-HB)

5085DL-680Wall Switch, 5-Button, DLT

Pictured: Black

5085DL-GFWall Switch, 5-Button, DLT

Pictured: White

Saturn Series

5085DL-J80Wall Switch, 5-Button, DLT

Pictured: Stainless Steel

5085DL-PWWall Switch, 5-Button, DLT

Pictured: Pure White

5085DL-HBWall Switch,5-Button, DLT

Pictured: Horizon Black

5085DL-780Wall Switch, 5-Button, DLT

Pictured: Mid-Brown

5085DL-380Wall Switch, 5-Button, DLT

Pictured: Cream

C-Bus Input UnitsWall Switches

Page 12: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue12

5086NL-680Wall Switch, 6-Button

Pictured: Black

5084NL-PWWall Switch, 4-Button

Pictured: Pure White

5082NL-J80Wall Switch, 2-Button

Pictured: Stainless Steel

C-Bus Saturn Wall Switches

• Impact-resistant glass fascia, available in Pure White, White, Black, Cream and Mid-Brown

• Available with Stainless Steel fascia

• 2, 4 or 6 buttons per wall switch

• Programmable as ON/OFF toggle, dimmer, timer, scene control and custom functions

• Selectable blue and orange LED indicator on each button configured through C-Bus Toolkit software

• LED button indicators provide illumination and status feedback

• Night light feature

• Fallback level option to dim indicators at a set time after the last button press

• Mounted using standard mounting accessories (ordered separately)

• Programmed via Learn mode or the C-Bus Toolkit software

• Draws 22mA from the C-Bus network

• C-Bus Learn Enabled

C-Bus Input UnitsWall Switches

AVAILABLE COLOURS

Saturn Series

Saturn Stainless Steel (508xNL-J80)

Saturn Pure White (508xNL-PW)

Saturn Black (508xNL-680)

Saturn White (508xNL-GF)

Saturn Cream (508xNL-380)

Saturn Mid-Brown (508xNL-780)

Note: ‘x’ denotes number of buttons: i.e. 2, 4 or 6 buttons.

Page 13: Clipsal C-Bus

13

C-Bus Input UnitsWall Switches

5080LC-8Pre-Labelled Button Caps (individually printed with commonly used labels and come in pack of 66)

C-Bus Saturn Wall Switches - Accessories

5850F-WEMounting Frame, Rectangular,White (pack of 5), suits 2-, 4- or 6-Button Wall Switches.

This mounting frame accessory can be used in conjunction with C-Bus Saturn Wall Switches to provide an alternative look to the switch edge for blending in with the client’s wall colour.

1.

2. 3.

Mounting Frames

Page 14: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue14

LHC882-WHWall Switch, 2-Button

Pictured: White

LHC884-BKWall Switch, 4-Button

Pictured: Black

LHC886-WHWall Switch, 6-Button

Pictured: White

C-Bus Modena Wall Switches

• Available in White (WH) and Black (BK)

• 2, 4 or 6 buttons per wall switch

• Programmable as ON/OFF toggle, dimmer, timer, scene control and custom functions

• Selectable blue and orange LED indicator on each button configured through C-Bus Toolkit software

• LED button indicators provide illumination and status feedback

• Night light feature

• Fallback level option to dim indicators at a set time after the last button press

• Mounted using standard mounting accessories (ordered separately)

• Programmed via Learn mode or the C-Bus Toolkit software

• Draws 22mA from the C-Bus network

• C-Bus Learn Enabled

• Suits Modena 8000 Series Surrounds

C-Bus Input UnitsWall Switches

AVAILABLE COLOURS

Modena Series

White (LHC88x-WH)

Black (LHC88x-BK)

Note: ‘x’ denotes number of buttons: i.e. 2, 4 or 6 buttons.

Modena 8000 Series Surrounds

Platinum (M8000HC-PT)

Charcoal (M8000HC-CC)

Blue (M8000HC-DB)

Red (M8000HC-RD)

Champagne (M8000HC-CP)

Gunmetal (M8000HC-GM)

Chrome (M8000HC-CH)

Page 15: Clipsal C-Bus

15

C-Bus Input UnitsWall Switches

C-Bus Avanti Wall Switches

• Rockers are a long throw momentary action type (‘spring return’)

• Available in 1, 2 or 3 buttons per wall switch in White only

• Programmable as ON/OFF toggle, dimmer, timer, scene control and custom functions

• Selectable red and green LED indicator on each button configured through C-Bus Toolkit software

• LED button indicators provide illumination and status feedback

• Night light feature

• Fallback level option to dim indicators at a set time after the last button press

• Mounted using standard mounting accessories (ordered separately)

• Programmed via Learn mode or the C-Bus Toolkit software

• Draws 18mA from the C-Bus network

• C-Bus Learn Enabled

5093NL-WEWall Switch, 3-Button

Pictured: White

5092NL-WEWall Switch, 2-Button

Pictured: White

5091NL-WEWall Switch, 1-Button

Pictured: White

AVAILABLE COLOURS

White (509xNL-WE)

Avanti Series

Note: ‘x’ denotes number of buttons: i.e. 1, 2 or 3 buttons.

Page 16: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue16

C-Bus Neo Wall Switches

• Architecturally designed, modular C-Bus Wall Switches

• Optional rocker cover with ID window for labelling of buttons (ordered separately)

• Backlight for ID windows

• 2, 4 or 8 buttons per wall switch

• Integral infrared receiving window

• Programmed via C-Bus installation software or via the Learn mode features

• Programmed as dimmers, timers, ON/OFF toggle switches and scene switches (up to four scenes per unit)

• Selectable blue and orange button LEDs configured through C-Bus installation software

• Available as standard in Battleship Grey (GB), White Electric (WE), Cream (CM), Soft Grey (SG) and Black (BK)

• Night light feature

• Units use standard Australian mounting brackets and wall boxes

• Units draw 22mA from a C-Bus network

• C-Bus Learn Enabled

C-Bus Input UnitsWall Switches

Page 17: Clipsal C-Bus

17

5052NRI - GBNeo Rocker Cover with ID Window (pack of 10)

Pictured: Battleship Grey/Brushed Aluminium

C-Bus Neo Wall Switches - Accessories

5038TX28-Button Handheld Infrared Remote Control for Neo Switches (also suits C-Bus 30M Wall Switches, C-Bus Multi-Sensor and 503xNIRL Series Wall Switches)

5054NL-CMWall Switch, 4-Button

Pictured: Cream

5052NL-GBWall Switch, 2-Button

Pictured: Battleship Grey/Brushed Aluminium

5058NL-WEWall Switch, 8-Button

Pictured: White

C-Bus Input UnitsWall Switches

AVAILABLE COLOURS

Neo Series

Battleship Grey/Brushed Aluminium (505xNL-GB)

Cream (505xNL-CM)

White (505xNL-WE)

Soft Grey (505xNL-SG)

Black (505xNL-BK)

Note: ‘x’ denotes number of buttons: i.e. 2, 4 or 8 buttons.

Page 18: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue18

C-Bus Reflection Wall Switches

• Architectural, flat stainless steel C-Bus Wall Switches

• No visible screws

• 1, 2, 3, 4, 6 or 8 buttons per wall switch

• Available in brushed Stainless Steel

• Each button has an associated blue LED indicator providing feedback status

• Programmed as dimmers, timers, ON/OFF toggle switches and scene switches (up to 4 scenes per unit)

• Programmed via C-Bus installation software or via the Learn mode features

• A custom wall box is required to mount this switch, standard wall brackets and boxes cannot be used

• Units draw 22mA from a C-Bus network

• C-Bus Learn Enabled

C-Bus Input UnitsWall Switches

Page 19: Clipsal C-Bus

19

R5061NLWall Switch, 1-Button

Pictured: Stainless Steel

R5062VNLWall Switch, 2-Button

Pictured: Stainless Steel

R5063NLWall Switch, 3-Button

Pictured: Stainless Steel

R5064VNLWall Switch, 4-Button

Pictured: Stainless Steel

R5066NLWall Switch, 6-Button

Pictured: Stainless Steel

R5068NLWall Switch, 8-Button

Pictured: Stainless Steel

C-Bus Reflection Wall Switches - Accessories

R5060WBWall Box to suit Reflection Range of Wall Switches

Important note: Wall Box must be used to install ReflectionWall Switches.

C-Bus Input UnitsWall Switches

AVAILABLE COLOURS

Reflection Series

Stainless Steel (R506xyNL)

Note: ‘x’ denotes number of buttons: i.e. 1, 2, 3, 4, 6 or 8 buttons. ‘y’ denotes vertical orientation. (Applicable to 2 and 4 button options).

Page 20: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue20

C-Bus Standard Series Wall Switches

• May be programmed as dimmers, timers and ON/OFF toggle switches

• 1, 2 or 4 buttons per wall switch

• Each unit features a programmable status indicator

• Units draw 18mA from a C-Bus network

• C-Bus Learn Enabled

• Slimline and Eclipse Series are available with either orange or blue LED indicators

C-Bus Input UnitsWall Switches

Page 21: Clipsal C-Bus

21

C-Bus Input UnitsWall Switches

5031NLWall Switch, 1-Button, Orange LED

Pictured: White

C5031NLWall Switch, 1-Button, Orange LED

Pictured: White

SC5031NLWall Switch, 1-Button, Orange LED

Pictured: White

SL5031NLWall Switch, 1-Button, Orange LED

Pictured: White

White (503xNL-WE)

Cream (503xNL-CM)

Black (503xNL-BK)

Desert Sand (503xNL-DS)

Soft Grey (503xNL-SG)

AVAILABLE COLOURS

Classic C2000 Series

2000 Series

Eclipse SL2000 Series

Slimline SC2000 Series

White (C503xNL-WE)

Cream (C503xNL-CM)

Black (C503xNL-BK)

Desert Sand (C503xNL-DS)

Soft Grey (C503xNL-SG)

White (SC503xNL-WE)

Cream (SC503xNL-CM)

Black (SC503xNL-BK)

Desert Sand (SC503xNL-DS)

Soft Grey (SC503xNL-SG)

White (SL503xNL-WE)

Cream (SL503xNL-CM)

Black (SL503xNL-BK)

Desert Sand (SL503xNL-DS)

Soft Grey (SL503xNL-SG)

Note: ‘x’ denotes number of buttons: i.e. 1, 2 or 4 buttons.

Page 22: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue22

C-Bus Metal Plate and Multi-Gang Wall Switches

• May be programmed as dimmers, timers and ON/OFF toggle switches

• Each button features a programmable LED status indicator

• Available in Stainless Steel and Brass finishes

• The buttons are available in White or Black

• Wall boxes are supplied when ordering 8-button or higher configurations

• Each 4-button unit array draws 18mA from a C-Bus network

• C-Bus Learn Enabled

C-Bus Input UnitsWall Switches

Page 23: Clipsal C-Bus

23

‘A’ Style Deep Curved Plate, Brass

BA5031NLWall Switch, 1-Button

BA5032NLWall Switch, 2-Button (Pictured)

BA5034NLWall Switch, 4-Button

‘B’ Style Flat Plate,Brass

BB5031NLWall Switch, 1-Button

BB5032NLWall Switch, 2-Button (Pictured)

BB5034NLWall Switch, 4-Button

‘B’ Style Brass Flat Plate

5008B164/3LWall Switch, 8-Button 5012B164/4LWall Switch, 12-Button 5020B164/7LWall Switch, 20-Button 5024B164/8LWall Switch, 24-Button, Horizontal (Pictured)

C-Bus Input UnitsWall Switches

‘A’ Style Deep Curved Plate,Stainless Steel

A5031NLWall Switch, 1-Button

A5032NLWall Switch, 2-Button (Pictured)

A5034NLWall Switch, 4-Button

‘B’ Style Flat Plate,Stainless Steel

B5031NLWall Switch, 1-Button

B5032NLWall Switch, 2-Button (Pictured)

B5034NLWall Switch, 4-Button

‘B’ Style Stainless Steel Flat Plate

5008S164/3LWall Switch, 8-Button 5012S164/4LWall Switch, 12-Button 5016S164/6LWall Switch, 16-Button, Horizontal 5016S162/3LWall Switch, 16-Button, Vertical 5020S164/7LWall Switch, 20-Button 5024S164/8LWall Switch, 24-Button, Horizontal (Pictured)

AVAILABLE COLOURS

White (WE)

Black (BK)

Buttons

Page 24: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue24

C-Bus Input UnitsWall Switches

C-Bus 30 Mechanism Wall Switches

• Mounts into any Clipsal grid plate with a 30M aperture (ordered separately). See figures 1 and 2.

• Available in master and slave mechanisms

• Master mechanism can accommodate up to 3 slaves

• Master available in IR or non-IR variants

• Programmable as ON/OFF toggle, dimmer, timer, scene control and custom functions

• Selectable blue and orange LED indicator configured through C-Bus Toolkit software

• LED button indicator provides illumination and status feedback

• Night light feature

• Fallback level option to dim indicator at a set time after the last button press

• Programmed via Learn mode or the C-Bus Toolkit software

• Draws 18mA from the C-Bus network

• Labelling option for each button

• Available in White only

• C-Bus Learn Enabled

1.

2.

Page 25: Clipsal C-Bus

25

AVAILABLE COLOURS

White

C-Bus 30 Mechanism Wall Switches - Accessories

5038TX2C-Bus 30M 8-Button, Handheld Infrared Remote Control, for C-Bus 30M Switches (also suits Neo Wall Switches, C-Bus Multi-Sensor and 503xNIRL Series Wall Switches)

C-Bus Input UnitsWall Switches

5031NMMIRL30M Wall Switch Master + IR, White

5031NMML30M Wall Switch Master, White

5031NMS30M Wall Switch Slave, White

Page 26: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue26

C-Bus Single-Zone Thermostat

• Single-zone C-Bus thermostat

• Wall-mounted

• Dimensions 92mm x 127mm x 24mm

• Support for control of HVAC equipment via C-Bus or the internal HVAC relays

• Manually adjustable temperature set point and mode of operation (heating, cooling or ventilation)

• The unit includes fan speed control and a Setback mode

• Easy to use operator interface includes an integral LCD to display the current temperature and mode of operation

• Draws 40mA from a C-Bus network

5070THBRC-Bus Thermostat, Programmable, Single-Zone with 5 Relays (relays for HVAC plant control only, not accessible via C-Bus)

5070THBC-Bus Thermostat, Programmable, Single-Zone, (no onboard HVAC plant control relays)

C-Bus Input UnitsGeneral Input Units

AVAILABLE COLOURS

Saturn Style

White (5070THxyPG-WE)

Black (5070THxy-BK)

Stainless Steel (5070THxy-SS)

Note: ‘x’ denotes basic (B) or programmable (P). ‘y’ denotes relays onboard (R).

Page 27: Clipsal C-Bus

27

5070THPRC-Bus Thermostat, Programmable, 4-Zone, with 5 Relays (relays for HVAC plant control only, not accessible via C-Bus)

5070THPC-Bus Thermostat, Programmable, 4-Zone (no onboard HVAC plant control relays)

C-Bus 4-Zone Thermostat with Programmable Time Scheduling

• 4 zones (plus the common zone), programmable C-Bus Thermostat

• Wall-mounted

• Dimensions 105mm x 149mm x 24mm

• Support for control of HVAC equipment via C-Bus or directly using onboard HVAC relays

• Manually adjustable temperature set point, mode of operation (heating, cooling or ventilation) and time schedules

• Onboard 7-day HVAC time scheduling (user programmable), manual fan speed control and Setback mode

• Easy to use interface, comprising an LCD, manual control buttons and a rotating dial with an integral push-button

• Draws 40mA from a C-Bus network

C-Bus Input UnitsGeneral Input Units

AVAILABLE COLOURS

Saturn Style

White (5070THxyPG-WE)

Black (5070THxy-BK)

Stainless Steel (5070THxy-SS)

Note: ‘x’ denotes basic (B) or programmable (P). ‘y’ denotes relays onboard (R).

Page 28: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue28

C-Bus Input UnitsGeneral Input Units

5504GIGeneral Input Unit, 4-Channel

C-Bus General Input Unit

• 4-channel general analogue/digital input unit, DIN rail mounted

• 8M DIN modules wide

• Dimensions 144mm x 85mm x 65mm

• Used to interface a C-Bus system to third party products, such as light level sensors, current sensors, temperature sensors, CO2 detectors, differential sensors, pressure sensors, flow rate sensors, moisture probes, etc.

• Designed to either trigger the state of a C-Bus group address as a function of input level or broadcast a message on the C-Bus network, representing the input level

• Maximum of 10 units on a single C-Bus network

• Can be used to measure analogue values (0–1V, 0–5V, 0–10V, 0–20V, 0–20mA, 4–20mA, 500 ohm, 1k ohm, 3k ohm and 10k ohm thermistor inputs)

• Requires a 24V d.c. connection (power pack included)

• Units draw 18mA from a C-Bus network

5104BCLBus Coupler Input Unit, 4-Channel

C-Bus Bus Coupler

• 5104BCL used to interface up to 4 standard voltage- free mechanical switches, including latching and toggle switches to C-Bus

• 5104BCL supports onboard scenes

• 5102BCLEDL used to interface up to 2 standard voltage free mechanical switches, including latching and toggle switches to C-Bus, incorporates remote LED facility

• Dimensions 55mm x 49mm x 18mm

• The unit is designed to fit into a standard wall box

• Each unit features a programmable status indicator

• The maximum distance between the unit and an external voltage free switch is limited to 1 metre (use L5504AUX if longer distance required)

• Units draw 18mA from a C-Bus network

• C-Bus Learn Enabled

5102BCLEDLBus Coupler Input Unit, 2-Channel, with Remote LED Facility

Page 29: Clipsal C-Bus

29

C-Bus DIN Rail-Mounted Auxiliary Input Unit

• 4-channel auxiliary input module, DIN rail-mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Permits voltage-free switches to be connected to C-Bus, such as Clipsal 30 Series Mechanisms, limit switches and weatherproof switches

• Each unit features a programmable status indicator

• The unit may be programmed in the same way as a wall switch, to achieve the same functions such as timer, dimmer or toggle switches

• Draws 18mA from a C-Bus network

• C-Bus Learn Enabled

L5504AUXAuxiliary Input Module, 4-Channel

C-Bus Input UnitsGeneral Input Units

Page 30: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue30

C-Bus Input UnitsGeneral Input Units

C-Bus Digital Temperature Sensor Input Unit and Sensors

• 4-channel Digital Temperature Sensor Input Unit

• 1 Digital Temperature Sensor per input channel (empty channels are permitted)

• Digital Temperature Sensors

• 3 temperature sensor types: o FLAT tip, 4.5mm (W) x 7mm (H) x 20mm (L) o TUBE tip, 6mm (dia.), 30mm (L) o POINT tip, 6mm (dia.), 12mm (L).

• Temperature sensor cable is 2-conductor, insulated and 2m in length

• Temperature sensors are powered by the Input Unit

• Maximum extension length is 25m per temperature sensor

• Temperature sensor tip material – 314 grade stainless steel

• Input Unit contains LED indicators for temperature sensor connection status

• Input Unit detects reverse connection, short or open circuit and failure of connected temperature sensors

• Measurement range from -40°C to 100°C

• Temperature measurement resolution of 0.1°C

• Temperature measurement accuracy: o -40°C to -10°C: ±2°C o -10°C to 80°C: ±0.5°C o 80°C to 100°C: ±2°C.

