Siemens Energy & Automation, Inc.Industrial Controls Catalog

Class 11 – 3RV, SMF, MMSManual Control

8/127

Wiring Diagrams

Class 11 - 3RV Signaling Contact for Class 11 - 3RV

3RV1921-1M

Typical Wiring Diagrams—Class SMF

Typical Wiring Diagrams—MMS

06IC08_127-140.qxd 10/5/05 1:44 PM Page 8/127

Page 2: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/128

Wiring Diagrams

Heavy Duty Motor StartersClass 14

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/136 Speedfax 2005

3 P3 Phase and Single Phase Magnetic Starters Ambient Compensated

Single Phase Sizes 00-2 1/2Ambient Compensated3 Phase Sizes 00-2 1/2

Ambient Compensated3 Phase Sizes 3-4

Solid State Overload3 Phase Sizes 00-4

Solid State OverloadSingle Phase Sizes 0-1

Solid State Overload3 Phase Sizes 5-6

� Warning: The ESP100 Starter and Single Phase Motormust be wired with polarity as shown. Neutral and L1wires must be wired as indicated on the drawing.Polarity is indicated by the arrows.

� Full Load Amps (FLA): Adjustment of the ESP100 solidstate overload relay (OL) must be made as follows toaccommodate the single phase motor: For an approxi-mate setting of a single phase motor application,

multiply the motor nameplate FLA by .75 and set thedial on the overload relay (OL) to resulting value.

� The 3 phase for frame size A (without windows) can not be wired for single phase. Use the proper versionfor single phase.

Solid State Overload 3 Phase Wired as 1 Phase���

06IC08_127-140.qxd 12/1/05 3:53 PM Page 8/128

Page 3: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/129

Combination Heavy Duty StartersClass 17, 18

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Inc.talog

Siemens / Industrial Controls Previous folio: 16/137 Speedfax 2005

Wiring Diagrams

REMOVE WIRE "C" IF CONTROL TRANSFORMERIS USED. FOR SEPARATE CONTROL VOLTAGESOURCE, REMOVE JUMPERS "A" AND "B" ANDCONNECT SOURCE TO CONTROL FUSE LINE TERMINALS.

Size 5–6

3 Phase

(OPTIONAL)

X2

SEC

1

XF

4

H2

H3

D

SEC FUSE

CONTROL FUSES

H4

L2

TO SUPPLY

WM

AB

CIRCUIT BREAKERDISCONNECT or

L3

C

T3T2

T2

96

T3M

H1

X1

CONNECTIONS FORALTERNATE

TRANSFORMER

THREE PHASE

V3

2T1

OVERLOAD RELAY

T1

95

L1Size 0–4

he

06IC08_127-140.qxd 11/18/05 12:35 PM Page 8/129

Page 4: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/130

Wiring Diagrams

Reversing Heavy Duty StartersClass 22

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/138 Speedfax 2005

3 P

TO SUPPLY

REMOVE WIRE "C" IF THE CONTACTORCOIL IS TO OPERATE ON A VOLTAGEOTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE.

CURRENTTRANSFORMER(SEE TABLE)

"FWD"CONTRACTOR

MECHANICAL

INTERLOCK

"REV"CONTACTOR

O.L.RELAY

"FWD"CONTACTOR

L1 L2 L3

MOTOR

3 Phase Solid State Overload

Solid State OverloadSizes 0- 1 3/4

Solid State OverloadSizes 5-6

Solid State OverloadSizes 2-4

3 Phase Ambient Compensated Overload

Bimetal Overload Sizes 0-1 3/4

Bimetal OverloadSizes 3-4

Bimetal OverloadSizes 2-2 1/2

Single Phase Ambient Compensated Overload

3 Wire, 2 Pole Sizes 0-1 3/4

06IC08_127-140.qxd 10/5/05 1:30 PM Page 8/130

Page 5: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/131

Combination Reversing Heavy Duty StartersClass 25, 26

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Inc.talog

Siemens / Industrial Controls Previous folio: 16/139 Speedfax 2005

Wiring Diagrams

TO SUPPLY

REMOVE WIRE "C" IF THE CONTACTORCOIL IS TO OPERATE ON A VOLTAGEOTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE.

