Clinical and laboratory remoutning

74

Transcript of Clinical and laboratory remoutning

Page 1: Clinical and laboratory remoutning
Page 2: Clinical and laboratory remoutning

Clinical and Laboratory Remounting

in Complete Dentures

Submitted by:

Dr.Pallavi Chavan

2nd year PG

Page 3: Clinical and laboratory remoutning

Introduction• Complete dentures are prosthetic replacements for lost

natural teeth and lost soft and bony tissues, which are fabricated in order to restore impaired or lost functions and appearance

• Fabrication of complete dentures comprises various variables whose precise execution is of crucial importance for achieving success with fabricated dentures

Page 4: Clinical and laboratory remoutning

• The efficiency and comfort that a patient experiences using complete dentures depends to a large extent on the harmony of the occlusion

• Occlusion established during try-in stage is subject to change because of inaccuracies incorporated during construction of dentures

Page 5: Clinical and laboratory remoutning

• Minor faults can be corrected by selective grinding with dentures in patient's mouth, if a split cast remount procedure was used immediately after the dentures were processed.

• However, a general dental practice survey revealed that less than 5% of dentists use the split cast procedure to rectify the errors of processing

Page 6: Clinical and laboratory remoutning

• Prosthodontist’s recommend a remount procedure for identification and correction of occlusal errors in complete dentures rather than the more common practice of placing the articulating paper intra orally, followed by spot grinding

at the chair side

• However, There is no evidence to support such recommendations

Page 7: Clinical and laboratory remoutning

What is Remounting??

Definition:

• Remount procedure : Any method used to relate restorations to an articulator

for analysis and/or to assist in development of a plan for occlusal equilibration or reshaping.

• Remount record index : A record of maxillary structures affixed to the

mandibular member of an articulator useful in facilitating subsequent transfers

Page 8: Clinical and laboratory remoutning

Causes of Errors in Occlusion :1. Incorrect Registration of Centric Occlusion:• Reason A :

During JR, when occlusal rims are brought together cause uneven pressure due to premature contact in the 2nd

molar or incisor region

Compression of mucosa

Displaces the mucosa away from the region of premature contacts

Page 9: Clinical and laboratory remoutning

But, on plaster models there is no compression of tissues

Thus, different relation in mouth and articulator

Thus, an error is established which is passed through try-in and processing stages

At denture insertion the dentures contact only in areas of these premature contacts

Causes of errors in occlusion

Page 10: Clinical and laboratory remoutning

Incorrect registration of centric occlusion

• Reason B: Imperfectly fitting record bases can cause movement of rims

while recording centric The dentures will have slightly inaccurate centric occlusion

relation and will tend to move on the ridges , causing soreness

• Reason C: The models may not be placed accurately on the articulator

while mounting

Causes of errors in occlusion :

Page 11: Clinical and laboratory remoutning

2. Irregularities in Teeth Setting :

• Difficult to set perfectly even contact in teeth arrangement leading to some heavy contacts /pressure

• Wax has certain resiliency ,permits tooth movements to occur when interferences are encountered unlike hard acrylic in denture

• Wax can contract and move ,causing irregularities in teeth arrangement

Causes of errors in occlusion :

Page 12: Clinical and laboratory remoutning

3. Tooth movement while Flasking and Packing

• Tooth movement while de-waxing

• Excessive packing pressures results in, the artificial teeth being forced into the investing plaster

• If the acrylic resin has reached an advanced dough stage

• Normal packing pressures when the investing mix is weakcan break the mould

Causes of errors in occlusion :

Page 13: Clinical and laboratory remoutning

3. Tooth movement while flasking and packing

• Incomplete Flask closure

• If pressure on the flask is released during the curing cycle

• Separation of the two halves of the flask by a layer of excess resin which should have been removed during trial closure of the flask(flash)

Causes of errors in occlusion :

Page 14: Clinical and laboratory remoutning

In spite of taking all due precautions to prevent the errors just described, small occlusal inaccuracies

invariably occur.

These errors can be corrected in the laboratory if a split-cast mounting technique is used.

An average increase in height of 0.5 mm and a shift in tooth contact towards the posterior region

T. Badel et al . Complete Denture Remounting ;Acta Stomatol Croat, Vol. 35, br. 3, 2001

Page 15: Clinical and laboratory remoutning

4. Articulator wear:

• All articulators are subjected to wear and older and more worn the articulator the greater will be the error in occlusion and articulation

• Every piece of mechanical apparatus exhibits some play in its moving part and when this becomes easily detectable, the bearing should be replaced

Page 16: Clinical and laboratory remoutning

5. Other factors • Over heating during polishing procedures

• Inevitable dimensional changes in the denture material during and after polymerisation

• Expansion of the acrylic resin due to water absorption

Shrinkage in denture makes the cuspal position Change in turn increasing VD.