• Operating temperature range of 0°C to 65°C

• Configurable frequency of temperature broadcast on C-Bus

• Temperature offset feature within programming

• Operates on C-Bus Measurement or C-Bus HVAC applications

• Unit draws 18mA from a C-Bus network

5104DTSIC-Bus Digital Temperature Sensor Input Unit, 4-Channel (sensors sold separately)

5100DTSFTemperature Sensor, FLAT Tip

5100DTSTTemperature Sensor, TUBE Tip

5100DTSPTemperature Sensor, POINT Tip

Page 31: Clipsal C-Bus

31

C-Bus Input UnitsGeneral Input Units

5754PEC-Bus Light Level Detector, 0–1500 lux, Surface Mount

5031PEWP-GYC-Bus Light Level Sensor, 40–1600 lux, Weatherproof, 56 Series

C-Bus Surface Mount Light Level Detector

• Used to measure and regulate lighting in the range of 0-1500 lux

• Programmable target light level and margin on installation

• Target light level and margin are adjustable from C-Bus (Surface Mount model only)

• Can be used to achieve bank switching or continuous dimming

• Available in outdoor weatherproof 56 Series Enclosure

• Units draw 15mA (Surface Mount) and 18mA (Weatherproof) from a C-Bus network

5031RDTSL-WEC-Bus Temperature Sensor, 0–50 Degrees Celsius, 2000 Series

C-Bus Temperature Sensor

• Used to measure and regulate either heating or cooling in the range 0–50 degrees celsius

• Digital sensor (doesn’t require calibration in the field)

• Programmable target temperature and margin on installation

• Programmable set back temperature for when room is unoccupied

• Broadcast of temperature over C-Bus network

• Adjustable temperature broadcast interval

• Temperature offset capabilities

• Provides additional zone sensors for the C-Bus 4-Zone Thermostat

• Units draw 18mA from a C-Bus network

Page 32: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue32

C-Bus Passive Infrared (PIR) Motion Detector - Outdoor

• C-Bus PIR Motion Detector suitable for outdoor use

• The unit has a field of view of 110° and a detection range which extends 18 metres

• The unit features a light threshold adjustment on the unit

• The time delay is programmable in the range: 1 second to 18 hours

• Features a Sunset Switch program

• Draws 18mA from a C-Bus network

5750WPL-GYC-Bus Motion Detector, Infrared, IP66, Outdoor

C-Bus Input UnitsGeneral Input Units

Field of View (At Maximum Sensitivity)

There may be noticeable differences in the range due to differing conditions (background temperature, speed of movement, types of clothing worn, etc.)

Ultra short zones nominal range 1.2m

Short range zones nominal range 4m

Intermediate zones nominal range 8m

Long zones nominal range 18m

Optimum ‘approach path’

Fields of view top elevation

Fields of view side elevation

18m

2.4m

Head vertical 5°

30°

110°

Page 33: Clipsal C-Bus

33

C-Bus Input UnitsGeneral Input Units

C-Bus Passive Infrared (PIR) Motion Detector - Indoor

• C-Bus PIR Motion Detector suitable for indoor use

• The unit has a coverage range of 6m x 6m and a field of view of 90°

• The unit features a light threshold adjustment on the unit

• The time delay is programmable in the range: 1 second to 18 hours

• Features a Sunset Switch program

• Draws 18mA from a C-Bus network

5751L-WEC-Bus Motion Detector, Infrared, Indoor, Corner Mount

Field of View

ceiling

floor

2.4m

8.5m approx. 6m x 6m approx.

Page 34: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue34

C-Bus Input UnitsGeneral Input Units

C-Bus Passive Infrared (PIR) Motion Detector - 360°

• Fush mount, 360°, ceiling mount PIR motion detector

• Suitable for indoor use

• The unit has a coverage range of 6m x 6m and a field of view of 360°

• The unit features a light threshold adjustment on the unit

• The time delay is programmable in the range 1 second to 18 hours

• Features a Sunset Switch program

• Draws 18mA from a C-Bus network

C-Bus Multi-Sensor

• Flush mount, 360°, ceiling mount multi-sensor

• Combined PIR motion detector, light level sensor and IR receiver

• Capable of controlling up to 8 C-Bus scenes or 8 C-Bus group addresses

• Supports the ‘corridor linking’ feature for commercial building applications

• Three LEDs indicate a range of actions from movement, to the receiving of IR commands and the device’s status

• Light and PIR sensitivity are set via adjustment screws located on the sensor unit

• Dual element detectors minimise false triggering

• An LED status indicator on the unit is used to report the current state of the load controlling device

• Draws 18mA from a C-Bus network

• C-Bus Learn Enabled

5753LC-Bus Motion Detector, Infrared, Indoor, Flush Mount, 360°

5753PEIRLC-Bus Multi-Sensor, Combined Motion Detector, Light Level Sensor and IR Receiver

Page 35: Clipsal C-Bus

3535

C-Bus Input UnitsGeneral Input Units

Field of View (5753L and 5753PEIRL)

8m (26ft)

6m (20ft)

4m (13ft)

2m (7ft)

0m (0ft)

2m (7ft)

4m (13ft)

6m (20ft)

8m (26ft)

12m (39ft)

10m (33ft)

6m (20ft)

2m (7ft)

0m (0ft)

2m (7ft)

6m (20ft)

10m (33ft)

12m (39ft)

3.7m (12ft)

2.4m (8ft) 2.7m

(9ft)3.0m (10ft)

Side View Ceiling

The 5753PEIRL IR Receiver range is 5m circular when using the 5088TX.

The stated field of view is typical for full body movement and is subject to variations caused by the type and quantity of clothing worn, as well as variable background temperature characteristics and speed of movement. Rapid and large temperature changes may be detected, even if they appear to be well beyond the field of view, due to reflections off surfaces that are within the field of view.

PIR Area of Detection (Side View)

Page 36: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue36

C-Bus Input UnitsGeneral Input Units

C-Bus Surface Mount Detectors

• Mounting solution suits surface mount applications

• Quickly mounts on solid surfaces such as masonry or wood

• Low-profile surface mount design – extends only 33mm from the mounting surface

• Uses passive infrared (PIR) detection with manually adjustable sensitivity to motion

• Software programmable time delay

• Motion detection coverage typically 7.6m diameter (at 2.7m mounting height)

• C-Bus control of light level target, light level margin, high/low lux levels and high/low thresholds

• Bank switching of lighting levels based upon the light level set point

• Daylight Harvesting to maintain a constant user-configured light level

• Infrared (IR) receiver for control from C-Bus Remote Control devices (5754ODPEIR only)

5754ODPEIRC-Bus 360° Occupancy and Light Level Detector with IR Receiver, Surface Mount

5754ODPEC-Bus 360° Occupancy and Light Level Detector, Surface Mount

Page 37: Clipsal C-Bus

37

C-Bus Input UnitsGeneral Input Units

Field of View (5754ODPEIR and 5754ODPE)

PIR Area of Detection (Top View)

PIR Area of Detection (Side View)

Minor motion 7.6m (25ft)

Major motion 9.7m (32ft)

2.7m (9ft)

30°

7.6m (25ft)

9.7m (32ft)

Page 38: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue38

C-Bus Occupancy Controllers and Detectors

• Perfect for occupancy detection in commercial applications

• Suitable for areas such as meeting rooms, stairwells, open plan office environments, car parks and washrooms

• Available in 1- or 2-zone models

• Wide range of PIR, ultrasonic and PIR/ultrasonic (Dual Technology) wall and ceiling mount detectors, with 110°–360° detection ranges

• Connect to up to three motion detectors per zone

• The C-Bus Occupancy Controller unit provides power to the detectors

• Segregated LV and ELV compartments

• Onboard 16A relay(s)

• Tested and rated to switch multiple mains phases

• Fully self-contained (cable directly to the unit)

• The occupancy controller is pre programmed and works out of the box

• Occupancy controllers function with or without a C-Bus connection

• Quick and easy to install

• Multiple mounting options (keyhole or hanging)

• Highly flexible advanced programming options including corridor linking and multiple join modes for meeting rooms

• Auxiliary inputs for standard Clipsal Switch types (push-button or toggle-type switches)

• Onboard timers (1 minute - 4 hours) and relay fail-safe mode

• Remote override ON/OFF capability

• C-Bus supply voltage: 15–36V d.c. @ 25mA (does not provide power for C-Bus network)

• Detector supply voltage: 24V d.c. 280mA (140mA per zone)

• 2-zone dimmer model provides control outputs for DSI, DALI (broadcast) or 010V analogue signals

C-Bus Occupancy Controllers

5752PP/1R1-Zone C-Bus Occupancy Controller with 1 Relay

5752PP/2R2-Zone C-Bus Occupancy Controller with 2 Relays

5752PP/2R/2D2-Zone C-Bus Occupancy Controller with 2 Relays and 2 Dimmer Outputs: DSI/DALI/0-10 V

C-Bus Input UnitsGeneral Input Units

Page 39: Clipsal C-Bus

39

C-Bus Input UnitsGeneral Input Units

752/CUCeiling Mount 360°, Ultrasonic Motion Detector

752/WPWall Mount 110°, PIR Motion Detector

752/CPCeiling Mount 360°, PIR Motion Detector

Occupancy Detectors

752/CDCeiling Mount 360°, PIR/Ultrasonic Motion Detector

Page 40: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue40

C-Bus Infrared (IR) Receivers

• Wall-mounted C-Bus IR Receiver incorporating 4 stations of IR receivers

• Available with or without C-Bus buttons

• May be programmed to achieve functions such as a dimmer, timer or toggle switch

• Units draw 18mA from a C-Bus network

• C-Bus Learn Enabled

• Status indicators

C-Bus Input UnitsGeneral Input Units

Page 41: Clipsal C-Bus

41

C-Bus Input UnitsGeneral Input Units

AVAILABLE COLOURS

Classic C2000 Series

2000 Series

White (C503xNIRL-WE)

Cream (C503xNIRL-CM)

Black (C503xNIRL-BK)

Desert Sand (C503xNIRL-DS)

White (SC503xNIRL-WE)

Cream (SC503xNIRL-CM)

Black (SC503xNIRL-BK)

Desert Sand (SC503xNIRL-DS)

White (SL503xNIRL-WE)

Cream (SL503xNIRL-CM)

Black (SL503xNIRL-BK)

Desert Sand (SL503xNIRL-DS)

White (503xNIRL-WE)

Cream (503xNIRL-CM)

Black (503xNIRL-BK)

Desert Sand (503xNIRL-DS)

C5031NIRL4-Channel Infrared Receiver Only

Pictured: White

C5034NIRL4-Channel Infrared Receiver with 4 Buttons

Pictured: White

5031NIRL4-Channel Infrared Receiver Only

Pictured: White

5034NIRL4-Channel Infrared Receiver with 4 Buttons

Pictured: White

SL5031NIRL4-Channel Infrared Receiver Only

Pictured: White

SL5034NIRL4-Channel Infrared Receiver with 4 Buttons

Pictured: White

Eclipse SL2000 Series

SC5031NIRL4-Channel Infrared Receiver Only

Pictured: White

SC5034NIRL4-Channel Infrared Receiver with 4 Buttons

Pictured: White

Slimline SC2000 Series

Note: ‘x’ denotes number of buttons: i.e. 1 (zero button) or 4 buttons.

Page 42: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue42

C-Bus Input UnitsRemote Controls

C-Bus Handheld Infrared Transmitters

• Saturn style

• Designed for use with C-Bus 30 Mechanism Wall Switches, C-Bus Neo Wall Switches, C-Bus Detectors (with IR Receiver) and the 503xNIRL Series Wall Switches

• 4- and 8-button units available

• Range of up to 15m (line of sight)

• Features IR bank selection switch with each group of 4 buttons assigned to either bank A/B or bank C/D

• The bank selection is changed by removing the back cover

Page 43: Clipsal C-Bus

43

5088TX8-Button C-BusInfrared Remote Control with Holder

5084TX4-Button C-BusInfrared Remote Control with Holder

5080TXCC-Bus Remote Control Holder (Spare)

C-Bus Input UnitsRemote Controls

Page 44: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue44

C-Bus Input UnitsTouch Screen Controllers

C-Touch 6.4” Colour Touch Screen Controllers

• Available in Saturn, Neo or Metal Series Surrounds

• 6.4” (diagonal), VGA, 640 x 480 pixels, colour LCD screen

• Displays pages of graphical items, such as buttons, sliders and images that perform C-Bus related functions when pressed

• Includes a real-time clock for automatic scheduling of events based on the time of day, week, month or year

• Controllable via an infrared handheld remote control unit

• Fully customised to suit user requirements via the included Windows™ compatible configuration software

• The software includes a logic engine module that allows the installer to program logic based (if-then-else) control into the touch screen configuration

• Connects directly to a C-Bus network (no external C-Bus PC Interface required)

• Control and monitor devices connected to C-Bus, Ethernet and RS-232 (custom Ethernet and RS-232 support via the included logic programming language)

• Unit programmable via an Ethernet connection

• Client/server plug-in for Windows Media Player

• Animated buttons with more than 256 animation frames supported

• Fully customisable graphics including bar graphs, sliders, percentage indicators, images, gauges and clocks with any border and background style

• Supports web page embedding

• Supports IP camera inputs

• Supports project theme templates

• Audio WAV file support

• Scene control

• Event scheduling support

• Irrigation control

• Password access control

• Dimensions: 246mm x 173mm x 72.5mm (excluding fascia)

• Cut-out size 208mm x 162mm

Page 45: Clipsal C-Bus

45

C-Bus Input UnitsTouch Screen Controllers

Saturn Series

Neo Series

Metal Series

5080CTC3-PWColour Touch Screen Controller, 6.4” Colour, Pure White Glass Fascia (less wall box, less power supply)

Pictured: Saturn Pure White

5050CTC3-GBColour Touch Screen Controller, 6.4” Colour, Neo Battleship Grey Fascia (less wall box, less power supply)

Pictured: Neo Battleship Grey/Brushed Aluminium

BS5000CTC3‘B’ Style Metal Fascia, Colour Touch Screen Controller, 6.4” Colour, Stainless Steel Fascia (less wall box, less power supply)

Pictured: Stainless Steel

AVAILABLE COLOURS

Saturn Pure White (5080CTC3-PW)

Saturn White (5080CTC3-GF)

Saturn Cream (5080CTC3-3)

Saturn Black (5080CTC3-6)

Saturn Mid-Brown (5080CTC3-7)

Neo Battleship Grey/Brushed

Aluminium (5050CTC3-GB)

Neo White (5050CTC3-WE)

Neo Black (5050CTC3-BK)

Neo White/Brushed Aluminium

(5050CTC3-28)

Stainless Steel (BS5000CTC3)

Horizon Black (HB5000CTC3)

Page 46: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue46

C-Bus Input UnitsTouch Screen Controllers

C-Touch Spectrum Colour Touch Screen Controllers

• Wall mount or desktop, touch-sensitive colour LCD touch screen controllers

• Displays ‘pages’ of graphical items, such as buttons, sliders and images, that can perform C-Bus-related functions when pressed

• 320 x 240 pixel 65k colour LCD

• Adjustable LED backlighting with ambient light compensation

• Powered from C-Bus

• Proximity sensing for wake-up and control functions

• Anti-fingerprint screen

• Available with or without C-Bus Logic Engine features

• Programmed via a standard USB port (easily accessible)

• USB port can be used as a PC interface to a C-Bus system

• Separate RS-232 port is included for third party device integration (C-Bus Logic Engine model only)

• Programmed using drag and drop programming software (PICED)

• Real-time clock included for automatic scheduling of events

• Allows control from infrared handheld remote control

• Wide range of fascia colours and styles available (Saturn, Neo, Metal and Plastic versions)

• Dimensions 195mm x 136mm x 41.7mm (Saturn model)

• Units draw 75mA and are powered from C-Bus (separate power supply not required)

• Wall box ordered separately

• Wall cut-out size: 173.5mm x 114.5mm

Page 47: Clipsal C-Bus

47

C-Bus Input UnitsTouch Screen Controllers

C-5080CT2 and C-5080CTL2Colour Touch Screen Controller, Saturn Glass Fascia, available with and without C-Bus Logic Engine

Pictured: Saturn White

C-xx5000CT2 and C-xx5000CTL2Colour Touch Screen Controller, Metal Fascia, available with and without C-Bus Logic Engine

Pictured: Stainless Steel

C-5000CTD2 and C-5000CTDL2Colour Touch Screen Controller, Desktop, available with and without C-Bus Logic Engine

Pictured: White

Saturn Series - Wall Mount Metal Series - Wall Mount

Desktop Series

C-5050CT2 and C-5050CTL2 Colour Touch Screen Controller, Neo Fascia, available with and without C-Bus Logic Engine

Pictured: Neo Battleship Grey/Brushed Aluminium

Neo Series - Wall Mount

C-SC5000CT2 and C-SC5000CTL2Colour Touch Screen Controller, Plastic Fascia, available with and without C-Bus Logic Engine

Pictured: White

Plastic Series - Wall Mount

AVAILABLE COLOURS

Saturn Series

Saturn White (GF)

Saturn Pure White (PW)

Saturn Cream (3)

Saturn Black (6)

Saturn Mid-Brown (7)

Neo Series

Neo White (WE)

Neo White/Brushed

Aluminium (28)

Neo Battleship Grey (GB)

Neo Black (BK)

Plastic Series

White (WE)

Cream (CM)

Black (BK)

Metal Series

Stainless Steel (BS)

Brass (BB)

Horizon Black (HB)

Desktop Series

White (WE)

Grey (GY)

Black (BK)

Page 48: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue48

C-Bus Input UnitsTouch Screen Controllers

B&W MKII Touch Screen Controllers

• Wall mount or desktop, touch-sensitive black and white LCD touch screen controllers

• Displays ‘pages’ of graphical items, such as buttons, sliders and images, that can perform C-Bus related functions when pressed

• LCD resolution of QVGA (320 pixels x 240 pixels)

• Adjustable LCD screen backlighting with ambient light compensation

• LCD uses white on black technology to enhance clarity

• Available with or without C-Bus Logic Engine features.

• Programmed via a standard USB port (easily accessible)

• USB port can be used as a PC interface to a C-Bus System

• Separate RS-232 port is included for third party device integration (C-Bus Logic Engine model only)

• Compatible with version 4 of Clipsal’s Windows based drag and drop programming software (PICED)

• Real-time clock included for automatic scheduling of events

• Allows control from infrared handheld remote control

• Wide range of fascia colours and styles available (Saturn, Neo, Metal and Plastic versions)

• Dimensions 195mm x 136mm x 41.7mm (Saturn model)

• Units draw 65mA and are powered from C-Bus (separate power supply not required)

• Wall box ordered separately

• Wall cut-out size: 173.5mm x 114.5mm

Page 49: Clipsal C-Bus

49

C-Bus Input UnitsTouch Screen Controllers

5080CT2 and 5080CTL2 B&W MKII Touch Screen Controller, Saturn Glass Fascia. available with and without C-Bus Logic Engine

Pictured: Saturn White

xx5000CT2 and xx5000CTL2 B&W MKII Touch Screen Controller, Metal Fascia, available with and without C-Bus Logic Engine

Pictured: Stainless Steel

5000CTD2 and 5000CTDL2B&W MKII Touch Screen Controller, Desktop, available with and without C-Bus Logic Engine

Pictured: Black

Saturn Series - Wall Mount Metal Series - Wall Mount

Desktop Series

5050CT2 and 5050CTL2 B&W MKII Touch Screen Controller, Neo Fascia, available with and without C-Bus Logic Engine

Pictured: Neo Battleship Grey/Brushed Aluminium

Neo Series - Wall Mount

SC5000CT2 and SC5000CTL2 B&W MKII Touch Screen Controller Plastic Fascia, available with and without C-Bus Logic Engine

Pictured: Black

Plastic Series - Wall Mount

AVAILABLE COLOURS

Saturn Series

Saturn White (GF)

Saturn Pure White (PW)

Saturn Cream (3)

Saturn Black (6)

Saturn Mid-Brown (7)

Neo Series

Neo White (WE)

Neo White/Brushed

Aluminium (28)

Neo Battleship Grey (GB)

Neo Black (BK)

Plastic Series

White (WE)

Cream (CM)

Black (BK)

Metal Series

Stainless Steel (BS)

Brass (BB)

Horizon Black (HB)

Desktop Series

White (WE)

Grey (GY)

Black (BK)

Page 50: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue50

C-Bus Input UnitsTouch Screen Controllers

C-Touch 6.4” Colour Touch Screen Controller Accessories

• Mounting hardware and accessories to suit 6.4” Colour Touch Screen Controllers

• Wall box external dimensions: 224mm x 167mm x 68mm

• Cut-out size for plasterboard bracket: 208mm x 162mm

5000CTCWBWall Box for 6.4” Colour Touch Screen Controller

5000CTCNANail Bracket for 6.4” Colour Touch Screen Controller

5100P24/2700AUPower Supply to suit C-Bus 6.4” Colour Touch Screen Controller, V3, 24V d.c., 2.7A

5000CTCRMGyproc™ Bracket for 6.4” Colour Touch Screen Controller

5035TX2Remote Control to suit C-Bus

Touch Screen Controller (Spare)

Page 51: Clipsal C-Bus

51

C-Bus Input UnitsTouch Screen Controllers

C-Touch Spectrum Colour and B&W MKII Touch Screen Controller Accessories

• Mounting hardware and accessories to suit C-Touch Spectrum Colour and B&W MKII Touch Screen Controllers