CURRENTTRANSFORMER(SEE TABLE)

"FWD"CONTRACTOR

MECHANICAL

INTERLOCK

"REV"CONTACTOR

O.L.RELAY

"FWD"CONTACTOR

L1 L2 L3

MOTOR

3 Phase

Size 0–4

X1

SEC

X2

BA

ALTERNATE CONNECTIONSFOR TRANSFORMER

96

XF

H2

H4SEC FUSE

1C

W

D

REVV8

4

67 5

H3

H1

(OPTIONAL)CONTROL TRANSFORMER

(OPTIONAL)CONTROL FUSES

L3L1 L2

DISCONNECT orCIRCUIT BREAKER

TO SUPPLY

3

2

W

9

96

T3

FORV

10

95

T1 T2

OVERLOAD RELAY

T2

T3T1 M

Size 5–6

REMOVE WIRE "C" IF CONTROL TRANSFORMERIS USED. FOR SEPARATE CONTROL VOLTAGESOURCE, REMOVE JUMPERS "A" AND "B" ANDCONNECT SOURCE TO CONTROL FUSE LINE TERMINALS.

06IC08_127-140.qxd 10/5/05 1:31 PM Page 8/131

Page 6: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/132

Wiring Diagrams

Two Speed Heavy Duty StartersClass 30 & 32 Non-Combination and Combination Starters

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/140 Speedfax 2005

1 Winding Constant Horsepower Size 2–4

MOTORT3

T5T6

T4

T2T1

H3

H2

(OPTIONAL)CONTROL TRANSFORMER

D

H1X2

SEC

C XFSEC FUSE

H4 X1

TOGETHERT6

CIRCUIT BREAKER

POSITIONLOW SPEEDHIGH SPEED

L3T3T5

L2T2T4

T1T6

L1T4 T5

96

A

ALL OL'S

LOW

LOW

LOW

OLLOW

HIGH

HIGH

HIGH

HIGHOL

DISCONNECT or

L2TO SUPPLY

L1 L3

L

MOTORCONSTANT HORSEPOWER

95

4

LOW

2

HIGH

HIGH5

3 LOW

7

L

L L

L

T3

T2

T1T5

T4

T5

T6

T3

LOW

L

HIGH6 8

4

5

T2T6

T1

T4

ELEMENTARY DIAGRAM

CIRCUIT BREAKER A B

6

96

T6

OVERLOAD RELAY95

T4

V HI W

T5

96OVERLOAD RELAY

95

V

1

LO W

3

2 7

1 96 CONTROL FUSES(OPTIONAL)

T2T1

V H

8

T3

W

WIRING DIAGRAM

DISCONNECT or

L3TO SUPPLY

L1 L2

X1

A

(OPTIONAL)

B

961C

WIRING DIAGRAM

8V LOW W37

2

OVERLOAD RELAY

H2

H4SEC FUSE

X2H1

H3

D

T3 XFT2T1

M

95 96(OPTIONAL)