Page 17: Clinical and laboratory remoutning

Occlusal errors can be corrected by:

Direct correction in mouth

Laboratory remounting

Clinical remounting

Page 18: Clinical and laboratory remoutning

Direct Correction in Mouth

1.Articulating paper It will not give an accurate indication of premature

contacts because of resiliency of supporting tissues that allows the denture to shift producing markings which are frequently false

Page 19: Clinical and laboratory remoutning

2. Central bearing plates:• The correlator:

It has a spring loaded central pin It contacts a metal plate in the

vault This,hold the maxillary denture

up and mandibular denture down

At a premature contact,thedentures do not shift because the spring holds the teeth apart

• Coble device: Has a central bearing pin

without spring

Coble device

Page 20: Clinical and laboratory remoutning

3.Occlusal waxes: Adhesive wax is added on the mandibular denture Points of penetration are observed and relieved

• Advantage : Can locate interference in functional movements

• Disadvantage: Can give false reading due to shift of underlying soft tissues

Page 21: Clinical and laboratory remoutning

4.Abrasive pastes:

• Should only be used to refine occlusion after selective grinding on articulator

• Disadvantages: Shifting bases cause premature contacts Cusps maintaining vertical dimension might be destroyed

Page 22: Clinical and laboratory remoutning

When to do Remounts ??

#1Wax—up

If the wax-up occlusion is different in

mouth compared to the

articulator

#2 Processed

After processing the VDO is increased

To get back to the original VDO

#3Delivery

Inaccurate occlusion from

all previous steps not eliminated in

prior remount

Page 23: Clinical and laboratory remoutning

Laboratory Remounting:• Purpose:1. To correct errors in processing

2. To return dentures to the correct vertical dimension

3. To restore centric and bilateral balanced occlusion

Page 24: Clinical and laboratory remoutning

• After processing, but before the removal of the dentures from their casts, they are returned to the articulator.

• This is accomplished by using split-cast mounting techniques, which allow easy location and removal of the cast from its mounting plaster on the articulator.

Split Cast mounting technique:1.procedure for placing indexed casts on an articulator to facilitatetheir removal and replacement on the instrument;

2. the procedure of checking the ability of an articulator to receive orbe adjusted to a maxillomandibular relation record.

Page 25: Clinical and laboratory remoutning

• Split-cast mounting is carried out in the laboratory, by notching the base of the cast and applying separating medium just before articulating the casts.

• The cast is easily separated from the mounting plaster and is flasked after the try-in.

• The cast can be removed from the flask and reattached to the mounting plaster using cyanoacrylate glue.

Page 26: Clinical and laboratory remoutning

Split Mounting Plates

Plexi glass with embedded split mounting plate part

Split mounting plate has 3 metal plates and a pin

Opposing section of split plate attached to the embedded section

Page 27: Clinical and laboratory remoutning

Split Mounting Plates :

Pin removed ; plexiglass detached and other section of split plate attached to cast

Impression is boxed and poured and plexiglass is positioned on it

Page 28: Clinical and laboratory remoutning

Masking tape wrapped around cast on the articulator

The boxing is filled with plaster

Tapered pin is removed and cast seperated

Page 29: Clinical and laboratory remoutning

Procedure for Laboratory RemountingAfter Remounting ,check the incisal pin

and incisal table contact (1-3mm)

Check contacts between heals of the casts and dentures

Place articulating paper ,and gently tap

After the centric check eccentric and protrusive contacts

Adjust these contacts by selective teeth grinding

Page 30: Clinical and laboratory remoutning

Clinical Remounting• It consists of remounting the finished denture on an

articulator by using new inter-occlusal records in the patients mouth

• The purpose of clinical remounting is to accommodate the errors made during centric relation records

Page 31: Clinical and laboratory remoutning

Advantages :1. It reduces patients participation

2. It permits the dentist to see better what he /she is doing

3. It provides stable base ,eliminating the resilient tissues

4. Absence of saliva makes markings more accurate

Page 32: Clinical and laboratory remoutning

Steps for Clinical RemountingI. Registration of centric relationship without tooth contact

