Cleveland APPLICATION RATE MONITOR VERSION

40
Cleveland Alliances 01361883418 Software rel. 2.3.x APPLICATION RATE MONITOR VERSION

Transcript of Cleveland APPLICATION RATE MONITOR VERSION

Page 1: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

Software rel. 2.3.x

APPLICATION RATE MONITOR VERSION

Page 2: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

2

CONTENTS

● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4 Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5 Positioning..................................................................................................................5 Powersupplyandsensorconnection........................................................................5ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7 Firstswitchingon.......................................................................................................7 Controlsinthemenu..................................................................................................8 Workparameters........................................................................................................9MENU STRUCTURE ....................................................................................................10PRELIMINARY SETUP FOR USE ............................................................................... 11 Flowratealarms........................................................................................................ 11PRELIMINARY SETUP FOR USE ...............................................................................12 Speedalarms...........................................................................................................12 Applicationratealarms.............................................................................................13 Sensors....................................................................................................................14 Flowmetercalibration...............................................................................................15 Speedsensorcalibration..........................................................................................17 Language.................................................................................................................20 Unitsofmeasurement..............................................................................................21 Unitsofmeasurement..............................................................................................22 Displaycontrast........................................................................................................25 Alarmtones..............................................................................................................26 Keytones..................................................................................................................26 Displaysettings........................................................................................................27 Boomlength.............................................................................................................28 Operatingmode.......................................................................................................29 Setupmanagement..................................................................................................30 Testmenu.................................................................................................................32USE ..............................................................................................................................34 Partialtotalizerreset................................................................................................34MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................35 Troubleshooting........................................................................................................35END OF LIFE DISPOSAL ............................................................................................35TECHNICAL DATA ......................................................................................................36 Devicetechnicaldata...............................................................................................36 Setupmenu..............................................................................................................37GUARANTEE TERMS .................................................................................................38

Page 3: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

3

● Legendofsymbols

= Genericdanger

= Warning

This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.

Page 4: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

4

INTRODUCTION

Productdescription

VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.

INTENDED USE

This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith2014/30/UEDirective.

CONTENT OF THE PACKAGE

ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:

Legend:

1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet

PRECAUTIONS

•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.

P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.

Page 5: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

5

RISKS AND PROTECTIONS BEFORE ASSEMBLY

Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.

Positioning

1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.2) Secure VISIO to rail and push down until locked in place.3) Fasten wiring so that it does not interfere with any moving parts.

Powersupplyandsensorconnection

Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.

Wirecolor (powercable) Connectionof

red positive

black negative

green countingabort-groundconnection

yellow countingabort-connection+12VDC

power supplysensors

Page 6: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

6

ASSEMBLY DIAGRAMS

3

4

+12Vdc

GND

Counting abortGround

connection(green wire)

Counting abortConnection

+12VDC

(yellow wire)

Legend:1)Powercable2)Connectioncablefordoublesensor3)Speedsensor4)Flowmeter

Page 7: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

7

CONTROLS IN THE MENU

Firstswitchingon

Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.

Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.

WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.

Page 8: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

8

Controlsinthemenu

Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.

SWITCHING ONAPressfor1second;BPressthekeytoviewthevariousvaluesinextendedmode,inasequence(ondisplaycentralpart).Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion.

SWITCHING OFFAPressfor2seconds.

ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu.

SELECTION AND ACCESS TO MENU ITEMS

APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline);BPresstoopentheselectedmenuitem.

Thethreedotsunderanitemindicatepresenceofanothersetupmenu.

Page 9: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

9

EDITING A VALUEAPresstomovethroughdigits;BPressafewtimestoeditthehighlighteddigit;CPresstoconfirm.Thedisplaygoesbacktopreviouspage;DPresstoexitpagewithoutconfirmingmodification.

Editedvaluemustfallwithintherangeshown.

Workparameters

km/h

0.0

l/ha0.0

0.0

l/min

Fromthemainpage,presskeyfortwosecondstoopenWorkParametersmenu,andsetvaluesforFlowcorrection.

Page 10: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

10

MENU STRUCTURE

Alarms

Min flowrateMax flowrateMin speedMax speedMin App. rateMax App. rate

Sensors

FlowmeterMan. CalibrationAuto calibration

Options

Language

Units of measurem.

Flowrate

VolumelGalm

3

l/minGPMm

3/h

Speed sensorMan. CalibrationAuto calibration

Speed

Length

Km/hMPH

mft

Surface

Application rate

Distance

l/haGPAGPK

KmMiles

haacresKsqft

Display contrast

Alarm tones

Keytones

Data 1Data 2Data 3

Display settings

Volume TOT 1-2Surface TOT 1-2TOT distanceFlowrateSpeedApplication rate

}

Operating mode

Setup management

Save setupLoad setup

Test

Firmware versionBattery voltageDisplayKeysSensors

Boom lenght

0.0

0.0

l/ha

l/min

Km/h

Application rate

Page 11: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

11

PRELIMINARY SETUP FOR USE

Flowratealarms

Setminimumandmaximumflowratethresholdsforalarmmessage.