CONTROL TRANSFORMER

SEC

CONTROL FUSES

L2 L3L1

CIRCUIT BREAKERDISCONNECT or

TO SUPPLY

WV HIGH

OVERLOAD RELAY

56

4

T5T6 T48

95 96

T6T2

T1

T6T2

T1

T4

T5

T3

T5VARIABLE TORQUE MOTOR

CONSTANT TORQUE MOTOR

T3

T4

L3

HIGH

HIGH

OL

LOW

LOW

LOW

OL

ALL OL'S

HIGH

HIGH

HIGH

HIGH

LOW

T4

T5

T6

T3

T2

T1

ELEMENTARY DIAGRAM

LOW

HIGH

6

7

HIGH

LOW

3

5

2

4

9596

T2T1T5T3L3

T4T2L2

T3

TOGETHER

HIGH

LOW

L2L1

A

T6T1L1

HIGH SPEEDLOW SPEED

POSITION

CIRCUIT BREAKERDISCONNECT or

TO SUPPLY

T1

T6

T3

T5T4

T2

1 Winding Constant Horsepower Size 0–13/4

1 Winding Constant or Variable Torque Size 0–13/4

5

4

TOGETHER

LOWOL

HIGHOL

ALL OL'S

POSITIONLOW SPEEDHIGH SPEED

L3T3T5

L2T2T4T6

T1L1

T4 T5

96

CIRCUIT BREAKER

ALOW

LOW

LOW

HIGH

HIGH

HIGH

DISCONNECT or

TO SUPPLY

L1 L2 L3

MOTORCONSTANT HORSEPOWER

T6

95

4

LOW

2

HIGH

5

3

7 HIGH

6 LOW

T2

T3

T1

LOW

LOWT5

T4

T6

T3

T5T2

T4

LOW

HIGH8

T1

T6

6

ELEMENTARY DIAGRAM

CIRCUIT BREAKER

T2T1

95

T1

T6

T3

T5T4

T2

T3

96OVERLOAD RELAY

V LOW W

95

M

T6 T4 T5

96OVERLOAD RELAY

37

2

V8

HIGH W

C

TO SUPPLY

DISCONNECT or

L1 L2 L3

WIRING DIAGRAM

CONTROL TRANSFORMER

H1

H3

XF

D H2

H4

SEC FUSE

X2

SEC

X1

(OPTIONAL)

(OPTIONAL)CONTROL FUSES1 96

AB

D68785001

D68785002

D68784001

2 W

1 W

06IC08_127-140.qxd 10/5/05 1:16 PM Page 8/132

Page 7: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/133

Two Speed Heavy Duty StartersClass 30 & 32 Non-Combination and Combination Starters

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Inc.talog

Wiring Diagrams

Siemens / Industrial Controls Previous folio: 16/141 Speedfax 2005

2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4

MOTORT3

T6T5T4

T2T1 H2

H3

CONTROL TRANSFORMER(OPTIONAL)

D

H1X2

SEC

9695XF

SEC FUSEH4 X1

TOGETHER

CIRCUIT BREAKER

HIGH SPEEDLOW SPEED

POSITION L3T3T5

T1T6

L1T2T4

L2

T1 T2

96 95

A

ALL OL'S

HIGH

HIGH

HIGH

OLHIGH

LOW

LOW

LOW

LOWOL

L3TO SUPPLY

L1

DISCONNECT or

L2

VARIABLE TORQUE MOTOR

CONSTANT TORQUE MOTOR

T3

HIGH

LOW

4

2

5

3

LOW 7

HIGH H

H

6

T5

T4

T6

H

T2

HT3

H T1

T5

T3

T2

T4

T5

T3

T2

T4

HIGH

H

LOW8

4

5

T6

T1

T1

T6

ELEMENTARY DIAGRAM

CIRCUIT BREAKER A B

6

OVERLOAD RELAY

T6 T4

V HI W

T5

OVERLOAD RELAY9695

V

1

LO W

3

2 7

1 96 CONTROL FUSES(OPTIONAL)

T2T1

V H8

T3

W

WIRING DIAGRAM

DISCONNECT or

L3

TO SUPPLY

L1 L2

C

X2H1

H3MT3

T12T11

T13

A

CONTROL FUSES(OPTIONAL)

B

96C 1

WIRING DIAGRAM

W

T13

V

T11

HIGH

T12

85

47

H4SEC FUSE

SEC

XF

D H2

95 96OVERLOAD RELAY

(OPTIONAL)CONTROL TRANSFORMER

X1

L3L2L1TO SUPPLY

6

3

2

W

T2

V

T1

LOW

CIRCUIT BREAKER

T3

DISCONNECT or

T13

T3

T2T1

95 96

8

LOW

HIGH

OVERLOAD RELAY

T2

T12

T2

T1

T11

T3

T12

T11

T1

L3

OLLOW

OLHIGH

LOW

LOW

LOW

HIGH

HIGH

HIGH

ELEMENTARY DIAGRAM

6

7

LOW

HIGH

5

3

HIGH

LOW

9596

L2T2 T3

L3

T12 T13

ALL OL'S

2

4

T13TWO WINDING MOTOR

L1

L1LOW SPEEDHIGH SPEED

POSITION

A

T1T11

CIRCUIT BREAKERDISCONNECT or

TO SUPPLYL2

1 Winding Constant or Variable Torque Size 2–4

D68784002

D68786001

06IC08_127-140.qxd 10/5/05 1:17 PM Page 8/133

Page 8: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/134

Wiring Diagrams

Heavy Duty Contactors and Reversing ContactorsClass 40, 43

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/142 Speedfax 2005

Sta

3 Phase Contactors—Size 00–4

TO SUPPLY

REMOVE WIRE "C" IF THE CONTACTORCOIL IS TO OPERATE ON A VOLTAGEOTHER THAN LINE VOLTAGE OR ON A SEPARATE CONTROL SOURCE.