II. Lateral or protrusive records

III. Facebow registration

IV. Mounting the dentures

V. Correcting the occlusion by spot grinding

Page 33: Clinical and laboratory remoutning

I. Registration of Centric Relationship without Tooth Contact

• Easily and quickly heat softened

• Records can be modified changed, corrected and verified with comparative ease

• Can distort • Care while handling

Aluwax

• Records of impression plasters are accurate, rigid after setting difficult to handle

• brittlePOP

• Accurate• Stable • Do not need a carrier• Not enough working

time• Resistance to

compression on setting

Silicones

Page 34: Clinical and laboratory remoutning

Remounting at Increased Vertical Dimension or Correct Vertical Dimension??

• When the vertical discrepancy is 2 mm or less, we are often tempted to record the new interocclusal record at the same vertical

• But,when even one tooth makes contact on one side ,it can shift the bases and cause inaccurate records.

Steps for clinical remounting

Page 35: Clinical and laboratory remoutning

• Therefore,

• The remounting records are made at higher vertical dimensions

• i.e :if 2 mm of error + 1-2 mm of material space = 3-4 mm of increased vertical dimension

• This increase should be nullified back,to the original vertical dimension by grinding

Steps for clinical remounting

Page 36: Clinical and laboratory remoutning

• Occlusal errors at wax try-in stage can be corrected by removing the interfering tooth/teeth

• New interocclusal record is then made at the same vertical dimension

• This is a more accurate and physiologically appropriate method

Steps for clinical remounting

Page 37: Clinical and laboratory remoutning

Procedure for Interocclusal Record without Tooth Contact• Two aluwax doubled layered strips (1/2”) are immersed in

water bath of 540c for 30 sec.

• Maxillary denture is seated in mouth, followed by mandibular and stabilized with the index finger over buccalflange area.

• Then the Mandible is guided into CR closing lightly into the wax.

Steps for clinical remounting

Page 38: Clinical and laboratory remoutning

• As contact with the wax approaches the fingers are removed and the patient is instructed to close into the wax until a good index is made

• The imprints of opposing teeth must be crisp and 1mm deep with no penetration of wax record by opposing teeth

If the teeth make contact ,the lower cusp will guide the mandible to the previous wrong position of occlusion ,thus preventing the

desired correction

Steps for clinical remounting

Page 39: Clinical and laboratory remoutning

III. Facebow Registration:• Sufficient amount of wax is adapted on the prongs of

facebow fork

• The patient closes on the fork , facebow is then attached to the fork and related to the condylar heads

Why facebow???A facebow is used to record the relationship of the upper denture to the patient's mandibular hinge axis and transfer this to an articulator, using the hinge axis of the articulator as a reference.

If a facebow is used it allows the teeth to contact by rotating about an arc of closure identical to that of the patient.

A facebow is therefore often used to remount the processed dentures on an articulator for the correction of occlusal errors

Steps for clinical remounting

Page 40: Clinical and laboratory remoutning

IV. Mounting Dentures in Adjustable Articulators• Fabrication of clinical remount casts:

Serve as an accurate, convenient and time saving method of reorienting the completed dentures on articulator for occlusal correction

All undercuts on the tissue surface of the dentures are filled with wet tissue paper, pumice

Steps for clinical remounting

Page 41: Clinical and laboratory remoutning

Fast setting plaster or dental stone is poured into the denture

Steps for clinical remounting

Page 42: Clinical and laboratory remoutning

The maxillary remount cast is attached to the maxillary member of the articulator using the facebow transfer jig

Steps for clinical remounting

Page 43: Clinical and laboratory remoutning

Fabrication of the Facebow Transfer Jig

Attach upper processed denture to the upper

mounting ring

Pour fast setting plaster on the lower ring

Press the teeth in the plaster

Steps for clinical remounting

Page 44: Clinical and laboratory remoutning

Mounting for Clinical Remount The remounting jig and the index are positioned on the

mandibular member of the articulator,

The maxillary denture and the remounting casts are placed in plaster indentation.

The maxillary cast is attached to upper member of the articulator with plaster

The lower denture is attached to the upper denture with help of wax interocclusal records

Steps for clinical remounting

Page 45: Clinical and laboratory remoutning

The condylar guidance can be set with the help of protrusive and lateral records

After the plaster is set,the incisal guide pin is tightened and the record is removed ,there should be no contact of teeth

The incisal pin is then removed and occlusion is set by selective grinding procedure

Steps for clinical remounting

Page 46: Clinical and laboratory remoutning

A simplified Chairside Remount Technique using Customized Mounting Platforms• This clinical remount technique utilizes maxillary and

mandibular CMPs (Customized Mounting Plates) that are fabricated over mounting plates of articulator..

