CLIMAVER A1 APTA - ISOVER Hrvatska · CLIMAVER A1 APTA CLIMAVER self-supporting ducts ... CLIMAVER...

1
CLIMAVER A1 APTA CLIMAVER self-supporting ducts Description ISOVER glass wool panel with excellent fire resistance - does not contribute to the fire at any point. A high-density non- absorbent panel, faced with aluminium, Kraft paper and glass mesh, which acts as a barrier to water vapour thanks to its inner lining, with strengthened black Neto glass-fibre fabric offering high mechanical resistance. Applications Thanks to its excellent thermal and acoustic insulation properties, CLIMAVER A1 APTA is the leading self-supporting duct solution on the market, satisfying the most stringent fire-resistant demands, for installation in: · Self-supporting duct systems for the distribution of air in heating and cooling systems. Technical properties Symbol Parameter Icon Units Value Standard l D Thermal conductivity declared as a function of temperature W/m·K (°C) 0.032 (10) EN 12667 EN 12939 0.033 (20) 0.036 (40) 0.039 (60) Reaction to fire Euroclass A1 EN 13501-1 EN 15715 MU Mineral wool: water- vapour diffusion resistance, m - 1 EN 12086 Z Facing: water-vapour diffusion resistance m 2 •h•Pa/mg 130 EN 12086 MV The vapour diffusion- equivalent air layer thickness, Sd m 100 EN 12086 DS Dimensional stability, De % <1 EN 1604 Airtightness Class D UNE-EN 13403 EN 12237 Pressure resistance Pa 800 UNE-EN 13403 Working conditions: Air speed up to 18 m/s and circulating air temperature up to 90°C. Advantages · Excellent reaction to fire. · High thermal performance. · Maximum watertightness level. · Optimal acoustic environment quality. · Resistant to the most aggressive cleaning methods, UNE 100012. · Exclusive marking out of MTR-cut guidelines. · Fast, simple installation. Maximum on-site efficiency. · Join continuity thanks to the exclusive panel tongue and groove system. · No proliferation of mould or bacteria, EN 13403. · Sustainable product. 100% recyclable. Recycled material > 50%. Installation guide Check CLIMAVER duct installation manual For further information: www.isover.es Frequency (Hz) 125 250 500 1000 2000 4000 Thickness d, mm Practical acoustic absorption coefficient, a P EN ISO 354 / EN ISO 11654 40 0,40 0,70 0,85 0,85 0,90 1,00 Section, S mm 2 Acoustic attenuation on a straight section DL (DB/m)* 200x200 5.82 12.75 16.73 16.73 18.12 21.00 300x400 3.40 7.43 9.76 9.76 10.57 12.25 400x700 2.29 5.01 6.57 6.57 7.12 8.25 For the sound power of a ventilator with a 20,000 m 3 /h, load loss 15mm ca. *Estimate based on the formula: DL = 1,05 • a P , (P=perimeter) 1,4 P S Presentation Thickness d (mm) Length l (m) Width b (m) m 2 / package m 2 / pallet m 2 / truck 40 3.00 1.21 18.15 199.70 1,597 +34 901 33 22 11 www.isover.es [email protected] www.isover-aislamiento-tecnico.es @ISOVERes isoveres ISOVERaislamiento ISOVERaislamiento Saint Gobain Isover Ibérica, S.L. reserves the right to modify, totally or partially and without prior notification, the information contained herein. Likewise, the absence of unintentional errors cannot be guaranteed. 06/04/16 Thickness d, mm Weighted acoustic absorption coefficient, AW, a w Acoustic absorption class Designation code EN 823 EN ISO 354 EN ISO 11654 UNE EN ISO 11654 EN 14303 40 0,90 A MW-EN 14303-T5-MV1 Acoustic trials with plenum: CTA 140003/REV. (1) Weighted acoustic absorption coefficient AW,a w without plenum 0.70 (40mm thickness) CTA 140053/REV-2 and a w without plenum 0,90 (50mm thickness) CTA 140045/REV-2. Certificates

Transcript of CLIMAVER A1 APTA - ISOVER Hrvatska · CLIMAVER A1 APTA CLIMAVER self-supporting ducts ... CLIMAVER...