CURRENTTRANSFORMER(SEE TABLE)

"FWD"CONTRACTOR

MECHANICAL

INTERLOCK

"REV"CONTACTOR

RELAY

"FWD"CONTACTOR

L1 L2 L3

LOAD

Single Phase Reversing Contactors—Size 00–1P

3 Phase Reversing Contactors—Size 00–4

3 Phase Reversing Contactors—Size 5, 6

3 Phase Magnetic Contactors and Reversing Contactors

Single Phase Magnetic Contactors and Reversing Contactors

Single Phase Contactors—Size 00–4

3 Phase Contactors—Size 5, 6

06IC08_127-140.qxd 2/3/06 8:44 PM Page 8/134

Page 9: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/135

Duplex Heavy Duty ControllersClass 83, 84

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Inc.talog

Siemens / Industrial Controls Previous folio: 16/143 Speedfax 2005

Wiring Diagrams

Standard Duplex Pump Panel (92) Duplex Panel w/o alternator (95)

06IC08_127-140.qxd 2/10/06 1:54 PM Page 8/135

Page 10: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

SiemIndus

8/136

Wiring Diagrams

Duplex Heavy Duty ControllersClass 83, 84

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/144 Speedfax 2005

Duplex Panel with Relay Alternation (93) Duplex Panel with Lead Pump Transfer Switch (94)

Aut

C

L1

T

LLMB

SEKSESSAW

LMB

SEKSESSAW

LMB

SEKSESSAW

*

JUM

PE

R

LMB

SEKSESSAW

LMB

SEKSESSAW

Sta

06IC08_127-140.qxd 2/3/06 9:12 PM Page 8/136

Page 11: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/137

Standard and Reduced Voltage Pump PanelsClass 87, 88

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/145 Speedfax 2005

Inc.talog

Wiring Diagrams

Auto Transformer

OL

2CT

OL

1CT

OL

3CT

CR2

ETM

1LT

4LT

OL

5LT

MR

OL(95) (96)

4FU

MR

1FU

2FU

1S

H1 H4

CPT

X1

TR

3FU

73MR 1S 74

77

OR

DISCONNECT

R

* INTLKMECH

5FU

1S

2S

2S

R MR71 75 76 72

7978

1 3

X2

MR

1

4

L1 L2

2

CIRCUIT BREAKER

2L3

2L2

2L1

0%50%

65%

80%

100%

R

R

R

2S

2S

1L3

1L2

3L3

3L2

L2L1 L3 2S1L1 3L1

T1

1S

1S

T3

T2 MOTOR*

1S

100%

80%

65%

50%

0%

100%

80%

65%

50%

0%

TR

TAS 12

2 3

X2

3

L1 L2

OPTIONAL

(A1) (A2)

(A1) (A2)

(A1) (A2)

(A1) (A2)

CR1

CR1

CR1

NOTC

6 (A2)(A1)

TO SUPPLY

L1LMBLMB

SEKSEKSESSESSAWSAW

LMBLMB

SEKSEKSESSESSAWSAW

LMBLMB

SEKSEKSESSESSAWSAW

L2 L3

SURGE SUPPRESSOR

CONNECTIONS FOR OPTIONAL DEVICES

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

*

*

*

*

**

STOPSTART

HANDOFF

AUTO

AUTOOFF

HAND

OFF ON

1 2 3

1PB 2PB

1 2 3

5

START

2PB

1SS

AUTOCONTACT

1

1

15

AUTOCONTACT

1SS

3

1 31SS

(A1) (A2)

(A1) (A2)

3 4

3 4

1 X2

RUN/ON/

OL TRIPPED9

RUNNING

JUM

PE

R

NOTE ECONNECTVOLTAGEAS SPECIFIEDPER NAMEPLATE

FOR MOTORHP SEECONTROLLERNAMEPLATE

1OFF/STOP

10 X2

FOR STARTERSIZES 1-4, 1CT-3CTARE NOT USED.

