CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4...

12
passion for dental research IMPLANT SYSTEM

Transcript of CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4...

Page 1: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

passion for dental research

IMPLANT SYSTEM

Page 2: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

0,9

0,5

1,2

from 0,4 to 1,65

The platform a surface of Platform Switch which varies from 0.4 mm for the plantof 3.5 to 1.65 for the d 6

2,70

mm

2

Page 3: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

3

Osteo-induction surfaceOGI Surfaces (Osteo Growth Induction)

Three-stage production processMechanically controlled stage

Surface conditioning

Decontamination and sterilization

Easy prosthetic systemSingle prosthetic base

Anti-rotation system

Primary functional stabilityNEST SHAPE ® spiral thread

Atraumatic neck

Tissue Friendly ConnectionConical seal connection

Modular transition

No-Risk cervical shoulder thickness

ADV

ADV

ADV

ADV

ADV

ADVANTAGES

Page 4: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

4

1 2 3

1

THREE-STAGE Production Process1

PLANNING

PRODUCTION

QUALITY CONTROL

TREATMENT STAGE

INSPECTION STAGE

CLEANING

PLASMA TREATMENT

STERILIZATION

QUALITY CONTROL

Mechanically controlled stage Surface treatment Decontamination and sterilization

CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37.

All CLC Conic components are made of grade 5 titanium in accordance with UNI 9763-3 ed ASTM F136.

Mechanically controlled stage

Quality control is performed with the help of data collection software and involves

two stages.:

1. statistical check on a set percentage of all parts included in the production process;

2. thorough inspection of the sizing of all the complete pieces in a given batch once

processing is finished.

Highly specialized technical employees are responsible for programming and operating the machinery to achieve CLC

Conic‘high quality standards. The production equipment used by CLC Scientific involves cutting edge CNC machines able

to process on 10-12 axes.

ADV

Page 5: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

5

Upon completion of surface conditioning, CLC Conic implants are subjected to:

1. Double decontamination cycle:

• Cleaning using dedicated solvents;

• Treatment using cold Argon plasma (atomic bombardment with inert gas and magnetic fields inside a

reactor), which guarantees that any contaminants are completely removed.

2. Double sterilization cycle using radiation by an accelerated charge.

Continuous measurement of the parameters of the accelerator and, in particular, the electron beam current,

means that treatment doses are extremely precise, repeatable, homogenous, and intrinsically safe, as

well as environmentally friendly.

2

3

Surface Treatment

TREATMENT Stage CLC Conic Implants are treated in a specialized center that

has been certified for research and processing of implant

material surfaces. This center is equipped with sophisticated

instruments able to determine the topography and cleanliness

of implant surfaces. The surface treatment is strictly governed

by carefully established processes and in accordance with

procedures outlined in ISO9001 and ISO13485.

INSPECTION Stage Production lots are inspected using scanning electron

microscopes with stereoscopic vision and X-ray photoelectron

spectroscopy. The analytical and production teams work

closely together, with a constant exchange of immediate

feedback.

Decontamination and Sterilization

The process validation stages are verified through chemicalphysical characterization tests and cell cultures.

Continuous monitoring of the CLC Conic implant

production processes guarantees:

• packaging is waterproof and impervious to

microorganisms, through contamination trial testing

• the thermoplastic closures in the blister packs have no

cracks or openings, through accelerated aging testing on the

packaging.

Page 6: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

6

During implant insertion, macro grooves collect portions of the bone,

compacting excess bone on the implant alveolar walls and allows excess

blood clots to drain from the alveolus.

They support secondary stability and also serve an anti-rotational function.

Its shape is important during the bone healing process.

The 25 micron double concavity extends the area of bone contact and

influences the primary distribution of newly generated bone.

Allows easy implant insertion and requires no pre-tapping.

Minimizes the bone trauma caused by implant insertion.

Optimal load distribution in the peri-implant bone margin.