• Wall box external dimensions: 179.5mm x 122.5mm x 55mm

5035TX2Remote Control to suit C-Bus Touch Screen Controller (Spare)

5000CT2WBWall Box for C-Touch Spectrum Colour and B&W MKII Touch Screen Controllers

5000CT2RS232RS232 Lead for Integrating with Third Party Devices (Logic Engine Model Only), suits C-Touch Spectrum Colour and B&W MKII Touch Screen Controllers

Page 52: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue52 Clipsal C-Bus Product Overview Catalogue52

C-Bus Output UnitsDimmer Units

High Powered Dimmers - Architectural Series with Onboard RCDs

• Modular design with individual dimmer channel cards

• Soft start load turn-on protects lamp filaments

• Voltage compensation to minimise load brightness variation if the a.c. supply voltage drifts

• Filtering reduces supply voltage signalling effects

• Linear output load power following input control

• Universal dimming technology auto-detects load type

• Cards rated at full load current (no derating)

• C-Bus network burden and system clock generator

• After mains fail; dimmers return to previous or preset values

• Local C-Bus override switches on front panel

• Channel status indicators on front control panel

• Onboard MCB protection

• Mounting brackets included for ease of installation

• Generous load and mains supply terminals

• Emergency lighting output for each channel

• Manual dimmer bypass switch on all channels

• Fan-free operation, reduces maintenance requirements

• Suitable for single or 3-phase track lighting applications with optional 3-phase MCBs

• Support for 128 onboard lighting scenes

• Full integration with DMX512

• Selectable predefined dimming curves

• 3 prioritised auxiliary inputs

12-Channel 6-Channel 3-Channel

Catalogue No. Dimensions (mm) H x W x D Catalogue No. Dimensions (mm)

H x W x D Catalogue No. Dimensions (mm) H x W x D

L5112D10UAR6 713 x 455 x 164 L5106D20UAR6 713 x 455 x 164 L5103D20UAR1 451 x 455 x 164L5112D5UAR6 713 x 412 x 164 L5106D16UAR6 713 x 455 x 164 L5103D16UAR1 451 x 455 x 164

L5106D10UAR3 451 x 455 x 164 L5103D10UAR1 289 x 455 x 164L5106D5UAR3 451 x 412 x 164 L5103D5UAR1 289 x 412 x 164

• Standby generator input

• Cross fading scene functions

• Optional ballast control card - providing relay, DSI, DALI (broadcast) or 0–10V d.c. control

• Complies with Australian (AS/NZS CISPR 15:2002) and International Standards for Light Dimmers

• Meets the requirements of AS/NZS 3000:2007 RCD Protection of Lighting Circuits

• Dimmer models may be available without onboard RCDs, please contact your Clipsal C-Bus specialist for further information

Page 53: Clipsal C-Bus

5353

C-Bus Output UnitsDimmer Units

L5106D10UAR36-Channel C-Bus

Architectural Dimmer, Universal - 10A Per Channel (3 RCDs Onboard)

L5106D20UAR66-Channel C-Bus Architectural Dimmer, Universal - 20A Per Channel (6 RCDs Onboard)

L5112D10UAR612-Channel C-Bus Architectural Dimmer, Universal10A Per Channel (6 RCDs Onboard)

12-Channel RCD 6-Channel RCD

L5103D5UAR13-Channel C-Bus Architectural Dimmer, Universal - 5A Per Channel (1 RCD Onboard)

L5103D20UAR130-Channel C-Bus Architectural Dimmer, Universal - 20A Per Channel (1 RCD Onboard)

3-Channel RCD

L5103D16UAR13-Channel C-Bus Architectural Dimmer, Universal - 16A Per Channel (1 RCD Onboard)

L5106D16UAR66-Channel C-Bus Architectural Dimmer, Universal - 16A Per Channel (6 RCDs onboard)

L5112D5UAR612-Channel C-Bus

Architectural Dimmer, Universal - 5A Per Channel (6 RCDs Onboard)

L5103D10UAR13-Channel C-Bus Architectural Dimmer, Universal - 10A Per Channel (1 RCD Onboard)

L5106D5UAR36-Channel C-Bus Architectural Dimmer, Universal - 5A Per Channel (3 RCDs Onboard)

Page 54: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue54 Clipsal C-Bus Product Overview Catalogue54

C-Bus Output UnitsDimmer Units

High Powered Dimmers - Professional Series with Onboard RCDs

• Modular design with individual dimmer channel cards

• Leading edge dimming technology

• Soft start load turn-on protects lamp filaments

• Voltage compensation to minimise load brightness variation if the a.c. supply voltage drifts

• Filtering reduces supply voltage signalling effects

• Linear output load power following input control

• Cards rated at full load current (no derating)

• C-Bus network burden and system clock generator

• After mains fail, dimmers return to previous or preset values

• Local C-Bus override switches on front panel

• Channel status indicators on front control panel

• Onboard MCB protection

• Mounting brackets included for ease of installation

• Generous load and mains supply terminals

• Emergency lighting output for each channel

• Manual dimmer bypass switch on all channels

• Fan-free operation, reduces maintenance requirements

• Suitable for single or 3-phase track lighting applications with optional 3-phase MCBs

• Optional ballast control card - providing relay, DSI, DALI (broadcast) or 0-10V d.c. control

• Complies with Australian (AS/NZS CISPR 15:2002) and International Standards for light dimmers

• Meets the requirements of AS/NZS 3000:2007 RCD Protection of Lighting Circuits

• Dimmer models may be available without onboard RCDs, please contact your Clipsal C-Bus specialist for further information

12-Channel 6-Channel 3-Channel

Catalogue No. Dimensions (mm) H x W x D Catalogue No. Dimensions (mm)

H x W x D Catalogue No. Dimensions (mm) H x W x D

L5112D20LPR12 713 x 455 x 164 L5106D20LPR6 451 x 455 x 164 L5103D20LPR1 289 x 455 x 164L5112D16LPR12 713 x 455 x 164 L5106D10LPR6 451 x 412 x 164 L5103D10LPR1 289 x 412 x 164L5112D10LPR12 713 x 412 x 164 L5106D5LPR6 451 x 405 x 115 L5103D5LPR1 289 x 405 x 115L5112D5LPR12 713 x 405 x 115 L5106D10LPR3 451 x 412 x 164L5112D10LPR6 713 x 412 x 164 L5106D5LPR3 451 x 405 x 115L5112D5LPR6 713 x 405 x 115

Page 55: Clipsal C-Bus

5555

C-Bus Output UnitsDimmer Units

L5106D10LPR36-Channel C-Bus

Professional Dimmer, LE - 10A Per Channel (3 RCDs Onboard)

L5106D5LPR36-Channel C-Bus Professional Dimmer, LE - 5A Per Channel (3 RCDs Onboard)

L5106D20LPR66-Channel C-Bus

Professional Dimmer, LE - 20A Per Channel (6 RCDs Onboard)

L5112D20LPR1212-Channel C-Bus Professional Dimmer, LE - 20A Per Channel (12 RCDs Onboard)

L5112D16LPR1212 Channel C-Bus

Professional Dimmer, LE - 16A Per Channel (12 RCDs Onboard)

12-Channel RCD 6-Channel RCD

L5103D20LPR13-Channel C-Bus Professional Dimmer, LE - 20A Per Channel (1 RCD Onboard)

3-Channel RCD

L5103D10LPR13-Channel C-Bus Professional Dimmer, LE - 10A Per Channel (1 RCD Onboard)

L5106D10LPR66-Channel C-Bus

Professional Dimmer, LE - 10A Per Channel (6 RCDs Onboard)

L5106D5LPR66-Channel C-Bus Professional Dimmer, LE - 5A Per Channel (6 RCDs Onboard)

L5112D10LPR1212-Channel C-Bus Professional Dimmer, LE - 10A Per Channel (12 RCDs Onboard)

L5112D5LPR1212-Channel C-Bus

Professional Dimmer, LE - 5A Per Channel (12 RCDs Onboard)

L5103D5LPR13-Channel C-Bus Professional Dimmer, LE - 5A Per Channel (1 RCD Onboard)

L5112D10LPR612-Channel C-Bus

Professional Dimmer, LE - 10A Per Channel (6 RCDs Onboard)

L5112D5LPR612-Channel C-Bus Professional Dimmer, LE - 5A Per Channel (6 RCDs Onboard)

Page 56: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue56 Clipsal C-Bus Product Overview Catalogue56

C-Bus Output UnitsDimmer Units

High Powered Dimmers - Architectural and Professional Series - Chassis Only

• A selection of C-Bus Architectural Dimmers are available without channel cards including:

6-channel 20A per channel (non-RCD)

12-channel 10A per channel (non-RCD)

6-channel 10A per channel (non-RCD)

6-channel 20A per channel, supplied with 6 RCDs

12-channel 10A per channel, supplied with 12 RCDs

6-channel 10A per channel, supplied with 6 RCDs

• A selection of C-Bus Professional Dimmers are available without channel cards including:

12-channel 20A per channel (non-RCD)

6-channel 20A per channel (non-RCD)

12-channel 10A per channel (non-RCD)

6-channel 10A per channel (non-RCD)

12-channel 20A per channel, supplied with 12 RCDs

6-channel 20A per channel, supplied with 6 RCDs

12-channel 10A per channel, supplied with 12 RCDs

6-channel 10A per channel, supplied with 6 RCDs

High Powered Dimmers - Architectural and Professional Series - Channel Cards

• A range of dimmer channel cards are available including:

Ballast control / relay output (DSI / DALI / 0 – 10V d.c. or relay output)

20A universal dimming

16A universal dimming

10A universal dimming

5A universal dimming

20A leading edge dimming

16A leading edge dimming

10A leading edge dimming

10A trailing edge dimming

5A leading edge dimming

3A leading edge dimming

L5106D20UAR6C6 Channel C-Bus Architectural Dimmer, Chassis Only, 20A per channel, 6 RCDs onboard

L5112D20LPR12C12 Channel C-Bus Professional Dimmer, Chassis Only, 20A per channel, 12 RCDs onboard

Page 57: Clipsal C-Bus

5757

C-Bus Output UnitsDimmer Units

Dimmer Channel Cards Accessories

5150DMXDMX Connector Kit to suit C-Bus Architectural Dimmers. 3-Way Phoenix Connector to 2-Panel Mount XLR Female Connectors

L51CM-SBBallast Control Card for Relay, DSI, DALI (broadcast) or 0–10V d.c. Control

L51CM-SU1010A Universal Dimming Channel Card

L51CM-SLE2020A Leading Edge Dimming Channel Card

L51CM-SLE1010A Leading Edge Dimming Channel Card

Page 58: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue58 Clipsal C-Bus Product Overview Catalogue58

C-Bus Output UnitsDimmer Units

L5504D2U4-Channel C-Bus Universal Dimmer 250V a.c, 2.5A Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 4-Channel Universal Dimmer

• 4-channel universal dimmer, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Features 4 channels of 2.5A rating

• Suitable for use with leading edge or trailing edge compatible low voltage transformers

• Suitable for low voltage electronic transformers, incandescent lamps and low voltage lamps with iron core transformers

• Features automatic load sensing

• Features a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to a C-Bus network

• Features an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

DIN Rail-Mounted 4-Channel Universal Dimmer - without C-Bus Power Supply

• 4-channel universal dimmer, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Features 4 channels of 2.5A rating

• Suitable for use with leading edge or trailing edge compatible low voltage transformers

• Suitable for low voltage electronic transformers, incandescent lamps and low voltage lamps with iron core transformers

• Features automatic load sensing

• Features a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to a C-Bus network

• Does not source current to the network

• Draws 18mA from C-Bus when mains is not connected

• C-Bus Learn Enabled

L5504D2UP4-Channel C-Bus Universal Dimmer 250V a.c, 2.5A Per Channel, No Inbuilt C-Bus Power Supply

Page 59: Clipsal C-Bus

5959

C-Bus Output UnitsDimmer Units

L5508D1A8-Channel Dimmer 250V a.c, 1A Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 8-Channel LE Dimmer

• 8-channel dimmer, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Leading edge dimming technology

• Features 8 channels of 1A output, suitable for incandescent and low voltage lighting

• Features a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Features an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

L5508D1AP8-Channel Dimmer 250V a.c, 1A Per Channel, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 8-Channel LE Dimmer - without C-Bus Power Supply

• 8-channel dimmer, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Leading edge dimming technology

• Features 8 channels of 1A output, suitable for incandescent and low voltage lighting

• Features a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Does not source current to the network

• Draws 18mA from the C-Bus when mains is not connected

• C-Bus Learn Enabled

Page 60: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue60

C-Bus Output UnitsDimmer Units

Dimmer CFL and Mains LED Bypass Module

• Adapts dimming behaviour of phase cut dimmer output

• Used for direct control of various extra low power electronic load types (such as CFLs and mains powered LEDs)

• Improved dimming performance

• Inbuilt relay eliminates off state current from phase cut dimmer output

• Available in 2M wide DIN rail or inline enclosure

5501OSRBDCFL and Mains LED Bypass Module, DIN Rail Mount

5001OSRBDCFL and Mains LED Bypass Module, Inline

Page 61: Clipsal C-Bus

61

C-Bus Output UnitsDimmer Units

LED Load Driver Module

• Adapts dimming behaviour of phase cut dimmer output

• Used for direct control of various extra low voltage LED loads

• 1-channel LED driver

• Constant current 36V, 700mA

• Available in 2M wide DIN rail or inline enclosure

5501LDConstant Current LED driver, 1 Channel, 36V 700mA, DIN Rail Mount

5001LDConstant Current LED Driver, 1 Channel, 36V 700mA, Inline

Page 62: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue62 Clipsal C-Bus Product Overview Catalogue62

C-Bus Output UnitsDimmer Units

L5504D2A4-Channel Dimmer 250V a.c, 2A Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 4-Channel LE Dimmer

• 4-channel dimmer, DIN rail- mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Leading edge dimming technology

• Features 4-channels of 2A output, suitable for incandescent and low voltage lighting

• Features a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Features a 200mA C-Bus power supply

• C-Bus Learn Enabled

L5504D2AP4-Channel Dimmer 250V a.c, 2A Per Channel, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 4-Channel LE Dimmer - without C-Bus Power Supply

• 4-channel dimmer, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Leading edge dimming technology

• Features 4 channels of 2A output, suitable for incandescent and low voltage lighting

• Features a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Does not source current to the network

• Draws 18mA from the C-Bus when mains is not connected

• C-Bus Learn Enabled

Page 63: Clipsal C-Bus

6363

C-Bus Output UnitsDimmer Units

L5508DSI8-Channel Dimmer for DSI Electronic Ballasts 250V a.c, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 8-Channel DSI Gateway

• 8-channel dimmer for DSI ballasts, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Provides C-Bus control of electronic DSI digital ballasts

• The module controls up to 100 DSI ballasts per channel

• Up to 10 units may be connected to any C-Bus network

• Used in conjunction with electronic DSI ballasts

• The dimmer features a 200mA C-Bus power supply

• C-Bus Learn Enabled

L5508DSIP8-Channel Dimmer for DSI Electronic Ballasts 250V a.c, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 8-Channel DSI Gateway - without C-Bus Power Supply

• 8-channel dimmer for DSI ballasts, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Provides C-Bus control of electronic DSI digital ballasts

• The module controls up to 100 DSI ballasts per channel

• Up to 100 units may be connected to any C-Bus network

• Used in conjunction with electronic DSI ballasts

• Draws 18mA from the C-Bus network when mains is not connected

• C-Bus Learn Enabled

Page 64: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue64 Clipsal C-Bus Product Overview Catalogue64

C-Bus Output UnitsRelay Units

L5512RVF12-Channel Relay 250V a.c, 10A Load Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 12-Channel 10A Relay

• 12-channel relay module, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Featuring 12 channels of voltage-free relay switching

• Rated at 10A incandescent or 10A fluorescent load per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Incorporates an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

L5512RVFP12-Channel Relay 250V a.c, 10A Load Per Channel, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 12-Channel 10A Relay - without C-Bus Power Supply

• 12-channel relay module, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Featuring 12 channels of voltage-free relay switching

• Rated at 10A incandescent or 10A fluorescent load per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Draws 18mA from C-Bus network when mains is not connected

• C-Bus Learn Enabled

Page 65: Clipsal C-Bus

6565

C-Bus Output UnitsRelay Units

L5508RVF8-Channel Relay 250V a.c, 10A Load Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 8-Channel 10A Relay

• 8-channel relay module, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Featuring 8 channels of voltage-free relay switching

• Rated at 10A incandescent or 10A fluorescent load per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Incorporates an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

L5508RVFP8-Channel Relay 250V a.c, 10A Load Per Channel, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 8-Channel 10A Relay - without C-Bus Power Supply

• 8-channel relay module, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• Featuring 8 channels of voltage-free relay switching

• Rated at 10A incandescent or 10A fluorescent load per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Draws 18mA from C-Bus network when mains is not connected

• C-Bus Learn Enabled

Page 66: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue66 Clipsal C-Bus Product Overview Catalogue66

C-Bus Output UnitsRelay Units

L5504RVF4 Channel Relay, 250V a.c, 10A Load Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 4-Channel 10A Relay

• 4-channel relay module, DIN rail-mounted

• 8M DIN modules wide

• Dimensions 144mm x 85mm x 65mm

• Featuring 4 channels of voltage-free relay switching

• Rated at 10A incandescent or 10A fluorescent load per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Incorporates an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

L5504RVFP4 Channel Relay 250V a.c, 10A Load Per Channel, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 4-Channel 10A Relay - without C-Bus Power Supply

• 4-channel relay module, DIN rail-mounted

• 8M DIN modules wide

• Dimensions 144mm x 85mm x 65mm

• Featuring 4 channels of voltage-free relay switching

• Rated at 10A incandescent or 10A fluorescent load per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Draws 18mA from C-Bus network when mains is not connected

• C-Bus Learn Enabled

Page 67: Clipsal C-Bus

6767

C-Bus Output UnitsRelay Units

L5504RVF204 Channel Relay, 250V a.c, 20A Load Per Channel, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 4-Channel 20A Relay

• 4-channel 20A relay module, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• 4 channels of voltage-free relay switching

• Rated at 20A incandescent, 20A HID or 20A fluorescent load per channel

• Relays feature magnetic latching

• Built-in mechanical level for manual changeover of relay state

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Incorporates an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

L5504RVF20P4-Channel Relay, 250V a.c, 20A Load Per Channel, No Inbuilt C-Bus Power Supply

DIN Rail-Mounted 4-Channel 20A Relay - without C-Bus Power Supply

• 4-channel 20A relay module, DIN rail-mounted

• 12M DIN modules wide

• Dimensions 215mm x 85mm x 65mm

• 4 channels of voltage-free relay switching

• Rated at 20A incandescent, 20A HID or 20A fluorescent load per channel

• Relays feature magnetic latching

• Built-in mechanical level for manual changeover of relay state

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Draws 18mA from the C-Bus when mains is not connected

• C-Bus Learn Enabled

Page 68: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue68 Clipsal C-Bus Product Overview Catalogue68

C-Bus Output UnitsRelay Units

L5504RVFCP4 Channel Changeover Relay, 250V a.c, No Inbuilt C-Bus

Power Supply

DIN Rail-Mounted 4-Channel Changeover Relay

• 4-channel changeover relay with interlock features, DIN rail-mounted

• 8M DIN modules wide

• Dimensions 144mm x 85mm x 65mm

• Used for control of air conditioning systems (ON/OFF, low, medium and high) and shutter or blind control (UP/DOWN)

• The unit can be simply wired to achieve electrical interlocking, for use where outputs are all mutually exclusive

• Rated at 10A resistive, 5A incandescent/inductive, 1A fluorescent per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 10 units may be connected to any C-Bus network

• Incorporates an inbuilt 200mA C-Bus power supply

• C-Bus Learn Enabled

L5504RVFC4-Channel Changeover Relay, 250V a.c, Learn Enabled, Inbuilt 200mA C-Bus Power Supply

DIN Rail-Mounted 4-Channel Changeover - without C-Bus Power Supply

• 4-channel changeover relay with interlock features, DIN rail-mounted

• 8M DIN modules wide

• Dimensions 144mm x 85mm x 65mm

• Used for control of air conditioning systems (ON/OFF, low, medium and high) and shutter or blind control (UP/DOWN)