SUPPLIED AS REQUIRED

LMB LMB

SEK SEKSES SESSAW SAW

LMB LMB

SEK SEKSES SESSAW SAW

Standard Pump Panel

Part Winding

06IC08_127-140.qxd 2/3/06 9:27 PM Page 8/137

Page 12: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/138

Wiring Diagrams

Reduced Voltage Pump PanelsClass 88

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/146 Speedfax 2005

Par

ETM

1LT

MR

OL

5LT

4LT

CR2

1CT

OL

2CT

OL

OL

3CT

NCTO

1M

1

1

(95) (96)OL

MR

TR

X2

MR(A1)

1FU

2FU

CPT1X1 X1

H1H3 H2

(A2)

X2

3FU

H4

1L1

1L3

1L2

S 57

1M

MR 51 2M52

S(A1)

(A1)

58

1A56 (A1)

(A2)

(A2)

2M

S

*

(A2)

53 (A1)

1A(A2) 54

T3

RES C2M

1A3L3

RES B

T2

2M

1A3L2

T3

T2

Aÿ

INC. LINECUSTOMER'S

OPTIONAL

1L1

CÿBÿ

RES A

2M

1M T1

1A3L1

T1

T6

INTERLOCK

MECH

MR

1L2

S

S

T5

T3

T5

S

T6

T4

T2

T4

S

T1

4FU 5FU5550

2 X2

DISCONNECTOR

CIRCUIT BREAKER

43

2 3

CR1

TR (A2)

CR1(A1)6

1M

1M

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

CONTACT

AUTO

1SS

*1 1SS

OFF

1

HAND

1*

11SS

OFF

**

3

ON

*

CONTACT

3

5AUTO

5

9

RUN/ON/RUNNING

101

1

3

3

OFF/STOPX2

X2

4

4

OL TRIPPED

CONNECTIONS FOR OPTIONAL DEVICES

2

AUTOHAND

*1

1

1PBOFF

STOP

2PB

START

START

22PB

AUTO

3

3

SURGE SUPPRESSOR

(A1)

(A1)

(A2)

(A2)

SUPPLIED AS REQUIRED

PER NAMEPLATEAS SPECIFIEDVOLTAGECONNECT

ARE NOT USED.SIZES 1-4, 1CT-3CTFOR STARTER

4LT

MR

5LT

1LT

ETM

CR2

OL

1CT

OL

2CT

OL

OL

3CT

NCTO

1M

1

1

(95) (96)OL

MRTR

X2

MR(A1)

1FU

2FU

CPT1X1 X1

H1H3 H2

(A2)

X2

3FU

H4

1L1

1L3

1L2

S 56

1M

MR 51 2M52

S(A1)

(A1)

57

(A1)

(A2)

(A2)

2M

S

*

(A2)53 54

T3

2M

T2

1M

2M

1M

T3

T2

Aÿ

INC. LINECUSTOMER'S

OPTIONAL

1L1

CÿBÿ

2M

1M T1 T1

T6

INTERLOCK

MECH

MR

1L2

S

S

T5

T3

T5

S

T6

T4

T2

T4

S

T1

4FU 5FU5550

2 X2

DISCONNECTOR

CIRCUIT BREAKER

43

2 3

T6

T4

T5

(A2)

CR1(A1)

CR1

TR

6

1SS

5

5

2

AUTO

AUTO

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

CONNECTIONS FOR OPTIONAL DEVICES

1

OFF

*

1

HAND

1

1

1SS *

OFF

1SS*

STOP

HAND

*1

1

OFF1PB

2

ON

*3

1OFF/STOP

10 X2

RUNNINGRUN/ON/

SURGE SUPPRESSOR

CONTACT

CONTACT

3

AUTO

START

START

AUTO

2PB

2PB

3

3

1

3

3

(A1)

(A1)

OL TRIPPED9 X2

4

4

(A2)

(A2)