NONTRAUMATIC NECK

NEST-SHAPE® thread

Macro Grooves

PRIMARY FUNCTIONAL STABILITY

The form of the Nest-Shape® thread with multi-concavity in the CLC Conic implant makes it

possible to achieve primary functional stability for the osseointegration of the implant.

CLC Conic implant is indicated for D4 bone, for regenerated bone and for immediate loading.

2

Page 7: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

7

OSTEO GROWTH INDUCTION Surface

OGI surgace (Osteo Growth Induction)

It is recommended for most patients:

• in the presence of poor quality bone

• in the case of short implants

Average surface roughness (1.3 μm).Increases the contact area between the implant andbone. Promotes increased osteoblast response.

SANDBLASTING treatment and ETCHING (Sa 1.3 μm)

3

Page 8: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

8

Conical seal connection

The morse taper connection prevents bacterial infiltration and thesubsequent local inflammatory reaction.The absence of movement between the abutment and the implantcontributes to the maintenance of peri-implant bone tissue.

Platform Shifting

The transition between the implant and abutment, from the outside of the fixture to a more central location, offers the ideal shape for tissue adaptation.The crown portion of the implant uses the same surface treatmentfound on the implant as a whole, in order to promote bone growthin this area.

No Risk cervical shoulder thickness

The cervical shoulder induces the diameter transition effect andhelps to minimize mechanical irritation and bacterial infection ofperi-implant tissues.

TISSUE-FRIENDLY connectionThe CLC Conic implant is equipped with a 6° conical abutment-implant connection which helps to preserve

the integrity of the marginal bone tissue and the peri-implant soft tissues.

The cervical shoulder and the single axis of insertion give strength and stability to the implant-abutment structure, providing

optimal absorption of mechanical stress and helping to eliminate the risk of implant fracture. The Conic Connection makes

the CLC Conic implant both mechanically and biologically similar to a mono-block structure, while maintaining the advan-

tages of 2-component systems.

4

Page 9: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

9

The CLC Conic system expands the possibilities for treatment.

Since there is only one connection type, the same prosthetic abutments and the same tools can be used for all implant

diameters. This means the number of components and tools required is greatly reduced when compared to other implant

systems available on the market.

EASY PROSTHETIC system

FIVE IMPLANT DIAMETERSONE PROSTHETIC PLATFORM

We believe that ease of use and ergonomics are the fundamental aspects that determine thesuccess of clinical use of an implant system.

5

� 3,5 mm � 4,0 mm � 4,5 mm � 5,0 mm � 6,0 mm

1,8 mm 2,8 mm 3,3 mm 3,6 mm 4,3 mm

Page 10: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

10

THE RANGE OF IMPLANTS

L 08 mm

L 10 mm

L 12 mm

L 14 mm

L 08 mm

L 10 mm

L 12 mm

L 14 mm

L 06 mm

L 08 mm

L 10 mm

L 12 mm

L 14 mm

L 06 mm

L 08 mm

L 10 mm

L 12 mm

L 14 mm

L 06 mm

L 08 mm

L 10 mm

L 12 mm

L 14 mm

Page 11: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

11

0,5

mm

� 5,5� 5,0� 4,0

HEALING ABUTMENT

IMPLANT DRILLS

Our Easy system provides implantologists with healing abutments of varying diameters and heights to allow

conditioning of the mucosal tissues based on the size of the final prosthetic crown

The special DLC drill coating ( diamond-like carbon) provides long-lasting efficiency and cutting precision.

The low drill tip height minimizes the length of the osteotomy in the proximity of delicate anatomical structures.

Page 12: CLC Scientific - IMPLANT SYSTEM · 2014. 4. 23. · CLC Conic Implants are made of medical grade 4 titanium, in accordance with UNI 9763-3 ed ASTM F37. All CLC Conic components are

“©, A

rsM

edic

aIta

lia, 2

011/

2012

, All

rig

hts

res

erve

d”

Via Vecchia Ferriera, 1836100 Vicenza - Italy

Tel. +39 0444 291168