1)OpenAlarmmenu(Setupmenu>Alarms).

Minimumandmaximumflowratealarmsaresetinthesameway.

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2)Toactivatethealarm,press and

atthesametimeuntilmessage OFF

goesoffandratealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 12: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

12

PRELIMINARY SETUP FOR USE

Speedalarms

Setminimumandmaximumspeedthresholdsforalarmmessage.

1)OpenAlarmmenu(Setupmenu>Alarms).

Minimumandmaximumspeedalarmsaresetinthesameway.

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2)Toactivatethealarm,press and

keyatthesametimeuntilmessage OFFgoesoffandspeedalarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 13: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

13

Applicationratealarms

Setthedesiredalarmdisplaythresholdsforminimumandmaximumapplicationrate.

1)OpenAlarmmenu(Setupmenu>Alarms).

Minimumandmaximumapplicationratealarmsaresetinthesameway.

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2)Toactivatethealarm,press and

atthesametimeuntilmessage OFFgoesoffandapplicationratealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 14: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

14

Sensors

1)OpenSensorsmenu(Setupmenu>Sensors).

Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.

Page 15: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

15

Flowmetercalibration

Duetothedifferentsystemconfigurations(tubes,valves,etc.)ratereadingcouldnotbecorrect.Itisthereforerecommendedtoperformasprayingtest.Ifmeasuredvalueisdifferentfromactualvalue,changetherateconstantthroughanautomaticcalibrationprocedureormanuallycalculatetheconstant.

Automatic calibration

Letapreviouslymeasuredquantityoffluidgothroughthesystemoraquantitythatcouldbemeasuredthroughanothersystem.Thehigherthequantityoffluidusedtoperformthecalibrationprocedure,themoreaccuratethecalibration.

1)Openautomaticcalibrationmenu(Setupmenu>Sensors>Flowmeter>AutoCalibration).Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.2)Startliquidflowinthesystem.Thedisplaywillstartshowingtheincreasingvalueofthemeasuredfluidquantity.Assoonasfluidflowisover,thedisplayedcounterwillstop.

3)NowpressOK.AtthebottomofthedisplayStabilization,messagewillturnonandequipmentwillthenshowthepageontheside.4)Enterpreviouslymeasuredquantityoffluid:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstocompletethecalibrationprocedure,orD)Pressfor1secondtocancelthecalibrationprocedure.

1 Setting the fluid quantity actually passed through flowmeter during the calibrationprocedure.2 Viewingthefluidquantityreadbyflowmeterduringthecalibrationprocedure.

Page 16: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

16

Ifequipmentdoesnotdetectanyflowaftercalibrationisstarted(anddisplayedvalueremains0),pressOKtoquitthecalibrationprocedurewithoutsaving.IfthedevicecontinuestodetectflowafterOKwaspressed,theerrormessageStop flow!.willbedisplayedafterafewseconds.Assoonasflowisstopped,readingwillstabilize,asperstandardprocedure.IncaseVISIOcalculatesavalueoutoftherangethatcanbesetbymeansofthemanualcalibration,thecalculatedvaluewillnotbeset.

Manual calibration

Inordertomanuallysetrateconstant,calculateandsetsuitableconstantusingthefollowingformula:

1)Openmanualcalibrationmenu(Setupmenu>Sensors>Flowmeter>Man.calibration).UnderCalibrationmenu,selectMan.calibration,toviewcurrentlysetconstantvaluebelowtheitem.PressOKtoeditthevalue.

Forflowmeterconstantvalue,refertothecorrespondingmanual.

2)Setflowmeterconstantvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

[quantity measured by equipment]

[actually sprayed quantity]x [constant indicated on flowmeter body]

Page 17: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

17

Speedsensorcalibration

VISIOcalculatestheinformationconcerningthespeedthankstopulsesreceivedbythesensorinstalledonthewheel.Toperformcalibration,proceedasfollows:-Measureastraightpathatleast100m(300feet)long.Thelongerthedistancetraveled,themoreaccuratethewheelconstantcalculation.-Takemeasurementswithtyresattheoperatingpressure.Thistestmustbeperformedonmedium-hardterrain;forapplicationtoverysoftorveryhardterrain,rollingdiametermayvary,leadingtoinaccurateoutputcalculation;whenthisisthecase,repeattheprocedure.Duringthetest,coverthedistancewiththetankfilleduptohalfcapacitywithwater.