• The unit can be simply wired to achieve electrical interlocking, for use where outputs are all mutually exclusive

• Rated at 10A resistive, 5A incandescent/inductive, 1A fluorescent per channel

• Incorporates a software selectable network burden and C-Bus system clock

• A maximum of 100 units may be connected to any C-Bus network

• Draws 18mA from C-Bus when mains is not connected

• C-Bus Learn Enabled

Page 69: Clipsal C-Bus

6969

C-Bus Output UnitsRelay Units

DIN Rail-Mounted Single-Channel Fan Control Relay

• Single channel relay for the direct control of ceiling sweep fans

• Capacitor control (utilise capacitor supplied with fan)

• Inbuilt capacitor bay

• High temperature rated (to 70°C)

• DIN rail-mounted, 3M wide

• Dimensions 53 x 93mm x 65mm

• Up to 3-speed control of fan

• Programmable labels for fan speed broadcasted onto C-Bus

• Powered from C-Bus, draws 18mA

• Optional remote mounting enclosure available, catalogue number 5501FRE

L5501RBCPC-Bus Shutter Relay, 250V a.c, No Inbuilt C-Bus Power Supply

5501RERemote Mounting Enclosure, Suits C-Bus Shutter Relay

DIN Rail-Mounted Single-Channel Shutter Relay

• Single channel relay for the direct control of motorised blinds, curtains or shutters via C-Bus

• DIN rail-mounted, 2M wide

• Dimensions 36 x 93mm x 63mm

• Allows UP/DOWN and stop control

• A maximum of 80 units may be connected to a C-Bus network

• Powered from C-Bus, draws 18mA

• C-Bus Learn Enabled

• Optional remote mounting enclosure available (catalogue number 5501RE)

L5501RFCPC-Bus Fan Control Relay, 250V a.c, No Inbuilt C-Bus Power Supply

5501FRERemote Mounting Enclosure, Suits C-Bus Fan Control Relay

Page 70: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue70 Clipsal C-Bus Product Overview Catalogue70

C-Bus Output UnitsRelay Units

5101R1-Channel Relay 250V a.c. 10A Inductive Load

Inline Single-Channel Relay

• Features 1-channel of 250V a.c. switching

• Dimensions 198mm x 42mm x 39mm

• Suitable for incandescent, inductive and fluorescent switching up to a maximum load of 10A

• A maximum of 100 units may be connected to any C-Bus network

• Does not draw any current from C-Bus network when mains power is connected

Inline Single-Channel Relay - with Cord Set

• Features 1-channel of 250V a.c. switching

• Dimensions 198mm x 42mm x 39mm

• Prewired with terminated C-Bus cable and terminated double insulated mains cable

• Suitable for incandescent, inductive and fluorescent switching up to a maximum load of 10A

• A maximum of 100 units may be connected to any C-Bus network

• Does not draw any current from C-Bus network when mains power is connected

5101RC1-Channel Relay 250V a.c. 10A Inductive Load, with Cord Set

Page 71: Clipsal C-Bus

7171

C-Bus Output UnitsRelay Units

5102RVF2-Channel Relay 250V a.c, 10A Inductive Per Channel

Inline 2-Channel Relay

• Features 2 channels of 250V a.c. switching (voltage free)

• Dimensions 198mm x 42mm x 39mm

• Suitable for incandescent, inductive and fluorescent switching up to a maximum load of 10A per channel

• A maximum of 100 units may be connected to any C-Bus network

• Does not draw any current from C-Bus network when mains power is connected

Extra Low Voltage 8-Channel Relay

• 8 x single-pole, double-throw (changeover) relays

• Powered from C-Bus, draws 32mA

• Contacts rated 2A (AC3) @ 30V a.c./d.c.

• Relays can be operated in pairs

• Local override buttons

• High temperature rated (to 50°C)

• IP5x rated enclosure (dustproof)

• Removable terminals

L5108RELVP8-Channel Extra Low Voltage Relay 30V a.c./d.c. 2A Per Channel

Page 72: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue72 Clipsal C-Bus Product Overview Catalogue72

Infrared Transmitter Output Units

• Transmit IR codes to third party devices

• Capable of broadcasting IR messages through 2 IR output channels (via 3.5mm mini audio mono sockets)

• Single or dual-head emitter leads (ordered separately) are connected to the output jacks (catalogue numbers 8050LD and 8050/2LD)

• Programmed via the high-speed programming cable (catalogue number 5100HSCU, ordered separately)

• The installer has the facility to modify the stored codes using Windows-based application software

• Store a library of commonly used IR codes

• The infrared controller is based on the standard range of C-Bus 4-button wall switches

• Available in White Electric

• Draws 32mA from the C-Bus network

C-Bus Output UnitsInfrared Output Units

Page 73: Clipsal C-Bus

7373

C-Bus Output UnitsInfrared Output Units

5100RPInfrared Code Learning Unit. Required for learning third party infrared codes. Not included in the software code library.

5034NIRT2-Channel Infrared Transmitter Unit, 2000 Series Wall Plate

Pictured: White

SC5034NIRT2-Channel Infrared Transmitter Unit, Slimline SC2000 Series Wall Plate

Pictured: White

SL5034NIRT2-Channel Infrared Transmitter Unit, Eclipse SL2000 Series Wall Plate

Pictured: White

C5034NIRT2-Channel Infrared Transmitter Unit, Classic C2000 Series Wall Plate

Pictured: White

5100HSCUHigh-Speed Programming Cable for C-Bus 2-Channel Infrared Transmitter Unit.

Accessories

8050LDIR Emitter Lead, Single

8050/2LDIR Emitter Lead, Dual

Classic C2000 Series

2000 Series

Eclipse SL2000 Series

Slimline SC2000 Series

Page 74: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue74 Clipsal C-Bus Product Overview Catalogue74

C-Bus System Unitsand Accessories

C-Bus Wiser Home Controller MkII

• Purpose designed C-Bus system controller

• Resides as node on the Home network

• Single Ethernet (LAN) connection

• Wi-Fi client only (not a Wireless Access Point)

• Onboard C-Bus connection o Dual C-Bus (internal) connections on one single physical C-Bus connection o Can be used with external CNI if no physical C-Bus connection is available

• User interface on PC (via Web Browser)

• HDMI connection for user interface on a display monitor o Support for CEC codes through HDMI

• USB sockets and SD card slot o USB keyboard and mouse o Digital audio files for C-Bus Ripple o Storage of surveillance images

• Onboard memory for storage of images, logs etc.

• Scene and scheduling capabilities onboard

• Full Logic Engine capabilities onboard

• Control devices such as lighting, multi-room audio, HVAC, blinds and irrigation

• Allows remote access to re-program Wiser and C-Bus from outside the home/building

• Future integration with many IP based devices

• C-Bus Multi-Room Audio (MRA) support with onboard Ripple server and client

• Support for DHCP (client)

• Supports fixed IP address

• Support for DYNDNS services

• Support for NTP with client definable server locations

• Power Over Ethernet (POE) support

• SAMBA support

• Support for User and Location profiles

• Support for 20 channels of power monitoring and logging

• Comprehensive Wiser diagnostics functionality

• Multiple installation options; on a desktop or with AV equipment, on shelving or in an equipment rack and also wall mounting (using keyhole points)

• User interface on portable devices such as mobile phones and web tablets (via dedicated Android and iOS Apps) providing complementary control of native C-Bus on-wall devices

5200WHC2C-Bus Wiser Home Controller MkII

Page 75: Clipsal C-Bus

7575

C-Bus System Unitsand Accessories

Laptop

Mobile Phone

Internet

12.01 242 1

Multi-RoomAudio

SecuritySystem

Blinds and Curtains Air Conditioning Lighting

C-BusWall Switch

C-BusTouch Screen

Controller

C-BusThermostat

Wi-Fi

C-Bus Home Control Network

Home NetworkHDMI

IP Camerawith Wi-Fi

Laptopwith Wi-Fi

Mobile Phonewith Wi-Fi

Wiser Home Controller MkII

Tabletwith Wi-Fi

Wiser Home Control MkII System Architecture

Internet Modem Router

PC (Windows, Apple or Linux)

IP CameraTV (HDMI)

Page 76: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue76 Clipsal C-Bus Product Overview Catalogue76

C-Bus System Unitsand Accessories

Pascal Automation Controller

• Provides extended conditional and real-time event programming for C-Bus

• Programming downloaded directly to the unit

• Connects directly to C-Bus (can act as a PC interface)

• Powered from C-Bus

• 4M DIN modules wide

• 2 x RS-232 ports for third party device control

• A scheduling tool allows time-based events to be programmed into the unit

• A scene programming tool allows installers to quickly and easily program scenes into the unit

• A programming wizard provides a GUI based method for creating basic logic programs

• More complex programs are produced by advanced users utilising the free-form text programming method

• Programming language based on the standard Pascal computer language, enhanced by Clipsal with specific commands related to C-Bus control

• The language supports commands such as:

conditional logic (if, then, and, or, not, etc.)

flow control (for, repeat, while)

variables (integer, real, Boolean, character, string)

control and monitor C-Bus group addresses

control and monitor C-Bus scenes

C-Bus tag names

serial (RS-232) input/output.

5500PACAC-Bus Pascal Automation Controller

Page 77: Clipsal C-Bus

7777

C-Bus System Unitsand Accessories

Current Measurement Unit and Current Transformer (CT)

• Measures and reports a circuit’s instantaneous electrical power consumption over C-Bus

• Current monitoring is performed via a split core current transformer (CT)

• 4-channel unit (measure up to 4 electrical circuits per unit)

• Display energy use on C-Bus 6.4” Colour Touch Screen, Schedule Plus, HomeGate software and Wiser Home Control

• Raises C-Bus alerts and warning messages based on predefined thresholds

• Control electrical devices based on predefined thresholds (load shed)

• Can provide confirmation that electrical devices are operating as expected

• DIN rail mounted, 4M wide

• C-Bus supply voltage: 15–36V d.c. @ 18mA (does not provide power to the C-Bus network)

• CT is split core type and measures current between 0–80A (supplied separately)

5504CMUC-Bus Current Measurement Unit, 4-Channel

5100CT800A-80A 2-Wire Split Core CT

C-Bus BACnet Gateway

• C-Bus to BACnet Gateway hardware interface

• Allows exchange of information between C-Bus and a building management system (BMS) based on the BACnet protocol

• One full C-Bus lighting application is supported

• BACnet values supported: analogue read, analogue write and binary read

• Supplied preconfigured

• Supplied with an enclosure, C-Bus PC Interface and BACnet gateway power supply

5000BACNETC-Bus BACnet Gateway

Page 78: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue78 Clipsal C-Bus Product Overview Catalogue78

C-Bus System Unitsand Accessories

C-Bus DMX Gateway

• C-Bus to DMX-512-A Gateway

• Map 12 C-Bus group addresses and levels to multiple combinations of DMX slot addresses

• Master device for transmission only (must be in position 1 on DMX network)

• Powered from C-Bus, draws 50mA

• DIN rail mounted, 4M wide

• Supplied with 300mm DMX cable

5500DMXC-Bus DMX Gateway

Signal name Wire Colour XLR-5 Connector

Ground (GND) Shield pin 1

Control Data Minus 1- White/Blue Stripe pin 2

Control Data Plus 1+ Blue/White Stripe pin 3

Not Used pin 4

Not Used pin 5

C-Bus to DMX Gateway

C-Bus Cable Assembly DMX Desk Control Unit

to DMX Load

C-Bus Network

300 mm

DMX Cable Assembly

Panel or Enclosure

Page 79: Clipsal C-Bus

7979

C-Bus System Unitsand Accessories

0–10V Analogue Output Unit

• Analogue output module, DIN rail mounted

• 4M DIN modules wide

• Requires a 240V a.c. connection

• Dimensions 72mm x 85mm x 65mm

• Can either source or sink current and is used to drive most types of 0–10V electronic dimmable ballats

• The unit provides 4 independent output channels

• Powered from C-Bus and requires 18mA at 15–36V d.c. for correct operation

• Draws 18mA from the C-Bus when mains is not connected

• C-Bus Learn Enabled

L5504AMP4-Channel Analogue Output, 0–10V

Earth

Neutral

a.c. Mains Supply Active (Line/Hot)

Unit

C-Bus

1 2 3 4

Local Toggle Buttons

0-10V ANALOGUE OUTPUT

C-Bus Connections

C-Bus Network C-Bus Network

Load Load Load Load

4B4A3B3A

2B2A1B1A

Earth

Neutral

a.c. Mains Supply Active (Line/Hot)

Unit

C-Bus

1 2 3 4

0-10V ANALOGUE OUTPUT

C-Bus Connections

1A 1B 2B 3B 4B

Loads Loads

All ‘A’ terminals are internally connected to common ground.

Page 80: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue80 Clipsal C-Bus Product Overview Catalogue80

C-Bus DALI Gateway

• C-Bus to DALI Gateway, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Supports DALI lamp and ballast failure information over to the C-Bus network

• Capable of controlling up to 2 DALI networks

• Supports DALI group addresses, short addresses and scenes the DALI global (broadcast) address

• A remote switch input is included to turn all DALI output channels to the ON or OFF states, irrespective of the current state of C-Bus, including no C-Bus

• Incorporates C-Bus clock and network burden

• Up to 50 DALI Gateways can be connected to a single C-Bus network

• Draws 32mA from a C-Bus network

5502DALC-Bus DALI Gateway

Mains Supply

DALI Power Supply

Mains Supply

DALI Power Supply

DALI 2 Network

DALI 1 Network

Mai

nsB

alla

st

Lam

p

Bal

last

Lam

p

Mai

ns

C-Bus RJ45 Connections

C-Bus Network

DALI DALI1 2

C-Bus

DALI Gateway

Unit- Comms

C-Bus

C-Bus System Unitsand Accessories

Page 81: Clipsal C-Bus

818181

5502DAL2PSC-Bus DALI Gateway Plus Two DALI Power Supplies

C-Bus DALI Gateway - with DALI Power Supplies

• C-Bus to DALI Gateway, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Supports DALI lamp and ballast failure information over to the C-Bus network

• Capable of controlling up to 2 DALI networks

• Supports DALI group addresses, short addresses and scenes the DALI global (broadcast) address

• A remote switch input is included to turn all DALI output channels to the ON or OFF states, irrespective of the current state of C-Bus, including no C-Bus

• Incorporates C-Bus clock and network burden

• Up to 50 DALI Gateways can be connected to a single C-Bus network

• Draws 32mA from a C-Bus network

• Supplied with two 1M DIN DALI power supply modules

Mains Supply

DALI Power Supply

Mains Supply

DALI Power Supply

DALI 2 Network

DALI 1 Network

Mai

nsB

alla

st

Lam

p

Bal

last

Lam

p

Mai

ns

C-Bus RJ45 Connections

C-Bus Network

DALI DALI1 2

C-Bus

DALI Gateway

Unit- Comms

C-Bus

C-Bus System Unitsand Accessories

Page 82: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue82 Clipsal C-Bus Product Overview Catalogue82

C-Bus System Unitsand Accessories

C-Bus PC Interface

• C-Bus PC interface, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Features 2 connections to C-Bus (2 x RJ45 sockets)

• Features 3 connections to RS232 (2 x RJ45 and1 x DB9 sockets)

• Draws 32mA from a C-Bus network

5500PCC-Bus PC Interface

5500PCUC-Bus USB PC Interface

5500PSC-Bus Power Supply, 350mA

C-Bus PC Interface - USB

• C-Bus PC interface, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Features 2 connections to C-Bus (2 x RJ45 sockets)

• Features 1 connection to USB (1 x type B socket)

• Draws 32mA from a C-Bus network

C-Bus Power Supply

• C-Bus power supply, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Supplies 350mA at 18–36V d.c. to the C-Bus network

• Each power supply supports approximately 18 standard C-Bus units

• Up to 5 power supplies may be used on any single C-Bus network

Page 83: Clipsal C-Bus

8383

C-Bus System Unitsand Accessories

C-Bus Ethernet Network Interface

• C-Bus Ethernet network interface, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Provides a 2-way C-Bus to Ethernet network interface

• Allows C-Bus commands to be distributed via a 100Base-TX or 10Base-T Ethernet (TCP/IP) network

• Features 2 x C-Bus RJ45 connections and 1 x Ethernet RJ45 connection

• The unit requires an external 6–12V d.c. power supply unit (supplied)

5100CN2C-Bus Inline Ethernet Network Interface

C-Bus Inline Ethernet Network Interface

• C-Bus Ethernet network interface, inline

• Provides a 2-way C-Bus to Ethernet network interface

• Allows C-Bus commands to be distributed via a 100Base-TX or 10Base-T Ethernet (TCP/IP) network

• Features 1 x C-Bus terminal block and 1 x Ethernet RJ45 connection

• The unit requires an external 5–24V d.c. power supply unit (supplied with 24V d.c. power supply unit)

• 24V d.c., 1.25A power supply unit

• Suits C-Bus Wiser Home Controller MkII and C-Bus Inline Network Interface

C-Bus Network Bridge

• C-Bus network bridge, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Provides a 2-way C-Bus to C-Bus network interface

• Draws 18mA from a C-Bus network

5500NBC-Bus Network Bridge

5500CN2C-Bus Ethernet Network Interface

5100P24/1250Power Supply 24V d.c. 1.25A

Power Supply 24V d.c., 1.25A

• 24V d.c., 1.25A power supply unit

• Suits C-Bus Wiser Home Controller MkII and C-Bus Inline Network Interface

Page 84: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue84 Clipsal C-Bus Product Overview Catalogue84

C-Bus System Unitsand Accessories

C-Bus Network Analyser

The Network Analyser is a tool used to measure various C-Bus system parameters:

power available clock signal present excess voltage add/remove burden excess cable indication.

• Dimensions 60.5mm x 120mm x 30.3mm

• Measures capacitance, burden, clock signal and network voltage

• The network analyser is powered from C-Bus and supplied with leads

C-Bus Network Monitor

• C-Bus network monitor, DIN rail mounted

• 4M DIN modules wide

• Dimensions 72mm x 85mm x 65mm

• Activates C-Bus remote ON override in the event of a C-Bus network failure

• Passive device, does not transmit any data onto the network

• Draws 18mA from a C-Bus network

Cat. 5e Shutter Socket

• Pink modular Cat. 5e RJ45 Shuttered Socket

• Suits C-Bus installations

• Easily identify C-Bus sockets

30RJ45SMA5SH,PKPink Modular Cat. 5e RJ45 Shuttered Socket

5500NMAC-Bus Network Monitor

5100NAC-Bus Network Analyser

Page 85: Clipsal C-Bus

8585

C-Bus System Unitsand Accessories

C-Bus Cable

• 4-pair, Category 5, unshielded cable with a unique outer colour sheath specifically designed for the C-Bus system

• A maximum of 1000 metres of cable is permitted on any one C-Bus network

• 2 pairs are used for the C-Bus connection; C-Bus positive (blue + orange) and C-Bus negative (blue/white + orange/white)

• The C-Bus cable must be segregated from the mains cable in C-Bus installations

• C-Bus cable has a mains-rated low smoke zero halogen (LSZH) outer sheath

• Suitable for use inside electrical enclosures

• Available in both solid and stranded conductors

C-Bus Network Burden

• C-Bus network RJ45 hardware burden

• Supplied in pack of 105500BURC-Bus Network Burden

5005C305BC-Bus Cat. 5, 4-Pair, UTP Cable, 305 Metres, Solid Conductors

5005C305BSTC-Bus Cat. 5, 4-Pair, UTP Cable, 305 Metres, Stranded Conductors

Page 86: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue86 Clipsal C-Bus Product Overview Catalogue86

C-Bus Software

C-Bus Toolkit Software

C-Bus Toolkit software is a PC-accessible C-Bus network configuration and customer solution programming utility. It allows the installer to:

• connect directly to an installer C-Bus network via a C-Bus PC interface unit to synchronise logical and physical C-Bus customer site data

• configure the C-Bus network to define the C-Bus architecture of the customer site and ensure C-Bus units can communicate with each other

• program and commission the customer solution

• save, backup and restore sites. C-Bus Toolkit has a database for creating and storing customer site programming as projects.

C-Bus Software Installer Dongle

The C-Bus Software Installer Dongle is a valuable installer tool for creating/commissioning projects using C-Bus Schedule Plus, HomeGate software and C-Bus OPC Server software. The dongle is time restricted and allows the software to operate in ‘normal’ mode for anywhere between 48 to 72 hours per use (the software then returns to Evaluation/Demo mode). The installer dongle is compatible with future software releases.