SUPPLIED AS REQUIRED

PER NAMEPLATEAS SPECIFIEDVOLTAGECONNECT

ARE NOT USED.SIZES 1-4, 1CT-3CTFOR STARTER

Wye Delta (Open Transition) Wye Delta (Closed Transition)

06IC08_127-140.qxd 2/3/06 9:45 PM Page 8/138

Page 13: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/139

Reduced Voltage StartersClass 36, 37

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Inc.talog

Siemens / Industrial Controls Previous folio: 16/147 Speedfax 2005

Wiring Diagrams

OL

2CT

OL

1CT

OL

3CT

CR2

ETM

1LT

4LT

OL

5LT

MR

OL(95) (96)

4FU

MR

1FU

2FU

1S

H1 H4

CPT

X1

TR

3FU

73MR 1S 74

77

OR

DISCONNECT

R

* INTLKMECH

5FU

1S

2S

2S

R MR71 75 76 72

7978

1 3

X2

MR

1

4

L1 L2

2

CIRCUIT BREAKER

2L3

2L2

2L1

0%50%

65%

80%

100%

R

R

R

2S

2S

1L3

1L2

3L3

3L2

L2L1 L3 2S1L1 3L1

T1

1S

1S

T3

T2 MOTOR*

1S

100%

80%

65%

50%

0%

100%

80%

65%

50%

0%

TR

TAS 12

2 3

X2

3

L1 L2

OPTIONAL

(A1) (A2)

(A1) (A2)

(A1) (A2)

(A1) (A2)

CR1

CR1

CR1

NOTC

6 (A2)(A1)

TO SUPPLY

L1LMBLMB

SEKSEKSESSESSAWSAW

LMBLMB

SEKSEKSESSESSAWSAW

LMBLMB

SEKSEKSESSESSAWSAW

L2 L3

SURGE SUPPRESSOR

CONNECTIONS FOR OPTIONAL DEVICES

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

*

*

*

*

**

STOPSTART

HANDOFF

AUTO

AUTOOFF

HAND

OFF ON

1 2 3

1PB 2PB

1 2 3

5

START

2PB

1SS

AUTOCONTACT

1

1

15

AUTOCONTACT

1SS

3

1 31SS

(A1) (A2)

(A1) (A2)

3 4

3 4

1 X2

RUN/ON/

OL TRIPPED9

RUNNING

JUM

PE

R

NOTE ECONNECTVOLTAGEAS SPECIFIEDPER NAMEPLATE

FOR MOTORHP SEECONTROLLERNAMEPLATE

1OFF/STOP

10 X2

FOR STARTERSIZES 1-4, 1CT-3CTARE NOT USED.

SUPPLIED AS REQUIRED

LMB LMB

SEK SEKSES SESSAW SAW

LMB LMB

SEK SEKSES SESSAW SAW

Part Winding Auto Transformer

*

06IC08_127-140.qxd 2/3/06 9:31 PM Page 8/139

Page 14: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/140

Wiring Diagrams

Reduced Voltage StartersClass 36, 37

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/148 Speedfax 2005

ETM

1LT

MR

OL

5LT

4LT

CR2

1CT

OL

2CT

OL

OL

3CT

NCTO

1M

1

1

(95) (96)OL

MR

TR

X2

MR(A1)

1FU

2FU

CPT1X1 X1

H1H3 H2

(A2)

X2

3FU

H4

1L1

1L3

1L2

S 57

1M

MR 51 2M52

S(A1)

(A1)

58

1A56 (A1)

(A2)

(A2)

2M

S

*

(A2)

53 (A1)

1A(A2) 54

T3

RES C2M

1A3L3

RES B

T2

2M

1A3L2

T3

T2

Aÿ

INC. LINECUSTOMER'S

OPTIONAL

1L1

CÿBÿ

RES A

2M

1M T1

1A3L1

T1

T6

INTERLOCK

MECH

MR

1L2

S

S

T5

T3

T5

S

T6

T4

T2

T4

S

T1

4FU 5FU5550

2 X2

DISCONNECTOR

CIRCUIT BREAKER

43

2 3

CR1

TR (A2)