Page 18: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

18

Automatic calibration

Calculateandsavethewheelconstantaccordingtotheprocedurebelow:

1)Openautomaticcalibrationmenu(Setupmenu>Sensors>Speedsensor>AutoCalibration).

Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.

Covertherequesteddistance:thenumberofpulseswillincreaseduringthepathandthebottomareawillindicateinstantspeedreading.Stopthetractorattheendofthedistance.

Ifamalfunctionoccurs,themessageCheck sensor!willbeshowninthetoppartofthedisplay.

Press OK tostopthecounting.Thedisplaywillgobacktothepreviousmenuandwillshowtheacquiredvalue.Incaseofmeasurementerrors,orifitisnecessarytostopthecalibration,pressESCfor2secondstoquitthecalibrationprocedurewithoutsaving.Inthiscase,thevaluewillbetheonepreviouslymeasured,orthedefaultvalue.

Page 19: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

19

Manual calibration

Manual calibration allows to enter thewheel constant value calculatedwith thesuitableformula:

Kwheel =distance traveled (cm)

no. of detection points x wheel rpm

<distance traveled> distance expressed in cm covered by thewheel alongmeasurementtravel;

<no.ofmeasurementpoints> numberofmeasurementpoints(e.g.,magnets,bolts,etc.),mountedonwheel;

<no.ofwheel revolutions> number ofwheel revolutions required to travelmeasurementdistance.

Thewheelconstantcanbecalculatedwithagoodapproximationbydetectingthedistancetraveledbythewheelwiththespeedsensor.

1)Openmanualcalibrationmenu(Setupmenu>Sensors>Speedsensor>Man.Calibration).

Covertherequesteddistance.Stopthetractorattheendofthedistanceandcalculatewheelconstant(Kwheel).2)Setwheelconstantvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 20: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

20

Language

Setthedesiredlanguage.

Options

Language

English

Units of measurem.

Display contrast

Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.

PressOK toeditlanguage.

2 1

2

Language

English

ČeskDeutsch

Español

1)Selectalanguagethrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Page 21: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

21

Unitsofmeasurement

Setunitofmeasurementforthevaluesdetectedbythedevice.

Flowrate units of measurement

1)Openinstantrateunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Flowrate).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectflowrateunitofmeasurement.

1)Selectaunitthrough .

2)Press OK tosave,orESC toquitwithoutsaving.

Volume units of measurement

1)Openvolumeunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Volume).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectvolumeunitofmeasurement.

1)Selectaunitthrough .

2)Press OK tosave,orESC toquitwithoutsaving.

Page 22: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

22

Unitsofmeasurement

Setunitofmeasurementforthevaluesdetectedbythedevice.

Speed units of measurement

Openspeedunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Speed).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOKtoselectspeedunitofmeasurement.

1)Selectaunitthrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

Length units of measurement

Openlengthunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Length).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectlengthunitofmeasurement.

1)Selectaunitthrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

Page 23: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

23

Surface units of measurement

Opensurfaceunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Surface).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectsurfaceunitofmeasurement.

1)Selectaunitthrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

Application rate units of measurement

Openapplicationrateunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Applicationrate).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectapplicationrateunitofmeasurement.

1)Selectaunitthrough key.

2)PressOKtosave,orESCtoquitwithoutsaving.

Page 24: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

24

Distance units of measurement

Opendistanceunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Distance).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectdistanceunitofmeasurement.

1)Selectaunitthrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

Page 25: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

25

Displaycontrast

Setdisplaycontrast.

Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setavaluethrough .Everytimeyoupressit,valuewillincreaseby5%up

to100%.Usekey todecreasevalue

by5%.2)PressOK tosave,orESC toquitwithoutsaving.

Page 26: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

26

Alarmtones

Enable/disablethealarmtones.

Openalarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Keytones

Enable/disablekeytones.

1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Page 27: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

27

Displaysettings

Themainpageshowsthedisplaydividedintothreehorizontalparts.Everysectorcanbeassignedthedesiredvalue.

OpenDisplaysettingsmenu(Setupmenu>Options>Displaysettings).Press OK toedittheselectedmenuitem.

1)Selectvaluethrough .

2)PressOKtoedit,orESCtoquitwithoutsaving.

1)Setsectortotherequiredvalue

through .

2)PressOKtosave,orESCtoquitwithoutsaving.Carryoutthesameprocedurefortheother2values.

Page 28: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

28

Boomlength

Setboomlength.

1)Opentheboomlengthmenu(Setupmenu>Options>Boomlength).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2)Setboomlength:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 29: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

29

Operatingmode

Setrequiredoperatingmode.

Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.

1)Selecttherequiredoperatingmode

through .