5000SDINST/1Installer Dongle for C-Bus Software, Unlimited Networks

Page 87: Clipsal C-Bus

8787

C-Bus Software

HomeGate Software

The HomeGate application software provides a powerful, but simple to use interface to C-Bus via a standard PC. HomeGate provides scheduling, manual control and monitoring of a domestic C-Bus system from a PC running Windows 98, 2000, NT, ME or XP. HomeGate comprises project editor, real-time monitoring and control, a real time scheduler, security and access control and Internet access. It also includes help and support documentation.

A HomeGate USB dongle must be purchased to unlock the software from an evaluation version to a full working version.

5000SDHG2/42 Network Licence Dongle for HomeGate

5000SDHG10/410 Network Licence Dongle for HomeGate

Page 88: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue88 Clipsal C-Bus Product Overview Catalogue88

C-Bus Software

Schedule Plus Software

Schedule Plus application software provides a powerful and easy use interface to C-Bus via a standard PC. Schedule Plus has been developed specifically for commercial and industrial applications. It provides scheduling, manual control and monitoring of a C-Bus system from a PC running Windows 98, 2000, NT, ME or XP. A Schedule Plus USB dongle must be purchased to unlock the software from an evaluation version to a full working version.

5000SDSP2/42 Network Licence Dongle for Schedule Plus

5000SDSP10/410 Network Licence Dongle for Schedule Plus

5000SDSPU/4Unlimited Network Licence Dongle for Schedule Plus

Page 89: Clipsal C-Bus

8989

C-Bus Software

C-Bus OPC Server Software

The C-Bus OPC Server provides an interface between third party software (OPC Clients) and a C-Bus System. The C-Bus OPC Server acts as a gateway for transmitting C-Bus lighting type application information between third party building management systems (such as Honeywell, Johnson, etc.) or Process Control Presentation (SCADA) systems and a C-Bus system.

A C-Bus OPC Server USB dongle must be purchased to unlock the software from an evaluation version to a full working version.

Alternatively, the C-Bus OPC Server is able to recognise licenses manufactured by CITECT (currently only product versions based on the CITECT SCADA Version 7 platform and later are supported).

5000SDOPC2/12 Network Licence Dongle for C-Bus OPC Server

5000SDOPC10/110 Network License Dongle for C-Bus OPC Server

5000SDOPCU/1Unlimited Network License for C-Bus OPC Server

Page 90: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue90 Clipsal C-Bus Product Overview Catalogue90

C-Bus Software

PICED Software

Programming Interface for C-Bus Embedded Devices (PICED) is used to configure the following devices to meet the user’s requirements:

• C-Touch Black and White MKII Touch Screen Controller• C-Touch Spectrum Colour Touch Screen Controller• C-Touch 6.4” Colour Touch Screen Controller• Pascal Automation Controller (PAC)• Wiser Home Controller.

The PICED software features include:

• ability to display many components on many pages• scenes for controlling many loads together• schedules for automatic control of loads• access control to provide security• irrigation control• widget manager for Wiser project creation.

Page 91: Clipsal C-Bus

9191

C-Bus Software

MARPA Software

Multi-Room Audio Rapid Programming Application (MARPA) software is used to configure the C-Bus Multi- Room Audio Matrix Switcher unit. It requires the use of a USB port on the PC to connect to the Matrix Switcher. MARPA software requires the C-Bus Toolkit to be installed. Configure audio sources, audio zones and infrared control.

CIRCA Software

C-Bus Infrared Commissioning Software Application(CIRCA) software is used to commission C-Bus Infrared Devices (5034NIRT). The software allows the user to select IR codes and assign them to particular output channels on an infrared device and make associations between IR codes and C-Bus events. This is achieved by using the C-Bus USB Programming Cable (5100HSCU). The user can import IR device files created by the 5100RP Infrared Reader device. CIRCA software requires that C-Bus Toolkit is installed.

Page 92: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue92 Clipsal C-Bus Product Overview Catalogue92

C-Bus Multi-Room Audio

The C-Bus Multi-Room Audio system allows users to listen to and control audio sources from convenient locations around the home. The system is both simple to install and easy to use. The system has been designed utilising digital audio distribution technology (developed by Clipsal), in conjunction with Clipsal C-Bus core technology for system communication and integration. Clipsal’s digital audio distribution technology allows for noise and interference-free audio reproduction, whilst the C-Bus technology allows the audio products to be seamlessly integrated and used with all existing C-Bus products. For example, volume can be controlled from the same C-Bus switch or touch screen that controls lighting.

In addition, the system allows any input audio source to be made available in any audio zone. Changes to the input audio source can easily be made by the user from a local C-Bus device at any time, regardless of where the audio source equipment (e.g. MP3 player) is physically located. It is compatible with most audio sources and it accommodates standard stereo line level analogue inputs, as well as digital audio TOSLINK inputs. Infrared signals from handheld remote controls can be routed through the system by connecting IR targets and emitters. IR commands can also be stored by the system and activated by programmed C-Bus commands.

The C-Bus Multi-Room Audio system allows a number of different system layout options. This flexibility accommodates for a wide range of customer needs and installation requirements. Two example schematics are shown opposite.

Option A This basic option allows a single audio source to be available to a number of C-Bus Audio Amplifiers and controlled from convenient locations around the home (via any combination of C-Bus input devices). This option requires one Cat. 5 cable for the audio distribution. This cable is cascaded between each audio amplifier.

Option B This option allows more flexibility. Multiple audio sources are made available to all audio zones, with all the audio sources selectable on a zone-by-zone basis via C-Bus Input Devices. This option requires a separate (star wired) Cat. 5 audio cable to each audio amplifier in a zone.

C-Bus Multi-Room AudioSystem Overview

Cabl

e Gu

ide

Gold Pink Red/Black Green

Standard Speaker Cable

C-Bus Cat. 5 Cable

Line Level Stereo Audio Cable

Cat. 5 Cable for Digital Audio

Page 93: Clipsal C-Bus

9393

C-Bus Multi-Room Audio System Overview

Option B

Option A

Page 94: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue94 Clipsal C-Bus Product Overview Catalogue94

C-Bus Multi-Room AudioSystem Overview

560884/2EDeluxe Audio Matrix Switcher, C-Bus Enabled, 4 Stereo Audio Input Sources, Streaming Audio and 8 Digital Audio Output Sources

560884/2Standard Audio Matrix Switcher, C-Bus Enabled, 4 Stereo Audio Input Sources and 8 Digital Audio Output Sources

Audio Matrix Switcher

• Digital audio distribution technology, for noise free audio reproduction

• Stream digital audio from a host PC running C-Bus Ripple Software (deluxe model only)

• 4 stereo analogue audio source inputs

• Onboard dual AM/FM tuners

• Audio sources switched via any C-Bus input device or via the control panel on the front of the matrix switcher

• 8 digital audio zone outputs (~45m for each star wired output)

• Supports audio scenes (8 scenes containing 8 zones)

• Cat. 5 cable connection between matrix switcher and amplifiers

• 2 mono annunciation inputs

• Voice annunciation of channel changes (selectable)

• 1 fibre optic SPDIF input (digital audio compatible)

• 1 custom digital input to allow cascading of units or for connecting an audio distribution unit giving 1 additional stereo analogue input

• C-Bus infrared output (2 zones) for third party equipment control

• Reticulated IR support

• User interface consisting of LCD display and tactile feedback switches

• C-Bus messages control selection of input/output routing

• Contains a C-Bus PC interface

• C-Bus supply voltage: 15–36V d.c. @ 22mA (does not provide power for C-Bus network)

• Configuration set up through USB

• Control via C-Bus input devices, such as C-Bus Wall Switches, Touch Screens, etc.

• Field upgradeable via USB port

• Dimensions: 436mm x 288mm x 80mm

• Designed to be installed where audiovisual equipment is located i.e. AV cabinet or rack

5600ECC-Bus Audio Matrix Switcher streaming upgrade module, suits standard C-Bus Audio Matrix Switcher

Page 95: Clipsal C-Bus

959595

C-Bus Multi-Room Audio System Overview

560011Audio Distribution Unit, 1 Stereo Audio Input Source, 1 Digital Output Source

Audio Distribution Unit

• Distributes a single stereo audio source to C-Bus

Audio Amplifiers via a digitised signal over Cat. 5 cable

• Does not require any C-Bus programming

• 1 stereo analogue audio input source

• 1 digital audio output (cascadable to multiple zones)

• Output can be looped between C-Bus Audio Amplifiers

• Dimensions: 165mm x 50mm x 40mm

5600P24/500AUExternal Power Supply for Audio Distribution Unit, Switch Mode, 24V d.c., 500mA (only required if 560011 used to provide an additional digital input for matrix switcher)

Page 96: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue96 Clipsal C-Bus Product Overview Catalogue96

C-Bus Multi-Room AudioSystem Overview

Audio Amplifiers

• Used in conjunction with the C-Bus Audio Matrix Switcher or the C-Bus Audio Distribution Unit

• Controllable via C-Bus input devices, such as C-Bus Wall Switches, Touch Screens and Wiser Home Controller

• Volume, bass, treble, balance controlled by C-Bus input devices

• Quiet digital audio design

• Stereo 25W RMS per channel. Remote and desktop mounted units (when power supply used) or stereo 10W RMS per channel. Remote mounted unit

• Can be cascaded off one digital audio Cat. 5 input

• Repeater function - digital audio pass through capability (default on)

• Pre-amp output stage for connecting to a third party power amplifier (25W RMS per channel amplifiers only)

• Desktop amplifier includes power ON/OFF, mute, volume and source select buttons; and an infrared target for remote control. Also includes 3.5mm stereo headphone jack

• Desktop amplifier supports dynamic control via long presses of source select buttons on front panel

• 4 x 10W per channel amplifiers can be joined together for installation on a 19” equipment rack tray

• Signal source either:

distributed digital

locally connected line-level analogue

fibre-optic (TOSlink) SPDIF (16bit, 48kHz).

• IR target connection for reticulated IR support

• High efficiency, ~70% at full power

• Dimensions (desktop 25W RMS per channel): 181mm x 216mm x 75mm

• Dimensions (remote 25W RMS per channel): 175mm x 212mm x 71mm

• Dimensions (remote 10W RMS per channel): 120mm x 158mm x 40mm

• C-Bus Supply Voltage: 15–36V d.c. @ 22mA

560110R10W/Channel (RMS) Stereo Audio Amplifier, C-Bus Enabled, Remote Mount Version

560125R/225W/Channel (RMS) Stereo Audio Amplifier, C-Bus Enabled, Remote Mount Version

560125D/225W/Channel (RMS) Stereo Audio Amplifier, C-Bus Enabled, Desktop Mount Version

Page 97: Clipsal C-Bus

979797

C-Bus Multi-Room Audio System Overview

5600P24/3750AUExternal Power Supply for 25W/Channel Audio Amplifier, Switch Mode, 24V d.c, 3.75A

5600P24H3750AExternal Power Supply for Audio Amplifier, Switch Mode, 24V d.c. 72W Continuous Output Power, Ambient Temperature Rating: 60°C (140°F) @ 3A Output

560100EBlank Filling Enclosure where 480mm width is required, suits 10W/Channel Remote Amplifier

5600P24/1250AUPower Supply to suit 10W/Channel Remote Amplifier

560110MBMounting Bracket to suit 10W/Channel Remote Amplifier

Audio Amplifier Accessories

560011BTBluetooth Receiver Module for streaming digital audio from portable devices. Line level audio output

560125MBMounting Bracket to suit 25W/Channel Remote Amplifier

Page 98: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue98 Clipsal C-Bus Product Overview Catalogue98

Premium Audio Speakers

• High-quality audio reproduction — perfect for home theatre, multi-room audio and outdoor audio applications

• Flush-mount design ensures only the front face of the speaker is visible and is flush with the ceiling or wall

• In-ceiling and in-wall speakers come complete with back boxes to maximise and control bass response, while keeping out dust

• Outdoor speakers are waterproof, containing aluminium grilles and mounting brackets plus marine grade stainless steel hardware

C-Bus Multi-Room AudioSystem Overview

AVAILABLE COLOURS

White (WE)

In-Ceiling Speakers

In-Ceiling Speakers - Krix Holographix

• Supplied as a pair

• 3”, full range

• Sensitivity: 87dB

• Frequency response: 90Hz–20kHz

• Power handling: maximum 40W RMS amplifier power

• Impedance: 8 ohms

• Dimensions: 95mm diameter x 108mm deep (83mm diameter cut-out)

5600K01-WEKrix Holographix Speakers (Pair), Circular, In-Ceiling, 3”, Full Range

Page 99: Clipsal C-Bus

999999

C-Bus Multi-Room Audio System Overview

AVAILABLE COLOURS

White (WE)

In-Ceiling Speakers

5600K02-WEKrix Hemispherix Speaker (Single), Circular, In-Ceiling, 4” , 2-Way

In-Ceiling Speakers - Krix Hemispherix• Supplied single

• 4”, 2-way

• Sensitivity: 86dB

• Frequency response: 65Hz–20kHz

• Power handling: maximum 60W RMS amplifier power

• Impedance: 6 ohms

• Dimensions: 240mm diameter x 140mm deep (205mm diameter cut-out)

5600K03-WEKrix Atmospherix Speaker (Single), Circular, In-Ceiling, 5”, 2-Way

In-Ceiling Speakers - Krix Atmosherix• Supplied single

• 5”, 2-way

• Sensitivity: 90dB

• Frequency response: 45Hz–20kHz

• Power handling: maximum 100W RMS amplifier power

• Impedance: 6 ohms

• Dimensions: 280mm diameter x 190mm deep (247mm diameter cut-out)

Page 100: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue100 Clipsal C-Bus Product Overview Catalogue100

C-Bus Multi-Room AudioSystem Overview

Outdoor Speakers - Krix Aquatix

• Supplied as a pair

• 5”, 2-way

• Sensitivity: 87dB

• Frequency response: 70Hz–20kHz

• Power handling: maximum 80W RMS amplifier power

• Impedance: 8 ohms

• Marine grade waterproof

5600K06-WE, 5600K06-BKKrix Aquatix Speakers (Pair), Outdoor, Marine Grade Waterproof, 5”, 2-Way

Pictured: Black

Outdoor Speakers - Krix Tropix• Supplied as a pair

• 6 1/2”, 2-way

• Sensitivity: 87dB

• Frequency response: 55Hz-20kHz

• Power handling: maximum 100W RMS amplifier power

• Impedance: 8 ohms

• Marine grade waterproof

5600K07-WE, 5600K07-BKKrix Tropix Speakers (Pair), Outdoor, Marine Grade Waterproof, 6 1/2”, 2-Way

Pictured: Black

AVAILABLE COLOURS

White (WE)

In-Wall Speakers Outdoor Speakers

Black (BK)

White (WE)

In-Wall Speakers - Krix Ecliptix

• Supplied single

• 4”, 2-way

• Sensitivity: 86dB

• Frequency response: 65Hz–20kHz

• Power handling: maximum 60W RMS amplifier power

• Impedance: 6 ohms

• Dimensions: 305mm high x 220mm wide x 100mm deep

• Cut-out: 276mm high x 188mm wide

5600K04-WEKrix Ecliptix Speaker (Single), Rectangular, In-Wall, 4”, 2-Way

Page 101: Clipsal C-Bus

101101101

C-Bus Multi-Room Audio System Overview

8050LDIR Emitter Lead, Single

8050/2LDIR Emitter Lead, Dual

8050STIR Shelf Target, with 1.8m Cable

8050FTIR Flat Target, with 1.8m Cable

8050TTIR Tube Target, with 1.8m Cable

Multi-Room Audio Accessories

• Infrared accessories to suit C-Bus Multi-Room Audio System

• Supports infrared reticulation features of C-Bus Multi-Room Audio

• Range includes emitters and targets

Accessories

Page 102: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue102 Clipsal C-Bus Product Overview Catalogue102

C-Bus WirelessFor Australia and New Zealand

C-Bus Wireless Control System

The C-Bus Wireless product range incorporates a family of C-Bus Radio Frequency (RF) devices, including wall switches, plug adaptors, remote controls, battery operated wall switches and a gateway to Cat. 5 wired C-Bus.

C-Bus Wireless Wall Switches are designed to easily replace standard, 240V wall switches. They incorporate patented Clipsal technology and are 2-wire devices requiring no Neutral (240V a.c. active and load connections only).

All C-Bus Wireless units incorporate Clipsal C-Bus unique Learn mode functions for programming devices. Wall switches, plug adaptors and the gateway unit can also be programmed via the C-Bus Toolkit software. Multiple C-Bus Wireless units can be linked into a common network using Learn mode or the C-Bus Toolkit software.

Associations can be created between buttons on multiple units, so that a button pressed on one unit will operate a button on another (and the connected lights or other electrical devices).

C-Bus Wireless units include scene capabilities, which allow the user to perform a series of actions across multiple outputs by pressing a single button. For example, on arrival home a homeowner could use a scene to switch on lights in the hallway, kitchen and lounge, and also switch on a heater.

Step 1Enter Learn mode

Step 2Associate buttons between units and program button function

Step 3Exit Learn mode

Grouping C-Bus Wireless Units

The diagrams (right) show two of the many possible basic C-Bus Wireless unit installations. Room A uses stand-alone units, which can be switched via the C-Bus Wireless remote control. Room B uses networked units where buttons on one unit can operate other units or trigger scenes.

Room AStand-alone C-Bus Wireless Units

Room BNetworked C-Bus Wireless Units

Page 103: Clipsal C-Bus

103103

C-Bus Wireless For Australia and New Zealand

Two Output ChannelsBasic Operation

Buttons on a wireless wall switch or plug adaptor are organised in pairs that control the output channels (local control buttons). Remaining pairs (free buttons) are used to control outputs on other units when multiple C-Bus Wireless units are configured as part of a network. For example, the figure to the right shows a 6-button, 2-channel Saturn Wireless Dimmer Wall Switch. Its buttons perform the following functions:

• Buttons 1 and 2 control the first channel. A quick press on either button toggles the channel ON/OFF. A long press on buttons 1 or 2 dims DOWN/UP respectively.

• Buttons 3 and 4 control the second channel.

• Buttons 5 and 6 are unused when the unit is used as a stand-alone unit. They may be used to control outputs on other units when part of a multi-unit network.

When a C-Bus Wireless Wall Switch or Plug Adaptor unit is first installed, it functions as a stand-alone unit. In this basic default mode, the unit functions as a dimmer or switch, depending on the model.

C-Bus Wireless Plug Adaptors have 1 output channel (a single, 240V a.c. socket) and 2 buttons. Wall switch units are available in 1 or 2 output channel versions, with 2, 4, 6 or 8 buttons (8-button, Neo only). Each channel controls 1 or more lights or other electrical devices connected to its output.

3 4

Page 104: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue104 Clipsal C-Bus Product Overview Catalogue104

C-Bus WirelessFor Australia and New Zealand

C-Bus Wireless Networks

To experience the full capabilities of wireless operation, C-Bus Wireless units must be linked together to form a network. To communicate with each other, units within the same network should be located within 15 to 20m of each other. This distance depends on building materials used. Up to 30 units may be connected within the same C-Bus Wireless network.

Page 105: Clipsal C-Bus

105105105

C-Bus Wireless For Australia and New Zealand

C-Bus Wireless Network Security

C-Bus Wireless units can optionally use 128-bit encrypted messages to communicate with each other. This results in a highly secure network.

Nearby C-Bus Wireless Networks

It is possible to have several separate networks present alongside each other without interfering, as each separate C-Bus Wireless network has an automatically assigned and unique ‘house code’.

C-Bus Wireless Modes of Operation

C-Bus Wireless units have 5 major modes of operation: Stand-alone Simple remote controlled Networked Networked with remote Networked with Cat. 5 units

Programming a C-Bus Wireless Unit via C-Bus Toolkit Software

Page 106: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue106 Clipsal C-Bus Product Overview Catalogue106

C-Bus WirelessFor Australia and New Zealand

Mode 1 Stand-Alone

In this mode, C-Bus Wireless Wall Switches and Plug Adaptors act as stand-alone dimmers or switches and make no use of the inbuilt wireless capabilities. No set-up is required for this mode, plug adaptors simply plug into the mains and wireless wall switches are installed by a licensed electrician in place of existing wall switches. The buttons on the units control the local dimming or switching channels of the unit only.