CR1(A1)6

1M

1M

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

CONTACT

AUTO

1SS

*1 1SS

OFF

1

HAND

1*

11SS

OFF

**

3

ON

*

CONTACT

3

5AUTO

5

9

RUN/ON/RUNNING

101

1

3

3

OFF/STOPX2

X2

4

4

OL TRIPPED

CONNECTIONS FOR OPTIONAL DEVICES

2

AUTOHAND

*1

1

1PBOFF

STOP

2PB

START

START

22PB

AUTO

3

3

SURGE SUPPRESSOR

(A1)

(A1)

(A2)

(A2)

SUPPLIED AS REQUIRED

PER NAMEPLATEAS SPECIFIEDVOLTAGECONNECT

ARE NOT USED.SIZES 1-4, 1CT-3CTFOR STARTER

4LT

MR

5LT

1LT

ETM

CR2

OL

1CT

OL

2CT

OL

OL

3CT

NCTO

1M

1

1

(95) (96)OL

MRTR

X2

MR(A1)

1FU

2FU

CPT1X1 X1

H1H3 H2

(A2)

X2

3FU

H4

1L1

1L3

1L2

S 56

1M

MR 51 2M52

S(A1)

(A1)

57

(A1)

(A2)

(A2)

2M

S

*

(A2)53 54

T3

2M

T2

1M

2M

1M

T3

T2

Aÿ

INC. LINECUSTOMER'S

OPTIONAL

1L1

CÿBÿ

2M

1M T1 T1

T6

INTERLOCK

MECH

MR

1L2

S

S

T5

T3

T5

S

T6

T4

T2

T4

S

T1

4FU 5FU5550

2 X2

DISCONNECTOR

CIRCUIT BREAKER

43

2 3

T6

T4

T5

(A2)

CR1(A1)

CR1

TR

6

1SS

5

5

2

AUTO

AUTO

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

CONNECTIONS FOR OPTIONAL DEVICES

1

OFF

*

1

HAND

1

1

1SS *

OFF

1SS*

STOP

HAND

*1

1

OFF1PB

2

ON

*3

1OFF/STOP

10 X2

RUNNINGRUN/ON/

SURGE SUPPRESSOR

CONTACT

CONTACT

3

AUTO

START

START

AUTO

2PB

2PB

3

3

1

3

3

(A1)

(A1)

OL TRIPPED9 X2

4

4

(A2)

(A2)

SUPPLIED AS REQUIRED

PER NAMEPLATEAS SPECIFIEDVOLTAGECONNECT

ARE NOT USED.SIZES 1-4, 1CT-3CTFOR STARTER

Wye Delta (Open Transition) Wye Delta (Closed Transition)

06IC08_127-140.qxd 2/3/06 9:46 PM Page 8/140

Page 15: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

Siemens / Industrial Controls Previous folio: 16/150 Speedfax 2005

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Electrically Held, Class LELighting and Heating Contactors

8/141

Wiring Diagrams

20 AMP

30 – 100 AMP

200 – 400 AMP

06IC08_141-156.qxd 12/9/05 2:06 PM Page 8/141

Page 16: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/142

Wiring Diagrams

Lighting and Heating ContactorsMechanically Latched 20 Amp, Class CLM

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/151 Speedfax 2005

2 WIRE CONTROL ACC. 47 ON-OFF (FORM 3) CONTROL ACC. 49

CR2

CR1

3 WIRE CONTROL ACC. 48

2 WIRE CONTROL ACC. 47

SELECTOR SWITCHTYPICAL OFF-ON

OFF

ON

MODULEVOLTAGE

CONTROL

CR2

OFF

4

2

CR1 CR2

3 5

CONTROL

VOLTAGEMODULE

ON

OFF

ON

4

3

2

CR2

CR1

5

ON-OFF

MODULEVOLTAGE

CONTROL3

4

CR

CONTROLREMOTE

OFF

CONTROL

VOLTAGEMODULE

HAND

3

4

CR

AUTO

0

C

ON

L

OFF

L

ON

VOLTAGECONTACTOR CONTROL

CR1

CR1

C

0

OFF

COIL

L

L

VOLTAGE

CONTACT KIT.AUXILIARYCLM4097291REQUIRE (1) EA.PILOT LIGHTS

CR2

CR1

C

0 ON

COIL

L

VOLTAGE

CONTACTOR CONTROLOFF

5

CR

CR

L

ON

C

0

OFF

COIL

L

CONTACTOR CONTROLVOLTAGE

CONTACTOR CONTROL

CR

5

CR

ON

CCOIL

0

OFF

L

L

COMMON OR SEPARATECONTROL LINES

CONNECT TERMINAL 4 TO NEGATIVE (-)