2)PressOK tosave,orESC toquitwithoutsaving.

WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.

Page 30: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

30

Setupmanagement

VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.

1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).

PressOK toedittheselectedmenuitem.

Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.

1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.

TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.

Page 31: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

31

Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.

1)Selectthedesiredcontrolthrough

key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.

IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.

Page 32: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

32

Testmenu

ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.

Display test

Displaytestchecksthedevicedisplaycorrectoperation.

1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.

Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.

Keys test

Keystestchecksthedevicekeyscorrectoperation.

Openkeystestmenu(Setupmenu>Test>Keys).

Press OK toperformthetest.

1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.

Page 33: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

33

Sensors test

Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.

Opensensorstestmenu(Setupmenu>Test>Sensors).

Press OK toperformthetest.

Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor

through .

2)PressESCtoquit.

Page 34: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

34

USE

Inthe3areasofthemonitor,VISIOwilldisplaytheparameterssetintheDisplaysettingsmenu.

Press keyseveraltimestoviewa

valueinextendedmodeuntilvalueisondisplaycentralpart.

Partialtotalizerreset

Toresetatotalizeryoumustviewitinextendedmode.Presskeyseveraltimesuntilvaluetoberesetisatthecentralareaofthedisplay.

Press keyfortwoseconds.

Totalizerresets.Settingcanorcannotbereset,dependingonsetvalue.

Symbol------indicatesthatflowrateortotalizerexceedmaximumvaluethatcanbedisplayed.Totalizershaveafloatingpointandshowamaximumof4digits.Twodecimalsareshownupto999.99.Onedecimalisshownafterthatand0decimalsareshownwhenvaluereaches10,000.

Page 35: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

35

MAINTENANCE / DIAGNOSTICS / REPAIRS

•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.

Troubleshooting

FAULT CAUSE REMEDY

VISIOisoffordoesnotswitchon

Nopowersupply Checkpowercableconnections

DeviceisOFF PresstheONkey

VISIOshowswrongdata

Wrongsetup Checkdisplayeddatasetup

Sensorfault ContactthenearestAssistanceCenterVISIOfault

Fillingpump(ifany)doesnotstart

PumpStopModulenotpowered

Checkpowersupplyconnection

END OF LIFE DISPOSAL

Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.

Page 36: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

36

TECHNICAL DATA

Devicetechnicaldata

Description VISIO

Display GraphicLCD,128x64pixels,back-lighting

Powersupplyvoltage 9÷16Vdc

Protectionagainstshort-circuit •

Protectionagainstpolarityinversion •

Max.frequency 1.2KHz

Analoginputs 4÷20mA

Digitaloutput-Maxcurrent 100mA

Maximumpowerinput(withnosensorsconnected) 160mA

Operatingtemperature -20°C÷70°C-4°F÷+158°F

Storagetemperature -30°C÷80°C-22°F÷+176°F

Size 126x79x66mm

Weight 245g

Page 37: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

37

Setupmenu

Data Min. Max. Default UoM Notes

Flowmeter Calibration 1 10000 OFF pls/l --

Alarms

Flowrate 0.1 1000.0 OFF l/min. Alarmcanbedisabledbysettingvalueto"OFF"

Speed 1.0 100.0 OFF km/h Alarmcanbedisabledbysettingvalueto"OFF"

Applicationrate 1.0 1000.0 OFF l/ha Alarmcanbedisabledbysettingvalueto"OFF"

Display Contrast 0 100 50 % --

Options

Language - - English -

Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .

Flowrateunitsofmeasurement - - l/min. l/min. Availableunitsofmeasurement:

l/min,GPM,m3/h

Volumeunitsofmeasurement - - l liters Availableunitsofmeasurement:

l,gal,m3

Speedunitsofmeasurement - - km/h km/h Availableunitsofmeasurement:

km/h,MPH

Lengthunitsofmeasurement - - m m Availableunitsofmeasurement:

m,ft

Surfaceunitsofmeasurement - - ha ha Availableunitsofmeasurement:

ha,ac,ksqft

Applicationrateunitsofmeasurement

- - l/ha l/ha Availableunitsofmeasurement:l/ha,GPA,GPK

Distanceunitsofmeasurement - - km km Availableunitsofmeasurement:

km,miles

Page 38: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

38

GUARANTEE TERMS

1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:

- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor

inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;

- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;

- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;

- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning

offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe

organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;

4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.

5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.

6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,

performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.

8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.

Page 39: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418

CONFORMITY DECLARATION

The declaration of conformity is available at www.aragnet.com, in the relevant section.

Page 40: Cleveland APPLICATION RATE MONITOR VERSION

Cleveland Alliances

01361883418 42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]

Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com

D20

287_

GB

-m04

03/2

017