Mode 2 Simple Remote Controlled

In this mode, C-Bus Wireless Wall Switches and Plug Adaptors act as stand-alone dimmers or switches and a C-Bus Wireless Remote Control or battery-operated wall switch operate the units from a distance. This mode is simple to set up and is suitable for small installations where networking is not needed. In this mode the buttons on the wireless wall switch or plug adaptor control the local dimming or switching channels of the unit. The remote control or battery-operated wall switch is linked to buttons on the C-Bus wireless wall switch or plug adaptor using the Learn mode operation. No PC is required.

Mode 3 Networked

In this mode, C-Bus Wireless Wall Switches and Plug Adaptors act as dimmers or switches and multiple C-Bus Wireless units can be linked to each other with the C-Bus Wireless technology. This mode is simple to set up, and is suitable for more complex installations. In this mode, local control buttons control the dimming or switch channel of the unit and may also control other C-Bus Wireless units. Free buttons can control the dimmer or switch channels of other units via a C-Bus Wireless network established using Learn mode operations. The button function is set using Learn mode operation or using the C-Bus Toolkit software.

Page 107: Clipsal C-Bus

107107107

C-Bus Wireless For Australia and New Zealand

Mode 4 Networked with Remote

In this mode, C-Bus Wireless Wall Switches and Plug Adaptors act as dimmers or switches and multiple C-Bus Wireless units can be linked to each other with the C-Bus Wireless technology. Local control buttons control the dimming or switch channel of the unit and may also control other C-Bus Wireless units. Free buttons can control the dimmer or switch channels of other units via a C-Bus Wireless network established using Learn mode operations or C-Bus Toolkit software. Buttons on the wireless remote or battery-operated wall switch are linked to the C-Bus Wireless Wall Switch and Plug Adaptor buttons as desired.

Mode 5 Networked with Cat. 5 Units

The C-Bus Wireless Gateway is used to link a C-Bus

Wireless network to a C-Bus Cat. 5 wired network. It is functionally equivalent to a C-Bus Network Bridge. Using the Gateway, C-Bus Wireless and Cat. 5 networks can communicate and interact with each other. Both wireless and Cat. 5 networks use the same command structure and are 100% compatible.

Page 108: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue108 Clipsal C-Bus Product Overview Catalogue108

C-Bus WirelessFor Australia and New Zealand

C-Bus Wireless Wall Switch Range

• Allow existing 240V a.c. operated wall switches to be replaced with C-Bus Wireless Wall Switches containing C-Bus Wireless technology

• Communicate with other C-Bus Wireless devices using radio frequency wireless messaging and form a C-Bus Wireless network

• Switch buttons enable control of the load/s directly connected to the wall switch and can also control loads connected to other C-Bus Wireless devices

• Each switch button can be programmed to function as an ON/OFF switch, a dimmer or can issue a scene, as well as a number of other options

• Can be controlled via C-Bus Cat. 5 Wired Input Units (via a Gateway Unit), such as touch screens

• Unique C-Bus Wireless House Code

• 128-bit encrypted communications

• Two-wire connection – Active and load (no Neutral required)

• Programmable via C-Bus Learn mode or via C-Bus Toolkit software

• Available in 1-channel and 2-channel versions

• Leading edge and trailing edge dimming units, 1 channel 500VA and 2 channel 250VA per channel

• Relay unit rating: 1 channel 8A (fluorescent), and 2 channel 4A (fluorescent) per channel

• Available in Neo, Saturn and Modena styles

Page 109: Clipsal C-Bus

109109109

C-Bus Wireless For Australia and New Zealand

Wall Switches with Integral Relay Outputs - Saturn Series

5882R8F1AAC-Bus Wireless Wall Switch, 2-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: White

5884R8F1AAC-Bus Wireless Wall Switch, 4-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: Mid-Brown

5886R4F2AAC-Bus Wireless Wall Switch, 6-Button, 2-Channel Relay, 4A (Fluorescent) per Channel Rating

Pictured: Cream

5884R4F2AAC-Bus Wireless Wall Switch, 4-Button, 2-Channel Relay, 4A (Fluorescent) per Channel Rating

Pictured: Mid-Brown

5886R8F1AAC-Bus Wireless Wall Switch, 6-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: Cream

White (GF)

Cream (380)

Mid-Brown (780)

Black (680)

AVAILABLE COLOURS

Saturn Series

Page 110: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue110 Clipsal C-Bus Product Overview Catalogue110

C-Bus WirelessFor Australia and New Zealand

LHC4R8F1C-Bus Wireless Wall Switch, 4-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: Black

LHC6R4F2C-Bus Wireless Wall Switch, 6-Button, 2-Channel Relay, 4A (Fluorescent) per Channel Rating

Pictured: Black

LHC2R8F1C-Bus Wireless Wall Switch, 2-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: White

LHC6R8F1C-Bus Wireless Wall Switch, 6-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: White

LHC4R4F2C-Bus Wireless Wall Switch, 4-Button, 2-Channel Relay, 4A (Fluorescent) per Channel Rating

Pictured: White

Wall Switches with Integral Relay Outputs - Modena Series

White (WH)

Black (BK)

AVAILABLE COLOURS

Modena Series Modena 8000 Series Surrounds

Platinum (M8000HC-PT)

Charcoal (M8000HC-CC)

Blue (M8000HC-DB)

Red (M8000HC-RD)

Champagne (M8000HC-CP)

Gunmetal (M8000HC-GM)

Chrome (M8000HC-CH)

Page 111: Clipsal C-Bus

111111

C-Bus Wireless For Australia and New Zealand

5858R4F2AAC-Bus Wireless Wall Switch, 8-Button, 2-Channel Relay, 4A (Fluorescent) per Channel Rating

Pictured: Battleship Grey/Brushed Aluminium

5858R8F1AAC-Bus Wireless Wall Switch, 8-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: Battleship Grey/Brushed Aluminium

5852R8F1AAC-Bus Wireless Wall Switch, 2-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: Battleship Grey/Brushed Aluminium

5854R4F2AAC-Bus Wireless Wall Switch, 4-Button, 2-Channel Relay, 4A (Fluorescent) per Channel Rating

Pictured: Battleship Grey/Brushed Aluminium

5854R8F1AAC-Bus Wireless Wall Switch, 4-Button, 1-Channel Relay, 8A (Fluorescent) Rating

Pictured: Battleship Grey/Brushed Aluminium

Wall Switches with Integral Relay Outputs - Neo Series

White (WE)

Cream (CM)

Soft Grey (SG)

Battleship Grey/Brushed Aluminium (GB)

Black (BK)

AVAILABLE COLOURS

Neo Series

Page 112: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue112 Clipsal C-Bus Product Overview Catalogue112

C-Bus WirelessFor Australia and New Zealand

5886D2L1AA C-Bus Wireless Wall Switch, 6-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Cream

5886D1L2AAC-Bus Wireless Wall Switch, 6-Button, 2-Channel Leading Edge Dimmer, 250VA per Channel

Pictured: Cream

5884D2L1AA C-Bus Wireless Wall Switch, 4-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Mid-Brown

Wall Switches with Integral Leading Edge Dimmer Outputs - Saturn Series

5884D1L2AAC-Bus Wireless Wall Switch, 4-Button, 2-Channel Leading Edge Dimmer, 250VA per Channel

Pictured: Mid-Brown

5882D2L1AAC-Bus Wireless Wall Switch, 2-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Black

White (GF)

Cream (380)

Mid-Brown (780)

Black (680)

AVAILABLE COLOURS

Saturn Series

Page 113: Clipsal C-Bus

113113

C-Bus Wireless For Australia and New Zealand

LHC4D2L1C-Bus Wireless Wall Switch, 4-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Black

LHC6D1L2C-Bus Wireless Wall Switch, 6-Button, 2-Channel Leading Edge Dimmer, 250VA per Channel

Pictured: Black

LHC2D2L1C-Bus Wireless Wall Switch, 2-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: White

LHC6D2L1C-Bus Wireless Wall Switch, 6-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: White

LHC4D1L2C-Bus Wireless Wall Switch, 4-Button, 2-Channel Leading Edge Dimmer, 250VA per Channel

Pictured: White

Wall Switches with Integral Leading Edge Dimmer Outputs - Modena Series

White (WH)

Black (BK)

AVAILABLE COLOURS

Modena Series Modena 8000 Series Surrounds

Platinum (M8000HC-PT)

Charcoal (M8000HC-CC)

Blue (M8000HC-DB)

Red (M8000HC-RD)

Champagne (M8000HC-CP)

Gunmetal (M8000HC-GM)

Chrome (M8000HC-CH)

Page 114: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue114 Clipsal C-Bus Product Overview Catalogue114

C-Bus WirelessFor Australia and New Zealand

5858D1L2AAC-Bus Wireless Wall Switch, 8-Button, 2-Channel Leading Edge Dimmer, 250VA per Channel

Pictured: Battleship Grey/Brushed Aluminium

5858D2L1AAC-Bus Wireless Wall Switch, 8-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Battleship Grey/Brushed Aluminium

5852D2L1AAC-Bus Wireless Wall Switch, 2-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Battleship Grey/Brushed Aluminium

5854D1L2AAC-Bus Wireless Wall Switch, 4-Button, 2-Channel Leading Edge Dimmer, 250VA per Channel

Pictured: Battleship Grey/Brushed Aluminium

5854D2L1AAC-Bus Wireless Wall Switch, 4-Button, 1-Channel Leading Edge Dimmer, 500VA

Pictured: Battleship Grey/Brushed Aluminium

Wall Switches with Integral Leading Edge Dimmer Outputs - Neo Series

White (WE)

Cream (CM)

Soft Grey (SG)

Battleship Grey/Brushed Aluminium (GB)

Black (BK)

AVAILABLE COLOURS

Neo Series

Page 115: Clipsal C-Bus

115115

C-Bus Wireless For Australia and New Zealand

Wall Switches with Integral Trailing Edge Dimmer Outputs - Saturn Series

5882D2T1AAC-Bus Wireless Wall Switch, 2-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: White

5884D2T1AAC-Bus Wireless Wall Switch, 4-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: Mid-Brown

5886D1T2AAC-Bus Wireless Wall Switch, 6-Button, 2-Channel Trailing Edge Dimmer, 250VA per Channel

Pictured: Cream

5884D1T2AAC-Bus Wireless Wall Switch, 4-Button, 2-Channel Trailing Edge Dimmer, 250VA per Channel

Pictured: Mid-Brown

5886D2T1AAC-Bus Wireless Wall Switch, 6-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: Cream

White (GF)

Cream (380)

Mid-Brown (780)

Black (680)

AVAILABLE COLOURS

Saturn Series

Page 116: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue116 Clipsal C-Bus Product Overview Catalogue116

C-Bus WirelessFor Australia and New Zealand

LHC4D2T1C-Bus Wireless Wall Switch, 4-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: Black

LHC6D1T2C-Bus Wireless Wall Switch, 6-Button, 2-Channel Trailing Edge Dimmer, 250VA per Channel

Pictured: Black

LHC2D2T1C-Bus Wireless Wall Switch, 2-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: White

LHC6D2T1C-Bus Wireless Wall Switch, 6-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: White

LHC4D1T2C-Bus Wireless Wall Switch, 4-Button, 2-Channel Trailing Edge Dimmer, 250VA per Channel

Pictured: White

Wall Switches with Integral Trailing Edge Dimmer Outputs - Modena Series

White (WH)

Black (BK)

AVAILABLE COLOURS

Modena Series Modena 8000 Series Surrounds

Platinum (M8000HC-PT)

Charcoal (M8000HC-CC)

Blue (M8000HC-DB)

Red (M8000HC-RD)

Champagne (M8000HC-CP)

Gunmetal (M8000HC-GM)

Chrome (M8000HC-CH)

Page 117: Clipsal C-Bus

117117

C-Bus Wireless For Australia and New Zealand

5858D1T2AAC-Bus Wireless Wall Switch, 8-Button, 2-Channel Trailing Edge Dimmer, 250VA per Channel

Pictured: Battleship Grey/Brushed Aluminium

5858D2T1AAC-Bus Wireless Wall Switch, 8-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: Battleship Grey/Brushed Aluminium

5852D2T1AAC-Bus Wireless Wall Switch, 2-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: Battleship Grey/Brushed Aluminium

5854D1T2AAC-Bus Wireless Wall Switch, 4-Button, 2-Channel Trailing Edge Dimmer, 250VA per Channel

Pictured: Battleship Grey/Brushed Aluminium

5854D2T1AAC-Bus Wireless Wall Switch, 4-Button, 1-Channel Trailing Edge Dimmer, 500VA

Pictured: Battleship Grey/Brushed Aluminium

Wall Switches with Integral Trailing Edge Dimmer Outputs - Neo Series

White (WE)

Cream (CM)

Soft Grey (SG)

Battleship Grey/Brushed Aluminium (GB)

Black (BK)

AVAILABLE COLOURS

Neo Series

Page 118: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue118 Clipsal C-Bus Product Overview Catalogue118

C-Bus WirelessFor Australia and New Zealand

5080SD-BKMounting Spacer, (Pack of 5)

Pictured: Black

Saturn – Mounting Spacer Neo – Mounting Spacer

5050SD-BKMounting Spacer

Pictured: Black

White (WE)

Cream (CM)

Black (BK)

Soft Grey (SG)

AVAILABLE COLOURS

Page 119: Clipsal C-Bus

119119

C-Bus Wireless For Australia and New Zealand

C-Bus Wireless Battery-Operated Wall Switches - Saturn Series

• Provides control of C-Bus Wireless Wall Switch or Plug Adaptor units remotely

• Provides control of C-Bus devices on a wired network via the C-Bus Wireless Gateway

• Battery operated

• Utilises radio frequency (RF) communication

• Available in 2-button and 6-button units (5 control buttons plus 1 ALL OFF button)

• ALL OFF button provides a convenient way to switch off all buttons associated with the battery-operated wall switch

• Control C-Bus groups and scenes

• 6-button unit incorporates a LED backlit screen for printed button labels

• 17m range (typical)

5886TXWMBA-EBC-Bus Wireless Wall Switch, 6-Button, Battery-Operated

Pictured: Espresso Black

5882TXWMBAC-Bus Wireless Wall Switch, 2-Button, Battery-Operated

Pictured: Pure White

Pure White (PW)

Espresso Black (EB)

Ocean Mist (OM)

AVAILABLE COLOURS

Saturn Series

Page 120: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue120 Clipsal C-Bus Product Overview Catalogue120

C-Bus WirelessFor Australia and New Zealand

C-Bus Wireless Plug Adaptors

• Allow devices normally plugged into 240V a.c. general purpose outlets (for example, lounge or bedside lamps, or AV equipment) to be controlled using C-Bus Wireless technology

• Communicate with other C-Bus Wireless devices (such as Wireless Wall Switches) using radio frequency wireless messaging and form a C-Bus Wireless Network

• C-Bus Wireless Plug Adaptors plug into existing power outlets and the device to be controlled via C-Bus Wireless then piggybacks into the Plug Adaptor. No additions or alterations to existing wiring are required

• Plug into a standard Australian and New Zealand general purpose electrical outlet

• Available in leading edge dimming and trailing edge dimming units, as well as a relay output version

• Integral, easily accessible control/override/programming buttons

• Can be controlled via C-Bus Cat. 5 wired input units (via a Gateway unit), such as touch screens

• Unique C-Bus Wireless House Code

• 128-bit encrypted communications

• Programmable via C-Bus Learn features or via C-Bus Toolkit software

Page 121: Clipsal C-Bus

121121

C-Bus Wireless For Australia and New Zealand

LHC2D2T1C-Bus Wireless Plug Adaptor, 1-Channel Trailing Edge Dimmer, 2A

LHC2D3L1C-Bus Wireless Plug Adaptor, 1-Channel Leading Edge Dimmer, 3A

LHC2R10F1C-Bus Wireless Plug Adaptor, 1-Channel Relay, 10A

5812D2T1AAC-Bus Wireless Plug Adaptor, 1-Channel Trailing Edge Dimmer, 2A

5812D3L1AAC-Bus Wireless Plug Adaptor, 1-Channel Leading Edge Dimmer, 3A

5812R10F1AAC-Bus Wireless Plug Adaptor, 1-Channel Relay, 10A

Relay

Leading Edge Dimmer

Trailing Edge Dimmer

Page 122: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue122 Clipsal C-Bus Product Overview Catalogue122

C-Bus WirelessFor Australia and New Zealand

C-Bus Wireless Remote Control Unit

• Allows control of buttons on C-Bus Wireless Wall Switch and Plug Adaptor units remotely

• Utilises radio frequency (RF) communication

• Does not need to be pointed directly at the unit being controlled

• Capable of controlling up to 10 separate wall switch or plug adaptor buttons

• A single button on a wall switch or plug adaptor can be controlled by up to 2 C-Bus Wireless Remote Controls

• Buttons are organised in 2 banks of 5 buttons. Banks are alternately selected by pressing the ‘Shift’ button

• UP/DOWN buttons allow dimming of the level associated with the last button selected (on dimmer units)

• ALL OFF button provides a convenient way to switch off all buttons associated with the remote control unit

• C-Bus Wireless groups and scenes can be controlled from the remote

• LCD screen and buttons incorporate a blue LED backlight

• Each control button incorporates a clear window for button labelling

• Supplied with pre-labelled stickers for identification of common areas i.e. kitchen, lounge, dining, etc.

• 20–25m range (typical)

LHC8TXRFC-Bus Wireless Handheld Remote Control Unit

5080TXCC-Bus Remote Control Holder (Spare)

5888TXBAC-Bus Wireless Handheld Remote Control Unit with Holder

Page 123: Clipsal C-Bus

123123

C-Bus Wireless For Australia and New Zealand

5800WCGAC-Bus Wireless Gateway

C-Bus Wireless Gateway

• Allows seamless communication between a wired C-Bus network and a C-Bus Wireless network

• Desktop or wall-mounted

• A C-Bus Cat. 5 Cable connected to the wired C-Bus network is plugged into an RJ45 Socket at the rear of the Gateway

• Power for the Gateway is provided by the wired C-Bus network. No additional power source is required

• The connection to a C-Bus Wireless network is accomplished by a C-Bus Learn mode operation

• The connection to a C-Bus Cat. 5 wired network requires the use of the C-Bus Toolkit software

• The Gateway supports routing of messages into and through both wired and wireless networks

• Messages on each network (such as button presses) can be passed through to the adjacent network

• Remote switch function allows control of devices on a wired C-Bus network from C-Bus Wireless Battery-Operated Wall Switches or Remote Controls

Page 124: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue124 Clipsal C-Bus Product Overview Catalogue124

C-Bus HomeSafeSecurity Interface

C-Bus HomeSafe Security Interface

• C-Bus HomeSafe Security Interface suits 8-zone and 16-zone HomeSafe Alarm Panels

• Onboard, direct connection to C-Bus (no C-Bus PC Interface required)

• Supports the C-Bus Security Application command set

• Alarm events such as “armed”, “disarmed” and “alarm” can be used to initiate C-Bus commands, e.g. turn C-Bus controlled lighting ON/OFF

• Ability to map up to 16 alarm events to 16 C-Bus commands

• Ability to arm the security from C-Bus input device (e.g. Touch Screen Controller or Wall Switch)

• True 2-way communication with C-Bus

5400CBC-Bus HomeSafe Security Interface, suits 8-Zone and 16-Zone Alarm Panels

Page 125: Clipsal C-Bus

125125

C-Bus HomeSafeSecurity Interface

5084NL-GF Ulti Saturn Wall Switch

5080CTC3-PW 6.4" Colour Touch Screen Controller

5500PC PC Interface

L5508D1A Dimmer

Keypad

Card Reader

Rewriteable Card

4 Voltage Free Contacts for Door Strikes etc.2

8 or 16 Zones

Available

HomeSafe Panel with C-Bus HomeSafe Security Interface

C-Bus Network

Wireless Pendant1

1 RF SIM required for RF capability.

2 4 channel Relay Card required for Voltage Free Contacts.