CONT. STATION FOR ACC. 47,48 & 49

CONT. STATION FOR ACC. 48 & 49

* FOR 24 VDC CONTROL MODULES

TERMINAL O ON CONTACTOR

TERMINAL C ON CONTACTOR

CONTACTOR CONTROL VOLTAGE

C

O

5

" "

" "

MODULE CONTROL VOLTAGE *

CONNECTIONS TO CONTROL MODULES

MODULETERMINAL

3

4

2

1

CONNECT TO:

NOT USED

� CoCo

Me

Me

CCOC

CCOC

06IC08_141-156.qxd 2/3/06 9:52 PM Page 8/142

Page 17: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/143

Lighting and Heating ContactorsMechanically Latched 30-400 Amps, Class CLM

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Inc.talog

Siemens / Industrial Controls Previous folio: 16/152 Speedfax 2005

Wiring Diagrams

L

L

� Control relay is required for 2 wire and Hand/Off/AutoControl, as shown in diagram.

Mechanically Latched Type CLM 300 and 400 Amp�

Mechanically Latched, CLM 30–200 Amps�

Connection Diagram for Common/SeparateControl with Momentary Pushbutton orON-OFF Selector Switch CLMOC, CLMOD,CLMOE, and CLMOF

Connection for 2-Wire Control CLMOC,CLMOD, CLMOE, and CLMOF

Connection for Hand/Off/Auto ControlCLMOC, CLMOD, CLMOE, and CLMOF

Connection Diagram for Common/SeparateControl with Momentary Pushbutton orON-OFF Selector Switch CLMOG andCLMOH

Connection for 2-Wire Control CLMOG andCLMOH

Connection for Hand/Off/Auto ControlCLMOG and CLMOH

06IC08_141-156.qxd 2/3/06 9:53 PM Page 8/143

Page 18: Class 11 - 3RV Signaling Contact for Class 11 - 3RV - Siemenscmsapps.sea.siemens.com/controls/icc/06IndControl_ pdfs/06IC_08/08... · Siemens / Industrial Controls Previous folio:

8/144

Wiring Diagrams

Industrial Control Power TransformersClass MT, MTG

SiemIndus

Siemens Energy & Automation, Inc.Industrial Controls Catalog

Siemens / Industrial Controls Previous folio: 16/153 Speedfax 2005

� Includes secondary fuse clips on sizes 50-750VA� Includes secondary fuse clips on sizes 50-500VA� Secondary fuse clips are not included on MTG

transformers.

Voltage LetterA��

When secondary fuse clips are installed,Terminal X1 becomes XF

Voltage LetterD�

When secondary fuse clips are installed,Terminal X1 becomes XF

Voltage LetterG�

When secondary fuse clips are installed,Terminal X1 becomes XF

Voltage LetterJ��

When secondary fuse clips are installed,Terminal X3 becomes XF

Voltage LetterB��

When secondary fuse clips are installed,Terminal X1 becomes XF

Voltage LetterE��

When secondary fuse clips are installed,Terminal X1 becomes XF

Voltage LetterH

Does not include secondary fuse clips

Voltage LetterL

Does not include secondary fuse clips

X1X2

H2H1

24V

380V

Voltage LetterP

Does not include secondary fuse clips

Voltage LetterC��

When secondary fuse clips areinstalled, Terminal X1 becomes XF

Voltage LetterF�

When secondary fuse clips areinstalled, Terminal X1 becomes XF

Voltage LetterI

Does not include secondary fuseclips

Voltage LetterM�

When secondary fuse clips areinstalled, Terminal X1 becomes XF

Formfor O208 V2 Pha2 Phathe o

Hp

1⁄4

1⁄3

1⁄2

3⁄4

1

11⁄2

2

3

5

71⁄2

10

15

20

3 P

Usecurwill manavefactguidpagampNoFor

06IC08_141-156.qxd 10/5/05 10:34 AM Page 8/144