Boxed mounting plates

6.5mm

2 mm 2.5mm

Chauhan et al J Adv Prosthodont. 2012 Aug; 4(3): 170–173.

Page 47: Clinical and laboratory remoutning

Horseshoe shaped grooves

U-shaped positive replica of edentulous ridges with Acrylic (5-6mm)

Page 48: Clinical and laboratory remoutning

Customized mounting platforms secured on articulator

Remount casts obtained in putty impression material.

Mounting done with centric interocclusal record.

Page 49: Clinical and laboratory remoutning

V.Selective Grinding Procedure • In order to produce a satisfactory result, it is important

to carry out grinding in a systematic way to:oThe VD maintenanceo Even distribution of occlusal stresses in CO.o Even distribution of occlusal stresses maintained in

lateral position.

Steps for clinical remounting

Page 50: Clinical and laboratory remoutning

• Hammer and Anvil concept:

As an aid in determining where on the teeth adjustments are to be made

Supporting cusps considered as HammerThe portion of tooth contacted by them as Anvil

The rule is,Adjust the anvil ,NEVER the hammer,thus

preserving our centric stops

The vertical dimension is controlled by these cusps ,therefore they should receive special

consideration

Bailey DCNA April 1995 39(2)

Page 51: Clinical and laboratory remoutning

Grinding in Centric • The first objective is to remove premature contacts in

centric occlusion

• Mark the interfering cusps with articulating paper

• In the retruded contact position there are three types of occlusal errors and each can be corrected by specific grinding1. Any pair of antagonist teeth can be too long and thus

hold other teeth out of contact’2. The lower and upper teeth can be placed almost edge-

to-edge3. The upper teeth can be positioned too buccally in

relation to the lower teeth.

Page 52: Clinical and laboratory remoutning

1. When cusps are too long:1.If the offending cusp makes premature contact in centric

as well as eccentric ground the cusp

2.If the offending cusp makes premature contact in centric only ,deepen the opposing fossa

Page 53: Clinical and laboratory remoutning
Page 54: Clinical and laboratory remoutning
Page 55: Clinical and laboratory remoutning

2. The lower and upper teeth can be placed almost edge-to-edge

Broadnening the central fossae: LINGUAL inclines of the UPPER BUCCAL cusps and

BUCCAL inclines of the LOWER LINGUAL teeth are ground

Narrowing the cusps: Reducing palatal inclines of upper palatal cusps Reducing buccal inclines of lower buccal

Page 56: Clinical and laboratory remoutning

3. The upper teeth positioned too buccally in relation to the lower teeth

The palatal cusp is ground in the palatal direction and the mandibular buccal cusp in the buccal direction so that teeth can enter each other.

Page 57: Clinical and laboratory remoutning

Grinding in Eccentric • Free sliding eccentric movements are important to

Reduce stress on ridges Retention stability

Rule for eccentric grinding is ….Always adjust that which is moving

Page 58: Clinical and laboratory remoutning

On the Working Side there are six types of Occlusal Errors

1. The maxillary buccal cusp and the mandibular lingual cusp are too long

2. The buccal cusps are in contact, but the lingual are not

3. The lingual cusps are in contact, whereas the buccal are not

4. The maxillary buccal or palatal cusps are positioned more mesially from their intercuspal position

5. The maxillary buccal or lingual cusps are positioned more distally from their intercuspal position

6. The teeth on the working side can be out of contact

Page 59: Clinical and laboratory remoutning

1.The maxillary buccal cusp and the mandibular lingual cusp are too long The inner inclines of BUCCAL cusps of UPPER and

LINGUAL cusps of LOWER (BULL) are adjusted

2. The buccal cusps are in contact, but the lingual are not The lingual inclines of upper buccal cusps are ground

Page 60: Clinical and laboratory remoutning

3. The lingual cusps are in contact, whereas the buccal are not Buccal inclines of mandibular lingual cusps are reduced

4.The maxillary buccal or palatal cusps are positioned more mesially from their intercuspal position(MU-DL) Mesial inclines of the UPPER buccal cusps Distal inclines of the LOWER buccal cusps

Page 61: Clinical and laboratory remoutning

5.The maxillary buccal or lingual cusps are positioned more distally from their intercuspal position maxillary cusps distally and on the mandibular cusps mesially