Total of 3

(max)

Infrared Sensor (90 Degrees)

Infrared Sensor (90 Degrees)

Page 126: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue126 Clipsal C-Bus Product Overview Catalogue126

Clipsal C-BusTypical Schematics

To o

ther

C-B

us d

evic

es

C-B

us o

utpu

t dev

ices

C-B

us in

put d

evic

es

L550

8D1A

8 C

h D

imm

erL5

512R

VF12

Ch

Rel

ay

5753

LC

-Bus

360

°Fl

ush

Mou

nt D

etec

tor

5085

EDLB

C-B

us e

DLT

W

all S

witc

h50

80C

TC3

Col

our T

ouch

Scr

een

Con

trolle

r

5031

NM

MIR

Lpl

us 5

031N

MS

C-B

us 3

0 M

ech

Wal

l Sw

itch

(in C

2034

VH g

rid)

L550

1RFC

PFa

n C

ontro

l Rel

ay

C-B

us C

able

L550

1RBC

PSh

utte

r Rel

ay

To o

ther

C-B

us d

evic

es

1) E

ach

C-Bu

s ne

twor

k ca

n be

a m

axim

um o

f 100

0m2)

Eac

h C-

Bus

netw

ork

can

have

eith

er a

max

imum

of 1

00 d

evic

es o

r dra

w a

max

imum

of 2

am

p, w

hich

ever

lim

it is

reac

hed

first

.

Typi

cal B

asic

Net

wor

k

Page 127: Clipsal C-Bus

127To o

ther

C-B

us

devi

ces

To o

ther

C-B

us d

evic

es

C-B

us o

utpu

t dev

ices

C-B

us in

put d

evic

es

Ethe

rnet

Sw

itch

5500

PC

C-B

us

RS

-232

inte

rface

5500

CN

2C

-Bus

Eth

erne

t int

erfa

ce(C

NI)

Ethe

rnet

Inte

rface

RS2

32 In

terfa

ce

C-B

us T

rigge

r App

licat

ion

-20

2

C-B

us E

nabl

e A

pplic

atio

n -

203

C-B

us L

ight

ing

Appl

icat

ion

-56

L550

8D1A

8 C

h D

imm

erL5

512R

VF12

Ch

Rel

ay

5753

LC

-Bus

360

°Fl

ush

Mou

nt D

etec

tor

5085

EDLB

C-B

us e

DLT

W

all S

witc

h50

80C

TC3

Col

our T

ouch

Scr

een

Con

trolle

rIP

190

.10.

0.10

1SN

255

.255

.255

.0

5031

NM

MIR

Lpl

us 5

031N

MS

C-B

us 3

0 M

ech

Wal

l Sw

itch

(in C

2034

VH g

rid)

L550

1RFC

PFa

n C

ontro

l Rel

ay

Ethe

rnet

Cab

le

Ethe

rnet

Cab

le

C-B

us C

able

RS2

32 C

able

PC

PC

L550

1RB

CP

Shu

tter R

elay

127

Clipsal C-Bus

Typical SchematicsTy

pica

l Bas

ic N

etw

ork

With

Inte

rfac

es

1) E

ach

C-Bu

s ne

twor

k ca

n be

a m

axim

um o

f 100

0m2)

Eac

h C-

Bus

netw

ork

can

have

eith

er a

max

imum

of 1

00 d

evic

es o

r dra

w a

max

imum

of 2

am

p, w

hich

ever

lim

it is

reac

hed

first

.

Page 128: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue128 Clipsal C-Bus Product Overview Catalogue128

Con

trol R

oom

Equ

ipm

ent

Con

trol R

oom

Equ

ipm

ent

5500

NB

C-B

usN

etw

ork

Brid

ge

DB

C-B

usO

utpu

teq

uipm

ent

5500

NB

C-B

usN

etw

ork

Brid

ge

DB

C-B

usO

utpu

teq

uipm

ent

DB

C-B

usO

utpu

teq

uipm

ent

5500

PC

PC

inte

rface

Uni

t

All

appl

icat

ions

254

253 A

llap

plic

atio

ns

254

252

5500

PS

C-B

us P

S

To o

ther

C-B

us

devi

ces

DB

C-B

usO

utpu

teq

uipm

ent

Ethe

rnet

Sw

itch

5500

PS

C-B

us P

S

5500

PSC

-Bus

PS

5500

PS

C-B

us P

S

5500

PS

C-B

us P

S

5500

CN

2C

-Bus

Eth

erne

t Int

erfa

ce(C

NI)

5080

CTC

3C

olou

r Tou

ch

Scr

een

Con

trolle

r

5080

CTC

3C

olou

r Tou

ch

Scr

een

Con

trolle

r

5080

CTC

3C

olou

r Tou

ch

Scr

een

Con

trolle

r

5080

CTC

3C

olou

r Tou

ch

Scr

een

Con

trolle

r

IP 1

90.1

0.0.

101

SN 2

55.2

55.2

55.0

IP 1

90.1

0.0.

102

SN 2

55.2

55.2

55.0

Typi

cal C

-Bus

Bac

kbon

e

Typi

cal E

ther

net B

ackb

oneR

S23

2 C

able

Ethe

rnet

Cab

le

C-B

us C

able

C-B

us C

able

C-B

us C

able

5500

CN

2C

-Bus

Eth

erne

t Int

erfa

ce(C

NI)

PC

PC

C-B

us in

put d

evic

es

C-B

us in

put d

evic

es

C-B

us in

put d

evic

es

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

C-B

us in

put d

evic

es

To o

ther

C-B

us

devi

ces

5753

LC

-Bus

360

°Fl

ush

Mou

nt

Det

ecto

r50

85E

DLB

C-B

useD

LT

Wal

l Sw

itch

5753

LC

-Bus

360

°Fl

ush

Mou

nt

Det

ecto

r50

85E

DLB

C-B

useD

LT

Wal

l Sw

itch

5753

LC

-Bus

360

°Fl

ush

Mou

nt

Det

ecto

r50

85E

DLB

C-B

useD

LT

Wal

l Sw

itch

5753

LC

-Bus

360

°Fl

ush

Mou

nt

Det

ecto

r50

85E

DLB

C-B

useD

LT

Wal

l Sw

itch

Clipsal C-BusTypical Schematics

Typi

cal N

etw

ork

Join

ing

Page 129: Clipsal C-Bus

129129129

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

All

appl

icat

ions

252

253

All

appl

icat

ions

251

252

5500

NB

C-B

usN

etw

ork

Brid

ge

All

appl

icat

ions

253

254

Net

wor

k 25

4N

etw

ork

253

Net

wor

k 25

2N

etw

ork

251

Clipsal C-Bus

Typical SchematicsTy

pica

l Dai

sy C

hain

Net

wor

ks

Page 130: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue130 Clipsal C-Bus Product Overview Catalogue130

Clipsal C-BusTypical Schematics

1) A

way

Sce

ne2)

Wel

com

esc

ene

3) E

ntry

4) P

orch

1) R

oom

Lig

ht C

ontro

l2)

Sce

ne 1

5085

EDLB

-OM

Bed

1 –

C-B

us

eDLT

Wal

l Sw

itch

5082

NL-

GF

Stu

dy –

Sat

urn

2 Bu

tton

1) R

oom

Lig

ht C

ontro

l2)

Mas

ter O

FF3)

Nig

ht s

cene

4) W

IR5)

BR

Off

scen

e6)

Fan

7) C

urta

in 1

ope

n8)

Cur

tain

1 c

lose

1) B

ed 2

Roo

m L

ight

2) P

assa

ge

1) K

itche

n2)

Kitc

hen

Benc

h3)

Kitc

hen

Join

ery

4) K

itche

n Bl

ock

5) M

eals

6) D

inin

g7)

Out

door

Liv

ing

8) F

amily

5082

NL-

GF

Ens

uite

– S

atur

n 2

Butto

n1)

Dim

up

2) D

im D

own

RLY

01.0

4 -B

athr

oom

Hea

t

RLY

01.0

6 -B

ack

Entry

RLY

01.0

7 -O

utdo

or L

ivin

g

RLY

01.0

8 -W

C

RLY

01.0

9 -L

aund

ry

RLY

01.1

0 -K

itche

n Jo

iner

y

RLY

01.1

1 -W

IR

RLY

01.1

2 -P

assa

ge 2

CR

01.1

-Cur

tain

1 o

pen

CR

01.2

-C

urta

in 1

clo

se

CR

02.1

-Cur

tain

3 o

pen

CR

02.2

-C

urta

in 3

clo

se

FR01

.1-B

ed 1

Fan

L550

1RBC

PC

-Bus

Shu

tter R

elay

size

to

suit

load

size

to

suit

load

size

to

suit

load

size

to

suit

load

240V

Sup

ply

L550

8D1A

C-B

us 1

A D

imm

er m

odul

e

C-B

us C

able

5080

CTC

3Ki

tche

n/ M

eals

-C

olou

r Tou

ch S

cree

n C

ontro

ller

L550

1RBC

PC

-Bus

Shu

tter R

elay

L550

1RFC

PC

-Bus

Fan

Con

trol R

elay

Ethe

rnet

C

able

5200

WH

C2

Stud

y -W

iser

Hom

e C

ontro

ller M

kII

RLY

01.0

4 -B

athr

oom

Fan

RLY

01.0

3 -G

arag

e

RLY

01.0

2 -P

orch

RLY

01.0

1 - E

xter

nal

L551

2RV

F12

Ch

Rel

ay M

odul

e

DIM

01.0

1 -L

ivin

gD

IM01

.02

-Din

ing

DIM

01.0

3 -F

amily

DIM

01.0

4 -M

eals

DIM

01.0

5 -K

itche

n Be

nch

DIM

01.0

6 -K

itche

n

DIM

01.0

7 -S

tudy

DIM

01.0

8 -E

ntry

size

to

suit

load

L550

8D1A

C-B

us 1

A D

imm

er m

odul

e

DIM

02.0

1 -B

ed 1

DIM

02.0

2 -E

nsui

teD

IM02

.03

-Bed

3

DIM

02.0

4 -B

ed 2

DIM

02.0

5 -B

athr

oom

DIM

02.0

6 -P

assa

ge 1

DIM

02.0

7 -S

pare

DIM

01.0

8 -S

pare

size

to

suit

load

1) B

athr

oom

2) B

athr

oom

Fan

3) B

athr

oom

Hea

t4)

All

Off

5084

NL-

GF

Livi

ng –

Sat

urn

4 Bu

tton

1) L

ivin

g Li

ghts

2) W

atch

Mov

iesc

ene

3) P

assa

ge 2

4) T

V O

ff

5084

NL-

GF

Laun

dry–

Sat

urn

4 Bu

tton

1) L

aund

ry2)

Ext

erna

l3)

Bac

k E

ntry

4) A

way

Sce

ne

1) B

ed 3

Roo

m L

ight

2) P

assa

ge

1) W

C2)

Pas

sage

5084

NL-

GF

Entry

– S

atur

n 4

But

ton

5082

NL-

GF

Bed

2–

Satu

rn 2

But

ton

5082

NL-

GF

Bed

3–

Satu

rn 2

But

ton

5084

NL-

GF

Bath

room

– Sa

turn

4 B

utto

n

5082

NL-

GF

WC

– Sa

turn

2 B

utto

n

5085

ED

LB-O

MKi

tche

n –

C-B

us e

DLT

W

all S

witc

h

5080

CTL

2Fa

mily

-B&

W T

ouch

Scr

een

5751

LPo

rch

-90°

PIR

Sen

sor

5751

LW

IR -

90°

PIR

Sen

sor

1) A

way

Sce

ne2)

Wel

com

esc

ene

3) E

ntry

4) G

arag

e

5084

NL-

GF

Gar

age

– Sa

turn

4 B

utto

n

1) D

inin

g2)

Mea

ls3)

Kitc

hen

Bloc

k4)

Out

door

Liv

ing

5) K

itche

n Be

nch

6) K

itche

n Jo

iner

y7)

Kitc

hen

8) F

amily

5085

EDLB

-OM

Din

ing

– C

-Bus

eD

LT

Wal

l Sw

itch

SL50

34N

IRT

Livi

ng –

IR T

rans

mitt

er

Dra

win

g of

W

iser

MkI

I

Typi

cal H

ome

Net

wor

k

Page 131: Clipsal C-Bus

131131131

Clipsal C-Bus

Typical Schematics

Sin

gle

Leve

lTe

nanc

ies

&B

ase

Bui

ldin

gC

ontro

l

5500

NB

Net

wor

k B

ridge

C-Bus Backbone Infrastructure

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

244

239All

appl

icat

ions

5500

NB

Net

wor

k B

ridge

244

239All

appl

icat

ions

5500

NB

Net

wor

k B

ridge

Leve

l 1

Leve

l 2

Leve

l 3

Leve

l 4

Leve

l 5

Leve

l 6

Leve

l 7

Leve

l 8

Gro

und

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

5500

PS

C-B

us 3

50m

A P

S

9 x

5500

CN

2C

-Bus

E

ther

net

Inte

rface

(CN

I)

Eth

erne

t Sw

itch

IP 1

90.1

0.0.

101-

>190

.10.

0.10

9SN

255

.255

.255

.0

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-59

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-58

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-57

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-55

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-54

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-53

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-52

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-62

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-62

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-60

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-59

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-58

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-57

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-55

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-54

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-53

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-52

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-61

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

Eth

erne

t C

able

C-B

us C

able

Ethe

rnet

Cab

le

PC

5500

CN

255

00C

N2

5500

CN

2

5500

CN

255

00C

N2

5500

CN

2

5500

CN

255

00C

N2

5500

CN

2

Typi

cal M

ulti

Stor

ey E

ther

net B

ackb

one

1) A

ll nu

mbe

rs a

re d

ecim

al

Page 132: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue132 Clipsal C-Bus Product Overview Catalogue132

Ethe

rnet

sw

itch

PC

Blo

ck A

5500

CN

2C

-Bus

Eth

erne

t Int

erfa

ce(C

NI)

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

Bloc

k B

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

Bloc

k C

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

NB

C-B

usN

etw

ork

Brid

ge

5500

PAC

APA

C L

ogic

con

trolle

r55

00PA

CA

PAC

Log

ic c

ontro

ller

5500

PAC

APA

C L

ogic

con

trolle

r

Sch

edul

e Pl

us

Eth

erne

t C

able

Ethe

rnet

C

able

Ethe

rnet

C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

5500

CN

2C

-Bus

Eth

erne

t Int

erfa

ce(C

NI)

5500

CN

2C

-Bus

Eth

erne

t Int

erfa

ce(C

NI)

Clipsal C-BusTypical Schematics

Op

tio

n. I

nclu

de a

PAC

and

4-g

ang

as a

min

imum

in e

ach

bloc

k as

a fa

il-sa

fe in

the

even

t Sch

edul

e Pl

us, P

C or

Net

wor

k fa

ilure

. Sch

edul

e Pl

us is

set

up

a m

aste

r, PA

C as

sl

ave,

with

Sch

edul

e Pl

us s

endi

ng a

hea

rt be

at to

the

PAC.

If P

AC m

isse

s 3

cons

ecut

ive

hear

tbea

ts th

e PA

C w

ill b

ecom

e th

e m

aste

r. 4-

butto

n sw

itch

can

be u

sed

a m

aste

r ov

errid

e fo

r eac

h flo

or

Typi

cal M

ulti

Bui

ldin

g Et

hern

et B

ackb

one

Page 133: Clipsal C-Bus

133

Main HeadingSub Heading

Clipsal C-Bus Product Overview Catalogue133

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-60

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-59

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-58

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-57

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-55

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-54

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-53

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-52

Sin

gle

Leve

lTe

nanc

ies

&B

ase

Bui

ldin

gC

ontro

l

5500

NB

Net

wor

k B

ridge

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-59

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-58

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-57

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-55

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-54

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-53

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

App

licat

ion

-52

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

5500

NB

Net

wor

k B

ridge

All

appl

icat

ions

141

239

Trig

ger A

pplic

atio

n -

202

Ena

ble

App

licat

ion

-20

3

Ligh

ting

Appl

icat

ion

-62

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-62

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

244

239All

appl

icat

ions

5500

NB

Net

wor

k B

ridge

Trig

ger A

pplic

atio

n -

202

Enab

le A

pplic

atio

n -

203

Ligh

ting

Appl

icat

ion

-61

244

239All

appl

icat

ions

5500

NB

Net

wor

k B

ridge

Leve

l 1

Leve

l 2

Leve

l 3

Leve

l 4

Leve

l 5

Leve

l 6

Leve

l 7

Leve

l 8

Gro

und

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

To o

ther

C-B

us

devi

ces

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

DB

C-B

usO

utpu

tequ

ipm

ent

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PSC

-Bus

35

0mA

PS

5500

PS

C-B

us

350m

A P

S

5500

PSC

-Bus

35

0mA

PS

5500

PS

C-B

us

350m

A P

S

5500

PS

C-B

us

350m

A P

S

5500

PS

C-B

us

350m

A P

S

5500

PSC

-Bus

35

0mA

PS

5500

PS

C-B

us

350m

A P

S

5500

PS

C-B

us

350m

A P

S

5500

PSC

-Bus

35

0mA

PS

9 X

5500

NB

Net

wor

k Br

idge

5500

PCPC

inte

rface

Uni

t

Allapplications

RS2

32 C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

C-B

us C

able

PC

1) A

ll nu

mbe

rs a

re d

ecim

al2)

A P

C w

ith S

ched

ule

Plus

sof

twar

e in

stal

led

on th

e ba

ckbo

ne

will

pro

vide

the

C-Bu

s ne

twor

ks w

ith g

reat

er fl

exib

ility

allo

win

g fo

r mes

sage

rout

ing

betw

een

all n

etw

orks

Typi

cal M

ulti-

Stor

ey C

-Bus

Bac

kbon

eClipsal C-Bus

Typical Schematics

Page 134: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue134

0-10

Vol

t con

trol c

ircui

tsup

to 2

0 ba

llast

s pe

rch

anne

l

L550

4AM

P4

chan

nela

nalo

gue

outp

ut

mod

ule DIM

1.1

DIM

1.2

DIM

1.3

DIM

11.4

DIM

1.1

DIM

1.2

DIM

1.2

DIM

1.3

L550

4RVF

4 ch

anne

l Rel

ay m

odul

e

size

to s

uit l

oad

2 w

ire D

SI c

ontro

lup

to 1

00 B

alla

sts

per c

hann

el

size

to s

uit l

oad

DSI

1.1

size

to s

uit l

oad

size

to s

uit l

oad

DAL

I1.1

DAL

I Sw

itch

Gro

up 1

DAL

I PS

DSI

1.2

DS

I1.3

DSI

1.4

DSI

1.5

DSI

1.6

DSI

1.7

DSI

1.8

DAL

I PS

2 w

ire D

ALI c

ontro

lup

to 6

4 B

alla

sts

per l

ine

DAL

I1.2

DAL

I1.3

DAL

I1.4

L550

8DS

I8

Ch

DSI

Gat

eway

5502

DAL

2 C

hann

el D

ALI G

atew

ay

Typi

cal

C-B

us /

0-10

V D

imm

ing

Typi

cal

C-B

us /

DS

I Dim

min

g

Typi

cal

C-B

us /

DA

LI D

imm

ing

1.5m

m T

win

AC P

ower

1.5m

m T

win

AC P

ower

C-B

us C

able

1.5m

m T

win

AC P

ower

AC P

ower

size

to s

uit l

oad

size

to s

uit l

oad

size

to s

uit l

oad

Ligh

t Fitt

ing

Ligh

t Fitt

ing

Ligh

t Fitt

ing

Clipsal C-BusTypical Schematics

The

DALI

Bal

last

s ar

e to

be

addr

esse

d w

ith D

ALI c

omm

issi

onin

g so

ftwar

e co

nnec

ted

dire

ctly

to th

e DA

LI B

us, n

ot v

ia th

e C-

Bus

com

mis

sion

ing

softw

are.

Thi

s so

ftwar

e, a

nd a

ny a

ssoc

iate

d ha

rdw

are,

is

best

pro

vide

d by

the

balla

st m

anuf

actu

rer t

hus

prev

entin

g w

arra

nty

disp

utes

in th

e ev

ent o

f inc

orre

ct

balla

st o

pera

tion.

