ST-‐6 Maintenance Manual
Air Cap
Liquid Nozzle
Main Unit
Piston Set
Spring
Liquid Adjuster
ST-‐6
Spanner
Parts Structure Content
Daily Cleaning
1.Remove air cap 2.Wipe out the top of liquid nozzle with duster soaked in solvent.
Duster
No dipping whole spray gun in solvent Toothbrush CoLon swab etc. 3.Clean the air cap in solvent
Use soN tool like as toothbrush 1
Periodic Disassemble and Cleaning
For disassembling make sure to use “Lumina” spanner.
Do not use pliers or other tools.
Apply Grease aNer cleaning each parts
1.Grease shaN
2.Grease O-‐Ring
Piston Set 3.Grease Around the wall of piston chamber
4.Grease Inner O-‐Ring When cleaning the parts,
Please remove this O-‐Ring. This O-‐Ring is easy to be damaged
Never hurt this surface. This part is very important for good spray.
ALenWon
2
3
Parts Exchange
Liquid Nozzle
O-‐Ring P-‐3 (Perfluroro)
Needle
O-‐Ring P-‐11 (NBR)
Liquid Nozzle, Needle, and Packing are Consumables. If liquid leak from the top of the nozzle were occurred, replace these parts with new one. Liquid nozzle and needle (or Piston Set) should be replaced all together.
O-‐Ring P-‐3 Exchange
Flathead screwdriver
O-‐Ring P-‐3 Remove O-‐Ring Stopper with Flathead screwdriver. And you will find O-‐Ring P-‐3 pushed in the main unit.
Produced by Fuso Seiki Co.,Ltd. Tokyo, Japan March 2014