6. The teeth on the working side can be out of contact This is because of intense contact on the balancing side

Page 62: Clinical and laboratory remoutning

Occlusal Errors on the Non-working side• Mandibular buccal cusp are adjusted to reduce the incline of

the part of the cusp that prevents tooth contacts on the working side

Page 63: Clinical and laboratory remoutning

Occlusal Errors in Protrusion• Accoroding to Boucher If the lateral eccentric contacts are

corrected the protrusive grinding also have been accomplished

• However,premature contacts on the incisors are corrected at expense of Incisal edges of lower anteriors

Page 64: Clinical and laboratory remoutning

Perfecting Articulation with Grinding Paste• The main correction of occlusal irregularities must be carried

out using a small mounted abrasive stone in a hand piece to maintain VDO

• A paste of coarse grit carborundum powder mixed with Vaseline/toothpaste is used followed by fine grit carborundum to produce the even occlusal contacts

• The sharp edges occurring buccally and lingualy must be rounded to prevent tongue and cheek irritation

Page 65: Clinical and laboratory remoutning

Eliminating Occlusal Errors in Non-Anatomic Teeth• Maxillary posterior are flattened by sanding on ultrafine

sand paper against a truly flat surface

• After placing on the remount casts and articulation,occlusalcontacts are marked

• Selective grinding is done only on the mandibular teeth

Page 66: Clinical and laboratory remoutning

Occlusal Adjustment in Average Value Articulator• Using a simple hinge articulator is not satisfactory, as lateral

excursions are not possible

• The retruded contact position is recorded intraoral using soft wax

• The upper denture is articulated so that the center pin, touches the mid-line at the upper incisal edge.

Page 67: Clinical and laboratory remoutning

• The lower denture is attached to the articulator ensuring that the occlusal plane is horizontal and parallel to the base of the articulator

• When the plaster has set, the wax is removed between the occlusal surfaces of the teeth and the occlusal adjustment is carried out

Page 68: Clinical and laboratory remoutning

Full Dentures Opposed to Partial Dentures• When maxillary complete dentures and mandibular partial

dentures: Lower impression with the partial denture in situ When casting the impression RPD must be retained in it Similar procedures as previously mentioned are carried out Avoid grinding natural teeth

Page 69: Clinical and laboratory remoutning

Partial Upper an Lower Dentures

• For maxillary and mandibular distal extensions with only anterior teeth remaining previously described procedures can be carried out

• For small partial dentures,the opposing natural dentition is adjusted

Page 70: Clinical and laboratory remoutning

Conclusion • Correct occlusal relationships are a part of the success in

prosthetic treatment for edentulous patients with complete dentures.

• A clinical remount procedure of the finished dentures is a constituent part of prosthetic patient treatment in practice of complete dentures.

• According to a study done by Kamal Shigli et al the results indicated that the laboratory and clinical remount procedures,along with occlusal corrections, reduced the number of areas of tissue irritation, postinsertion visits, pain during mastication and swallowing, and discomfort during mastication, and enhanced the comfort of the patient

Page 71: Clinical and laboratory remoutning

• The clinical remount also maintains the stability of dentures when the mandible is in centric relation position

• Selective grinding helps to remove the occlusal errors in a systematic way

• Occlusion of such dentures is more stable for longer time and with less parafunctional movements

and Hence, a more Satisfied Patient

Page 72: Clinical and laboratory remoutning

References :

• Syllabus of complete Dentures ;Heartwell 4th edition

• Prosthodontic Treatment for Edentulous Patients ;Zarb,Hobkirk et al 13th edition

• Dental Laboratory Procedures volume 1 ;Rudd and Morrow

• Fenn, Liddelow, and Gimsons' clinical dental prosthetics

• Bailey et al Occlusal Adjustment ; DCNA april 1995 ;39(2)

Page 73: Clinical and laboratory remoutning

• Chauhan et al A simplified chairside remount technique using customized mounting platforms; J Adv Prosthodont. 2012 Aug;4(3): 170–173.

• Tomislav Badel et al Complete Denture Remounting Acta StomatolCroat, Vol. 35, br. 3, 2001.

• Kamal Shigli The effect of remount procedures on patient comfort for complete denture treatment J Prosthet Dent 2008;99:66-72

• Lang et al ;Complete Denture Occlusion ;DCNA 2004 48 :641—665

Page 74: Clinical and laboratory remoutning