Typi

cal F

luor

esce

nt D

imm

ing

Page 135: Clipsal C-Bus

135

Typi

cal R

GB

Con

trol

135135

Clipsal C-Bus

Typical Schematics

OSRAM

OT DALI

RGB Controller

L N D D

+

R -

G -

B -

PWM

Linearlight Colourmix LED strip

350Hz

Typical

Max 48 watt per channel at 24Vdc

DALI addresses preset to;

Red: address 0

Green: address 1

Blue: address 2

RLY1.1

RLY1.2

RLY1.3

RLY1.4

ADIM1.1- Analogue RED

ADIM1.2 -Analogue GREEN

ADIM1.3 -Analogue BLUE

ADIM1.4 -Spare

L5504RVF

4 channel

relay module

OSRAM

OT RGB LED

Controller

Common Cathode to

L5504AMP

- + + + - +OT PS

10 –24 Vdc

+

R -

G -

B -

PWM

Linearlight Colourmix LED strip

350Hz

Typical

Max 48 watt per channel at 24Vdc

L5504AMP

4 channelanalogue output

module

Typical

C-Bus / 0-10V to RGB

Typical

C-Bus/DALI to RGB C-Bus

Cable

DALI PS

DALI PS

5502DAL

2 Channel DALI Gateway

size to suit load

size to suit load

size to suit load

size to suit load

5500DMX

DMX Gateway

LN

B +

B +

B +B -

BA

LED Strip

9 Watt RGB

DMXi

Shielded twisted pair

RGBox 24V 50W

LON/OFF

COLOUR

NB +

B +

B +B -

RGBox 24V 50W

GND DATA-DATA+

size to suit load

Typical

C-Bus / DMX to RGB

The

DALI

Bal

last

s ar

e to

be

addr

esse

d w

ith D

ALI c

omm

issi

onin

g so

ftwar

e co

nnec

ted

dire

ctly

to th

e DA

LI B

us, n

ot v

ia th

e C-

Bus

com

mis

sion

ing

softw

are.

Thi

s so

ftwar

e, a

nd a

ny a

ssoc

iate

d ha

rdw

are,

is

best

pro

vide

d by

the

balla

st m

anuf

actu

rer t

hus

prev

entin

g w

arra

nty

disp

utes

in th

e ev

ent o

f inc

orre

ct

balla

st o

pera

tion.

Page 136: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue136 Clipsal C-Bus Product Overview Catalogue136

Clipsal C-BusTypical Schematics

R-0

1 H

eat

R-0

2 C

ool

R-0

3 F1

R-0

4 F2

Con

trol C

omm

on

R-0

1 A/

C P

ower

R-0

2 R

-03

R-0

4

Air C

onor

HVA

CSy

stem

Low

Lev

el c

ontro

l rel

ay

Pow

er s

witc

hing

Con

tact

or(s

ingl

e or

m

ultip

hase

)To

sui

t A/C

sy

stem

Air C

onor

HVA

CSy

stem

5034

NIR

T IR

tran

smitt

er50

80C

TC3

Col

our T

ouch

Scr

een

Con

trolle

rL550

4RV

F C

-Bus

Rel

ay m

odul

e

L550

4RVF

C

-Bus

Rel

ay m

odul

e

L550

4AU

XA

uxili

ary

inpu

t mod

ule

Hig

h Le

vel u

ni-d

irect

iona

l IR

co

ntro

l

Air C

onor

HVA

CSy

stem

RS-

232

seria

l con

nect

ion

5500

PAC

APa

scal

Aut

omat

ion

Con

trolle

r50

80C

TC3

Col

our T

ouch

Scr

een

Con

trolle

r

Hig

h Le

vel u

ni-d

irect

iona

l RS

-232

se

rial c

ontro

l

Tem

p.co

ntro

ller

Tem

p.co

ntro

ller

Tem

p.co

ntro

ller

size

to

suit

load

size

to

suit

load

size

to

suit

load

size

to

suit

load

Dry

con

tact

A/C

st

atus

feed

back

co

ntro

l

Dry

con

tact

A/C

co

ntro

l inp

uts

pres

s &

hold

for s

etup

pres

s &

hold

for t

imer

pres

s &

hold

for s

etba

ck

fan

type

5070

THB

RC

-Bus

The

rmos

tat

Hea

t C

ool

F1

F2

Con

trol C

omm

on

F3

Low

Lev

el C

-Bus

The

rmos

tat

Air

Con

orH

VAC

Syst

em

size

to

suit

load

size

to

suit

load

C-B

us C

able

240V

AC

Sup

ply

24V

AC P

S

Inte

rfac

e m

etho

d an

d op

erat

ion

is d

epen

dant

on

the

type

of H

VAC

or A

/C s

yste

m s

uppl

ied

to th

e in

stal

latio

n. In

som

e ca

ses

IR c

odes

or R

S-23

2 co

ntro

l com

man

d st

rings

are

diffi

cult

to o

btai

n or

in

terf

ace

with

. HVA

C or

A/C

sys

tem

kno

wle

dge

is

nece

ssar

y.

Typi

cal A

/C c

ontro

l

Page 137: Clipsal C-Bus

137137137

Clipsal C-BusTypical Schematics

LCP-

001

Entry

LCP-

007

Bath

room

MS

R-0

01La

undr

y

LCP-

013

Kitc

hen/

Din

ing

CTR

L-00

4L5

504A

UX

Aux

iliary

Inpu

tDev

ice

1) A

way

Sce

ne2)

Wel

com

esc

ene

3) C

orrid

or4)

Mas

ter O

ff

LCP

-006

Mas

ter B

edR

HS

1) R

oom

Lig

ht C

ontro

l2)

Nig

ht S

cene

3) C

urta

in 6

ope

n4)

Cur

tain

6 c

lose

5) C

urta

in 7

ope

n6)

Cur

tain

7 c

lose

7) D

ures

s

1) R

oom

Lig

ht C

ontro

l2)

Sce

ne 1

LCP

-002

Mas

ter B

edM

ain

LCP

-011

Livi

ng D

inni

ng

LCP

-004

M

aste

r Bed

LHS

LCP-

009

Bed

1M

aste

r

LCP-

005

Bed

1 R

HS

1) R

oom

Lig

ht C

ontro

l2)

Mas

ter O

FF3)

Nig

ht s

cene

4) J

oine

ry li

ght

5) M

aste

r BR

sce

ne6)

Dur

ess

7) C

urta

in 1

ope

n8)

Cur

tain

2 c

lose

1) B

ed 1

Roo

m L

ight

2) S

cene

1

Sm

oke

Det

ecto

rIn

puts

MS

R-0

02Ba

thro

om

MS

R-0

03En

suite

OP

TIO

NA

LR

S-23

2

1) L

ivin

g lig

hts

2) D

inin

g lig

hts

3) K

itche

n4)

Kitc

hen

Join

ery

5) H

allw

ay6)

Sce

ne 1

7) A

ll cu

rtain

s cl

ose

8) A

ll cu

rtain

s op

en

1) D

im u

p2)

Dim

Dow

n

LCP-

003

Bed

1LH

S

1) R

oom

Lig

ht C

ontro

l2)

Mas

ter O

FF3)

Nig

ht s

cene

4) J

oine

ry li

ght

5) M

aste

r BR

sce

ne6)

Dur

ess

7) C

urta

in 1

ope

n8)

Cur

tain

2 c

lose

LCP-

008

Ens

uite

1) D

im u

p2)

Dim

Dow

n

1) R

oom

Lig

ht C

ontro

l2)

Nig

ht S

cene

3) C

urta

in 6

ope

n4)

Cur

tain

6 c

lose

5) C

urta

in 7

ope

n

LCP-

010

Mas

ter B

edsi

tting

1) R

oom

ligh

t con

trol

2) S

cene

LCP-

012

Stu

dy

1) R

oom

ligh

t con

trol

2) S

cene

3) C

urta

in 2

ope

n4)

Cur

tain

2 c

lose

Alar

m in

put

CTL

-003

IR T

rans

mitt

er

DB1

DIM

01.0

1 - M

aste

r Bed

sitt

ing

DB

1DIM

01.0

2 - M

aste

r Bed

Mai

n

DB1

DIM

01.0

3 - M

aste

r Bed

join

ery

DIM

01.0

4 -S

tudy

DIM

01.0

5 -E

nsui

te

DIM

01.0

6 -D

inni

ng

DIM

01.0

7 –

Bed

2

DIM

01.0

8 –

Bat

hroo

m

DIM

02.0

1 -

Livi

ng ro

omD

IM02

.02

- Ent

ry

DIM

02.0

3 -K

itche

n m

ain

DIM

02.0

4 - K

itche

n be

nch

CR

01.1

-Cur

tain

1 o

pen

CR

01.2

-C

urta

in 1

clo

se

CR

02.1

-Cur

tain

3 o

pen

CR

02.2

-C

urta

in 3

clo

se

CR

03.1

-Cur

tain

5 o

pen

CR

03.2

-C

urta

in 5

clo

se

CR

04.1

-Cur

tain

7 o

pen

CR

04.2

-C

urta

in 7

clo

se

CR

01L5

501R

BCP

C-B

us S

hutte

r Rel

ayIn

tern

et

Ethe

rnet

C

able

5200

WH

C2

Wis

er H

ome

Con

trolle

r MkI

I

size

to

suit

load

size

to

suit

load

size

to

suit

load

size

to

suit

load

size

to

suit

load

size

to

suit

load

C-B

us C

able

240V

Sup

ply

L550

4D2A

C-B

us 2

A D

imm

er m

odul

e

L550

8D1A

C-B

us 1

A D

imm

er m

odul

e

C-B

us C

able

5080

CTC

3C

olou

r Tou

ch S

cree

n C

ontro

ller

CR

02L5

501R

BCP

C-B

us S

hutte

r Rel

ay

CR

03L5

501R

BCP

C-B

us S

hutte

r Rel

ay

CR

04L5

501R

BC

PC

-Bus

Shu

tter R

elay

Dra

win

g of

W

iser

MkI

I

Typi

cal A

part

men

t Net

wor

k

Page 138: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue138

10 a

mp

CB

10 a

mp

CB

DSI

01L5

508D

SI8

Ch

DS

I Gat

eway

RLY

01L5

512R

VF12

Ch

Rel

ay M

odul

e

RLY

1.01

– C

orrid

or S

/W

RLY

1.03

–R

ecep

tion

RLY

1.05

– C

orrid

or N

/E

RLY

1.07

–Lu

nch

Roo

m

RLY

1.02

–R

ecep

tion

Wal

l LTS

RLY

1.04

–R

ecep

tion

Sto

rage

RLY

1.06

– M

ain

open

offi

ce a

rea

RLY

1.08

–M

ale

Toile

t

RLY

1.09

–Fe

mal

e To

ilet

RLY

1.10

–S

pare

RLY

1.11

– S

pare

RLY

1.12

–S

pare

DS

I1.0

1 -O

pen

offic

e ar

ea e

ast

DS

I1.0

3 -B

reak

out r

oom

DS

I1.0

5 -B

oard

room

scr

een

DS

I1.0

7 -P

lant

room

DS

I1.0

2 -O

ffice

1

DS

I1.0

4 -O

ffice

2

DS

I1.0

6 -B

oard

room

DS

I1.0

8-s

pare

DB

1.01

Rec

eptio

n

LCP

07SC

5000

CT2

B&W

Tou

ch S

cree

nM

SR06

5753

PEIR

L36

0° M

ulti

Sen

sor

LCP

01SC

5031

NL

1 B

utto

n S

limlin

e W

all S

witc

h

MSR

1057

53PE

IRL

360°

Mul

ti S

enso

r

LCP

02SC

5031

NL

1 B

utto

n S

limlin

e W

all S

witc

h

Offi

ce 1

MSR

1157

53PE

IRL

360°

Mul

ti S

enso

r

LCP

03SC

5031

NL

1 B

utto

n S

limlin

e W

all S

witc

h

Bre

akou

t Roo

m

MSR

1257

53PE

IRL

360°

Mul

ti S

enso

r

LCP

04S

C50

31N

L1

But

ton

Slim

line

Wal

l Sw

itch

Offi

ce 2

MSR

1357

53PE

IRL

360°

Mul

ti Se

nsor

Lunc

h R

oom

MSR

1457

53PE

IRL

360°

Mul

ti Se

nsor

Mal

e To

ilet

MSR

1557

53PE

IRL

360°

Mul

ti S

enso

r

Fem

ale

Toile

t

Ope

n O

ffice

Are

a

MSR

0357

53PE

IRL

360°

Mul

ti Se

nsor

MSR

0557

53PE

IRL

360°

Mul

ti S

enso

r

MSR

0457

53PE

IRL

360°

Mul

ti Se

nsor

MS

R02

5753

PEI

RL

360°

Mul

ti Se

nsor

MS

R01

5753

PEI

RL

360°

Mul

ti Se

nsor

MSR

0957

53PE

IRL

360°

Mul

ti S

enso

r

Cor

ridor

S/W

OC

S01

5751

L90

° PI

R S

enso

r

MSR

0757

53PE

IRL

360°

Mul

ti S

enso

r

MS

R08

5753

PEI

RL

360°

Mul

ti Se

nsor

Boar

d R

oom

LCP

0650

85E

DLB

C-B

us e

DLT

W

all S

witc

h

LCP

0550

85ED

LBC

-Bus

eD

LT

Wal

l Sw

itch

C-B

us C

able

C-B

us C

able

240V

AC

Sup

ply

PS01

5500

PS

C-B

us 3

50m

A P

S

Clipsal C-BusTypical Schematics

Typi

cal O

ffice

Net

wor

k

Page 139: Clipsal C-Bus

139

Ligh

ting

Con

trol F

ront

End

-A

llow

s co

mm

issi

onin

g an

d m

aint

enan

ce o

f lig

htin

g co

ntro

l-P

rovi

des

Em

erge

ncy

Ligh

ts te

st re

ports

-Sto

res

all l

ight

ing

cont

rol D

ata

and

conf

igur

atio

n in

form

atio

n

Bui

ldin

g M

anag

emen

t Sys

tem

-Pro

vide

s en

d us

er in

terfa

ce to

ligh

ting

cont

rol s

yste

m-D

ispl

ays

occu

panc

y st

atus

and

DAL

I erro

rs to

use

r-S

igna

ls s

tart

of d

ay a

nd e

nd o

f day

to li

ghtin

g co

ntro

l sys

tem

-Pro

vide

s ac

cess

car

d ov

errid

e co

mm

ands

to li

ghtin

g co

ntro

l sys

tem

5500

PC

C-B

us R

S-23

2 in

terfa

ce

(PC

I)

5500

CN

2C

-Bus

Eth

erne

t int

erfa

ce(C

NI)

0073

0835

1Xe

nta

913

(Sch

neid

er E

lect

ric)

Eth

erne

t sw

itch

Ethe

rnet

Cab

le

OP

C S

erve

r-P

rovi

des

lam

p, b

alla

st, g

roup

and

line

info

rmat

ion

back

to B

MS

-Rec

eive

s co

mm

ands

from

BM

S a

nd is

sues

them

to li

ghtin

g sy

stem

Clip

sal 5

000B

AC

net

C-B

us\B

AC

net G

atew

ay

BAC

NET

Gat

eway

24V

d.c

5500

PCC

-Bus

RS

-232

inte

rface

(P

CI)

Sch

edul

e Pl

usX

enta

913

RS-

232

Cab

le

C-B

us C

able

PC

PC

C-B

us C

able

RS-

232

Cab

le

C-B

us C

able

Clipsal C-BusTypical Schematics

Typi

cal B

MS

Inte

grat

ion

BMS

Inte

rfac

e op

tions

with

C-B

us

Page 140: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue140

Vid

eo S

witc

h

DVD

Set t

op b

ox

Com

pone

nt

Com

pone

nt

*550

0CN

2C

-Bus

Eth

erne

t int

erfa

ce(C

NI)

5500

PCC

-Bus

RS

-232

inte

rface

(P

CI)

RS-

232

Cab

le

AV P

roce

ssor

Ethe

rnet

Cab

le

*RS

-232

C-B

us c

an p

rovi

de fe

edba

ck to

the

AV P

roce

ssor

Vide

o Sw

itch

DV

D

Set t

op b

ox

Com

pone

nt

Com

pone

nt

AV P

roce

ssor

Ethe

rnet

Sw

itch

*RS

-232

*Eth

erne

t

To C

-Bus

ligh

ting

cont

rol u

nits

Aud

io V

isua

l Rac

k

Audi

o Vi

sual

Rac

k

C-B

us c

an p

rovi

de fe

edba

ck to

the

AV P

roce

ssor

To A

udio

Vis

ual u

ser d

evic

e

To A

udio

Vis

ual u

ser d

evic

e

L550

8D1A

8 C

h 1A

Dim

mer

C-B

us C

able

C-B

us C

able

L550

8D1A

8 C

h 1A

Dim

mer

Clipsal C-BusTypical Schematics

Typi

cal A

udio

Vis

ual I

nteg

ratio

n

Third

par

ty A

V in

tegr

atio

n is

nee

ded

whe

n C-

Bus

has

been

sel

ecte

d NO

T to

be

the

prim

ary

cont

rol m

etho

d of

the

AV e

quip

men

t. Th

e th

ird p

arty

AV

equi

pmen

t can

com

mun

icat

e w

ith C

-Bus

via

; - A

Clip

sal P

C In

terf

ace

(PCI

) usi

ng th

e RS

2332

pro

toco

l. - A

Cl

ipsa

l Net

wor

k In

terf

ace

(CNI

) usi

ng T

CP/IP

. The

se c

onne

ctio

ns w

ill a

llow

third

par

ty A

V eq

uipm

ent t

o co

ntro

l C-B

us a

t a h

igh

leve

l. Th

e PC

I or C

NI c

an b

e m

ount

ed w

ithin

the

Audi

o Vi

sual

rack

, or a

ltern

atel

y be

loca

ted

loca

lly to

the

third

par

ty c

ontro

ller.

Low

leve

l int

egra

tion

is p

ossi

ble

with

the

use

of C

lipsa

l’s L

5108

ELVP

8 C

hann

el E

xtra

Low

Vol

tage

Rel

ay. *

The

5500

CN (C

NI) i

s ca

pabl

e of

util

isin

g on

e TC

P so

cket

onl

y at

a ti

me.

Page 141: Clipsal C-Bus

141

Uni

tIR

1C

-Bus

IR2

Fluo

resc

ent L

ight

Fitt

ing

Fluo

resc

ent L

ight

Fitt

ing

Ethe

rnet

Sw

itch

Proj

ecto

r

Fluo

resc

ent L

ight

Fitt

ing

Vide

o Sw

itch

DV

D

Set t

op b

ox

Spea

ker

C-B

usC

ompo

nent

Des

kPC

Inpu

t

VGA

+ L&

R

Spea

ker

5080

CTC

3C

olou

r Tou

ch

Scre

en C

ontro

ller

L550

8DSI

8 C

h D

SI G

atew

ay

5500

PAC

APA

C L

ogic

con

trolle

r

5500

PSC

-Bus

PS

Spe

aker

Cab

le

1.5m

m T

win

Ethe

rnet

Cab

le

C-B

us C

able

C-B

us C

able

C-B

us C

able

RS2

32V

GA

RS

232

5034

NIR

T4

Ch

Infra

-red

Tra

nsm

itter

RC

A

Com

pone

nt

5085

ED

LBC

-Bus

eD

LT

Wal

l Sw

itch

Clipsal C-BusTypical Schematics

Aud

io V

isua

l Int

egra

tion

Page 142: Clipsal C-Bus

Clipsal C-Bus Product Overview Catalogue142 Clipsal C-Bus Product Overview Catalogue142

Notes

Page 143: Clipsal C-Bus

143143

Notes

Page 144: Clipsal C-Bus

You can find this brochure and many others online in PDF format at: clipsal.comFollow the links off the home page or access the following page directly: clipsal.com/brochures

C3-

016

Schneider Electric (Australia) Pty Ltd

33-37 Port Wakefield Road, Gepps Cross, South Australia 5094

PO Box 132, Enfield Plaza, South Australia 5085

Telephone: (08) 8161 0511 Facsimile: (08) 8161 0900 Email: [email protected] Internet: www.clipsal.com

National Customer Care Enquiries: 1300 2025 25National Customer Care Facsimile: 1300 2025 56

International Enquiries International Sales and Marketing Email: [email protected]

Schneider Electric (NZ) Ltd38 Business Parade South, Highbrook, East Tamaki, Manukau 2013, NEW ZEALAND

Telephone: + 64 9 829 0490Facsimile: + 64 9 829 0491Internet: www.schneider-electric.com

Customer CareFreephone: 0800 652 999Freefax: 0800 101 152Email: [email protected] Internet: www.clipsal.co.nz

© 2013 Schneider Electric. All Rights Reserved.

Trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.

Schneider Electric (Australia) Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

This document has been printed using FSC Mix Certified paper. ISO 14001 environmental management system in use at mill.

CLIPCOM26215 June 2013