CLIMAVER A1 APTACLIMAVER self-supporting ducts

DescriptionISOVER glass wool panel with excellent fire resistance - does not contribute to the fire at any point. A high-density non-absorbent panel, faced with aluminium, Kraft paper and glass mesh, which acts as a barrier to water vapour thanks to its inner lining, with strengthened black Neto glass-fibre fabric offering high mechanical resistance.

ApplicationsThanks to its excellent thermal and acoustic insulation properties, CLIMAVER A1 APTA is the leading self-supporting duct solution on the market, satisfying the most stringent fire-resistant demands, for installation in:· Self-supporting duct systems for the distribution of air in

heating and cooling systems.

Technical properties

Symbol Parameter Icon Units Value Standard

lD

Thermal conductivity declared as a function of temperature

W/m·K (°C)

0.032 (10)

EN 12667 EN 12939

0.033 (20)0.036 (40)0.039 (60)

Reaction to fire Euroclass A1 EN 13501-1EN 15715

MUMineral wool: water-vapour diffusion resistance, m

- 1 EN 12086

Z Facing: water-vapour diffusion resistance m2•h•Pa/mg 130 EN 12086

MVThe vapour diffusion-equivalent air layer thickness, Sd

m 100 EN 12086

DS Dimensional stability, De % <1 EN 1604

Airtightness Class D UNE-EN 13403EN 12237

Pressure resistance Pa 800 UNE-EN 13403

Working conditions: Air speed up to 18 m/s and circulating air temperature up to 90°C.

Advantages· Excellent reaction to fire.· High thermal performance.· Maximum watertightness level.· Optimal acoustic environment quality.· Resistant to the most aggressive cleaning methods, UNE 100012.

· Exclusive marking out of MTR-cut guidelines.· Fast, simple installation. Maximum on-site efficiency.· Join continuity thanks to the exclusive panel tongue and groove system.

· No proliferation of mould or bacteria, EN 13403.· Sustainable product. 100% recyclable. Recycled material > 50%.

Installation guideCheck CLIMAVER duct installation manualFor further information: www.isover.es

Frequency (Hz)

125 250 500 1000 2000 4000

Thicknessd, mm

Practical acoustic absorption coefficient, aP EN ISO 354 / EN ISO 11654

40 0,40 0,70 0,85 0,85 0,90 1,00

Section, S mm2

Acoustic attenuation on a straight section DL (DB/m)*

200x200 5.82 12.75 16.73 16.73 18.12 21.00

300x400 3.40 7.43 9.76 9.76 10.57 12.25

400x700 2.29 5.01 6.57 6.57 7.12 8.25

For the sound power of a ventilator with a 20,000 m3/h, load loss 15mm ca.

*Estimate based on the formula: DL = 1,05 • aP

• , (P=perimeter)1,4 PS

Presentation

Thickness d (mm)

Length l (m)

Width b (m)

m2/package

m2/pallet

m2/ truck

40 3.00 1.21 18.15 199.70 1,597

Construimos tu Futuro

+34 901 33 22 11

www.isover.es

[email protected]

www.isover-aislamiento-tecnico.es

@ISOVERes

isoveresISOVERaislamientoISOVERaislamiento

Sain

t G

obai

n Is

over

Ibér

ica,

S.L

. res

erve

s th

e ri

ght

to m

odif

y, t

otal

ly o

r p

arti

ally

an

d w

ith

out

pri

or n

otifi

cati

on, t

he

info

rmat

ion

con

tain

ed h

erei

n. L

ikew

ise,

th

e ab

sen

ce o

f u

nin

ten

tion

al e

rror

s ca

nn

ot b

e gu

aran

teed

. 06/

04/1

6

Thicknessd, mm

Weighted acoustic absorption

coefficient, AW, aw

Acoustic absorption class Designation code

EN 823 EN ISO 354EN ISO 11654 UNE EN ISO 11654 EN 14303

40 0,90 A MW-EN 14303-T5-MV1

Acoustic trials with plenum: CTA 140003/REV.(1) Weighted acoustic absorption coefficient AW,aw without plenum 0.70 (40mm thickness) CTA 140053/REV-2 and aw without plenum 0,90 (50mm thickness) CTA 140045/REV-2.

Certificates

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•Qualité

del'a

irin

térie

ur· Calidad aire interior ·Q

ualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•

Qualitéde

l'air

inté

rieur

· Calidad aire interior ·QualityInterior•