ClimateMaster’s Tranquility 22 - IGSHPA - Down to Earth
Transcript of ClimateMaster’s Tranquility 22 - IGSHPA - Down to Earth
ClimateMaster’s Tranquility 22
1
Raj Hiremath Director of Residential Marketing
• Industry leader since 1950’s
• First to introduce 2-stage 27 EER unit
• First to introduce Outdoor split system with internal pumping
components
• NOW, again first to introduce FULLY communicating controls AND
VARIABLE SPEED internal water flow control options
CLIMATEMASTER
2
Consumers
Comfort
Low operating cost
Environmentally friendly / Efficient
First cost
NEEDS
3
Dealers
Sell-ability / Consumer interest
Reliable
Easy to install
Easy to service
Leverage new, cost effective technology to deliver solutions to satisfy these needs
GEOTHERMAL PRODUCT
INSTALLATION
4
Flow Center
Ground Closed Loop Applications
Water control valve
Flow regulator
Ground Water (open) Loop Applications
• Additional space for flow controller / outside valves
• Fixed speed water flow for two stage units (not optimized)
• Wasted pump energy in fixed speed, mismatched pumps
• Higher cost to achieve 2-stage compressor / Variable speed
airflow
• One-way archaic communication between thermostat and unit
CHALLENGES WITH CURRENT
TECHNOLOGY
5
TRANQUILITY SERIES
Complete product-line
6
FORCED AIR (WATER TO AIR)
HYDRONIC (WATER TO WATER)
Packaged systems
Split systems
Tranquility 27 2-stage
Tranquility 20 1-stage
Compressor section Indoor section
Tranquility Indoor
Tranquility Outdoor
Tranquility Air Handler
Tranquility Cased evap
coil
Medium temperature
High temperature
Tranquility High Temperature
Tranquility Medium Temperature
Tranquility 22 2-stage
TRANQUILITY® 22 DIGITAL
7
TRANQUILITY® 22 DIGITAL
8
• Up to 22 EER / 4.1 COP (qualifies for Federal Tax Credit)
• Competitive pricing
• Compact
• Plug-and-play water flow
• Two-way communication between thermostat and unit
• 2-stage compressor & ECM motor are standard
• Energy Star qualifying warranty
9
• Internal variable speed flow-matches with two stage operation
• Ideal for closed loop applications
• Space / time saving (no external FC)
• Controlled by ΔT
• Flush valves on front of unit inside panel
• Expansion tank to avoid “flat” loops
• Internal motorized modulating valve – matches with two stage operation
• Ideal for open loop applications and multi-unit applications with central pump
• Time saving
• Controlled by ΔT
Internal Variable Speed Flow Controller
Internal Motorized Modulating Valve
Variable speed pump
Motorized modulating
valve
NEW TECHNOLOGY –
PLUG & PLAY
NEW TECHNOLOGY –
COMMUNICATION
4 Wires
“old” C / DXM control “old” non-communicating thermostat
Up to 14 Wires
4 Wires No board
“New” C / DXM2 control “New” communicating thermostat
Fan motor Fan motor
Up to 14 Wires
10
BEFORE NOW
NEW TECHNOLOGY –
COMMUNICATION
Configuration, Monitoring, &
Diagnostics ON
THERMOSTAT
Configure and display operation / fault data at digital thermostat
Integrated ECM control and safeties
Plug & play internal variable speed water flow control enabled
No need to rely on flashing LEDs, guessing dip-switches to diagnose and configure units
Higher intelligence and control
NEW TECHNOLOGY –
COMMUNICATION
• Fan CFM • Water target ΔT
• Water GPM • Water temperature • Air temperature
• Enhanced Fault codes on thermostat
• Fault code history on thermostat
Configure
Monitor
Diagnose
C O N T R O L S T A T U S P U M P O P E R A T I O N
P U M P S P E E D 6 0 %
P U M P W A T T S 1 4 0
F L O W R A T E G P M 7 . 4 ◄ P R E V I O U S
A I R F L O W S E L E C T I O N C F M
H E A T S T A G E 1 6 0 0 H E A T S T A G E 2 7 5 0 A U X I L I A R Y H E A T 8 5 0 E M E R G E N C Y H E A T 8 5 0 C O O L S T A G E 1 5 2 5 C O O L S T A G E 2 7 0 0 C O O L D E H U M 1 4 2 5 C O O L D E H U M 2 5 5 0 C O N T I N U O U S F A N 3 5 0
H E A T O F F D E L A Y 6 0 C O O L O F F D E L A Y 3 0 ◄ P R E V I O U S N E X T ►
Configure - example
Monitor - example
NEW TECHNOLOGY –
COST REDUCTION
25% smaller
Tranquility 20
Full Load EER 20.2 16.2 Part Load EER N/A 22.1 EnergyStar Tier 3 Tier 3
Tranquility 22
Air Coil Water Coil
40% smaller
Tranquility 20 Tranquility 22
Efficiency
Tranquility 20 Tranquility 22
• Small footprint, less height
• Swinging control board
• Attention to access to
components
• Less wires
• Easy disconnect harnesses
EASE OF INSTALL / SERVICE
14
15
TZ 22
Height
Base
TS 20 Comp. A
46.5” 50.5”
48.4” 47.5”
Comp. B
TZ 22 TS 20
26
”
22.4”
30
.6”
25.4”
26
.3”
22.3”
33
.5”
24.25”
SIZE –
3 Ton Dimensional Comparison
Comp. A
Comp. B
FEATURES
16
Product
Comfort Efficiency
EER / COP 2-Stage
Compressor ECM
Standard Filter Size
EnergyStar “Most
Efficient”
Night Setback
Demand Reduction
TZ 22 22.0 / 4.1 Yes Yes 1” Yes Yes Yes
TS 20 20.2 / 4.2 No No 2” No No No
Comp A 17.3 / 3.5 No
Yes 1” No No No
Comp B 19.7 / 4.1 No Yes 1” No No No
FEATURES (cont.)
17
Product
Install and service
Closed Loop Flow Controller
Open Loop Water flow
Control
4-Wires to T’stat
Configure at T’stat
(ΔT+CFM)
Monitor at T’Stat
(GPM, water temp., CFM)
Diagnosis at T’Stat
(Faults/history)
TZ 22 Internal variable speed
Internal mot. modulating
valve
Yes Yes Yes Yes
TS 20 External fixed speed
External No No No No
Comp A External fixed speed
External No No No No
Comp B External fixed speed
External No No No No
TRANQUILITY® 22 DIGITAL
FEATURES AND BENEFITS
18
• Lowest of ClimateMaster families and very competitive against competition
• Smallest footprint in industry • Plug & Play – internal variable speed waterflow • Ease of access to components • Easy monitoring / diagnostics at thermostat
(communicating)
• New electronic monitoring / safeties • Tin plate air-coil / stainless steel drain pan • Variable speed waterflow to better match
demand
• Up to 22 EER / 4.1 COP • Variable speed air & water flow for maximum
efficiency
Price
Efficiency
Easy to Install & Service
Reliability